Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.3 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹10.1 L+₹50,078.90 (5.23%)Rejected-AOC | L2 | Rejected-AOC Other than lowest bidder |
Tender Value
₹8.7 L
EMD Value
₹17,420
Closing Date
10 Sept 2021, 3:00 pmClosed
AGE I R AND D MANALI
AGE I R AND D MANALI PIN 175103
SPECIAL REPAIR BLDG NO T-53 (OR Living Bk) AT PALCHAN UNDER AGE (I) R AND D MANALI
2021_MES_467034_1
AGE(I)/MNL-34/2021-22
Open Tender
Civil Works
Item Rate
240 days
Palchan
Refer NIT and Tender Documents
5 documents required · 5 mandatory
₹500
AGE I R AND D MANALI
₹17,420
18 Oct 2021
11 Aug 2021
11 Sept 2021
11 Aug 2021
10 Sept 2021
27 Aug 2021
11 Aug 2021 - 26 Aug 2021
Amount
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F mild steel in Joist, channel, angle, or tee sections, Hollow or round steel tubes, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated), Fe 410 -W (GdeE- 250) quality-A, complete all as specified and directed.
S & F mild steel Windows Chajja / wind ties for roof covering including screwing bolts, etc complete all as specified and directed.
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
M&L for preparation of new steel surfaces of any description over 10cm in width or girth not otherwise described and applying 2 coats of Synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
Dismantling of wall/ceilng boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness including cover fillets, complete all as specified and directed.
S&F Pre- painted galvatume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M&L 75mm thick PCC type D-2, (1:4:8) using 40mm graded stone aggregate as in subbase of floor
M&L 50mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate as in plinth protection , all as specified and directed by Engr -in-Charge.
M&L machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and incl 20mm thick screed bed or bedding layer of cement mortar 1:6, all as specified and directed by Engr -in- Charge.
M&L for 12 mm thick prelaminated particle board interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws frame work as in wall panelling complete all as specified and as directed by Engr-in-charge
M&L for 12 mm thick prelaminated particle board interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws frame work as in ceiling complete all as specified and as directed by Engr-in-charge
M&L Plain fillets,square,rectangular or triangular in section, clean sawn, secured with nails or brads of size exc 3sq cm and n exc 6 sq cm of second class softwood
M&L for Second class softwood timber framed and fixed, Clean sawn in scantling, all as specified and directed.
S&F in repairs 4.0mm thick sheet glass ordinary quality and glazing with oil putty in square n. exc. 0.5sq.m in each pane including hacking out from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
M&L for Pre-cast cement concrete block 1:3:6 type C1 (using 20mm graded aggregate) masonry with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified and directed.
M&L Rendering 15mm thick on brickwork or concrete surfaces or surface other than fair face of brickwork in CM (1:4) finished even & smooth (without using extra cement)
M&L for preparation of new plastered surface of wall and applying two coats of cement base paint, white or tinted complete all as specified and directed by engr-in-charge.
Taking down Chowkats or frames with shutters (without taking off shutters from the frame) exc. 1.5 Sqm and n. exc 4 Sqm each.
S & F pressed steel door frames with one or more rebates including necessary fixing lungs hinges lock strike plate etc complete all as specified size of frame 125 x 60mm all as specified and directed by Engineer - in - Charge .
S & F Flush shutters, 30mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides as per SSR Part – I all as specified.
S & F Mild Steel butt hinges, medium weight cold rolled 100mm size all as specified and directed by Engineer - in - Charge .
S & F Extruded aluminium alloy handles, fabricated type, 150mm size all as specified and directed by Engr - in - Charge .
S & F Aluminium anodised, barrel tower bolts of extruded section and fixed length of bolt 150mm long, all as specified and directed by Engineer - in – Charge
S & F mild steel sliding door, bolts, plate type, stove enamelled black with bright bolt not less than 12mm bore, length of bolt 250mm all as specified and directed by Engineer - in - Charge .
M&L preparing new wooden surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of primer complete.
M&L preparing old steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of primer complete.
S&F Mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed.
M&L Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, all as specified and directed by engineer-in-charge.
S&F for 25mm dia MS curtain rod with PVC coating (decorative type) fixed with MS hooks incl side brackets (both side) complete all as specified and as directed by Engineer-in-Charge.
Taking down copper/aluminium point wiring(light,fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit(credit for above items should be made as per conitions separately) and making good distrubed surfaces of walls, floors etc.
Material and Labour for concealed Point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable of size 1 Sqmm stranded for earth continuity wire, to be drawn in and including, PVC medium grade surface casing capping not less then 20 mm width with MS sheet metal sunken switch/Terminal box 1.2 mm thick and ebonite switch board cover 3.0 mm thick or PVC moulded switch board and brass screws with cup washers including all necessary wall cutting and making good disturbed surface all as directed and specified MAKE OF CABLE - Standard / PLAZA / HAVELLS & MAKE OF PVC CASING/CAPING - PRICISION/PRESSFIT/MODI .Note : Cutting chases and making good to match with the adjoining surface shall be included in the unit rate.
(a) One light point controlled by one, one way switch 5/6 Amp
(b) One Socket out let 5/6 Amp point on the same board
(c) One Socket outlet 5/6 Amp point on the independent board
All as per same in item No 35 above but for one socket outlet 15/16 Amp on independent board with 2.5 Sq. mm cable and 1.5 Sq.mm. earth wire.
S &F in replacement Switch piano flush type single pole one way 5 amps.
S &F in replacement Socket out let 2 in one, 5/3 pin 5 Amp independent
S &F in replacement Switch socket combination 5 Amps 5 pin flush type
S &F in replacement Switch socket combination 5 in 1, 5 pin 5/15 Amps flush type universal .
S &F in replacement lamp holder PVC/ Polycarbonate type with back plate suitable for batten fittings.
S &F in replacement Ceiling rose, surface bakelite 65x50 mm three terminal
Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches,sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store or schedule of credt to the contractor (To be measured only when found serviceable in all respects complete for reuse)
Supply and fix in replacement LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.all as specified and directed by Engineer-in-Charge. Make Havells Cat No: CRYSTAL 213T8DSTL18WLED865SGLASS other then Eqvt Bajaj/ CG.
Supply and fix in replacement for LED bulb/lamp of 7/9 Watts Cool Daylight make as specified by Engr-in-Charge Make: Havells Cat No:LHLDERUEML8X007
Supply and fix in replacement for MCB DB 12 Way Sheet metal enclosure factory made for DBs single pole and neutral double door 240 volts with 200 Amps rated bus bar fixed on walls, including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces all as specified and directed by the Engineer-in-charge. Make : Havells/lLEGRANDINDOASIAN
Supply and fix in replacement MCB, SPN, 240Volts , 63 Amps all as specified and as directed by the Engineer-in-charge. Make : Havells/Legrand
Supply and fix in replacement MCB, SP 240 Volts , 10-40 Amps all as specified and as directed by the Engineer-in-charge. Make : Havells/Legrand
NATHU RAM AND SONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .