Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹3.7 L
EMD Value
₹9,220
Closing Date
19 Feb 2026, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Thrissur corporation
Executive Engineer Thrissur corporation
MP-LADS-MP- LADS Installing 3 Nos low mast and 1 No. Mini mast in Division 36, Thrissur Corporation.-6 m low mast installed near NSS Karayogam Office Padinjarechira Road
2026_LSGD_835675_4
PW2-17409/18,21.02.26,EE1
Open Tender
Electrical Works
Item Rate
180 days
Superintending Engineer Thrissur corporation
Please refer Tender documents.
11 documents required · 11 mandatory
₹815
₹9,220
12 Feb 2026
12 Feb 2026
21 Feb 2026
12 Feb 2026
19 Feb 2026
12 Feb 2026
12 Feb 2026 - 17 Feb 2026
8 M Mini mast and 6 m low mast
OD377612/2025-2026:Supplying and erecting on existing foundation bolts of 6 metre Hot dipped galvanized Octagonal pole in single section with 70mm top diameter, 130mm bottom diameter, 3mm sheet thickness, base plate dimensions of 200 x 200x 12 mm suitable for 39 m/sec wind speed. Mounding Ring Type Bracket for Light Fittings for 4 Nos luminaries. Supply of foundation bolts 20mm dia, 600mm long manufactured from special steel ( EN8 Grade) 4 nos per set along with nuts, washers, anchor plate and common template (Make RR Ispat, Lysaght, Bajaj, Valmont)
OD377613/2025-2026:Supplying and erecting on existing foundation bolts of 8 meter Hot dipped galvanized Octagonal pole in single section with 70mm top diameter, 130mm bottom diameter, 3mm sheet thickness, base plate dimensions of 200 x 200x 12 mm suitable for 39 m/sec wind speed. Mounding Ring Type Bracket for Light Fittings for 4 Nos luminaries. Supply of foundation bolts 20mm dia, 600mm long manufactured from special steel ( EN8 Grade) 4 nos per set along with nuts, washers, anchor plate and common template (Make RR Ispat, Lysaght, Bajaj, Valmont)
OD377614/2025-2026: Foundation of size column 500x500x1000mm, Casting of shallow RCC foundation for the 8metre and 6 metre poles with M20 grade cement concrete including reinforcement of 13 kg tor steel. Including all materials and labour charge of earth work excavation, providing cutting, bending and placing in position reinforcement of cold twisted bar as required with positioning of foundation bolts and providing 50mm dia PVC pipe of suitable length for cable entry as required etc complete. In all respect as per approved drawing and direction of engineer-in -charge.
90.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.4.8:Supply Conveyance, installation, testing and commissioning of 120W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
90.12.5.14:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3 core 10 sq mm
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
OD377618/2025-2026:Supplying and fixing of meter box weather proof type (make Sintex IP 67) of size 540x320x200 mm with 2 compartment, for providing single phase energy meter, fuse unit, Isolator, RCCB, Analog Timer. Meter box fixing on the pole using suitable clamps with bolts and nuts etc complete.
OD377620/2025-2026:Supply and fitting in the existing Control panel 16A, 4P contactor for the power tool control and giving connections etc complete.
OD377621/2025-2026:Supply and fitting in the existing Control panel 24 hours digital Timer switch supply voltage 230 V 50 Hz for operating automatic on/off function with IP53 grade protection, operating temperature 10 º C - 50º C, contact>16 A for controlling -main contactor-1 Nos and giving connections etc complete.
OD377622/2025-2026:Supply and fitting in the existing light pole bottom box 6A TP connector for the power tool control and giving connections etc complete.
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
OD377634/2025-2026:Supply and providing 4 pole sheet steel enclosure for independent mounting of MCB/RCCB/Isolator etc. as required
OD377636/2025-2026:Supply and Fixing 32 A, 2 Way neutral links mounted on DMC/SMC base
OD377637/2025-2026:Supply and fitting 32A 230V Porcelain rewireable type fuse unit in the existing meter box and giving connections etc. complete.
OD377638/2025-2026:Providing independent Ordinary pipe earthing using 2.50 meters of 40 mm dia GI pipe connected with GI wire and other specials such as common salt ,charcoal bolts and nuts etc. complete required at site.
OD377649/2025-2026:Supply and laying of 8 SWG hot dip galvanized wires for earthing and including termination with GI thimble etc as required.
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
OD377650/2025-2026:Preparing completion and test certificates for KSEB connection
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
SBD.pdf
Other Document • 1.64 MB
BOQ_1406556.xls
BOQ • 0.31 MB
NIT.pdf
Other Document • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .