Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 LAdmitted-Finance | ₹2.2 L | L1 | Admitted-Finance |
| 2 | L2₹2.3 LAdmitted-Finance | ₹2.3 L | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical as per e nit |
| Sl No | Description | Qty | Unit | M/S ISHAN ELECTRICAL and MECH. ENGG. WORKS L1 | VEE AUTO TRADERS L2 |
|---|---|---|---|---|---|
| 1.00 | Repairs to AMF Panel of Diesel Generating Set by disconnecting the incomings and outgoing electrical power supply to the panel and extract the damaged Air Circuit breaker from the panel by removing the bolts & Nuts of the same and disconnecting the incoming and outgoing cables of the Breaker then bringing the breaker outside from the panel and repairs to 02 No. Air Circuit Breakers and fitting back the cover of the Breaker after complete servicing and putting back the complete breaker in the panel by fitting bolts and nuts and tightening the same and connecting the cables both incoming and outgoing then complete trail taken the breakers of the panel at full load by repeating the trial process 2 or 3 times. The job also includes repair/replacement of Programmable Logic Controller, Relays, internal wiring and other allied items. Complete job comprises of cost of material and labour charges, transportation, reinstalling, tools and tackles and other unforeseen material for execution of job and taxes thereof. | 1 | JOBS | 0.01 ₹69,300 | 0.01 ₹75,834 |
| 2.00 | Shifting of 400 KVA Automatic Voltage Controlled Servo Stabilizer-01 No. from Govt. Chest Diseases Hospital, Jammu to Workshop for its Repair by way of Draining out Transformer Oil and storing it properly in barrels. Dragging out the Stabilizer from Govt. Chest Diseases Hospital, Jammu by deploying skilled labour and with the help of Hydra crane, tools & tackles. Shifting of Stabilizer to workshop by Mechanical Transport, dismantling it by unfastening nut bolts of top cover there by extracting out damaged synchronizing motors, cards & wiring. Job also includes providing & fitting of new control card-03 No’s, synchronous motor-01 No’s, Limit switches moving arms-03no’s, replacement of new insulation, phase indicators set with changing of panel wiring and internal wiring etc. The job also includes Placing of all dimmer assemblies in electric oven for drying and removing of moisture for required time and appropriate temperature. The job also includes Lubrication of all the gear of servo motor, servicing of oil chamber by checking for leakage and plugging if any by way of welding and applying adhesive to make it to leak proof. Assembling of stabilizer and topping up with reprocessing/de-hydrated old servo-oil so that all coils were fully immersed in the oil. Further, the job involves refitting/reassembling of 400 KVA Automatic Voltage Controlled Servo Stabilizer, shifting of the same to installation position and connecting it to main power supply & testing on full load dedicated for existing HVAC System. Complete job comprises of cost of material and labour charges, transportation, reinstalling, tools and tackles and other unforeseen material for execution of job and taxes thereof. | 1 | JOBS | 0 ₹33,000 | 0.01 ₹36,135 |
| 3.00 | Providing and laying of PVC insulated and PVC sheathed/XLPE aluminum conductor power cable of 1.1 KV grade armoured cable of 1 core x 400sq mm, 1100 volts from Main to Servo and interconnections as per site requirements conforming to relevant IS Codes with latest amendments up to date of Gloster/ Havells/ CCI/ National/ Sky tone/ SRP/ Ellcotech/ KEI/ Polycab/Grandlay. The cables are to be duly carried along through existing cable trays including horizontal and vertical bends, cross members and other accessories as required including fasteners, supports, welding etc., as required. The cable ends are to be fixed with suitable heavy duty aluminum lugs duly crimped with crimping tool, PVC tape, etc. as required for each length of the cable. Complete job as per site requirements & as per instructions of Engineer-in-charge and includes cost of labour, transportation, and all kind of taxes (GST) thereof. | 108 | MTRS | 0 ₹1.1 L | 0.01 ₹1.2 L |
Tender Value
₹2.3 L
EMD Value
₹5,000
Closing Date
2 Mar 2026, 4:00 pmClosed
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
Repairs to AMF Panel of DG Set of 500 KVA with Shifting of One No. 400 KVA Automatic Voltage Controlled Servo Stabilizer from Govt. Chest Diseases Hospital, Jammu to Workshop for its Repair and further to be shifted from workshop to Govt. Bone Join
2026_PWDJK_304142_1
MHDJ/e-NIT 374 of 2025-26
Open Tender
Repair and Maintenance Services
10 days
bone and joint hospital jammu
as per e nit
2 documents required · 2 mandatory
₹200
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
₹5,000
25 May 2026
21 Feb 2026
3 Mar 2026
21 Feb 2026
2 Mar 2026
24 Feb 2026
21 Feb 2026 - 2 Mar 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: Executive Engineer, Mechanical & Hospital Division GMCH Jammu.
Repairs to AMF Panel of DG Set of 500 KVA with Shifting of One No. 400 KVA Automatic Voltage Controlled Servo Stabilizer from Govt. Chest Diseases Hospital, Jammu to Workshop for its Repair and further to be shifted from workshop to Govt. Bone & Joint Hospital, Jammu and connections of the same with Main Electric Panel and allied works for the smooth functioning of the existing HVAC System at Govt. Bone & Joint Hospital, Jammu
MHDJ/e-NIT 374 of 2025-26 Dated: 21.02.2026 Due : 02.03.2026
Sl. No. Item Code / Make Quantity Units Estimated Rate Addition / Deduction Rate including GST to be quoted by the bidder Rs. P Currency Convertion against each Item Quoted Currency in INR / Other Currency Rebate on old parts in Percentage (%) if any Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category Net Cost of item Rs. P
1 Repairs to AMF Panel of Diesel Generating Set by disconnecting the incomings and outgoing electrical power supply to the panel and extract the damaged Air Circuit breaker from the panel by removing the bolts & Nuts of the same and disconnecting the incoming and outgoing cables of the Breaker then bringing the breaker outside from the panel and repairs to 02 No. Air Circuit Breakers and fitting back the cover of the Breaker after complete servicing and putting back the complete breaker in the panel by fitting bolts and nuts and tightening the same and connecting the cables both incoming and outgoing then complete trail taken the breakers of the panel at full load by repeating the trial process 2 or 3 times. The job also includes repair/replacement of Programmable Logic Controller, Relays, internal wiring and other allied items. Complete job comprises of cost of material and labour charges, transportation, reinstalling, tools and tackles and other unforeseen material for execution of job and taxes thereof. JOBS Excess(+) Full Conversion INR
2 Shifting of 400 KVA Automatic Voltage Controlled Servo Stabilizer-01 No. from Govt. Chest Diseases Hospital, Jammu to Workshop for its Repair by way of Draining out Transformer Oil and storing it properly in barrels. Dragging out the Stabilizer from Govt. Chest Diseases Hospital, Jammu by deploying skilled labour and with the help of Hydra crane, tools & tackles. Shifting of Stabilizer to workshop by Mechanical Transport, dismantling it by unfastening nut bolts of top cover there by extracting out damaged synchronizing motors, cards & wiring. Job also includes providing & fitting of new control card-03 No’s, synchronous motor-01 No’s, Limit switches moving arms-03no’s, replacement of new insulation, phase indicators set with changing of panel wiring and internal wiring etc. The job also includes Placing of all dimmer assemblies in electric oven for drying and removing of moisture for required time and appropriate temperature. The job also includes Lubrication of all the gear of servo motor, servicing of oil chamber by checking for leakage and plugging if any by way of welding and applying adhesive to make it to leak proof. Assembling of stabilizer and topping up with reprocessing/de-hydrated old servo-oil so that all coils were fully immersed in the oil. Further, the job involves refitting/reassembling of 400 KVA Automatic Voltage Controlled Servo Stabilizer, shifting of the same to installation position and connecting it to main power supply & testing on full load dedicated for existing HVAC System. Complete job comprises of cost of material and labour charges, transportation, reinstalling, tools and tackles and other unforeseen material for execution of job and taxes thereof. JOBS Excess(+) Full Conversion INR
3 Providing and laying of PVC insulated and PVC sheathed/XLPE aluminum conductor power cable of 1.1 KV grade armoured cable of 1 core x 400sq mm, 1100 volts from Main to Servo and interconnections as per site requirements conforming to relevant IS Codes with latest amendments up to date of Gloster/ Havells/ CCI/ National/ Sky tone/ SRP/ Ellcotech/ KEI/ Polycab/Grandlay. The cables are to be duly carried along through existing cable trays including horizontal and vertical bends, cross members and other accessories as required including fasteners, supports, welding etc., as required. The cable ends are to be fixed with suitable heavy duty aluminum lugs duly crimped with crimping tool, PVC tape, etc. as required for each length of the cable. Complete job as per site requirements & as per instructions of Engineer-in-charge and includes cost of labour, transportation, and all kind of taxes (GST) thereof. MTRS Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information