Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.8 LAccepted-AOC 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | ₹16.8 L Quoted ₹17.2 L | L1 | Accepted-AOC L1 AND ACCEPTABLE |
| 2 | L2₹18.4 L+₹1.2 L (6.89%)Rejected-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | ₹18.4 L+₹1.2 L (6.89%) | L2 | Rejected-AOC NOT L1 |
| 3 | L3₹18.6 L+₹1.4 L (8.27%)Rejected-AOC | ₹18.6 L+₹1.4 L (8.27%) | L3 | Rejected-AOC NOT L1 |
| 4 | L4₹19.0 L+₹1.8 L (10.5%)Rejected-AOC 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | ₹19.0 L+₹1.8 L (10.5%) | L4 | Rejected-AOC NOT L1 |
| 5 | L5₹19.4 L+₹2.2 L (12.9%)Rejected-AOC B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | ₹19.4 L+₹2.2 L (12.9%) | L5 | Rejected-AOC NOT L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
13 Oct 2022, 6:00 pmClosed
CWE AHMEDABAD
CWE AHMEDABAD
REPAIR MAINTENANCE OF HT NETWORK, HT UG CABLE, OVERHAULING AND REPAIR TO TRANSFORMER WITH GODS, FEEDER PILLARS AND INSTALLATION EARTHING AT MIL STN DHRANGADHRA
2022_MES_551146_1
87108
Open Tender
Civil Works
Item Rate
180 days
DHRANGADHRA
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (A) GANDHINAGAR
₹40,000
Yes
13 Dec 2022
10 Sept 2022
15 Oct 2022
10 Sept 2022
13 Oct 2022
1 Oct 2022
Amount
Excavation in trenches not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth for foundation of pole, laying of cables etc not exceeding 10 Sqm on plan and not exceeding 1.5 Metre in depth and getting out in Hard/ dense soil. Complete all as specified and as directed.
Returning, filling in including spreading, levelling, watering and well ramming in layer not exceeding 25 cm in any type of soil. Complete all as specified and as directed.
Removing excavated material not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point. Complete all as specified and as directed.
Material and labour for providing dry river sand as in sand cushioning to UG cable including punning gently. Complete all as specified and as directed. Note : Depth after punning shall be measured and paid.
Material and labour for plain cement concrete 1:3:6 type C-1 (using 20 mm graded stone aggregate) in foundation of pole/ stay assembly etc including necessary form work, complete all as specified and as directed.
Laying only reinforced precast concrete cable cover, class EHV, complete all as specified and as directed.
Material and labour for supplying and laying unrainforced precast concrete cable cover, class HVP, type 1 flat size 300 mm x 180 mm x 40 mm complete all as specified and as directed.
Supply, laying, jointing in repairs of HT 11 KV Earthed XLPE insulated, screened, PVC sheathed armoured heavy duty electric cables with aluminium conductor for working voltage upto and including 11000 volts of cross sectional area 185 Sqmm 3 core complete all as specified and as directed. Make:- Havells, gloster, polycab
Supply, laying, jointing in repairs of HT 11 KV Earthed XLPE insulated, screened, PVC sheathed armoured heavy duty electric cables with aluminium conductor for working voltage upto and including 11000 volts of cross sectional area 150 Sqmm 3 core complete all as specified and as directed. Make:- Havells, gloster, polycab
Supply, laying, jointing in repairs of HT 11 KV Earthed XLPE insulated, screened, PVC sheathed armoured heavy duty electric cables with aluminium conductor for working voltage upto and including 11000 volts of cross sectional area 120 Sqmm 3 core complete all as specified and as directed. Make:- Havells, gloster, polycab
Supply, laying, jointing in repairs of HT 11 KV Earthed XLPE insulated, screened, PVC sheathed armoured heavy duty electric cables with aluminium conductor for working voltage upto and including 11000 volts of cross sectional area 95 Sqmm 3 core complete all as specified and as directed. make:- Havells, gloster, polycab
Material and labour in repairs cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm to 120 sqmm. Complete all as specified and as directed. Make M-SEAL, DENSONS, BIRLA-3M
Material and labour in repairs cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm. Complete all as specified and as directed. Make : M-SEAL, DENSONS, BIRLA-3M
Material and labour in repairs cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm. Complete all as specified and as directed. Make : Raychems, DENSONS, CCI
Material and labour in repairs cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm. Complete all as specified and as directed. Make : Raychems, DENSONS, CCI
Material and Labour in repairs cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm. Complete all as specified and as directed. Make : Raychems, DENSONS, CCI
Material and labour in repairs cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm. Complete all as specified and as directed. Make : Raychems, DENSONS, CCI
Material and labour in repairs for cross arms, bracings, supports, clamps,sheet and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including taking down old and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed. Make as per SI.
Taking out the existing XLPE, 11000 volts grade, HT UG electric cable of size 95 sqmm x 3 core with glands complete from the trenches/ fixed on wall (or) passing through pipes/ in floor Complete all as specified and as directed. Note:- Excavation and Earth work shall be measured and paid separately under appropriate items all as per existing make
All as per item No 19 above but 120 Sqmm x 3 Core
All as per item No 19 above but 150 Sqmm x 3 Core
All as per item No 19 above but 185 Sqmm x 3 Core
Re-laying only in trenches/ fixed on wall (or) passing through pipes/ in floors, connecting up testing and commissioning of serviceable XLPE, 11000 volts grade, HT UG electric cable of size 95 Sqmm x 3 Core cable. Complete all as specified and as directed.
All as per item No 23 above but 120 Sqmm x 3 Core
All as per item No 23 above but 150 Sqmm x 3 Core
All as per item No 23 above but 185 Sqmm x 3 Core
Supply and fixing in repair, Galvanised pipe 80 mm bore, light grade, laid below road/ fixed along the poles/ walls with necessary clamping, etc including taking down old complete all as per specified and as directed. Make : Jindal, Prakesh, Tata Steel
Supply and fixing in repair, Galvanised pipe 100 mm bore, light grade, laid below road/ fixed along the poles/ walls with necessary clamping, etc including taking down old complete all as per specified and as directed. Make : Jindal, Prakesh, Tata Steel
Material and labour for preparation of old painted (outer exposed surface) of electric steel tubler poles over all diminsion 8.5/ 9.0 meters long, painting to be starts from 1.8 Metre above ground level including mild steel channel/ angle iron with bolts, nuts of four pole structure and applying one coat of aluminium paint including writing pole Number with black colour of existing size letters complete all as specified and as directed.
Material and labour for preparation of old painted (outer exposed surface) of electric steel tubler poles over all diminsion 8.5/ 9.0 meters long, painting to be starts from 1.8 Metres above ground level including mild steel channel/ angle iron with bolts, nuts of two pole structure and applying one coat of aluminium paint including writing pole Number with black colour of existing size letters complete all as specified and as directed.
Supply and fixing air break switch (GOD) 11 KV triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps and including taking down the old items. Complete all as specified and as directed.
Material and labour for Horizontal Boring by Passing Galvanised Protection Pipe upto 150 mm Bore (dia), under Road/ Foot Path, not exceeding 10.00 Metre in a Single Length, complete all as specified and as directed.
Material and labour for fault finding of HT,11 KV cable by using cable fault dectector machine and other necessary T&P, finding out the spot of cable fault and marking on ground complete for any size and length of cable all as specified and as directed. (Note : Fault dectector and other necessary T&P shall be arranged by the contractor without pay any extra cost by the Dept.)
Material and labour in repairs for Danger Notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with mild steel clamps, bolts and nuts of approved size, for HT, 25 X 20 cm size including taking down. Complete all as specified and as directed.
Supply and fixing in repairs continuity conductor or main earthing strip lead fixed to wall buried in ground or drawn in conduit/ pipe or fixed to poles for loop earthing etc. as required 32 mm x 6 mm galvanised iron including taking down. Complete all as specified and as directed.
Supply and erecting in repairs of cast iron cable path indicators made out of mild steel sheet duly marked with HT cable 11000 volts and with mild steel angle embeded in PCC 1:4:8 Type D2 (using 40 mm graded stone aggregate) with 60 cm below ground level and 30 cm above ground with sheet painted by "silver colour” complete all as specified and as directed including taking down.
Supplying and laying in repairs synthetic Rubber insulated mats 25 mm thick for voltage 11 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2 Metre x 1 Metre. Complete all as specified and as directed.
Opening Top Lid Cover of Transformer 100 KVA to 200 KVA, 11000/ 433 Volts outdoor type, disconnecting all Internal Connections of HT/ LT Side for Cleaning of Core and Winding by means of Washing by Hosing Down with Clean Dry Oil to remove dust/ sludge on Core and Coil, Cleaning of Oil Tank to remove Sludge deposited, Replacement of Rusted Gasket Set, Burnt Spindle, Broken/ Unserviceable HV/ LV Ceramic Bushing, Broken Arc Horn, Surge Arrestor, Replacement of Silica Gel, etc. complete all as specified and as directed. (a) Cost of Transformer Oil for Cleaning by Hosing down shall deem to be included in the QUOTED UNIT RATE. (b) Gasket Set, HT/ LT Side Ceramic Bushing, Spindle for HT/ LT Side and Are Horn Surge Arrester etc. for Replacement shall deem to be including in the quoted rate.
Dehydration/ Filtration of Transformer Oil by means of Centrifugal Filtration Plant to achieve the specified Di-electric Strength not less than 40 KV at 2.5 mm Gap in Existing Position of Transformer of any Capacity and Transformer Oil for Topping Up at various Transformer location complete all as specified and as directed. Note : Transformer Oil to be used for TOP UP shall be Measured and Paid for separately.
Supply & Top up of New Transformer Oil, conforming to IS:335-1983 to achieve a Di-electric strength not less than 40 KV with oil testing kit 4.0 mm thick to Top Up of the Transformer complete all as specified and as directed.
Supply & fixing in repairs/ replacement of breather assembly filled with Silica Gel same as existing size and weight approved and suitable for Transformer upto 200 KVA complete all as specified and as directed
Supply and fixing in repairs/ replacement of silica gel after replacing old unserviceable one. Complete all as specified and as directed
Supply and fixing in repairs/ replacement of Brass Spindle for Terminal on HT Side Threaded complete with Nut, Washers, etc. same as existing size and suitable for Transformer 63 KVA to 200 KVA 11000/ 433 Volts, after replacing old unserviceable. complete all as specified and as directed.
Supply and fixing in repairs/ replacement of Brass Spindle in repairs Terminal on LT Side Threaded complete with Nut, Washers, etc. same as existing size suitable for Transformer 63 KVA to 200 KVA 11000/ 433 Volts, after replacing old unserviceable. Complete all as specified and as directed.
Supply and fixing in repairs/ replacement of Ceramic Bushing and Gasket on LT Side of Transformer same as existing size 63 KVA to 200 KVA 11000/ 433 Volts after replacing old unserviceable. Complete all as specified and as directed.
Supply and fixing in repairs/ replacement of Ceramic Bushing and Gasket on HT Side of Transformer 63 KVA to 200 KVA 11000/ 433 Volts after replacing old unserviceable. Complete all as specified and as directed.
Supply and fixing in repairs/ replacement of Gasket (Cock Sheet) 6.0 mm thick with Conical Rubber Bush Complete as approved and suitable for Transformer 63 KVA to 200 KVA 11000/ 433 Volts including taking down/ out unserviceable Gasket, complete all as specified and as directed.
Material and labour in repairs, earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6 mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 Metre below normal ground level, connected to galvanized earth strip of 32 mm x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part I connected to earth test point using as earth lead all as specified and testing on completion including provision of earth lead protected by 40 mm dia light grade Galvanised pipe & watering pipe shall be 20 mm bore medium grade galvanised pipe including all excavation and earth work in any type of soil, PCC pit with RCC cover, char coal, salt, funnel etc complete. Note : Rate quoted by tenderers shall be deemed to include for following provisions;- [i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 Metre. [ii]. PCC 1:3:6 type C1 using 20 mm graded stone aggregate in pit & 40 mm thick precast RCC 1:2:4 type B1 (using 20 mm graded stone aggregate) cover 50 cm x 50 cm with 8 mm TMT bars @ 10 cm C/C both ways with handles. [iii]. Main earthing lead from earth electrode to test point upto 7.5 Metre. [iv]. Funnel with watering pipe [Galvanised pipe] 20 mm bore [ISI marked] medium grade & copper lugs, charcoal & salt as reqd. [v]. Galvanised protection pipe of size 40 mm bore light grade 7.5 Metre.
Material and labour for opening HT, 11 KV, 400 Amp, VCB front and back side complete after taking shut down HT breaker, Timing test, CRM test, insulation resistance test, relay test by secondary injection, check motor charge mechanism, potential transformer resistance measurment, checking control power cable connection , cleaning the dusting inside & out side of VCB greasing oiling the mechanical parts and relay setting of VCB and Complete servicing and testing over load relay, digital voltmeter, digital ammeter, indication lamp and all the protective equipment inside the VCB to be serviced and working properly with necessary replacement of defective equipments complete all as specified and as directed. NOTE : Replacement of the following items of (a) to (k) shall be measured and paid for separately:-
(a) Replacement of indicating lamps all as existing make and size
(b) Replacement of internal wiring for indicating lamps
(c) Replacement of wiring for tripping coil (No volt coil), tripping switch set
(d) Replacement of No Volt coil of suitable capacity
(e) Replacement of power pack dual input/ 110 volt DC as per existing size and make
(f) Replacement of synthetic rubber boot
(g) Replacement of calix spring charge input handle
(h) Replacement of CGI-14 C Relay OR 14N
(I) Replacement of rack in rack out gear
(j) Replacement of 11 KV PT FUSES
(k) Replacement of spring charging motor
Material and labour for opening off HT RMU compact outdoor type which consists of, cleaning the dusting inside & out side, and decarbonising the contact and applying greasing/ oiling for the mechanical parts and including the replacement of the defective items as following :- (a) Replacement of indicating lamps - 03 Numbers. (b) Replacement of internal wiring for indicating lamps - 03 Numbers. (c) Replacement of wiring for tripping coil (No Volt coil), tripping switch set. (d) Replacement of No Volt coil of suitable capacity - 01 Number. (e) Complete servicing and testing of RMU,check control cable connection,check power cable connection, checking gas pressure in RMU, checking earth fault relay, Over load relay, digital voltmeter, digital ammeter, indication lamp, over load triping setting and all the protective equipment inside the RMU to be serviced and working properly with necessary replacement of defective equipments complete all as specified and as directed. (f) Cleaning systhetic rubber boot if damaged change the boot.
Material and labour for dismantling/ taking out incoming & outgoing HT 11 KV cable from RMU 11 KV 630A and taking out RMU from the platform/ foundation with the help of chain pulley and hydra arrangement and taking out to the work shop/ factory to refilling SF6 Gas and repairs/ replacement of falted item for smooth functioning of RMU and control system and the same to be refixing on the platform/ foundation after repairs/ replacement of SF6 Gas and connecting item and refixing including labour and transportation charges complete all as specified and as directed. Note:-1. Bus bar panel shall be fixed in lieu of unserviceable RMU the HT Bus bar panel to be measured and paid seperataly under this schedule. 2. Transpotation charges shall deem to be included in the QUOTED UNIT RATE.
Supply and fixing in repairs/ replacement of Lightning Arresters Non-Linear Type, complete with all Fittings including Galvanised wire 6 mm dia with pvc pipe upto earth test point, nut bolts and Transmission Class, Discharge Capacity 65 Kilo Amp suitable for 11000 Volt, complete all as specified and as directed.
Supply and spread 40 mm to 80 mm graded stone aggreate under the sub station installation area complete all as specified and as directed
Supply, installation, commissoning and testing in repairs/ replacement of, Bus bar panel HT 11 KV with HT bus bar 3-phase, including thimble and gland and connecting material plinth mounted, factory made, outdoor type, weather and vermin proof (Protection Class IP-54) made out of 60 mm x 60 mm x 6 mm angle iron frame and 3.15 mm thick mild steel Sheet CRCA sheet powder coated with front & back hinged opening, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint (First Quality) over a coat of red oxide primer, grouting panel through angle iron, 0.2 Metre in ground and 0.3 Metre over the ground including excavation & earth work in any type of soil and PCC complete comprising of the followings:- (a) Aluminium HT 11 KV bus bar chamber having suitable nuts and bolts for connecting HT cable for 02 Numbers cables (incoming and outgoing cables) complete all as specified and as directed
Material and labour in repairs for HT bus bar box suitable to connect 11 KV (03 Nos) cables during the repairs to HT RMU, structure for continous supply during repair work, the bus bar box made out of 3.15 mm thick CRCA sheet out door type, front and rear openable having aluminium bus bar of 400 Amps rated capacity mounted on insulators and duly powder coated complete all as specified and as directed. Note: The bus bar box shall be used for various locations at mil stn dhrangadhra and shall be measured as one item only
ALBA AC AND REF SERVICES
SATISH ELECTRICALS
Electricals India
Abhishek Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .