Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹53.9 LAccepted-AOC EBENEZER C C33 1185A CHALIKAVATTOM VENNALA P O KOCHI KERALA 682 028 | ERNAKULAM | KERALA | 682028 | ₹53.9 L Quoted ₹56.1 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹56.9 LRejected-AOC 42 608A PULLOMPARAMBIL HOUSE MANDAKARA ROAD KOCHI 682 018 | ERNAKULAM | KERALA | 682018 | ₹56.9 L | L2 | Rejected-AOC Rejected |
| 3 | L3₹57.9 LRejected-AOC 26 2579 THEVARA PO KOCHI ERNAKULAM KERALA 682013 | KOCHI | ERNAKULAM | KERALA | 682013 | ₹57.9 L | L3 | Rejected-AOC Rejected |
| 4 | L4₹58.3 LRejected-AOC DOOR NO 6 1 JOTHI NAGAR 6TH STREET VARATHARAJAPURAM UPPLIPALAYAM PO COIMBATORE 641015 | COIMBATORE | COIMBATORE | TAMIL NADU | 641015 | ₹58.3 L | L4 | Rejected-AOC Rejected |
| 5 | L5₹63.9 LRejected-AOC 20 2169 PALLURTH PO ERNAKULUM KERALA 682006 | ERNAKULAM | KERALA | 682006 | ₹63.9 L | L5 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | AMRITH ENGINEERS L7 | AR Traders L3 | WELTRONENGINEERINGSERVICES L2 | Powertech Engineers L1 | Jack Electrolinks Private Limited L5 | PRIYA ENTERPRISES L4 | ELAN ENGINEERS L6 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M & L for B- Check Servicing and cleaning of DG set of capacity up to 50 KVA complete all as specified and directed by Engineer-in-Charge. | 24 | Each Job | 5,000 ₹1.2 L | 1,800 ₹43,200 | 3,500.99 ₹84,023.76 | 5,250 ₹1.3 L | 2,650 ₹63,600 | 800 ₹19,200 | 5,000.99 ₹1.2 L |
| 2.00 | M & L for B- Check Servicing and cleaning of DG set of capacity 60 to 82.50 KVA complete all as specified and directed by Engineer-in-Charge. | 12 | Each Job | 6,000 ₹72,000 | 3,000 ₹36,000 | 4,000 ₹48,000 | 6,250 ₹75,000 | 3,500 ₹42,000 | 1,200 ₹14,400 | 5,500.99 ₹66,011.88 |
| 3.00 | M & L for B- Check Servicing and cleaning of DG set of capacity 100 to 160 KVA complete all as specified and directed by Engineer-in-Charge. | 16 | Each Job | 7,000 ₹1.1 L | 4,000 ₹64,000 | 4,500 ₹72,000 | 7,250 ₹1.2 L | 3,850 ₹61,600 | 1,500 ₹24,000 | 6,000.99 ₹96,015.84 |
| 4.00 | M & L for B- Check Servicing and cleaning of DG set of capacity 200 to 250 KVA complete all as specified and directed by Engineer-in-Charge. | 14 | Each Job | 8,000 ₹1.1 L | 6,500 ₹91,000 | 5,000 ₹70,000 | 8,250 ₹1.2 L | 3,850 ₹53,900 | 2,000 ₹28,000 | 7,000.99 ₹98,013.86 |
| 5.00 | M & L for B- Check Servicing and cleaning of DG set of capacity 320 to 437.5 KVA complete all as specified and directed by Engineer-in-Charge. | 5 | Each Job | 9,000 ₹45,000 | 12,000 ₹60,000 | 6,000.99 ₹30,004.95 | 9,000 ₹45,000 | 4,500 ₹22,500 | 4,000 ₹20,000 | 9,000.99 ₹45,004.95 |
| 6.00 | M & L for B- Check Servicing and cleaning of DG set of capacity 500 KVA complete all as specified and directed by Engineer-in-Charge. The 'B' Check should be carried out through authorised dealer of OEM | 4 | Each Job | 24,500 ₹98,000 | 45,000 ₹1.8 L | 10,000.99 ₹40,003.96 | 17,500 ₹70,000 | 5,500 ₹22,000 | 4,500 ₹18,000 | 19,000.99 ₹76,003.96 |
| 7.00 | M & L for B- Check Servicing and cleaning of DG set of capacity 625 KVA complete all as specified and directed by Engineer-in-Charge.The'B' Check should be carried out through authorised dealer of OEM | 4 | Each Job | 32,000 ₹1.3 L | 70,000 ₹2.8 L | 20,000.99 ₹80,003.96 | 25,000 ₹1 L | 6,500 ₹26,000 | 4,500 ₹18,000 | 33,000.99 ₹1.3 L |
| 8.00 | M & L for B- Check Servicing and cleaning of DG set of capacity 810 KVA complete all as specified and directed by Engineer-in-Charge.The 'B' Check should be carried out through authorised dealer of OEM | 2 | Each Job | 45,000 ₹90,000 | 88,000 ₹1.8 L | 25,000.99 ₹50,001.98 | 35,000 ₹70,000 | 8,500 ₹17,000 | 5,000 ₹10,000 | 40,000 ₹80,000 |
| 8.10Scope of work for item No. 1 to 8 shall be as under :- (a) Draining out unserviceable engine oil from engine, refill with new oil. (b) Cleaning all sludge/deposits in the oil sump and removal of dust deposited on DG set and its surroundings. (c) Replacing the primary, secondary and bye-pass fuel filters. (d) Replacing oil filters. (e) Cleaning of air filters (f) Replace unserviceable PVC fuel indication tube (g) Checking of battery terminals and chrochodoile clamp at site, (h) Supply and replacing unserviceable "D" clamp, nut bolt, washers, etc. (j) Checking of fan belt all nut bolt, etc (l) Top up the engine oil, radiator coolent and distilled water. (m) Tools for the repairs and safety of the mechanic/engineer shall be at contractor's risk. (n) Refill/ Top up the destiled water in the battery if required. (o) Cleaning the radiator by using water blower/vacuume cleaner. (p) Checking of anti-vibration pad and replace with new one if required. Note :- (i) Distilled water, Engine oil and radiater coolent if any will be measured and paid separately. (ii) All spares and parts used other than mentioned above shall be measured and paid separately and all spares shall be recommended by manufacturer of the respective DG set and shall be purchased from authorised dealer of OEM. (iii) Servicing of DG Set 500 and above should be carried out through authorised dealer of OEM ie, manufacturer of the respective DG Set (Kirloskar/Catter Piller/Cummins/Ashok Leyland/Powerica, Greaves). | ||||||||||
| 9.00 | Supply and fix in replacement Radiator coolent coil suitable for DG set up to 50 kVA as per existing make & model complete all as specified. | 8 | Each Job | 8,000 ₹64,000 | 7,500 ₹60,000 | 4,500.99 ₹36,007.92 | 14,000 ₹1.1 L | 3,500 ₹28,000 | 1,500 ₹12,000 | 7,000.99 ₹56,007.92 |
Updated dates
Tender Value
₹68.9 L
EMD Value
₹1.3 L
Closing Date
21 Nov 2025, 6:00 pmClosed
Shri RK Singh IDSE CWE(NW) Kochi
CWE(NW) Kochi
REPAIR/MAINT/SERVICING OF DG SETS, DG PANELS, AMF PANELS AND CONNECTED LT ELECTRIC SYSTEM INCLUDING REPLACEMENT OF ELECTRICAL FITTINGS AND FIXTURES ALONGWITH PAINTING WORK IN AREAS OF KATARIBAGH, NAY, SFNA, 33 WEU, MOK, GARUDA, HQ SNC, NSRY, MOC, SAN
2025_MES_735935_1
CWE(NW)KOCHI/81609
Open Tender
Civil Works
270 days
Kochi
As per NIT
7 documents required · 7 mandatory
₹1,000
GE(NS) Kochi
₹1.3 L
Yes
10 Jan 2026
17 Oct 2025
24 Nov 2025
17 Oct 2025
21 Nov 2025
7 Nov 2025
Amount
M & L for B- Check Servicing and cleaning of DG set of capacity up to 50 KVA complete all as specified and directed by Engineer-in-Charge.
M & L for B- Check Servicing and cleaning of DG set of capacity 60 to 82.50 KVA complete all as specified and directed by Engineer-in-Charge.
M & L for B- Check Servicing and cleaning of DG set of capacity 100 to 160 KVA complete all as specified and directed by Engineer-in-Charge.
M & L for B- Check Servicing and cleaning of DG set of capacity 200 to 250 KVA complete all as specified and directed by Engineer-in-Charge.
M & L for B- Check Servicing and cleaning of DG set of capacity 320 to 437.5 KVA complete all as specified and directed by Engineer-in-Charge.
M & L for B- Check Servicing and cleaning of DG set of capacity 500 KVA complete all as specified and directed by Engineer-in-Charge. The 'B' Check should be carried out through authorised dealer of OEM
M & L for B- Check Servicing and cleaning of DG set of capacity 625 KVA complete all as specified and directed by Engineer-in-Charge.The'B' Check should be carried out through authorised dealer of OEM
M & L for B- Check Servicing and cleaning of DG set of capacity 810 KVA complete all as specified and directed by Engineer-in-Charge.The 'B' Check should be carried out through authorised dealer of OEM
Scope of work for item No. 1 to 8 shall be as under :- (a) Draining out unserviceable engine oil from engine, refill with new oil. (b) Cleaning all sludge/deposits in the oil sump and removal of dust deposited on DG set and its surroundings. (c) Replacing the primary, secondary and bye-pass fuel filters. (d) Replacing oil filters. (e) Cleaning of air filters (f) Replace unserviceable PVC fuel indication tube (g) Checking of battery terminals and chrochodoile clamp at site, (h) Supply and replacing unserviceable "D" clamp, nut bolt, washers, etc. (j) Checking of fan belt all nut bolt, etc (l) Top up the engine oil, radiator coolent and distilled water. (m) Tools for the repairs and safety of the mechanic/engineer shall be at contractor's risk. (n) Refill/ Top up the destiled water in the battery if required. (o) Cleaning the radiator by using water blower/vacuume cleaner. (p) Checking of anti-vibration pad and replace with new one if required. Note :- (i) Distilled water, Engine oil and radiater coolent if any will be measured and paid separately. (ii) All spares and parts used other than mentioned above shall be measured and paid separately and all spares shall be recommended by manufacturer of the respective DG set and shall be purchased from authorised dealer of OEM. (iii) Servicing of DG Set 500 and above should be carried out through authorised dealer of OEM ie, manufacturer of the respective DG Set (Kirloskar/Catter Piller/Cummins/Ashok Leyland/Powerica, Greaves).
Supply and fix in replacement Radiator coolent coil suitable for DG set up to 50 kVA as per existing make & model complete all as specified.
All asper item No 9 but DG Set 60 to 200 KVA capacity
All as per item No 9 but DG Set 250 to 320 KVA capacity
All as per item No 9 but DG Set 500 to 810 KVA capacity
M & L Servicing radiator assembly of DG Set upto 50 KVA capacity by removing the radiator from its base, taken to workshop, opening into parts, sort out and replace unserviceable items, cleaning the channels, cooling coils, repairs to blocked fins including necessary gas welding works, removing dust by using hot blower, reassembling and refitting the radiator on its original base including transportation of radiator from work shop to site complete all as per the direction of the Engr-in-Charge.
All asper item No 13 but DG Set 60 to 82.50 KVA capacity
All as per item No 13 but DG Set 100 to 200 KVA capacity
All as per item No 13 but DG Set 250 to 437.50 KVA capacity
All as per item No 13 but DG Set 500 to 625 KVA capacity
S & F in repair Solonoid coil suitable for DG Set 500 to 625 KVA capacity as per existing type and model complete all as specified.
S & F in repair Solonoid coil suitable for DG Set 200 to 437.50 KVA capacity as per existing type and model complete all as specified.
S & F in repair Solonoid coil suitable for DG Set 40 to 160 KVA capacity as per existing type and model complete all as specified.
S & F in repair Filter assembly suitable for DG Set upto 250 KVA capacity as per existing type and model complete all as specified.
S & F in repair Filter assembly suitable for DG Set 125 to 320 KVA capacity as per existing type and model complete all as specified.
S & F in repair Filter assembly suitable for DG Set 400 to 625 KVA capacity as per existing type and model complete all as specified.
M & L Taking down water pump assembly of DG sets upto 62.5 KVA capacity from its existing position, opening into parts, overhauling the same at workshop with replacement of water pump repair kit, ball bearing (1No) (Make SKF/NBC), gasket seal, oil seal and re-assembling and re-fixing on the base including to and fro conveyance charge from site to workshop and back complete all as specified.
All as per item No 24 but water pump assembly of DG sets 75 to 160 KVA capacity
All as per item No 24 but water pump assembly of DG sets 200 to 625 KVA capacity
M & L Dismantling carefully fuel injection pump (FIP) upto 6 cylinders engine of DG set and transporting to workshop, opening into parts, for maintenance, servicing, overhauling, tuning and calibration , adjustment of nozzle pressure and other controls, replacement of unserviceable spares, re-assembling, re-fixing the FIP on its original position including to and from conveyance charge from site to workshop and back complete all as specified.
All as per item No 27 here-in-above but fuel injection pump (FIP) upto 12 cylinders engine of DG set, complete all as specified.
M & L Taking down 24 volt self starter assembly of DG set, from the existing position, and transporting to workshop, opening in to parts, sort out the unserviceable items like carbon bush, pinion, armature, carbon brush holder, etc. and replace the same with new one including rewinding of field coils, re-assembling and re-fixing the same in its original position, testing with entire satisfaction of Enfineer-in-Charge including to and fro conveyance charge from site to workshop and back complete all as specified.
All as per item No 29 here-in-above but 12 volt self starter assembly of DG set, complete all as specified.
Supply and fix inreplacement Hose Pipe Set with clamps suitable for 20 KVA to 125 KVA capacity DG sets as per existing type and size complete all as specified.
Supply and fix in replacement Hose Pipe Set with clamps suitable for 150 KVA to 320 KVA capacity DG sets as per existing type and size complete all as specified.
Supply and fix in replacement Hose Pipe Set with clamps suitable for 400 KVA to 625 KVA capacity DG sets as per existing type and size complete all as specified.
M & L Dismantling the alternator of DG set of capacity 20 kVA to 62.5 kVA from its base by using chain and pulley after removing the coupling with the engine, removing all nut, bolt with washer and all electrical connections of the alternator, shifting the alternator to work shop by crane and vehicle, opening into parts, checking all winding like main stator/rotor winding, exciter stator/rotor winding. Rewinding the main rotor and exciter rotor by using the "F" class insulation and existing gauge and type of magnet wire which was on the original motor, varnishing, heating, drying, greasing the bearings including replacement of unserviceable bearings, Re-fixing the complete including connection to the terminal box of the alternator at work shop and shifting the same to the site, Fixing the alternator to its base carefully by using chain and pulley, connecting it with existing engine including checking the alignment of alternator with the engine, connecting all electrical connections of the alternator and testing the DG set on "OFF/FULL LOAD", matching to the existing range of RPM of the engine out put voltage 415 volt and testing complete all as per the direction of the Engr-in-charge.
All as per Item No-35 but DG Set capacity 62.5 KVA to 100 KVA capacity complete all as specified
All as per Item No-35 but DG Set capacity 160 KVA to 200 KVA capacity complete all as specified
All as per Item No-35 but DG Set capacity 200 KVA to 320 KVA capacity complete all as specified
All as per Item No-35 but DG Set capacity 320 KVA to 625 KVA capacity complete all as specified
M & L Preparing surfaces of DG set canopy/complete body/LT panel board and applying painting two coats of superior quality synthetic enamel paint using spray gun including sticker work and writing of incoming/outgoing feeder with letters, MES/SM Nos etc complete all as specified and directed by Engineer-in-Charge.
M & L Taking down unserviceable heat insulation from exhaust piping and providing new heat insulation to exhaust pape using 50 mm thick mineral wool inside the container & upto the exhaust stack. The insulation shall be cladded/ covered with 24G aluminium sheet. Pipe length shall be maximum up to 12 Mtr long from engine including necessary welding works, cladding works with wire mesh and aluminium foil, replace unserviceable supporting MC, angle iron 50 mm X 50 mm X 6 mm , suitable size flange, nut, bolt and washers as required including weather cowl complete all as specified.
M & L Dismantling exhaust manifold from the engine, detect the smoke leak, clean the manifold including welding works, replacement of unserviceable spares, packing, bellows, nut, bolt, washers, insulators, etc. reassembling and refixing on its base, testing by running the DG set NO LOAD/FULL LOAD complete all as specified.
Attending any electrical or mechanical complaints of DG set up to 50 KVA capacity including AMF panel and rectifying with spare parts, if it minor nature such as nuts, bolts, washers etc, where no major spares are required and suggesting remedial measures if major complaints complete all as secified.
All as per item No 39 here-in-above but DG Set of 60 to 160 KVA capacity complete all as secified.
All as per item No 39 here-in-above but DG Set of 200 to 320 KVA capacity complete all as secified.
All as per item No 39 here-in-above but DG Set of 400 to 625 KVA capacity complete all as secified.
All as per item No 39 here-in-above but DG Set above 810 KVA capacity complete all as secified.
NOTE FOR ITEM NO.39 TO 43 :- (i) The Mechanic/Engineer shal attend the complaints with in 48 hrs from the tele message/call from the Engineer-in-Charge or JE including Sunday and holiday. (ii) The rate quoted deem to include the cost of minor spares such as nuts,bolts,washer and greese etc as required to rectify the complaint. In this regard Accepting Officer's decision is final (iii) Major spares required for rectifying the complaint shall be measured and paid separately. (iv) Tools for the repairs and safety of the mechanic/Engineer shall be at contractor's risk. (v) The contractor is bound to send the Mechanic/Engineer within 4 hurs during the VIP/VVIP visit to attend the complaints if any without fail otherwise a penalty of Rs 500.00 shall be recovered per hour upto 24 hours and Rs 1000.00 above 24 hours. (vi) If the contractor failed to attend the complaint within 48 hours, a penalty of Rs 100.00 per hour shall be recovered.
S & F in replacement Power start controller suitable for DG set upto 125 KVA capacity with all engine safety system both mannual and auto start, reset functions with suitable oil pressure sensor, high water temperature safety, over speed regulator safety, earth fault safety, low and high AC voltage safety, internal wiring including taking down old unserviceable power start controller complete all as specified.
All as per item No 44 here-in-above but for DG set 150 to 320 KVA capacity complete all as specified.
All as per item No 44 here-in-above but for DG set 400 to 625 KVA capacity complete all as specified.
All as per item No 44 here-in-above but for DG set 810 KVA capacity complete all as specified.
S & F in replacement One meter long battery lead with stranded copper conductor of 200 Amp DC rating maximum upto 2 run x 1 mtr with brass terminals on both end complete all as specified.
S & F in replacement Residential type silencer suitable for 150 to 320 KVA capacity DG Set as per existing type and model complete all as specified.
S & F in replacement Flexible pipe as per existing type and make complete all as specified.
S & F in replacement Water temperature gauge as per existing type and make complete all as specified.
S & F in replacement Oil temperature gauge as per existing type and make complete all as specified.
S & F in replacement Exhaust bellow as per existing type and make complete all as specified.
S & F in replacement Radiator cap as per existing type and make complete all as specified.
S & F in replacement Digital type, three phase LED Voltmeter including taking down old unserviceable voltmeter complete all as specified.
S & F in replacement Digital type, three phase LED Ammeter including taking down old unserviceable Ammeter complete all as specified.
S & F in replacement Digital type, three phase LED Multi function meter including taking down old unserviceable multi function meter complete all as specified.
S & F in replacement Analog type Ammeter, range 0 - 1400 Amp, class 1.5 including taking down old unserviceable Ammeter complete all as specified.
S & F in replacement Analog type Voltmeter, range 0 - 500 Volts, class 1.5 including taking down old unserviceable voltmeter complete all as specified.
S & F in replacement LED indicator lamp ( Red, Yellow, Amber, Green) including taking down old unserviceable indicator lamp complete all as specified.
S & F in replacement LED indicator lamp ( Blue / white ) including taking down old unserviceable indicator lamp complete all as specified.
S & F in replacement Standard push button, flush head, any colour complete all as specified.
S & F in replacement AMF controller, three phase, 50 Hz, AC, auto/manual/test/off mode with necessary display complete all as specified.
S & F in replacement Fan belt as per existing size and type of the DG set, complete all as specified.
S & Fin replacement Flexible pipe inlet as per existing size and type, complete all as specified.
Supply and replacing storage battery with maintenance free (SMF) self charging, heavy duty battery, sealed, factory charged with in-built SMPS battery charger suitable for 160 to 625 KVA rating complete all as specified.Make : HBL (X-CELL) / Cummins / Excide
Supply and replacing storage battery with maintenance free (SMF) self charging, heavy duty battery, sealed, factory charged with in-built SMPS battery charger suitable for upto 150 KVA rating complete all as specified. Make : HBL (X-CELL) / Cummins / Excide
Supply and replacing lead acid storage battery provides the essential electrical power needed th start the generator and its control panels, heavy duty battery, sealed, often with high cranking power, factory charged 12 Volt and Amp rating 180 Ah rating complete all as specified.Make : Excel/ HBL (X-CELL) / Cummins / Excide
Supply and replacing lead acid storage battery provides the essential electrical power needed th start the generator and its control panels, heavy duty battery, sealed, often with high cranking power, factory charged 12 Volt and Amp rating 150 Ah rating complete all as specified.Make : Excel/ HBL (X-CELL) / Cummins / Excide
Supply and replacing lead acid storage battery provides the essential electrical power needed th start the generator and its control panels, heavy duty battery, sealed, often with high cranking power, factory charged 12 Volt and Amp rating 120 Ah rating complete all as specified.Make : Excel/ HBL (X-CELL) / Cummins / Excide
Supply and replacing lead acid storage battery provides the essential electrical power needed th start the generator and its control panels, heavy duty battery, sealed, often with high cranking power, factory charged 12 Volt and Amp rating 100 Ah rating complete all as specified.Make : Excel/ HBL (X-CELL) / Cummins / Excide
S&F inreplacement of Battery charger 12 Volt for DG set of capacity up to 50 KVA complete all as specified.
S&F inreplacement of Battery charger 12/24 Volt for DG set of capacity 62.50 to 200 KVA complete all as specified.
S&F inreplacement of Battery charger 12/24 Volt for DG set of capacity 250 to 435.7 KVA complete all as specified.
S&F inreplacement of Battery charger 12/24 Volt for DG set of capacity 500 to 625 KVA complete all as specified.
S&F inreplacement of Battery charger 12/24 Volt for DG set of capacity 810 KVA complete all as specified and directed.
Supply and fix inreplacement of Fleet cool HD heavy duty coolant concentrate ultimate protection for increase engine life complete all as specified. Make : Fleet guard /Servo
Supply and fix in replacement of Engine oil as approved by Manufacturer (Make- Volvoline/Castrol/Servo all as specified and directed by Engineer-in-Charge.
S & F in replacement AVRs unit of alternator suitable for DG Set upto 82.5 KVA capacity as per existing type and model complete all as specified.
S & F in replacement AVRs unit of alternator suitable for DG Set 100 to 320 KVA capacity as per existing type and model complete all as specified.
S & F in replacement AVRs unit of alternator suitable for DG Set 400 to 625KVA capacity as per existing type and model complete all as specified.
S & F in replacement MCCB, Three Pole, 63 Amp having breaking capacity of 25 kA, 415 volt AC with thermal magnetic release range 50 - 63 Amp with spreader including taking down old unserviceable MCCB complete all as specified.
S & F in replacement MCCB, Three Pole, 100 Amp having breaking capacity of 25 kA, 415 volt AC with thermal magnetic release range 80-100 Amp with spreader including taking down old unserviceable MCCB complete all as specified.
S & F in replacement MCCB, Three Pole, 125 Amp having breaking capacity of 25 kA, 415 volt AC with thermal magnetic release range 100-125 Amp with spreader including taking down old unserviceable MCCB complete all as specified.
S & F in replacement MCCB, Three Pole, 160 Amp having breaking capacity of 25 kA, 415 volt AC with thermal magnetic release range 125-160 Amp with spreader including taking down old unserviceable MCCB complete all as specified.
S & F in replacement MCCB, Three Pole, 200 Amp having breaking capacity of 25 kA, 415 volt AC with thermal magnetic release range 160-200 Amp with spreader including taking down old unserviceable MCCB complete all as specified.
S & F in replacement MCCB, Three Pole, 250 Amp having breaking capacity of 25 kA, 415 volt AC with thermal magnetic release range 200-250 Amp with spreader including taking down old unserviceable MCCB complete all as specified.
S & F in replacement MCCB, Three Pole, 320 Amp having breaking capacity of 25 kA, 415 volt AC with thermal magnetic release range 300-320 Amp with spreader including taking down old unserviceable MCCB complete all as specified.
S & F in replacement MCCB, Three Pole, 400 Amp having breaking capacity of 25 kA, 415 volt AC with thermal magnetic release range 400 Amp with spreader including taking down old unserviceable MCCB complete all as specified.
S & F in replacement MCB SP 6 - 32 Amp, C-curve, 230 volt AC complete all as specified.
S & F in replacement MCB DP 6 - 32 Amp, C-curve, 230 volt AC complete all as specified.
S & F in replacement MCB 4P, 40 Amp, C-curve, 415 volt AC complete all as specified.
S & F in replacement MCB 4P, 63 Amp, C-curve, 415 volt AC complete all as specified.
S & F in replacement MCB TPN, 100 Amp, C-curve, 415 volt AC having breaking capacity 10 kA complete all as specified.
S & F in replacement Power contactor, three pole, 115 Amp MNX type complete all as specified.
S & F in replacement Power contactor, three pole, 150 Amp MNX type complete all as specified.
S & F in replacement Power contactor, three pole, 185 Amp MNX type complete all as specified.
S & Fin replacement Power contactor, three pole, 225 Amp MNX type complete all as specified.
S & Fin replacement Power contactor, three pole, 265 Amps, MNX type complete all as specified.
S & F in replacement Power contactor, three pole, 330 Amps, MNX type complete all as specified.
S & F in replacement Onload Change Over Switch, in sheet steel enclosure, 200 Amp, 415 volt AC complete all as specified.
S & F in replacement Onload Change Over Switch, in sheet steel enclosure, 250 Amp, 415 volt AC complete all as specified.
S & F in replacement Onload Change Over Switch, in sheet steel enclosure, 400 Amp, 415 volt AC complete all as specified.
M & L Overhauling of DG set engine, up to 160 KVA capacity, comprising of the following work services of item No 106.1.
M & L Overhauling of DG set engine, above 160 to 250 KVA capacity, comprising of the following work services of item No 106.1.
Note for item No 107 to 134 . New components required for replacement shall be measured and paid for separately as 'Supply and fixing '. (a) Disconnection of LT cable from cable end box by unscrewing nuts and bolts. (b) Disconnection of Engine from alternater. (c) Strip the complete Engine carefully, taking out the spare parts. (d) Draining out the unservicable engine oil from the engine. (e) Cleaning all sludges / deposits in the oil sump and removal off the site. (f) Carry out necessary lathe work, cylinder head repairing, boring,etc (g) Replacing of unserviceable components by new one as directed. (h) Calibration of FIP (j) Inject calibration (k) Servicing of radiator and water pump (l) Fed Pump Servicing (m)Re- assemblying the engine including replacement of complete gasket kit. (n) Checking for alignment after connecting with alternater. (o) Refixing cable with suitable size nuts, bolts and washers. (p) Testing the DG set "NO LOAD" and "FULL LOAD" (q) Re-assembling of all parts, spray painting to DG set, testing, ensuring the rated RPM of the DG set and output voltage 415 volts etc complete. (r) Removing the silencer mainfold, opening, cleaning the muflers, necessary gas welding work, reassembling and refitting the same to its base. (s) Dismantling the exhaust manifold, cleaning,replacing gasket,unserviceable bellows including necessary welding works.
Supply and fixing in repairs Liner complete all as specified (Set of 6).
Supply and fixing in repairs Liner " O " ring complete all as specified (Set of 8).
Supply and fixing in repairs valve complete all as specified (Set of 8).
Supply and fixing in repairs valve seat complete all as specified (Set of 12).
Supply and fixing in repairs valve guide complete all as specified (Set of 24).
Supply and fixing in repairs Piston rings complete all as specified (Set of 6).
Supply and fixing in repairs CR bearing STD complete all as specified (Set of 6)
Supply and fixing in repairs Head gasket kit complete all as specified.
Supply and fixing in repairs Packing kit complete all as specified.
Supply and fixing in repairs Hose kit complete all as specified.
Supply and fixing in repairs Oil filter complete all as specified.
Supply and fixing in repairs Fuel filter complete all as specified.
Supply and fixing in repairs Bypass filter complete all as specified.
Supply and fixing in repairs Gasket fuel connection complete all as specified (Set of 12).
Supply and fixing in repairs Gasket copper complete all as specified (Set of 12).
Supply and fixing in repairs Inject ferrule complete all as specified (Set of 6).
Supply and fixing in repairs Stainless steel hose clip 2.5" complete all as specified (Set of 12).
Supply and fixing in repairs Injector cup complete all as specified (Set of 3).
Supply and fixing in repairs Plunger complete all as specified (Set of 3).
Supply and fixing in repairs Vent line hose complete all as specified.
Supply and fixing in repairs flexible pipe inlet complete all as specified.
Supply and fixing in repairs TIC drain hose complete all as specified.
Supply and fixing in repairs Turbo supply pipe complete all as specified.
Supply and fixing in repairs Water manifold tube complete all as specified.
Supply and fixing in repairs HCT switch complete all as specified.
Supply and fixing in repairs Rocker bush complete all as specified (Set of 12).
Supply and fixing in repairs piston complete all as specified.
Supply and fill superior quality distilled water complete all as specified.
Supply and fix inreplacement of relay any type or any size suitable for AMF panel/control panel up to capacity of DG set up to 160KVA
Supply and fix inreplace,ment of relay any type or any size suitable for AMF panel/control panel up to capacity of DG set 200 to 450KVA
Supply and fix inreplacement of relay any type or any size suitable for AMF panel/control panel up to capacity of DG set 500KVA to 810KVA
S & F in replacement of CT 1000/5 Amp, insulated, class 1.0 complete all as specified.
S & F in replacement of CT 800/5 Amp, insulated, class 1.0 complete all as specified.
S & F in replacement of CT 500/5 Amp, insulated, class 1.0 complete all as specified.
S & F in replacement of CT 400/5 Amp, insulated, class 1.0 complete all as specified.
S & F in replacement of CT 200/5 Amp, insulated, class 1.0 complete all as specified.
S & F in replacement of CT 100/5 Amp, insulated, class 1.0 complete all as specified.
S & F in repair of DG Sets of rusted canopy of any size with welding, filling of metal including fixing of sheet metal plate and painting of repair area etc complete all as specified and directed by Engineer-in-Charge.
S & F in repair of DG Sets round locks of any make any size complete all as specified and directed by Engineer-in-Charge.
S & F in repair of DG Sets door open /close butterfly fastener of any make any size complete all as specified and directed by Engineer-in-Charge.
S & F in repair of DG Sets door of aquastic enclosure door to match with existing material and colour of any capacity including fixing and painting etc complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of diesel float with sensor suitable for DG sets of capacity up to 625 KVA existing model and type complete all as specified and directed
Supplying and laying inreplacement of outer dia 25mm of CPVC pipes SDR 13.5 & Plain CPVC SDR 11 fittings in trenches/floor complete all as specified and directed.
Supply and fix inreplacement of high pressure,Ball brass valves of 25mm size with high pressure with polythene float and flynut complete, screwed for upvc pipe pipe or brass ferrule and fixed complete all as specified and directed.
Supply and fixing in replacement of Mild steel diesel storage tank of Capacity 500 Ltr including out let of 25mm bore and to connecting to existing pipe, and fixed a fuel discharge indication pipe, the tank fixed in angle iron of suitable load bearing angle iron base stand of 60x60x6mm angle iron the angle iron height from the ground level 90cm and the angle iron fixed in PCC foundation complete all as specified and directed by Engr-in-Charge.
Material and labour inreplacement of internal wiring complete of DG set control panel/Dg set AMF panel with using suitable size of DC/AC wire complete all as specified and as directed
M & L for collection of fuel from Petrol pump Naval base to MES MT store yard. (a) FOL will be collect from petrol pump Naval Base.. (b) Barrel/Jerricane should be provided by the contractor (c) Man power and Vehicle for the conveyance of FOL should be provided by thge contractor (d) Tools and Euipment like Hose, Pump, Funnel for top up/fill up the DG Set Should be provided by the contractor. (e) MES representative/JE shall be accompany to collect the fuel from MES Store Yard or Petrol Pump of Naval Base.
M & L for topping up fuel to DG Sets located at various location of Naval Base Kochi (a) FOL will be collect from MES Store Yard. (b) Barrel/Jerricane should be provided by the contractor (c) Man power and Vehicle for the conveyance of FOL should be provided by thge contractor (d) Tools and Euipment like Hose, Pump, Funnel for top up/fill up the DG Set Should be provided by the contractor. (e) MES representative/JE shall be accompany to collect the fuel from MES Store Yard or Petrol Pump of Naval Base.
Supply and fix in repair display board on DG Sets made of Acrylic sheet of 3mm thick duly fitted/ screwed to the DG sets outer body all as specified. The minimum size of the board shall be 450mm x 350mm. The following using synthenic enamel paint:- (i) DG capacity _________ (ii) SM/MES No _________ (iii) Location ____________ (iv) Engine Make & Sr No _________ (v) Alternator Make & Sr No _______ (vi) Date of installation ___________ (vii) Date of last service/ 'B' Check ________ (viii) Next servicing/ ;B' Check due ________
WELTRONENGINEERINGSERVICES (BID ID -3474540)
AR Traders (BID ID -3474478)
PRIYA ENTERPRISES (BID ID -3471762)
Jack Electrolinks Private Limited (BID ID -3479645)
ELAN ENGINEERS (BID ID -3474683)
AMRITH ENGINEERS (BID ID -3474168)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.62 MB
BOQ_824074.xls
BOQ • 0.62 MB
Tenderdocument.pdf
Tender Documents • 1.20 MB
Download all tender documents and submit your bid