GEMC-511687744330575
Awarded to ANALYTICAL TECHNOLOGIES LIMITED
₹1.9 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| UV VIS SPECTROPHOTOMETER | UV VIS 3120 | - | 1 NOS | ₹1.9 L | 190,000 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.9 LQualified Make: ANALYTICAL
Model: UV VIS 3120 ANALYTICAL HOUSE E67 E68 RAVI PARK VASNA ROAD BARODA GUJARAT 390 015 | BARODA | VADODARA | GUJARAT | 390015 | Make: ANALYTICAL
Model: UV VIS 3120 | ₹1.9 L | L1 | Qualified |
| 2 | L2₹2.3 L+₹42,000 (22.1%)Qualified Make: ANALYTICAL
Model: UV VIS 3120 23 BAJRANG VIHAR CHAPOLA KI DHANI SANGANER JAIPUR RAJASTHAN 302029 | JAIPUR | RAJASTHAN | 302029 | Make: ANALYTICAL
Model: UV VIS 3120 | ₹2.3 L+₹42,000 (22.1%) | L2 | Qualified |
| 3 | Disqualified Make: Labtronics
Model: LABTRONICS LT2203 MADHOKUNJ ALLAHABAD UTTAR PRADESH 211002 | PRAYAGRAJ | UTTAR PRADESH | 211002 | Make: Labtronics
Model: LABTRONICS LT2203 | - | - | Disqualified |
| 4 | Disqualified Make: AARSON
Model: RSCH-367 9 10 KHOJKI PUR P O INDUSTRIAL ESTATE AMBALA HARYANA 133001 INDIA | AMBALA | HARYANA | 133001 | Make: AARSON
Model: RSCH-367 | - | - | Disqualified |
| 5 | Disqualified Make: BIOGENIX
Model: BS-900 INDIA | Make: BIOGENIX
Model: BS-900 | - | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
11 Aug 2018, 5:00 pmClosed
SPECTROPHOTOMETER SPECTROPHOTOMETER ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values TYPE Type of Spectrophotometer UV - VISIBLE UV - VISIBLE
VISIBLE
UV - VISIBLE - IR Type of Optical System Double Beam Single Beam
Split Beam
Double Beam Monochromator Type Holographic Grating Reflexive Grating
Holographic Grating
Czerny-turner
NA Detector Type Photodiode Photo Multiplier Tube (PMT)
Photodiode
CMOS
Diode array Spectral Bandwidth Type Variable Bandwidth Fixed Bandwidth
Variable Bandwidth LIGHT SOURCE Light Source Deuterium Lamp
Tungsten Halogen Lamp Halogen Lamp
Deuterium Lamp
LED
Tungsten Halogen Lamp
Xenon Flash Diffraction Grating (lines/mm) 1200 600
800
1000
1200
1400
1600
1800 Switching of Light Source Automatic Automatic
Mannual Wavelength Setting And Scanning Automatic Automatic
Mannual OPTICAL PERFORMANCE Source Wavelength - Minimum 190 175
180
185
190
195
200
320
340 1/5 Source Wavelength - Maximum 1500 As per GeM Catalogue. Higher is better Resolution 0.3 0.002
0.3
0.5
1
1.25
1.5
1.7
2 Wavelength Accuracy (+/-) 0.3 0.1
0.8
2
2.5 Bandwidth (nm) 0.5
2.0
4.0 0.1
0.2
1.8
4.0
5.0
0 to 5.0 If variable band width
Specify the incremental step value(mm) NA - Scanning Speed (nm/min) 500 - Focal length (mm) 300 and above 0 to 49
50 to 99
100 to 149
150 to 199
200 to 249
250 to 299
300 and above Photometric measurement modes Transmittance
Absorba nce
Concentration (Wavelength
time) Transmittance
Absorbance
time)
Reflectance
Energy
Polarisation Photometric Absorbance (Max) (Abs) (+/-) 3 Photometric Absorbance Accuracy (Max) (+/-) 0.3 Photometric Transmittance (Max) (+/-) 100 Photometric Transmittance Accuracy (Max) (+/-) 0.3 Photometric Reflectance (Max) (+/-) 0.2 Photometric Reflectance Accuracy (Max) (+/-) 0.2 - Stray Light Correction Automatic - Baseline Correction Automatic - GENERIC Display In-built display In-built display
Through PC Display type LCD with Backlight LCD with Backlight
LCD touchscreen
TFT
NA 2/5 Display Size 4 Test result printing Through external printer Through inbuilt Printer
Through external printer If inbuilt printer
Type of printer N/A Thermal printer
Dot matrix
Laser b/w
Inkjet b/w
Color laser
Color inkjet
N/A Suitable software for connecting PC & Printer Yes - Connectivity USB
RS 232 - Internal storage(GB) 0 Sample switching/selection Automatic - Capacity of Sample holder/Sample Carousel 8 - Mximum Path Length of sample 10 Number of Cuvettes supplied 10 10
25
50
100
300
400
500 Power Supply 230 V ± 10
50 Hz - Any other features/accesories covered in scope of supply - - Spares and Consumables inclusive in the scope of supply true true
false List of Items and Quantity of each item included in the offer - - OPERATING CONDITIONS Minimum Operating Temperature 10 -5
10
0
5
10 Maximum Operating Temperature 45 35
40
45
55
60 Operating Humidity (RH) (%) at 40 degree C 80 80
85
90
95 WARRANTY Onsite Warranty 1 1
3
4
5 Availability of Spares (at extra cost) 10 2
6
7
8
10 Certification Availability of UL/CE Certification as per EN 61010-1:2010 Yes Yes
No 3/5 Safety requirements for electrical equipment for measurement
control
and laboratory use General requirements Conformance to EMC/EMI as per EN 61326-1:2013 Electrical equipment for measurement
control and laboratory use Yes Yes
No Availability of Test Reports from Central Govt/NABL approved/ILAC acredited lab to prove conformity to the specification Yes Yes
No If yes test report to furnished
to the buyer on demand Yes - Test Report number and date - - Name and address of the Lab - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Pratima Srivastav 324001
JDB govt girls college
Nayapura Kota 1 15
448099
GEM/2018/B/63352
GeM Contract
SPECTROPHOTOMETER
GeM Contract
15 days
Rajasthan; Kota
PRODUCT
Awarded to ANALYTICAL TECHNOLOGIES LIMITED
₹1.9 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| UV VIS SPECTROPHOTOMETER | UV VIS 3120 | - | 1 NOS | ₹1.9 L | 190,000 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| SPECTROPHOTOMETER SPECTROPHOTOMETER ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values TYPE Type of Spectrophotometer UV - VISIBLE UV - VISIBLE | - | - | - |
| VISIBLE | - | - | - |
| UV - VISIBLE - IR Type of Optical System Double Beam Single Beam | - | - | - |
| Split Beam | - | - | - |
| Double Beam Monochromator Type Holographic Grating Reflexive Grating | - | - | - |
| Holographic Grating | - | - | - |
| Czerny-turner | - | - | - |
| NA Detector Type Photodiode Photo Multiplier Tube (PMT) | - | - | - |
| Photodiode | - | - | - |
| CMOS | - | - | - |
| Diode array Spectral Bandwidth Type Variable Bandwidth Fixed Bandwidth | - | - | - |
| Variable Bandwidth LIGHT SOURCE Light Source Deuterium Lamp | - | - | - |
| Tungsten Halogen Lamp Halogen Lamp | - | - | - |
| Deuterium Lamp | - | - | - |
| LED | - | - | - |
| Tungsten Halogen Lamp | - | - | - |
| Xenon Flash Diffraction Grating (lines/mm) 1200 600 | - | - | - |
| 800 | - | - | - |
| 1000 | - | - | - |
| 1200 | - | - | - |
| 1400 | - | - | - |
| 1600 | - | - | - |
| 1800 Switching of Light Source Automatic Automatic | - | - | - |
| Mannual Wavelength Setting And Scanning Automatic Automatic | - | - | - |
| Mannual OPTICAL PERFORMANCE Source Wavelength - Minimum 190 175 | - | - | - |
| 180 | - | - | - |
| 185 | - | - | - |
| 190 | - | - | - |
| 195 | - | - | - |
| 200 | - | - | - |
| 320 | - | - | - |
| 340 1/5 Source Wavelength - Maximum 1500 As per GeM Catalogue. Higher is better Resolution 0.3 0.002 | - | - | - |
| 0.3 | - | - | - |
| 0.5 | - | - | - |
| 1 | - | - | - |
| 1.25 | - | - | - |
| 1.5 | - | - | - |
| 1.7 | - | - | - |
| 2 Wavelength Accuracy (+/-) 0.3 0.1 | - | - | - |
| 0.8 | - | - | - |
| 2 | - | - | - |
| 2.5 Bandwidth (nm) 0.5 | - | - | - |
| 2.0 | - | - | - |
| 4.0 0.1 | - | - | - |
| 0.2 | - | - | - |
| 1.8 | - | - | - |
| 4.0 | - | - | - |
| 5.0 | - | - | - |
| 0 to 5.0 If variable band width | - | - | - |
| Specify the incremental step value(mm) NA - Scanning Speed (nm/min) 500 - Focal length (mm) 300 and above 0 to 49 | - | - | - |
| 50 to 99 | - | - | - |
| 100 to 149 | - | - | - |
| 150 to 199 | - | - | - |
| 200 to 249 | - | - | - |
| 250 to 299 | - | - | - |
| 300 and above Photometric measurement modes Transmittance | - | - | - |
| Absorba nce | - | - | - |
| Concentration (Wavelength | - | - | - |
| time) Transmittance | - | - | - |
| Absorbance | - | - | - |
| time) | - | - | - |
| Reflectance | - | - | - |
| Energy | - | - | - |
| Polarisation Photometric Absorbance (Max) (Abs) (+/-) 3 Photometric Absorbance Accuracy (Max) (+/-) 0.3 Photometric Transmittance (Max) (+/-) 100 Photometric Transmittance Accuracy (Max) (+/-) 0.3 Photometric Reflectance (Max) (+/-) 0.2 Photometric Reflectance Accuracy (Max) (+/-) 0.2 - Stray Light Correction Automatic - Baseline Correction Automatic - GENERIC Display In-built display In-built display | - | - | - |
| Through PC Display type LCD with Backlight LCD with Backlight | - | - | - |
| LCD touchscreen | - | - | - |
| TFT | - | - | - |
| NA 2/5 Display Size 4 Test result printing Through external printer Through inbuilt Printer | - | - | - |
| Through external printer If inbuilt printer | - | - | - |
| Type of printer N/A Thermal printer | - | - | - |
| Dot matrix | - | - | - |
| Laser b/w | - | - | - |
| Inkjet b/w | - | - | - |
| Color laser | - | - | - |
| Color inkjet | - | - | - |
| N/A Suitable software for connecting PC & Printer Yes - Connectivity USB | - | - | - |
| RS 232 - Internal storage(GB) 0 Sample switching/selection Automatic - Capacity of Sample holder/Sample Carousel 8 - Mximum Path Length of sample 10 Number of Cuvettes supplied 10 10 | - | - | - |
| 25 | - | - | - |
| 50 | - | - | - |
| 100 | - | - | - |
| 300 | - | - | - |
| 400 | - | - | - |
| 500 Power Supply 230 V ± 10 | - | - | - |
| 50 Hz - Any other features/accesories covered in scope of supply - - Spares and Consumables inclusive in the scope of supply true true | - | - | - |
| false List of Items and Quantity of each item included in the offer - - OPERATING CONDITIONS Minimum Operating Temperature 10 -5 | - | - | - |
| 10 | - | - | - |
| 0 | - | - | - |
| 5 | - | - | - |
| 10 Maximum Operating Temperature 45 35 | - | - | - |
| 40 | - | - | - |
| 45 | - | - | - |
| 55 | - | - | - |
| 60 Operating Humidity (RH) (%) at 40 degree C 80 80 | - | - | - |
| 85 | - | - | - |
| 90 | - | - | - |
| 95 WARRANTY Onsite Warranty 1 1 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 5 Availability of Spares (at extra cost) 10 2 | - | - | - |
| 6 | - | - | - |
| 7 | - | - | - |
| 8 | - | - | - |
| 10 Certification Availability of UL/CE Certification as per EN 61010-1:2010 Yes Yes | - | - | - |
| No 3/5 Safety requirements for electrical equipment for measurement | - | - | - |
| control | - | - | - |
| and laboratory use General requirements Conformance to EMC/EMI as per EN 61326-1:2013 Electrical equipment for measurement | - | - | - |
| control and laboratory use Yes Yes | - | - | - |
| No Availability of Test Reports from Central Govt/NABL approved/ILAC acredited lab to prove conformity to the specification Yes Yes | - | - | - |
| No If yes test report to furnished | - | - | - |
| to the buyer on demand Yes - Test Report number and date - - Name and address of the Lab - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Pratima Srivastav 324001 | - | - | - |
| JDB govt girls college | - | - | - |
| Nayapura Kota 1 15 | - | - | - |
Exempted
14 Aug 2018
8 Aug 2018
contract_GEMC-511687744330575.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_448099.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .