Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAdmitted-Finance EDOLIKUNNATH H CHENNAMANGALUR PO MUKKAM VIA CALICUT 673602 | KOZHIKODE | KERALA | 673602 | ₹7.6 L | L1 | Admitted-Finance |
| 2 | L2₹8.8 LAdmitted-Finance | ₹8.8 L | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | E K IBRAHIMKUTTY L1 | PRAJEESH V K L2 |
|---|---|---|---|---|---|
| 1.00MASONRY WORK | |||||
| 1.01Laterite masonry with neatly dressed laterite stone of size 35x20x20cm or nearest size for superstructure above plinth level up to floor two level including all cost of materials, labour charges etc. | |||||
| 1.01 | Cement Mortar 1:6 (1 cement : 6 coarse sand). | 8.41 | cum | 10,000 ₹84,100 | 9,500 ₹79,895 |
| 1.02 | Providing and fixing terracotta jali of 200mmx200mmx75mm or nearest size, of any specified design, laid with cement-based high polymer modified, improved performance, slip resistant, extended open time, deformable tile adhesive (water based) conforming to IS:15477:2019(Type 3 'T' S1), in average 6 mm thickness including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the jali shade, jali slab without any chamfers etc. in superstructure above plinth level upto floor five level. | 4.2 | sqm | 3,100 ₹13,020 | 3,000 ₹12,600 |
| 2.00CLADDING WORK | |||||
| 2.01Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. | |||||
| 2.01 | Granite work | 24 | metre | 600 ₹14,400 | 5,000 ₹1.2 L |
| 2.02 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4 mm thick aluminium composite panel material consisting of 3 mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5 mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. | 2.88 | sqm | 4,900 ₹14,112 | 3,000 ₹8,640 |
| 2.03Stone work (machine cut edges) for wall lining (veneer/cladding work) upto 2 m height, laid with cement-based high polymer modified, improved performance, slip resistant, extended open time, deformable tile adhesive (water based) conforming to IS:15477:2019(Type 3 'T' S1), in average 6 mm thickness and pointing/grouting in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade: | |||||
| 2.03 | Laterite stone cladding tile (20mm thick or nearest) | 53.16 | sqm | 2,600 ₹1.4 L | 2,400 ₹1.3 L |
Updated dates
Tender Value
₹7.8 L
EMD Value
₹15,700
Closing Date
25 Feb 2026, 6:00 pmClosed
Director
NIT Calicut, NIT Calicut Campus PO, Kerala, 673601
MED Entrance renovation in DB
2026_NITC_895814_1
Engg/D1/JE 5 (i/c)/472
Open Tender
Civil Works
45 days
NIT Calicut, NIT Calicut Campus PO, 673601
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹15,700
Yes
24 Mar 2026
28 Jan 2026
27 Feb 2026
28 Jan 2026
25 Feb 2026
28 Jan 2026
MASONRY WORK
Laterite masonry with neatly dressed laterite stone of size 35x20x20cm or nearest size for superstructure above plinth level up to floor two level including all cost of materials, labour charges etc.
Cement Mortar 1:6 (1 cement : 6 coarse sand).
Providing and fixing terracotta jali of 200mmx200mmx75mm or nearest size, of any specified design, laid with cement-based high polymer modified, improved performance, slip resistant, extended open time, deformable tile adhesive (water based) conforming to IS:15477:2019(Type 3 'T' S1), in average 6 mm thickness including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the jali shade, jali slab without any chamfers etc. in superstructure above plinth level upto floor five level.
CLADDING WORK
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
Granite work
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4 mm thick aluminium composite panel material consisting of 3 mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5 mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
Stone work (machine cut edges) for wall lining (veneer/cladding work) upto 2 m height, laid with cement-based high polymer modified, improved performance, slip resistant, extended open time, deformable tile adhesive (water based) conforming to IS:15477:2019(Type 3 'T' S1), in average 6 mm thickness and pointing/grouting in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade:
Laterite stone cladding tile (20mm thick or nearest)
WOOD AND P. V. C. WORK
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
Second class teak wood
STEEL WORK
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
GI Tubular TATA or equvalent
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, bufing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
FLOORING
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent
Supplying and paving best quality highly compressed exterior grade floor paving tiles in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).
ROOFING
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing multi walled transparent /opaque 10 mm thick polycarbonate sheet of required colour blue, brown or green etc. UV co-extruded and having UV coating on one side multi walled sheet of weight not less than 1.60 to 2.05kg/sqm as approved by Engineer-in-charge. The light transmission from transparent or translucent or opaque polycarbonate sheet varies from 30 to 80% and shall be decided by engineer in charge as per requirement. The panel shall satisfy the Dart drop impact test for value above 15 and upto 60 Joules and confirm either fame retardancy of class UL-94HB/94V-0 category as per ISI4434:2023 or category VO & HB as per ASTM D635-I8 or BSI DO classification as per EN13501 for fire safety. The yellowness index tested as per ASTM E313 (DI925) shall be less than or equal to 2 or it shall be I units as per ASTM D 2244 at the time of installation and shall be less than or equal to 10 as per ASTM E313 (1) 1925) or 6 units as per ASTM D 2244 on a sample after 5000 Hours of exposure of UV / sun light. The multi walled poly carbonate sheet shall he fixed on tubular steel structure with aluminium Alcox section of size 60x18x2 mm (anodized 25 micron thick) and weight not less than 0.462 kg/metre. Weather proof Neoprene/ EPDM rubber gasket shall be fixed on both side of joints to make the whole structure water tight as per approved design/drawings. The aluminium section shall be fxed on Joints at both sides (top & bottom) of polycarbonate sheet to hold the sheets rigidly together. The weather proof neoprene gasket and aluminium profile shall be fixed and sealed with silicon sealant to make the Joints fully water proof. The open overhead ends of polycarbonate sheet to be sealed with anodised aluminium U Profile/ channel of size 10x10x 1.5 mm thick of weight not less than 0.2kg/m. The polycarbonate sheet and aluminium profile shall be fixed to MS Framed Structure with self-taping and self-drilling 55mm long steel screws to be fixed @ 300mm centre to centre. The rate shall be inclusive of cost of all material involved such as polycarbonate sheet, aluminium profile and aluminium channel, EPDM gasket, Self-taping screws, nut bolts, Silicon sealant or any other material required for fixing the sheet but excluding the cost of steel structure which shall be paid separately including hoisting the sheets and fixing in position in required scaffolding shape. The rate shall also include the cost of all T & P scafolding and safety precautions required during execution of the work. The entire work shall be executed
10 mm thick and U- value not more than 2.50 W/m2K
Providing and fixing false ceiling with PVC panel board in aluminium frame work with necessary edge/intermediate trims, clips, screws, etc. complete (aluminium framework shall be paid separately)
PVC panel board of 7.5 mm or nearest thickness of approved wooden grain design & quality
FINISHING
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.
On steel work
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
Two coats
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.
With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Melamine polishing on wood work (one or more coat).
Finishing Floors with premium floor guard (Apex floor guard or equivalent) with Silicone additives of required shade:
One or more coats applied as per manufacturer specifications
REPAIRS TO BUILDING
Repair to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge.
Dismantling and Demolishing
Demolishing cement concrete manually/ by mechanical means including disposal of material outside campus as per direction of Engineer - in - charge.
Nominal concrete 1:3:6 or richer mix (including equivalent design mix)
ALUMINIUM WORK
Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately).
Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200 mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3 mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer- in-charge.
CONSERVATION OF HERITAGE BUILDINGS
Applying breathable, non-reactive, antifungal, and water repellant Silane/ Siloxane chemical as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the existing sand stone masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer-In-charge (The rate is inclusive of all materials & labours involved except scaffolding).
Supply installation testing and commissioning of backlit name board for department as per design finalised by engineer in charge
Supply installation and testing of building name/department name lettering of given size as per instruction of engineer in charge
Please Enable Macros to View BoQ information