Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance P5 ELECTRICAL AND ELECTRONIC INDUSTRIAL ESTATE NIT THUVAKUDI TIRUCHIRAPPALLI TAMIL NADU 620015 | TIRUCHIRAPPALLI | TAMIL NADU | 620015 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 21 22 RARA MANZILA JASDANWALA OFFICE COMPLEX GROUND FLOOR PHASE 1 M G ROAD PANVEL | PANVEL | RAIGAD | MAHARASHTRA | 410206 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance 7 91 KOTTARAPATTI PATHALAPETTAI POST TIRUCHIRAPPALLI TAMIL NADU 620013 | TIRUCHIRAPPALLI | TAMIL NADU | 620013 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹9,957
Closing Date
8 Oct 2020, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Director, NITT
The Director, National Institute of Technology, Tiruchirappalli-620 015.
Providing UPS power supply to faculties room PCs at CSE dept. Ground floor, first floor and second floor IT Centre building.
2020_NITT_583815_1
NITT/EMD/EE/AE(E)/Tender Notice/Enq.No. 08/20-21
Open Tender
Electrical Works
Works
60 days
National Institute of Technology Tiruchirappalli
As per Tender Document.
9 documents required · 9 mandatory
₹0
₹9,957
Yes
24 Nov 2020
15 Sept 2020
9 Oct 2020
15 Sept 2020
8 Oct 2020
21 Sept 2020
15 Sept 2020 - 8 Oct 2020
30 days
Amount
WIRING
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
4 Module (125mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
DLP plasticTrunking wiring (Make: Legrand/MK)
DLP Pastic Trunking 105x50mm and accessories Flexible cover 85mm -1No, Joints for cover 85mm width-1No,Basejoint-25Nos,Clips-15Nos,Separation partition-1No,Endcap-2No,Internal angles-adjustable from 80 degr - 120 deg - 1No, VDI accessories for internal angles-1No,VDI accessories for external angles -1No, Flat angles -1No, VDI accessories for flat angles-1No, Flat junctions-1No, Flat junctions for specific size-tap off to an 80mm wide branch -1No, VDI accessories for juctions -1No, Wall crossing -1No, Capacity change -1No,Capacity change-1No, partition junction -1No, Cable ties base -1No. (Make: Legrand/MK)
DLP Pastic mini Trunking system 32x12.5mm and accessories Endcap-1No,Internal angles-adjustable from 85 degr - 95 deg - 1No,Flat junctions -1No.(Make: Legrand)
DLP Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed as required.(Make: Finolex/Polycab/RR)
2 X 4.0 sq. mm + 1 X 4.0 sq. mm earth wire
2 X 6.0 sq. mm + 1 X 6.0 sq. mm earth wire
4 X 6.0 sq. mm + 2 X 6.0 sq. mm earth wire
MCCB, MCB & DB'S
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way , Double door
Supplying and fixing of following rating,double pole/single pole,240 volts,Isolator/MCB in the existing MCB/DB complete with connections,testing and commissioning etc.as required.
Double pole 40-63A MCB
MV CABLE LAYING
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
MV CABLE JOINTING & END TERMINATION
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3Y X 240 sq. mm (62mm)
MISC. CIVIL ITEMS
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
120 mm dia (OD-120 mm & ID-103 mm nominal)
SUPPLY OF ELECTRICAL ITEMS
Repairing and painting works.
Labour charges for removing of Conceled switch box with necessary arrangements etc. as require.
Labour charges for fixing 2-4 Pole sheet steel enclosure on surface/ recess with necessary connections, testing and commissioning etc. as required
Labour Charges for fixing of 1P to 4P MCB in exisiting MCB DB with necessary connections etc. as required.
Supplying of Cables.
Supplying of following size ISI marked PVC insulated and PVC sheathed aluminium grade with armoured as required.(Make:Finolex,Gloster,Polycab and Havells with 18 months warranty from the date of supply)
3½ X 240 Sq mm
MANOJ ENTERPRISES
V.ARUNACHALAM ELECTRICAL CONTRACTOR
POWER ELECTRICAL WORKS
Essen Instrumentation and Electricals
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .