| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 LAccepted-AOC A 178 OLD NO 525 KH NO 2 18 G F BLOCK A PREHLAD VIHAR GUPTA COLONY VILL PRAHLAD PUR DELHI 110042 | NORTH WEST | DELHI | 110042 | L1 | Accepted-AOC Being L1 Accepted and awarded the bid. | |
| 2 | L2₹9.5 L+₹1.6 L (19.5%)Rejected-AOC | L2 | Rejected-AOC Being L2 rejected. | |
| 3 | L3₹9.8 L+₹1.8 L (22.3%)Rejected-AOC 96 BHAGAT SINGH MARKET GOLE MARKET NEW DELHI 110001 | NEW DELHI | DELHI | 110001 | L3 | Rejected-AOC Being L3 rejected. | |
| 4 | L4₹10.6 L+₹2.7 L (33.2%)Rejected-AOC A 6 MANDAWALI UNCHEPAR DELHI 110092 | SHAHDARA | DELHI | 110092 | L4 | Rejected-AOC Being L4 rejected. |
Tender Value
₹10.9 L
EMD Value
₹21,810
Closing Date
31 Dec 2024, 3:00 pmClosed
Executive Engineer (ED-II)
TC Building Wazirpur IA Delhi
Operation and Maintenance of Pump House and Goods Lift with Internal Wiring of each passage block at FFC Jhandewalan complex, Delhi
2024_DSIDC_267226_1
02/2024-25
Open Tender
Electrical Works
Item Rate
365 days
FFC Jhandewalan Delhi
Please refer Tender documents.
15 documents required · 15 mandatory
₹0
₹21,810
6 Jan 2025
25 Dec 2024
31 Dec 2024
25 Dec 2024
31 Dec 2024
25 Dec 2024
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required
Group C
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator
6 way, Double door
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
Single pole
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single corecable etc. as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required
2 X 6 sq. mm (19mm)
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Operation of Pump sets & Goods Lift all days including Sundays & holidays by providing servises of qualified & experienced skilled staff as reqd. at site or as per the direction of Engineer-In-Charge.
Cleaning of pump room alongwith all the electrical installed equipment all days including Sundays & holidays by providing servises of Un-skilled staff as reqd. at site or as per the direction of Engineer-In-Charge.
Refilling and Testing of Fire Extinguisher cylinder (upto 5 KG Capacity) as per IS Code:2190 complete as required at site.
ABC Type
CO2 Type
Supply of 1x20 watt LED tube light Indoor Decorative LED extruded Aluminium batten in aluminium. Length-1210mm, Anosised finish with Opal diffuser IP-20 tube light complete accessories in all respect.
Supply of 1200mm sweep AC electric ceiliing fan, capacitor type double ball bearing complete with 300 mm down rod suitable for operation on 230/240Volts, 50 Hz, Single phase, AC supply at site.
SDV ENGINEERING ASSOCIATES (P) Ltd (BID ID -1556431)
R.K. Jain and Sons Hospitality Services Pvt. Ltd. (BID ID -1556311)
PARASAR ELECTRICALS & REFRIGERATION (BID ID -1556312)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .