| 1 | L1₹23.6 LAccepted-AOC NAYA BASS MAHAMANDIR JODHPUR RAJASTHAN 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L1 | Accepted-AOC LOWEST REASONABLE BID | |
| 2 | L2₹26.1 L+₹36,390 (1.41%)Rejected-Finance SHOP NO 13 MOHINI MARKET KISHORE BAGH MANDORE JODHPUR RAJ | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹26.7 L+₹1.0 L (3.91%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹27.3 L+₹1.6 L (6.31%)Rejected-Finance SPECIAL 1 INDUSTRIAL ESTATE NEW POWER HOUSE ROAD JODHPUR 342003 | JODHPUR | RAJASTHAN | 342003 | L4 | Rejected-Finance NOT LOWEST |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
9 Mar 2023, 6:00 pmClosed
CWE ARMY JODHPUR
CWE ARMY MULTAN LINE ARMY AREA JODHPUR-342010
MAINT/REPAIR OF EXTERNAL ELECTRIFICATION ITEMS LIKE HT CONDUCTOR, HT PANELS, TRANSFORMERS AND ALLIED ITEMS AT ARMY AREA BANAR JODHPUR UNDER GE BANAR
2023_MES_579774_1
82223/97/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BANAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE BANAR
₹60,000
Yes
28 Apr 2023
8 Feb 2023
13 Mar 2023
8 Feb 2023
9 Mar 2023
23 Feb 2023
9 Feb 2023 - 22 Feb 2023
Amount
Disconnecting electric outdoor/indoor transformer 11 KV capacity up to 500 KVA from HT/LT terminals and lowering down/getting out from 2/4 pole structure/plinth or from inside sub station for major/Minor repair complete all as specified and directed .
Transportation of unserviceable transformer of up to 500 KVA capacity to workshop and return back for installation it on original position/location after repairing from workshop. Note : (Rate is deemed to be inclusive of transportation, T&P and man power) complete all as specified and directed .
M&L for factory opening of top cover by unscrewing nut, bolts & washers etc and taking out core assembly from tank by disconnecting from tap changer HT & LT side bushing stud to outside by dismantling the channel and disconnecting star delta connection for transformer up to 500 KVA capacity. After dismantling of Transformer and physical joint inspection of core coil assembly (removing all 3 limbs HV &LV winding from Core Assembly) washing of core assembly by hot oil for removing burnt carbon and copper particals and cleaning of complete top yoke by oil. reassemble of complete core assembly and core coil assembly providing new coils and new tap leads of tap changer including requisite insulation material. Re Tanking tightening of top cover fixing of HV & LV Bushing, tap changer connection, WTI & OTI Connection and CT connection. Filling of oil, conservator tank ready for final testing all as directed in presence of rep of MES. Note : Coil and insulation shall be measured and paid separately.
M&L in repairs for rewinding of HT coils with copper wire DPC/super enameled high quality matching with existing gauge and impedance including requisite insulating paper/material in each layer of winding after taking down old existing winding of HT coils of 11 KV transformer complete. Note : (i) The rate quoted against these items is inclusive necessary provision of all types of insulating materials , heating and varnishing etc.
All as per item No 4 here-in-before but LT coils with copper strips.
M&L for drying/ovening of complete Core coil assembly(CCA) in vacuum chamber and continuous monitoring to improve of IR Values after varnishing the coil to eliminate moisture content from Transformer up to 500 KVA capacity complete.
M&L for after drying and ovening and Re-assembling of up to 500 KVA Transformer core, testing of magnetic circuit for IR values, assembly and connection of OLTC of all phases, testing of transformer at low voltage, checking of ratio and polarity test. all as specified and directed. Note: (i) These operations/tests shall be carried out in the factory, results found satisfactory before bringing transformer to the original site for re-installation. (ii) The quoted rates shall be deemed to include complete testing before and after repairs, as per IS-2026, Megger Ratio, LV&HV High Voltage Test, DVDF and vector Group Test and leakage/Pressure Testing at 0.35 Kg for 24 Hrs to check the healthiness of the transformer, No load test, Full load Test, Impedance test, Voltage/Short Ckt impedance test.
S&F in replacement of transformer bushing on LT, 433 volt side including brass spindle/rods duly threaded at the end complete with gasket nut bolts and washer suitable for indoor/outdoor transformer capacity 63 KVA to 160 KVA complete all as specified and directed .
All as per item No 8 above but of capacity 200 KVA to 400 KVA
All as per item No 8 above but of capacity 500 KVA to 630 KVA
All as per item No 8 above but of capacity 1500 KVA
Supply and fixing in replacement of porcelain transformer bushing HT 11 KV including brass spindle/rods duly threaded at the end complete with gasket nut bolts and washer suitable for indoor/outdoor transformer capacity 63 KVA to 160 KVA complete all as directed by Engineer-in-Charge.
All as per item No 12 above but of capacity 200 KVA to 400 KVA
All as per item No 12 above but of capacity 500 KVA to 630 KVA
All as per item No 12 above but of capacity 1500 KVA
Supply and Fixing in replacement of transformer silica gel breather complete with all accessories for transformer of capacity 63 KVA to 160 KVA complete all as specified and directed.
All as per item No 16 above but of capacity 200 KVA to 400 KVA
All as per item No 16 above but of capacity 500 KVA to 630 KVA
All as per item No 16 above but of capacity 1500 KVA
S&F in replacement Thermometer of transformer capacity up to 1500 KVA complete all as specified and directed
M&L for ON load centrifuging and dehydration including filtration and cleaning of transformer oil by dehydration machine electric operated without any shutdown of transformer including testing oil sample before and after dehydration and filtration oil complete all as specified and directed . Note : (i) Transformer oil required for top up shall be measured and paid for separate (ii) Contractor have to arrange the dehydration machine and testing kit from his own resources without any extra cost. (iii) dielectric strength of transformer oil not less than 45 KV at 2.5 mm gap
Supply and filling the transformer oil in factory sealed barrel with IS-336 of di-electric strength not less than 45 KV at 2.5 mm gap and toping up the oil where ever required in Army Area Banar and all as specified and directed.
Supply and fill in replacement silica gel in transformer complete all as directed.
Painting of transformer after preparation of old painted surfaces of steel, by brushing/cleaning stain, greasy spots with thinner, applying two coats of spray painting with PU paint with spraying machine to transformer indoor/outdoor, fixed on poles or in Sub Station at different location after disconnecting of HT supply from incoming and LT supply from outgoing capacity 63 KVA to 160 KVA complete all as specified and directed .
Description all as per Serial item No 24 here-in-before but 200 KVA to 400 KVA capacity
Description all as per Serial item No 24 here-in-before but 500 to 630 KVA capacity
Disconnecting electric indoor/outdoor transformer 11 KV capacity up to 500 KVA from HT/LT terminals and lifting by hydra for installation on newly constructed plinth/2/4 pole structure complete all as specified and directed .
S&F in replacement the off load Tape changer suitable to 63 to 160 KVA indoor/outdoor transformer with fixing suitable make and fixing and making connection all as required and directed at site .
M&L for servicing the ON LOAD tap changer transformer capacity of 200 to 630 indoor/outdoor type by replacing the minor parts such as gear wheels, control wiring and checking the all connections and tap changing terminals decarbonizing and servicing the all moving parts of onload tap changer and all as specified and directed at site by Engr-in-Charge.
S&F in replacement of gasket for packing set of any size suitable for transformer of capacity up to 500 KVA made out of 6 mm thick cock sheet single piece including removing old unserviceable packing kit/ set cleaning the surface of the top cover etc complete all as specified and directed. Note :- The cost of opening of transformer cover/ top if required deemed to be included in the item rate of respective item .
Taking out faulty underground 11000 Volt HT cable of different sizes by excavation and removing Jodhpur Stone of any size and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new PCC cable covers as required. Note: (a) 11000 Volt HT cable & joints shall be measured and paid for separately under respective items of schedule. (b) Excavation, PCC Cover and earth work will be measured and paid for separately under respective items of schedule.
Taking out old unserviceable HT cable and supply, laying, jointing and testing XLPE insulated PVC outer sheathed and (earthed) PVC inner sheath, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 11000 Volts grade Earthed system and conforming to IS : 7098 (Part-II) of 1985 and size three core 95 sqmm 3 Core and laid in trenches/ducts/pipe or on road/pole all as required and directed at site. Note : i). Earth work and protection pipe etc shall be measured and paid separately. ii). Outdoor/indoor cable end termination/straight through joints shall be measured and paid separately.
Taking out old unserviceable HT cable supply and laying, jointing and testing XLPE insulated PVC outer sheathed and (earthed) PVC inner sheath, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 11000 Volts grade Earthed system and conforming to IS : 7098 (Part-II) and size three core 120 sqmm 3 Core and laid in trenches/ducts/pipe or on road/pole all as required and directed at site. Note : i). Earth work and protection pipe etc shall be measured and paid separately. ii). Outdoor/indoor cable end termination/straight through joints shall be measured and paid separately.
S&F cable route indicator made of RCC (Nominal Mix) type B-0 1:2:4 (12.5mm graded stone aggregate) with 8mm TMT Bar c/c of size 1m height X 60cm wide X 10cm thick tapered on top, visible above ground, duly painted with synthetic enamel paint of yellow colour base and letters with black paint. The description for writing for HT cable 11 KV as directed by Engr-in-charge complete all as specified and directed. Note : Rate for PCC 1:3:6 for foundation (min size 0.8mx0.3mx0.3m) of aggregate size 20mm for cable route indicator deemed to be included in the item.
S&F in repair cable jointing kit for 33 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 95 Sqmm to 120 Sqmm complete all as specified and directed by Engr-in-charge.
S&F in repair outdoor type heat shrinkable end termination cable joint kit including all material and accessories suitable for 3 core 50-95 sqmm cable of 11000 Volt grade all as per manufacture recommendation complete all as specified and directed.
S&F in repair indoor type heat shrinkable end termination cable joint kit including all material and accessories suitable for 3 core 50-95 sqmm cable of 11000 Volt grade all as per manufacture recommendation complete all as specified and directed.
S&F in repair outdoor type heat shrinkable end termination cable joint kit including all material and accessories suitable for 3 core 120 -185 sqmm cable of 11000 Volt grade all as per manufacture recommendation complete all as specified and directed.
S&F in repair indoor type heat shrinkable end termination cable joint kit including all material and accessories suitable for 3 core 120 -185 sqmm cable of 11000 Volt grade all as per manufacture recommendation complete all as specified and directed.
S&F in repair straight through heat shrinkable cable joint kit including all material and accessories suitable for 3 core 50 to 95 sqmm cable of 11000 Volt grade all as per manufacture recommendation complete all as specified and directed.
S&F in repair straight through heat shrinkable cable joint kit including all material and accessories suitable for 3 core120- 185 sqmm cable of 11000 Volt grade all as per manufacture recommendation complete all as specified and directed.
Taking down and servicing for HT switch gear VCB of capacity 400-630 Amp capacity ,11KV by tripping off the breaker and draw out the trolley and servicing and overhauling the mechanical parts with applying the grease and checking the control wiring and tripping mechanism, replacement of damaged minor parts such as control wiring, ferrules, HRC fuse, calibration of IDMT/Microprocessor numerical/digital relay existing on panels with secondary injection kit and setting the relay of earth fault, short circuit, time delay settings as per existing load of feeder and all as specified and directed by engr-in-charge at 33 KV MRS and depot area
Taking down and servicing for HT switch gear VCB of capacity 400-630 Amp capacity,33KV indoor type including control remote panel by tripping off the breaker servicing and overhauling the mechanical parts with applying the grease and checking the control wiring and tripping mechanism, replacement of damaged minor parts such as control wiring, ferrules, HRC fuse, calibration of processor numerical/digital relay existing on panels with secondary injection kit and setting the relay of earth fault, short circuit, time delay settings as per existing load of feeder and all as specified and directed by engr-in-charge at 33 KV MRS.
Taking down and servicing for HT switch gear RMU of 2/3/4 way ,11KV out door type tripping off the breaker servicing and overhauling the mechanical parts with applying the grease and checking the control wiring and tripping mechanism, replacement of damaged minor parts such as control wiring, ferrules, HRC fuses etc, calibration of processor numerical/digital relay existing on panels with secondary injection kit and setting the relay of earth fault, short circuit, time delay settings as per existing load of feeder and all as specified and directed by engr-in-charge.
M&L for replace the unserviceable spring charging motor in existing VCB's of existing specifications and all as specified and directed at site by Engr-in-Charge. Note :- Suitable for existing 12 KV Schneider indoor type HMX 630 Amp VCB.
M&L for in replacement of taking down and replace the vacuum interrupter of existing VCB's of any make and connecting arrangement and all as required and directed at site by Engr-in-Charge. Note :- Suitable for existing 12 KV Schneider indoor type HMX 630 Amp VCB.
S&F in replacement of tripping coil suitable for VCB 400 to 630 Amps to trip the VCB with the operating voltage of 24 vols DC supply and all as specified and directed. Note :- Suitable for existing 12 KV Schneider indoor type HMX 630 Amp VCB.
Supply and fixing, testing , commissioning in replacement of microprocessor relay of 24 volts DC supply operated with earth fault ,over current and with TDS to protect the HT VCB/OCB of 400 to 630 Amps along with control wiring of CT primary/secondary winding and all as specified and directed. Note :- Suitable for existing 12 KV Schneider indoor type HMX 630 Amp VCB.
Supply and fixing in replacement of spring of VCB charging/tensioning with top and bottom connecting assembly suitable to fix on existing VCb of any make and model along with connected accessories and all as specified and directed. Note :- Suitable for existing 12 KV Schneider indoor type HMX 630 Amp VCB.
Supply and Fixing Replacement of Operating mechanism of 11 KV RMU spring charge.
Supply and Fixing Replacement of Operating mechanism of 11 KV RMU Earthing switch. Note :- Item No. 50 to 51 suitable for existing 12 KV Schneider, Type FBX-E/12-21/CCC 630 Amp VCB
Supply, installation, commissioning and testing in replacement of 11 KV current transformer (CTs), indoor type, resin cast epoxy type of 18.1 KA/Sec having ratio 100/50/5, 15 Amps having Core 1 : Class 5P10, 10VA for protection, Core 2 : Class 0.5, 10VA for metering including associated wiring complete all as specified and directed.
M&L and fixing in true Vertical position prestressed concrete pole 11.00 Mtr long of size 152mm x 152mm at top and 152 mm x 260mm at bottom of class-9 confirming to relevent IS-1678-1998 code and dismantling and removing the old unsv PCC pole and all as specified and directed at site NOTE - Excavation and Earth work and PCC in foundation shall be measured and paid separately.
S&F in replacement of GI stay assembly set comprising of 14mm dia 400mm iron stay bow and16mm dia, 2150mm long stay rod stay plate 230x230x6mm thick, GI stay wire 7/3.15 mm SWG of required length complete with all accessories as shown in electric plate No 1 of SSR Part 1 2009 complete with excavation earth work including PCC 1:3:6 of required quantity with loop insulator, clamps nut bolts etc complete all as specified and directed.
Material and labour plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in base of the pole or in any situation all as specified and directed.
Material and labour plain cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of the pole or in any situation all as specified and directed.
Dismantling of existing defective HT 33 KV Gang operated air break switch and Supply and installation, commissioning and testing of HT 33 KV outdoor type triple pole gang operated air-break switch double stack type suitable for horizontal mounting rotating type with 9 insulator 200 amps current rating complete mechanically operated mechanism from ground level consisting of operating rod of 25 mm bore medium grade GI pipe of suitable length with locking arrangement, flat iron clamp 50x6mm including MS channel of suitable size and length for fixing GOD including bolts, nuts and washers complete all as directed
Dismantling of existing defective HT 11 KV Gang operated air break switch and supply installation, commissioning and testing 11 KV outdoor type, gang operated Air break switch 200 Amp rated triple pole mechanically operated, mounted on insulator and steel frame with operating mechanism worked from ground level with 25mm GI pipe (Med grade) operating rod of suitable length with expulsion fuses of rating upto 200 Amp comprising of 12 insulators all as specified and directed.
Supplying and fixing in replacement male contact/moving contact for Horizontal/Vertical gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.
Supplying and fixing in replacement female contact /fix contact jaw for Horizontal/Vertical gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.
Supplying and fixing in replacement tinned copper flexible jumper 200 Amp/400 Amp for gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.
Supplying and fixing in replacement MS jumper carrier for gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.
Supplying and fixing in replacement back connector plate for gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.
Supplying and fixing in replacement porcelain post insulator for gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.
Supplying and fixing in replacement drop out fuse element 5 to 30 Amp complete all as directed at site by Engr-in-charge.
Supplying and fixing in replacement drop out fuse element 60 Amp complete all as directed at site by Engr-in-charge.
M&L in replacement of earthing with Galvanised Steel earth plate of size 60x60cmx6mm thick electrode and 32x6mm GI strip as earth lead, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to 32x6mm earth strip by means of nuts, bolts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I, connected to earth test terminal point all as specified or as indicated including testing on completion (Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, CI cover, funnel with watering pipe, suitable size of light grade GI Protection pipe for earth strip in ground etc. all as required at site for complete earthing). Note: Testing of earthing shall be carried out after completion of earthing. Payment for earthing shall be admissible after satisfactory test result.
M&L in replacement of GI strip of size 32x6 mm including mounting on PVC/Porcelain insulators on wall and buried in ground depth not less than 60 cm in ground complete all as specified and directed by Engineer-in-Charge.
All T&P expenditure for tracing out the HT UG cable fault by pin point with cable fault locating machine mounted vehicle including all T&P expenditure to rectify the fault within 08 hrs to restore the supply of HT 11 KV feeder at Banar Mil station and all as specified. Note : The fault will be measured one unit by charging of one HT cable , multiple faults at same cable will be measured single fault and HT Cable joints will be measured and paid separately and earth work will be paid under relevent item of Schedule and delay beyond 08 hrs will be recovered Rs-1000/- per hour from work done amount.
S&F in replacement 25 mm bore medium grade GI pipe including all fitting for HT 11 KV Gang operated air break switch all as specified and directed.
S&F in replacement tubes 'light grade' galvanized with all fitting laid in trenches/on wall/pole/under road crossing/under existing bridge with suitable clamps made bt FI 25x3mm if required to fix on wall/pole of size 80 mm dia including all fitting all as specified and directed.
Supply and fixing cross arms, bracings, supports, clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, welding, bending colt or hot, drilling holes for bolt. In any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminum paint and all as specified and directed.
M&L for cutting the road/PCC for laying the cable up to depth 1.5 mtr and making finishing with PCC of disturbed surface of road/PCC and all as specified and directed directed. Note : PCC will be measured under relevant item of Sch.
M&L for resagging of overhead conductor section of 11 KV including binding/re-binding of conductor with suitable size of wire and providing of jumpers at the ends as per site requirements complete all as specified and directed by Engr-in-Charge.
M&L for replacement of rusted/broken GI earth wire of 4 mm dia for guard on Overhead line by providing reels and clamps and any other items required for fixing as per site requirement complete all as specified and directed by Engr-in-Charge.
Dismantling and taking down HT pole of old ACSR conductor complete all as specified and directed by Engr-in-Charge.
M&L for Replacement of old ACSR conductor with new ACSR conductor including binding of wire and providing jumpers at the end as per site requirement complete all as specified and directed by Engr-in-Charge.
Fixing and restretching of old serviceable (ACSR) conductor obtained from items No 77 here in before including binding complete all as specified and directed.
M&L for checking , tightening & Replacement of jumpers , clamps connectors of 33 KV bus bar for the Power transformer in the yard / sub station complete all as specified and directed by Engr-in-Charge.
M&L in replacement of Supply, design, Installation, testing and commissioning of totally enclosed busbar chamber of outdoor type IP-55 protection fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door type including locking arrangement, aluminum bus bar 400 Amp rating with air tight insulated mounted on insulators, incoming and outgoing cable chamer suitable for size upto 185 Sqmm HT cable complete suitable for operation of 11000 volts grade , 50 hz, AC supply having Angle iron frame with legs of 50Cm height made out of 65x65x6mm angle iron grouted on PCC (1:3:6) and platform should be 50cm above the normal ground level and all as specified and directed.
S&F Pin type, porcelain, vitreous, white brow or green insulator including one galvanised mild steel spindle, two galvanized iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade with fixing on existing 2 pole/4pole/single pole including taking down of old unsv insulator and all as specified and directed.
Supply and fix danger notice plate 1.6 mm thick mild steel sheet vitreous enameled white with latters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of appropriate size for 11 KV system size 25 x 20 cm all as specified and confirming to IS : 2551-1982.
Supplying & Fixing in replacement Caution plate “CAUTION MEN AT WORK" of size 40cmx15cm made out of white acrylic sheet with Red coloured glow tape.
Supply fixing and connecting and testing single pole zinc oxide (gapless surge type) heavy duty station class, self supporting outdoor type lighting arrester having rated voltage 09 KV (rms) discharge current 65 KA insulation level 28/75 KV/KVP (Peak) suitable for rated system voltage of 11 KV supply system with maximum continuous operating voltage (MCOV) not less than 7.65 KV (rms) with highly non linear ceramic resister made of zinc oxide in hermetically sealed container complete with metal base, base insulator and suitable terminals for ground connections and pressure relieving arrangement complete all as specified Note : The rate quoted against above item shall include necessary fixing arrangement of lightening arrester on two pole/four pole structure as per recommendations of manufactures.
Supply fixing and connecting and testing single pole zinc oxide (gapless surge type) heavy duty station class, self supporting outdoor type lighting arrester having rated voltage 30 KV (rms) discharge current 65 KA insulation level 35/75 KV/KVP (Peak) suitable for rated system voltage of 33 KV supply system with maximum continuous operating voltage (MCOV) not less than 17.05 KV (rms) with highly non linear ceramic resister made of zinc oxide in hermetically sealed container complete with metal base, base insulator and suitable terminals for ground connections and pressure relieving arrangement complete all as specified Note : The rate quoted against above item shall include necessary fixing arrangement of lightening arrester on two pole/four pole structure as per recommendations of manufactures.
Taking out old unserviceable 33 KV pin insulator including taking out 33 KV OH ACSR conductor and supply and fix 33 KV pin type, porcelain, vitreous, insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut for fixing of insulator on HT pole including refixing the OH ACSR conductor at the same place including binding the conductor to insulator with new binding wire complete all as directed.
M&L for replacement of defective/damaged Disc insulators suitable for 33 KV overhead conductors including removing/providing jumpers with line conductors as per required at site complete all as specified and directed by EIC.
Excavation in trenches in any type of soil not exc 1.5 mtr in depth and 1.5 mtr wide and getting out for laying of cables.
All as per ser No-88 above but depth exc 1.5 mtr but not exc 3.00 mtr
M&L for tibba sand filling in trenches dry and clean sand unwashed including punning around cable for protection of under ground cable complete all as specified and directed.
Supply and laying reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mmx180mmx40mm laid perpendicular to cable length in trench air gap should not more than 5mm to each other after sand cushioning to cable and all as specified and directed.
Returning and filling in including spreading, leveling , watering and well ramming in layers not exceeding 25 cm thick of excavated earth complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 mtr and depositing at a level not exceeding 1.5 mtrs above the starting point complete all as specified and directed.
M&L for Surface excavation n.exc 30 cm deep and averaging 15 cm and getting out in any type of soil including cutting and removing grass, vegetation, bushes/shrubs etc from surrounding of 02 Pole/ 4 Pole structure and LT/ HT Panel E/M installations and removing all rubbish and dressing the gravel/soil and spaying the one time herbicide approved brand (Roundup/No weed) to prevent the further vegetation and all as specified and directed.
Supply and laying the graded coarse aggregate 40mm size for E/M installations of 33KV MRS yard/2/4 pole HT/LT pole structures/surrounding area of RMU including cleaning the vegetation developed and making plane of surface and all as specified and directed at site.
Material and labour for cutting the branches/trees near the HT OH line upto clearance area 5mtr around OH line by cutting the branches and removing the wastage from site to disposal area and all as specified and directed, Note :-(i) The necessary man power tool and plant , cutting tools and JCB if required for cutting/ prunning of branches is deemed to including in the rate quoted for the job (ii) Proper shut down will be taken from JE E/M only.
Supply, fixing and testing in replacement of 12V 150 AH Tubular type maintenance free battery complete connected to existing HT VCB Panel of 33/11 KV complete all as specified and directed by Engr-in-Charge.
Preventive maintenance/servicing and testing of power transformer 3.15 MVA of 33/11KV at MRS ABOD Banar, following test shall be carried out at site by calibrated instrument (calibration certificate shall be submitted) complete all as specified and directed by Engineer-in-Charge. (a). Magnetic balance test (b). IR Test (c). Open circuit test (d). Short circuit test (e). Transformer oil test (Test shall be carried out at govt approved lab) (i). Water content test (ii). Neutralisation value (total acidity) test.
Preventive maintenance/servicing of power transformer 2.0 MVA of 33/11KV at MRS ABOD Banar, following test shall be carried out at site by calibrated instrument (calibration certificate shall be submitted) complete all as specified and directed by Engineer-in-Charge. (a). Magnetic balance test (b). IR Test (c). Open circuit test (d). Short circuit test (e). Transformer oil test (Test shall be carried out at govt approved lab) (i). Water content test (ii). Neutralisation value (total acidity) test.
Preventive maintenance /servicing and testing of indoor/outdoor type distribution transformer of capacity 200 KVA to 400 KVA at Banar Area, following test shall be carried out at site by calibrated instrument (calibration certificate shall be submitted) complete all as specified and directed by Engineer-in-Charge. (a). Magnetic balance test (b). IR Test (c).WTO/OTI tripping (d).Oil level and leakage (e). Transformer oil test (i). earthing valve check body and neutral (ii).Megar/dielectric strength Complete all as specified and directed by EIC.
Preventive maintenance /servicing and testing of indoor/outdoor distribution transformer of capacity 500 KVA to 630 KVA at Banar Area, following test shall be carried out at site by calibrated instrument (calibration certificate shall be submitted) complete all as specified and directed by Engineer-in-Charge. (a). Magnetic balance test (b). IR Test (c).WTO/OTI tripping (d).Oil level and leakage (e). Transformer oil test (i). earthing valve check body and neutral (ii).Megar/dielectric strength Complete all as specified and directed by EIC.
Preventive maintenance /servicing and testing of indoor type distribution transformer of capacity 1500 KVA at Banar Area, following test shall be carried out at site by calibrated instrument (calibration certificate shall be submitted) complete all as specified and directed by Engineer-in-Charge. (a). Magnetic balance test (b). IR Test (c).WTO/OTI tripping (d).Oil level and leakage (e). Transformer oil test (i). earthing valve check body and neutral (ii).Megar/dielectric strength Complete all as specified and directed by EIC.
Supply and fixing in replacement of 11000 volts grade HRC fuse barrel type of rating upto 20 Amps suitable for exiting VCBs and all as specified and directed by EIC.
Sachiyay maa Electricals
Shri Electrical Enterprises
INDO CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .