Loading…
Loading…
Tender Value
₹81.1 Cr
EMD Value
₹81.1 L
Closing Date
27 Apr 2026, 5:00 pmClosed
Deputy Municipal Commissioner, North Zone
Proposed Construction of Auditorium at TP No 124C, FP No 31 (Social Infrastructure), in Thhakarnagar Ward, North Zone, Ahmedabad.
295253
E-Tender Notice 20/2025-26 Tender No.1
Open
Civil Works
Ahmedabad
4 documents required · 4 mandatory
₹18,000
Municipal Commissioner, Ahmedabad
₹81.1 L
7 Apr 2026
7 Apr 2026
7 Apr 2026
27 Apr 2026
7 Apr 2026
No Quantity Amount
Clearing and grubbing road land includding uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth upto 300mm removal of stumps of tress cut earlier and
1.01 9,215.00 disposal of unserviceable materials. Smt 2.81
A) By Mechanical means in area of light jungle.
Excavation for foundation including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.
1.02 12,460.00 (B) Dense or Hard Soil Cmt. 148.19
Upto 1.50 Mt. Depth
Excavation for foundation including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.
1.03 9,986.00 (B) Dense or Hard Soil Cmt. 160.77
From 1.50 to 3.00 Mt. Depth
Excavation for foundation including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.
1.04 12,712.00 (B) Dense or Hard Soil Cmt. 172.50
From 3.00 to 5.00 Mt. Depth
Excavation for foundation including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.
1.05 6,245.00 (B) Dense or Hard Soil Cmt. 193.41
From 5.00 to 6.00 Mt. Depth
Excavation for foundation including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.
1.06 6,245.00 (B) Dense or Hard Soil Cmt. 214.32
From 6.00 to 7.00 Mt. Depth
Excavation for foundation including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.
1.07 6,245.00 (B) Dense or Hard Soil Cmt. 235.23
From 7.00 to 8.00 Mt. Depth
Excavation for foundation including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.
1.08 6,245.00 (B) Dense or Hard Soil Cmt. 256.14
From 8.00 to 9.00 Mt. Depth
Excavation for foundation including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.
1.09 6,245.00 (B) Dense or Hard Soil Cmt. 277.05
From 9.00 to 10.00 Mt. Depth
Excavation for foundation including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.
1.10 6,245.00 (B) Dense or Hard Soil Cmt. 297.96
From 10.00 to 11.00 Mt. Depth
Excavation for foundation including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.
1.11 6,245.00 (B) Dense or Hard Soil Cmt. 318.87
From 11.00 to 12.00 Mt. Depth
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each disposited layer by
ramming and watering.
Providing and laying pre-construction Anti termite treatment as per IS-6313 (Part-II) 1971 from standard and specified agency approved by Clerk-Of-Works with ten years
guarantee in foundation, under floors and periphery as per the special agency's specifications and as per directions of Clerk-of-Work. For all levels and leads.
1.14 1,196.00 Filling in plinth with sand under floors including watering ramming, consolidating and dressing complete Cmt 455.63
Conveyance charges of lime murrum building rubbish earth, manuar of sludge and excavated rock,fly ash & surplus excavated earth from site with the any lead in the city as
1.16 31,196.00 directed by EIC etc. complete. Cmt 326.73
(A) Upto 5.00 Km
Item Total Total
Description of Work Unit Rate
No Quantity Amount
1.17 29,597.00 (B) 5.00 Km to 10.00 Km Cmt 363.78
Providing and laying rubble soling, 230 mm thick, in a compact manner,foudation, road, footpath etc. using 200 to 230 mm. cut size stones including filling the gaps with
1.18 2,347.00 40mm metal and packing with stone chips with murrum covering and levelling the surface after filling the voids including watering, ramming well and consolidating each Cmt 2,056.00
layer, as directed.
Dewatering by pumping set of Dewatering by pumping set of required capacity including temporary platform carting pumping at site and fixing the same in position
1.19 953.00 Hp/Hour 18.32
including all accessories, and fuel and labour etc. complete. Pump set of Capacity
Hiring and operating the 20 KV 3 Phase Electric Generator for operating desilting machinery, and lighting and other requirements with Arranging diesel to run the D.G. Set
1.20 275.00 Do As Directed. 8 Hrs Shift. (No payment should be allowed for non working condition of machinery) Shift 2,500.00
(AMC Drainge SOR 2015-2016, Machinary Item No.3 - 12% GST)
1.21 39.00 Hiring of Tractor with trolley considering 8 hrs. as working day hours incl. Driver (GWSSB SOR 22-23 It.No.7 pg.no.105 sec.2.E. mis) Day 2,104.09
TOTAL OF SEC:1
The structural concrete of the grade specified shall be control concrete as per IS: 456-2000. Use of weigh batcher, Mixture machine, mechanical vibrator and controlled water
cement ratio will be strictly enforced. (Use of concrete mixing plant on site will preferable and design mix shall be produced from Contractor & same approval from
st.consultants) Equivalent Quality from R.M.C. also allowed.
P.V.C spacers / Concrete spacers of appropriate size and design for the cover of reinforcement shall be used.
Item of reinforcement shall be separately measured and paid for.
In all item rates are for all floors other than specified floorwise.
Providing and laying cement concrete 1 : 2 : 4 (1 - Cement : 2 - Coarse sand : 4 - graded stone aggregates 20 mm nominal size) and curing complete excluding cost of
formwork in (A) Foundation and Plinth
Providing and laying in position Ready Mixed M300 grade concrete for reinforced cement conctere work, using cement content as per approved Design Mix manufactured in
fully automatic batching plant and transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering shuttering finishing
and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing
strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement level 475 kg) (Rate
for All Floor, All Heights, Any Shape and no extra lead given for RMC Plant) - upto plinth
Providing and laying in position Ready Mixed M 250 grade concrete for reinforced cement conctere work, using cement content as per approved Design Mix manufactured
in fully automatic batching plant and transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering shuttering finishing
and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing
strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement level 450 kg) (Rate
for All Floor, All Heights, Any Shape and no extra lead given for RMC Plant) - for all floor level with all lead and lift
Item Total Total
Description of Work Unit Rate
No Quantity Amount
Constructing cast-in situ RCC diaphragm wall by providing and laying machine batched, machine mixed, self compacting, ready mix reinforced cement concrete, tramie
controlled, of M 30 grade using minimum 400 kg cement per cum of concrete including providing and mixing required admixtures in recommended proportions as per IS :
9103, as approved by the Engineer-in-charge, for achieving 150 - 200 mm slump, for diaphragm wall having thickness as per approved structural design not exceeding
mm, in pannels of required depth and lengths as per approved drawing, including constructing necessary guide walls as required and as specified including boring in all kinds
of soils and rocks, including working in or under water and or liquid mud, in foul conditions and pumping or bailing out of water and removing slush, including disposal of
earth / rock slush etc. for all leads and all lifts, including preparing, providing and re-circulating bentonite slurry in the trench as and when required for all depths, including
agitating bentonite slurry during trenching etc., providing and fixing stop ends or form tubes, upto the required depth of diaphragm wall including extracting the same after
casting, including chipping off the bentonite adulterated concrete or unsound concrete up to the cut off level for obtaining the sound concrete, dressing undulations on the
exposed face of diaphragm wall after excavation by chipping,chiseling etc. including filling the depression/ cavities with sound concrete etc. complete and as directed by the
2.04 3,601.00 Engineer-in-charge, including providing recess for bearing plates and fixing insert boxes for inclined rock anchors etc. complete as per the specifications and approved Cmt. 13,821.00
design and as directed by the Engineer-in-charge, but including the cost of reinforcement and inserts. (rates include cost of all inputs of labour, material and T & P, cost of
handling, lifting & placing in position the reinforcement cage in the trench, including the additional cost of welding the reinforcement bars etc. involved in the work and all
other incidental expenditure for completing the work as directed by the Engineer-in-charge), However, the actual area of the diaphragm wall, correct to two places of
decimal, from design bottom level to the design cut off level (including portion anchored in the rock upto the design bottom level) only shall be measured for payment. (rates
include cost of all inputs of labour, material and T & P, cost of handling, lifting & placing in position the reinforcement cage in the trench, including the additional cost of
welding the reinforcement bars etc. involved in the work and all other incidental expenditure for completing the work as directed by the Engineer-in-charge), However, the
actual area of the diaphragm wall, correct to two places of decimal, from design bottom level to the design cut off level, including anchored as per the design, PVC tendum
with required material, including PVC water stop in each panel. Excess / less cement used for design mix including the extra cement required for under water concreting is
payable I recoverable separately.
Centering and shuttering including strutting, propping etc. and removal of form work for any height, any level, any shape any lead and lift for:
2.05 791.00 Foundations Footings Bases of Columns etc. and Mass concrete. Sqm 171.68
2.06 16,773.00 Flat surfaces such as soffits of supspened floors slabs, landings and the like. (1) Floors etc. upto 200 mm in thickness. Sqm 252.00
2.07 4,141.00 Walls (any thickness) partitions and the like including attached buttresses & string course & the like. Sqm 229.95
2.08 9,327.00 Columns, Pillars, Piers, Abutments, Posts and Struts. (1) Square Rectangular Polygonal in plan. Sqm 297.68
2.09 825.00 Columns, Pillars, Piers, Abutments, Posts and Struts. (2) Circular or curved in Plan. Sqm 422.10
2.10 37,386.00 Sides and soffits of Beams Beam Haunchings cantilevers Girders Bressumers and Lintels not exceeding 1 M. in Depth. Sqm 192.15
2.11 165.00 Sides and soffits of Beams Beam Haunchings canti-levers Girders Bressumers and Lintels exceeding 1M.in Depth. Sqm 259.88
2.12 1,386.00 Edges of slabs and Breaks in floors and walls. Sqm 67.73
2.13 489.00 Chullah Hoods, weather shades Chhajjas Corbels etc. including edges. Sqm 155.78
2.14 3,651.00 Staircase with sloping or stepped soffits including risers and stringers excluding landing. Sqm 242.55
2.15 110.00 Vertical fins and vertical sun breakers. Sqm 382.73
Extra for additional height of propping and centering where the height of propping and centering exceeds 4.0 M between supporting floor to ceiling including temporary
brick or stone pillars for supporting as required. (i) Height more than 4.0 M.and upto 5.0 M.
Extra for additional height of propping and centering where the height of propping and centering exceeds 4.0 M between supporting floor to ceiling including temporary
brick or stone pillars for supporting as required. (ii) Height more than 5.0 M.and upto 6.0 M.
Extra for additional height of propping and centering where the height of propping and centering exceeds 4.0 M between supporting floor to ceiling including temporary
brick or stone pillars for supporting as required. (iii) Height more than 6.0 M.and upto 7.0 M.
Extra for additional height of propping and centering where the height of propping and centering exceeds 4.0 M between supporting floor to ceiling including temporary
brick or stone pillars for supporting as required. (iv) Height more than 7.0 M.and upto 8.0 M.
Extra for additional height of propping and centering where the height of propping and centering exceeds 4.0 M between supporting floor to ceiling including temporary
brick or stone pillars for supporting as required. (v) Height more than 8.0 M.and upto 9.0 M.
Extra for additional height of propping and centering where the height of propping and centering exceeds 4.0 M between supporting floor to ceiling including temporary
brick or stone pillars for supporting as required. (iii) Height more than 9.0 M.and upto 10.0 M.
Steel Reinforcement (TMT Fe 500D) including supplying, cutting, bending, binding, fabricating and placing in the various items of concrete. The rate to include cost of
2.22 27,26,173.00 binding wire and concrete / P.V.C. spacers of appropriate approved design. Foundations, Raft, Footings, Pedestals, Slabs , Beams, Column, For Pardi , Wall , Stair etc. any Kg. 75.46
floor ht. as directed by E.I.C.
TOTAL SEC:2 CONCRETE AND STEEL
Item Total Total
Description of Work Unit Rate
No Quantity Amount
Brick work using common burnt clay building bricks having crushing strength not less than 35kg/Sqcm. In cement mortar 1:6 (1 cement : 6 fine sand) etc. complete as
3.01 directed by EIC.
(B) Conventional
3.01.01 898.00 Up to plinth Cmt. 3,981.21
3.01.02 880.00 Ground Floor Cmt. 4,253.46
3.01.03 469.00 First Floor Cmt. 4,293.25
3.01.04 625.00 Second Floor Cmt. 4,333.04
Half brick masonry in common burnt claybuilding bricks having crushing strength not less than 35kg/cm2 in cement mortar 1:4 (1 cement : 4 coarse sand) laid to any shape
and thickness including raking out joints, watering, etc complete. (B) Conventional
3.02.01 71.00 Basement Smt. 593.90
3.02.02 51.00 Ground Floor Smt. 646.70
3.02.03 32.00 First Floor Smt. 652.64
3.02.04 22.00 Second Floor Smt. 658.58
Brick work with common burnt clay machine moulded F.P.S. (non modular) bricks of class designation 12.5 in exposed brick work including making horizontal and vertical
grooves 10 mm wide 12 mm deep complete in cement mortar 1 :6 (1 cement: 6 coarse sand).
3.03.01 22.00 From ground level upto plinth level Cmt. 7,581.15
3.03.02 44.00 Above plinth level upto floor V level Cmt. 9,481.72
TOTAL SEC:3 BRICK WORK
Providing and laying single coat Mala plaster in C.M. 1:4 (1 cement : 4 sand) finished smooth with mala, watering etc. complete.For all levels, hights and leads of works.
Wall (Min 15 mm thickness)
4.01.01 3,409.00 Basement Smt. 155.61
4.01.02 7,662.00 Ground Floor Smt. 155.61
4.01.03 2,840.00 First Floor Smt. 178.77
4.01.04 941.00 Second Floor Smt. 201.93
Providing and laying single coat Mala plaster in C.M. 1:4 (1 cement : 4 sand) finished smooth with mala, watering etc. complete.For all levels, hights and leads of works.
Ceiling (Min 10 mm thickness)
4.02.01 10,511.00 Basement Smt 139.23
4.02.02 2,791.00 Ground Floor Smt 139.23
4.02.03 1,763.00 First Floor Smt 183.50
4.02.04 770.00 Second Floor Smt 227.77
Providing 20 mm thick double coat mala cement plaster on exterior brick / concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement
4.03 6,195.00 mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) finished with trovel including scaffolding Smt 269.78
curing etc. complete. Rate includes for all floor all lead & lift, also includes with grooves as mentioned in design.
20 mm. thick sand face cement plaster on walls upto 10 meters above ground level consisting of 12 mm. thick backing coat of C.M. 1:3 (1 cement : 3 sand) and 8 mm. thick
finishing coat of C.M. 1:1 (1 cement : 1 sand) etc. complete.
Providing 20 mm thick waterproof cement plaster using water proofing powder 1Kg/1bag of cement for all floors on brick / concrete wall work using water proofing
materials in C M 1: 4 ( 1 cement 4 coasrse sand) including finishing with a flooting coat of neat cement slurry etc complete for all floor. and shall be guaranteed for
minimum period of 10 years after handing over the completed building by the main contractor to be finished as directed. Stamp paper guarantee 10 years to be furnished
before receiving any payment from the client.
4.05.01 401.00 Inside of Basement wall, Toilet Vertical wall & RCC O.H. tank Smt 249.00
Providing and applying 2mm thick Texture Plaster of Earthen Textures, Travertino Texture, Coral texture or equivalent make incorporating fine filaments made of polymer
and aggregating natural stone powder with making grooves on existing base coat of 20 mm thick smooth mala plaster etc. Complete with two coat Exterior weather proof
paint and one coat of primer in any shade As per drawings and design supplied by architect and instruction given by authority and E.I.C. for all floor all height.
Providing 8 mm Luxture decorcem expose concerte or brick concerte coating and wall textured paint using base coat, tapping, durabond expose RCC materials and finishing
with decorsil two coat etc. complete. As per drawings and design supplied by architect and instruction given by authority and E.I.C. for all floor all height.
4.08 1,386.00 Providing cement vata (10 cm x 10 cm size) quarter round in cement mortar 1:1 including neat cement finishing, watering etc. complete. Rmt 23.45
Item Total Total
Description of Work Unit Rate
No Quantity Amount
4.09 1,386.00 Providing throating or plaster drip and moulding to R.C.C chhajja. Rmt 41.25
Wall painting (three coats) with plastic emulsion paint of approved brand and manufacture on undecotated wall surface to give an even shae incl.thoroughly brushing the
4.10 surface free from mortar dropings and other foreign matter and sand prepared smooth incl. two coat of primer Asian or equivalent brand and the cost of P/L min. two coats
of Birla putty & two coats of primer as directed by E.I.C /Consultant
4.08.01 11,442.00 Wall Smt 152.02
4.08.02 15,833.00 Ceilling Smt 159.59
Colour washing with lime on undecorated wall surfaces (Three coats) over and including priming coat of white washing to give even shade including thoroughly brooming
the surface to remove all dirt, dust, mortar drops and other foreign matter etc. complete as per E.I.C.
Finishing wall with weather proof exterior emulsion paint on wall surface (two coats) to give an required shape even shade after thoroughly brushing the surface to remove
all dirt, and remains of loose powdered materials.etc complete
as approved by Architect.
Providing and fixing Chicken wire mesh jali 16 x 24 or approved size of 22 gauge at junction of concrete and brick work / AAC Block work or between different materials
4.14 2,774.32 after making "V" grove between two different material surface and filled with rich cement mortar, nailing etc complete for all floor, any height, all shape etc complete as Smt 285.00
directed by engineer in charge.
Providing and fixing Structural Glazing with using the 17 Micron anodised of approved colour alluminium section as transium, mullium of size 63mm x 38mm x 2 mm with
using 6 mm thick reflective structural glass of approved make, colour, toughned and shade and fixed with silicone sealant and spacer tap and at corner sealed neoprene foam
dust and Air sealed gasket mirred including scaffolding, cleaning of glass etc.complete at all heights anf lifts with all necessary fitting and fixtures, anchore fasteners,
4.15 300.00 necessary M.S. or Aluminium brackets, suitable design for openable or sliding window as per Architectural drawing and as directed by Engineer-in-charge. Grooves between Smt. 4,353.00
the glasses to be filled with sealant of Dow corning - structural sealant 995, weather sealant 789. The entire facade should be water proof. The mullions are to be connected
to bracket by SS-304 nut bolts. Measurement shall be given as per actual execution of the work. (Rate are included providing & fixing of MS structure steel work when and
where requried)
ACP CLADDING -
Providing and Fixing Alluminium Composite Panel of (approved make by Architect) 4mm thick exterior grade 30 micron PVDF with coil thick of 0.25 mm & frame work
made out from Alluminium anodised section of size 50 x 25 mm (w app = 0.57 kg/m) having weight of 2.6 kg for 15' supported on Masonary/ RCC with the help of MS
Bracket fixed with Brick Fastner/ Anchor Fastner and groove filled with silicon grade 995 and 789 and G.P Where it is necessary at pressure tape Baker Rod size depend
upon gape between two Panel of bowl corning corporation make etc. complete as per Architect dwg. and as per instruction of E.I.C. (Rate are included providing & fixing of
MS structure steel work for fixing of Alluminium Composite Panel when and where requried)
Providing & fixing of GI, 84mm wide SL-4 Sun control louvers System manufactured of approved exterior grade powder coating (Visible Surface) RAL colour consisting of
84 mm wide x 0.5 mm TCT curved edged louvers having 86 mm (module) c/c and length up to 5000 mm, with square edges, Roll formed. The panel shall be powder coated
(55-65Micron) in white colour (Any RAL colour), Fire performance BS 476 part 6 (1989+A1:2009) – Class 0 & part 7 (1987) – Class 1, Impact Resistance – ASTM D2794
(5/8” ball) inch pound, front reverse, Guard Endure – D6AB, D8AB (Gloss 60-85 & 25-85), Pencil Hardness Test – ASTM D3363-05-(Derwent Graphic), Scratch
Resistance – ISO1518-1/SI83 91 17 approved. Panel shall be clipped to a steel panel carrier of 39mm wide x 86mm deep made of 0.6mm thick in standard length of
mm made of coil coated black with cut outs to hold the. The carrier will be fixed with using of G.I. L-clit of size 30 x 85mm or as per site requirement. Louvers will be fixed
on Box sturd size 25 x 42mm GI black powder coated pipe for strength of louvers etc. complete as directed by EIC.
Supply and installation exteranal cladding using Shera fibre cement plank of cassia / straight grain /teak coloured texture (exterior grade)with 8mm thickness and dimension of 150mm x
3000 mm.fibre cement board should be of minimum density1300kg/m3 (+/- 50) and comply to ASTM c 1185 and iso 8336 part (E)for confirming durability propertiesand BS 476 prt
4.18 250.00 5,6,7.thermal conductivity should be mini 0.15 w/m” k and PH value of 7-8, depending on height of structureboard to be fixed using M.S. structural steel section of suitabe with mini spacing Sqmt 3,669.00
450mm to 600 mm or as per direction of engi incharge.plank to be fixe dusing screws of tensile strength 34N and shear strength 68N on framing maintaining distance of minimum 25mm
between two planks.all plank to plank joints to be staggered and finished.
TOTAL SEC:4 PLASTER AND POINTING/ FINISHING WORK
Providing and laying Min 25 mm thick mirror polished kotah stone flooring / skirting / dedo (55 x 55 or 55 x 40cm) on min 20 mm thick cement mortar bedding 1:6, to get
fine invisible joints, Grey / colour cement floated and machien polishing etc. complete as direction by E.I.C.
Providing and laying polished kota stone slab flooring over 20 mm.(average) thick base of cement mortar 1:6 (1 cement : 6 coarse sand) or L.M. 1:1.5 laid over and jointed
with gray cement slurry including rubbing & polishing etc. complete. [A] 25 mm. thick.
Providing and laying polished kota stone slab 25mm thick in risers of steps,skirting Dedo and pillars laid on 10mm thick cement mortar 1:3 (1-Cement : 3 coarse sand) and
jointed with gray cement slury mixed with pigment to match the shade of slab including rubbing and polishing etc. complete.
Item Total Total
Description of Work Unit Rate
No Quantity Amount
Providing and laying rough kota stone slab flooring over 20 mm.(average) thick base of cement mortar 1:6 (1 cement : 6 coarse sand) or L.M. 1:1.5 laid over and jointed
with gray cement slurry including rubbing & polishing etc. complete. [A] 25 mm. thick.
Providing and laying Paver Cobel Granite Stones (100 mm x 100 mm x 50mm) over 1 : 3 cement mortar (1 cement : 3 graded medium coarse sand) bedding of average 1”
thickness, floated with thick and neat cement paste with consumption of cement @ 4.4kg / sqm and 2 kg / sqm for joints mixed with approved pigment to match the shade of
the stone including dressing, rubbing, curing, cleaning etc. complete at all levels and heights. (The rate shall be for the patterns and details provided by the Architect. If
required, residues will be provided and no extra amount will be paid for residues to be used to achieve the pattern).
Providing and laying machine cut, mirror polished, Italian Marble stone flooring laid in required pattern in linear portion of the building all complete as per architectural
drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @
5.06 360.00 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified Smt 6,785.00
and as directed by the Engineer-in-Charge.
a. 18 mm thick Italian Marble stone slab as approved by Architect or EIC.
Providing and fixing machine cut, mirror/eggshell polished, Marble stone work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design
and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3coarse sand) laid and jointed with white
5.07 9.00 cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as Smt 9,022.00
per Architectural drawings, and as directed by the Engineer-in-Charge.
a. 18 mm thick Italian Marble stone slab as approved by Architect or EIC.
Providing and laying Full body glazed/double charge/matt finished vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption
less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including
grouting the joints with white cement and matching pigments etc., complete. Colour and shade as approved by architect. All joints filled with epoxy grout (avg. 4*10 to12
mm).Rate includes for all lead & lift & as per directed by EIC.
5.08.01 455.00 600 x 600 mm Smt 1,926.00
5.08.02 2,353.00 800 x 800 mm Smt 2,271.00
Providing and laying Full body glazed/double charge/matt finished Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less
than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps,dedo over 12 mm thick bed of cement mortar 1:3 (1 cement:
coarse sand), including grouting the joint with white cement & matching pigments etc. complete. Colour and shade as approved by architect. All joints filled with epoxy
grout (avg. 4*10 to12 mm).Rate includes for all lead & lift & as per directed by EIC.
5.09.01 908.00 600 x 600 mm Smt 1,950.00
5.09.02 117.00 800 x 800 mm Smt 2,300.00
Providing & fixing mirror polish Granite for Door Jamb, Sill and the like similar location of 18mm thick, from 1050 to 2105mm in length and width 150mm /250mm in
cement mortar 1:2 [1 white cement : 2 marble dust] with an admixture of pigment to match the marble shade including fixing with copper pin 7.5cm long of 6mm diameters
in cement mortar 1:2 (1 cement : 2 fine sand) including making rebate for door shutter in Granite, edge polishing and moulding etc. completed as directed by EIC /
Consultant.(Clear measurement will be taken on sqmt basis for both Jamb)
Providing and laying lift cladding min.10 mm th. machine cut and mirror polished granite stone for column / wall cladding by using araldite, stainless steel pins it required
including scrapping the surface and making the surface preparation for cladding. Also include for finishing the joints and exposed edges shall be polished and finished with
white cement slurry admixed with the approved shade pigment to match the shade of tiles as per inst. of Architect etc., complete including champhered edges & V grooves
complete as per design. Including cost of 20 mm thick backing coat in C. M. 1 :
Providing and fixing 18mm thick machine cut River wash finish Granite flooring / skirting / dedo of approved quality by architect over 20 mm (average) base of cement
5.12 55.00 mortar 1:4 (1 cement : 4 coarse sand) for staircase steps, entrance,dedo, platform,shelves, flooring, lift etc. with machine cut edges as required and laid in desired pattern. Smt 3,985.00
The rate are included to provide groove in flooring and edge moulding wherever requried etc. comp.
Providing and laying 18 mm thick Granite stone in single piece (min. size 1500 mm) for staircase flooring landing, risers & treads, skirting over 10 mm. average thick base
5.13 1,215.00 of cement mortar 1:3 (1 cement : 3 coarse sand) and laid over and jointed with grey cement slurry including rubbing and polishing etc. complete. including making edge Smt 2,152.00
rounded including making rough finish at edge & groove etc. complete.
Providing and fixing Granite sand which type platform, counter wash basin including supplying and fixing granite stone 18 mm thick mirror polished 1st quality Granite
stones in top and side posiition and vertical strip at front over 25 mm thick polished kotah stone platform fixing in top and sides and itermediates supports fixing with
cement mortar and adhesivee and finishing including providing & cutting of kitchen sink (as directed) 600 mm x 450 mm x 200 mm size stainless steel sink (as directed by
engineer incharge) at required position etc complete.
Item Total Total
Description of Work Unit Rate
No Quantity Amount
Providing and laying white / coloured ceramic tiles of 1st quality of specified size, colour, shade and of approved make, in floor with cement paste on and including
5.15 1,802.00 bedding.coat of plaster in cement mortar (1:3). All joints filled with coloured / white cement putty as per architect detail and wiped to give sharp joints with flush pointing Smt 960.47
and washed clean with acid as direction by E.I.C.
Providing and laying coloured glazed tiles in skirting, risers of steps and dedo on 10 mm. thick cement plaster 1:3 (1 cement : 3 coarse sand) & jointed with white cement
Providing and laying Min 25 mm thick River Wash Kotah stone flooring (55 x 55 or 55 x 40 cm) or platform slab size for stair, pantry (not less than 1500mm long size) with
5.17 55.00 hand dressed and filled edges, set complete on min 20mm thick cement mortar bedding 1:4, with machine cut edges as required and laid in desired pattern. The rate are Smt 1,941.00
included to provide groove in flooring and edge moulding werever requried etc. comp. as direction by E.I.C.
TIC - TAC Tile
5.18 236.00 Providing & laying Tac tile 300mm x 300mm x 15mm flooring. The tile laid using with adhesive as per site condition including all labour and material, cleaning, curing, Smt 7,178.00
etc., complete all As per drawings and design supplied by architect and instruction given by authority and E.I.C.
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of :
(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off
junction of vertical and horizontal surface.
(ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of
vertical and horizontal surface.
(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.
(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wid and pasted to each other with bitumen @ 1.7 kg/sqm). Rate
includes for all lead & lift & as per directed by EIC.
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of
following operations:
(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge
over the RCC slab includingadjoining walls upto 300 mm height including cleaning the surface before treatment.
(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1 : 5 (1 cement : 5 coarse sand) admixed with water
proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand) admixed
with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height
including rounding of junctions of walls and slabs.
(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS :
and approved by Engineer-in-charge.
(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS :
and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement
slurry and making pattern of 300 x 300 mm square 3 mm deep.
(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and
as directed and specified by the Engineer-in-Charge :
With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Providing & laying china mosaic flooring on top of integral waterproofing using small broken chips of white/colour glazed tiles set in crazy pattern, as desired by Architect,
in cement mortar laid to required slopes and simultaneously filling in remaining top joints in the waterproofing layer and tamped with wooden block to get smooth even
5.21 1,858.00 surface to required slope, filling the joints with cement grout, cleaning the surface on completion and curing etc. complete. The work sahll be carried out in a workman like Smt 739.89
manner to make the give a guarantee on stamp paper for the performance for a period of ten years. The work shall be measured in square meter of the actual area laid and no
extra shall be paid for vatahs, rounding at junction of wall and floor and around water spouts, water outlets etc.
50 mm thick I.P.S. in cement concrete 1 : 2 : 4 laid in levels and grades desired in bays as directed and finished smooth by mala floating including curing, marking of bays
with thread as directed etc. complete.
Item Total Total
Description of Work Unit Rate
No Quantity Amount
CC PAVEMENT
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement concrete work, using cement content as per approved Design Mix manufactured
in fully automatic batching plant and transported to site of work in transit mixer for a lead up to 10 Kms. having continuous agitated mixer, manufactured as per mix design
of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying in levels and pattern of bays as detail of architect
and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc., finishing and reinforcement including
cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per
direction of the Engineer in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained). The rate shall include cost of side shuttering with
channels, rails, to form panels and groove cutting etc. including filling the joint with glass strip/polysulphite complete to use. The rate shall also include the cost of
reinforcement approximate calculated at 5.14 kg/Smt. Rate for all lead & lift & as per directed by Engineer in - charge.
(Note: - Cement content considered in this item is @450 kg/cum.)
TOTAL SEC:5 FLOORING AND PAVING
Providing and fixing flush door both sides laminated and I.T.W. beading all around by using I.T.W. frame 120 mm x 80mm shutter fabricated from 35 mm thick solid core
malemine faced three layered pre laminated flat pressed wood based exterior grade bonded BWP / BWR synthetic resin having stamped IS 12823 grade I type II including
three coats of lacquer polishing to exposed wooden surfaces and Stainless steel decorative type designs fixtures / fastening 2 Nos. Handles, 2 Nos. Aldropes, towerbolt
etc.including I.T.W. triangular batten patti of size 30mm x 30mm etc. as per architectural detailed drawing and as directed by engineer in charge.
6.02 79.00 Providing and fixing OZ-BHF-2BB 4 x 3 x 3 mm SS Ball Bearing Butt Hinges for Flush Door OZONE make. Nos. 382.83
Providing, Fabricating and Erecting in position anodised (15 to 25 micron of desired colour) door shutter (double action opening) of standard aluminum section from 18mm
(3/4”) series of Jindal, Hindalgo, Domal or approved equivalent make of size as described below or of higher series if required as per site condition-top and vertical style
6.03 32.00 47.62 x 44.45 x 2 mm (w approx = 1.05 kg./m), lock rail and bottom section 114.30 x 44.45 x 2 mm (w approx = 1.83 kg/m), fitted on frame of size 101.60 x 44.45 x 2 mm Smt. 4,574.00
(w app = 1.60 kg./m) with standard accesories like handle , stopper, locking arrangement, C.P. brass hinges, etc, and glazing of 5 mm thick float glass of Mody or approved
equivalent, fixed with rubber / PVC beading in upper and lower panel complete with 12 mm both side pre laminated sheet as per architecture detail dwg.
Providing and fixing window having extruded aluminum Colour anodized section frame main outer size 63.50 x 38.10 x 1.95 mm(of Jindal Section no:4605,@ Wt 1.094 Kg
/ Rmt), horizontal two track member size 61.85 mm x 31.75 mm x 1.20mm (of Jindal Section no: 8687 @ wt.of 0.695 Kg/mt), vertical member of size 61.85 mm x
31.75mm x 1.30 mm (of Jindal Section no:8758 @ wt.of 0.0.659 Kg/mt) with sliding shutters of horizontal member size 40mm x 18mm x 1.29mm (of Jindal Section
no:8949 @ wt.of 0.456Kg/mt), vertical member of size 40mm x 18mm x 1.29mm (of Jindal Section no: 8947 @ wt. of 0.456Kg/mt, Section 8948 @ Wt. 0.457 Kg/mt) with
5 mm thick transparent bronze colour tinted float glass with powder coated aluminum fittings and fixtures and transparent silicon sealant glass fixing to frame as per details
etc complete for window.
Providing and fixing window having extruded aluminum Colour anodized section frame main outer size 95mm x 24mm x 1.17mm (of Jindal Section no:2459 @ wt.of
Kg/mt), horizontal Three track member size 92mm x 31.75mm x 1.30mm (of Jindal Section no:8688,@ Wt.1.07 Kg/mt), vertical member of size 92mm x 31.75mm x
6.05 85.00 1.50mm (of Jindal Section no:8933,@ Wt. 1.06 Kg/mt) with sliding shutters of horizontal member size 40 mmx18mm x1.29mm (of Jindal Section no:8947@ wt.of 0.456 Smt 1,568.27
Kg/mt), vertical member of size 40mm x 18mm x 1.29 mm (of Jindal Section no:8949 @ wt.of 0.456Kg/mt/ with 5 mm thick transparent bronze colour tinted float glass
with powder coated aluminum fittings and fixtures and transparent silicon sealant glass fixing to frame as per details etc
Providing and fixing standared extruded of alluminium section of size 63mm x 38.10mm x 1.2mm (Jindal Section :2434, @ Wt. 0.643 Kg/mt) with colour anodized
alluminium frame for ventilation with 5 mm thick frosted glass as details etc complete for Ventilation
Providing and Fixing FRP FRAME size 125 x 65 mm and 35 mm thick FRP shutter with wood grain raised pannel design finish shutter having extra reinforcement on sides
and edges and in polish finish The core of the shutter is to be filled up with injected fire extingushing grade.polyurethane foam done in situ along with embedded wooden
6.07 147.00 pieces for stiffering and also for tacking hinges and fixtures. The whole FRP frame and shutter is to be water proof.weather proof,tennite proof and resistance to mild acid/ Smt. 1,999.98
Alkali, Rates are to be inclusive of S.S. hinges with necessary screws and brass fixtures and fasening. Product should have 3 years performance guarntee and company have
ISo 9001-2000 certificate.
Item Total Total
Description of Work Unit Rate
No Quantity Amount
Providing and fixing stainless steel (Grade 304) for railing, Expansion joint covering etc. made of Hollow tubes, channels, plates, pipes etc., including welding, grinding,
buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary
6.08 4,510.00 accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per Kg. 633.00
approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners
Providing and fixing stainless steel (Grade 304) railing made from 50 mm OD pipe with 1.5 mm thick on top, Boluster of 38 mm dia OD pipe with 1.5 mm thick and
mm thick frosted toughened glass including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless
6.09 374.00 Meter 6,981.00
steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor
or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge
Providing & fixing rolling shutters of approved make made of 80 mm. Wide M.S. laths inter locked together theit entire length and jointed together at the end locks mounted
6.10 37.00 on specially designed pipe shaft with bracket plates, guide channels and out side locking with push-pull operation excluding the cost of Hood cover and spring etc. comp. (A) Smt 2,718.41
Shutters having width below 3.5 mt.
6.11 11.00 Providing and fixing hood cover for rolling shutters. (A) Shutters having width below 3.5 meters. Rmt 120.03
6.12 5.00 Providing and fixing 27.5 cm long wire spring grade No 2 of approved make for rolling shutters. No. 630.91
Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider
Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider
& bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel
brackets & Anchor bolts and at the bottom using SS channel of 50 x 25 x 2 mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/
nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to
accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be
filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing
including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts,
washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of
joints and the portion of Glass panel inside the SS channel shall be measured.
Dormakaba ES PROLINE Automatic Sliding Door Operator
Dormakaba automatic Sliding door operator ES 250 PRO Easy 6150 mm with low-noise drive motor without gearbox, TÜV design tested for 1.5 Million Cycle of opeartion
in accordance with low voltage guidelines of IEC /EN 60335-2-103 and fulfils EN 16005 and DIN 18650-1 / DIN 18650-2 standards. With the clear passage width up to
3000 mm. The Profile Finish should be Silver Anodized E6/C0, with operator dimensions (H x D) : 100 x 180 mm. Drive with acoustically decoupled and exchangeable
running rail and wear-resistant special surface. Rollers made of special plastic, Counter rollers as derailment protection.Mounting plate with prefabricated fixing holes and
threaded holes. Microprocessor-controlled control unit, Self-learning, with adjustable parameters for opening and closing speed, hold-open time 0- 180 Sec, with smps,
Class of protection IP 20.Program Switch with Knob, ES 250 PRO Easy, Maximum Panel Weight Carrying Capacity of 2X 125 Kgs & 1X 125 kgs each leaf. The Max.
opening and closing force by the opeartor should not exceed 150N and maximum power consumption should not exceed 130W during opeartion mode.The operator should
be equipped with EM failsafe / fail secure lock with Nemo Combi sensor with 2x Microwave for activation and double rows of 24 spots failsafe Safety infrared curtains
without the need of Photocell. The system shall have constant power supply 230V+ 5%, 50Hz, AC .
TOTAL SEC:6 DOOR-WINDOW/ STEEL WORK/ S.S. WORK
Providing and Fixing of Hi-Rib Roofing System comprising of Hi-Rib profiled sheeting 1000-1015 mm. cover width of 30mm. crests @ 250-255mm. c/c. manufactured out
of 0.5 mm TCT (Total Coated Thickness) SMP coated galvalume (550 Mpa yield stress) steel. The sheet shall have wide pans with stiffening ribs for effective water
shedding and special male/ female ends on side-laps for purlin support and anti-capillary flute in side-lap. (The sheet shall have hot-dip metallic coating of zinc aluminium
7.01 1,760.00 alloy coating mass total of both sides, AZ -150 as per AS-1397. The sheet shall be 20 micorn top coat applied over 5 micron primer and conversion coat and a 5 micron Smt 955.00
polyester back coat along with the self-drilling fasteners. The sheet shall be supplied in custom lengths and for maximum upto 12mtr. The maximum end lap of sheet shall be
150mm and sealed with silicon sealant.) The sheet fixed with GI rubber coated J or L hook, bolts and nuts 8mm dia. with polyemer protective caps and antileackage washers.
Only covered area shall be measured for the payment.
Item Total Total
Description of Work Unit Rate
No Quantity Amount
Providing and Fixing of ridge manfuctured out of same material as mentioned above in Item No : 1 on roof sheet and purlin fixed with GI Rubber coated J bolt and protective
7.02 66.00 polymenr caps and antileackage washers and GI round washers minimumn 2 nos. per sheet on the purlin with matching profile between the ridge and roof sheeting panels Rmt 955.00
etc. complete as per the details.
Providing and Fixing Flashing, Capping and Gutters manufactured out of same material as mentioned Item No : 1 in standard length of 2.5 Mtr. and fixed by means ofhex-
head self-drilling stitching screws.
Providing and fixing Under Deck Insulation work by using knauf make glass wool of 50mm thick, 48 kg/m3 density with aluminum foil. Including all accessories, material
& labor complete as directed by Architect / Engineer – in – charge
Providing, supplying, fabricating and erecting in position the structural steel for colums, grill, gates, bars, truss, purlins, runners, cleats, insert plate, base plate etc for all
structural elements as per detail, made up from closed structural steel hollow sections (RHS/SHS including rolled section ) or angle or chanel with weather resistant of Tata
7.05 13,679.00 Structural / sections or an approved equivalent as per details / drawings/instructions including cutting, bending, jointing, connecting, welding and / bolting and / riveting and Kg. 109.00
fabricating and erecting in position etc complete for all levels as directed. The rate to include all necessary fixtures, fastening including welding rods of standard approvded
quality etc for complete the job. The rate shall also include the two coats of synthetic enamel paint with priming coat & necessary scaffolding etc. complete as directed
Providing, Fabricating and erecting TATA Structura or equivalent Pre Fabricated or Pre-engineering Structure made of sections made from high tensile steel plate having
7.06 11,000.00 strength of E355 grade (YST 355 Mpa & UTS 490 Mpa) including necessary connections, welding, insert plastes, slidce plate etc. complete with one coat of zinc chrome and Kg. 156.00
two coat of enamel paint etc. complete as directed by EIC.Rate includes for all floor all lead & lift.
Providing, Fabricating and erecting TATA Structura or equivalent Pre Fabricated or Pre-engineering Structure made of sections made from high tensile steel plate having
7.07 4,950.00 strength of E310 grade (YST 310 Mpa & UTS 450 Mpa) including necessary connections, welding, insert plastes, slidce plate etc. complete with one coat of zinc chrome and Kg. 104.00
two coat of enamel paint etc. complete as directed by EIC.Rate includes for all floor all lead & lift.
TOTAL SEC:7 ROOFING
Providing and fixing pre-cast Rubber moulded inter locking concrete block 80mm thick with grade of concrete M40 pnumatic compressed by mechanically pressed and as
8.01 1,498.00 per approved design including 75mm sand layer for levelling and filling the joint with sand in proper line and level etc. complete and including cost of carting of debrises in Smt. 1,173.00
out side of premises with all lead & lift as directed by engineer in charge.
Providing and fixing pre-cast concrete kerb stone of gray cement based concrete block 30cm length, 30cm height and 15cm thick of M250 grade concret as per approved
design and including excavation for fixing in proper line and level, filling the joint with C:M 1:3 (1cement:3fine sand) etc complete.
8.03 50.00 Providing & Fixing AUTOGLOW Signages in Block / Small Letters of Specified Sizes Fire lift size: 4" X 12" Each 298.93
Sunk filling
8.04 187.00 Providing and laying Autoclave Aerated Concrete Block chips/bats (for shallow sunk) cement concrete in 1:4:8 (1 Cement : 4 Coarse Sand : 8 graded Autoclave Aerated Cmt 4,272.00
Concrete Block chips/bats) grade including compacting, finishing, curing, form work (if required) etc. complete as directed by engineer in charge.
Providing & fixing of reinforcement bars after drilling the hole of required diameter & depth, cleanning of the same, providing / filling the hole with Injection Mortar (HIT
HY 200r of Hilti or approved equivalant),inserting reinforcement bar etc. complete as per Manufacturers & architects instruction. The work shall be carried out by the
technical workmens/agency approved by the manufacturer and under technical supervision of Manufacturer of Injection grout including all materials, tool tackles, labour etc
completed as directed by E.T.C / PMC. Rate shall be included required testing like pull-out etc. & over all design shall be measured forces by structural design consultant.
8.05.01 110.00 for 20 mm. dia.bar -Holes 25mm dia Depth 200mm to 250mm Each 1,087.00
8.05.02 110.00 for 16 mm. dia.bar -Holes 20mm dia Depth 160mm to 250mm Each 604.00
8.05.03 110.00 for 12 mm. dia.bar -Holes 14mm dia Depth 120mm to 200mm Each 253.00
8.05.04 121.00 for 10 mm. dia.bar -Holes 12mm dia Depth 100mm to 175mm Each 207.00
8.05.05 132.00 for 8 mm. dia.bar -Holes 12mm dia Depth 100mm to 175mm Each 184.00
Making holes upto 50 mm dia. 300 mm long in any RCC members by diamond Core Cutting machine of HILTI or equivalent including disposing the debries etc completed
as directed by E.T.C/PMC .
Making holes upto 100 mm dia. 300 mm long in any RCC members by diamond Core Cutting machine of HILTI or equivalent including disposing the debries etc
completed as directed by E.T.C/PMC ..
Item Total Total
Description of Work Unit Rate
No Quantity Amount
Making holes upto 150 mm dia. 300 mm long in any RCC members by diamond Core Cutting machine of HILTI or equivalent including disposing the debries etc
completed as directed by E.T.C/PMC .
Providing & Fixing anchor fasteners of Fischer make or approved equiv. including drilling in RCC / Masonary Members, fastening with structural steel members etc
8.09 66.00 complete. No. 362.00
a) 8 mm dia. 110 mm long
Providing & Fixing anchor fasteners of Fischer make or approved equiv. including drilling in RCC / Masonary Members, fastening with structural steel members etc
8.10 66.00 complete. No. 431.00
a)10mm dia. 110 mm long
Providing & Fixing anchor fasteners of Fischer make or approved equiv. including drilling in RCC / Masonary Members, fastening with structural steel members etc
8.11 66.00 complete. No. 610.00
a)12mm dia. 110 mm long
Providing and Fixing ABS Plastic SPEED BUMP of Size :- 750 mm x 250 mm x 75 mm, Per Mtr # 4 Nos (2 black, 2 yellow), TOP DESIGN – LINE DESIGN ANTI SKID
PATTERN FOR GRIP fililing CEMENT INSIDE etc. complete as directed by Engineer-in-charge.
Providing and fixing 1mm thick steel deck sheet of TATA Smartdek or approved make having steel confirmed to AS1397, YST345MPA and BS EB 10147 : 2000 120 gsm
8.13 220.00 including hot dipped zinc coated high strength steel having coating of Z180 (min 180 g/sqmt total of zinc coated on both sides) fixing with self driven screw of size 12 x 24 x Smt 1,518.00
38 mm (max. drilling - 8mm) etc. complete as directed by EIC. (Rates are included Shear Connectors)
Cubical Toilet
Supply and install modular toilet cubicles of MERINO-BESCO make 'ZMS SS' series as per manufaturer's std specifications.All intermediate panels, pilasters, doors shall be
made up of Solid Compact Laminate of 12 mm thickness (Phenolic Core Board) as per IS 2046 based on thermosetting resins, homogeneously reinforced with cellulose
fibers making cubicles impervious to Water, resistant to Fire, etc. Compact laminate should be Greenguard and IGBC certified
Thickness of Compact Laminate : 12mm
Color of HPL Boards: Single Standard Compact Color
Special Remarks For Customization:
Size of Cubicle : 1000mm (W) X 1550mm (D) X 1980mm (H)
Door Size : 1750mm (H) X 600mm (W)
Divider Size : 1775mm (H)
Overall Height Of Cubicle : 1980mm (Including bottom Gap of 150mm)
Accessories:
8.14 66.00 Standard - Merino Make Stainless Steel - 304 Grade accessories) No. 36,317.00
a) SS "U" Channel
b) SS "F" Channel (Only Corner Unit)
c) SS Door Stopper Channel
d) SS Top Rail
e) SS Coat Hook
f) SS Privacy Thumb turn c/w Occupancy Indicator
g) SS Door Knob
h) SS Spring Loaded Butt Hinges with Cover
i) SS Adjustable Foot - 316 Grade
j) Rubber Lining for Door Stopper
k) Screws & Wall Plugs
SPECIAL NOTE - Warpage Criteria is 3.0 mm/1000mm for MRS panels as per EN standard-
Providing and fixing of Urinal Modesty Panels (UMP) for Urinals of Length - 1200mm, Width - 450mm and Panel thickness - 12mm, design of panel as per architect.
(Make:- Merino or Equivalent)
Item Total Total
Description of Work Unit Rate
No Quantity Amount
Providing and fixing 100 mm expansion joint system of Horizontal Internal : Floor to Floor FF : The work shall consist supply and installation of joints and seals -expansion
/ seismic joint system model MSDSZJ / SFFS / MSD -QZJ -SFFS / MSDGCP in accordance with the drawings and requireements of the specifications below. The joints are
proprietary design utilizing extruded aluminum base members, self aligning / centering arrangement and support plates.The material shall be such that it provides wateright
flat joint cover expansion control sysytem that is capable of accommodating multidirectional seismic movement without stress to its components.System shall consisit of
metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and floor / roof treatments. The cover plate shall be
designed of width and thickness requried to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer's pre-engineered self-
centering arrangement that freely rotates / moves in all directions. The self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the
corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement, Including EPDM Profile including cost
of GP2 grouting. The joint sysytem shall resist damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants as per manufacturer speciation
and the joint design and drawing, complete.
Providing and fixing 100 mm expansion joint system of EM / MSNG / MSNSK system designed for internal / External wall and ceiling finishes with expansion movement
of design for internal / EXTERNAL application on wall to wall / ceiling / wall to corner where exposed metal plate / consealed metal plate / flush metal plate desired as per
the joint design and design width over the joint profile INCLUDING EPDM Profile including GP2 grouting as per the joint manufacturer speciation and the joint design and
drawing complete. (Vertical)
Providing and Fixing Trap Door
(A) Size 1300 x 700 mm
8.19 22.00 (B) Size 2300 x 1250 mm Nos. 25,766.72
8.20 22.00 (C) Size 1600 x 800 mm Nos. 11,923.96
8.21 165.00 Providing and Fixing catpitch cover of LD-5 tonne capacity Nos. 1,696.25
MCM Cladding
Providing and fixing clay material and stone poweder cladding with 5 mm to 10 mm thick clay sheet of size 600 x 1200 with any shape cladding with using requre PU,
Cement, Polymer based adhesives with all accessories, material & labor complete as directed by Architect / Engineer – in – charge. Providing and fixxing of M.C.M.
Cladding as approved by Architect.
HIGH PRESSURE LEMINATE BOARD
Providing and fixing HPL board as per drawing, HPL as per is 2046 & en-438 manufactured under high pressure >5 mpa & temperature >120 cc with bunch of craft paper
impregnated with thermo setting phenolic resin & decorative paper mades of alpha cellulose fiber impregnated with thermo setting malamine resin which provide superior
scratch,abrasing heat,chemical,impact,graffiti & moisture resistance along with anti bacterial properties. With hardware & accessories from besco , all screws,hinges, coat
hook,privarcy indicator,top rail in 304 stainless steel with wall and corner joinery and adjustable legs in 316 ss grade. And anti noise rubber pads including all material,
labour and hardware, waste of materials and complete the work satisfactorily as per instruction of architect or Engineer-in charge.
8.24 110.00 Sinage - internal and external signage boards in vinyl etc. as per architects details Sq.mt. 5,600.00
8.25 110.00 Sinage - internal and external signage boards in aluminum, ACP sheet, S.S., wood etc. as per architects details Sq. inch. 42.00
Toilet Ceiling
Providing and fixing tiled false ceiling of size (600x600) mm in true horizontal level suspended on inter locking Gyproc Matrix metal grid of hot dipped galvanized steel
sections. It consists of main "T" runner of size 24 x 32 x 0.3 x 3600mm, cross "T" of size 24x25x0.3x1200mm, secondary cross "T" of size 24 x 25 x 0.3 x 600mm and PPGI
wall angle of size 24x24x0.4x3000mm. Bottom exposed capping of width 24 mm of all Tsections shall be of 0.25mm thick PPGI. PPGI wall angle 24 x 24 x 0.4 x 3000mm
{MaterialGI(IS513),YS-280Mpa,Finish-Galvanised 90GSM(IS277)} is fixed along the perimeter of the ceiling to Walls, partitions or columns etc., with wooden screws at
300mm centers or Hilti HPS 6 x 40mm placed at 600 mm c/c. Gyproc soffit cleat 27 x 37 x 25 x 1.6mm {GI(IS513)YS-260Mpa,Finish-Galvanised 120GSM(IS277)} is fixed
with Gyproc Rawl Plug- 8 x 45mm {Material-IS 513 CR2 grade, Zinc coating (7 to 8 microns) pull out load- 6.8kN for M30 concrete grade} creating 1200mm x 1200mm
grid. Main-T runners 24 x 32 x 0.3 x 3600mm {GI(IS513)YS-280Mpa,Finish- alvanised 120GSM(IS277) are then suspended at 1200mm c/c. from ceiling using 4mm zinc
electroplated butterfly level clips of size 85 x 30 x 0.8mm spaced at maximum 1200mm center to center along main T and not more than 150mm from spliced joints. The last
hanger at the end of each main runner should not be greater than 600mm from the adjacent wall. 24 x 25 x 0.3 x 1200mm cross T {GI(IS513)YS-280Mpa,Finish- Galvanised
120GSM (IS277)} is interlocked between the main T at 600mm center to center to form a grid of 1200x600 mm and then secondary cross “T" 24 x 25 x 0.3 x 600mm {GI
(IS513)YS- 280Mpa,Finish-Galvanised 120GSM(IS277)} is then interlocked at middle of the 1200x600mm grid to form grids of 600x600mm. Cross Tees at the ends
having length more than 600mm are to be supported independently. Finally 9.5/12.5mm thick square edge Gyproc Polyshield Gypsum tile (meets requirement of
specification mentioned under DAR no. 12.52.3 in Delhi Schedule of rates (DSR)), of size 595 x 595mm, made of Gypsum plasterboard, manufactured from natural gypsum
as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges
sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges, so as to make the tile a completely sealed unit, is placed in the grid.
Item Total Total
Description of Work Unit Rate
No Quantity Amount
S.S. Mural
8.27 193.00 Providing and Marking MURAL made out of 2mm thick s.s. plate grade 304, including making necessary design as per Architect dwg. Through laser cutting including connection to the Sqmt 19,780.00
R.C.C./Masonary with necessary frame,anchor fastnuts,M.S.Plate etc. complete at any floor any height.
METAL CEILING
Providing & Fixing of Lay-in perforated tile false ceiling on 24mm ‘T’ Framework of module 600mm x 600mm. Panels shall be manufactured of size 575mm x 575mm
made out of 0.5mm TCT thick GI. The perforation shall be 1.8mm (20% open area) & 2.5mm holes (16% open area) in a 3mm diagonal pattern. The Tile shall be powder
coated (60Micron) in white colour, Fire performance BS 476 part 6 (1989+A1:2009) – Class 0 & part 7 (1987) – Class 1, Impact Resistance – ASTM D2794 (5/8” ball) inch
pound, front reverse, Guard Endure – D6AB, D8AB (Gloss 60-85 & 25-85), Pencil Hardness Test – ASTM D3363-05-(Derwent Graphic), Scratch Resistance – ISO1518-
1/SI83 91 17 approved in module size of 600 x 600mm. The Tile will be manufactured on advanced equipment, which includes several levelling. The tile shall be
manufactured in a single stage manufacturing procedure from a die. Grid system for fixing ceiling tiles shall comprise of Tees. The 24mm main tee runners shall be
suspended at an interval of 1200mm c/c. The 24mm cross tee runner shall be suspended at 600mm c/c and further supported with 24mm cross tee at 600mm c/c with
interlocking arrangements to form grid of 600mm x 600mm. The main tee shall be supported by means of 4mm GI rod from slab/roof. The suspension shall be provided at
1200 to 1500mm c/c. etc. complete as directed by EIC.
8.29 275.00 Providing and fixing of brass T Patti with black or dark gray finished or approved by architect on the wall, including all accessories labour charges complete. Rmt 403.00
Providing and fixing Wood plastic composites (WPC) fluted wall cladding of required size including approved shade in approved pattern as directed by the architect. Rates
shall be inclusive of all hardware fittings and fixtures as required to fix the same on the wall and ceilings including corner beading and fastners.
Designing, Providing and erection of ferro cement work "Elevation design" with ferro cement sturcutre 40mm-100mm thickness of structure as per the design with a cement
8.31 110.00 mortar of 1:4 (1 cement : 4 sand), 6/8/10/16, 25 mm FE500 TMT bar, chicken mesh 14x14 , weld mesh jali as per requirement, GI wire, additives, welding, painting with Sqm 6,095.00
required colour and pigments and all necessary labour, tools, equipments and scaffolding etc as directed engineer and charge and as per the design provide by architect.
TOTAL SEC:8 MISCELLANEOUS ITEM
TOTAL AMOUNT
TOTAL AMOUNT
AHMEDABAD MUNICIPAL CORPORATION
Construction of Auditorium At TP No 124C, FP No 31 (Social Infrastructure), in Thhakarnagar Ward,
North Zone, Ahmedabad.
Summary Sheet Of Plumbing Work
Sr. No. Item Description Amount
1.0 Sanitary Fixtures & CP Fittings
2.0 Internal & External Drainage
3.0 Internal Water Supply
4.0 External Drainage Line Network
5.0 Plants & Equipments
GRAND TOTAL
GRAND TOTAL
AHMEDABAD MUNICIPAL CORPORATION
Construction of Auditorium At TP No 124C, FP No 31 (Social Infrastructure), in Thhakarnagar Ward, North Zone, Ahmedabad.
BOQ for Internal Plumbing Work
Sr.No. Item Description Unit Quantity Rate Amount
1 Sanitary Fixtures & CP Fittings
Providing & Fixing Water Closet (European Type W.C. pan ) Wall-Hung Water Closet with
Quiet Close Seat and Cover in White with P-trap including seat cover and Conceal Flush tank &
Complete with all other accessories having dimension as per manufacturers of approved make and
conforming to Manufacturers Standards as per Drawing, Technical specification & instructed by
Consultants in charge.
Code no. SKU: K-26998IN-0 Kohler Make, Conceal Tank 20084IN-M-NP
Providing & Fixing Water Closet (European Type W.C. pan ) Wall mounted, with Chair
1.2 Bracket / Anchor Fasteners, Open or Concealed Flushing Tank, Complete One Unit Testing & Nos. 1.00 15,150.00
installation as per drawing & specification. For Common Area ( Make Jaquer)
Fixing Wash Basin Table Top , with necessary CI or MS brackets, Bottole trap fittings, 40 mm
1.3 dia CP waste coupling, Testing & installation as per drawing & specification. Nos. 43.00 17,675.00
Code no,: Kohler K-5373IN-0
Providing & Fixing Wash Basin Wall mount type , with necessary CI or MS brackets, Bottole
1.4 trap fittings, 40 mm dia CP waste coupling, Testing & installation as per drawing & specification. Nos. 1.00 6,565.00
For Common Area ( Make Jaquer)
Providing & Fixing Urinal sensor type opearting , with necessary CI or MS brackets, inside
Bottole trap fittings, 40 mm dia outlet, Testing & installation as per drawing & specification. For
Code no.: 26474IN-ER-0, Sensor - 24199IN-C01-CP
Providing & Fixing Stainless steel single Kitchen Sink. 50 mm dia. CP waste coupling, CP
Bottle trap, Testing & installation as per drawing & specification. Make Nirali 600 X 400 MM
Providing & Fixing C.P. Angle valve with C.P. copper connecting pipe 450 mm long and nuts,
washer and brass flange complete complete job finish work. (code no K-76389IN-9-CP)
Providing & Fixing C.P. Wall Mount Cock (Cold Only) for Basin, install with Brass Threaded
fittings, complete complete job finish work. (Code no K-33103IN-4ND-CP)
Sr.No. Item Description Unit Quantity Rate Amount
Providing & Fixing C.P. Pillar Cock for Basin, install with Brass Threaded fittings, complete
complete job finish work. ( Make Jaquer)
Providing & Fixing C.P. Sink Cock Floor mount for Kitchen Sink, install with Brass Threaded
fittings, complete complete job finish work. ( Make Jaquer)
Providing & Fixing Health Faucet with C.P. connecting pipe 1000 mm long and nuts, washer
and install with Brass Threaded fittings, complete job finish work. (Kohler make Deco model )
Providing & Fixing C.P. Single Lever Diverter for Hot & Cold Water Mixer In Bath Area
1.12 install with Brass Threaded fittings, Concealed paerts complete job finish work. (Code no K-882IN- Nos. 3.00 5,454.00
Providing & Fixing C.P. Bath Spout with button attachment install with Brass Threaded
fittings, complete job finish work. (Code no. K-20077IN-CP)
Providing & Fixing C.P. Overhead Shower with Shower Arm install with Brass Threaded
fittings, complete job finish work. (Code no K-22645IN-CP)
Providing & Fixing C.P. Hand Shower with shower rail install with Brass Threaded fittings,
complete job finish work. (Code no K-16359IN-A-CP)
Providing & Fixing C.P. Bib Cock at Wash Area install with Brass Threaded fittings, complete
job finish work. (code no K-16093IN-4-CP)
Providing & Fixing C.P. Two Way Bib Cock at Wash Area install with Brass Threaded fittings,
complete job finish work. (code no K-16094IN-4-CP)
Providing and fixing C.P. brass towel rail comlete with C.P. brass brackets fixed to wooden
plugs with C.P. brass scews.(B) 600mm x 20mm size.
1.20 Providing and fixing toilet paper holder. (A) C.P. Brass Nos. 68.00 418.68
1 Sub Total of Sanitary Fixtures and CP Fitting and Work
2.0 Internal & External Drainage
Fixing, jointing, testing and commissioning of Low Noise Sound proof pipe for Soil & Waste
upto 160mm dia. including all necessary fittings such as 45 or 90 deg. bends, Tee's, Y's, access
2.1 pipe with rubber ring jointing. Fixing at wall / ceiling level supported by galvanized brackets &
pvc coated clamps, Air vent cowl & hangers etc. (Inside the Building i.e. Internal Toilet
Draiange Line - Hanging Line)
SOIL & WASTE RING FIT - for Auditorium
2.1.1 40 mm Dia for Basin Rmt 65.00 494.90
2.1.2 50 mm Dia for urinal & Sink Rmt 62.00 601.96
2.1.3 75 mm Dia Rmt 0.00 742.35
2.1.4 110 mm Dia Rmt 412.00 1,290.78
Sr.No. Item Description Unit Quantity Rate Amount
2.1.5 160 mm Dia Rmt 1,696.80
Providing and fixing to wall ceiling and floor 10.0 Kg.F/Cm2 working pressure polythene pipes of
the following outside Dia. Low densidy, complete with
special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and
floor.( as per drawing work)
SOIL & WASTE & RAIN WATER - solvent fit
2.2.1 40 mm Dia Rmt 10.00 125.57
2.2.2 50 mm Dia Rmt 10.00 167.03
2.2.3 75 mm Dia Rmt 10.00 277.43
2.2.4 110 mm Dia Rmt 10.00 336.24
Fixing, jointing, testing and commissioning of UPVC Pipe Type-B Confirming to 13592-1992,
for Soil & Waste / Rain Water / Air Vent Line upto 200mm dia. including all necessary fittings
such as 45 or 90 deg. bends, Tee's, Y's, access pipe with rubber ring jointing. Fixing at wall /
ceiling level supported by galvanized brackets & pvc coated clamps, Air vent cowl & hangers etc.
(Inside the Building i.e. External Building Tower Duct Line / Rain water Line / Basement
Hanging Line)
SOIL & WASTE & RAIN WATER - RING FIT
2.3.1 75 mm Dia Rmt 22.00 277.43
2.3.2 110 mm Dia Rmt 116.00 835.15
2.3.3 160 mm Dia Rmt 90.00 831.22
Fixing SWR quality, heavy duty, Silensio heavy Duty ‘P’ Trap of Brand or equivalent make,
with Sq. 150 x 150 mm CP pressed steel Grating, to ceiling and floor, including cutting the walls
and floors and making them good, testing, etc., complete having 110mm inlet and 110mm outlet. It
shall have minimum water seal of 50mm Testing & installation as per drawing & spefication.
Fixing SWR quality, heavy duty, Height Riser for Basin Pipe inlet connection of Brand or
2.5 equivalent make, 40 & 50mm inlet and 110mm outlet. Testing & installation as per drawing & Nos. 25.00 404.00
spefication.
Fixing SS 304 material Jali 100 x 100 in Balcony area of Brand or equivalent make, Testing &
installation as per drawing & spefication.
Fixing Cleaning cap for maintenance purpose in hanging draiange line in ceiling & basment area
PP Material
2.7.1 110 mm Dia Nos. 5.00 354.51
2.7.2 160 mm Dia Nos. 8.00 683.77
2.8 CORE CUTTING WORK SLAB & BEAM (APPROX QTY.)
2.8.1 50 mm Nos. 5.00 303.00
2.8.2 75 mm Nos. 5.00 454.50
Sr.No. Item Description Unit Quantity Rate Amount
2.8.3 110 mm Nos. 4.00 656.50
2.8.4 125 mm Nos. 136.00 656.50
2.8.5 150 mm Nos. 10.00 757.50
2.8.6 200 mm Nos. 10.00 858.50
Supply installation, testing and commissioning in position Popypropelene Vent Cowl in dome
2.9 shaped above Terrace Level piping, for necessary vent as per direction of engineer. (Work within
Plumbing shaft)
2.0 Sub Total of Internal & External Drainage Work
3.0 Internal Water Supply
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE
having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore
tube fittings and clamps including making good the wall, ceiling and floor etc. complete.[A]
mm.Testing & installation as per drawing & spefication.
(CONCEALED PIPE LINE) HOT & COLD
3.1.1 1/2" dia (15 mm) Rmt 166.86
3.1.2 3/4" dia (20 mm) Rmt 172.00 205.00
3.1.3 1" dia (25 mm) Rmt 126.00 249.72
3.1.4 1.1/4" dia (32 mm) Rmt 40.00 333.66
Fixing, Hot water insulation 9mm thick Nitrile rubber of on cPVC pipe line. Testing &
installation of pipe lines as per drawing & spefication.
Only for Concealed Hot Water Line
3.2.1 3/4" dia (20 mm) Rmt 6.00 101.00
Fixing uPVC pipes & fittings SCH 40 including all fittings including fixing the pipe with clamps
at 1.00m spacing. This includes jointing of pipes & fittings with solvent cement, The scope shall
include all required civil work to install the piping system (for water distribution). Testing &
installation of pipe lines as per drawing & spefication.
( GARDEN / TERRACE LELVEL / DUCT PIPE LINE / BASEMENT)
3.3.1 1/2" dia (15 mm) Rmt 20.00 72.65
3.3.2 3/4" dia (20 mm) Rmt 20.00 303.00
3.3.3 1" dia (25 mm) Rmt 218.00 91.84
Sr.No. Item Description Unit Quantity Rate Amount
3.3.4 1.1/4" dia (32 mm) Rmt 26.00 119.15
3.3.5 1.1/2" dia (40 mm) Rmt 50.00 148.12
3.3.6 2" dia (50 mm) Rmt 186.00 195.67
3.3.7 2.1/2" dia (65 mm) Rmt 10.00 898.90
Fixing SS/Brass/Gun Metal Ball Valve, Ball valve must be having screwed ends. The ball valve
3.4 should be with stand with maximum pressure up to 16 Kg/cm2. Testing & installation of valve as
per drawing & spefication.
3.4.1 1/2" dia (15 mm) Nos. 13.00 1,005.96
3.4.2 3/4" dia (20 mm) Nos. 10.00 1,224.12
3.4.3 1" dia (25 mm) Nos. 7.00 1,606.91
3.4.4 1.1/4" dia (32 mm) Nos. 11.00 2,425.01
3.4.5 1.1/2" dia (40 mm) Duct Nos. 14.00 3,209.78
3.4.6 2" dia (50 mm) Nos. 16.00 4,355.12
3.4.7 2.1/2" dia (65 mm) Nos. 2.00 8,211.30
3.4.8 3" dia (75 mm) Nos. 0.00 13,676.41
3.4.9 4" dia (110mm) Nos. 0.00 19,586.93
Supplying, fitting & fixing PP Non return valve as per relavant standard , tested to 10 kg/sq.cm
etc. complete.
3.5.1 2" dia (50 mm) Nos. 6.00 2,626.00
3.0 Sub Total of Internal Water Supply Work
Total of Internal Plumbing Work
AHMEDABAD MUNICIPAL CORPORATION
Construction of Auditorium At TP No 124C, FP No 31 (Social Infrastructure), in Thhakarnagar Ward, North Zone, Ahmedabad.
BOQ for External Plumbing Work
Sr. Item Description Unit Qty Rate Amount
4 External Drainage Line Network
Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S. class NP2 of
4.1 the following internal diameter with collars and butt ends prepared for collar joints including testing of joints
4.1.1 150 mm Rmt 248.67
4.1.2 250 mm Rmt 200.00 348.04
4.1.3 300 mm Rmt 20.00 665.48
4.2 MAN HOLE WORK
Constructing brick masonry chamber for underground C.I. Inspection chamber and bends with bricks having
crushing strength not less than 35Kg/Cm2 in C.M. 1:5 C.I. cover with frame (Light duty) 455mm x 610mm intenal
dimensions total weight of cover with frame to be not less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of frame 15Kg.
4.2.1 ) (R.C.C. top slabe with 1:2:4 mix (1-cement :2-coarse sand :4-graded stone aggregate 20mm size) foundation Nos. 2.00 3,660.76
concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished smooth with a floating coat of neat
cement on walls and bed concrete etc. complete.(ii) Inside dimensions
500mm x 700 mm and 450mm deep for pipe line with one or two inlets.
Constructing brick masonry chamber for underground C.I. Inspection chamber and bends with bricks having
crushing strength not less than 35Kg/ Cm2 in C.M. 1:5 C.I. cover with frame (Light duty) 455mm x 610mm intenal
dimensions total weight of cover with frame to be not less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of frame 15Kg.
4.2.2 ) (R.C.C. top slabe with 1:2:4 mix (1-cement :2-coarse sand :4-graded stone aggregate 20mm size) foundation Nos. 10.00 7,180.44
concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished smooth with a floating coat of neat
cement on walls and bed concrete etc. complete.(iii) Inside dimensions 600mm x 850 mm and 450mm deep for pipe
lines with three or more inlets.
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-cement :2-coarse sand : 4-graded stone aggregate 20mm
nominal size) foundation concrete 1:3:6 mix (1-cement : 3- coarse sand :6-Brick bats 40 + 50mm size) inside
plastering 15mm thick with Cement Mortar 1:3 (1-Cement : 3-coarse sand) finished with a floating coat of neat
cement and making channels in cement concrete 1:2:4 mix (1- Cement :2-Coarse sand :4-stone aggregate 20mm
4.2.3 nominal size) finished smooth complete including curing and festing (i) Inside size 900mm x 1200mm and 1.5M. Nos. 4.00 19,330.46
deep including C.I. cover with frame size 560mm diameter total weight of cover and frame to be not less than
kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm thick walls of brick msonry using brick having
crushing strength not less than 35Kg. / Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse sand) (2) B type depth
1.50 Metre for 150mm diameter sewer.
Sr. Item Description Unit Qty Rate Amount
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-cement :2-coarse sand : 4-graded stone aggregate 20mm
nominal size) foundation concrete 1:3:6 mix (1-cement : 3- coarse sand :6-Brick bats 40 + 50mm size) inside
plastering 15mm thick with Cement Mortar 1:5 (1-Cement : 5-coarse sand) finished with a floating coat of neat
cement and making channels in cement concrete 1:2:4 mix (1- Cement :2-Coarse sand :4-stone aggregate 20mm
4.2.4 nominal size) finished smooth complete including curing and festing (i) Inside size 900mm x 1200mm and 1.5M. Nos. 1.00 23,441.74
deep including C.I. cover with frame size 560mm diameter total weight of cover and frame to be not less than
kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm thick walls of brick msonry using brick having
crushing strength not less than 35Kg. / Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse sand) (3) C type depth
2.25 Metre for 150mm diameter sewer.
Providing and fixing S.W. gully trap with C.I. grating brick masonry chamber and water tight C.I. cover with frame
of 300mm x 300mm size (inside) with standard weight.(i) Square mouth traps.(B) 150mm x 100mm size P or R type
4.3.1 300 x 300 mm chamber with 160 x 200 mm size `P’ trap. Nos. 10.00 1,246.92
4.4 Fixing Manhole cover RCC cement heavy duty
4.4.1 455 x 610 mm size having weight Capacity 10 Ton Minimum - FRP Nos. 820.84
4.4.2 500 x 700 mm size having weight Capacity 40 Ton Minimum - RCC Nos. 3,535.00
4.4.3 600 x 850 mm size having weight Capacity 40 Ton Minimum - RCC Nos. 10.00 4,949.00
4.4.4 900 x 900 mm size having weight Capacity 40 Ton Minimum - RCC Nos. 7,575.00
4.4.5 900 x 1200 mm size having weight Capacity 40 Ton Minimum - RCC Nos. 5.00 9,746.50
4.4.6 300 x 300 mm Nos. 400.58
(Quanity changes possible as per final drawing)
Construction work of Storm Water Channel in Road level area with RCC base 'C'' type channel with proper line
& slope as per design, Top side framing cover fitting FRP or MS powder coating Jali as per design,
4.4.1 Width 300 for Basement Meter 250.00 505.00
4.4.2 Width 450 for Basement Meter 270.00 505.00
Extra over items 24.44 for every additional depth of 0.1M. of part thereof beyond 450mm depth for Brick masonry
chamber.(i) for 455mm x 610mm size.
Extra over items 24.44 for every additional depth of 0.1M. of part thereof beyond 450mm depth for Brick masonry
chamber.(ii) for 500mm x 700mm size.
Extra over items 24.44 for every additional depth of 0.1M. of part thereof beyond 450mm depth for Brick masonry
chamber.(iii) for 600mm x 850mm size.
4 Sub Total of External Drainage Line Work
5 Plants & Equipments
Supply, installation, testing & commissioning of Auto Type Water Level Controller for OH Water tank
controllging system with switches, hardwares, interlocking with panel, etc.
Installing, testing and commissioing of Submersible Pump in UG Water Tank area with suction & delivery pipe
line, ball valves & check valves etc., complete., (250 LPM X 50 METER HEAD)
5.3 HYDROPNEUMATIC SYSTEM FOR DOMESTIC WATER
Sr. Item Description Unit Qty Rate Amount
Installing, testing and commissioing of Hydropneumatic System comprising of Vertical multistage / horizontal
centrifugal Pumps with CI casing, SS impeller, SS Shaft and driven by 415 V AC, 3 phase, 50HZ., motor running at
2900 rpm speed and shall be supplied with all accessories viz., base plate, coupling, motor, VFD based control
panel, dry run & overload protection, cabling up to panel, earthing, GI medium duty suction, delivery & header
pipes, pressure gauge, pressure switches, pressure transmitter, suction ball valves & delivery ball valves & check
valves etc., complete.
1 Working + 1 Stand by sytem for Common area GF level Water Distribution, Flow Rate - 200 LPM @ 25 Meter
Head 1.5 HP per Pump
Installing, testing and commissioing of Mud Pump in Basement sump area with suction & delivery pipe line, ball
valves & check valves etc., complete., 1 Working + 1 Stand by (10000 LPH X 15 METER HEAD) 1.5 HP per Pump
Installing, testing and commissioing of PVC Water Tank at Terrace level with Controlc cock fitting, Inlet, Outlet,
5.5 tnak connection, drain, overflow all do with necessary pipe & fittings. Charges incuded lifitng at GF to Terrace Set
5000 Liter Tank 4 layer white Color for LH Side Toilet Set 3.00 15,150.00
5000 Liter Tank 4 layer white Color for RH Side Toilet Set 3.00 15,150.00
Percolation Well: Boring and Sinking 150 mm diameter casing pipes up to minimum 120.00 meter depth , as per
specifications with any approved system like Auger, Derrick etc. including installation of other equipments such as
Pumps, Water Tanks, etc. complete and thereafter withdrawal and removal of the system etc. complete and clearing
the site on completion.
5 Sub Total of Plants and Equipments
Total Amount of External Plumbing Work
Total Amount of External Plumbing Work
Construction of Auditorium At TP No 124C, FP No 31 (Social Infrastructure), in Thhakarnagar Ward, North Zone, Ahmedabad.
BOQ of Electrical Work
Qty. Description of Item Unit Rate Amount
Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr
length , in below type of pipe erected with 6A Modular type switch / bell push & accessories and earth continuity of following type, erected on PVC / Metallic/Wooden box, single
1 1-2-1. 173.0 mounting base frame covered with textured/metallic/white front plate modules erected on / in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / Point 485.81
H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete Cat-III
Point wiring for secondary light point with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires, in
below type of pipe to be erected complete with earth continuity and necessary connection with primary light with accessories erected on Metal / PVC / wooden box covered with
2 1-1-4. 575.0 Point 167.66
mm thick PC(Polycarbonate) / Acrylic sheet for open / concealed wiring. with necessary Lamp holder / ceiling rose / H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete Cat-III
Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (green) both are of .ISI marked 1.1 KV grade FRLS PVC insulated multi strand
copper wires erected in below type of pipe with 6A Modular type switches and following type of accessories erected on PVC / Metallic / Wooden box, single mounting base frame
3 1-2-5. 25.0 covered with textured / metallic/white front plate modules erected on / in wall / ceiling as per pipe erected. with necessary batten / angle holder or ceiling rose or H.D.Connector as Point 603.98
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete
Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of .ISI marked 1.1 KV Grade FRLS PVC insulated multi strand copper wires up to 10 mtr length,
in below type of pipe erected with 6A Modular type switch and hum free EME step type electronic fan regulator mounted and accessories with earth continuity of following type
4 1-2-2. 38.0 erected on PVC / Metallic / Wooden box, single mounting base frame covered with textured / metallic / white front plate modules erected on / in wall / ceiling as per pipe erected. with Point 674.68
necessary ceiling rose / H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete Cat-III
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in
below type of pipe erected complete with Modular type switch & 5 pin Plug erected on PVC / Metallic / Wooden box covered with appropriate front plate modules erected on / in wall
5 1-2-3 -I. 45.0 / ceiling as per pipe erected with following type of accessories. Point 510.05
[I] For 6A Plug and 6 a switch with 2-1.5 sq.mm Cu. Wire from nearby switch board / mcb db board (f) with
medium class Rigid PVC pipe and accessories erected concealed in wall / ceiling complete Cat-III
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in
below type of pipe erected complete with Modular type switch & 5 pin Plug erected on PVC / Metallic / Wooden box covered with appropriate front plate modules erected on / in wall
6 1-2-3 -ii. 11.0 / ceiling as per pipe erected with following type of accessories Point 745.38
[II] For 16A Plug and 16 amp switch with 2-2.5 sq.mm Cu. Wire from mcb db board.
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete Cat-III
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in
below type of pipe erected complete with Modular type switch & 5 pin Plug erected on PVC / Metallic / Wooden box covered with appropriate front plate modules erected on / in wall
7 1-2-3 -ii. 12.0 / ceiling as per pipe erected with following type of accessories Point 745.38
[II] For 16A Plug and 16 amp switch with 2-2.5 sq.mm Cu. Wire from mcb db board. (FOR UPS)
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete Cat-III
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in
below type of pipe erected complete with Modular type switch & 5 pin Plug erected on PVC / Metallic / Wooden box covered with appropriate front plate modules erected on / in wall
8 1-2-3 -iii. 4.0 / ceiling as per pipe erected with following type of accessories Point 871.63
[III] For 16A Plug and 16 amp switch with 2-4 sq.mm Cu. Wire with 2.5 sq.mm ( green) earthing wire from mcb d b board.
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete Cat-III
Point wiring for on board Looped Plug with 6A Modular type switch & 5 pin socket erected on PVC / Metallic / Wooden box, single mounting base frame covered with textured /
9 1-2-4. 33.0 Point 257.55
metallic / white front plate modules erected on / in wall / ceiling with following type accessories. Cat-III
Providing following type of Modular Type Accessories mounted with PVC / metallic / Wooden box, single mounting base frame covered with textured / metallic / white front plate
10 1-2-6. 1.0 modules erected with necessary connections as per site situation directed by Engineer In charge. (4) TV Co- Each 160.59
axial Socket outlet Cat.III
Qty. Description of Item Unit Rate Amount
Providing following type of Modular Type Accessories mounted with PVC / metallic / Wooden box, single mounting base frame covered with textured / metallic / white front plate
11 1-2-6. 50.0 modules erected with necessary connections as per site situation directed by Engineer In charge. (7) Blank Each 25.25
Plate Single Cat.III
Providing following type of Modular Type Accessories mounted with PVC / metallic / Wooden box, single mounting base frame covered with textured / metallic / white front plate
12 1-2-6. 17.0 modules erected with necessary connections as per site situation directed by Engineer In charge. (8) Each 160.59
Computer RJ-45 socket Cat.III
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes
13 1-3-2. 1000.0 fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed. Mtr 33.33
Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on
wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size
(A) with medium class Rigid PVC pipe and accessories
(a) 2 wire 1.5 sq. mm
Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in / flushed on wall
/ ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size
(A) With medium class Rigid PVC pipe and accessories
(b) 2 wire 2.5 sq. mm
providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with
sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size
(A) with medium class Rigid PVC pipe and accessories
(a) 2 wire 4 sq. mm
Providing & erecting Switch board for Computer or electric apparatus consisting of following modular type accessories mounted with PVC / Metallic concealed / open box with
single mounting base frame covered with textured / metallic /white front plate, modules erected with necessary connections as directed
1 no. 6A/16A universal plug-switch combined.
17 1-6-2.B 17.0 Each 1,133.22
3 nos. 6A Switch
3 nos. 6A 5 pin Plug
For Modular Type Accessories Cat. III
Lighting Fixtures ,Fan & other items
Providing and erecting decorative wall bracket fittings complete with LED lamp and rust free fittings components mounted in chrome finish housing with holder,clear/opaque glass
diffuser complete erected with lead wires with minimum 15 wattage capacity as per instruction engineer incharge/architect/authority.cat-III
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet
Steel conforming to IS: 513/CRCA/ aluminium die cast powder coated and high U.V. & corrosion resistance with diffuser with company mark/name 160V to 270V, Power Factor
more than 0.95, THD < 15%,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 %
capacity between the ranges shown.)
(A) Tube Light with integral driver
(v) 36-40 Watts, Surge-2 KV, IP-20, conventional 4 feet
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet
Steel conforming to IS: 513/CRCA/aluminium pressure die cast powder coated and high U.V. & corrosion resistance with diffuser housed in aluminium casted body with company
160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
20 2-15-3-A 64.0 Luminaire efficacy> 85 lumens/watt , Each 220.18
LED driver efficiency > 85 %
capacity between the ranges shown.)
(A) Square/ Circular shaped Surface/Recessed Mount Downlight with provision for spring loaded mounting clips complete.IP20
(i) 5-9 watts,Surge-2 KV cat-III
Qty. Description of Item Unit Rate Amount
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet
Steel conforming to IS: 513/CRCA/aluminium pressure die cast powder coated and high U.V. & corrosion resistance with diffuser housed in aluminium casted body with company
160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
21 2-15-3-A 50.0 Luminaire efficacy> 85 lumens/watt , Each 427.23
LED driver efficiency > 85 %
capacity between the ranges shown.)
(A) Square/ Circular shaped Surface/Recessed Mount Downlight with provision for spring loaded mounting clips complete.IP20
(ii) 11-15 watts, Surge-2 KV cat-III
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet
Steel conforming to IS: 513/CRCA/aluminium pressure die cast powder coated and high U.V. & corrosion resistance with diffuser housed in aluminium casted body with company
160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
22 2-15-3-A 255.0 Luminaire efficacy> 85 lumens/watt , Each 589.84
LED driver efficiency > 85 %
capacity between the ranges shown.)
(A) Square/ Circular shaped Surface/Recessed Mount Downlight with provision for spring loaded mounting clips complete.IP20
(iii) 16-20 watts, Surge-2 KV cat-III
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet
Steel conforming to IS: 513/CRCA/aluminium pressure die cast powder coated and high U.V. & corrosion resistance with diffuser housed in aluminium casted body with company
160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
23 2-15-3-A 274.0 Luminaire efficacy> 85 lumens/watt , Each 758.51
LED driver efficiency > 85 %
capacity between the ranges shown.) (A) Square/ Circular shaped
Surface/Recessed Mount Downlight with provision for spring loaded mounting clips complete.IP20
(iv) 22-24 watts, Surge-2 KV cat-III
Supplying and erecting led lamps with following wattage capacity of 220 to 240 voltage, minimum 15000 burning hours life, 500 V in built-surge protection,Polycarbonate diffuser,
mounting suitable for E14 / E27 / B22 lamp holders, pf >=
(A) LED Lamps integral type, with PC diffuser suitable LAMP holder
(iv) 16 to 20 watts Cat-III
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet Steel
conforming to IS: 513/CRCA/ aluminium die cast powder coated and high U.V. & corrosion resistance with diffuser with company mark/name 160V to 270V, Power Factor more than
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 %
capacity between the ranges shown.)
(A) Tube Light with integral driver
(i) 5-10 Watts, Surge-2 KV, IP-20, conventional 1 to 2 feet cat-iii
Qty. Description of Item Unit Rate Amount
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet Steel
conforming to IS: 513/CRCA/aluminium pressure die cast powder coated and high U.V. & corrosion resistance with diffuser housed in aluminium casted body with company
160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
26 2-15-3 250.0 Luminaire efficacy> 85 lumens/watt , Each 573.68
LED driver efficiency > 85 %
capacity between the ranges shown.)
(G) Step Light having Aluminium die cast and ABS Plastic material.
(i) 5 watts, Direct/Indirect luminaire Cat-lll
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet Steel
conforming to IS: 513/CRCA/aluminium pressure die cast powder coated and high U.V. & corrosion resistance with diffuser housed in aluminium casted body with company
160V to 270V,Power Factor more than 0.9, THD < 15 %,
CCT 3000 K to 6500K,
27 2-15-3 100.0 Luminaire efficacy> 85 lumens/watt , Mtr. 220.18
LED driver efficiency > 85 %
capacity between the ranges shown.)
(D) LED Strip Light
(ii) Minimum 7.2W -240 LED per meter,(2 wire, IP-65) with non integral suitable Driver complete CAT-III
SITC of BIS approved LED street light luminaire with system power 80W (± 5%) , available in Natural White color temperature (4000K ± 355K as per ANSI C78:377A), CRI≥80,
SDCM<3, LEDs used should have a life of 100000 burning hrs. & Lumen maintenance as per L90. The Luminaire System efficacy should be of ≥160LPW. LED Luminaires must be
equiped with with preprogrammed time based factory set dimmable driver, registered for Street Lighting under BIS- CR Compulsory Registration Scheme. The fixture housing must be
Made of LM 6/ADC 12 PDC Aluminium housing for rapid thermal management & Powder coated by Corrosion resistant Nano coating powder coating process. Proper technical quality
documents for Nano-Technology powder coating should be submitted by OEM compulsarily. Luminaire must have a Ingress protection of IP66 and Impact Resistance of IK08 for
housing and optical impact to be IK 09. The fixture should have an UV stabilized, Injection moulded special PC cluster lens optics ensuring low glare & best in class uniformity. Light
Engine PCB should be Metal Core PCB made of high grade Al 5052 with ≥70 micron copper thickness & 2 W/mK thermal conductivity for better thermal maintanance for light
Engines. Luminaire should have minimum or more than nett weight of 3.25 k.g. The Luminaire must have thermally Isolated Driver and Optical compartments separated by natural air
gap for efficient heat management and to ensure sustainable operation with dual air cross conductivity. Both luminaire housing and optical compartment should have OEM logo
embossed / engraved (no stickering is allowed). Driver must be placed in a separate hingeable bottom openable compartment which is replaceable in the field condition with minimum
Tools. The light engine should have a suitable secondary optics to deliver desired light distribution to meet the illuminance criteria. The Junction temperature of LED shall be <
28 RA-1 30.0 Each 14,645.00
degree Celsius. The luminaire must have Integral encapsulated high efficiency electronic driver having a Aluminium extrusion housed construction with a wide rated voltage range of
140-270V, Driver efficiency >85%, power factor > 0.95, THD <10%. The driver must be compatible with Inbuilt surge protection of 6KV and upgraded with integrated IP67 protected
SPD of 20KV/10KA surge protection within the driver compartment. Luminaire should be with basic protections like short circuit, Mis wiring , reverse polarity with LM 79, LM 80, &
TTC certificates will be provided from a NABL accredited lab. Luminaire performance & Safety should comply to IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5,
EMC : EN 55015. All certificates supporting the technical parameters of luminaire & OEM scope must be submitted. The BIS of luminaire should carry own manufacturing facility of
OEM. Dedicated vendor / sub-vendor facilities are not accepted. Manufacturer should have their own NABL accredited testing laboratory for EMI-EMC test, Vibration compatibility
test, Salinity spray test, wind load pressure test, IP / IK test, in house powder coating facility, in house casting plant, robo-photometric laboratory and in house driver manufacturing
facility, SMT line in India. OEM should have own manufacturing facility for quoted LED fixtures in India which should be functional for last 10 years and should have dedicated
official team for after sales and service support based out of Gujarat. Official undertaking certifying OEM's lighting sales, design & service maintenance office presence in Gujarat must
be submitted. Manufacturer should have Certification pertaining to product Design Registration, CE certifications, ROHS compliant, BIS certificate for drivers and luminaires
respectively. All above technical points should be compulsarily backed up by supporting documents and need to submitted in the tender in hard copy and soft copy.
Providing & erecting Approved make Power Saving 50 Watt Ceiling Fan with double ball bearing ISI mark with Condenser 230 volt A.C. 50 Hz 1200 mm sweep complete having
29 5-1-6. 38.0 blades with aluminium blades with, canopy & 30 cm. down rod erected with earthing. (Make shall be approved by Engineer in charge) Each 1,948.29
(B) 1200 mm Sweep (48")
30 5-2-1. 38.0 Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe down rod erected duly painted for fan complete with proper insulation without leakage and earthing. Each 108.07
31 5-2-2. 38.0 Supplying & erecting Fan Hook of 10 mm M.S. Round bar grouted in RCC slab with Making the site as original. Each 43.43
Qty. Description of Item Unit Rate Amount
32 5-3-3. 13.0 Supplying & erecting approved make low noise decorative exhaust fan having square frame ABS body with inbuilt lowers & square frame.For 200mm with 1350 RPM cat-ii Each 1,703.87
Supplying and erecting approved make double ball bearing oscillating type Heavy duty bracket fan with Aluminium Blades A.C. 23OV. 50cy/s wall mounted with height adjustment and
rotary tilting device complete with guard, wall bracket,mounting accessories as directed. (A) 450mm
Street Light poles & other items
Supply of approved make frp/grp pole having followiing specifications :
FRP/GRP pole made by centrifugal moulding process using thermoset resin polyester/epoxy resin system having minimum glass content 45.0%.The pole should be in one pieceand
tapered round in shape,having smooth outside surface finish and should be totally fre from corrosion as well as non conductive and shock proof. Pole should be provided with FRP/GRP
base bracket dully fabricated from metal(M.S) and dully claded with FRP/GRP material to avoid any metal exposer and painted with PU paint.
Pole should mechanical properties i.e 1. Specfic gravity (ASTM D 792) 1.3‐1.8 Kg/m3, 2. Glass Content % by weight (ASTM D 2584) 45.0 ‐55.0%, 3. Water absorption (ASTM D 570)
<0.5%, 4. Tensile Strength(ASTM D 638) 200+/‐50Mpa, 5. Flexural strength (ASTM D 790) 250+/‐50Mpa, 6. Compressive Strength (ASTM D 695) 200+/‐50MPa, 7. Yeild
Strength(ASTM D638) 250 +/‐50MPa.
34 6-1-7(A) 30.0 Pole should be flame retardant as per IS 6746.Resin used shall be UV resistance and pigmented. Pole should be painted with first coat of epoxy primer and then two coat of highly Each 16,983.15
weather resistance polyurethen paint to ensure proper addhesion of the paint.Minimum thickness shall be 80 to 100 micron.Defelection of the pole shall not exceed more than 10.0 % of
the length of the pole for the given load.Pole should be generally made as per the dimensional data,performance criteria and some interchagebility features of poles as per the standard
ANSI C123.20 latest version of ASTM D 923/01 including cable termination box with necessory accessories.The size of pole and type of installation with foundation , Anchor Base &
Internal junction box as per the manufacturer details and site requirement.
(3) 'B' class (Heavy Duty) frp/grp pole suitable for base plate mounting
[D] Overall Length of 6.0 meter, Average thickness : 7mm, Top/Bottom Outside Dia. 76/176mm +/‐2.Weight of Pole 25.0 Kg approx. (Without base) Metal Anchor Base dully frp
claded (Size : 340 Ø * 12mmthk , Mounting hole PCD 285mm * 6 nos. of 20 Ø hole)
35 6-3-1. 30.0 Providing and erecting C.I./M.S. flange type base plate of 300mm x 300mm x 6mm Each 240.38
Supplying & erecting approved make SMC press moulded composite FRP. loop-in, loop-out approx. 2mm thick box complete with Bakelite connector strip 5way (3P+N+E), DIN rail
for mounting mob & hinged doors as per requirement having locking arrangements with mounting clamp with nuts, bolts & washers suitable for erection on pole with cable clamps&
earth bolt of following size of box.
(A) 300mm x 200mm x 100mm [deep]
Providing FRP/GRP arm bracket of having 15˚ arm with 50 mm OD pipe *5 mm thk,1000mm long from pole centre
37 6-1-7 (B) 30.0 Each 29,840.00
(A) Single arm bracket
Panel & Switchgear
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 25 KA. at 415 V,having normal current rating up to 25 A to 100A.
38 3-4-1. 50.0 with Fixed thermal & magnetic release suitable to work on A.C. supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing. Each 6,173.12
ICS=100% of ICU only Cat III
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having Normal current rating 200A. with variable
39 3-4-3. 5.0 Thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S.housing. ICS=100% Each 16,221.61
of ICU only Cat III
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. and above at 415 V. having normal current rating 250A. with
40 3-4-4. 2.0 variable thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing. Cat Each 20,946.39
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 50 K.A. and above at 415 V having normal current rating up to 630A .
41 3-4-6. 4.0 with variable thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing. Each 28,173.95
Providing and erecting Approved make standard manually operated fixed type 4 Pole Air circuit breaker. Having following kA breaking capacity with ICU=ICS=ICW (1 sec), Vsr=690
v, Ui=1kv with following type of relay and accessories.
(2) with microprocessor Release with over load, short circuit, earth fault protection (L.S.I.G.) and metering display in modular design with LED display and Test Trip button facility,
CTs and auxiliary contacts, of following current ratings. (A) 800Amp 50kA Cat III
Providing and erecting Approved make Three pole moulded case circuit breaker having breaking capacity/strength ICU of 35 K.A. at 415 V. having normal current rating 125A .with
Fixed thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing. Cat III
Qty. Description of Item Unit Rate Amount
Providing and erecting Approved make standard manually operated fixed type 4 Pole Air circuit breaker. Having following kA breaking capacity with ICU=ICS=ICW (1
sec),Vsr=690 v, Ui=1kv with following type of relay and accessories.
44 3-5-2. 1.0 (2) with microprocessor Release with over load, short circuit, earth fault protection (L.S.I.G.) and metering display in modular design with LED display and Test Trip button facility, Each 68,364.88
CTs and auxiliary contacts, of following current ratings.
(A) 800Amp 50kA Cat III
Supply of Approved make Iron Clad or metal clad four pole change over switch 415V. confirming to IS of following capacity
PANEL MOUNTING BUSBARS
Supplying and erecting triple pole & neutral 440V/ 500V panel mounting Aluminium Busbars with four equal Nos. of bus having current density not more than 0.8 Amp. / sq.mm
(Rated current / cross section area) duly wrapped with colour insulating tape for phase sequence of following current carrying capacity, erected with necessary bus bar supports
46 3-8-1. 10.0 Rn.Mtr 1,469.55
/insulators, main cable socket to each busbar,erected in existing cubical panel with necessary connections.
(C) Suitable for 300 Amp. Capacity
Supplying and erecting triple pole & neutral 440V/ 500V panel mounting Aluminium Busbars with four equal Nos. of bus having current density not more than 0.8 Amp. / sq.mm
(Rated current / cross section area) duly wrapped with colour insulating tape for phase sequence of following current carrying capacity, erected with necessary bus bar supports
47 3-8-1. 10.0 Rn.Mtr 2,204.83
/insulators, main cable socket to each busbar,erected in existing cubical panel with necessary connections.
(D) Suitable for 400 Amp. Capacity
Supplying and erecting triple pole & neutral 440V/ 500V panel mounting Aluminium Busbars with four equal Nos. of bus having current density not more than 0.8 Amp. / sq.mm
(Rated current / cross section area) duly wrapped with colour insulating tape for phase sequence of following current carrying capacity, erected with necessary bus bar supports
48 3-8-1. 10.0 Rn.Mtr 3,061.31
/insulators, main cable socket to each busbar,erected in existing cubical panel with necessary connections.
(E) Suitable for 630 Amp. capacity
Supplying and erecting triple pole & neutral 440V/ 500V panel mounting Aluminium Busbars with four equal Nos. of bus having current density not more than 0.8 Amp. / sq.mm
(Rated current / cross section area) duly wrapped with colour insulating tape for phase sequence of following current carrying capacity, erected with necessary bus bar supports
49 3-8-1. 10.0 Rn.Mtr 6,240.79
/insulators, main cable socket to each busbar,erected in existing cubical panel with necessary connections.
(F) Suitable for 800 Amp. capacity
Supplying and erecting triple pole & neutral 440V / 500V panel mounting Copper Busbars with four equal Nos. of electrolyte bus having current density not more than 1.6 Amp. /
sq.mm (Rated current / cross section area) duly wrapped with colour insulating tape for phase sequence of following current carrying capacity, erected with necessary bus bar supports
50 3-8-2. 20.0 Rn.Mtr 1,961.42
/insulators, main cable socket to each bar, erected in existing cubical panel with necessary connections.
(A) Suitable for 100 Amp. Capacity
Supplying and erecting triple pole & neutral 440V / 500V panel mounting Copper Busbars with four equal Nos. of electrolyte bus having current density not more than 1.6 Amp. /
sq.mm (Rated current / cross section area) duly wrapped with colour insulating tape for phase sequence of following current carrying capacity, erected with necessary bus bar supports
51 3-8-2. 20.0 Rn.Mtr 3,202.71
/insulators, main cable socket to each bar, erected in existing cubical panel with necessary connections.
(B) Suitable for 200 Amp. capacity
Providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box.
52 3-10-1-B 200.0 Each 112.11
confirming to IS 8828/1996 with ISI Mark Cat.III
Providing & erecting 240 V MCB double pole switch for motor & inductive load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following
53 3-10-2. 11.0 capacity. Each 299.97
(A) 6 to 32 Amp. Cat. III
Providing & erecting 240 V MCB double pole switch for motor & inductive load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following
54 3-10-2. 38.0 capacity. Each 330.27
(B) 40 Amp. Cat. III
Providing and erecting 415 Volt MCB four pole motor & inductive load (C Curve) having 10 KA Breaking capacity and confirms to IS : 8828 in existing metal box having following
55 3-10-5. 3.0 capacity. Each 668.62
(B) 40 Amp. Cat III
Providing and erecting 415 Volt MCB four pole motor & inductive load (C Curve) having 10 KA Breaking capacity and confirms to IS : 8828 in existing metal box having following
56 3-10-5. 5.0 capacity. Each 737.30
(C) 63 Amp. Cat- III
Providing & erecting 415 V MCB three Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity
(A) 6 to 32 Amp. Cat. III
Providing & erecting 415 V MCB three Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity.
(B) 40 Amp. Cat.III
Qty. Description of Item Unit Rate Amount
Providing & erecting 415 V MCB three Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity
C) 63 Amp. Cat.III
Providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation on
single phase 240 V, 50Hz. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. rating erected as
(i) 25 Amps.DP Cat. III
Providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation on
single phase 240 V,50Hz. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. rating erected as
(ii) 40Amps. DP Cat. III
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 &
3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) suitable for
61 3-11-5-A 2.0 (A) single phase incoming and horizontal single phase outgoing Each 885.77
(b) sheet steel double door (IP-43)
(ii) 6 way
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 &
3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) suitable for
62 3-11-5-B 4.0 (B) three phase incoming and single phase horizontal type outgoing Per phase isolation type (PPI) Each 3,412.79
(b) sheet steel double door
(iii) 8 way
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 &
3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) suitable for
63 3-11-5-B 4.0 (B) three phase incoming and single phase horizontal type outgoing Per phase isolation type (PPI) Each 3,874.36
(b) sheet steel double door
(iv) 12 way
Supplying & erecting in earthpit of minimum bore dia. 225mm size approved make Safe Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of
corrosion free hot dipped G.I.Pipes having Outer pipe dia of 80 mm having 80-200 Micron galvanising, Inner pipe dia of 40 mm having 200-250 Micron galvanising, connection
terminal dia of 14 mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications with chamber and
heavy duty cover (A)(approved make OEM has to submit test certificate including value of earth resistance of installation duly stamped and signed by agency and officer Incharge has
to ensure the value of earthing resistane mentioned in test Certificate) & having back filling compound of (B) Inner chemical (CCM Compound) - Resistivity:- 0.2 ohm / meter testing
64 3-14-10 12.0 as per IEC 62561-2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2% (C) Back fill Compound :- Earthing compound should be capable to retain moisture for Nos. 10,593.89
long time Necessary test report must be submitted by Agency.
(c) For Electrical Installation covering Transformer Neutrals, Lightning arrester Earthing, A.C.Plant & Sensitive Computer System(like Automation, SCADA) i.e independent Earthing
in normal soil.
Length of Pipe : 3.00 mtrs
Back filling Compound :2 nos Bags of 25 Kg.
Providing & erecting weather proof, dust & vermin proof, floor mounted front operated indoor type cubical panel board necessary IP-42 and above protection as per approval from
engineer incharge made from 14 SWG thick CRC M.S. sheet for outer body & doors, 16 SWG thick CRC M.S.sheet for internal partitions with necessary accesories , supporting angles/
flats channel including cutting, bending, drilling, welding, riveting with internal partitions & cable alley as per requirements & instruction of engineer-in-charge with erection of
supplied switch gears, BUSBARS, suitable size of inter connecting PVC copper wire / copper-aluminium strips, rubber grommets, rib, bakelite control fuses/MCB for measuring
65 3-16-1 20.0 Sq.Mtr 19,387.96
instruments, earth bus & earth bolts, foundation flange - bolts-base Plates, sufficient nos. of hinged doors, handles with locking arrangement and rubber gasket,heavy duty end terminal
connection,danger notice board,necessary ventilation,earthing strip complete. The Panel shall be painted with epoxy powder coating.
(B) The standard companies switch gear shall be used and only manufacturers at CPRI approved factory
(ii) with 550mm depth
Providing and erecting ,Fabricating the box type items made from M.S. Sheet with A.I. supports, wings, doors, handles other hardware materials as per requirement design with
finishing by three tank powder coating processed inside and outside painted, erected as directed including minor civil work.
Qty. Description of Item Unit Rate Amount
Providing and erecting XLPE (IS:7098) (I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe
67 4-3-3. 750.0 of following size of cables Mtr 183.82
(A) 3 1/2 core 25 Sq. mm (16 Sq. mm 1/2 core)
Providing and erecting XLPE (IS:7098) (I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe
68 4-3-3. 120.0 of following size of cables Mtr 378.75
(D) 3 1/2 core 70 Sq. mm (35 Sq. mm 1/2 core)
Providing and erecting XLPE (IS:7098) (I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe
69 4-3-3. 150.0 of following size of cables. Mtr 904.96
(H) 3 1/2 core 185 Sq. mm (95 Sq. mm 1/2 core)
Providing and erecting XLPE (IS:7098) (I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe
70 4-3-3. 230.0 of following size of cables. Mtr 1,168.57
(I) 3 1/2 core 240 Sq. mm (120 Sq. mm 1/2 core)
Providing and erecting XLPE (IS:7098) (I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe
71 4-3-3. 700.0 of following size of cables. Mtr 1,407.94
(J) 3 1/2 core 300 Sq.mm (150 Sq. mm 1/2 core)
Providing and erecting XLPE (IS:7098) (I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe
72 4-3-5. 475.0 of following size of cables Mtr 153.52
(A) 4 core 16 Sq. mm
Providing and erecting XLPE (IS:7098) (I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe
73 4-3-5. 950.0 of following size of cables Mtr 190.89
(B) 4 core 25 Sq. mm
Providing and erecting XLPE (IS:7098) (I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of
74 4-4-1. 260.0 following size of cables Mtr 209.07
(B) 2 core 4 Sq. mm
Providing and erecting XLPE (IS:7098) (I)-88 ISI armoured cable multistrand / Solid Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench /
75 4-4-4. 1995.0 pipe at road crossing or floor of following size of cables. Mtr 364.61
(B) 4 core 4 Sq. mm
Providing and erecting XLPE (IS:7098) (I)-88 ISI armoured cable multistrand / Solid Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench /
76 4-4-4. 640.0 pipe at road crossing or floor of following size of cables. Mtr 510.05
(C) 4 core 6 Sq. mm
Providing and erecting XLPE (IS:7098) (I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at
77 4-4-5. 420.0 road crossing or floor of following size of cables. Mtr 676.70
(A) 4 core 10 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of
78 4-6-1. 84.0 cables. Each 33.33
(A) 2 to 4 core 2.5 / 4 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of
79 4-6-1. 14.0 cables. Each 38.38
(B) 2 to 4 core 6 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of
80 4-6-1. 14.0 cables. Each 38.38
(C) 2 to 4 core 10 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of
81 4-6-1. 14.0 cables. Each 47.47
(D) 2 to 4 core 16 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of
82 4-6-1. 58.0 cables. Each 51.51
(E) 2 to 4 core 25 Sq. mm
Providing and, fixing heavy duty flange type brass double compression type cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating
83 4-6-3. 36.0 tape etc for following size of cables. Each 66.66
(A) 3 & 1/2/4 core 25 Sq. mm
Qty. Description of Item Unit Rate Amount
Providing and, fixing heavy duty flange type brass double compression type cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating
84 4-6-3. 2.0 tape etc for following size of cables. Each 103.02
(C) 3 & 1/2 core 70 Sq. mm
Providing and, fixing heavy duty flange type brass double compression type cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating
85 4-6-3. 6.0 tape etc for following size of cables. Each 238.36
(G) 3 & 1/2 core 185 Sq. mm
Providing and, fixing heavy duty flange type brass double compression type cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating
86 4-6-3. 8.0 tape etc for following size of cables. Each 247.45
(H) 3 & 1/2 core 240 Sq. mm
Providing and, fixing heavy duty flange type brass double compression type cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating
87 4-6-3. 10.0 tape etc for following size of cables. Each 280.78
(I) 3 & 1/2 core 300 Sq. mm
Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with
88 4-7-1. 56.0 brass/cadmium plated nut bolts in an approved manner. Each 13.13
Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with
89 4-7-1. 288.0 brass/cadmium plated nut bolts in an approved manner. Each 15.15
Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with
90 4-7-1. 2.0 brass/cadmium plated nut bolts in an approved manner. Each 20.20
Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with
91 4-7-1. 6.0 brass/cadmium plated nut bolts in an approved manner. Each 25.25
Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with
92 4-7-1. 3.0 brass/cadmium plated nut bolts in an approved manner. Each 40.40
Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with
93 4-7-1. 8.0 brass/cadmium plated nut bolts in an approved manner. Each 45.45
Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with
94 4-7-1. 10.0 brass/cadmium plated nut bolts in an approved manner. Each 61.61
Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with
95 4-7-1. 18.0 brass/cadmium plated nut bolts in an approved manner. Each 80.80
Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with
96 4-7-1. 24.0 brass/cadmium plated nut bolts in an approved manner. Each 85.85
Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with
97 4-7-1. 30.0 brass/cadmium plated nut bolts in an approved manner. Each 98.98
Solder less crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with
98 4-7-2. 336.0 brass/cadmium plated nut bolts in an approved manner. Each 8.08
Cable trench
Making trench in soft soil of suitable width of 90 cms deep for laying cable or locating the fault all over the run and backfilling the same and making the surface proper. Providing and
99 4.5.1 135.0 erecting iron clad cable route marker duly marked with ELE.CABLE of size 23 cms.X 12 cms. Flushed with ground in cement foundation as directed by Engineer in charge. The width Mtr 55.55
shall be as per requirement
Covering of cable with second class bricks laid cover the cable crosswise & also on both sides with covering of 7. 5 Cms. layer of sand above & below cable (cable shall be laid in
0.9mtr.deep & 0.4 Mtr.wide trench). Where there are more than one cable in the trench on either side of the cable, 5 Cms. over lapping of bricks shall be provided.
101 6.3.8.B 10.0 Providing cement concrete.for foundation or for concrete filling in 1:2:4 ratio with 20 to 25 mm stone metal duly plastered with necessary curing for pole muffing or any other purpose. Cu.Mtr 4,511.67
Qty. Description of Item Unit Rate Amount
102 6.3.11 10.0 Providing burnt brick masonry with 1:6 cement concrete duly plastered including watering, stacking joint on exposed faces, rocking at joints on exposed faces and watering complete Cu.Mtr 4,512.68
Cable tray
Providing and fixing approved make Ladder type cable tray. Made from M.S sheet. The cable tray should be bended as per IS 2062/1079 shall be fabricated of double bended channel
section longitudinal members with single bended Channel section. Rungs of members welded to the base of tha longitudinal members at 250 mm c/c spacing . as per IS and shall be
103 4.11.9 20.0 coated with hot dip galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification and Mtr 625.19
as per instruction of engineer in charge.
(11) 400 X 100 X 2.0 mm Thick
Providing and fixing approved make Ladder type cable tray. Made from M.S sheet. The cable tray should be bended as per IS 2062/1079 shall be fabricated of double bended channel
section longitudinal members with single bended Channel section. Rungs of members welded to the base of tha longitudinal members at 250 mm c/c spacing . as per IS and shall be
104 4.11.9 30.0 coated with hot dip galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification and Mtr 694.88
as per instruction of engineer in charge.
(13) 600 X 100 X 2.0 mm Thick
Providing and fixing approved make Perforated C type cable tray. Made from CR sheet steel. The cable tray should be single or double bended as per required and as per IS 2062/1079
and shall be coated with hot dip galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as per
Specification and as per instruction of engineer in charge.
(2) 100 X 50 X 1.6 mm Thick
Providing and fixing approved make Perforated C type cable tray. Made from CR sheet steel. The cable tray should be single or double bended as per required and as per IS 2062/1079
and shall be coated with hot dip galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as per
Specification and as per instruction of engineer in charge.
(5) 300 X 50 X 2 mm Thick
Providing and fixing approved make Perforated C type cable tray. Made from CR sheet steel. The cable tray should be single or double bended as per required and as per IS 2062/1079
and shall be coated with hot dip galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as per
Specification and as per instruction of engineer in charge
(6) 450 X 50 X 2 mm Thick
Miscellaneous
108 3-13-1. 3.0 Providing and erecting metallic vitrified danger notice board as per language suggested by engineer incharge for MEDIUM VOLTAGE installation to be erected as per IS-2551. Each 69.69
109 3-13-3 15.0 Providing & erecting Medium Voltage Danger Notice Board sticker as per language suggested by engineer incharge of standard size as per IS-2551 Each 26.26
Double walled corrugated pipes
Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene (conforming to IS 14930 II) with necessary connecting accessories of same material at
110 4-5-8. 250.0 required depth in existing trench for laying of cable. below ground / road surface for enclosing cable Mtr 95.95
C) 90 mm outer dia
Meters & Panel Accessories
Supplying and erecting approved make panel mounting type Digital Voltmeter having 3 digits LED display, 0 to 750 AC Volts range erected on existing panel board with all
connection, wiring etc .with manufacturers calibration certificate.
Supplying and erecting approved make panel mounting type Digital Ammeter having 3 digits LED display, external CT operated, calibrated for 0 to 1000 Amps suitable to operate on
500 Volt AC , erected on existing panel board with all connection, wiring etc .with manufacturers calibration certificate.
Providing & erecting L.T. Current Transformer with bar primary 50/5 to 1000/5 ratio 15 VA burden erected in existing CRCA box duly secured with insulating materials
connected to the meter
115 9-2-9. 24.0 Supplying and erecting approved make set of indicator lamps of LED type lamp, lens cover, Bakelite holder complete erected with necessary connections. Each 43.43
WATER COOLER
Providing & erecting water cooler having storage capacity 150 Ltr. & cooling capacity 150 Ltr.per hour @ an ambient temp of 45˚ C. The outlet temp. of the water should drop by
116 8-13-2. 1.0 15˚C within a hour, The water cooler should be comprising of hermetically sealed compressor, fan motor, condensing unit, water tank surrounded by evaporating, coil, thermostats, Each 55,893.40
relay etc.complete with necessary inlet & outlet connection. The body of water cooler will be made from Stainless Steel.
Supplying and erecting approved make online Un-interruptible Power Supply system comprising flat cum-boost charger with IGBT base rectifier & Inverter & sealed maintenance
free SMF batteries. The charger having operating capacity for input 160-270V AC & inverter having output 230V,50 Hz Ac with 0.8 load power factor with battery, over/under voltage
117 8-15-5. 1.0 output with over load & short circuit protection equipment. The system housed in CRC sheet duly powder coated paint with following power backup.with MS painted batteries stand, Each 12,38,545.83
10% Overload capacity for momentary load.
[L] 40 KVA 3 - phase with 1Hr Backup
Substation - X'mer
Qty. Description of Item Unit Rate Amount
Supply, Unloading, Shifting at site, installation, testing and commissioning of 11 KV Outdoor HT RMU - 11 KV 630 A, 350 MVA 1no. SF6 breaker as incomer & 2 nos. of 11 KV
630 A SF6 breaker outgoing with dual core CT & PT of appropriate rating for metering and protection as per specification and SLD
The breaker shall be Manual cum motorised mechanism with following accessories.
2. Power Factor Meter
3. Double core current transformer cast resin type having ratio 200 to 50/1 core for metering & second core for protection having required class of accuracy.
4.lnstantaneous under voltage Relay & Temperature rise tripping Relay
5. Electrical closing, coil & short trip coil operating on 1200V D.C.
6. Auxiliary relay for anti pumping device.
118 RA-2 1.0 Each 8,42,087.50
7. Three phase Three limb Drawout type feeder connected & output of 200 VA cast resin insulated potential transformer having ratio 12000V / 110V and 200 VA Burdon with
8. Common Alarm bell operating on 110V A.C.
9. Load Manager and KWH Meter.
10. Cable boxes suitable up to 11KV 3 core 240 sq.mm XLPE cable.
11. 230V A.C. to 110V. D.C. power pack for closing & tripping circuit common.
12. Breaker ON-OFF, Auto trip and spring charged indicators.
13. Phase indicating & panel illumination lamps with plug socket.
14. Triple pole IDMTL two over current and one earth fault relay with current setting range 50-200% and 10-40
SITC of 11KV OUTDOOR COMPACT SUB-STATION WITH OIL TYPE TRANSFORMER
A. HT SWITCHGEAR
11 KV HT RING MAIN as per following specification,
1 WAY NON-EXTENSIBLE 11 KV , 21 KA FOR 3 Sec MOTORISED OPERATED 3 NOS 630A VCB SF6 ENCLOSED MOTORISED BREAKER 24V DC FROM BATTERY /
BATTERY CHARGER, SELF POWERED 3 O/C +1E/F RELAY - 2 NOS, CT RATIO -100-50/1-1A, CL -5P10, 2.5VA, CL 1.0, 2.5VA, GAS PRESSURE INDICATOR, LOCAL
REMOTE SWITCH - 3 NOS, BATTERY WITH BATTERY CHARGER (230VAC TO 24V DC) - 1 NO, FEEDER PROTECTION RELAY (50,51,50N,51N,64R,27,59) - 1 NOS,
MASTER TRIP RELAY - 1 NOS
DIGITAL TRAFO CARD FOR BUCHHOLZ, WTI, OTI TRIP - 1 NOS, MFM WITH RS 485 PORT - 3NOS ,DIGITAL VOLTMETER - 1 NO,VOLTAGE TRANSFORMER,
11000/RT3/110/RT3/110/RT3, CORE 1 : CL 1.0, 200VA, CORE 2 : CL 3P, 100VA QTY : 3 NOS, Control Cabelling from Transformer to NCT & vice versa shall be in scope of CSS
119 RA-3 1.0 Each 30,30,000.00
B. OIL TYPE TRANSFORMER
SITC of approved make oil immersed 1000 kva ONAN cooled, double wound, core type indoor copper wound 11KV/ 433V step down transformer of following capacities operating on
3 phase, 50 Hz 4 wire & neutral earthed system continuously rated for a full temperature rise in oil not exceeding 45 Deg.C.at maximum ambient temp. of 50 Deg. C. complete with
necessary radiator first filling of new transformer oil & standard fitting as below complying with IS 1180 (Part 1) : 2014 standards with energy efficiency level 2 Off load tap changing
range steps +2.5% to -5% on H.V for variation should be provided. The H.V. shall be connected Delta & Secondary with star connection. The transformer should have cable-end boxes
on H.T. side suitable for up to 3 core 300 sq.mm. XLPE cable & on L.T. side suitable for bus duct or cables as per requirement complete with test certificates from manufacturers
1. Oil conservator with filling Hole & Cap - One No. ,Thermometer pocket with 6" dial type thermometer switch alarm & trip contacts - Two nos., Silica-gel breather with charge - One
No. 4. Plain oil level gauge - One No., Drain / Sampling / Filter valve - One No., Top Filter Valve - One No., Explosion vent with Diaphragm - One No., Rating & Diagram plate - One
No., Additional neutral bushing for earthing - One No., Bi directional Roller - Four Nos. Earthing terminals - Two Nos. Lifting lugs - Two Nos., Air release plug. - One No., Double
float buchholz relay with Alarm and trip contacts., Control cable as required from Transformer to VCB Panel is to be provided with necessary connection to VCB relays for protection.
Providing and fixing printed instruction chart both in English and Gujarati and duly framed with front glasses, for treatment of person suffering from Electric shock with minimum
50" diagonally size.
121 10-2-2. 2.0 Providing pair of rubber hand gloves suitable for working on 11 KV/22 KV supply. Each 214.12
Supplying rubber matting of following thickness as per IS:15652/IEC
122 10-2-3. 20.0 Sq. mtr. 1,027.17
Supplying stand first AID box with antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-aid) adhesive tape
for medicinal user, Scissors, anti-septic solution (Savlon or similar) etc. (All above contents shall be of standard makes)
Providing and erecting ISI Marked 3core 240 Sq.mm XLPE insulated 11 KV armoured cable Aluminium conductor IS-7098 to be laid on wall with clamps or in provided cable
trench / pipe approved manner as directed.
Supplying and making cable end terminations for the following size of 11 KV grade, XLPE aluminium conductor armored cable including termination kit complete heat shrinkable
125 RA-4 4.0 sleeve etc. Each 12,811.85
3 C x 240 sq.mm 11 KV XLPE cable (Outdoor)
Qty. Description of Item Unit Rate Amount
Supplying and erecting, commissioning and testing of Diesel Generating set confirming to IS: 4722:1968 & BS:5514 having continuous rating, 3 phase, 415 volts, 50 cycles A.C.
supply comprising of a totally enclosed air/water cooled diesel engine with multi-cylinders developing suitable BHP not less than following capacity at 1500 RPM with 10% overload
for one hour in 24 hours with standard accessories like fly wheel, lubricating oil cooler, "A" class governor, heavy duty fuel wheel and lubricating oil filter, oil bath air filler, lubricating
oil pressure gauge, end exhaust manifold, standard set of tools with adjustable spanners, screw drivers, cylinder head to cover, joint cylinder head to exhaust, element lube oil filter, 12 /
24 volts electric starting equipment complete with standard heavy duty battery, dynamo, cut-outs, ammeter, necessary wiring, pressure gauge, starter etc and heavy duty Residential type
exhaust silencer (With DEF System) and vertical hot air duct both logged with asbestos rope, save oil trays, exhaust piping of required length, standard wall/floor mounted fuel with
level indicator and piping and drip proof alternator, self excited, self regulated, screen protected, with excitation system, capable of delivering the rated system output at 415 volts,
phase, 0.8 PF, 50 Hz, 4 wire, running at 1500 RPM, conforming to IS-4722- 1968 with voltage regulation +/- 5% of rated voltage from no load to full load. Both the engine and
alternator fitted on a common fabricated steel base plate with antivibration mounting engine and alternator both connected to each other by flexible flange coupling and with
The alternator & control panel shall be connected with provided suitable capacity armoured cable and complete with Acoustic enclosure (canopy) made out of 16 SWG CRCA Sheet,
sound absorbing material Rockwool of 64 density & 100 mm thick conforming to IS:8183 / PU Foam of 40 Density - at least 40 mm. The resin bonded rockwool covered from inside the
canopy by perforated sheet with 3/4 mm holes, sound level not more than 75 dB at a distance of 1 mtr, as per PVCT norms.DG set should have in built fuel tank capacity of minimum
hrs of continous running capacity on full load . Erection, commissioning and satisfactory testing as per requirement with first filling of fuel (minimum up to the 80% of fuel tank
capacity), oil, etc. with guarantee / Warrantee of complete system for Two years. & with obtaining all necessary certificate from Electrical Inspector. The Capacity and Ratings of DG
sets are as below. (As per new CPCB-IV Emission norms Engine With - Turbo Charger, EGR (Exhaust Gas Recirculation), CRS (Common Rail Fuel System), DOC (Diesel Oxidation
(V) Continuous rating of 500 KVA ,BHP not less than 600 BHP
Providing & erecting approved make AMF control panel suitable for following size of 3 phase, 415 V., 50 cycles, A.C. diesel generating set complete of scope as detailed below:
1) Power module: A pair of electromechanically interlocked contactors (for mains & generator) Overload relay for generator contactor Neutral contactor for mains and generator
Power socket for connections.
2) Control and metering module: Line voltage monitor. Generator voltage monitor Ammeter 3 items attempt start facility. Air circuit breakers/MCB/MCCB of suitable rating for
auto/manual operation. Auto/manual switch. Emergency stop push buttons. Manual start push button. frequency meter. Engine hour meter. Two earthing studs.
3) Protection module: The engine shutdown in the unlikely event of Low lube oil pressure High cylinder head temperature. V belt failure.
4) Indicators with alarm Load on generator.
5) Indicators Load on mains Engine fails to start . Emergency stop battery charger.
The AMF Panel of following capacity
(G) AMF Control Panel for 500 KVA 3 phase DG Set
Design, Supplying, installing, testing of factory fabricated ready made Three phase APFC Panel Cubical Panel fabrication should be type tested as per IEC 61921, 61439:1&2 Capacitor
Duty Contactor for switching as per following Steps Incomer Switch of MCCB type Icu=Ics=50KA at 400/440 Volts, with OC, SC, internal earth fault protection Incomer Switch of
MCCB type Icu=Ics=50KA at 400/440 Volts, with OC, SC, internal earth fault protection,Copper tinned insulated Busbar,Cubical panel should be indoor type with IP 43 and IK
10,Metalized polypropylene film tye3-phase 550Volt Capacitor,De tuning Reactor for each capacitor,Panel having Short Circuit and Overload protection,Each step Capacitor having
suitable MCB with Sc, OL, internal earth fault relay,Each stage having Stage Contactor (Capacitor load rating),PF regulator master controller having suitable steps with LCD display, Rs
485 Communication port, Indication LED Lamps for main incomer and ON-OFF for each capacitor bank,MS Chanel for Floor mounting, Cable entry as per site situation,Cooling fans
(F) 200KVAR
129 3-15-6. 1.0 Providng and erecting Approved make. energy meter 3 phase 4 wire unbalanced load 500 V.50A / 100A complete erected as directed with necessary earth wire. Each 2,611.86
130 3-15-7. 1.0 Providng and erecting Suitable set of CTS for 100A Energy Meter Each 2,126.91
POWER CONNECTION & STATUTORY APPROVALS
(LIAISONING WORK FOR TORRENT POWER/GEB FOR TRANSFORMER/HIGHRISE - 1 NOS. CSS & 1 NOS. DG SETS , HIGHRISE , LIFT)
131 RA-5 1.0 Charges for doing liasioning work for taking power for the premises obtaining the necessary clearances from the Electrical inspector / competent Authorities for the total Electrical Job 1,01,000.00
installation, co-ordinating with various agencies. All necessary drawings, calculations, test certificates, etc. as required by these authorities shall be prepared and furnished by the
contractor. Any modification/rectification as required by these authorities shall be carried out by the Contractor.
LIGHTNING ARRESTER
SITC of Vertical Air Termination Solid aluminium with Base- 10 mm dia and 1000 mm long. Air Termination Base tested for conditioning, Ageing Test & Lightning impulse current
132 10-5-1. 1.0 withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol with MAST 34mm dia 3000 mm long- Cold Each 9,416.23
Galvanized
Qty. Description of Item Unit Rate Amount
SITC of 8 mm dia solid Aluminium Conductor for roof top mesh grid and tested as per IEC 62561- 2 conducted in the Govt. accredited thirty party laboratory to meet the requirement
of IS/IEC 62305 with Required Accessories - Aluminium Holding clamp at every 1 mtr distance, Aluminium/SS cross splicer at every crossing of Alu. conductor, Expansion piece with
133 10-5-2. 30.0 connectors at every 20 mtr distance, Aluminium straight Splicer to connect conductors. All Accessories should be tested as per IEC 62561-1 2018 Cl. 6.3 for conditioning & Ageing Mtr 299.97
Test & 6.4 for Lightning impulse current withstand test: 100 kA of 10/350µs waveform(Ageing & Electrical test ) conducted in a sequence manner & tested in the Govt. accredited
Third party laboratory to meet the requirements of IS/IEC
SITC of 14.2 mm dia 3 mtr long Earth electrode of High tensile steel electrode with 250 micron copper bonding & 1 bag of Carbon fill Based environment friendly backfill tested as per
134 10-5-5. 2.0 IEC 62561-7 in NABL accredited Laboratory and suitable stainless Steel double sided clamp. Eco Friendly rust proof heavy duty weather proof Polyethylene Earth Pit Chamber with Per Set 5,992.33
following dimensions :254 mm dia (top), 330 mm dia (bottom) & 260 mm (height).
(a) General Features & Special Features of the all lift items shall be taken as below.
(b) for Handicap Lifts, Minimum 10 Passengers Lift Capacity shall be considered.same is to be informed to architect /civil authority to keep necessary size of lift well.
(c) The lifts of 15/ 16 and above passenger capacity shall be taken for Hospital Lifts; Where in Description “ Stretcher Lifts” shall be mentioned.
(d) The Rates of the following items are for the lift of Machine room less. For Machine room Lifts, rate for Rs. 1,50,000/- shall be deducted in Total Cost for the Lifts from 4 to 13 Passenger Lift. Rs. 2,00,000/- shall be deducted in Total Cost for the Lifts 15 and
(e) Add Rs. 80,000/- for the DUPLEX control for the lifts up to 10 floors and add Rs. 10,000/- for additional each floor above 10 floors.
(A) GENERAL DESCRIPTION OF LIFTS.
[1] GEAR LESS LIFT DRIVE (MRL) comprising of High Starting torque Lift 3 phase 440 V A. C. Permanent Magnet Synchronous motor of proper rating with high efficiency shall be used.
[3] Car with M S platform with bracings of adequate size and to sustain the impact load cabin + passenger with safety factor of fire for steel and side panels of Stainless steel of sheet of grade 304 duty. Car ceiling will be S.S. finishes with aesthetic appearance with
[4] All landing doors must be fire rated for 2 hour shall be fully automatic centre opening/ telescopic opening made of hairline finish steel grade of 304 with key holes and infrared curtains with Unlocking facility from outside
[10] Spring buffers/PU Buffers shall be provided.
[17] Permanent wiring with necessary safety devices like RCCB in all circuit, Over Voltage Under Voltage protection and THD eliminator in circuit for lift machine room and lift well with proper numbers of light points, with fixtures, exhaust fan and plug points
[20A] As per statutory requirement of Govt. Of Gujarat lift & escalator act 2000, lift agency has to provide
[21] Car Panel Operating Buttons with floor position indicator/buttons must be of Auto Glow type clearly visible when view from inside cabin.
13-1 DESCRIPTION OF LIFT :
26 passengers . Ground plus 4 upper floors with Rated Speed of 1.0 m/sec with micro price/PLC control and ACVVVF. drive
135 13-1-BN 2.0 Each 26,40,302.61
(C) With General PLUS ADDITIONAL SPECIAL FEATURES attached herewith. Prem. Cat.
Supplying & erecting approved make Lift Announcing solid state system in the Passenger/ Stretcher lifts having AC2/ACVV/ACVF drives & automatic doors only. The system
comprising following features & facilities.
(i) Announcing floor message, message to close period.
(ii) Announcing ‘Emergency Message’ when lift is stuck between floors due to power failure or any other reason.
(iii) Instrumental Music between floor announcing.
(iv) Announcement in English / Hindi & Gujarati Languages..
(v) Flexible to accommodate special per-programmed message such as name of the building /office.
(vi)Volume adjustment control
Providing & erecting approved make overload non-start feature & overload warning Indicator system in the lift with making use of sound isolated floating platform & micro switches on
SI frame to get sensation of live load inside lift cage at any given moment, with provides new fixtures of overload warning inside lift cage with new relay in the existing control panel to
activate ‘Overload Non-Start Function with carrying out additional wiring including laying of new travelling cable, include minor civil work & without changing the existing capacity
speed stops, travel & operation of the desired lift
SECTION 13.00 Comprehansive Maintenance for General Electrical and ELV Works
Provide annual maintenance service (including supply of material) and operation for 1 years after handing over of work for electrical and ELV works as per schedule including
138 Gov. Aproved 1 Job 9,28,499.12
necessary materials to be given under warantee free of cost, etc.
1st Year (After DLP Period)
Provide annual maintenance service (including supply of material) and operation for 1 years after handing over of work for electrical and ELV works as per schedule including
139 Gov. Aproved 1 necessary materials to be given under warantee free of cost, etc. Job 9,28,499.12
2nd Year (After DLP Period)
Provide annual maintenance service (including supply of material) and operation for 1 years after handing over of work for electrical and ELV works as per schedule including
140 Gov. Aproved 1 necessary materials to be given under warantee free of cost, etc. Job 9,28,499.12
3rd Year (After DLP Period)
Qty. Description of Item Unit Rate Amount
Supplying skilled labour ITI Electrician for Electrical maintanance work like over had line, street light cable connection wiring faults and repairng works at hopspital/medi. college
Campus with all requiered instruments & tools (taparia or approved make) like tester, dismis, hammer, crimping machine, insulation tape,magger, clip on meter, earth tester, spanner
box, 6 to 8 foot ladder , as work assigned by Engineer In-charge on all working day or as per Instruction given at minimum wage act. payment will be done to all person in presence of Per
141 Gov. Aproved 12 39,612.52
Engineer Incharge. (i-card & uniform must essential) Attendance sheet (software generated) to be submitted for payment. month
1st Year Operation (During DLP Period)
(B) One nos. ITI Electrician per shift (Govt. License Holder) (Two Shift = 8 Hours) (payment to be given as per requirement of man power as per shift)
Supplying skilled labour ITI Electrician for Electrical maintanance work like over had line, street light cable connection wiring faults and repairng works at hopspital/medi. college
Campus with all requiered instruments & tools (taparia or approved make) like tester, dismis, hammer, crimping machine, insulation tape,magger, clip on meter, earth tester, spanner
box, 6 to 8 foot ladder , as work assigned by Engineer In-charge on all working day or as per Instruction given at minimum wage act. payment will be done to all person in presence of Per
142 Gov. Aproved 12 41,593.15
Engineer Incharge. (i-card & uniform must essential) Attendance sheet (software generated) to be submitted for payment. month
2nd Year Operation (During DLP Period)
(B) One nos. ITI Electrician per shift (Govt. License Holder) (Two Shift = 8 Hours) (payment to be given as per requirement of man power as per shift)
Supplying skilled labour ITI Electrician for Electrical maintanance work like over had line, street light cable connection wiring faults and repairng works at hopspital/medi. college
Campus with all requiered instruments & tools (taparia or approved make) like tester, dismis, hammer, crimping machine, insulation tape,magger, clip on meter, earth tester, spanner
box, 6 to 8 foot ladder , as work assigned by Engineer In-charge on all working day or as per Instruction given at minimum wage act. payment will be done to all person in presence of Per
143 Gov. Aproved 12 43,672.81
Engineer Incharge. (i-card & uniform must essential) Attendance sheet (software generated) to be submitted for payment. month
3rd Year Operation (After DLP Period)
(B) One nos. ITI Electrician per shift (Govt. License Holder) (Two Shift = 8 Hours) (payment to be given as per requirement of man power as per shift)
Supplying skilled labour ITI Electrician for Electrical maintanance work like over had line, street light cable connection wiring faults and repairng works at hopspital/medi. college
Campus with all requiered instruments & tools (taparia or approved make) like tester, dismis, hammer, crimping machine, insulation tape,magger, clip on meter, earth tester, spanner
box, 6 to 8 foot ladder , as work assigned by Engineer In-charge on all working day or as per Instruction given at minimum wage act. payment will be done to all person in presence of Per
144 Gov. Aproved 12 45,856.44
Engineer Incharge. (i-card & uniform must essential) Attendance sheet (software generated) to be submitted for payment. month
4th Year Operation (After DLP Period)
(B) One nos. ITI Electrician per shift (Govt. License Holder) (Two Shift = 8 Hours) (payment to be given as per requirement of man power as per shift)
Supplying skilled labour ITI Electrician for Electrical maintanance work like over had line, street light cable connection wiring faults and repairng works at hopspital/medi. college
Campus with all requiered instruments & tools (taparia or approved make) like tester, dismis, hammer, crimping machine, insulation tape,magger, clip on meter, earth tester, spanner
box, 6 to 8 foot ladder , as work assigned by Engineer In-charge on all working day or as per Instruction given at minimum wage act. payment will be done to all person in presence of Per
145 Gov. Aproved 12 48,149.27
Engineer Incharge. (i-card & uniform must essential ) Attendance sheet (software generated) to be submitted for payment . month
5th Year Operation (After DLP Period)
(B) One nos. ITI Electrician per shift (Govt. License Holder) (Two Shift = 8 Hours) ( payment to be given as per requirement of man power as per shift)
Supplying skilled labour ITI Helper for Electrical maintanance work like over had line, street light cable connection wiring faults and repairng works at hopspital/medi. college Campus
with all requiered instruments & tools (taparia or approved make) like tester, dismis, hammer, crimping machine, insulation tape,magger, clip on meter, earth tester, spanner box, 6 to
foot ladder , as work assigned by Engineer In-charge on all working day or as per Instruction given at minimum wage act. payment will be done to all person in presence of Engineer Per
146 Gov. Aproved 12 38,697.11
Incharge. (i-card & uniform must essential ) Attendance sheet (software generated) to be submitted for payment . month
1st Year Operation (During DLP Period)
(B) One nos. ITI Helper per shift (Govt. License Holder) (Two Shift = 8 Hours) (payment to be given as per requirement of man power as per shift)
Supplying skilled labour ITI Helper for Electrical maintanance work like over had line, street light cable connection wiring faults and repairng works at hopspital/medi. college Campus
with all requiered instruments & tools (taparia or approved make) like tester, dismis, hammer, crimping machine, insulation tape,magger, clip on meter, earth tester, spanner box, 6 to
foot ladder , as work assigned by Engineer In-charge on all working day or as per Instruction given at minimum wage act. payment will be done to all person in presence of Engineer Per
147 Gov. Aproved 12 40,631.96
Incharge. (i-card & uniform must essential ) Attendance sheet (software generated) to be submitted for payment. month
2nd Year Operation (During DLP Period)
(B) One nos. ITI Helper per shift (Govt. License Holder) (Two Shift = 8 Hours) (payment to be given as per requirement of man power as per shift)
Supplying skilled labour ITI Helper for Electrical maintanance work like over had line, street light cable connection wiring faults and repairng works at hopspital/medi. college Campus
with all requiered instruments & tools (taparia or approved make) like tester, dismis, hammer, crimping machine, insulation tape,magger, clip on meter, earth tester, spanner box, 6 to
foot ladder , as work assigned by Engineer In-charge on all working day or as per Instruction given at minimum wage act. payment will be done to all person in presence of Engineer Per
148 Gov. Aproved 12 42,663.56
Incharge. (i-card & uniform must essential ) Attendance sheet (software generated) to be submitted for payment . month
3rd Year Operation (After DLP Period)
(B) One nos. ITI Helper per shift (Govt. License Holder) (Two Shift = 8 Hours) (payment to be given as per requirement of man power as per shift)
Qty. Description of Item Unit Rate Amount
Supplying skilled labour ITI Helper for Electrical maintanance work like over had line, street light cable connection wiring faults and repairng works at hopspital/medi. college Campus
with all requiered instruments & tools (taparia or approved make) like tester, dismis, hammer, crimping machine, insulation tape,magger, clip on meter, earth tester, spanner box, 6 to
foot ladder , as work assigned by Engineer In-charge on all working day or as per Instruction given at minimum wage act. payment will be done to all person in presence of Engineer Per
149 Gov. Aproved 12 44,824.28
Incharge. (i-card & uniform must essential ) Attendance sheet (software generated) to be submitted for payment. month
4th Year Operation (After DLP Period)
(B) One nos. ITI Helper per shift (Govt. License Holder) (Two Shift = 8 Hours) (payment to be given as per requirement of man power as per shift)
Supplying skilled labour ITI Helper for Electrical maintanance work like over had line, street light cable connection wiring faults and repairng works at hopspital/medi. college Campus
with all requiered instruments & tools (taparia or approved make) like tester, dismis, hammer, crimping machine, insulation tape,magger, clip on meter, earth tester, spanner box, 6 to
foot ladder , as work assigned by Engineer In-charge on all working day or as per Instruction given at minimum wage act. payment will be done to all person in presence of Engineer Per
150 Gov. Aproved 12 47,036.58
Incharge. (i-card & uniform must essential ) Attendance sheet (software generated) to be submitted for payment. month
5th Year Operation (After DLP Period)
(B) One nos. ITI Helper per shift (Govt. License Holder) (Two Shift = 8 Hours) (payment to be given as per requirement of man power as per shift)
Total Cost of Electrical Work
Construction of Auditorium At TP No 124C, FP No 31 (Social Infrastructure), in Thhakarnagar Ward, North Zone, Ahmedabad.
BOQ of ELV Work
Description of Work Total Qty Unit Rate Total Amount
Description of Work Total Qty Unit Rate Total Amount
SITC of Digital / PCM / TDM EPABX System having SMT design, system with flexible universal slots. Inbuilt Auto attendant facility,
Minimum 15 Nos. conference, Analog extension line, Calling GSM, E&M line, PRI / EI & VOIP program me through Analog telephone
digital key from Ethernet, public address cord, shall have unrestricted simultaneous dialing facility,
QSIG protocol on PRI, 95 / STD / ISD / Local-Locking, Class of Service, Quick Dial-Single Digit dialing of any two external number,
1 E-1 Once only ring device, Boss/Secretary-Do not disturb Facility, Power Down Mode, Hot Line, Hot Outward Dialing, Day Night Mode, 1.00 Nos. 45,398.49
Auto Call Back, Barge-in, Call Pick Up & Call Transfer, Call transfer while Ringing with Voice Guide System, (DISA), Caller ID (CLI),
CLI Base ECF, CLI Base routing Internet Ready Port, External Music Port, Call Budgeting, Call Most Calculation (ASMDR), DID
Direct Inverse Dialing, External Music Input, Fax Homing, Global Directory Printing with following capacities
[A] No of Extension 16, No of Junctions 6, 8 Port IP Resource in-built, 4 Port Web base Video Conferencing, No of expandable ports :
48, Operators Console - 01 Compatible : ISDN
Telephone Distribution
Providing and installing of all conduiting and structured cabling for telephone system including providing and fixing of the following:
1) All necessary specials and fittings
2) Approved cover plates for inspection, junction and outlet boxes.
3) 2 mm thick outlet boxes (MDF) and junction boxes.
4) All fixing accessories such as clips, nails, screws etc.
5) Providing and fixing approved saddles, hooks and grouting the same as required, in the case of all exposed conduit work.
6) Embedding conduits and accessories in wall, floors etc. during construction and / or cutting chases and making good as
necessary in the case of all concealed conduit work.
Supply and installation, testing and commissioning following size KRONE make telephone tag block in lockable 16 gauge sheet steel
enclosure complete as required.
10 pair Krone type tag block
PVC & HDPE Conduits
Supply & laying of 25 mm dia. rigid PVC conduit of 2.0-2.2 mm thick heavy gauge with all accessories.
4 E-4 Supply & laying of 40 mm dia. rigid PVC conduit of 2.1 -2.3 mm thick medium gauge with all accessories. 50.00 Mtr. 67.67
Telephone Point Wiring
Supply and laying of specified make 0.51 mm dia Tinned copper telephone wire of specified make to be done in prelaid PVC pipe of
5 E-5 mm dia/raceway of specified make, but without the cost of pipe or raceway. (the wire is to be drawn from Krone connector of respective 100.00 Mtr. 40.40
area to outlet point)
5 pair telephone wire
6 E-6 10 Pair Telephone Wire 50.00 Mtr. 65.65
7 E-7 Supply, Installation, Testing And Commissioning of Solid Cable Cat 6, 4 pair, UTP. 500.00 Mtr. 47.47
Telephone Outlet Point
SITC OF PowerCat 6 DataGate Jack, 568A/B - Yellow with Dust Cover / Blank/ One Telephone Point to be done with Cat -6
8 E-8 Information outlet Socket, Back Box, Face Plate for all telephone point. Average Length to be considered as 50 Meter. Cable Laying, 10.00 Nos. 160.59
Labling, Ferrule, Testing, Certification to be included in cost. 20 Years of Certification is required. Test reports of Level-4 Scanners only
of make Legrand / Molex/ Systimax / Panduit / Siemon
SITC OF DG+ Jack (Diecast)Cat6A 568A/B, Shtd- Black (Information Outlet for Data) with Faceplate, back box CAT-6A standards.
9 E-9 Cable Laying, Labling, Ferrule, Testing, Certification to be included in cost. 20 Years of Certification is required. Test Reports of Level- 15.00 Nos. 160.59
4 Fluke Scanners Only of make Legrand / Molex/ Systimax / Panduit / Siemon
STIC OF 24 Port Layer 2 Fully Managed Network Switch with 24 10/100/1000Base T Ports and 4 GE SFP Ports. Include Limited
Lifetime Warranty.
11 E-11 Supply, installation, testing and commissioning of 24 Port loaded Patch Panel 4.00 Nos. 4,878.30
12 E-12 Supply, installation, testing and commissioning of Patch Cord-1m 50.00 Nos. 176.75
13 E-13 Supply, Installation, Testing and Commissioning of Equipment rack / Console as per requirement 2.00 Nos. 43,129.02
Description of Work Total Qty Unit Rate Total Amount
Description of Work Total Qty Unit Rate Total Amount
Supply, Installation, Testing & Commissioning of Network TDN IR Mini Dome Camera, 1/2.9" CMOS, 5 MP @ 25fps, Triple stream,
Min. Illumination required 0.25 lux @ color, WDR 120dB, Min. Pixels 2560 x 1920, Shutter Speed 1/30000 - 1/5; Adavance Video
Compression technology such as H.265 / H.264 / MJPEG, 3mm~8mm, MFZ lens, HLC, 3DNR, Minimum Edge Intelligence Video
Analytics: Motion Detection, Camera Tampering, Intrusion/Object enter area; 4 nos Privacy Mask, Smart IR with upto 30m IR distance,
AES-128/256, PCI Data Security Standard compliance, 128GB SD card support, DC12V, PoE (IEEE 802.3af) (Class 2), IP 66, IK10,
Having Operating temp range : –10°C to 50° C. Certifications: ONVIF Profile S, G compliant, UL, CE/EN, FCC Part 15 & RoHS
compliant along with mounting brackets suitable for Cieling / Wall mounting & required accesories as per site requirement.
Supply, Installation, Testing & Commissioning of 5MP IP Network TDN IR Bullet Camera, 1/2.8" CMOS, 5 MP @ 25fps, Triple
stream, Min. Illumination required 0.05 lux @ F1.4 (color), WDR>120dB, Min. Pixels 2560 x 1920, Shutter Speed 1/30000 - 1/30;
Adavance Video Compression technology such as H.265 HEVC / H.264 / MJPEG, Smart Codec, 2.7-13.5 mm 5X motorized focus &
zoom lens, P-IRIS, HLC, 3DNR, Minimum Edge Intelligence Video Analytics: Motion Detection, Video Tampering, Intrusion, Loiter,
Line crossing, Unattended object, Missing object, Face detection; 5 nos Privacy Mask, 4 IR LEDs Smart IR with upto 60m IR distance,
Stream encryption, AES-128/256, PCI Data Security Standard compliance, FIPS Chipset Built-In, 256GB SD card support with SD card
encryption, Dual channel Audio G.711a / G.711 Mu / G.726, Alarm: 2 In/ 1out, In-built Heater; PoE+ (802.3 at) and 12V DC/24V AV;
IP 66 / IP 67 / NEMA 4X, IK10, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S, G compliant, UL, CE
(EN 50130-4 & EN 55032) , FCC Part 15 & RoHS compliant along with mounting Brackets suitable for Pole / Wall mounting &
required accesories.
Supply, Installation, Testing & Commissioning of Network Video Management & Monitoring Software (NVMMS) system with
distributed architecture to collect, manage and present video from all the cameras and supports emerging technologies in the industry,
like 4K resolution, H.265 video compression codec. The NVMMS shall have option to support database redundancy and 1+1 and N+M
NSM failover features for unforeseen/maintenance scenarios for increased system reliability. NVMMS shall support NSM's licenses upto
100 cameras & 3 user clients without any additional version upgrade. The NVMMS should support network joystick controller, GPU
rendering support for H.264 and H.265 decoding , video on demand, Adaptive video throttling, rule engine, operatore role management,
server based Video Motion Detection (VMD), edge storage backfill support, bookmark with manual comment, bookmark based search,
timeline search, Preview search, synchronous playback from all NSMs, monitor wall support, surrounding camera mode, Cybersecured
with features such as Digital Signing, compliance, HTTPS & SSL base, smart web client, secured firewall configuration, password
expiry, non-recoverable password; support ANDROID & iOS phones, seamless integration with intgegrated security platform which
provides HSDK&API for further integration with 3rd party systems. NVMMS shall support iLIDS certified Analytics like Licence plate
recognition and intrusion/LoiteTrace.
Supply, Installation & Commissioning of NVMS workstation/PC with minimum Intel Core i7-6700, 3.4GHz, 8GB RAM, Windows
(64 Bit) OS, DVD R/W, Integrated Intel HD graphics 530 and NVIDIA Quadro NVS 315 1 GB PCIE x 16 LP supporting 4 Monitors.
17 E-17 The NVMMS shall be complete system for satisfactory surveillance operations with all necessary softwares, licenses, required PC 3.00 Nos. 2,15,754.18
Hardware, Storage, accessories etc., civil, electrical works & peripheral items, as required as per specification in Annexure A at site of
work inline with the Engineer in Charge instructions..
18 E-18 Supply, Installation, Testing And Commissioning of 55" HD Monitor for viewing the cameras 2.00 Nos. 78,654.76
19 E-19 Supply, Installation, Testing and Commissioning of Equipment rack / Console as per requirement 3.00 Nos. 43,035.09
SITC of HP 2530-48G-PoE+ Switch, 48 10/100/1000 PoE+ ports, 4 SFP ports 382W PoE+ (J9772A) + 1 number of SFP Module of HP
Make X121 1G SFP LC SX Transceiver, MM, 850nm, 550m (J4858C)
Supply, Installation, Testing And Commissioning of Layer 2 Managed Gigabit POE switch with 24 # 10/100/1000BaseT ports and 2 #
Gigabit Combo ports(RJ45/SFP), 2 # Gigabit SFP Port.
22 E-22 Supply, installation, testing and commissioning of 24 Port loaded Patch Panel 4.00 Nos. 4,925.77
23 E-23 Supply, installation, testing and commissioning of Patch Cord-1m 80.00 Nos. 176.75
Supply and laying of PowerCat 6A U/FTP CM 4 Pair Cable, LSZH Sheath - Violet of specified make to be done in prelaid PVC pipe of
24 E-24 25 mm dia / raceway of specified make, but without the cost of raceway or pipe ( the wire is to be drawn from HUB \ Switch of 6,500.00 Mtr. 47.47
respective area to outlet point ) with the cost of the crimping with material of make Legrand / Molex/ Systimax / Panduit / Siemon
25 E-25 Supply and laying of Cat-6 STP LSZH UV outdoor cable in PVC conduit with termination as per TIA 200.00 Mtr. 58.58
26 E-26 SITC of 10 Core Single Mode Fibre Optic Cable 1,500.00 Mtr. 64.64
Description of Work Total Qty Unit Rate Total Amount
Description of Work Total Qty Unit Rate Total Amount
Fire Detection System
Supply, Installation, Testing And Commissioning of UL864, 10th Edition Microprocessor based 10 loop, True Peer-to-Peer Networkable
Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 event plus 1000 alarm log history events,
QWERTY keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in
each loop. Each loop shall have a capacity of minimum 250 analog addressable devices. The panel shall work in degrade mode in case of
27 E-27 CPU failure, Products not having this feature may offer Redundant CPU. Four access levels, flash EPROM, 240 volts AC power supply, 1.00 Nos. 6,09,787.50
automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition. The
panel shall be compatible with Integrated 8 channel Digital Voice Evacuation System Controller capable of broadcasting Evacuation
Messages on same peer-to-peer Network and 2 ways Communication Fire Fighters System capable of supervising all the speaker circuits
with adequate zone control and accessories. Failure of Fire Panel CPU shall not result in failure of DVC operation. The Fire Fighters
Telephone System shall be capable of having minimum 30 Telephones in conference in multiple FFT Risers.
Supplying, Installation, Testing and Commissioning of Network Repeater Panel with minimum 10" Color Touch Screen display with
QWERTY Keypad, mapping minimum 2,00,000 points on network. The NRP shall act as an independent node communicating on the
peer to peer network and shall not be dependant on the Fire Panel CPU for operation. Failure of Fire Panel CPU shall not result in failure
of NRP operation.
Supply, Installation, Testing And Commissioning of UL Listed Graphics User Interface for Monitoring & Control of complete Fire,
Voice Evacuation & Telephone Talkback System. The GUI based main network software shall network with other panels on True Peer-
to-Peer network. It shall be capable of graphically representing each facility being monitored with floor plans and icons depicting the
actual locations of the various systems, and / or sensors’ locations. It shall have the facility to change the sensitivity of any detector. The
29 E-29 software shall be capable of monitoring 200 Nodes with 100 Mbps Transmission rate on Fibre Optics Network and 12 Mbps 1.00 Nos. 3,48,450.00
Transmission on cable and 2,50,000 network points. The software shall be capable to Monitor & Control all the Digital Voice
Evactuation as well as 2 way communication from main control room using voice signals over Fire Network along with the Fire detection
signal. The Graphic workstation shall act as an independent node communicating on the peer to peer network and shall not be dependant
on the Fire Panel CPU for operation. Failure of Fire Panel CPU shall not result in failure of GUI.
Supply, Installation, Testing And Commissioning of Automatic printer capable for interface with NCS and provided with RS 232/RS
30 E-30 protocol port. It shall be standard cartage with 80 characters per line as per all requirements of technical specifications & contracts 2.00 Nos. 19,745.50
Supply, Installation, Testing And Commissioning of UL268, 7th Edition Addressable Multi-criteria Photo-Thermal Detector with
sensitivity range of 0.5 to 4.0% obs/ft.The intelligent multi criteria detection device shall include the ability to combine the signal of the
thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include
the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and
smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. The detector shall have twin bi-
colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches.
Supply, Installation, Testing And Commissioning of UL Listed Addressable Rate of Rise Heat Detector rated at 8.3 deg C/min. The
detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches.
Supply, Installation, Testing And Commissioning of UL listed Addressable Manual Call Point (Pull down / Break Glass Type). The
device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device.
Supply, Installation, Testing And Commissioning of UL Listed Sounder cum Strobe rated at 80 dBA @ 3m for Audible annunciation and
115cd flashintg at 1 Hz for visual indication. UL Listed
Supply, Installation, Testing And Commissioning of Addressable Control Module for Sounders / Strobes / Sounder cum Strobes. The
control module shall provide supervised NAC output rated at 24v DC, 2A. The device shall have an LED which shall blink in normal
state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches.
Module shall be supplied with mounting plate from OEM for ease of installation & maintenance.
SITC of Optical Beam Detector with transmitter and receiver set of UL Listed. The detector shall have Minimum 90 m range, Automatic
36 E-36 compensation, Maximum coverage 1500m2, Automatic Signal strength adjustment, Emitter unit can be powered directly from zone (or 8.00 Nos. 1,07,262.00
loop), Features a Latching or Non- Latching fault relay, Full line continuity options
Supply, Installation, Testing And Commissioning of UL Listed Isolator Module for Isolating short / dewired / loose circuits with
automatic resetting arrangement. Isolator Base can also be proposed, however in that case needs to be considered with each detector &
module. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the
device. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance.
38 E-38 Supply, installation, testing & Commissioning of Battery pack suitable for back up of 4 hours with charger in case of Alarm condition. 2.00 Nos. 37,168.00
39 E-39 Supply, installation, testing & Commissioning of response indicator 400.00 Nos. 523.18
40 E-40 Supply, installation, testing & Commissioning Fire Exit Signage boards with 3hrs battery backup 26.00 Nos. 6,388.25
41 E-41 Supply & laying of 2 Core X 1.5 sq.mm. FRLS Armoured PVC Insulated copper cable 5,500.00 Mtr. 133.32
Description of Work Total Qty Unit Rate Total Amount
Description of Work Total Qty Unit Rate Total Amount
42 E-42 Supply & laying of 4 Core X 1.5 sq.mm. FRLS Armoured PVC Insulated copper cable 150.00 Mtr. 203.01
Providing and fixing approved make Perforated C type cable tray. Made from CR sheet steel. The cable tray should be single or double
bended as per required and as per IS 2062/1079 and shall be coated with hot dip galvanizing as per IS 2629/4759. with coupler plate /
43 E-43 Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification and as per instruction of 500.00 Mtr. 159.58
engineer in charge..
(2) 100 X 50 X 1.6 mm Thick
44 E-44 (5) 300 X 50 X 2 mm Thick 150.00 Mtr. 291.89
45 E-45 (6) 450 X 50 X 2 mm Thick 50.00 Mtr. 549.44
46 E-46 (7) 600 X 50 X 2 mm Thick 30.00 Mtr. 823.15
Fabrication
Supplying , fabricating and installation of various sizes MS race way / junction boxes/clamps/hangers for Cable Tray, Light Fixture made
out of specified size sheet/Angle/Flat/rod/ channel etc as per design with all necessary accessories like bend, junction boxes, coupler,
47 E-47 Anchor fastener, Bolt Nuts, etc.. & work from MS structure for other work with anchor fastener of Hilti make and necessary hardware 3,750.00 Kg 77.77
with necessary welding has to be done to complete the job from ISA / ISMC / PLATE. The job also includes to paint the structure with
two coats of red oxide and two coats color of enamel paint as approved and recommended by consultant. Complete in all respect to be
installed at any height with all necessary arrangements. Contractor has to complete the work up to satisfaction of Consultant
Total Cost of Electrical work with 3 Year O & M
Construction of Auditorium At TP No 124C, FP No 31 (Social Infrastructure), in Thhakarnagar Ward, North Zone, Ahmedabad.
BOQ of Heat, Ventilation and Air Conditioning System
Sr. No. Description Unit Total Qty Rate Amount
1 WATER COOLED SCREW CHILLER WITH VFD.
Supplying, installing, testing and commissioning of multiple compressor ARI Certified SCREW
WATER CHILLING UNITS each complete with 125 TR capacity screw compressors, motor, starter
panel machine mounted, water cooled condenser, insulated chiller, flow switch at chiller and condenser,
vibration isolators, integral refrigerant piping and wiring, grooved couplings for condenser and cooler
water in/out connections, complete charge of refrigerant and oil, accessories as required and called for,
automatic and safety controls mounted in central micro-processor based console panel and all mounted on
a steel frame complete as per specifications including first charge of referigerant and oil. Motor shall be
suitable for 415±10% 50 cycles. 3 phase AC supply.
Cooling Capacity : 125 TR (2 Working + 1 Standby)
Refrigerant: R134a
Chilled Water Temp. (ent.) : 12 deg. C
Chilled Water Temp. (leav.) : 7 deg. C
Condenser water entering temp.:32 ºC
Condenser water leaving Temp.:36 ºC
Chilled Water Flow : 335 USGPM
Cooling water Flow: 500 USGPM
Fouling factor (Evaporator) : 0.00025 (British Units)
Fouling factor (Condenser) : 0.0001 (British Units)
Note:- Vendor has to include the following while quoting the rates for the above chillers.
a.) BMS integration controller with Open Protocol
c.) Tap/Junction box as isolator suitable for Aluminium Cabling Termination
d.) Chiller inlet / outlet connection & condenser inlet / out let piping connection to be provided with
Victaulic Coupling.
e.) Chiller design, construction, leak testing, and installation shall comply with ANSI/ASHRAE
f.) Chiller to meet minimum Energy Efficiency Ratio (EER) as specified in ASHRAE 90.1, ECBC
latest edition
g.) Chillers shall be rated in accordance with AHRI 550/
h.) Chiller should have Remote Monitoring Facility for live data record & review
i.) Performance Parameters between 25% - 100% loading as per AHRI.
j. ) The offered product shall be AHRI certified and model should appear on AHRI directory.
Sr. No. Description Unit Total Qty Rate Amount
Supply, installation, testing and commissioning of Chiller plant Manager to control and monitor all the
auxiliary equipment in the plant room and to provide output in Bacnet over IP.The cost to be inclusive of
supplying & installing all necessary indigenous accessories as required to complete the installation.
Following equipment’s shall be controlled by plant manager. As per drawings and design supplied by
architect and instruction given by authority and E.I.C.
Water cooled Screw chillers with VFD - (2W +1 Stand-by) nos
Primary chilled water pumps - (2W + 1 Stand-by) nos
Condenser water pumps - (2W + 1 Stand-by) nos
Secondary Chilled water pumps (2W + 1 Stand-by) nos
Cooling towers - (2W + 1 Stand-by) nos
Motorised Valves - (2W + 1 Stand-by) nos
Auto Tube Cleaning-3Nos
Pressurization Unit-1 nos
Water level switches in cooling towers
RO unit & pump unit.
The chiller plant manager shall have features like chiller scheduling, chiller sequencing, chiller -cooling
tower power optimization, pump pressure optimization etc. Required DDC for automatic operation of plant
room equipment’s as listed above shall be included along with control and power cabling.
2 SITC of PUMPS
2.1 PRIMARY CHILLED WATER PUMPS.
SITC of End Suction type pumps. The pumps shall have bronze impeller, SS 316 Gland Plate, shaft,
wear rings, seals, bearings. The pump shall have flexible type couplings. Motor shall be TEFC IP55 Sq
Cage, , IE-2 type, suitable for 415 + 10% volts, 50 Hz, 3-phase AC power supply. refer technical
specifications.
The pump shall be mounted on common base frame. The maximum permissible sound level of the pump
shall not exceed 85dbA measured at 1m from pump surface. The pump shall be supplied with necessary
vibration isolators with floating frame. (2W + 1SB)
Water Qty : 340 USGPM Nos. 3.00 1,41,400.00
Head : 18 Mtrs
Impeller : Bronze
Speed : NOT MORE THAN 1450 RPM
Seal : Mechanical
Minimum Efficinecy not less than 75%
2.2 SECONDRY CHILLED WATER PUMPS with 3 nos VFD panel and VSPS.
SITC of End Suction pumps. The pumps shall have bronze impeller, SS 316 Gland Plate, shaft, wear
rings, seals, bearings. The pump shall have flexible type couplings. Motor shall be TEFC IP55 Sq Cage,
IE-2 type, suitable for 415 + 10% volts, 50 Hz, 3-phase AC power supply.
The motors of secondary chilled water pumps shall be suitable for operation on variable frequency drive
and of Multiple pump logic controller with Suitable VFDs and DPT with required control cabling.
The pump shall be mounted on common base frame. The maximum permissible sound level of the pump
shall not exceed 85dbA measured at 1m from pump surface. The pump shall be supplied with necessary
vibration isolators with floating frame. (2W + 1SB) refer technical specifications.
Water Qty : 340 USGPM Nos. 3.00 4,14,100.00
Static Head : 40 Mtrs
Impeller : Bronze
Speed : NOT MORE THAN 1450 RPM
Seal : Mechanical
Minimum Efficinecy not less than 75%
2.3 CONDENSER WATER PUMPS.
Sr. No. Description Unit Total Qty Rate Amount
SITC of End Suction type pumps. The pumps shall have bronze impeller, SS 316 Gland Plate, shaft,
wear rings, seals, bearings. The pump shall have flexible type couplings. Motor shall be TEFC IP55 Sq
Cage, , IE-2 type, suitable for 415 + 10% volts, 50 Hz, 3-phase AC power supply.
The pump shall be mounted on common base frame. The maximum permissible sound level of the pump
shall not exceed 85dbA measured at 1m from pump surface. The pump shall be supplied with necessary Nos. 3.00 2,67,650.00
vibration isolators with floating frame. (2W + 1SB). refer technical specifications.
Water Qty : 500 USGPM
Head : 24 Mtrs
Impeller : Bronze
Speed : NOT MORE THAN 1450 RPM
Seal : Mechanical
Minimum Efficinecy not less than 75%
SITC of Auto tube cleaning system (ATCS) for Condenser Water for Three numbers of Chillers
with all necessory items including valves,& all accesories and panels etc.
3 SITC of CTI CERTIFIED FRP INDUCED DRAFT COUNTER FLOW COOLING TOWERS
SITC of FRP Induced draft counter flow Square / Rectangular type cooling tower; Tower shall be MS
HDG Frame work, Access ladder with Maintenance Platform; FRP Casing and Basin with makeup
including Float valve, Inlet, Outlet,drain, make up, quick fill, equalizer connection, Virgin PVC fills,
Distribution system with PP / ABS Nozzles, Axial Flow Direct/Belt drive Fan with Hollow FRP Blades, Nos. 3.00 4,84,800.00
air inlet drift eliminators & MS HDG Hub driven by IP55 TEFC vertical flanged mounted IE-3 motor
suitable for 415±10% V, 50 Hz, 3 phase supply; power / control wiring, earthing, etc. as per tender
specification.
(2 Working + 1 Standby)
Cooling tower shall be suitable for heat rejection capacity of 654520 kCal/Hr at Ahmedabad
conditions.
Design Ambient Wet Bulb Temp. : 28.3 °C
Entering water temp : 36 deg C
Leaving water temp : 32 deg C
No of cells in each cooling tower :
Total flow rate/C.T. : 500 USGPM
Supply, installation, testing & commissioning of centrifugal type air separator shall have inlet and outlet
4 connections . The unit shall have internal stainless steel air collector tube and perforation. The unit shall be
of suitable flow rating for chillers. Complete as per specifications, technical data sheets and drawings etc,.
a 150 mm dia connection. No 1.00 2,77,750.00
SITC of Closed cell pressurized expansion tank. The body shall be mild steel constructed in accordance
with section VIII of the ASME boiler & pressure vessel code. The insulation shall be Closed cell
5 elastomeric with UV treatment & 26G Aluminium cladding with replaceable EPDM / heavy duty butyl
rubber bladder, mounting stand with all necessary system connection & charging valve connection to
facilitate on site charging along with all necessary valves & fittings.
a Capacity- 500 litres No 1.00 2,02,000.00
SITC of Pressurisation System (fully Automatic) 1W+1S with pressure switch & control panel
completely assembled on skid with valve & manifolds 9 USGPM flow rate @ 45M head
7 SITC of CHILLED WATER TYPE INDOOR UNITS
Sr. No. Description Unit Total Qty Rate Amount
Floor Standing Double Skin Air Handling Units with 43mm thk. PUF insulated Panels with with twin
blower & twin motor with Fan section with dynamically balanced direct-driven Plug type backward SA
fans & VFD competible TEFC squirrel cage induction drive motors of IE-3.
• Coil sections with 6-R chilled water type cooling coil (face velocity not over 500 FPM for Dehumidified
tonnage capacity. Coil shall be intertwined type, i.e. circuiting should be done to provide flow through the
entire coil face.
7.1 • Filter sections with 10-Micron Pre–Filters. All filters should be washable-type.
• AHU-mounted opposed blade aerofoil design SA & FA dampers. Not to be measured separately
• 50mm puff insulation Sandwich insulated SS drain tray, mixing chambers for return air/fresh air,
adequate no. of access doors & blank sections, flexible connection at fan connection, spring type vibration
isolators for fan + motor assembly, internal coving, thermal break etc.
• AHU mounted UVGI system with 253.7 NM wave length & Hour meter for maintaining Indoor Air
Quality. The system must include UV modules with dish antenna shaped parabolic reflectors to ensure that
no stray UV-C radiation is leaked.
a 80.0 TR / 32000 CFM / TSP : 50mm for Auditorium Hall Nos. 2.00 14,78,640.00
7.2 4 WAY CASSETTE UNIT.
Supply, Installation, Testing and Commissioning of Ceiling Suspended Chilled Water Cassettes,
EUROVENT Certified, complete with multi row chilled water coil, minimum 3 speed high efficiency fan
motor, aluminium fins with corrossion resistant coating blue or golden, circular all direction throw type
decorative grill, quiet high efficiency centrifugal fan, easily cleanable synthetic filter with minimum
micron mesh, inbuilt high lift condensate water pump fitted with an EPF drain pan, GI casing body
designed to avoid vibration and condensation, provision for fresh air intake. Units shall be accessorised
with a set of ball valves with strainer at inlet, 2 way valve, air purge valve & pressure independent
balancing & control valve duly insulated with PUF insulation and along with inerconnecting
cabling. Pressure Independent Control cum Balancing valve PN25 rating with minimum IP54 modulating
24V actuator with 0-10VDC control, internally wired to the Cassette for feedback and control, cordless
remote with digital display, hanging rods and accessories. The unit shall be suitable for operation with
230V/ 50 Hz/ 1 phase power supply with necesary cabling and controls. The unit shall have provision for
complete control and monitoring over BMS using Modbus/ Bacnet protocol, additional items and
controllers if required shall also be provided. The units shall be internally pre-fitted with a UVGI system
for IAQ improvent with quartz glass UV lamps, suitable for 253.7 nm wavelength, with all its components,
frame, electronic ballast built-in, adequately positoned to prevent exposure during operation.
a 4.0 TR/ 1400 CFM Nos 4.00 80,800.00
b 2.5 TR/ 875 CFM Nos 6.00 72,720.00
c 2.0 TR/ 700 CFM Nos 7.00 65,650.00
d 1.5 TR/ 664 CFM Nos 4.00 55,550.00
e 1.0 TR/ 448 CFM Nos 2.00 48,480.00
7.3 HIGH STATIC DUCT FAN COIL UNIT ( FCU )
Sr. No. Description Unit Total Qty Rate Amount
Supply, installation, testing and commissioning of ceiling concealed type High Static Duct type Fan Coil
Units, Eurovent Certified, single skin, draw through type with minimum 3 speed fan motor, minimum
row chilled water coil, with Al fins with corrossion resistant coating blue or gold, metallic centrifugal
blower, washable filter minimum 20 micron, insulated enclosed double skin drain tray, hanging rods and
accessories, copper piping connections, etc. of the following capacities. Starter panel with necessary
controls, incoming cable from starter panel to unit, connected with Pressure Independent Control cum
Balancing Valve DN25, with minimum 24V Modulating Actuators IP54 with 0-10VDC control, Digital
Thermostat with Modbus connectivity, Fire retardant canvass connections with GI powdercoated finish
angle flanges on both sides, etc. Additional auxillary tray should accommodate drain valve,2 way valve,
air purge valve & pressure independent balancing & control valve duly insulated with PUF
insulation and along with inerconnecting cabling, & inbuilt drain pump. all valves as per the
specifications and approved drawings. The external static pressure shall be as per specifictions below. The
units shall be internally pre-fitted with a UVGI system for IAQ improvent with quartz glass UV lamps,
suitable for 253.7 nm wavelength, with all its components, frame, electronic ballast built-in, adequately
positoned to prevent exposure during operation.
a 9.4 TR / 3760 CFM / 5mm ESP Nos 3.00 88,768.90
b 11.5TR / 4600 CFM/ 10mm ESP Nos 2.00 95,950.00
SITC of of Advanced Oxidation Pentplasma (AOP) cells comprising of UVC lamp 254 NM on NANO
metallic compound target Alumninum matrix cell duly enclosed by a poly casing tube, with the capability
to produce plasma Hydroxyl oxidizers along with anti microbial coating (EPA Approved). The unit shall
have inbuilt multipin ion generator (+-10^6) pins along with ultrasonic radio frequency waves for pest
repellancy. The UV-C lamp will be a low-pressure mercury type and of such intensity as to provide
minimum performance as listed below. The UV-C lamp will produce only Germicidal UV (by definition
this means 99.99% UV-C energy).The cell will have built in LED indication system stating the operation
7.4 of the 3 technologies the UV lamp, ionizer and pest repellant. The power / control cabling between the
Pentagon units and the power source / controls shall be included in the cost .The system shall be capable of
reducing microbial bacteria, virus and spores , VoC’, odors and particulates matter. The equipment shall
conform to CE and ROHS. Standards certifications shall be submitted along with the technical submital.
the equipment is to be installed. The wattage shall not be less than mentioned.Unit mounted supply air
plenun / duct. The AOP/ Pentagon Cells Should be complete with Transformers, control cabling and Plug
Top & necessary power cable. Vendor to comply all Tender Specifications.
a 32000 cfm for AHU. Nos. 2.00 1,01,000.00
7.5 SITC of Canvass connection as per technical specifications. Nos. 7.00 1,818.00
7.6 Remote control
a Corded remote controllers Nos. 2.00 2,525.00
b Cordless remote controllers Nos. 20.00 3,030.00
8 SITC of CHILLED WATER PIPING
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water
piping inside the building (with necessary clamps, vibration isolators and fittings but excluding
valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of
minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean
temperature class 'O' insulation applied by suitable adhesive complete including repairing of
8.1 damage to building etc. as per specifications and as required complete in all respect.
Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above
150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S.
Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and
a (F) 150mm dia. (32 mm thick insulation) Rmt. 108.00 4,239.98
b (G) 125mm dia.(32 mm thick insulation) Rmt. 18.00 3,849.11
Sr. No. Description Unit Total Qty Rate Amount
c (H) 100mm dia. (32 mm thick insulation) Rmt. 85.00 3,189.58
d (I) 80mm dia.(32 mm thick insulation) Rmt. 82.00 2,532.07
e (J) 65mm dia(32 mm thick insulation) Rmt. 107.00 2,173.52
f (K) 50mm dia(32 mm thick insulation) Rmt. 52.00 1,957.38
g (L) 40mm dia. (32 mm thick insulation) Rmt. 60.00 1,732.15
h (M) 32 mm dia(19 mm thick insulation) Rmt. 40.00 1,537.22
i (N) 25 mm dia(19 mm thick insulation) Rmt. 52.00 1,331.18
PN 16 rated Valves and Strainers complete with companion flanges, nuts, bolts, gaskets, supports
8.3 etc. duly Insulated with Applicable thickness as per Pipe sizeand covered with 7 mil Cloth coated
with anti UV paint and coated with Anti Rodant repellent
A SITC Butterfly valves with actuator (motorised) PN 16 as per specifications.
a 125 mm Dia. Nos. 3.00 45,450.00
Providing and erecting BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal &
O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified
a (B) 150mm dia. Nos. 3.00 8,241.60
b (C.) 125mm dia. Nos. 16.00 7,327.55
c (D) 100mm dia. Nos. 6.00 6,412.49
Providing and erecting Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer
for chilled / hot water circulation including insulation as specified.
a (C.) 125mm dia. Nos. 6.00 17,402.30
b (D) 100 mm dia Nos. 2.00 12,283.62
Providing and erecting NON - RETURN VALVE with duel plate of C I body SS plates
D vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation
including insulation as specified.
a (C.) 125mm dia. Nos. 6.00 9,211.20
E SITC of Expansion Bellows
a 125 mm Dia. Nos. 18.00 11,615.00
F SITC of Forged Brass Ball Valves.
a Size - 50 NB Nos. 15.00 4,545.00
b Size - 25 NB (For Purge or Drain) Nos. 27.00 2,020.00
G SITC of Auto Airvent with 15mm Ball Valve. Nos. 4.00 1,515.00
Providing and fixing in position the industrial type pressure gauges with gun metal / brass
valves complete as required
I Providing & fixing in position the mercury in glass industrial type thermometers. Nos. 18.00 1,132.21
SITC of PVC Drain Piping Insulated with 9mm thick Open cell Elastomeric Rubber covered with
mil Glass cloth and 3 Coats of anti UV Coating complete with Anti rodent repellent.
a 40 mm Dia. Rmt. 100.00 404.00
b 32 mm Dia. Rmt. 100.00 371.68
c 25 mm Dia. Rmt. 80.00 294.92
Providing and erecting BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I
K body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation &
PN 16 pressure rating for chilled / hot water circulation as specified.
a (C.) 125mm dia. Nos. 3.00 24,017.80
Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure
independent type dynamic balancing valve with integrated 2 way modulating control valve in a single
body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall
provide similar transduced feedback output to control system. Maximum close off pressure shall not be less
than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of
Bar minimum.
Sr. No. Description Unit Total Qty Rate Amount
a (C.) 100mm dia. Nos. 2.00 1,38,744.71
SITC of Insulation of Pumps & Air Separator with 50mm thick Open cell Elastomeric Rubber
9 covered with 7 mil Glass cloth and 3 Coats of anti UV Coating complete with Anti rodent repellent Nos. 3.00 12,625.00
as per technical specifications.
10 CONDENSER WATER PIPING
Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS 'C'
class along with necessary clamps, vibration isolators and fittings such as bends,tees etc.but excluding
valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground
10.1 excavation and refilling etc. as per specification and as required complete in all respect.
Note:- The Pipes size 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm
shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for
pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
a (C.) 200mm dia. Rmt. 75.00 5,174.23
b (D) 150mm dia. Rmt. 22.00 3,570.35
SITC of PN16 rated Valves and Strainers complete with companion flanges, nuts, bolts, gaskets,
supports etc.
A SITC Butterfly valves with actuator
a 150 mm Dia. Nos. 3.00 82,820.00
SITC of Butterfly Valves (Lever Operated) providing and erecting BUTTERFLY VALVE
B (MANUAL) with C I body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified
without insulation.
b (A) 200mm dia. Nos. 9.00 14,769.23
c (B) 150mm dia. Nos. 15.00 6,979.10
d (D) 100mm dia. Nos. 6.00 5,262.10
Providing and erecting Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer
for chilled / hot water circulation including insulation as specified.
a Size – 150 NB Nos. 3.00 18,371.90
SITC of POT type Strainer. The strainer shall be single or double type screwed thread for bores of
D up to 50 mm and flanged for bores of 65 mm above. Strainers of up to 50 mm shall be gun metal or
a Size – 200 NB for main Header Nos. 1.00 60,600.00
Providing and erecting NON - RETURN VALVE with duel plate of C I body SS plates
E vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation
including insulation as specified.
a (B) 150mm dia. Rmt. 3.00 9,167.77
F SITC of Expansion Bellows
a 150 mm Dia. Nos. 12.00 13,130.00
G SITC of Forged Brass Ball Valves
a Size - 50 NB (for drain) Nos. 14.00 4,545.00
H SITC of Auto Airvent with 15mm Ball Valve Nos. 4.00 2,020.00
Providing and erecting BALANCING VALVE WITH BUILT IN MEASURING FACILITY with
I C I body flanged construction with EPDM coated disc with long pitch with protected out pipe
insulation & PN 16 pressure rating for chilled / hot water circulation as specified.
b 150 mm Dia. Rmt. 6.00 31,481.70
FRP Coating for exposed condenser water piping with 300 GSM as per enclosed techincal
J Sq.Mtr 80.00 1,752.35
specifications..
11 SITC of Factory Fabricated Ducts as per "SMACNA" Standards
Sr. No. Description Unit Total Qty Rate Amount
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal
rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes,
hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete
as required.
b (A) Thickness 0.63 mm sheet (22 Gauge) Sq. Mtr. 860.00 1,308.96
b (B) Thickness 0.80 mm sheet (20 Gauge) Sq. Mtr. 615.00 1,519.04
c (C.) Thickness 1.00 mm sheet (18 Gauge) Sq. Mtr. 578.00 1,679.63
Supply, installation, balancing and commissioning of site fabricated GSS sheet metal rectangular/round
ducting complete with RTV sealant & neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers,
supports etc. as per approved drawings and specifications of following sheet thickness complete as
a (A) Thickness 0.63 mm sheet (22 Gauge) Sq. Mtr. 30.00 1,257.45
b (B) Thickness 0.80 mm sheet (20 Gauge) Sq. Mtr. 30.00 1,467.53
c (C.) Thickness 1.00 mm sheet (18 Gauge) Sq. Mtr. 30.00 1,885.67
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed
cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile
rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape
insulation complete as per specifications and as required.
a (A) 19mm Sq. Mtr. 1228.00 877.69
b (B) 25mm Sq. Mtr. 960.00 1,102.92
Supplying, fixing testing commissioning of supply air diffuser of powder coated aluminium with
11.5 aluminium volume control dampers with anti smudge ring & removable core and size & shape as per site Sq. Mtr. 19.00 13,688.53
requirement and approved design.
Supplying, fixing testing commissioning of Return air diffuser of powder coated aluminium without
11.6 volume control dampers with anti smudge ring & removable core and size & shape as per site Sq. Mtr. 17.00 9,394.01
requirement and approved design..
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without
11.7 volume control dampers complete as per specifications and size & shape as per site requirement and Sq. Mtr. 1.20 7,073.03
approved design.
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air
path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring
11.8 return so as to close the damper in the event of power failure automatically and open the same in case of
power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The
damper shall also be closed in the event of fire signal complete as required and as per specifications.
a Fire damper Sq.Mtr 5.00 12,024.05
b Actuater Nos. 2.00 11,264.53
24V Actuator for Motorised Duct dampers with Control panel and required Control Cabling as per
specifications.
11.10 Supplying, fixing testing commissioning of Non return damper with all accessories Sq.Mtr 16.00 4,040.00
Providing and fixing acoustic Insulation of open cell nitrile rubber sheet having density of 140-180 kg/m3
and recommanded thickness of 15 mm. NRC (Noise Reduction Coefficient) value of Insulation material
shall be 0.75 in accordance to IS:8225/ISO:354/ASTM 423C. Thermal Resistance, R- value shall be
⁰F ft2 hr/BTU. It shall be fixed inside of the duct with the help of adhesive as per the specifications given.
a 15 mm Thick Sq. Mtr. 105.00 505.00
13 SITC of MCC FOR VFD DRIVEN AHU WITH TWIN MOTOR.
Supply installation, testing and commissioning of the following cubicle type, dead front, sheet steel, wall
A mounted control panels including anchoring into the wall, wiring, incoming, earthing & terminating into
MCCB in each panel.
Sr. No. Description Unit Total Qty Rate Amount
All internal wiring power cabling and copper earthing of air handling unit motors from the panel shall be
BAS. All starters shall be provided with potential free Contact for Connections to Building Automation
The panel shall include the following components and accessories.
Suitable rating Incoming MCCB for fan motors as per the ratings given below, MCCB shall be suitable for
motor duty and able to withstand fault level of 20 KA.
VFD starter as outgoing for each fan motor as per KW ratings
Terminal block for power distribution.
Contactor, over load relay with built in single phasing protection.
Phase indicating lights and indicating light for ON status.
Time delay relay for delayed automatic restart of air handling unit motor.
Wiring for microswitch for stopping the fan when fire damper closes.
For on/off/remote and local operation, 3 pole single throw switch shall be provided in each AHU panel to
facilitate override of the automatic operation.
All starters shall be provided with suitable potential free contract for connections to the Building
Automation System.
4 Nos of Single Pole MCB's Shall be provided at the incoming section of the starter panel for DDC Panel
fire damper actuator & spares.
220 / 24 V Transformer
Bypass DOL Starter with Auto / Manual & VFD / DOL Change Over Switch
Thermostat to be provided on Return Air Filter with Display integrated with VFD
13.1 Control panel suitable for minimum 15 kW fan motor. Nos. 2.00 1,26,250.00
14 SITC of Inline toilet Exhaust air fan with 15mm ESP as per given capacity & specifications.
a 1000 cfm Nos. 4.00 14,645.00
b 900 cfm Nos. 4.00 13,130.00
15.1 Propeller type exhaust fan for exhaust.
a 1000 cfm Nos. 2.00 8,585.00
b 550 cfm Nos. 1.00 7,575.00
c 350 cfm Nos. 1.00 5,302.50
d 300 cfm Nos. 1.00 4,242.00
e 100 cfm Nos. 10.00 3,737.00
15.2 FANS FOR SMOKE EXHAUST AIR - FIRE
Supply, Installation, Testing and Commissioning of Dual speed ceiling / Floor mounted Tube Direct
driven Axial Flow Fans with adjustable pitch blade, MS Powder Coated / GI long casing, cast aluminum
alloy impeller complete with TEFC Sq. Cage Induction Motor ( IE-2 High Efficiency /Eff-2) suitable for
415 Volts ± 10%, 50 HZ ± 3%, three phase A.C. supply with support, mountings, cushy foot type vibration
isolators, fire retardant flexible canvass connector 150 mm deep (Inlet & Outlet as required ), bird screen (
Inlet & Outlet as required ),inlet bell mouth/inlet cone, outlet cone if required to match the sound criteria]
etc., of following capacity. The complete fan along with motor shall be suitable for 300 °C temperature
rated for 2 hours. Axial Fan shall comply with Air Sound performance in accordance to AMCA 210 for air
performance and AMCA 300 for sound performance. Complete Fan shall be tested and approved as per
High-Temperature CE Certification in accordance with CPR (EU-305/2011) & EN 12101-3:2015 for
more than 1000mm and not more than 70DBa for fan diameter less 1000mm.
Fan include with silencer to reduce noise level include in given rate.
i. Basement -2 , Car Parking Area Nos. 4.00 1,21,200.00
Air Qty. = Singe speed -20000 CFM
Static Pressure = 25 mm Wg
Sr. No. Description Unit Total Qty Rate Amount
Fan Speed = Not exceeding 1000 rpm
Outlet Velocity = Not exceeding 14 m/s
Tube Axial Fans as described above.
ii. Basement -1 , Car Parking Area Nos. 4.00 1,21,200.00
Air Qty. = Singe speed -20000 CFM
Static Pressure = 25 mm Wg
Fan Speed = Not exceeding 1000 rpm
Outlet Velocity = Not exceeding 14 m/s
Tube Axial Fans as described above.
15.3 FANS FOR FRESH AIR.
Supply, Installation, Testing and Commissioning of ceiling / Floor mounted Tube Axial Flow Fans with
adjustable pitch blade, MS / GI long casing, cast aluminum alloy impeller complete with TEFC Sq. Cage
Induction Motor suitable for 415 Volts ± 10%, 50 HZ ± 3%, three phase A.C. supply with support,
mountings, vibration isolators, fire retardant flexible canvass connector 150 mm deep ( Inlet & Outlet as
required ), bird screen ( Inlet & Outlet as required ) etc., of following capacity.
Axial Fan shall be AMCA Certified for Air Sound performance in accordance to AMCA 210 and AMCA
Fan include with silencer to reduce noise level include in given rate.
i. Basement -2 , Car Parking Area Nos. 4.00 75,750.00
Air Qty. = Singe speed - 20000 CFM
Static Pressure = 25 mm Wg
Fan Speed = Not exceeding 1000 rpm
Outlet Velocity = Not exceeding 14 m/s
Tube Axial Fans as described above.
ii. Basement -1 , Car Parking Area Nos. 4.00 75,750.00
Air Qty. = Singe speed - 20000 CFM
Static Pressure = 25 mm Wg
Fan Speed = Not exceeding 1000 rpm
Outlet Velocity = Not exceeding 14 m/s
Tube Axial Fans as described above.
15.4 FANS FOR SMOKE EXHAUST AIR - FIRE
Supply, Installation, Testing and Commissioning of Dual speed ceiling / Floor mounted Tube Direct
driven Axial Flow Fans with adjustable pitch blade, MS Powder Coated / GI long casing, cast aluminum
alloy impeller complete with TEFC Sq. Cage Induction Motor ( IE-2 High Efficiency /Eff-2) suitable for
415 Volts ± 10%, 50 HZ ± 3%, three phase A.C. supply with support, mountings, cushy foot type vibration
isolators, fire retardant flexible canvass connector 150 mm deep (Inlet & Outlet as required ), bird screen (
Inlet & Outlet as required ),inlet bell mouth/inlet cone, outlet cone if required to match the sound criteria]
etc., of following capacity. The complete fan along with motor shall be suitable for 300 °C temperature
rated for 2 hours. Axial Fan shall comply with Air Sound performance in accordance to AMCA 210 for air
performance and AMCA 300 for sound performance. Complete Fan shall be tested and approved as per
High-Temperature CE Certification in accordance with CPR (EU-305/2011) & EN 12101-3:2015 for
more than 1000mm and not more than 70DBa for fan diameter less 1000mm.
Fan include with silencer to reduce noise level include in given rate.
Auditorium Area
Air Qty. = Singe speed -10000 CFM Nos. 4.00 75,750.00
Static Pressure = 25 mm Wg
Fan Speed = Not exceeding 1000 rpm
Outlet Velocity = Not exceeding 14 m/s
Tube Axial Fans as described above.
15.5 DUCT LESS JET FANS
Sr. No. Description Unit Total Qty Rate Amount
Supply, Installation, Testing & Commissioning & Handing over of Impulse JET THRUST Dual Speed
Ductless Ventilation / Jet fans. The fan shall be assembled with Silencer, terminal box, mounting bracket,
protection guard, deflector/guide vane, Casing, impeller, transformer, starter & motor (the entire motor fan,
controller etc., as a full package), The fan shall have adjustable aluminium impeller. The casing shall be
made of aluminium/galvanized steel with steel with flanges from both ends. The fan motor shall be used
FLP type also suitable for single/two speed motor also compatible with BMS system. The complete fan
assembly with casing, impeller and motor shall be used only imported also tested at 300º C for 2 hours
operation. Final qunatity, Direction of discharge & rotation position shall be as per the approved CFD
Analysis and Shop drawings.
Basement -2,Car Parking Area Nos. 14.00 50,500.00
Basement -1,Car Parking Area Nos. 14.00 50,500.00
SITC of Crossflow heat exchanger without coil double skin construction FOR FRESH AIR &
EXHAUST AIR SYSTEM. The unit shall comprise of filter section, heat recovery unit, inlets and outlets
for fresh air / exhaust air , fan section with DIDW fan with motor and drive package. The unit shall be
installed nearer to toilet ceiling and interconnected in a manner so as to receive part return air thru public
area which shall be passed through HRU and transfer sensible cooling to incoming fresh air. The treated
fresh air shall let into the Return Air path of IDU / Fresh Air ports of Standard IDUs and hot exhaust air
shall be released to ambient. The exhaust section of the unit shall be provided with motor actuated GSS
damper duly interlocked with the fan. Minimum sensible and latent heat transfer efficiency of heat
recovery unit shall be 70%. The Noise level shall not be < 45 dB at 1 meter distance with inbuilt remote
controller system. The Scope Includes SITC of VFD Starter Panel for Fresh air and Exhaust air fans with
Design conditions shall be as follows
Fresh Air at the Inlet of HRU
Summer Conditions
DB 110 deg F
WB 73 deg F
Monsoon Conditions
DB 89.1 deg F
WB 82.8 deg F
Exhaust Air Temp. at the Inlet of HRU
DB 78 deg F
Thermal efficiency minimum 60% in summer.
External Static pressure on Fresh and exhaust fan : 20 mm
Note : At fresh air suction side required MERV-8 filter & Exhaust air side require bird screen included in
given rate.
i. 5000 cfm Fresh Air / 5000 cfm Exhaust Nos. 2.00 2,82,800.00
16 SITC of Factory Fabricated Ducts as per "SMACNA" Standards (For toilet exhaust)
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal
rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes,
hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete
as required.
a Thickness 1.2 mm (18 Gauge) Sq. Mtr. 105.00 1,679.63
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without
16.2 volume control dampers complete as per specifications and size & shape as per site requirement and Sq. Mtr. 2.50 7,073.03
approved design.
Sr. No. Description Unit Total Qty Rate Amount
SITC of Water treatment Plant for HVAC System suitable for local raw water intake to convert in soft
water suitable for cooling tower make up purpose having TDS level up to 500 PPM and PH value around
6.5 of Resin bed technology type with complete with PVC storage tank of suitable capacity, Monoblock
Pumping system, allied C PVC piping network with allied shut off valves, Strainer, Level indicators,
17 pressure gauges, online water quality measuring instrument, drain, make up and quick fill connections with Lot 1.00 3,53,500.00
valves, including electrical starter panel etc.with 1 nos pumps (1W+1SB) for raw water softner to to make
up water system). water store in tank with 2#20000 ltr PVC water tank with three layer insulation (1#
For Raw water + 1# Soft water storage ) included in cost. The Scope also Includes SITC of PLC Panel
with required Power / Control Cabling (Max 25 Mtr).
a WTP Feed pump From Raw water to Soft water tank(pump room)
Capacity/each pump Flow Rate - 3.0 m3/hr
Head - 25.00 m
1 Set = 2 Nos. pump (1 working+1 standby), cascade operation
Approx. Elec. Load. - 1.5 KW each pump
Location : Submerge RAW WATER TANK
c UPVC Sch 80 piping distribution
Providing, fixing, testing and commissioning of UPVC SHD 80 Pipe with Elbow , tee , Coupler , & Ball
Valves complete for interconnecting piping Works in single lot (50 mtr),
Providing and erecting approved make split air-conditioning unit consisting of copper condensing
unit with fan motor, hermetically sealed rotary compressor with accessories etc. duly connected
separately erected evaporating unit and blower motor with its accessories by means of extra
supplied proper insulated copper tubing,drain PVC pipes suitable for ( cost includes powder coated
Stand, Eco Friendly green gas charging, 15A plug top & Remote Control) with necessary core
For 3 Star Rating of current year
a 2.0 TR Nos 2.00 46,288.30
DUCTABLE SPLIT AIR-CONDITIONERS
Providing and erecting approved make ductable split Air Conditioning unit each consist of remote
located condensing unit and an evaporating unit complete with interconnecting insulated refrigerant
piping up to 10 RMT. rigid PVC, drain piping of 10 kg / cm2 dully insulated with nitrile rubber insulation
20.2 of 10 RMT with ECO Friendly Green gas. The condensing unit is complete with hermetically sealed
scroll compressor & condenser unit which effectively achieves heat rejection by utilizing air of fan and
coil type condenser. The evaporating unit will be complete with DX evaporator centrifugal blower,
blower motor along with microprocessor biased remote controller with memory backup etc.
11.5 TR / 4600 CFM CEILING SUSPENDED UNIT Nos 2.00 2,55,062.37
Supplying and erecting insulated pair of soft copper tubing including power and control cable,necessary
PVC drain pipes for Split AC machine up to 4 TR capacity
Supplying & installing MS standard type stand mounting for outdoor unit of Split A.C. upto 4 TR capacity
erected with necessary hardware materials as directed.
24.0 HVAC Panel and Electrical Cabling
Supply, Installation, testing and commissioning of Cubicle type, dead front, sheet steel, wall mounted
control panels including anchoring into the wall, wiring, incoming, earthing & terminating into MCCB
/MCB in each panel.
BMS. All starters shall be provided with potential free Contact for Connections to Fire Signal / Building
Automation System.
The panel shall include the following components and accessories.
Suitable rating Incoming MCCB for fan motors as per the ratings given below, MCCB shall be suitable for
motor duty and able to withstand fault level of 20 KA.
Sr. No. Description Unit Total Qty Rate Amount
VFD (part of EC fan) starter with input/Output chock arrangement as outgoing for each fan motor as per
KW ratings
Terminal block for power distribution.
Contactor, over load relay with built in single phasing protection.
Phase indicating lights and indicating light for ON status.
Time delay relay for delayed automatic restart of air handling / Ventilation unit motor.
Wiring for microswitch for stopping the fan when fire damper closes.
All starters shall be provided with suitable potential free contract for connections to the Building
Automation System (To stop the equipment in case of fire / distress call ).
4 Nos of Single Pole MCB's Shall be provided at the incoming section of the starter panel for DDC Panel
220 / 24 V Transformer
For on/off/remote and local operation, 3 pole single throw switch shall be provided in each AHU panel to
facilitate override of the automatic operation.
This shall include Supply and erection of electrical cables of required size as per capacity of
equipment and length required including cable tray, lugs , grands etc as complete system from
panel to various equipments.
SITC of Motor Control Centre for HVAC EQUIPMENTS: Supply, installation, testing and commissioning
of the following cubicle type 2 mm thick sheet steel in cubical formation, compartmentalized in Form 3b
Construction, floor mounted, free standing and shall be dust and vermin proof., front operated, rear
connections indoor type LT motor control panel, drawout/hinged and lockable doors, complete with
24.1 internal wiring, cabling, cable tray, colour coding with ferrules, cable glands, bonding to earth and
through BAS. All starters shall be provided with potential free Contact for Connections to Building
Automation System.listed below with 10% spare fedeer of highest capacity refer SLD drawing in HVAC
Incoming :
Incoming : 1000 A,4P,50 KA,,ACB with Comm. & BMS Compatibility LSIG protection Micro processor
based release (O/L,S/C,E/F PROTE.) with CT and MFM & ON ,OFF ,TRIP & RYB indication lamps,
Potential free contacts for BMS compatibilty.
Phase indicating lamps backed up with control MCBs.
TPN bus bars shall be of Aluminium and shall be provided with heat shrinkable color coded PVC sleeves.
Phase bus bars shall be rated at 1600 amps and neutral bus bar shall be of 50% capacity.
Maximum density of Aluminium bus bars for current carrying capacity shall be 1.0 amp per square mm.
3 # Suitable amps 4P MCCB with release for over current, short circuit and earth fault protection for main
power supply to 125 TR Water Cooled Chiller Panel (2 Working + 1 Stand by). The compartment shall
with MCB for ‘ON/OFF/TRIP’ status of Chillers
3 # suitable amps 4P MCCB with star delta starters, with over load relays with built in single phasing
protection and outgoing feeders to Cooling Towers (2 Working + 1 Stand by) fan motor. Each of these
indicating lamp with MCB and toggle switch for ‘ON/OFF/TRIP’ status of pump motors.
Sr. No. Description Unit Total Qty Rate Amount
3 # suitable amps 4P MCCBs, suitable star delta starters, with over load relays with built in single
phasing protection and outgoing feeders to primary chilled water pumps (2 Working + 1 Stand by )
motors. Each of these compartment shall contain CT operated digital ammeter of 0-40 amps range with
3 # suitable amps 4P MCCBs, suitable star delta starters, with over load relays with built in single
phasing protection and outgoing feeders to condenser water pumps (2 Working + 1 Stand by ) motors.
switch, and an indicating lamp with MCB and toggle switch for ‘ON/OFF/TRIP’status of pump motors.
3 # suitable amps 4P (TPN) MCCB for outgoing feeders to variable Frequency Drive (VFD) panel of
suitable Variable Flow Secondary Chilled Water pumps (1 Working) motors. Each of these
indicating lamp with MCB for ‘ON/OFF/TRIP’ status of pump motors.
2 # Providing & erecting 415 V, 4-Pole MCCBs, for Motor & Inductive Load (D Curve) having 25KA
breaking capacity & confirms to IS :8828 in existing box having for Pressurization pumping system (1
1 # Providing & erecting 415 V, 2-Pole MCCBs, for Motor & Inductive Load (D Curve) having 25KA
breaking capacity & confirms to IS :8828 in existing box having for Automatic Tube Cleaning system (1
1 # Providing & erecting 415 V, 4-Pole MCCBs, for Motor & Inductive Load (D Curve) having 25KA
breaking capacity & confirms to IS :8828 in existing box having for CPM (1 Working ) 32 amps with
1 # Providing & erecting 415 V, 4-Pole MCCBs, for Motor & Inductive Load (D Curve) having 25KA
breaking capacity & confirms to IS :8828 in existing box having for Water treatment Plant ( Softner
1 # Providing & erecting 415 V, 2-Pole MCBs, for Motor & Inductive Load (D Curve) having 10KA
breaking capacity & confirms to IS :8828 in existing box having for Plant room ventilation System (1
7 # suitable amps 4P MCCBs, suitable star delta starters, with over load relays with built in single
phasing protection and outgoing feeders to AHU (2 Working ) motors. Each of these compartment shall
and toggle switch for ‘ON/OFF/TRIP’status of pump motors.
Spare for following :
One Spare feeder with suitable switchgear each for Chiller, CHW Pump and CT
Necessary cable alleys, space for spare switches, internal wiring, and copper earthing of equipment shall
also be included. All switches and other components shall be motor duty rating.
24.2 Electrical Cabling Work
ARMOURED COPPER CABLES
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for
KV. to be laid in suitable cable trays and with required terminations
a (a) 4 core 10 Sq. mm. Rmt. 40.00 140.39
b (b) 4 core 16 Sq. mm. Rmt. 180.00 153.52
c (c) 4 core 2.5 Sq. mm. Rmt. 240.00 168.67
d (d) 3.5core 150 Sq. mm Rmt. 30.00 731.24
24.3 Earthing or Earthing strip for all equipments
Providing and erecting required size HOT deep Galvanised iron strip for earthing of H.T. , OCB/ ACB/
Transformer LT panel board, Motors etc. using proper clamp.
Sr. No. Description Unit Total Qty Rate Amount
Supplying & erecting earth pit of minimum bore dia.150mm size approved make Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free hot dipped G.I.Pipes
having Outer pipe dia of 50mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-
250 Micron galvanising, connection terminal dia of 12mm with constant ohmic value surrounded by highly
conductive compound with high charge dissipation suitable for following type of applications with
chamber and heavy duty cover.(approved make OEM has to submit test certificate) & having back filling
2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2%(C) Back fill Compound :-
Earthing compound should be capable to retain moisture for long time Necessary test report must be
submitted.
(b)For Electrical installation up to 11 KV in normal soil.
1.0 Length of Pipe : 2.00 mtrs Nos 3.00 5,760.03
Back filling Compound :1 no. Bag of 25 Kg.
SITC of Providing and fixing approved make Perforated C type cable tray. Made from sheet steel. The
cable tray should be single or double bended as per required and as per IS 2062/1079 and shall be coated
24.3 with hot dip galvanizing as per IS 2629/4759. with max 17.5% perforation with coupler plate / Fish plate
and GI hardware like nut - bolt and washers etc. erection with necessary support( included) as per
Specification and as per instruction of engineer in charge..
a (7) 600 X 50 X 2.0 mm Thick Rmt. 25.00 1,006.97
b (6) 450 X 50 X 2.0 mm Thick Rmt. 30.00 801.94
c (5) 300 X 50 X 2.0 mm Thick Rmt. 35.00 622.16
d (4) 200 X 50 X 1.6 mm Thick Rmt. 35.00 496.92
Providing and fixing approved make 'T' Junction for Perforated C type cable tray. Made from sheet steel.
The Junction should be bended as per IS 2062/1079 and shall be coated with hot dip galvanizing as per IS
24.5 2629/4759. with max 17.5% perforation with coupler plate / Fish plate and GI hardware like nut - bolt and
washers etc. erected on existing support as per Specification and as per instruction of engineer in charge..
OF FOLLOWING SIZE
a (7) 600 X 50 X 2.0 mm Thick Nos 6.00 823.15
b (6) 450 X 50 X 2.0 mm Thick Nos 10.00 549.44
c (5) 300 X 50 X 2.0 mm Thick Nos 28.00 291.89
d (4) 200 X 50 X 1.6 mm Thick Nos 11.00 214.12
Providing and fixing approved make '90° Elbow' for Perforated C type cable tray. Made from sheet steel.
The Junction should be bended as per IS 2062/1079 and shall be coated with hot dip galvanizing as per IS
2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on
existing support as per Specification and as per instruction of engineer in charge..
a (7) 600 X 50 X 2.0 mm Thick 90° Elbow Nos 5.00 694.88
b (6) 450 X 50 X 2.0 mm Thick 90° Elbow Nos 10.00 446.42
c (5) 300 X 50 X 2.0 mm Thick 90° Elbow Nos 5.00 245.43
d (4)200 X 50 X 1.6 mm Thick 90° Elbow Nos 6.00 171.70
Providing and fixing approved make 'Cross over Junction' for Perforated C type cable tray. Made from
sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated with hot dip
24.7 galvanizing as per IS 2629/4759. with max 17.5% perforation with coupler plate / Fish plate and GI
hardware like nut - bolt and washers etc. erected on existing support as per Specification and as per
instruction of engineer in charge..
a 600 X 50 X 2.0 mm Thick Cross Junction Nos 6.00 985.76
b 450 X 50 X 2.0 mm Thick Cross Junction Nos 5.00 672.66
c 300 X 50 X 2.0mm Thick Cross Junction Nos 10.00 373.70
d 200 X 50 X 1.6 mm Thick Cross Junction Nos 6.00 282.80
25 SITC of Mild Steel material for preparation of MS structure of plant room etc. Kgs 1000.00 151.50
Total Cost of S.I.T.C. of HVAC Work
Sr. No. Description Unit Total Qty Rate Amount
A.M.C. Charges for 3 Years of Post DLP
All inclusive maintenance charges for the entire system after completion of Defect Liability Period of
26 years. (The contractor to ensure all critical spares parts availbility for minimum 15 years from the
date of takig over the Chiller System by Client.)
26.01 1st year Per Year 1.00 12,92,296.40
26.02 2 year Per Year 1.00 12,92,296.40
26.03 3rd year Per Year 1.00 12,92,296.40
Total Cost of A.M.C. for 3 Years of Post D.L.P.
Operation Charges for 5 Years
27.01 Per Month 12.00 35,532.00
27.02 Per Month 12.00 37,308.60
27.03 Per Month 12.00 39,174.03
27.04 Per Month 12.00 41,132.73
27.05 Per Month 12.00 43,189.37
Total Cost of Operation for 5 Years
Total Cost of HVAC work including 3 Years of Maintanance and 5 Years of Operation
Construction of Auditorium At TP No 124C, FP No 31 (Social Infrastructure), in Thhakarnagar Ward, North Zone, Ahmedabad.
BOQ of Audio-Video Work
Quantity Item Description Rate Unit Amount
Most powerful compact active line array loudspeakers, LF:1000W, HF:500W It delivers 139db at 65-
20Khz, all from a 31.7lb Baltic birch, steel and aluminum enclosure , LF 2×6.5″ cone, 2″ VC Vented HF
1 16.00 1×1″ exit, 1.75″ VC compression AHD (Adjustable Horizontal Directivity) with field adjustable horn 10,03,490.00 Nos
flairs providing a path to multiple coverage patterns. Nom. Beamwidth: Vertical: 10°, Horizontal –
Narrow 80° – Wide 110° – Asymmetrical (95° left or right of center)
Flybar Kit like Flybar & Groundstack Adapter, Stinger w/Link Bracket , M20 Mount Adapter , Pole
Mount Adapter
DUAL 18 INCH SELF-POWERED SUBWOOFER Power Handling 1400W , acoustical design and DSP
including Focusing™ and DynO™ provides a pristine impulse response at all output levels. Integrated
3 4.00 Dante™ networking (with loop-thru) on all models including Analog redundancy capability. Frequency 11,15,132.00 Nos
Response 27 Hz -125 Hz, Max SPL 141 dB (Half Space), Operating Mode Single-amp LF; DSP w/
Dyn0™, Subsystem 2 x 18 in cone, 3 in voice coil
2-Way Full-Range Dual-Woofer LoudspeakerUltra compact multipurpose , 250W@8ohms , vast range of
fill applications Weather protection and transformer options Frequency Response 75hz-20khz, Max SPL
127dB, Operating Mode LF/HF, DSP w/ EAW Focusing & DynO Subsystem LF Transducer – 2×5.25″
Cone, 1.25″ VC HF Transducer – 1×1-in exit, 35mm voice coil compression driver, Horn loaded
Amplifiers is the perfect match for any externally-powered loudspeaker• 4-input, 4 channel amplifier
2500W/ch with 4Ω nominal load, 5000W/bridged ch-pair with 4Ω nominal load , AES3 and Dante™
input.Greybox-enabled ,Engineered specifically to load GreyboxesTM, incorporates high performance
amplification, DSP (including FocusingTM and DynOTM) and Dante networking into a compact
rackmount electronics package.Multiple power levels and channel, front panel with quick setup
functions.
2-WAY SELF-POWERED LOUDSPEAKER bi-amplified electronics (1500W) featuring signature DSP
6 12.00 including Frequency Response 50 Hz – 20 kHz, Max SPL 138dB, Operating Mode Bi-Amp LF, HF 5,64,742.00 Nos
subsystem 15 in Cone, 3 in Voice Coil 3 in Voice Coil Neodymium Compression Driver.
2-WAY SELF-POWERED LOUDSPEAKER portable and lightweight wooden enclosure. onboard bi-
amplified electronics (1500W) featuring signature DSP including Focusing and DynO, Frequency
Response 55 Hz – 20 kHz, Max SPL 135dB, Operating Mode Bi-Amp LF, HF 12 in Cone, 2.5 in Voice
Coil 1.4 in Voice Coil Compression Driver, 1 in Exit
Quantity Item Description Rate Unit Amount
LOUDSPEAKER MANAGEMENT SYSTEM professional-grade digital speaker management system,
designed to deliver precise control and advanced audio processing for multi-speaker environments.
8 1.00 Featuring an interactive LCD and an intuitive embedded GUI, it enables quick, efficient parameter 1,83,563.00 Nos
adjustments and system management. Equipped with a stable, linear-phase 512-tap custom FIR filter,4 IN
9 12.00 Active loudspeaker 30 W RMS. 6.5'' Woofer + 1'' Tweeter. LF 6.5" Woofer ,HF 1" Tweeter 85,422.00 Nos
Digital Mixing Console, Compact is a Dante-equipped versatile digital mixing console with unparalleled
sound quality, ease of operation, and high reliability that make it perfect for a wide range of applications.
mixer Compact is configured with 12 + 4 faders and a 1 x 12” + 1 x 7” multi-touch screen, and a rack-
10 1.00 mountable with an optional RK1 rack mount kit , input mixing channels: 72 mono, Buses: 48 Mix + 12 26,73,750.00 Nos
Matrix + 2 Stereo, Display: 12.1" multi-touch screen x 1, 7" multitouch screen x 1, Faders: 16 (12 + 4),
Analog I/O: 16 inputs / 16 outputs ,Dante: 144 in / 144 out, AES/EBU: 1 out, Slot: PY Slot x 1 ,USB
Audio Interface: 18 in / 18 out
I/O rack is compatible consoles as well as the RIVAGE PM series. It features 32 analog inputs,
analog outputs, and eight digital AES/EBU outputs. connects directly to Dante digital audio networks,
allowing flexible system configuration. Dual power supply units are built in for high reliability, and a
11 1.00 character/graphic display offers easy visual confirmation. 32 analog inputs and 16 outputs, and 8 digital 14,26,000.00 Nos
outputs. Redundant connections are supported with primary and secondary connectors. Daisy chain
connections are also supported. Comprehensive display and local control of gain and other parameters.
Dual power supply units are built in for high reliability.
32-Channel Premium Mixing Console, Serious Capacity for Live Sound & Installations, 24 Mic Inputs
12 2.00 with 48V Phantom Power and HPF per Channel , 32 Line Inputs (24 mono and 4 stereo), 6 AUX Sends + 2,05,850.00 Nos
2 FX Sends , 4 GROUP Buses + ST Bus, 2 Matrix out, 1 Mono out
technology,Should have UHF operating mode with Frequency range of 522 -930Mhz or better, Should
have operating bandwidth 134 MHz or better, Anti Interference technology ensures Noiselock Squelch
effectively blocks Stray RF or better, Microphone Frequency Response of 45Hz to 18KHz or better,
Should have Signal to noise ratio less then 104dB or better, RF output Power of 10/40mW or better,
Should have maximum 24 set can be used simultaneously by using multiple frequency bands in one
venue, Should have die cast metal body, Microphone element Dynamic or better complete with standard
accessories required as per tender.
technology, Should have UHF operating mode with Frequency range of 522 -930Mhz or better, Should
have operating bandwidth 134 MHz or better, Anti Interference technology ensures Noiselock Squelch
effectively blocks Stray RF or better, Microphone Frequency Response of 45Hz to 18Khz or better,
Should have Signal to noise ratio less then 104dB or better, RF output Power of 10/40mW or better,
Should have maximum 24 set can be used simultaneously by using multiple frequency bands in one
venue, Should have die cast metal body .Microphone element should unidirectional capsule or better
complete with standard accessories required as per tender.
Vocal Dynamic Microphone Categories: Dynamic Microphone Capsule Type,Polar Pattern Cardioid
15 4.00 Unidirectional ,Frequency Response 50Hz - 14KHz (+- 3dB),Sensitivity -58 dB (1V/Pa) Output 9,177.00 Nos
Impedance600 Ω , Max sound pressure level 140dB (1KHz at 1% T.H.D)
Quantity Item Description Rate Unit Amount
Electret-condenser microphone features a cardioid polar pattern, ideal for capturing sound primarily from
the front while minimizing noise from the sides and rear. Its frequency range spans from 80Hz to
18,000Hz, covering a broad spectrum of audio frequencies. With an open circuit sensitivity of 55dB±3
(0 dB=1V/microbar 1000Hz indicated by open circuit), it effectively captures sound with clarity and
precision. The microphone has an impedance of 100+30% Ohms at 1000Hz. It can handle a maximum
input sound level of 115dB SPL (Sound Pressure Level) at 1KHz with 1% Total Harmonic Distortion
(T.H.D.), providing distortion-free recording even at high sound pressure levels. The dynamic range is
82dB at 1KHz at maximum SPL, ensuring detailed audio capture across various sound levels. The
microphone offers a signal-to-noise ratio of 61dB at 1KHz with 1Pa, allowing for clear audio
reproduction with minimal background noise. It operates on phantom power ranging from 11-52V DC,
with a typical current draw of 2mA. Control features include a membrane-touching switch, with ON/OFF
offers a bass filter switch with options for Flat and Roll-Off settings, providing flexibility in audio
capture depending on the recording environment and desired sound characteristics.
Antenna Distribution System by redefines wireless microphone setups with its advanced four-way
antenna distribution system. By effectively mitigating signal dropouts caused by interference, it ensures
17 1.00 seamless audio transmission to multiple receivers. With its integrated power supplies guaranteeing 4,45,625.00 Nos
consistent performance, the ADS stands as an indispensable choice for professionals seeking reliable and
efficient wireless solutions. for 1 set
Overhead microphone delivers clear, accurate audio with interchangeable cartridges and an unobtrusive,
bright white or black design. Wide dynamic range and frequency response for accurate sound
18 8.00 reproduction across the audio spectrum, ransducer Type Condenser 48,876.15 Nos
Polar Patter Cardioid, Frequency Range (Hz)50
-(kHz)17, Sensitivity dBV/Pa Cardioid: -35.00, Impedance (Ω) Rated: 150 / Actual:
Boundary microphone provides high-quality sound for a wide range of applications due to its
interchangeable condenser cartridge. It features programmable, silent membrane switches, LED
indicators, and a low-profile design. Polar Pattern Cardioid, Frequency Range From (Hz)50- (kHz)
Sensitivity dBV/Pa Cardioid: -30.00, Impedance (Ω) Rated: 150 / Actual:
SITC Of Gooseneck, 18" with cardioid nterchangeable cartridges provide the right polar pattern for every
20 2.00 application Locking flange mount for permanently securing microphone to surfaces, Snap-fit foam 40,003.90 Nos
windscreen Shock mount provides over 20 dB isolation from surface vibration noise
SITC Of Vocal Microphone Neodymium magnet for high signal–to–noise output, Hardened steel mesh
grille that resists wear and abuse
SITC Of Dynamic Vocal Microphone Frequency response tailored for vocals, with brightened midrange
22 3.00 and bass rolloff Uniform cardioid pickup pattern isolates the main sound source and minimizes 20,598.80 Nos
background noise
23 8.00 SITC Of Vocal Microphone Dynamic cartridge with cardioid polar pattern 4,179.10 Nos
SITC Of Drum Microphone Kit is a complete package of professional quality microphones, designed to
provide excellent sound for full drum kit performance and recording. Included in the Kit are one kick
drum microphone, three drum microphones, one instrument microphone and two instrument microphones,
along with three drum mounts, seven XLR-XLR cables, and a carrying case.
Quantity Item Description Rate Unit Amount
SITC Of 32 U Hight 600x800 W x D Rack with A full range of accessories can be loaded with a full
security system to prevent unauthorised access to vital equipments within the cabinet, Functional cable
management all along the height, Direct mounting of fan on the top cover allows maximum height
utilization, Canopy fitted on the top cover prevents ingress of dirt, dust and water inside the cabinet.
26 2.00 SITC Of Popup Box with Hdmi, VGA, Power 20,897.80 NO.
27 5200.00 SITC Of 2 core Audio cable 226.55 Mtrs.
28 1400.00 SITC Of Speaker Cable 2.5 sqmm, High-Conductivity Copper Cable Twisted Jacket Con. 277.15 Mtrs.
29 256.00 SITC Of Audio Connector 315.10 no.
30 28.00 SITC Of Stage box For mic input par box 4 & 6 input 5,074.95 NO.
SITC LED Par RGBW High bright luminaire provided with 54x3W LED’s of High quality 54x3W LED
PAR Light used as a Effect Light, Spot Light and Strobe Light etc. with below specifications: , Lamp:
54X3 WRGBW LED (12R+18G+18B+6W),Max. Power consumpsion: 160W , Power and DMX: Loop
in and loop out
SITC of High quality POINTEY Moving Head 280w Beem-Sport -Wash (BSW) light used as a special
32 6.00 effect light providedwith high precision gobos and colors for entertainment lighting etc. with below 1,56,733.50 Nos
specification: Lamp: Philips / Osram MSD Platinum 10R, 8000K MAX.
SITC of LED BLINDER LIGHT WITH FLICKER-FREE, SPECTATOR LAMP , USING FOUR RGB
WARM WHITE (3200K) OR COOL WHITE (5600K) COB LED BEADLETS. LAMP : 4 PCS 100W
COB LED, NO UV RADIATION ,BEAM ANGLE : 60°, CCT : 3000K/4000K/6500K, LIFE TIME :
33 12.00 50000 HRS,· DIMMER : 0-100% LINEAR LIGHT DIMMERING , STROBE : 0-30 F/S, RANDOM 25,226.40 Nos
OR PULSE, SPEED ADJUSTABLE, CONTROL MODE : DMX512, AUTO, SOUND, MASTER-
SLAVE, DMX CHANNELS : 8 CHANNELS , DISPLAY : LCD DISPLAY , INPUT VOLTAGE : AC
100-240V 50-60HZ, POWER : 400W
SITC of High quality 200W LED COB Warm White Light provided with 3000K CCT, Power loop in and
34 10.00 loop out arrangement, high quality COB lens source, wide beam angle, CRI, TLCI values above 95, 7,910.85 Nos
DmX and manual control option with black powder coated matt black finish paint.
SITC of motorized automatic stage Lighting Bar with Up to 70ft up down with all required Accessories
like Pipe, Motors min. 3 hp, Wires,cable ,Starter and clamping. Which to be used as up to 16m lighting
bar as instructed bu engineer incharge and frill bar made of SCH-40 NB dual berrel of 3.68 mm thickness
along in from of tripod structure(no sag ) with 3HP/4HP 1PH/ 3 PH AC motor with DC brake as per all
weight load requirement. Necessary pully, guide pullys GI wire rope of minimum 5mm in diameter
constructed with 6 bundles of 19 strands with fibre core at winding drum. Specially designed compact
worm gear box upper and lower limit controller requisite cable trunking arrangement ensuring all the
cable from C track to the lighting bar to be enclosed in it
SITC of Connectors like DLX,, XLR,(Male /Female) with required all accessories to complete work
Make: Liteputer/ Amphenol/ Nuetrick
SITC of DLX /XLR DMX signal cable for DMX network. 5/3 Core DmX Cable with sheathed
37 200.00 protection, low noise and twisted pair cable with 0.2mm conductor protected and insulated with the PVC 193.20 Mtr
sheathing.
Quantity Item Description Rate Unit Amount
SITC of DmX Out Junction boxes provided with 5/3 Pin XLR Female connector locking type having
fabricated box made up of MS sheet .
SITC of DmX Loop Junction boxes provided with 5/3 Pin XLR Male & Female connector locking type
having fabricated box made up of MS sheet
SITC of XLR Loop Cable 1.5 to 2 Mtr length (Ready to use for Connect) - DmX Loop cable 2 Mtrs
40 68.00 length provided with male female connectors 5 /3 Pin configuration, duly soldered and provided with 5 2,096.45 Nos
Core DmX flexible low resistance cable sheathed protection.
SITC of LED MOVING ZOOM WASH 19 PCS 15W HIGH BRIGHTNESS RGBW LED BEAM
ANGLE : 8°-50° CCT : 2700-6500K, LIFE TIME : 50000 HRS, EFFECT : 3 RING CONTROL WITH
BUILT IN PROGRAMS & MACRO EFFECTS, DIMMER : 0-100% LINEAR LIGHT DIMMERING,
· STROBE : 0-20 F/S, RANDOM OR PULSE, SPEED ADJUSTABLE, · PAN & TILT : PAN- 540° (16-
BIT) TILT- 270° (16-BIT), CONTROL MODE : DMX512, AUTO, SOUND, MASTER-SLAVE
CONTROL CHANNEL : 16/24 CHANNELS , DISPLAY : LCD DISPLAY200W LED Fresnel Spot
light 3200K provided with Zoom manual beam angle adjustment from 10 ~ 50 Degree, high quality
german lens
SITC Of 2010 DMX CONTROLING CONSOL Bulit-in memory, Internal Flash Drive, similar in
functionality to a hard disk but faster and more rugged. Provides enough storage for:- The entire Fixture
centralized control channel. Theater Mode and Playback. Graphics geherator, can quickly generate
graphics and effects. 15 playback laders can control 450 memory. running lights or CUE list Trigger
midi, bass, tenor,treble voice of Including the VGA output for external display. Increase the USB
memory, it can store more than one set of library files and documents show.or arena.
SITC of Industry Standared dimming / dimmer Rackmount 12channel (12chx4KW) DMX Dimmer pack
43 1.00 with following features and Specifications: Features: Automatic frequencysensor candetect 84,934.00 Nos
powerfrequency(45Hz–63Hz) indifferentareas &stabilizes the dimming output.
SITC of DMX Data RDM Splitter: 1 x IN to 8 OUTPUT DMX-512 Data Splitter Unit, with Opto-
44 2.00 Isolated outputs ;suitable both for Dimmer & Intelligent Lights,Size: suitable to 19” rack , along with 29,107.00 Nos
work for cables termination for Mains I/P & O/P,XLR Cable etc
SITC of Dimmer Rack: 19" Rack 9 U high, suitable to house 6 Nos. for dimmer splitter packs ; wall
Mount / c/w wheels ;Front Door with Toughened Glass quality Removable side panels with ventilation
provision Castor wheels set of 4 with front wheels Brake provision ,Adjustable mounting slots ,Cable
45 1.00 insertion on Top & Bottom panel to provide easy cable entry,Top section with cooling Fan ,Compatible 52,020.05 Nos
with 19" International standards ,240VAC Power socket strip as per standard with Required internal
wiring for Power Link cables for Mains I/P to all dimmers to be provided from nearst DB /Panel as per
Sugession by Client/Consultant.
PVC Copper unarmoured flexible FRLS insulated multicore cable 1100V grade confirming to IS size 3c
Total Amount of S.I.T.C. of Audio & Video Work
Total Amount of S.I.T.C. of Audio & Video Work
Quantity Item Description Rate Unit Amount
PART - A OPERATION
Providing experienced Operator : Providing experienced Operator with his personal identity card
necessary for operation of Complete Audio-Video and Stage Light system for Auditorium hall in Two
1 Shifts . time Morning 9:00 am to Night 1:00 am OR as per instruction of Engineer In charge for
days.Including reliver.Operator should have experience in Audio-Video -stage lighting system operating
of 2 years.
1.1 12.00 Total 2 (Two) Operators for 1st year (one person per shift) -During DLP 45,762.71 Month
1.2 12.00 Total 2 (Two) Operators for 2nd year (one person per shift)-After DLP 48,050.85 Month
1.3 12.00 Total 2 (Two) Operators for 3rd year (one person per shift)-After DLP 50,453.39 Month
1.2 12.00 Total 2 (Two) Operators for 4TH year (one person per shift) -After DLP 52,976.06 Month
1.3 12.00 Total 2 (Two) Operators for 5TH year (one person per shift)-After DLP 55,076.60 Month
Providing Helper : Rates for providing Helper with his personal identity card necessary as mentioned
below for operation for Complete Audio-Video and Stage Light system for Auditorium hall in Two
Shifts. time Morning 9:00 am to Night 1:00 am OR as per instruction of Engineer In charge for
days.Including reliver. Helper should have knowledge of Audio-Video-stage lighting system
2.1 12.00 Total 2 (Two) Helpers for 1st year (one person per shift)- During DLP 32,711.86 Month
2.2 12.00 Total 2 (Two) Helpers for 2nd year. (one person per shift)-After DLP 34,347.46 Month
2.3 12.00 Total 2 (Two) Helpers for 3rd year. (one person per shift)-After DLP 36,064.83 Month
2.2 12.00 Total 2 (Two) Helpers for 4TH year. (one person per shift)-After DLP 37,867.20 Month
2.3 12.00 Total 2 (Two) Helpers for 5TH year. (one person per shift)- After DLP 39,760.56 Month
PART - B COMPREHENSIVE MAINTENANCE
Comprehensive Maintenance service Contract of Complete Audio-Video -stage-lighting system
(Including all spare parts) for 1st year-During DLP
Comprehensive Maintenance service Contract of Complete Audio-Video -stage-lighting system
(Including all spare parts) for 2nd year-After DLP
Comprehensive Maintenance service Contract of Complete Audio-Video -stage-lighting system
(Including all spare parts) for 3rd year-After DLP
Comprehensive Maintenance service Contract of Complete Audio-Video -stage-lighting system
(Including all spare parts) for 2nd year-After DLP
Comprehensive Maintenance service Contract of Complete Audio-Video -stage-lighting system
(Including all spare parts) for 3rd year-After DLP
Total Amount of O & M of Audio & Video Work
Total Amount of O & M of Audio & Video Work
Total Amount of S.I.T.C. of Audio & Video with 5 Year's of O & M
Total Amount of S.I.T.C. of Audio & Video with 5 Year's of O & M
Construction of Auditorium At TP No 124C, FP No 31 (Social Infrastructure), in Thhakarnagar Ward, North Zone, Ahmedabad.
BOQ of Fire Fighting Work
Sr.No. Description Unit QTY. Rate Total Amount
Sr.No. Description Unit QTY. Rate Total Amount
A Fire Pump Room Acce. (Positive Suction).
Providing, fixing, testing and commissioning of electric driven main fire pump suitable for
automatic operation and consisting of following: Horizontal type, centrifugal End Suction
pump of cast iron body & bronze impeller , mechanical seal to ensure a minimum pressure of
1.0 3.5 kg / sq.cm. at highest and farthest outlet at specified flow of 137m3/Hour@80M. head Nos. 2 391241
conforming to IS 1520. The pump shall be coupled to TEFC motor of suitable HP & speed
and complete set shall mounted on common base frame with, coupling, coupling guard,
foundation bolts etc. as required. (Hydrant & Sprinkler System)
Providing, fixing, testing and commissioning of Diesel Engine driven fire pump suitable for
automatic operation and consisting of following: Horizontal type, centrifugal End Suction
pump of cast iron body & bronze impeller , mechanical seal to ensure a minimum pressure of
2.0 3.5 kg / sq.cm. at highest and farthest outlet at specified flow of 137m3/Hour@80M head No. 1 654882
conforming to IS 1520.The pump shall be coupled to TEFC motor of suitable HP & speed and
complete set shall mounted on common base frame with , coupling, coupling guard,
foundation bolts etc. as required
Providing, fixing, testing and commissioning of electric driven main fire pump suitable for
automatic operation and consisting of following: Horizontal type, centrifugal End Suction
pump of cast iron body & bronze impeller , mechanical seal to ensure a minimum pressure of
3.0 3.5 kg / sq.cm. at highest and farthest outlet at specified flow of 137m3/Hour@80M. head No. 1 391241
conforming to IS 1520. The pump shall be coupled to TEFC motor of suitable HP & speed
and complete set shall mounted on common base frame with, coupling, coupling guard,
foundation bolts etc. as required. ( Water Curtain System )
Providing, fixing, testing and commissioning of Diesel Engine driven fire pump suitable for
automatic operation and consisting of following: Horizontal type, centrifugal End Suction
pump of cast iron body & bronze impeller , mechanical seal to ensure a minimum pressure of
4.0 3.5 kg / sq.cm. at highest and farthest outlet at specified flow of 137m3/Hour@70M head No. 1 654882
conforming to IS 1520.The pump shall be coupled to TEFC motor of suitable HP & speed and
complete set shall mounted on common base frame with , coupling, coupling guard,
foundation bolts etc. as required. ( Water Curtain System )
Sr.No. Description Unit QTY. Rate Total Amount
Sr.No. Description Unit QTY. Rate Total Amount
Providing, fixing, testing and commissioning of Jockey Pump 10.8M3/[email protected]
Centrifugal End Suction. he pump shall be coupled to TEFC motor of suitable HP & speed
and complete set shall mounted on common base frame with coupling, coupling guard,
foundation bolts etc. as required
Providing, fixing, testing and commissioning of cubical type floor mounted power cum
control panel complete with suitable switch gear, bus bars, relays, contractors, indicating
lamps, fuses, instruments manual isolator & auxillary switch including connections complete
as required.
Providing, fixing, testing and commissioning of below Cable for Fire Pumps ( Only from
Panel to Pumps)
7.1 3 C X 70 Sqmm Alluminium Armoured Mtr 90 671
7.2 3 C X 16 Sqmm Alluminium Armoured Mtr 60 249
7.3 3 C X 10 Sqmm Alluminium Armoured Mtr 60 227
7.4 2 C X 1.5 Sqmm Copper Armoured. Mtr 450 150
7.5 Cable Tray 300X50 mm. Mtr 30 772
7.6 Cable Tray 150X50 mm. Mtr 40 425
Providing, fixing, testing and commissioning of Pressure Gauge with cock & accessories for
8.0 pumps.The pressure gauge shall be approved type. The Gauges with cock shall be constructed Nos. 10 4253
of die cast aluminium & stove enameled. The Gauge shall be of stainless steel bourden type.
Providing, fixing, testing and commissioning of Pressure switches of diaphram operated
9.0 SPDT type whether IP66 suitable range (15 kg/cm² to 5 kg/cm²) for pump sets with Ball Nos. 7 3780
valves, Fittings like unions / collars / reducers etc.
Providing, fixing, testing and commissioning Air vessel fabricated from 10mm MS plate with
dished ends,dia of 350 mm and height 2000 mm with suitable supporting legs, outside painted
with one coat of primer and two coats of synthetic enamel paint of approved shade, complete
with one 25mm dia connection from pump delivery, one 25 mm drain with valve.The air
vessel shall be tested to 1.5 times of working pressure. Complete as per technical specification
& drawing details.
Providing, fixing, testing and commissioning of Sluice valves as per ( PN 16) slim seal with
required flanges, nuts, bolts etc. complete.
11.1 200mm dia Nos. 8 56778
11.2 150mm dia. Nos. 11 35043
11.3 100mm dia Nos. 2 22822
11.4 80mm dia. Nos. 2 15924
11.5 65mm dia. Nos. 0 12690
Sr.No. Description Unit QTY. Rate Total Amount
Sr.No. Description Unit QTY. Rate Total Amount
11.6 50mm dia. Nos. 3 10418
11.7 25mm dia.Ball Valve. Nos. 6 2821
11.8 15mm dia Ball Valve. Nos. 17 2109
Providing, fixing, testing and commissioning of C.I. Reflux Swing Check Valve/ Non-
12.0 Return Valve as per IS 5312 ,PN 16 rating with fittings, flanges, nutbolts, washers, gaskets
etc.of sizes:
12.1 200mm dia Nos. 1 51979
12.2 150mm dia Nos. 5 29363
12.3 80mm dia No. 2 11186
Providing, fixing, testing and commissioning of heavy duty double flanged flexicon rubber
13.0 expansion joint (suitable for system test pressure) of standard length as per manufacturers
specs including rubber gaskets, flanges, nuts, bolts and washers complete as required.
13.1 200mm dia 5 20453
13.2 150mm dia 5 15195
13.3 100mm dia 2 11835
13.4 80mm dia 2 9865
Providing, fixing, testing and commissioning of Above Ground MS. ERW Black C Class
Heavyduty pipes as per IS: 1239 (upto 150 mm dia.) and IS: 3589 (upto 200 mm dia. And
14.0 above) including cutting, screwing, welding etc. and providing all fittings like flanges, bends,
tees, elbows, reducers, clamps, hangers etc. with painting of one coat of primer and 2 or more
coats of synthetic enamel paint of approved make / shade complete as per specification.
14.1 200mm dia Meter 42 6204
14.2 150mm dia Meter 36 4304
14.3 100mm dia Meter 24 2914
14.4 80mm dia Meter 18 2040
14.5 65mm dia Meter 0 1653
14.6 50mm dia Meter 18 1299
14.7 25mm dia. Meter 12 625
Providing, fixing, testing and commissioning of C.I.flanged "Y" type Strainer with SS
mesh,suitable flanges, nuts, bolts, gaskets etc. complete.
15.1 250mm dia Nos. 0 82340
15.2 200mm dia Nos. 5 54293
15.3 100mm dia Nos. 2 15330
B Fire Hydrant System & Acce.
Sr.No. Description Unit QTY. Rate Total Amount
Sr.No. Description Unit QTY. Rate Total Amount
Providing, fixing, testing and commissioning of Above Ground MS. ERW Black C Class
Heavyduty pipes as per IS: 1239 (upto 150 mm dia.) and IS: 3589 (upto 200 mm dia. And
16.0 above) including cutting, screwing, welding etc. and providing all fittings like flanges, bends,
tees, elbows, reducers, clamps, hangers etc. with painting of one coat of primer and 2 or more
coats of synthetic enamel paint of approved make / shade complete as per specification.
16.1 150mm dia Meter 738 4304
16.2 100mm dia Meter 6 2914
16.3 80mm dia. Meter 257 2040
Providing, fixing, testing and commissioning of Under Ground M.S. ERW Black C Class
Heavyduty pipes as per IS: 1239 (upto 150 mm dia.) and IS: 3589 (upto 200 mm dia. And
above) with IWL/pypecoat, 4mm thickness wrapping and coating and providing all fittings
like flanges, tees, elbow, fasteners with all required.
17.1 150mm dia Meter 66 5044
17.2 100mm dia. Meter 6 3890
17.3 80mm dia. Meter 72 3095
Providing, fixing, testing & commissioning of C.I.Butterfly valve conforming to I.S:13095
class PN 16 rating with Fittings, Flanges, Nutbolts, Washers, Gaskets etc.of size:
18.1 150mm dia Nos. 13 13082
18.2 100mm dia. Nos. 1 7503
18.3 80mm dia No. 1 5688
Providing, fixing, testing and commissioning of C.I. Dual plate type Non-Return Valve class
PN 16 rating with fittings, flanges, nutbolts, washers, gaskets etc.of sizes:
19.1 150mm dia. Nos. 3 29363
19.2 80mm dia. Nos. 1 11186
20.0 Fire Fighting Equipement
Providing, fixing, testing and commissioning of SS Single Headed Oblique Pattern Hydrant
20.1 Landing Valves as per IS: 5290 with 80 mm dia flanged inlet & 63 mm dia female outlet Nos. 33 5670
complete with cap and chain etc.
Providing, fixing, testing and commissioning of SS Branch Pipe with nozzle of 20 mm
20.2 nominal bore outlet suitable to fit with standard instanteneous type 63 mm dia coupling. As Nos. 31 2126
per IS:903.
Providing, fixing, testing and commissioning of 63 mm dia 15m long RRL Hose Pipe with
20.3 mm dia.Type A Male and female Stainless Steel couplings duly binded with GI wire, rivets Nos. 62 4646
etc. conforming to IS 636 as required.
Sr.No. Description Unit QTY. Rate Total Amount
Sr.No. Description Unit QTY. Rate Total Amount
Providing, fixing, testing and commissioning of weather proof standard fire Hose Cabinet
20.4 wall mounting type 18 Guage. (750 x 600 x 250) having Double Opening with M.S. Nos. 31 7403
fabricated stand, necessary locking arrangement by allan key.
Providing, fixing, testing and commissioning of Wall mounting swing type first aid Fire Hose
20.5 Reel with drum, hanging bracket, 36 M x 25 mm dia high pressure hose reel tubing as per Nos. 31 9671
IS:884 with shut nozzle and ball valve and all required accessories.
Providing, fixing, testing and commissioning of 25 mm dia Air Release Valve and Ball
Valve assembly on top of each riser for Air release system.
Providing, fixing, testing and commissioning of CI Four way Fire Brigade Inlet as per IS:
20.7 904 having 63 mm dia inlet with 150 mm dia Butterfly valve blank cap and chain with Nos. 3 18563
necessary fittings, flanges, nutbolts etc.
Providing, fixing, testing and commissioning of CI Two way Fire Brigade Inlet as per IS:
20.8 904 having 63 mm dia inlet with blank cap and chain with 100 mm dia Butterfly valve Nos. 1 11255
necessary fittings, flanges, nutbolts, gasket and all required accessories.
C Automatic Fire Sprinkler System.
Providing, fixing, testing and commissioning of Above Ground MS. ERW Black C Class
Heavyduty pipes as per IS: 1239 (upto 150 mm dia.) and IS: 3589 (upto 200 mm dia. And
21.0 above) including cutting, screwing, welding etc. and providing all fittings like flanges, bends,
tees, elbows, reducers, clamps, hangers etc. with painting of one coat of primer and 2 or more
coats of synthetic enamel paint of approved make / shade complete as per specification.
21.1 150mm dia. Meter 552 4304
21.2 100mm dia. Meter 342 2914
21.3 80mm dia. Meter 432 2040
21.4 65mm dia. Meter 498 1653
21.5 50mm dia Meter 684 1299
21.6 40mm dia. Meter 792 981
21.7 25mm dia. Meter 3450 625
Providing, fixing, testing and commissioning of Under Ground M.S. ERW Black C Class
Heavyduty pipes as per IS: 1239 (upto 150 mm dia.) and IS: 3589 (upto 200 mm dia. And
above) with IWL/pypecoat, 4mm thickness wrapping and coating and providing all fittings
like flanges, tees, elbow, fasteners with all required.
22.1 150mm dia. Meter 12 5044
Providing, fixing, testing & commissioning of C.I.Butterfly valve conforming to IS:13095
class PN 16 rating with Fittings, Flanges, Nutbolts, Washers, Gaskets etc.of size:
23.1 150mm dia. Nos. 21 13082
Sr.No. Description Unit QTY. Rate Total Amount
Sr.No. Description Unit QTY. Rate Total Amount
23.2 100mm dia. Nos. 3 7503
23.3 80mm dia. Nos. 0 5688
23.4 50mm dia. Nos. 0 4406
Sprinkler System Equipements.
Providing, fixing, testing & commissioning of Sprinkler Alarm valve of Duct iron body and
brass/bronze working parts comprising of water motor alarm, bronze seat clapper, and
clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the
sprinkler system activates, pressure guages, emergancy releases, strainer, pressure switch, cock
valve complete with drain valve and bypass, test control box, ball valves, flanges, gasket etc.
150mm dia.
Providing and fixing, testing and commissioning of conventional quartzoid bulb type
25.0 Sprinkler with screwed end connection. Sprinklers shall be UL Listed / FM approved with
Chrome finish. ( Quoted for standard response).
25.1 Pendent sprinkler K-80, 68 deg. C Nos. 1491 449
25.2 Upright sprinkler K-80, 68 deg. C Nos. 495 449
25.3 Side wall sprinklerK-80, 68 deg. C Nos. 2 551
25.4 Pendent sprinkler K-80, 79 deg. C Nos. 1 551
25.5 Upright sprinkler K-80, 79 deg. C Nos. 1 551
Providing, fixing, testing and commissioning of SS Flexible drops 1200mm Long. Unbraided
, Maximumm Service pressure 175PSI,.Sprinkler Flexible Drop system is a ready to use
assembly to fit sprinkler heads in desired location in a suspended ceiling. It easily positions
the sprinkler in center of the ceiling tile at a correct height.
Providing, fixing, testing and commissioning of Flow Indicating Switch with fittings,
Flanges, nut-bolts, washers etc. as per requirement of sizes.
27.1 150mm dia. Nos. 9 7536
27.2 80mm dia. Nos. 3 7536
Providing, fixing, testing and commissioning of Annunciator panel for flow control switch,
providing Audio/Visual indicating of actuation of automatic sprinkler system for each zone
complete as per specifications with provision for 12 zones 'Indication of zone fire, 'Indication
of zone fault, 'Fire/Fault hooter, 'Alarm cancel for fire/fault, 'Battery for emergency
Supplying, Installation, Testing and commissioning of 2 C X 1.5 Sqmm Copper Armoured
29.0 Meter 3000 145
for Flow Switch Cabling from Announciation panel to Flow Switch.
Providing and fixing, testing and commissioning of Drainning & Testing Assembly 25mm
dia with by pass valve, drain connection & Sight Glass as required.
Sr.No. Description Unit QTY. Rate Total Amount
Sr.No. Description Unit QTY. Rate Total Amount
D Fire Water Curtain System.
Providing, fixing, testing and commissioning of Above Ground MS. ERW Black C Class
Heavyduty pipes as per IS: 1239 (upto 150 mm dia.) and IS: 3589 (upto 200 mm dia. And
31.0 above) including cutting, screwing, welding etc. and providing all fittings like flanges, bends,
tees, elbows, reducers, clamps, hangers etc. with painting of one coat of primer and 2 or more
coats of synthetic enamel paint of approved make / shade complete as per specification.
31.1 150mm dia. Meter 60 4304
31.2 100mm dia. Meter 216 2914
31.3 80mm dia. Meter 0 2040
Providing, fixing, testing and commissioning of Under Ground M.S. ERW Black C Class
Heavyduty pipes as per IS: 1239 (upto 150 mm dia.) and IS: 3589 (upto 200 mm dia. And
above) with IWL/pypecoat, 4mm thickness wrapping and coating and providing all fittings
like flanges, tees, elbow, fasteners with all required.
32.1 150mm dia. Meter 12 5044
Supplying, Installing, testing and commissioning of UL Listed Deluge valve,
Horizontal/Vertical mounting, Ductile Iron body, Aluminium bronze Clapper and Latch,
EPDM Clapper seal, Nitrile rubber bushing and seat O ring, S.S Shaft and EPDM diaphragm
complete with Electrical Release trim, Hydraulic Release trim, Pressure Switch, Solenoid
valve actuator and Control Panel including necessary accessories, complete with tap off
socket arrangement as required, with potential free contact with 2 Nos. NO/NC & ON/OFF
arrangement and all other associated works of complete as required..
(Rates quoted without wiring).
Note: The Integration of deluge valve / Drencher system with Fire Alarm System shall be
carried out by Fire Alarm System Contractor.
33.1 100mm dia. No. 2 84476
Providing & fixing UL listed, FM approved Open Nozzels for Drencher / Water Curtain
application for protection of vertical openings against fire exposure or penetration. Nozzle
shall be Brass Body suitable for Minimum 07 psi and Maximum 175 psi working pressure,
with 1/2" thread size K factor
Providing, fixing, testing & commissioning of C.I.Butterfly valve conforming to IS:13095
class PN 16 rating with Fittings, Flanges, Nutbolts, Washers, Gaskets etc.of size:
35.1 100mm dia. Nos. 6 7503
35.2 80mm dia. Nos. 0 5688
Sr.No. Description Unit QTY. Rate Total Amount
Sr.No. Description Unit QTY. Rate Total Amount
Supplying, Installing, testing and commissioning of Local Control Panel for Deluge Valve
36.0 Auto Operation with necessary Cabling and including of Solenoid valve. (Solenoid Valve Nos. 2 28350
integration with Fire Alarm Panel will be in Fire Alarm System Contractor.)
37.0 Fire Extinguishers
Providing & fixing of ABC 6 Kg Fire Extinguisher Mono Ammonium Phosphate Powder
37.1 Stored Pressure Type, Pressure Gauge, Controllable discharge mechanism Class A Rating 3A Nos. 71 2160
& Class B rating 21B as per IS
Providing and fixing, testing and commissioning of CO2 type Fire Extinguisher of capacity
4.5 kg filled with Co2 Gas as per IS 15222 with controll discharge mechanis, fitted with Hose
& Horn applicable on Class B fire rating 21B confirms to IS 15683 bearing ISI mark. Co2
cylinder as per IS 7285 .
Providing and fixing, testing and commissioning of Higher capacity Trolley mounted ABC
37.3 Dry Chemical; Powder type ( MAP - 90% ) Fire Extinguisher of capacity 25 kg. confirms to Nos. 3 8690
IS 10658, bearing ISI mark, ( Outside Co2 Cylinder 1 Kgs. Cap )
Providing and fixing, testing and commissioning of CO2 type Fire Extinguisher of capacity
22.5 kg filled with Co2 Gas as per IS 15222 with controll discharge mechanism fitted with
Hose, Horn & TROLLEY confirms to IS 2878 bearing ISI mark. Co2 Cylinder as per IS
Providing and fixing, testing and commissioning of Higher capacity Trolley mounted
37.5 Mechanical Foam type Fire Extinguisher of Capacity 50 liter confirms to IS 13386, bearing Nos. 5 11403
ISI mark, (Quoted For 45 ltr)
38.0 Providing, fixing, testing and commissioning of below Auto Glow Signages.
38.1 Emergency Exit (4"X12") Nos. 29 460
38.2 Fire extinguishers (8"X12") Nos. 71 762
38.3 Fire Lift (4"X12") Nos. 8 460
38.4 In case of fire do not use lift, use staircases (8"X8") Nos. 8 561
38.5 Fire Fighting Equipment's. (8"X12") Nos. 20 762
39.0 Civil Work. (In Client Scope)
39.1 Providing, fixing, testing and commissioning Hume Pipe NP2 class 400mm dia. Meter 20 1490
39.2 valve camber. 1M X 1M X 1M. Nos. 1 94500
39.3 Excavation & Backfilling Of Soft And Hard soil. Cu.Mtr 200 788
40.0 Supply, Installaton of Structure Steel Support KG 3500 130
Sr.No. Description Unit QTY. Rate Total Amount
Sr.No. Description Unit QTY. Rate Total Amount
fire rated steel doors with steel frames as per BS:476 (20&22), IS 3614 (Part-2) for stability
and integrity. pressed Galvanized steel conforming to IS 277 with the following specification.
recommended fire door shell have doors tested at CBRI for maximum rating of 120 Minutes.
Door frame shall be Single rebate profile of size 105 x 57 mm made out of 1.60mm (16gauge)
minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self-
tabs. All provision should be mortised, drilled and tapped for receiving appropriate hardware.
Rubber door silencers should be provided on the striking jamb. Frames should be provided
with back plate bracket and anchor fasteners for installation on a finished plastered masonry
wall opening. Once frame installed should be grouted with cement & sand slurry necessary for
fire doors on the clear masonry opening.
Door leaf shall be 46mm thick fully flush double skin door. Door leaf shall be manufactured
41.0 from 1.2mm (18guage) minimum thick galvanized steel sheet. The internal construction of the Sqmtr
door should be rigid reinforcement pads for receiving appropriate hardware. The infill
material shall be resin bonded honeycomb core. All doors shall be factory prepped for
receiving appropriate hardware and provided with necessary reinforcement for hinges, locks,
and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of
doors astragals has to be provided on the meeting stile for both active and inactive leaf. Vision
lite wherever applicable should be provided as per manufacturer's recommendation with a
beading and screws from inside. The glass should be 6mm clear borosilicate fire rated glass of
relevant rating of the door.
All doors and frames shall be finished with polyurethane aliphatic grade paint of approved
color. The door leaf and frame shall have passed minimum 250 hours of salt spray test. Rate
should include supply and installation of door and hardware set as mentioned in the door.
APPROVAL Fittings
FIREMake :- Doorma
SYSTEM FROM, Geze , Hafales
LOCAL FIRE AUTHORITY
42.0 Getting of Fire Fighting System Approval from local fire authority with all other charges and Job. 1 350000
documentations for getting No Objection Certificate.
TOTAL AMOUNT ₹
TOTAL AMOUNT ₹
AHMEDABAD MUNICIPAL CORPORATION
Construction of Auditorium At TP No 124C, FP No 31 (Social Infrastructure), in Thhakarnagar Ward, North Zone, Ahmedabad.
BOQ for Interior Work
Sr. No. Description Total Qty Unit Rate Amount
Acoustic Wall Paneling Below 2.40m Height :-
Supply & installation of Anutone Slats Surco Plus,made of pinewood E1 grade fiberboard, melamine finish, groove perforated slats L8-2 - (2mm
grooves @ 8mm centers with 5.5% open area) / L16-2 - (2mm grooves @16mm pitch with 7.3% open area) / L32-2 - (2mm grooves @ 32mm
centers with 3.7% open area) / L64-2 - (2mm grooves @ 64mm centers with 1.8% open area), backlined with Soundtexblack acoustical fleece of
0.27mm thick, surface density 63g/m2,tongue-groove edge for a seamless look, 5-test fire retardant grade, size 128 x2440x16mm, volume density
of base board 700Kg/m3, weight 9Kg/m2 (L16), 10.5Kg/m2 (L32), 11Kg/m2 (L64) installed by using Anutone Strut framework system. The
Anutone Strut framework system shall include Anutone Strut CC10 thickness 0.55mm, length 3600mm, knurled web 40mm, depth 10mm and
equal flanges of 15mm is fastened to the wall positioned horizontally/vertically at every 600mm centres. Anutone Strut CC18,aluminium core cross
channel, thickness 0.5mm, length 2400mm, web 15mm & 27mm, depth 18mm and flanges of 7mm with suitable edge & center brackets is then
1 fixed perpendicular to the Strut CC10 with the help of fasteners at every 400mm centers Anutone Slats Surco Plus of size 128x 2440x16mm in then 357.00 Sqm 8,271.00
fixed perpendicular to Strut CC18 with suitable edge & ccentre brackets. Contractor to provide expansion joints of 3mm at every 4.88m length
wise and 4.992m width wise. The system is backlined with Anutone SynthPF 10x10 held in position with dab spots of Anutone stick S7/wire mesh
(not by Anutone).
Technical Parameters
• Fire (Class) – A
• Acoustics – NRC upto
• Climate (°C, RH) – 50,
• Light reflectance (%) – 75 (Maple Arce)
• Green (VOC, RC %) – E1,
Sr. No. Description Total Qty Unit Rate Amount
Acoustic Wall Paneling Above 2.40m Height :-
Supply and installation of Anutone or equivalent Stretch NRC system consisting of FR Grade NRC fabric with high-performance Polypropylene
core and acoustically-transparent face covering of choice colour, size 1.7m x 75m, stretched by using combination of Anutone or equivalent
Strand2 primer 600 x 1200 x 15mm, Anutone or equivalent Strut FS15 Tracks, Anutone or equivalent Synth PF 10 x 25 infill with Anutone or
equivalent strut framework. The Anutone or equivalent Strut framework system shall include Anutone or equivalent Strut CC25, fully knurled,
sectional thickness 0.55mm, length 3600mm, knurled web 50mm, depth 25mm and equal flanges 15mm is fastened to wall horizontally at 600mm
centers. Anutone or equivalent Strand2 primer panels of size 600x1200x15mm, density 400kg/m3, weight 6kg/m2 are then fastened perpendicular
to strut CC25 behind using suitable fasteners. Wooden/ply base 10mm are then installed on Strand2 primer on marked lines with metal fasteners at
300mm centers embedded in plastic sleeves. Fix Anutone Strut FS15 half wrap , Midseam and Outer corner, rigid FR-PVC high strength tracks
square / bevel edge on the wooden surface by using heavy-duty fasteners at 150mm centers on one/both sides of Anutone or equivalent Strut
2 Tracks. Anutone or equivalent Synth PF 10 x 25mm is then adhered on Strand2 primer,inbetween tracks, using Stick 7 adhesive. This completes 1,214.00 Sqm 8,392.00
the substrate to receive the Stretch NRC acoustical membrane. The Anutone or equivalent Stretch NRC acoustical fabric of width 1.7m is stretched
and tucked into the Anutone or equivalent Strut Tracks and secured to the locking jaws with purpose-specific tucking tools to obtain smooth, taut,
wrinkle-free finish. Ensure the weft and weave of the fabric along with the surface all oriented in one direction to achieve uniform shade. Note:
Minimum 100mm additional fabric is required for tucking hence maximum module wall fabric width would be 1600mm.
Technical Parameters of finish product
• Fire (Class) –
• Acoustics – NRC upto 0.7 (for system)
• Climate (°C, RH) – 50,
• Light (%) – colour dependent
• Green (VoC, RC %) – Low,
Auditorium False Ceilng :-
Supply and Installation of Conceil-A edge,Glassfibre core fully encapsulated ceiling tile of size 600x1200x20mm having volume density
120Kgs/m3, weight 2.4kg/m2 suspended using 0.3mm thick Anutone Skelet Trelis T24 metal grid system.
Skelet TrelisT24 framework system includes Skelet WA24W30,sectional thickness 0.4mm, wall angle with equal flanges of 24mm, length
3000mm, fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centers.
Then suspend the Skelet MT24W36, sectional thickness 0.3mm, with flange width 24mm, height 38mm and length 3600mm, from the soffit slab
with help of soffit cleat and wire rod with leveling clip at 590mm centres. Extra support to be added near jointing of two MT24 so that end
cantilever should not be more than 150mm.
Strut M6 threaded rod is then positioned in the slots on top of web of Main T24 at 1200mm centers in staggered pattern to hold system in
position.M6 threaded rods to be secured in place with M6 hexagonal nuts.
Anutone Subtex Nubby, ConceilA edge, of size 600x1200x20mm shall then be slided onto Main T24 such that short edges are staggered.
Technical Parameters :
• Fire (Class) – 1 & P
• Acoustics – NRC 0.9 (For E900 Mounting)
• Thermal conductivity (W/mk)–
• Climate (°C, RH) – 40,
• Light reflectance (%) –
• Green (VoC, RC %) – Low,
Sr. No. Description Total Qty Unit Rate Amount
Plain Auditorium False Ceiling :-
Providing & laying M/F Suspended single layer of 12.5 mm tapered edge Gypsum Board ceiling , which includes metal frame work with using
CS55, IC91, PC55, CA55 CRP surface ribbed perimeter channels with the help of nylon sleeves and screws at 610 mm centres along the perimeter
of ceiling. Then ecotone ultraribbed intermediate channels of size 45 mm from the soffit at 1220 mm centres with Ecotone ultra™ CRP surface
ribbed ceiling angle fixed to soffit with cleat and steel expansion fasteners. Then Ecotone ultra™ CRP surface ribbed Ceiling section are then
fixed to the Ecotone ultra™ intermediate channel with the help of connecting clip and in direction perpendicular to the Ecotone ultra™
intermediate channel at 457.5mm centres. Single layer of 12.5mm Gypsum boards are then screw fixed to ceiling section with 25 mm drywall
4 screws at 230mm centres. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes 3,480.00 Sqm 1,093.00
filling and finishing with Jointing compound, Joint Paper tape. Rates shall be inclusive of cost of making cut outs/openings for electrical fixtures,
tube lights / air-conditioners grills, diffusers etc. & providing additional sections for strengthening the openings/cutouts, making grooves between
wall & board or as per drawing / instruction of EIC. Area of cutouts shall not be deducted and no extra payment shall be considered for additional
sections provided . The rate shall be in sq.mt. for all floors and at all heights including all costs. The rates are also inclusive of necessary
scaffolding, tools, tackles etc. The shop drawing (or a sample mock of 5 sqm minimum of the frame work and ceiling) shall be approved from EIC.
with all material and labor but excluding paint.
(Make:- Gyproc / Ecotone / USG Boral / P steel)
LOOP PILE CARPETS :-
Supply & installation of 100% commercial grade nylon carpet tile of 500x500mm of solution dyed nylon 6 quality ,Machine Gauge 1/10” or more
and having properties of Soil Guard or more, total height of 6 to 8 mm, smoke density( ASTM E 662) less than 450, anti static less than 1.0kv,
5 electrostatic propensity – maximum average 0.5kv (AATCC 134) Color fastness to light- rating 5.0= No change (AATCC 16) critical Radiant flux 1,887.00 Sqm 2,908.00
–(ASTM E 648) Class 1 average CRF 0.48 / cm2 or approved equivalent. including all accessories, material & labor complete as directed by
Architect / Engineer – in – charge.
(Make:-Unitex/Flotex/Melody )
Acoustic Door :-
Providing & fixing of teakwood door frame of section 150 x 65mm along with fire and smoke in tumescent seal strip of size 12mmx4mm for
minutes fire rated and rw 35db acoustic door with minimum thickness of 93mm having infill of 50mm thick Knauf make glass wool of 48kg/m3
density sandwiched by two 12mm thick magnesium board (edge to edge on internal hardwood frame)and cladded with 6mm thick commercial ply
6 facing and 3mm sheet rubber interlayer And finished with 1mm thick laminate as per designer and 25mm thick teakwood frame around the door 31.00 Sqm 15,525.00
panel as shown in the drawing. The board shall be resistant to vermin, mold growth, minor impact, abrasion and short term water attack and shall
be in color as approved by the designer, the door shall have acoustic seal in door rebates and drop dead seal at the bottom of the door, the sound
reducing doors also include door closer, door coordinator, panic bar with outside key and handle etc.
(Make:- Ecotone / Off / Sound Easy)
Auditorium Chair :
Supply and Fixing of Auditorium seating preferably TSI Brand – SOLIUM D4 MODEL or equivalent make approved by the Architect. Fabricate
Auditorium seating with Auto Tip Up, Synchronized Push back by help of 16 ball and 4 rollers Automobile type robust sliding system, CO2 MIG
welded Tubular Powder Coated Seat and Back frame from Dia 22.23 ERW CRCA tube, Chair with PU padding with 3 Layer 100% Yarn Dyed
fabric Upholsteries with injection-moulded seat and back Plastic covers. Equip each seat with a self-rising Torsion Spring compensating
mechanism so that unoccupied seats return to an upright position perpendicular to the base line of floor of auditorium. Chair profile with the seat in
the upright position and without a tablet arm, The Seat Size should be 45 cm x 45 cm & the Back size should be 45 cm x 66 cm with ergonomically
designed seat and back cushions. Chair should be available in 21” and 22” to use multiple seat size in one layout for matching variable arch length.
Sr. No. Description Total Qty Unit Rate Amount
Supply and Fixing of Two Seater Sofa Complying with specifications mentioned below :
Inner Structure: The inner structure should be made up of Solid Pine Wood section of 2” x 1.5”. Dully Fixed together with Double Nailed Pins of
2” long by Specialized Crack prevention tools. The entire assembly should be sturdy and play free. The two Side profile section must be made out
of CNC Machined Panels with Thickness of 1.2 cm High Compressed plywood in single piece profile. The plywood must be at lease made up of
8 IS 303 Grade plywood. The Sofa must have High Resiliency Cushioning material to achieve upmost comfort and durability. Product should consist 20.00 Nos. 19,527.00
of multi Layer Poly Urethane Foam fabricated to size and shape required by architect in different density as per design and comfort requirement
from 32 kgf/m3 Density to 42 kgf/m3 Density in layer to layer manner as per industry standards. Sofa upholstery must be supplied as per
Featherlite
Stage Wood Frame Work :-
Providing and fixing Hard wood such as merandy wood scanting of 150 x 75 mm and cross of 100 x 75 mm size in base frame work for two layes
of stage flooring. The Merandy wood shall be of approoved quality (kiln seasoned upto 8 to 9 % moisture content & treated with chemical
9 treatment scanting shall be placed at require distance and rigidly fixed position with cemented Merandy wooden gutties and M.S. screws at 600 5.00 Cum 1,35,262.00
mm c/c. in each direction / member. The frame work shall be inter connected in approved manner at the junctions including planning the top and
painting the wood work. with twocoats ofblack japan paint all around etc. complete with necessary scaffolding the work shall have to be carried
out by Architect and as specified including all accessories, material & labour complete as directed by Architect / Engineer – in – charge.
Stage Wood Plank Flooring :-
Providing and fixing 150 x 37 mm (6"x 11/2" out of) secret T & G (as per detail given by consult scientific kiln drying to under 8 to 9 % moisture
content, Merandy wood plank (free from knot, warp and bend etc.) as per drawing and insturctions stated below etc. by Architect and as specified
including all accessories, material & labor complete as directed by Architect / Engineer.
(a) Complete lot of Indian Teak plank shall have scientific kiln drying up to 8 to 9% moisutre content, teak plank (free from knot, warp and bend
etc) as per Architect and as specified including all accessories, material & labor complete as directed by Architect / Engineer.
(b) Anit termite treatment to interanl wood surface of plank bu Aldrex or equivalent complete with scaffolding, leveling, sanding etc.as per
Architect and as specified including all accessories, material & labour complete as directed by Architect / Engineer – in – charge.
Sand Filing :-
11 Providing and fixing EXTRA 250mm thick layer of washed river sand free from dirt, inspect in between wooden frame complete by Architect 53.00 Cum 18,320.00
including all accessories, material & labor complete as directed by Architect / Engineer – in – charge.
Stage Wooden Flooring :-
12 Provinding and Laying 15 mm thick enginering Stage woodan Flooring shapherd / unitex make laminated wooden flooring on top of foam layer 241.00 Sqm 7,789.00
over a base of wooden plank flooring including all accessories, material & labor complete as directed by Architect / Engineer – in – charge.
Main Curtain :-
Providing & supplying including stitching ecotone or equivalent make decorative main curtain, vertically up down slider in art silk, velvet fabric of
approved shade and quality. The curtain shall have 100% gathering cloth complete with bottom silk thread lace and same colour grout up to room
height. The curtain shall be with vertical sliding arrangement complete with fixing rails, brackets, sliding arrangement & motorized operation
13 complete with runners, master runners, pullies, 6mm to 8 mm steel wire rope, 1.5 HP three face motor. Air breaker contractors, micro switches for 1.00 Nos. 8,54,557.00
auto stop, push button remote control for forward, reverse and stop positions. The curtain should be vertically up down with maximum gathering
position. Hamming and bottom finishing at site etc. complete as directed by E.I.C. / Architect of the project.
Providing & fixing 35 mm dia. road for curtain control equipment with necessary M.S. flat support from ceiling with scaffolding, leveling,
necessary M.S. bracket including all accessories, material & labor complete as directed by Architect / Engineer – in – charge.
Sr. No. Description Total Qty Unit Rate Amount
Rear Curtain :-
Providing & Supplying including stiching decorative main curtain in glazed cotton fabric of approved shade and quality. The curtain shall have
50% gathering cloth complete with botton silk thread lace and same colour grout up to room height. The curtain shall be with horizontal sliding
14 arrangement complete with fixing rails, brackets, sliding arrangement & motorised operation complete with runners, master runners, pullies, 6mm 1.00 Nos. 6,30,463.00
to 8mm steel wire rope, 1HP motor (crompton) 2nos. Air breaker contractors (L&T / SIEMENS) 2nos. micro switchs for auto stop, 3nos. push
buttons for forward, reverse and stop positions. The curtain should be draped to half area when in closed position. Minimum overlap at center
should be 900mm. Hamming and bottom finishing at site etc.
Center Curtain :-
Providing & Supplying including stiching decorative main curtain in glazed cotton fabric of approved shade and quality. The curtain shall have
100% gathering cloth complete with botton silk thread lace and same colour grout up to room height. The curtain shall be with horizontal sliding
arrangement complete with fixing rails, brackets, sliding arrangement & motorised operation complete with runners, master runners, pullies, 6mm
to 8mm steel wire rope, 1.5 HP motor (crompton) 2nos. Air breaker contractors (L&T / SIEMENS) 2nos. micro switchs for auto stop, 3nos. push
buttons for forward, reverse and stop positions. The curtain should be draped to half area when in closed position. Minimum overlap at center
15 should be 900mm. Hamming and bottom finishing at site etc. 1.00 Nos. 6,52,935.00
(a) Providing & Supplying including stiching decorative main curtain in glazed cotton fabric of approved shade and quality. The curtain shall have
50% gathering cloth including bottom silk fringe of same colour or as approved with brass hook suspension etc. complete as directed by E.I.C /
Architect of the project.
(b) Providing / Fixing 25mm thk. Hard wood platform for curtain control equipment with necessary M.S. flat support from ceiling as per drawing
shown by manufacturer. complete with scaffolding, levelling necessary M.S. Brachet with red oxide paint et. including all accessories, material &
labour complete as directed by Architect / Enginner - in - charge. Opening Size :- 22.51 x 9.25 m
Cycloram Curtain :-
Providing & Fixing cyclorama curtain cum screen in plastic perforated material. The screen to be fixed on tubular frame made out of 35mm dia MS
pipe. Pipe shall be finished with red oxide paint and black color oil paint, including all accessories, material & labour complete as directed by
Architect / Engineer - in - charge.
Providing & supplying including stitching Ecotone or equivalent decorative pelmet in Art silk velvet fabric of approved shade & quality. The
17 pelmet shall have 50% gathering cloth including bottom silk fringe of same colour or as approved with brass hook suspension with Design and 25.00 Rmt 1,326.00
writing as per your requirement etc. including all accessories, material & labor complete as directed by Architect / Engineer – in – charge.
Height of Pelmet should be minimum 1.5mt.
Providing & Fixing wings (sliding partition) made out of black / blue glazed cotton cloth (FR) with fixed of MS 50 mm x 25 mm x 16G mspipe
welded frame work. The pipe framework made out of 25 mm x 50 mm pipe. c/c 900 mm x 900 mm fixed with overhead pivote track and bottom
channel etc. complete with duly painted on both framework.
Size : 3000 mm x 9000 mm Customized
(b) Above frame shalll be covered by blue/black FR colour glazed cotton fabric by black nailing.
(c) Top member have sliding fitting in aluminium channel & bearing wheel or in M.S channel etc. including all accessories, material & labor
complete as directed by Architect / Engineer – in – charge.
Proscenium :-
Providing & Fixing proscenium made out of MS 50 mm x 50 mm x 16G mspipe wielded frame work. The pipe framework made out of 50mm x
19 50 mm pipe. c/c 600 mm x 1200 mm fixed with overhead track and fixing 12 mm ply / 15 mm duraline board both side complete with duly painted 138.00 Sqm 4,300.00
on both framework.
Customized including all accessories, material & labor complete as directed by Architect / Engineer – in – charge.
Sr. No. Description Total Qty Unit Rate Amount
Providing & supplying including stitching glazed cotton colour fabric drop (frill) above the stage. The drop shall have 50% gathering cloth the
curtain is to be suspended from G.I. Pipe with string and hooks etc.
(a) Providing / Supplying / Fixing 'B' Class 50 mm dia. Gi Pipe for curtain / frills, suspension as per drawing shown complete with bend coupling,
socket, nut bolt scaffolding if require weldung with one coat of red oxide with nails etc. at site including all accessories, material & labour
complete as directed by Architect / Engineer - in - charge.
Mirror Panelling (Green Room) :-
Providing and Fixing Mirror with surrounding Box for Fixing of Bulb in VIP, Ledis and Gents Green Room Box made from 18mm thk. Water
proof Plywood on Wall for approved quality of Mirror, all around box for lighting made with 18mm thk. Water Proof Plywood finished with
Laminate and open edge cover with bedding / moulding patti and finished with polish. Size of 1.50 mt x 2.44 mt.
Green Room Table :-
Providing and Fixing Table with 18 mm Plywood Size of Table 1.50 x 0.600 m in VIP, Ladies and Gents Green Room. Making Of Table With
Drawers On Each Table With Using 20 Inch Channels On Drawers With Two Supporting Sides As Per Drawing, Inside And Outside Covered
With Laminate As Per Design Approvel and open edge cover with bedding / moulding patti and finished with polish. With labour and all.
Table 750 x 750 x 1000 mm The scope includes supply and erection / installation of the item on site the table area of 19 mm thick BWP plywood.
23 The top surface is finished with high pressure laminate of 1 mm thick the edges of all surfaces with teak wood beading the thickness of top and 2.00 Nos. 18,975.00
legswith 40mm, 1 Nos. keyboard tray with powder coated, modesty Pamel : 1 mm thick laminate on 19 mm thick BWP Playwood, The rate
including labour, All small Attachment and necessary item required to complete the job. as Per Instruction of Engineer in Charge.
Revolving Chair :-
per instruction as directed by site in-charge or architect.
Providing & constructing two seater sofa made up of salwood framework upholstered with 32 density mm foam, covered with thin sponge and
muslin cloth and furnished in composite leather of approved shade as per drawing & approvals.
Providing and installing Elite Series Fabric Roller Blind with control unit complete with all hardwares. The Fabric will allow no passage of light
and comes with PU coating which has control over light. The Fabric is made of 100% polyester woven fabric. The thickness is 0.4 mm and
openness factor is 0% light transmission. Weight of the fabric is 450 grams/ sq. mtr with tolerance of 10%. The density of the fabric is 72/in x
/in. The fabric comes in variety of shades and to be finalized as per instruction of Architect in charge.
Providing and fixing AMC logo on SS eatching plate as per following specifications. SS matt finish 304 grade 1 mm thk plate. All sign will have
text in english and color of text as approved by Architect / Client. Size 1200mm dia.
28 Providing and Fixing of AMC TEXT in gujarati letters with use of SS Material including fixing of the same at proper place (600 MM hight). 1.00 Nos. 1,25,023.00
29 Providing and fixing 4 mm thk Mirror glass with studs. 70.00 Sqm 2,896.00
30 Providing and Fixing Film on Glass as per requirement. 34.00 Sqm 1,346.00
31 Providing & fixing 12mm Clear Toughened Glass including fitting with Hole and Fixing with SS Studs in SS Railing. 152.00 Sqm 8,133.00
Providing and fixing Signages made from S.S. 304 in 1 mm thick SS plate with eateching as per design and filling the black or any color as per
32 requirnmnet of architects with any size with fitting and Including all accessories, material & labor complete as directed by Architect / Engineer – in 13,000.00 Sq. In. 53.00
– charge.
Total Amount
Total Amount
AHMEDABAD MUNICIPAL CORPORATION
Construction of Auditorium At TP No 124C, FP No 31 (Social Infrastructure), in Thhakarnagar Ward, North Zone, Ahmedabad.
BOQ for Garden & Landscaping Work
Sr. No. Total Qty Description of Work Unit Rate Amount
lawn for 3 months or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying
farm clay up 300 mm thick, sludge, manure, pesticides, extra earth, disposal of rubbish, trench excavation and all
labour with lead and lift etc. complete as directed by EIC.
Providing & construction Tree plants required Digging of pits 0.6mt. x 0.6mt x 0.6mt, filling with goodearth with
mixing of cow dong and pesticide.planting the following plant of 4' to 6' height stack it well, maintain it for 3 month
name of plants Neem, Nagor, Avonla, Aritha, Garmala, Neem, Nagor, Avonla, Aritha, Garmala, Neem, Nagor,
Avonla, Aritha, Garmala etc. completed as dircted by E.I.C/PMC.
Ayurvedic shrubbery Clinning the bed, mixing of the fertilizer and pesticides, digging the pit planting the good
quality of plant at required distance, maintain it for 3 month name of plants Tulsi, Brahmi, Aloe vera, Ardusi,
Asparagus, Panputti, Nagar vel, Phudina, Ashwagandha, Gugal, Wedellia, Jecomentia, Umbrella palm, etc completed
as dircted by E.I.C/PMC.
Planting of exoitic palm trees Digging of pits 0.6mt. x 0.6mt x 0.6mt, filling with good earth with mixing of cow
dong and pesticide.planting the following plant of 8' to 10' height stack it well, maintain it for 3 month Bottle palm,
Coconut, Sopari, Fish tail, Fox tail, Phonix, Date palm, Bismarkia, Shampagon, Latania,etc completed as dircted by
E.I.C/PMC.
Planting of Ornamental shurbs Digging of pits 0.6mt. x 0.6mt x 0.6mt, filling with good earth with mixing of cow
dong and pesticide.planting the following plant of 8' to 10' height stack it well, maintain it for 3 month Golden
bamboo, Green bamboo, Ficus spp.Ixora spp., Hibiscus spp., Allamanda spp.Bougainvella spp., Nerium spp,
Plumeria spp. etc completed as dircted by E.I.C/PMC.
6 935.00 Providing pesticides ,dust as directed by architect engineer incharge. KG 80.00
7 198.00 Providing pesticides ,liquid as directed by architect engineer incharge. Liter. 595.00
8 110.00 Providing and Supplying fine river silt (Kamp) as directed by EIC. Cum 550.00
Sr. No. Total Qty Description of Work Unit Rate Amount
Providing and fixing M.S. flat iron tree guard 60 cm dia and 2 m hight, above ground consisting 4 nos 25 x 6 mm,
2.25 m long and 8 nos 25 x 3 mm 2 m long verticals M.S. flats, riveted to 3 nos 25 x 6mm M.S. flat iron rings in two
halves, fixing together at site withrequired six numbers of 8 mm dia. and 30 mm long bolts, including painting two
coats with synthetic enamel paint of approved brandand manufacture over a coat of primer. One name plate of
mmthick M.S. sheet of size 250x100 mm shall be welded to the treeguard near the middle height and lettered PIU/
any other approved name. The tree guard shall be suitably fixed to the groundby embedding four legs of tree guard in
pits of suitable dia and to adepth of 25 cm, refilling the pits with soil and ramming, complete inall respect as per
satisfaction and direction of Officer-in-charge.etc completed as dircted by E.I.C/PMC.
TOTAL AMOUNT
TOTAL AMOUNT
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
BASEMENT-1 PLAN.pdf
BASEMENT-2 PLAN.pdf
FIRST FLOOR PLAN.pdf
SERVICE FLOOR PLAN.pdf
UPPER TERRACE FLOOR PLAN.pdf
Volume - II Technical Specifications (1).pdf
ELEVATIONS And SECTION.pdf
SITE LAYOUT And GROUND FLOOR PLAN.pdf
Volume -I Technical Bid.pdf
Volume - III Financial Bid.pdf
Download all tender documents and submit your bid