Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.1 LAccepted-AOC MEGHA SADAN GAGANNAGAR CURTI PONDA GOA 403401 | PONDA | SOUTH GOA | GOA | 403401 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹34.0 L+₹3.1 L (10.1%)Rejected-Finance 141 SHANTI NAGAR MODEL TOWN MODEL TOWN PANIPAT HARYANA 132103 | PANIPAT | HARYANA | 132103 | L2 | Rejected-Finance BEING L2 |
Tender Value
₹29.5 L
EMD Value
₹59,000
Closing Date
26 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF BARODA
GE AF BARODA PO DARJIPURA BARODA 390022
PROVISION OF CERTAIN SANCTIONED / MINOR WORKS UNDER AGE E/M AT AF STN BARODA
2022_MES_542799_2
8723/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF BARODA
AS PER TENDER DOCUMENTS AND NIT
3 documents required · 3 mandatory
₹500
GE AF BARODA
₹59,000
Yes
10 Jan 2023
3 Sept 2022
28 Sept 2022
3 Sept 2022
26 Sept 2022
13 Sept 2022
Amount
Supply, install, commissioning and testing factory made (including CPRI approved manufacturer) LT panel box (KIOSK) out door typesize not less then 2000 W x 1500H x 500 D platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with 4 Nos insulated AL bus bars 600 amps rating installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner and individual compartment for MCCB/ volt/Amps meter and 50 x 50 x 6 mm thick angle iron for base frame work having angle iron 4 Nos each Suitable long welded to frame/cubical and grouted in ground upto 0.5 Meter by using PCC 1:2:4 B2 of Suitable size the ground over the ground level upto 1 Mtr height . 2 Nos earth terminal to be welded with feeder piller.The complete feeder pillar box should be anti corrosive coating and finally epoxy polyester powder coating of flint grey shade (RAL-7032) including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 2.5 Sqmm. Front and back opening type for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys reconnecting all existing UG cable with suitable lugs for incoming/outgoing feeders and comprising of all as specified :- (Location Offr Qtr Behind 210 and 214 of Item 01)
Incomer:- (a) MCCB FP 400A 36 kA with Electronic/Microprocessor release with over load Zone of adjustment 0.4 to 1.0 In and Electronic release with Short circuit Zone of adjustment 1.5 to 10.0 Ir. (Adjusted current) with time with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -01 no (b) 4 Nos Aluminium Bus bars of Aluminium strips (50X12mm) having 600 Amp current rating capacity, of suitable size of length as actually required at site for 3 phase and neutral, mounted on epoxy/FRP bus bar insulator complete with nut bolt fixing arrangement complete - 01 set Outgoing :- (c) MCCB FP 250A 36 kA with Adjustable Thermal release for over load 0.64 to 1.0 and Adjustable magnetic release (3.5 to 10.0 In) for Short circuit with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -04 Nos (d) MCCB FP 160 A 36 kA with Adjustable Thermal release for over load 0.64 to 1.0 and Adjustable magnetic release (3.5 to 10.0 In) for Short circuit with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -01 Nos (e) MCCB FP 63 A 16 kA fixed type with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -01 Nos
Supply installed testing and comminsioning , outdoor type,Self standing, double door, front and back openable, APFC panel fabricated (CPRI approved manufacturer) compartmental type with APFC relay 9 stage with heavy duty MPP capacitor bank 80 KVAR (1 KVAR + 2 x 2 KVAR + 1x 5 KVAr+3x 10 KVAr + 2 x 20KVAr with 7% detuned harmonics filter reactor. ) with thyrister control module and MCCB TP of 16 KA of 1.5 time of rating currect of capacitor suitable for each capacitor control and MCCB TPN 160 Amp 16 KA as incomer including control CT & control wiring complete dust and vermin proof double door made out of 3.15 mm CRCA MS sheet outer & inner and individual compartment for MCCB/ volt/Amps meter and 50 x 50 x 6 mm thick angle iron for base frame work having angle iron 4 Nos each Suitable long welded to frame/cubical and grouted in ground upto 0.5 Meter by using PCC 1:2:4 B2 of Suitable size the ground over the ground level upto 1 Mtr height . 2 Nos earth terminal to be welded with feeder piller.The complete feeder pillar box should be anti corrosive coating and finally epoxy polyester powder coating of flint grey shade (RAL-7032) including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 2.5 Sqmm. Front and back opening type for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys having following assessories including control wiring with HR FRLS copper wire complete all as specified (Location :- Qtr 210 and 214 of Item No 02)
(i) Compact modular bolted design, removable side and back panels with option of top and bottom cable entry (ii) Capacitor installed in removable assemblies for ease of operation and maintenance (iii) Incoming of APFC panel of MCCB TPN 160 Amps, 16 KA breaking capacity with high electrolytic grade Aluminium bus bar iof suitable rating (iv) 70 KVAR (1 KVAR + 2 x 2 KVAR + 1x 5 KVAr+3x 10 KVAr + 2 x 20KVAr) with 7% detuned harmonics filter reactor. with thyrister control module and MCCB TP of 16 KA of 1.5 time of rating current of each capacitor suitable for each control . ( each capacitor bank equipped with discharge resister) & 7% detuned harmonics filter reactor. (v) High performance microprocessor based 3 phase APFC relay 9 stage with Auto/Manual Option. (vi) In built 3 phase power analyzer , Amp meter, volt meter and PF meter (each have 1 No) (vii) Capacitor duty thyrister control modules with high thermal current carrying capacity and early make contacts to reduce inrush current for enhancing life of capacitors (viii) Induced air system provided with axial flow fan/ centrifugal fan. (ix) Bottom cable entry system available with front glass for viewing controller and analyzer from front (x) The canopy shall be exposed not less then 15cm both side
Supply, install, commissioning and testing factory made (including CPRI approved manufacturer) LT panel box (KIOSK) out door typesize not less then size 1500 W x 1500H x 500 D platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with 4 Nos insulated AL bus bars 600 amps rating installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner and individual compartment for MCCB/ volt/Amps meter and 50 x 50 x 6 mm thick angle iron for base frame work having angle iron 4 Nos each Suitable long welded to frame/cubical and grouted in ground upto 0.5 Meter by using PCC 1:2:4 B2 of Suitable size the ground over the ground level upto 1 Mtr height . 2 Nos earth terminal to be welded with feeder piller.The complete feeder pillar box should be anti corrosive coating and finally epoxy polyester powder coating of flint grey shade (RAL-7032) including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 2.5 Sqmm. Front and back opening type for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys reconnecting all existing UG cable with suitable lugs for incoming/outgoing feeders and comprising of all as specified :- (Location :- QTr 269 and 280 of Item No 03)
Incomer (a) MCCB FP 250 A 36 kA with Electronic microprocessor release with over load Zone of adjustment 0.4 to 1.0 In and Electronic release with Short circuit Zone of adjustment 1.5 to 10.0 Ir. (Adjusted current) with time with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -01 no (b) 4 Nos Aluminium Bus bars of 500 Amp current rating capacity, of suitable size of length as actually required at site for 3 phase and neutral, mounted on epoxy/FRP bus bar insulator complete with nut bolt fixing arrangement complete - 01 set Outgoing :- (c) MCCB FP 100 A 16 kA with Adjustable Thermal release for over load 0.7 to 1.0 and Adjustable magnetic release (10.0 In) for Short circuit with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -04 Nos
Supply, install, commissioning and testing factory made (including CPRI approved manufacturer) LT panel box (KIOSK) out door typesize not less then 2000 W x 1500H x 500 D platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with 4 Nos insulated AL bus bars 600 amps rating installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner and individual compartment for MCCB/ volt/Amps meter and 50 x 50 x 6 mm thick angle iron for base frame work having angle iron 4 Nos each Suitable long welded to frame/cubical and grouted in ground upto 0.5 Meter by using PCC 1:2:4 B2 of Suitable size the ground over the ground level upto 1 Mtr height . 2 Nos earth terminal to be welded with feeder piller.The complete feeder pillar box should be anti corrosive coating and finally epoxy polyester powder coating of flint grey shade (RAL-7032) including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 2.5 Sqmm. Front and back opening type for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys reconnecting all existing UG cable with suitable lugs for incoming/outgoing feeders and comprising of all as specified :- (Location :- Qtr 277 and 294 of Item 05)
Incomer:- (a) MCCB FP 400A 36 kA with Electronic release with over load Zone of adjustment 0.4 to 1.0 In and Electronic release with Short circuit Zone of adjustment 1.5 to 10.0 Ir. (Adjusted current) with time with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -01 no R Y B ON Trip indication lamp -05 nos Multifunction meter - 01 no (b) 4 Nos Aluminium Bus bars of Aluminium strips (50X12mm) having 600 Amp current rating capacity, of suitable size of length as actually required at site for 3 phase and neutral, mounted on epoxy/FRP bus bar insulator complete with nut bolt fixing arrangement complete - 01 set Outgoing :- (c) MCCB FP 200A 36 kA with Adjustable Thermal release for over load 0.64 to 1.0 and Adjustable magnetic release (3.5 to 10.0 In) for Short circuit with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -04 Nos (d) MCCB FP 160 A 36 kA with Adjustable Thermal release for over load 0.64 to 1.0 and Adjustable magnetic release (3.5 to 10.0 In) for Short circuit with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -01 Nos (e) MCCB FP 63 A 16 kA fixed type with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -01 Nos
Excavation in trenches, n. exc 1.5 Mtr wide and n. exc 1.5 Mtr in depth for foundation/laying of cable and getting out in soft/loose soil complete all as specified and directed
Removing of excavated soil to a distance n. Exc 50 Mtr and depositing where directed at a level n. Exc 1.5 Mtr above the starting point complete all as specified and directed
Returning, filling in including spreading, levelling, watering and well ramming in layers n. Exc 25 cm thick complete all as specified and directed
Supply & spread unwashed dry river sand for sand cushioning and covering the under ground cable in trenches complete all as specified and directed (Note :- Punning thickness shall be measured.)
Supplying and laying un-reinforced precast concrete cable cover, Type 2, flat, size 300mm x 180mm x 40mm complete all as specified and directed
Taking out existing unserviceable LT cable any size complete all as specified and directed
Surface excavation n.exc(not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft / loosesoil complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core complete all as specified and directed
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sq mm 2 core complete all as specified and directed
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables. (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 04 core complete all as specified and directed
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables. (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed
Supply laying testing and comminssioning of XLPE insulated LT U/G cable heavy duty , 1100 volts grade, galvanized wire armoured and PVC sheathed with multistranded aluminium conductor of size 3.5 core 240 Sqmm laid in trenches or fixed on wall (including saddle clip) or poles drawn through pipes complete all as specified and directed
M &L for stones aggregate for loose filling, of gauge 40 mm graded complete all as specified and directed
M&L for providing earthing complete with galvanised steel earth plate electrode 60 x 60cm x 6.0mm thick buried dirictly in ground (Earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level,connected to and including galvanised earth strip 32 X 6mm mm size upto 7.5 meter long by means of bolts,nuts check nuts and washers of all galvanised iron or steel all as shown in electrical plate No.3 of SSR Part-1 and connected to test point including necessary excavation/ earth work in any type of soil/rock strata,funnel with wire mesh and watering pipe(GI,light grade) 20mm dia,PCC pit with 50mm thick PCC cover etc. including testing on completing but excluding GI protection pipe for earthing lead complete all as specified and directed
Taking down carefully aluminium/ copper point wiring (light, fan,socket or power) complete, including fixtures and fittings such as switches, ceiling rosees, pendants, regulators , sockets, light fittings etc., removing materials to stores for keeping in safe custody for taking credit and making good the disturbed surfaces of walls,ceilings etc complete all as specified and directed.
Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceiling and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including modular metal flush box made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of modular white cover plate over sunken box for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washers and making good the disturbed surfaces as per existing for one light/fan point controlled by one switch. Note :- Switch, socket and fan regulators to be measured and paid for separately . PVC Conduit confirming to IS 9537 part I & III
One light/Fan/Exhaust fan point controlled by one switch
Socket outlet point 5 Amp on same board.
Socket outlet point 5 Amp on Independent board.
One bell point controlled by one way switches
Description all as per serial item No. 21.00 above but with 2.5 sqmm cable for 3 pin 15 Amps switch socket outlet (Power point) complete all as specified and directed
Supplying & fixing modular switch, single pole one way 6 Amps, 230 volts AC circuit complete all as specified & directed
Supplying & fixing modular switch, single pole one way 16 Amps, 230 volts AC circuit complete all as specified & directed
Supplying & fixing modular socket outlet, 6Amps, 5 pin, 230 volts AC circuit complete all as specified & directed
Supplying & fixing modular socket outlet, 6-16Amps, 3 pin, 230 volts AC circuit complete all as specified & directed
Supplying & fixing Bell push switch Modular type single pole one way 10 Amp 240 Volts complete all as specified and directed
S&F door bell ding dong, multi tune, Chime and Buzzer complete all as specified and directed
S/F Fan Regulator 5 step Modular type 240 Volts complete all as specified and directed
Supply and fixing lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings,complete all as specified and directed
Supply and fixing Bulb LED 15 Watt suiable for holder complete all as specified and directed
Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and directed
Supply and fixing indoor decorative channel housing fitting slim LED batten 20 Watt with polycarbonate housing and diffuser AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable from ceiling rose to connector of the light, fixing the same with two Nos PVC square box complete including taking down old unserviceable complete all as per specified and directed.
Supply and fixing indoor decorative aesthetically designed Mirror light provided with high output PMMA diffuser for glare free light including LED lamp ( 10 watt) with provision of 2/3 core PVC copper conductor cable from ceilling rose to connector block , fixing the same with two Nos PVC square box complete ncluding taking down old unserviceable complete all as per specified and directed.
Supply and fixing LED security light luminaire 30 watt freedom , pressure die cast aluminum housing, heat resistant glass, IP66 protection, better optics for uniform distribtion complete with all fitting accessories internally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of light including taking down old unserviceable complete all as specified and directed
Supply and fixing in replacement bracket for security light made up of 25mm dia,1.60m long GI pipe, light grade, bent to required length, fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts complete ncluding taking down old unserviceable all as specified and directed.
Supply and fixing in replacement LED light fitting recess mounted/pendent mounting ultraslim LED flat panel 2x2 down light aluminium extruded housing with full opal diffuser IP 20 suitable for perfect lighting condition 36 watt 240 volt, 50 Hz AC complete all as specified and directed
S&F Decorative wall mounting antique brass finish fixture with opal glass diffuser suitable 7.5 watt A60 LED filament Lamp E27 base complete all as specified and directed.
Supply and fix IP 43 VTPN DB With MCCB Incomer Distribution Board Loadline DBs are fitted with Bus Bars, Neutral Links, Blanking Plates 12 way, 415 volts, 50 Hz, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting with one MCCB as incommer 160 Amps complete all as specified and directed . (Note : MCCB SP/TP shall be measured and paid seperately under appropriate items of this schedule
S & F MCB DB 12 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified and directed Note : Copper thimble shall be used for connection of cable .
S & F MCB DB 8 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete ncluding taking down old unserviceable all as specified.
Supply and fix MCB, single pole and neutral link (double pole) 240 volts 40 to 63 Amps capacity B seriesfixed in DB's complete all as specified and directed
Supply and fix MCB, single pole 240 volts 6 to 32 Amps capacity B series fixed in DB's complete all as specified and directed
Supply and fix MCB, single pole 240 volts 40 to 63 Amps capacity B series fixed in DB's complete all as specified and directed
Supply and fixing single pole and neutral enclosure with 2 pin earth industrial plug and socket complete with one MCB SP 25 Amps complete all as specified and directed.
Supply and fix MCB DB 4 way vertical sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting with one MCB as incommer complete all as specified and directed. Note : MCB SP/TPN shall be measured and paid seperately under appropriate items of this schedule . Note : Copper thimble shall be used for connection of cable .
Supply and fix MCB four pole 40 amps FP 415 Volts breaking capacity 20 KA . complete all as specified and directed
Supply and fix MCB, single pole and neutral link 240 volts 6 to 32 Amps capacity C series fixed in DB's. complete all as specified and directed.
Supply and fix MCCB four pole 63 amps FP 415 Volts breaking capacity 20 KA as per IEC 60947-2 . complete all as specified and directed
Supply and fix in repair MCCB four pole 100 amps FP 415 Volts breaking capacity 20 KA as per IEC 60947-2 complete all as specified and directed
Supply and fix IP 43 VTPN DB With MCCB Incomer Distribution Board Loadline DBs are fitted with Bus Bars, Neutral Links, Blanking Plates 04 way, 415 volts, 50 Hz, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting with one MCCB as incommer upto 160 Amps complete all as specified and directed. (Note : MCCB SP/TP shall be measured and paid seperately under appropriate items of this schedule .
Supply and fix MCCB four pole 200 amps FP 415 Volts breaking capacity 35 KA as per IEC 60947-2 complete all as specified and directed
M & L for sub main wiring using two single core 4 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including PVC Conduit or in concealed conduit(as required & directed by Engr-in-Charge)accessories like bends, tee, etc fix on wall and ceiling and connecting to earth dolly and with 4 Sqmm earth wire, PVC insulated & unsheathed complete including taking down old unserviceable complete all as specified and directed Note: (i) Two runs of 4sqmm and one run of 4 sqmm cable and one run of PVC conduit shall be measured as one RM. (ii) Necessary plastering in the disturbed surface of wall and distempering /white washing to match the existing colour shall be included in the unit rate quoted .
M & L for sub main wiring using two single core 6 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including PVC Casing Caping/PVC Conduit or in existing concealed conduit(as required & directed by Engr-in-Charge)accessories like bends, tee, etc fix on wall and ceiling and connecting to earth dolly and including 4 Sqmm earth wire, PVC insulated & unsheathed complete all as specified and directed Note: (i) Two runs of 6 sqmm and one run of 4 sqmm cable and one run of PVC conduit shall be measured as one RM. (ii) Necessary plastering in the disturbed surface of wall and distempering /white washing to match the existing colour shall be included in the unit rate quoted .
All as above item No- 54.00 but using 4 Sqmm cable for phase and neutral and 2.5 Sqmm for earth complete all as specified and directed Note: (i) Two runs of 4 sqmm and one run of 2.5 sqmm cable and one run of PVC conduit shall be measured as one RM. (ii) Necessary plastering in the disturbed surface of wall and distempering /white washing to match the existing colour shall be included in the unit rate quoted .
Earthing complete with galvanised steel earth plate, electrode, 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts, & washers of GI as shown in electrical plate No. 3 of SSR Part-I. Connected to earthing test point all as specified and including necessary earth pit PCC 1:3:6 chamber be 50mm thick PCC 1:2:4 chamber cover with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 15mm dia unto 7.5 from the earth plate electrode & refillling of soil etc including necessary excavation & earth work in any strata and PCC chamber including demolishion of old and unsv existing earth pit and removing from site complete all as specified and directed
Supply and fixing exhaust fan with louvers of size 450 mm sweep, 900 RPM 230 volts single phase AC supply complete with, bolt, nuts and washers, suitably embedded in the wall including making suitable opening and provisioning of flexible cord copper of size 23/0.0076 from ceiling rose to exhaust fan for giving connection complete all as specified and directed
S&F Ceiling fan 1200 mm sweep 5 Star Rating wirh BLDC technology 32 watt with dust resistant including Remot controlled regulator, connecting wire PVC insulated flexible 0.5 sqmm copper conducter canopy set, down rod, Shackle Kit, and Twisted Wire complete all as specified and directed
Supply, Install, Testing and Commissioning of 'Solar Hot Water System' (Flat Plate Collector) based on indirect transfer of heat of capacity 200 LPD including power supply backup with 4 kw heater following accessories:- (i)Solar flat plate collectors shall be constructed strictly as per norms of Ministry of Nonconventional Energy Sources (MNES), Govt. of India and BIS specifications. (ii)Collector Support Structure :- The support structure for the collectors shall be of MS angle of size not less than 40x40x6 mm. The structure shall be provided with suitable flat iron sections to fix collectors on structure and to prevent from uprooting, during heavy winds. (iii)Hot Water Storage Tank along with structure and insulation:-Tank shall be of the full capacity as per the system. Tank shall have thermal stratification to prevent mixing of cold and hot water. The tank shall be made of 3.15mm thick stainless sheet SS-304.Hot water tank shall be insulated with 100 mm thick Rock Wool of density 48 Kg/m3 insulated with using chicken wire mesh and vapour barrier. On the top of the insulation, aluminium cladding with 26 SWG aluminium sheet. (iv) Coldwater Tank capacity 500 Ltr along with supporting structure and tapping of water connection from nearby tank including 20mm pipe and gate valve as per manufacturer recommendation. (v) Hot water pipe duly insulated with glass wool and aluminium cladding 15 mm bore length from Hot water tank to toilet with provisioning of 2 Nos hot water tabs
Supply and fix in repair GI tubing light grade 50 mm for protection of cable at wall/trench with fixing accessories as directed of following size. Note Unit rate include Cutting on Road or walls will be Plaster with pcc 1:2:4 and making good the Surface as required at site complete all as specified and directed
Material and labour for boring of hole to cross roads/ hard cemented surface for insertion of 50 mm dia G I pipe for laying of cable complete all as specified and directed
Supply and fix Flood Lights 50 watt with best in class design & Robust heat sink along with class leading IP, IK & Surge protections for long lasting performance including all fitting accessories complete all as specified and directed
S & F FRP Junction box of size 250mm x 200mm x 105mm and in any position on poles including all fitting accessories complete all as specified and directed
S/F Wall fans of 400 mm sweep with Hi-speed, low noise level with all fitting accessories complete all as specified directed.
Supply and install split Air conditioning unit (White), inverter type with split units indoor/outdoor with insulated copper tubing, Copper condenser coil, precision cooling technology,dual rotor inverter technology, R32 refrigerant, Brushless DC motor, 4-in-1 Convertible Cooling, Magic Display ecofriendly refrigerent, copper bound rotary compressor complete with cordless remote control unit, Stand for outdoor unit and dust filter for better indoor air quality 5 star rating and of capacity 2 TR complete all as specified and directed
Supply and fix voltage stablizer for automatic operation single phase naturally air cooled indoor type having low and high voltage cut-off protection, inbuilt thermal protection & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy +/- 2.5% and of capacity of 5 KVA wall mountable.complete all as specified and directed.
M & L for shifting of 40 KVA DG set from Arjan Hall Darjipura To BOCC Harni(approx distance 6 KM) with using suitable transportation and crane or loading unloading complete all as specified and directed.
Construction of DG set plateform for 40 KVA DG set , of size 4000mm x 3000 mmx1200mm above ground with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate 150 mm thick, 150 mm wide off sets allround over 100 mm thick hard core, brick masonry walls built in CM 1:6, 300 mm thick PCC 1:2:4 Type B1 coping finished even and smooth on top of floor including excavation, earth work insoft soil, including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed
Supplying, erecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 mtrs long) including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide including taking down old unserviceable PCC poles of any type complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
M&L PCC 1:4:8 type D2 using 40 mm graded stone aggregate for filling & foundation of pole & mass complete all as specified and directed
M&L PCC 1:3:6 type C 2 using 40 mm graded stone aggregate for filling & foundation of pole & stay complete all as specified and directed
M&L PCC 1:2:4 type B1 using 20 mm graded stone aggregate for coping of pole complete all as specified and directed
Chanda Construction Co.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .