Bakania Depot, Bharat Petroleum Corporation Limited
BPCL Bakania Depot is a POL Location situated on the outskirts of Bhopal on Bhopal-Indore Bypass. Location is inviting bid in tender for Revamping of training Center Bakania is a POL Location situated on Bhopal - Indore on the outskirts of Bhopla. Location is inviting bid in tender for Revamping Training Center
6098
1000392852
Limited Tender
Works
Bakania Depot
7 Oct 2022
16 Sept 2022
6 Oct 2022
16 Sept 2022
6 Oct 2022
16 Sept 2022
16 Sept 2022 - 4 Oct 2022
60 days
S. No. code Description of Item
Dismantling of plain cement concrete of any grade manually/by mechanical means
including disposal of materials ou tside premises to an un objectionable place
or,approved dumping ground of local public Development/Municipal Authority as
per direction of Engineer-in-Charge.Note :The rates are applicable for all
heights/depthsand floors including scaffolding,etccomplete.
Dismantling doors,windows and clerestory windows (steel orwood) shutter
2 9018870 including chowkhats, architrave, hold fasts etc. Complete and stacking within
DISMANTL DOOR/WINDOW
Door (D1) Toilet
Door (D2) Toilet
Supplying and laying vitrified ceramic tiles with water absorption less than 0.08%
and conforming to is 15622 of approval make colour and design at all levels and
locations using approved first quality tiles in flooring with or without spacer, laid
over abedding of cement mortar bed of mix 1:4 to achieve overall flooring
thickness as 50mm and a backcoat of white cement slurry and joints with filled
with white cement mixed with matching pigment complete with all bye works like
covering with plaster of paris curing etc at all leads and lifts and as
perspecification/ instruction of the engineer
VITRIFIED(600MM*600MM*10MM)
Supplying & fixing toughened glass of approved make of following thicknessin
windows, doors, ventilators, partitions
4 9019062 etc. with necessary clips, beadings, EPDM rubber/ neoprene gasket etc. complete
as per the directions of Engineer-in-Charge. Only the clear opening of glass shall
be measured for payment. (Make: Modi, SaintGobain or equivalent)
GLASS FOR DOORS/WINDOWS (5 mm thick)
Supplying & fixing in position FOR SHUTTERS OF DOORS, WINDOWS &
VENTILATORS of aluminium partitions, doors, windows,ventilators, louvres,
fixed glazing, sliding windows, north lighting glazing, aluminium rough ground
etc. witanodised Aluminium (anodised transparent or dyed to required shade
according to IS :1868, Minimum anodic coating of Grade AC 15) , Aluminium
sections,powder coated Aluminium beadings,powder coated Aluminium profile
panelsheets, manufactured to IS 733, IS 1285 and other relevant codes & using
minimum 2mm thick (or as specified) heavy sections from approvedmanufacturer
including cost of supplying required no. of heavy duty stainless steel butt hinges,
pivots, approved door and windowshandles, EPDM Gasket, PVC/Neoprene
Gasket Lining,Stainless steel screws, mastic filling, weather strips, tower
bolts,nuts, washers, rollers etc. as required and as per drawing etc. allcomplete at
5 9018998 all heights and as directed by the Engineer-in-Charge. Therate shall also include
giving a coat of bitumastic paint on thealuminium surfaces in contact with
masonry / concrete and closing thegaps around the frame and the adjoining
surface with approved silicone sealant on both faces to achieve watertightness.
1.No extra payment will be made for all non-aluminium consumable itemslike
screws, gasket, weather strips, PVC/Neoprene lining and butthinges, tower bolts
2.Glazing, Particle Boards, aluminium grills, mesh etc. will bemeasured and paid
separately under relevant item.
3.All fitting shall be of matching anodized aluminiumsections.
The aluminium sections shall be smooth, rust free, straight, mitredand jointed
mechanically wherever required including cleat angles at no extra cost.
VENETIAN BLINDS: Providing and fixing Luxaflex/approved equivalent make
vertical perforated venetian shades blinds of approved shade.The blinds to be
fixed and commissioned as per manufactures specification.The work to be
completed as per satisfaction & approval of the EIC. ( Basic rate of the blinds -
@Rs 1600 Per Smt). Note : All the basic rates mentioned are for reference only.
However, based on the sample approved actual basic rates shall be considered for
any downward/upward variation in rates against the docuemntry proof like
suppliers/manufactures bill/invoice or letter of confirmation of rate from
manufacturer alongwith the final bill. Payment will made for the actual
area covered and not for the overlaps
Supplying and fixing heavy duty double action hydraulic floor springs of
approved make with ISI mark and conforming to IS 6315 , pivoting and all other
arrangements including cost of cutting floors,S.S cover Plates withbrass pivots
7 9019006 etc. complete and other necessary accessories required for the works to facilitate
smooth operation of the
doorshutter at all leads and lifts, all as directed by the Engineer-incharge.Double
action floor spring
8 9019011 AL HANDEL 150mm
AL HANDEL 150mm
Providing and fixing PVC Door Frame of size 50x47 mm with a wall thickness of
5mm(±0.2mm),made out of single piece extruded PVC profile,with mitred cut
joint sand joint with 2 no sof PVC bracket of size 190 mmx100 mm long arms of
crosssection size 35 x15 mm & self driven self tapings crews,the vert ical door
profiles to be reinforced with 40x20 mm M.S.rect angular tube of
9 9019047 mm,including providing EPDM rubber gasket weather seal through out the frame,
including jointing 5 mm PVC frame strip with PVC solvent cement on the back of
the profile.Thedoorframetobefixedtothewallusing 8x100
mmlonganchorfastenerscomplete,allaspermanufacturer’sspecification and
direction ofEngineer-in-charge.
Providing and fixing 37 mm thick factory made PVC door shutter,style sand rails
made of PVC hollow section of size 100 mm x 37mm with wall thickness
2mm(±0.2 mm),withi n builtbead on one side, style sandrailsmiteredcutand joint
at the corners by meansof 2 nos of plastic brackets of size 75 mmx220 mmateach
corner and stain less steels crews,reinforcing the hinge side of style by inserting
PVC profile of size 28 mmx30 mm,with wall thickness2 mm(±0.2 mm).Lock rail
10 9019048 of size
mmx37mm,wallthickness2mm(±0.2mm)willbefixedtotheverticalstyles.Providingw
ith PVCsnapfitbeadsandpanelofsize100 mmx20 mm,andinserting 2nostie barof6
fasteningwithnutsandwasherscomplete,allaspermanufacturer’sspecification and
directionofEngineer-incharge.
supplying and fixing in position seamless false ceiling with 12.5 mmthick Gypboard of
India Gypsum, with standard and approved GI supportingarrangement suspended from
RCC slab with all accessories such as screws,cleats, adjustable suspension rods, runners
and Tees etc., includingmaking suitable openings for air-conditioning grill, light
11 9019094 fittings,troughs etc., and painting false ceiling board with two coats ofapproved make
and shade acrylic/ plastic emulsion paints over and a coatof primer complete with all
bye works at all locations and heightsincluding corbelling/ moulding etc. with extra
runners, using tape etc.to give a seamless look and as per drawings and
manufacturersspecifications and instruction of Engineer Incharge.
Additional False ceiling area(25.7 X 0.5)
Roof Treatment :Providing and laying integral cement based water proofing treatment
for terraces including preparation of surface as required for treatment of roofs,
balconies, terraces etc. consisting of following operations. (a) Applying and grouting a
slurry coat of neat cement using 2.75 kg/m2 of cement admixed with water proofing
compound conforming to IS :2645 over RCC slab including cleaning of surface before the
treatment. (b) Laying broken bricks/brick bats of 25mm to 100mm size with 50% of
12 9018925 cement mortar 1:5 admixed with water proofing compound and providing 20 mm thick
layer of cement mortar 1:5 admixed with water proofing compound to required slope,
treating adjoining walls upto 300 mm height including rounding of junctions of walls and
slabs etc. The cement mortar to be prepared with miminum 30% replacement of OPC
with fly ash by
weight of cement.
Roof (9.85X5.17)
Preparing surface and painting of approved make, shade and quality in all heights of
walls,ceiling, sun sheds fins etc. incl. providing scaffolding,pitting in plaster to be made
good, cleaning with coir brush & sand paper, curing and supply of all materials and
13 9018932 labour complete. The finished surface shall be even and uniform.The application of paint
shall conform to Manufacturer's recommendation and as per the directions of Enginner-
Pasting of Plaster of Paris/putty for uniform finish
14 9018933 2 coats of Anti - Fungal, Anti - Algai Exterior Paint
15 9018953 2 coats of Plastic Emulsion Paint conforming to IS
B Plumbing work
Supplying, fitting and laying concealed HDPE pipes of heavy class conforming to
IS code 4984 with all necessary fittings such as bends, tees,elbows, reducers,
unions, nipples,plugs, clamps,fixtures,etc., inmasonry/ concrete works/under floor
sinsoils etc.including laying inalayer of sand if laidunder floors,necessary painting
16 9019306 with two coats of anti corrosive black bitumas ticpaint overa coat of approved
primer,etc.,complete (including chasing and concealing in walls/floors) at alllead
sand liftsasperdrawings,
specificationsandinstructionsoftheEngineerIncharge.
HDPE PIPES CONCEALED (40mmNB)
C ELECTRIC ITEMS
Low glare recessed fixed downlight in die cast aluminium frame. Anodised
aluminium reflector for high efficiency 15W White Downlight
Low glare recessed fixed downlight in die cast aluminium frame. Anodised
aluminium reflector for high efficiency 15W Neutral White Downlight
Low glare recessed fixed downlight in die cast aluminium frame. Anodised
aluminium reflector for high efficiency 15W Warm White Downlight
POINT WIRING :Supply & Laying Secondary Point Wiring from Switch Board to the
lighting Fixture/Celing Fans Exhaust Fans/Call Bell lamps/ by means of 3 runs of
20 9019143 sq.mm. PVC FRLS 650 Volts/1100 Volts grade ISI approved & ISI marked. PVC Insulated
Stranded copper Conductor through existing recessed/Surface Conduits in an approved
manner. Upto 5 mts
Supply and laying three runs of 2.5 sqmm FRLS PVC copper wire 650 Volts/ 1100 Volts
grade from MCB DB to individual switch boards for lighting and for sourcing 5A
independent switch sockets for raw and ups power in already laid conduits complete
including hook up at both ends
PTWIRE 3run 2.5mm2
Supply and laying two runs of 4 sqmm and one run of 2.5 sqmm FRLS PVC copper wire
650 Volts/ 1100 Volts grade from MCB DB to individual switch boards for sourcing 15A
independent switch sockets for raw and ups power in already laid conduits complete
including hook up at both ends
PTWIRE 3run 4mm2
Supply and laying of CAT6 data cable from HUB to individual RJ 45 sockets
through already laid PVC pipes and connection at both ends using crimping tool
Supply and laying of 5 pair standard telephone cable from exchange KRONE box
24 9019161 to individual telephone sockets through already laid PVC pipes and connection at
TELEPHONE WIRING 5P
Supply and fixing of 25A MCB Swtich Sockets for Power Points with 25A DP MCB and
switch socket with plug top of approved make recessed inside wall including chipping
making good complete
MCB Switch Sockets
Supplying and fixing following modular switch/ socket on the existing modular
plate & switch box including connections but excluding modular plate etc. as
26 9019166 MOD SWITCH 5A
27 9019167 5A Sockets
28 9019168 Fan Regulator electronic
29 9019169 Telephone Socket
30 9019171 TV sockets
31 9019172 15A Switch
32 9019173 15A Socket
33 9019174 Modular 2P MCB upto 16A
Supply, installation, testing and commissioning of concealed type recessed in wall
including chipping and making good MCB Distribution boards of the following
description and approved make double door type with MS sheet doors complete
with board and MCBs as specified:
TPN MCB DB with 40A TPN MCB ELCB/RCCB 100 mA as incomer and 6 Nos
of 6A MCB as outgoing per phase
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
6098.pdf
pdf • 0.42 MB
BUDGETDOC_6098.pdf
pdf • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .