Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.3 LAccepted-AOC SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER | |
| 2 | L2₹43.0 L+₹1.2 L (2.97%)Rejected-AOC SHOP NO 1 KARGI CHOWK HARIDWAR BY PASS DEHRADUN UTTARAKHAND | L2 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 3 | L3₹46.5 L+₹4.8 L (11.5%)Rejected-AOC H NO 02 BALLUPUR ROAD DEHRADUN UK PIN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 4 | L4₹48.5 L+₹6.8 L (16.3%)Rejected-AOC | L4 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 5 | L5₹51.2 L+₹9.5 L (22.7%)Rejected-AOC | L5 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
Tender Value
₹59.6 L
EMD Value
₹1.1 L
Closing Date
18 Jan 2024, 6:00 pmClosed
GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
REFURBISHMENT OF ROOM NOS 200, 201, 203A, 203B, 203C OF MAIN BUILDING TOP FLOOR AT DEAL DEHRADUN OF AEW AND CS DATA LINK LAB AND SITTING PLACE AT DEAL UNDER GE (I) RND DEHRADUN
2023_MES_634040_1
GE(I)RND/9309/E8/23-24
Open Tender
Civil Works
Item Rate
180 days
Dehradun
Class C Category a (i) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 and 1.5 of section of Part I of MES Manual on contracts-2020 as available in all MES formations (ii) Copy of police verification /passport.
6 documents required · 6 mandatory
₹1,000
Yes
GE I RND DEHRADUN
₹1.1 L
Yes
29 Jan 2024
22 Dec 2023
20 Jan 2024
22 Dec 2023
18 Jan 2024
4 Jan 2024
22 Dec 2023 - 4 Jan 2024
Amount
Demolition of brick or stone boulders masonary built in cement mortar or cement lime mortar including all quions, arches pillars etc but excluing ashlar facings ressed stone works and precast concrete artiles and removal of demolished materials to a distance exceeding 500 M but not exceeding 1000mtr, complete all as specified and directed.
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing debrish and rubbish off the premises and stacking serviceable tiles complete all as specified and directed.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete all as specified and directed.
Providing and fixing Ist quality ceramic glazed wall tiles of size size 300 x 450 / 350x450 / 350x250 conforming to IS: 15622 of approved make, in all colours, shades except burgundy, bottle green, black in skirting, risers of steps and dados,over and including 10 mm thick rendering in cement mortar (1:3), rough finish to receive the tiles and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete all as specified and directed.
M & L for Virified Ceramic tiles 10 mm thick dark shade double charged/ ultracharged (square/ rectangular) polished area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat in cement slurry @3.3kg /sqm and pointed inwhite or colour cement to match with shade over and including 20 mm thick screed bed in CM 1:4 with complete all as specified and directed.
M&L for Virified Ceramic tiles 10 mm thick dark shade double charged/ ultracharged (square/ rectangular) polished as on vertical surfaces such as skirting / dado over and including 10mm thick rendering in cement mortar 1:3 rough finish to receive the tiles set and jointed in neat in cement slurry @3.3kg /sqm and pointed inwhite or colour cement to match with shade with complete all as specified and directed.
Taking down existing cement or cement lime plaster/Grit wash of any description and in any position on brick or concrete surfaces etc including racking out joints, hacking for key scrubbing down with water etc complete all as specifed and directed.
M & L for 15 mm thick rendering on fair faces of brick work or concrete surfaces with cement mortar 1:6 finished even and smooth (without using extra cement) complete all as specified and directed.
M&L for Rendering 15 mm thick on fair faces of concrete/brick surfaces in cement mortar 1:4 mixed with water proofing compound as per manufacturer's instruction, finished fair and even without using extra cement r etc complete all as specified and directed. Note :- WPC shall be measured and paid for seprately as supply only item under respective item of sch 'A'/BOQ. Note:- work to carried out upto hight of 4th story bldg.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces over and including 3 mm thick water proof wall care puty in two coat or layers including preparation of newplastered external surfaces of wall complete all as specified and directed.
M & L for preparing new plastered surface of walls and applying two coat of Oil Bound Distemper over and including a coat of alkali resistant primer over 3mm thick damproof wall care putty in two layer complete all as specified and directed.
M&L for complete removel of existing treated plastered or unplastered surfaces on walls and prepared surface and make the surface smooth by rubbing with sand papers etc and applying Two coat of cement based paint complete all as specified and directed.
M&L for preparation of old decorated plastered or unplastered surfaces of wall/ ceiling, cornices etc by brooming down or steel wire brushing down scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, and applying one coats of oil bound distemper complete all as specified and directed.
Demolition of ( reinforced cement concrete) (reinforcement cut as required to facilitiate demolition) of any description and in any positionnot otherwise specifically provided for and removal of demolished materials to a distance exceeding 500 M but not exceeding 1000mtr, complete all as specified and directed.
M&L Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) complete all as specified and directed.
M & L for use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports overhangs etc, also splays between floors and beams, etc., work in rough finished flat surfaces of concrete complete all as specified and directed.
M & L for mild steel TMT bars of 08mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and directed.
All as per items No 18 above but 5mm dia and over upto and incl 10mm dia in stirrups, spacers and binders.complete all as specified and directed.
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead of area not exc. 3 Sqm each complete all as specified and directed.
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead of area exc. 3 Sqm complete all as specified and directed.
M&L for 0.9 mm thick Decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions complete all as specified and directed.
M&L for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed.
S&F 18mm to 20mm thick solid factory made PVC board for cup board /cabinate shutter with one side 1mm thick printed pvc sheet other side plain pvc sheet suitable fixed with &including suitable pvc frame, matching colured beading to cover all edges & screwed portion of frame, Magnetic catcher as per specification & drawing complete all as specified & directed.
Providing and fixing double strip (horizontal type) magnetic catcher of approved quality in cupboard/word robe shutters, including fixing with necessary screw etc complete all as specified and directed. Double strip (horizontal type)
Providing and fixing M.S. Piano hinges ISI marked IS: 3818 (overall width 35 mm) finished with nickel chromium plating grade I as per IS: 1068 and fixing with necessary screws etc complete all as specified and directed.
Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws complete all as specified and directed.
M&L for preparation of new or previously untreated wooden surfaces exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparing of old painted wooden surfaces or wood based materials over 10cm width or girth with sand papers etc and applying one coat of synthetic enamel paint on old prepared surfaces of wooden complete all as specified and directed.
Providing and fixing ISI marked 100x58x1.90 mm M.S. pressed butt hinges bright finished with necessary screws etc. complete all as specified and directed.
PSupply and fixing 75 mm aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete all as specified and directed.
Supply and fixing 250x10 mm ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete all as specified and directed.
S&F 300mm long, 16mm dia Aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminium alloy complete all as specified and directed.
M&L preparation of new or previously untreated steel surfaces of any description over 10 cm width or girth & applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Supply and fixing in repair G.I. Pipes 15 mm dia nominal bore complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall complete all as specified and directed.
Supply and fixing in repair G.I. Pipes 20 mm dia nominal bore complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall complete all as specified and directed.
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 complete all as specified and directed.
S&F in repair 15mm bore stop valve, cast copper alloy screwed down high pressure with crutch or butterfly handle chromium plated fancy type long shank and cup(concealed type), screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F PVC conneciton 450 mm long, 15mm size with PTMT nuts complete all as specified and directed.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap complete all as specified and directed.
S&F 100 mm dia CP brass granting round with hole complete all as specified and directed.
S&F 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS:8931 complete all as specified and directed.
S&F bright finished brass hanging type floor door stopper with necessary screws, etc. complete all as specified and directed.
M&L for powder coated aluminium (minium thickness of powder coating 50 micron) aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, complete all as specified and directed. directions of GE. (Glazing, paneling and dash fasteners to be paid for separately).
M&L for providing powder coated aluminium (minium thickness of powder coating 50 micron) shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) complete all as specified and directed.
M&L for providing aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the GE. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment. complete all as specified and directed.
M&L for providing assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. complete all as specified and directed.
M&L for providing and fixing factory made Two Track two panels sliding window made of frame 67x50 mm & sash 46x62 mm both having wall thickness of 2.3+ 0.2 mm and sigle glazing bead / double glazing bead of appropriate dimension. (Area of window up to 2.50 Sqm) uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, complete all as specified and directed. & direction of GE. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
M&L for providing and fixing 12 mm thick prelaminated particle board with decorative laminatiion on both sides flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete all as specified and directed.
S&F M.S Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S&F PVC coloured vertical blind / roller blind hanging on powder coated hanging arrangement including roller and all necessry fixing and fetures as per manufacture instruction. or directed by GE complete all as specified and directed after taking down old one.
M&L for Dismantling of wall and ceiling boards any thickness including cover fillets complete all as specified and directed.
M&L for 5 mm thick Solid PVC wall Lining/panelling printed colour PVC sheet in strips & channel feathered at the edges for fixing on Solid PVC Wall Lining, Insulated PVC Wall Lining, and Solid PVC Partitions inclusive of Solvent Cement and fixing at site. complete all as specified and directed.
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness complete all as specified and directed.
Providing 0.63mm thick corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. complete all as specified and directed.
Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete all as specified and directed.
Providing valleys of 90 cm wide overall in 1.00 mm thick with zinc coating not less than 275 gm/m2 plain G.S. sheet fixed with polymer coated J, or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete all as specified and directed.
Supply only Liquid water proofing compound ISI Marked (used 200 ml per bag of cement) complete all as specified and directed.
Taking down of carefully unserviceable Aluminium/copper point wiring (light, fan socket or power) complete with fitting such as switches, ceiling rose lamp holder, sockets, fan regulators, SK/FTL light fittings etc removing materials for store for keeping in safe custody or for taking credit (credit for above items should be taken as per conditions separately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, concealed conduit wiring in walls and surface with GI saddles GI screws, rawal plugs in ceiling or roof if not possible including Tee, Junction boxes and provision of flush metal boxes, inner and outer plate suitable for modular switch, socket and fan regulator as per site requirement and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly ccomplete all as specified and directed. for one light/Fan point controlled by one Switch.
All as per Srl item No 61 above for point wiring for 5 pin switch socket outlet, 5/6 Amps on same board with other switches complete all as specified and directed.
All as per Srl item No 61 above for point wiring for 5 pin switch socket outlet, 5/6 Amps on independent board complete all as specified and directed.
All as per item No 61 above for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area)cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete all as specified and directed.
S&F Modular switch single pole one way 6 amp complete all as specified and directed.
S&F Modular switch single pole one way 16 amp complete all as specified and directed.
S&F Modular socket outlet 2/3 pin combined 2 module 6/16 amp complete all as specified and directed.
S&F Modular socket outlet 2/3 pin combined 2 module 6 amp complete all as specified and directed.
S&F ceiling rose 3 plates polycarbonate, isolated body complete all as specified and directed.
S&F modular fan step regulator 120 W 2 module complete all as specified and directed.
S&F MCB distribution board powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100/63 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with rating DB 8 Way 240 volt single door complete all as specified and directed.
Supply and fixing MCB SPN 240 volts 'C' Curve suitable for fixing in DB of capacity 63 Amps complete all as specified and directed.
Supply and fixing MCB SP 240 volts 'C' Curve suitable for fixing in existing DBs of capacity 6 to 32 Amps complete all as specified and directed.
Supplying, fixing & testing in replacement UNSV recess mounting in built ,36 Watts,2'x2' LED ceiling light fitting with slim line extruded aluminium/ CRCA body, opal acrylic diffuser, electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed.
Supply and install hi wall Inverter split units indoor/outdoor hot and cool complete with cordless remote control unit and with in built air ionises and plasma filter for better indoor air quality with 3 star rating and EER 3.2 of capacity 2.0 TR complete all as specified and directed. Make:Carrier/ Voltas/Blue star / Dakin/ Hitachi
Supply and install hi wall Inverter split units indoor/outdoor hot and cool complete with cordless remote control unit and with in built air ionises and plasma filter for better indoor air quality with 3 star rating and EER 3.2 of capacity 1.5 TR complete all as specified and directed. Make:Carrier/ Voltas/Blue star / Dakin/ Hitachi
S&F VTPN DB enclosure with vertical type load line distribution board ,double door, 4 way, AC 3 Phase 415 volt with TPN bus bar 250 Amps for each phase with 2 Neutral bar, 2 Earthbar and cable ties for cable management,fully insulted busbar & shrouded Neural bars ,improved Pan assembly for each insullation ,prefitted masking sheeet,reversible door for IP 43-"IK 09 with metal door with provision for DPX3 160 MCCB as incomer and SP/TP MCB's as out going complete all as specified and directed.
Supply and fix MCCB 4 pole,200 Amps 415 volts, 25 Hz having breaking capacity 36 KA , with thermal magnetic protection unit for existing LT panel and testing complete all as specified and directed.
S&F for submain wiring alongwith earth continuity conductor with PVC insulated FR multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) in PVC conduit drawing into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour along with accessories of following nominal size:-
M&L for sub main wiring with sub main wiring PVC insulated, unsheathed stranded copper conductor cable of size 4x16 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 25 mm dia with standard accessories along-with PVC(green colour) insulated , unsheathed, stranded copper conductor of size 2x16 Sqmm as earth continuity conductor complete all as specified and directed. Note:-Four run of single core PVC cable with two run of earth conductor and conduit shall be measured as one unit.
M&L for sub main wiring with sub main wiring PVC insulated, unsheathed stranded copper conductor cable of size 2x10 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 25 mm dia with standard accessories along-with PVC(green colour) insulated , unsheathed, stranded copper conductor of size 1x 10 Sqmm as earth continuity conductor complete all as specified and directed. Note:-Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
M&L for sub main wiring with sub main wiring PVC insulated, unsheathed stranded copper conductor cable of size 2x6 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 25 mm dia with standard accessories along-with PVC(green colour) insulated , unsheathed, stranded copper conductor of size 1x 6 Sqmm as earth continuity conductor complete all as specified and directed. Note:-Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
M&L for sub main wiring with sub main wiring PVC insulated, unsheathed stranded copper conductor cable of size 2x4 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 25 mm dia with standard accessories along-with PVC(green colour) insulated , unsheathed, stranded copper conductor of size 1x4 Sqmm as earth continuity conductor complete all as specified and directed. (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. Notes ser item No 80 to 83:- (ii) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement sand mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling/RCC surfaces shall be in surface conduit of suitable size fixed on ceiling/RCC surfaces with using PVC rawl plugs.
S&F SPN plug and socket enclosure with Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole and neutral MCB 20 amp, 240 Volts power coated CRCA steel sheet enclosure recess mounted with chained metal cover for the socket outlet with and including one number single pole 'C' series MCB 16/20 amp complete all as specified and directed.
OM TRADERS
M/S VIJAY TRADERS
M/S DHYANI CONSTRUCTION CO.
SANJEEV CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .