| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹36.0 LAccepted-AOC | 1 | Accepted-AOC Being L-1 | |
| 2 | 2₹36.8 L+₹80,125.30 (2.23%)Rejected-Finance DOOR NO 65 4 426 2 SANTHIGIRI COLONY GAJUWAKA POST GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530026 | 2 | Rejected-Finance Not L-1 | |
| 3 | 3₹37.5 L+₹1.5 L (4.25%)Rejected-Finance | 3 | Rejected-Finance Not L-1 | |
| 4 | 4₹38.8 L+₹2.9 L (8.01%)Rejected-Finance | 4 | Rejected-Finance Not L-1 | |
| 5 | 5₹39.8 L+₹3.9 L (10.8%)Rejected-Finance | 5 | Rejected-Finance Not L-1 |
Tender Value
Refer Docs
EMD Value
₹88,000
Closing Date
18 Mar 2021, 6:00 pmClosed
Lt Col Vijay Singh GE
Garrison Engineer Naval Depot Industrial Estate Post 104 Area Visakhapatnam 530007
PROVN OF HARD STANDING FOR VISITORS PARKING AT MEGHADRIPETA COLONY PROVN OF STORAGE ACCN TRAINING SHED AND MT YARD GATE AT MOV NEW SITE UNDER AGE BR I OF GEND VISAKHAPATNAM
2021_MES_423511_1
8942
Open Tender
Civil Works
Item Rate
180 days
Visakhapatnam
As per NIT
7 documents required · 7 mandatory
₹500
Yes
GE ND Visakhapatnam
₹88,000
Yes
19 Jun 2021
18 Feb 2021
23 Mar 2021
18 Feb 2021
18 Mar 2021
5 Mar 2021
Amount
M & L for Machine pressed precast cement conctete coloured interlocking paver block with grey cement and pigment, any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade over and including 50mm thick sand filling over 75mm thick PCC 1:4:8, type D-2 (using 40mm graded stone aggregate) sub base including surface dressing not exc 15cm deep in soft / loose soil complete all as specified and directed.
M & L for moorum / red bajri filling under floors or in foundations in layers not exc 15cm thick, spread, levelled and rammed including watering to required level complete all as specified and directed.
M & L for brick work with fly ash bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 using old size bricks complete all as specified and directed.
M & L for PCC 1:2:4, type B-1, using 20mm graded stone aggregate as in cast in lintels upto 1.5m span, copings, bed blocks for hold fasts, bed plates, roof kerbs and similar work including weathering, slightly rounded or chamfered angles and throating, as directed including necessary form work complete all as specified and directed.
M & L for Precast RCC 1:2:4, type B-1 using 20mm graded stone aggregate as in landings, cover slabs (for manholes), shelves including necessary formwork, and the like and set in CM 1:4 complete all as specified and directed.
M & L for TMT bars 10mm dia and over, as in reinforcement cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including Mild Steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
S & F mild steel framed work as in grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars, barred iron doors; ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290 Gde-E-165complete all as directed
M & L for preparation of new or previously untreated steel surfaces of any description, not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
M & L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth with out using extra cement complete all as specified and directed.
M & L for preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directetd.
M & L for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed by Engineer-in-Charge
Cutting holes into or through cement concrete slabs, chajjas, etc. reinforced or otherwise for embedding balusters of supporting railas as required superficial area over 100 Sqcm but not exc 250 Sqcm complete all as directed.
Excavation in trenches not exc 1.5m wide and depth for foundations, laying of cables, pipe etc n.exc 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm thickness as in soil complete all as specified and directed.
M & L for providing and injecting chemical emulsion for anti-termite treatment at bottom and sides of excavation using chemical emulsion Chloropyrifos 20 EC at 1% concentration at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed by Engineer-in-Charge.
M & L for providing and injecting chemical emulsion for anti-termite treatment to the top surface of filled earth using chemical emulsion Chloropyrifos 20 EC at 1% concentration at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed by Engineer-in-Charge.
M & L for Hardcore of gauge not exc. 63mm, deposited, spread and levelled in layers not exc 15cm thick, watered and rammed to a true surface using broken stone or boulders complete all as directed.
M & L for PCC 1:4:8, type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as directed.
M & L for 75mm thick, PCC 1:3:6, type C-2, using 40mm graded stone aggregate as in plinth protection / floors laid to slope in panels including finishing the surfaces even and fair complete all as specified and directed.
M & L for RCC 1:11/2:3, Type A-1 (using 20mm graded stone aggregate) as in beams, cantilevers, lintels over 1.5m span complete all as specified and directed.
M & L for RCC 1:11/2:3, Type A-1 (using 20mm graded stone aggregate) as in chajjas and the like complete all as specified and directed.
Use and waste of formwork to sides and soffits of floor or roof beams, lintels and similar work for rough finished surfaces of concrete flat complete all as specified and directed.
Use and waste of formwork to sides and soffits of chajjas and similar work for rough finished surfaces of concrete flat complete all as specified and directed.
M & L for TMT bars 6 to 8mm dia and over, as in reinforcement cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including Mild Steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
M & L for TMT bars 5mm dia and over upto 10mm dia as in reinforcement cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including Mild Steel wire (annealed) not less than 0.9mm dia as in stirrups, spacers, binders complete all as specified and as directed.
S & F rolled mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS:1161-1979 grade St-240 including one shop coat of zinc chrome primer complete all as directed
M & L for rolled mild steel work in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc including one shop coat of zinc chrome primer complete all as specified and directed by Engineer-in-Charge.
M & L for rolled mild steel plates (plain or chequered) channels, square cut or notched forming holes with riveted, bolted or welded attachment conforming to Fe 290 Gde E-165 complete all as directed
S & F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exc 30cm long and diameter of neck 12 to 20mm complete all as specified.
M & L for brick work with fly ash bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 using old size bricks complete all as specified and directed.
M & L for 75mm thick, PCC 1:2:4, type B-2, using 40mm graded stone aggregate as in plinth protection / floors including finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 5mm thick in CM 1:3 on fair faces of concrete surfaces / ceiling surfaces finished even and smooth with out using extra cement complete all as directed.
M & L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces mixed with and including cement water proofing @ 2% by weight of cement finished even and smooth with out using extra cement complete all as specified and directed.
M & L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth with out using extra cement complete all as specified and directed.
M & L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and directetd.
M & L for preparation of newly plastered surfaces of wall and applying two coats of washable distemper oil emulsion over a coat of primer complete all as specified and directed.
M & L for preparation of newly plastered surfaces of ceioling and applying three coats of white wash complete all as specified and directetd.
M & L for 40mm thick, PCC 1:2:4, type B-1, using 20mm graded stone aggregate as in flooring finished the surfaces even and smooth complete all as specified and directed.
Cutting holes in brick walls built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as directed by the Engineer-in-Charge
M & L for providing and injecting chemical emulsion for post construction anti-termite treatment at points of contact of wood work by chemical emulsion CHLOROPYRIFOS 20 EC at 1% concentration at the rate of 0.5 litre per each hole by drilling 6mm dia holes at a downward angle of 45 Degree at 150mm centre to centre complete all as specified and directed by Engineer-in-Charge.
M & L for 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints including treating backs of chowkats with tar or coal tar black paint complete all as specified and directed.
S & F mild steel work as in hold fasts for fixing chowkats and similar small articles including treating the hold fats with tar or coal tar black paint complete all as specified and directed.
M & L for 40mm thick factory made flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
M & L for 2nd class hard wood 35mm thick factory made Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc. complete all as specified and directed.
S & F Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 of size 100mm complete all as specified and directed.
S & F aluminium anodised barrel tower bolt of size 200mm long of extruded section complete all as directed.
S & F 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as directed.
S & F extruded aluminium alloy handles fabricated type anodised of size 150mm complete all as directed.
S & F aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm fixed with aluminium wire staples complete all as specified and directed.
M & L for Aluminium powder coated (Thickness of powder coating 50 micron) Deco grills of Model DG-104 (10mm) with aperture of size 105x99mm riveted with rivets and fixed with and including suitable aluminium 'F' or 'E' channels with necessary fixing arrangements complete all as directed.
M & L for preparation of new or previously untreated wooden surfaces of any description, not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as directed.
M & L for Anodised aluminium snap grid false ceiling of grid size 605 x 605mm consisting of aluminium wall angles of size 38mmx25mmx2.4mm thick weighing 0.36 Kg/Rm, main & Cross tees of size 36.5mmx25mmx1.4mm thick weighing 0.24 Kg/Rm including cutting, drilling, jointing, suspended with and including 4mm dia galvanised mild steel wire fixed with adjustable connectors at intervals not more than 60mm c/c fixed to roof slab by means of ceiling cleats made of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long including 12mm thick gypsum board fixed with corrosion resistant self taping zinc plated dry wall screws with counter sunk cross heads on snap grid including applying 3mm thick wall care putty for making good undulations to obtain smooth surface and applying two coats of plastic emulsion paint over a coat of primer on exposed surfaces complete all as specified and directed.
S & F Pre-painted galvalume aluminium zinc coating GI based corrugated / 'Z' profile steel sheet of 0.50mm thick, any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick, any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M & L for coloured joint free Non skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
All as per item No. 56 above but in vertical surfaces such as dado / skirting, etc over and including 10mm thick backing coat in CM 1:3
Removing excavated material /soil to a distance not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed
M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 1.5 Sqmm (nominal area) 1100V grade drawn through and including concealed PVC conduit of size not less than 20mm dia medium grade including accessories fixed on wall/floor/roof, etc including provision of modular terminal box with plate, provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for One light / fan point / Bell / 5 Amps socket point controlled by one, one way switch complete all as specified and directed. [Note: Quoted rate is deemed to be inclusive for cutting, chasing, pinning in and making good disturbed surfaces as required to the satisfaction of Engineer-in-Charge]
All as per item No. 59 above but point wiring with 4.0 Sqmm (nominal area) suitable for one power point on independent board complete all as specified and directed.
S & F modular switch, 1 way, 6 Amps, 1 module
S & F ceiling rose, 3 terminals, PVC/ polycarbonate, isolated body complete all as specified and directed
S & F modular switch, 1 way, 16 Amps, 1 module
S & F modular socket outlet, 6 Amps, 2/3 pin combined 2 module
S & F modular socket outlet, 6/16 Amps, 2/3 pin combined 2 module
S & F modular electronic fan regulator, socket type, omplete all as specified and directed.
S & F LED tube light fittings, retro bar professional WH 5700K to 6200K and minimum 1800 to 2000 lumens of cool white comprising of batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
S & F Building Security light LED type of minimum 3000 Lumens Pressure die cast aluminium housing IP 66 protection with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including bracket made of 25mm dia GI light grade pipe of 1.2m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted complete all as specified and as directed by the Engineer-in-Charge.
S & F ceiling fan, Five star rated, single phase, 230Volts of size 1200mm sweep including regulator and provision of twin core flexible copper cable of suitable size from ceiling rose to fan complete all as specified and directed by the Engineer-in-Charge.
S & F MCB, SP, 56 to 32 Amps, 240 Volts
S & F MCB, TPN, 63 Amps, 415 Volts
S & F MCB DB, TPN, 4 way, double door (fixed flush to the wall), 415 Volts with 200 Amps rated bus bar, IP-42 protection with suitable size copper conductor (PVC sheathed copper cable) for earth continuity including making good disturbed surfaces complete all as specified and directed.
Supply and Laying LT XLPE insulated, PVC sheathed, bedded, galvanised steel strip or wire armoured, heavy duty, electric power cables of size 4 core 16 Sqmm, 1100 volts grade, with aluminium conductor laid in trenches / passing through pipe / duct / fixed on walls complete all as specified and directed.
Supply and laying GI tubing 40mm dia, light grade as in cable protection complete all as specified and directed by the Engineer-in-Charge
M&L for Sand filling in trenches using dry river sand as cushioning to under ground cable including spreading, levelling and consolidation complete all as specified and directed. [Note: Punned thickness of sand shall only be measured.]
M & L for laying sub class 'B' bricks of old size 230mm x 115mm x 75mm for cable protection laid across alignment of cable in trenches complete all as specified and directed.
Earthing complete with Galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground with earth pit not less than 2.25m deep below the normal ground level with top edge of plate not less than 1.5m below normal GL connected to GI earth lead 4mm dia by means of bolts, nuts, check nuts and washers of Galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on ompletion and dismantling old earthing set complete all as directed. [Note: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, MS angle iron frame 40x40x6mm, cast iron cover, MS handle 12mm dia, CI funnel and wire mesh, GI watering pipe 20mm dia medium grade for watering, GI protection pipe light grade 15mm dia, earthing lead upto 7.5m complete all as specified in preambles of SSR Part-II and as shown in plate No. 3 of SSR Part-I.]
S & F Earth continuity conductor or main earthing lead of 4mm dia GI wire fixed to wall on batten or recess or cases or buried in ground or drawn in conduit / pipe or fixed to poles complete all as specified.
M & L for cutting of road / hard standing for laying of cables and making good the disturbed portion in PCC 1:3:6, type C-1 using 20mm graded stone aggregate including removal of debris to a distance not exc 50m complete all as specified and directed.
K K INFRA
HEVENNY ENGINEERING CONSTRUCTIONS
ESWAR ENTERPRISES
TECHNO SOFT SOLUTIONS
ALLURI CONSTRUCTIONS
Balaji Enterprises
N V S S K N SIVA PRASAD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .