Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance NO 23 SECOND MAIN ROAD RAJAMMAL NAGAR MADAMBAKKAM CHENNAI 600 126 | CHENNAI | CHENGALPATTU | TAMIL NADU | 600126 | Admitted-Finance |
| 5 | Admitted-Finance 21 KAWARDHA COLLECTORATE ROAD KAWARDHA KABIRDHAM CHHATTISGARH 491995 | KABIRDHAM | CHHATTISGARH | 491995 | Admitted-Finance |
Tender Value
₹12.1 L
EMD Value
₹24,160
Closing Date
21 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Army Trivandrum
Office of Garrison Engineer Army, Thirumala Post, Trivandrum-06
As per tender documents
2020_MES_396051_2
GE (ARMY) TVM 9358/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Trivandrum
AS per NIT
8 documents required · 8 mandatory
₹500
GE Army Trivandrum
₹24,160
Yes
27 Jan 2021
28 Dec 2020
23 Jan 2021
29 Dec 2020
21 Jan 2021
7 Jan 2021
29 Dec 2020 - 6 Jan 2021
60 days
Amount
Supply and fix in replacement for the following items mentioned in below for the upgradation of lift insalled at MH Trivandrum.Make of Lift: ECE.Note:(i)Testing ,commissioning including load test of the lift shall be carried out after repair/replacement of below mentioned items for satisfactorly as directed and specified .(ii) The work shall be exicuted through the agency of MoU signed with the OEM ( ECE).
Supply Fix new Master control unit PCB with TIC V controller
Material and labour for replacement of shaft wiring for ARD,contollers etc
Supply fix Limit switches.
Supply and fix LCU PCB with button
Supply and fix CCU PCB with button
Supply and fix cabin false ceiling with light and fan
Supply and fixing steel Main rope as per IS specified
Supply and Fix Travelling cable
Supply and fix Auto Rescue Divice.
Material and labour for Landing Door with Assembly.
Material and labour for Car door with assembly.
Taking down carefully copper/Alluminium point wiring(light,fan,socket or power) complete,and making good disturbed sufaces of walls,floors etc.
.Point wiring with 1100 volts grade 1.5 sqmm PVC insulated unsheathed, multi stranded, copper conductor cable drawn into and including rigid PVC conduit and accessories concealed in wall/roof/floors with continuous 1.5 sqmm PVC insulated unsheathed multistranded copper conductor cable as earth continuity conductor and connecting to common earth dolly including 1.6mm thick MS terminal boxes concealed in wall covered with 3mm thick plastic laminated sheet cover fixed with cadmium plated iron screws for mouunting of switch/sockets for:-
One light/fan/exhaust fan point controlled by one switch
One light point controlled by 2 two way switches
Point wiring for one 3 Pin socket outlet 5 Amps on indepedent board with 1100 volts grade 2.5 sqmm PVC insulated unsheathed, multi stranded, copper conductor cable drawn into and including rigid PVC conduit and accessories concealed in wall/roof/floors with continuous 2.5 sqmm PVC insulated unsheathed multistranded copper conductor cable as earth continuity conductor and connecting to common earth dolly including 1.6mm thick MS terminal boxes concealed in wall covered with 3mm thick plastic laminated sheet cover fixed with iron screws for mounting of switch/socket etc on independent board
Point wiring for one 3 Pin socket outlet 15 Amps on indepedent board with 1100 volts grade 4.0 sqmm PVC insulated unsheathed, multi stranded, copper conductor cable drawn into and including rigid PVC conduit and accessories concealed in wall/roof/floors with continuous 4.0 sqmm PVC insulated unsheathed multistranded copper conductor cable as earth continuity conductor and connecting to common earth dolly including 1.6mm thick MS terminal boxes concealed in wall covered with 3mm thick plastic laminated sheet cover fixed with iron screws for mounting of switch/socket etc
Switch socket combination flush type, 3 pin 15 Amps and 3 pin 5 Amps multi purpose, 240 volts all as specified
Supply and fix in repair Switch socket outlet piano flush type, 5 Amps, 5 pin, multipurpose, 240 volts all as specified
Supply and fix in repair switch piano flush type, one way, single pole, 5 Amps, 240 volts, and marked light or fan all as specified
Supply and fix in repair switch piano flush type, two way, single pole, 5 Amps, 240 volts all as specified
Supply and fix in repair ceiling rose three phase/PVC ploycorbonate isolated body all as specified
Supply and fix in repair electronic step type fan regulator, 300 wats, single phase, 230 volts 50 Hz to be housed in terminal box including connecting up all as specified
Supply and fix in repair MCB DB TPN 4 way vertical double door 415 volts, with minimum capacity of 200 Amps rated copper busbar including necessary dummy plate all as specified
Supply and fix in repair MCB DB SPN-8 way 230 volts double door type with minimum capacity of 200 Amps rated busbar including necessary dummy plate complete all as specified
Supply and fix in repair MCB single pole (SP), 240 volts, of capacity 06 to 32 Amps
Supply and fix in repair MCB single pole and neutral (MCB SPN), 230 volts, of capacity 32 Amp
Supply and fix in repair MCB triple pole and neutral (MCB TPN), 415 volts, of capacity 63 Amps Ccurve
Supply and fix in repair MCB triple pole (MCB TP) 415 volts of capacity of 63 Amps Ccurve
Supply and fix in repair RCCB 63 Amps 4 pole 440 volts 50 Hz 100 mA for earth leakage, over load and short circuit protection.
Supply and fix in repair LED tube light fitting 20W suitable for and including 1x20 watt LED tube rod.
Material and labour for replacement for earthing galvanised steel earth plate electrode 600X600X6.30mm thick burried directly in ground (earth plate not less than 2.25 mtr deep below normal ground level with top edge of the plate less than 1.5 mtr below normal ground level) connected to GI strip 32x6mm by means of bolts, nuts, check nuts, and washers, of galvanised iron or steel including GI pipe light grade 40 mm bore for protection of earth lead,GI funnel and wire mesh etc complete all as shown in Electrical plate no 3 of SSR 2009(part- I)including necessary excavation earth work, form work.earth pit of size 450X450X300 mm of PCC M-15 (Nominal mix)using stone aggregate earth pit cover of PCC and 20 mm bore light grade GI pipe for watering and charcoal dust,common salt, and connected to test point 7.5 mtr from earth pit including testing complete all as specified and as directed.
Supply and fix in repair aluminium strip 25 x 3 mm incl clamps, screws,supporting insulators etc
Supply and fix in repair Sub main wiring FR PVC insulated copper coductor 4x10 sq mm+2x6 sqmm earth wire in PVC coduit fixed to wall or floor etc.
PHEJAYS AGENCIES
Powertech Equipments And Services
sanjay Traders
AB CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .