| 1 | L1₹39.2 LAccepted-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹40.2 L+₹94,833.08 (2.42%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹40.8 L+₹1.6 L (4.06%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹41.2 L+₹2.0 L (4.99%)Rejected-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹44.4 L+₹5.2 L (13.3%)Rejected-AOC | L5 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | pavan putra enterprises L2 | RAGHU RAMA PANDA L4 | M/S SRI VENKATA BHAVANI CONSTRUCTIONS L8 | RATNA ENTERPRISES L5 | NEELESH ENTERPRISES L9 | RAJASHEKHAR ENTERPRISES L7 | Sri balaji Constructions L6 | ESWAR ENTERPRISES L3 | PRASAD INFRAS L1 | D NARAYANA REDDY CONSTRUCTIONS L10 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| .01SCHEDULE 'A' PART-I: B/R WORKS | |||||||||||||
| 1.00 | Excavating over areas, n exc 1.5 m deep and getting out soft and loose soil Complete all as specified and directed. | 450.3 | Cum | 280 ₹1,26,084 | 205 ₹92,311.5 | 300 ₹1,35,090 | 279 ₹1,25,633.7 | 250 ₹1,12,575 | 285 ₹1,28,335.5 | 300 ₹1,35,090 | 250 ₹1,12,575 | 200 ₹90,060 Lowest | 300 ₹1,35,090 |
| 2.00 | M & L for providing plain cement concrete, type D-2, 1:4:8 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. | 20.7 | Cum | 5,600 ₹1,15,920 | 3,499 ₹72,429.3 Lowest | 3,900 ₹80,730 | 4,500 ₹93,150 | 4,200 ₹86,940 | 4,600 ₹95,220 | 4,500 ₹93,150 | 3,780 ₹78,246 | 3,800 ₹78,660 | 5,100 ₹1,05,570 |
| 3.00 | M& L for RCC M-30 design mix Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses etc Complete all as specified and directed. | 41.4 | Sqm | 8,000 ₹3,31,200 | 7,009 ₹2,90,172.6 Lowest | 8,000 ₹3,31,200 | 8,500 ₹3,51,900 | 8,300 ₹3,43,620 | 8,200 ₹3,39,480 | 8,500 ₹3,51,900 | 7,650 ₹3,16,710 | 8,500 ₹3,51,900 | 8,300 ₹3,43,620 |
| 4.00 | M& L for RCC M-30 design mix Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete Complete all as specified and directed. | 36.8 | Cum | 7,500 ₹2,76,000 | 7,009 ₹2,57,931.2 | 8,100 ₹2,98,080 | 8,500 ₹3,12,800 | 8,600 ₹3,16,480 | 8,300 ₹3,05,440 | 8,700 ₹3,20,160 | 7,650 ₹2,81,520 | 6,500 ₹2,39,200 Lowest | 8,500 ₹3,12,800 |
| 5.00 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter. Complete all as specified and directed. | 46 | Sqm | 300 ₹13,800 | 529 ₹24,334 | 300 ₹13,800 | 290 ₹13,340 Lowest | 460 ₹21,160 | 400 ₹18,400 | 450 ₹20,700 | 390 ₹17,940 | 300 ₹13,800 | 450 ₹20,700 |
| 6.00 | Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter | 414 | Sqm | 480 ₹1,98,720 | 529 ₹2,19,006 | 390 ₹1,61,460 | 350 ₹1,44,900 Lowest | 480 ₹1,98,720 | 450 ₹1,86,300 | 500 ₹2,07,000 | 450 ₹1,86,300 | 400 ₹1,65,600 | 500 ₹2,07,000 |
| 7.00 | Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for wall ,footing, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips Complete all as specified and directed. | 8,856.69 | Kg | 90 ₹7,97,102.01 | 97 ₹8,59,098.83 | 125 ₹11,07,086.13 | 130 ₹11,51,369.57 | 120 ₹10,62,802.68 | 110 ₹9,74,235.79 | 105 ₹9,29,952.35 | 95 ₹8,41,385.46 | 85 ₹7,52,818.57 Lowest | 120 ₹10,62,802.68 |
| 8.00 | M&L for 25mm thick Cement concrete type B-1, 1:2:4 (12.5mm graded aggregate) as in surface channel finished even and smooth with using extra cement all as specified and directed. | 69 | sqm | 180 ₹12,420 | 133 ₹9,177 Lowest | 150 ₹10,350 | 150 ₹10,350 | 185 ₹12,765 | 160 ₹11,040 | 150 ₹10,350 | 150 ₹10,350 | 150 ₹10,350 | 165 ₹11,385 |
| 9.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. | 88.53 | Cum | 130 ₹11,508.9 | 97 ₹8,587.41 | 90 ₹7,967.7 | 140 ₹12,394.2 | 85 ₹7,525.05 Lowest | 110 ₹9,738.3 | 95 ₹8,410.35 | 90 ₹7,967.7 | 100 ₹8,853 | 115 ₹10,180.95 |
Tender Value
₹46.1 L
EMD Value
₹92,300
Closing Date
10 Dec 2025, 6:00 pmClosed
Garrison Engineer Naval Depot
Garrison Engineer Naval Depot Industrial Estate Post 104 Area Visakhapatnam 530007
PROVISION OF RAIN WATER DRAIN FROM PTW 1OUTFITTING WORKSHOP TO SOUTH SIDE PERIMETER WALL AT INS VISHWAKARMA, PROVISION OF INTRERNAL ROAD CMT B I STOREHOUSE BUILDING NO P129 TO WALK IN COLD AND COOL ROOM BVY V AND SOME MINOR WORKS UNDER GEND VISAKHAP
2025_MES_740363_1
8518/GEND/E8
Open Tender
Civil Works
Item Rate
180 days
Visakhapatnam
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ND VISAKHAPATNAM
₹92,300
Yes
24 Mar 2026
18 Nov 2025
12 Dec 2025
18 Nov 2025
10 Dec 2025
3 Dec 2025
Amount
SCHEDULE 'A' PART-I: B/R WORKS
Excavating over areas, n exc 1.5 m deep and getting out soft and loose soil Complete all as specified and directed.
M & L for providing plain cement concrete, type D-2, 1:4:8 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M& L for RCC M-30 design mix Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses etc Complete all as specified and directed.
M& L for RCC M-30 design mix Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete Complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter. Complete all as specified and directed.
Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter
Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for wall ,footing, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips Complete all as specified and directed.
M&L for 25mm thick Cement concrete type B-1, 1:2:4 (12.5mm graded aggregate) as in surface channel finished even and smooth with using extra cement all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.
Removing excavated material outside of MOD land and depositing where directed at a level n exc. 1.5 m above the starting point in soil
Rolling and consolidating formation surfaces in cutting using power roller of capacity exceeding 8 tonnes and n.exc 12 tonnes all as specified and as directed.
M&L 200 mm thick (compacted thickness) GSB Kankar or laterite, spread, rolled and consolidated togradient and camber required Complete all as specified and directed.
M&L 150 mm thick Soling (or sub base) with broken boulders or quarried stone, inter stices filled, surface formed and rolled and consolidated to required gradient and camber all as specified and as directed.
M&L Cement concrete work in pavement/ hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre thickness of concrete 20 cm Complete all as specified and directed.
M&L for Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing com?pound, Grade ‘A’
M&L Forming Construction joint 30mm deep x 10mm wide filled with sealing compound of grade B
Removing excavated material exc 250m but n exc. 500m and deposting where directed Complete all as specified and directed
S&F mild steel turbo ventilators of following specifications fixed to existing Galvalume roof sheet of height 15m including cutting to existing roof sheet , scaffolding and neceaasary safty arrangements.Specifations of turbo ventilators: (i) Ventilators throat diameter=24inch (ii) Ventilators outer diameter=30inch (iii) Bottom Ring width=100mm (iv) Mounting base plate size=1650mm.
Dismantling of pain or corrugated steel sheeting any gauge thickness including Nainital or similar pattern roof covering complete all as specificed and directed.
S&F for 0.50 mm thick pre-painted corrugated/'Z' profile galvalume roofing sheets as in roofing (in any loaction and any type) having high strength steel with minium 550 Mpa strength hot dip coated with aluminium zinc alloy (55% aluminium and 45% zinc) pre-painted with primer cost of 5 micron and coated with Silicon modified polyster coating of 20 micron and alkalyed coating of 10 micron on reverse side. End rib, side over lap and over lap and over lap of sheets shall be designed for anti capillary activities to avoid any seepage of water through lateral overlap as per manufacturer's instructions including fixing with self drilling and self tapping screws 0.5mm dia full threaded,all Kautex coated and fitted with EPDM washers in stainless steel. The screw shall be coated with anti-corrosive substance to ensure longer life and shall be fixed using drill guns for lead proof installation. Screws shall of "HILTI" make T&P to reach the roof to fit the sheets to be arranged by the contractor and complete all as specified.
SCHEDULE 'A' PART-II: E/M WORKS
Supply, install, commissioning and testing of Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300V to 480 V with output voltage stabilized at 415V with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 15 KVA, complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core, complete all as specified and directed.
Supply and fixing of MCB 63 Amp, 415 Volt, TP / TPN, breaking capacity 10 KA 'C' series, complete all as specified and directed.
Excavation in trenches not exc.1.5m wide and not exceeding 1.5m in depth and getting out in hard/dense soil for laying of cable complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick complete all as specified
Removing excavated surplus soils meterial not exc.50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified.
Material and labour for natural river sand as cushioning of cables, including spreading and punning down complete all as specified and directed by Engineer in charge. Note : punned thickness shall be measured for payment purpose
Supply and laying in trenches bricks common burnt clay building brick , sub class B designation 75 complete all as specified & directed
Supply and laying GI tubing lingh grade 40mm in trenches complete all as specified & directed by Engr in charge
Earthing complete with copper plate electrode 60×60cm×3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to 20x3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion, complete all as specified and directed.
Supplying, installing testing and commissioning of Analogue Addressable type Single Loop Fire Alarm Control Panel with 99 detectors & 99 Modules & up to 200 Detectors and Modules per each loop, expandable Up to 1000 fire detection zones, with UL/ULC/ LPCB/ FM listed and complying with BS EN 54 Parts 2 and 4 along with Network interface Card and Lead Acid Battery backup for 08 Hours normal operation and 15 minutes alarm operation, the control panel, battery charger including provision of protective cover as and where required and taking down existing old panel of any description and type complete all as specified and as directed and consistiong of lthe following features:-
Note: The rate quoted shall also deemed to include for the following provisions also:- [i] Supply and installation of Batteries 12v 18/07 Ah - 02 Nos [ii] Supply and installation of 24 volt Fault Torrent Network card/ OLYNET/ ONERING with bulit in diagnostics and is fully monitored for both short and open circuit faults between nodes installed in fire alarm panel with maximum 200 Network nodes. [iii] Fire detection and alarm system connected with Compatible GSM/PSTN auto dialer alongwith activated Sim for easy communication with pre recorded messages to stored phone numbers - 1 Set Make: Compatible with Honeywell, Notifier, Apollo Discovery, Argus Vega, Hochiki ESP and Nittan Evolution protocols
Supplying, installing and testing of Multisensor Detector with self built intelligence Complying with and type certified to EN 54 and conforming to IS - 11360 comprising of optical smoke and thermistor temperature sensors, to give both combined signal as well as a separate heat signal for improved false alongwith isolator modules as required, provided as per area requirment below or above the false ceiling including taking down old detectors of andy descrition and type complete all as specified and as directed and with following specifications:-
Communications protocol: 5-9V peak to peak Operating voltage: 17-28V DC Quiescent current: 500µA average 750µA peak Power-up surge current: 1mA Maximum power-up time: 10s Alarm LED current: 3.5mA Remote LED current: 4mA at 5V (measured across remote load) Clean air analogue value: 23 +4/-0 Alarm level analogue value: 55 Alarm indicator: 2 colourless Light Emitting Diodes (LEDs); illuminated red in alarm Optional remote LED Dimensions: 100mm diameter 50mm height 58mm (height in base) Weight: Detector: 105g Detector in base: 160g Materials: Housing: White polycarbonate V-0 rated to UL94 Terminals: Nicket plated stainless steel Smoke element only: Chamber configuration: Horizontal optical bench housing infra-red emitter and sensor, arranged radially to detect forward scattered light Sensor: Silicon PIN photo-diode
Supplying, installing and testing of Addressable electronic loop sounder alongwith in-built isolators complete all as specified and as directed.
Supply, fix and testing of Addressable single action manual call point, resettable type, having integrally mounted addressable module to monitor and report contact status complete all as specified and as directed.
Supply and fix Fire Alarm sounders / Sirens electronic type horizontal two stage continuous normal operation for at least 50 minutes with sound level 65 db to 120 db Measured at 1.5 m with sound output variation of + 5 db 1000m range
Supply and Laying of black colored copper 2 core 1.5 sqmm Fexible electrical wire This PVC insulated and round sheathed wire features a bright annealed bare copper conductor and it supports voltage grade up to 1100 v easily,including all accessries ,all as specified and directed
Supply and Laying of 20mm steel Conduit for Surface area Including Bends, Junction Boxes,couplings, Base Saddles, Screws Etc all as specified and directed by Engr-in-Charge
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2.0 KVA
Supply, install, testing and commissioning of BEE 5 star rated hi-wall split units indoor /outdoor with cordless remote control unit and with in built filter for better indoor air quality with latest inverter technology having eco friendly refrigerent gas, copper condenser coil , capacity 1 TR all as specified and directed by the Enginer-in-Charge. Note (a)The rate consider deemed to include of bracket for fixing of indoor and outdoor unit in wall of any height as directed by Engr-in charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3 KVA complete all as specified and as directed by Engr-in-Charge.
S & F Modular Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20A rating complete all as specified and as directed.
M & L for sub main wiring with 2 runs of single core 1100 volts grade, PVC insulated, unsheathed, FRLS copper conductor cable of size 4.0 Sqmm, drawn through and including surface PVC conduit of size 20mm dia including conduit accessories including provision of 1 run of 4.0 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor complete all as specified and directed. [NOTE: 3 runs of 4.0 Sqmm cable and 1 run of PVC conduit shall be measured as one unit length.]
M&L for point wiring with 1.5 Sqmm PVC insulated and unsheathed copper cable 1100V, FRLS grade multistranded drawn in and including 20mm PVC conduit totally concealed/surface conduit in walls/ceiling with tee , bend, elbows , junction box etc. with provision of PVC insulated 1.5 sqmm copper conductor cable as earth continuity including not less than 1.0mm thick prefabricated galvanised boxes with white modular cover plate of suitable size for fixing modular switches, sockets, regulator and connected the earth wire to common earth dolly for 05 Amps Independent socket point controlled by one switch complete all as specified and as directed. Note:-(i) The quoted rate shall includes all the cost of cutting, chasing, cementing work and making all the disturbed surfaces of wall / ceiling good to match the existing wall / ceiling along with same colour.
M&L for circuit wiring with 1.5 Sqmm PVC insulated and unsheathed copper cable 1100V, FRLS grade multistranded drawn in and including 20mm PVC conduit totally concealed/surface conduit in walls/ceiling with tee , bend, elbows , junction box etc. with provision of PVC insulated 1.5 sqmm copper conductor cable as earth continuity including not less than 1.0mm thick prefabricated galvanised boxes with white modular cover plate of suitable size for fixing modular switches, sockets, regulator and connected the earth wire to common earth dolly for 05 Amps Independent socket point controlled by one switch complete all as specified and as directed. Note:-(i) The quoted rate shall includes all the cost of cutting, chasing, cementing work and making all the disturbed surfaces of wall / ceiling good to match the existing wall / ceiling along with same colour.
S& F switch modular one way 6 Amps,1 module 230V complete all as specified and directed.
S& F for modular socket outlet 3 pin, 6 Amp 2module 230V complete all as specified and directed.
S & F Pedestal Fan heavy duty having copper winding motor, AC, single phase 230/240V of size 450mm sweep, Metallic type complete all as specified and directed by the Engineer-in-Charge.
Supply & fix wall mounted fans decorative type 230 volts single phase oscillating 400 mm sweep suitable for wall mounting with 5 years on site replacement warranty complete all as specified and directed by Engg-in-Charge.
Supply & fix Air Circulator wall mounted fans heavy duty Metallic type 230 volts single phase oscillating 450 mm sweep suitable for wall mounting with 5 years on site replacement warranty complete all as specified and directed by Engg-in-Charge.
pavan putra enterprises (BID ID -3490835)
ESWAR ENTERPRISES (BID ID -3503843)
RAGHU RAMA PANDA (BID ID -3499384)
RATNA ENTERPRISES (BID ID -3503028)
Sri balaji Constructions (BID ID -3503566)
RAJASHEKHAR ENTERPRISES (BID ID -3503259)
M/S SRI VENKATA BHAVANI CONSTRUCTIONS (BID ID -3503017)
NEELESH ENTERPRISES (BID ID -3503229)
D NARAYANA REDDY CONSTRUCTIONS (BID ID -3503807)
stage.html
html • 0.07 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
Tender8518.pdf
Tender Documents • 4.15 MB
BOQ_829019.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .