Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹51.7 L
Closing Date
13 Jul 2026, 3:00 pmClosed
U N Mehta Institute of Cardiology & Research Centre
E-tender for Rate Contract for Supply of Lifesaving Permanent Implant Product (Item), for Lifesaving Cardiac Operations and Cardiac Procedures (Adult, Paediatric & Neonatal) i.e. Coronary Stent for U N Mehta Institute of Cardiology and Research Centre (Affiliated to B. J. Medical College & NABH Accredited) Ahmedabad, Gujarat, India.
313359
14 of 2026
Open
Health & Medicines
Supply
Ahmedabad
2 documents required · 2 mandatory
₹17,700
U. N. Mehta Institute of Cardiology and Research Centre
₹51.7 L
11 Jun 2026
11 Jun 2026
13 Jul 2026
11 Jun 2026
2 Jul 2026
11 Jun 2026
Technical Compliance Sheet of E - Tender for Rate Contract for Supply of Coronary Stent, E - Tender ID # 313359
SN Product (Item) Name Product (Item) Description Required Size Mandatory Product (item) Certification Required for Product (item) Qualification Unit Brand Name Manufacturing Company Reference No. Quoted Size Compliance to the Tender Specification (Yes/No) Deviation, If any
1 Bare Metal Stent - Cobalt Chromium - All Sizes USFDA approved 1
2 Bare Metal Stent - Cobalt Chromium - All Sizes CE approved 1
3 Bare Metal Stent - Cobalt Chromium - All Sizes DCGI approved 1
4 Sirolimus Coated Drug Eluting Stent with Durable polymer - Cobalt Chromium - All Sizes USFDA approved 1
5 Sirolimus Coated Drug Eluting Stent with Durable polymer - Cobalt Chromium - All Sizes CE approved 1
6 Sirolimus Coated Drug Eluting Stent with Durable polymer - Cobalt Chromium - All Sizes DCGI approved 1
7 Sirolimus coated drug eluting Polymer-free Coronary Stent system - All sizes USFDA approved 1
8 Sirolimus coated drug eluting Polymer-free Coronary Stent system - All sizes CE approved 1
9 Sirolimus coated drug eluting Polymer-free Coronary Stent system - All sizes DCGI approved 1
10 Everolimus Coated Drug Eluting Stent with Durable polymer - Cobalt Chromium Date of Certificate of approval for use in or after January 2008 Balloon Material: Single Layer Pebax RBP: ≈16 atm All Sizes USFDA approved 1
11 Everolimus Coated Drug Eluting Stent with Durable polymer - Cobalt Chromium Date of Certificate of approval for use in or after January 2011 Balloon Material: Dual layer Pebax RBP: ≈18 atm All Sizes USFDA approved 1
12 Everolimus Coated Drug Eluting Stent with Durable polymer - Cobalt Chromium Date of Certificate of approval for use in or after January 2012 Balloon Material: Multi layer Pebax RBP: ≈18 atm All Sizes USFDA approved 1
13 Everolimus Coated Drug Eluting Stent with Durable polymer - Cobalt Chromium Flexible Distal tip, Coaxial positioning system, ultra low tip profile All Sizes USFDA approved 1
14 Everolimus Coated Drug Eluting Stent with Durable polymer - Cobalt Chromium Date of Certificate of approval for use in or after May 2018 Balloon Material: Single Layer multifold Pebax RBP: ≈16 atm All Sizes USFDA approved 1
15 Everolimus Coated Drug Eluting Stent with Durable polymer - Cobalt Chromium Date of Certificate of approval for use in or after December 2020 Balloon Material: Single Layer multifold Pebax RBP: ≈16 atm All Sizes USFDA approved 1
16 Everolimus Coated Drug Eluting Stent with Durable polymer - Cobalt Chromium - All Sizes CE approved 1
17 Everolimus Coated Drug Eluting Stent with Durable polymer - Cobalt Chromium - All Sizes DCGI approved 1
18 Everolimus Coated Drug Eluting Stent with Durable polymer - Platinum Chromium Date of Certificate of approval for use in or after November 2013 Connectors: 4 on proximal end and 2 throughout stent body Proximal Shaft PTFE Coating All Sizes USFDA approved 1
19 Everolimus Coated Drug Eluting Stent with Durable polymer - Platinum Chromium Date of Certificate of approval for use in or after September 2018 Connectors: 4 on proximal end and 2 throughout stent body Proximal Shaft PTFE Coating with Laser cut Hypotube technology All Sizes USFDA approved 1
20 Everolimus Coated Drug Eluting Stent with Durable polymer - Platinum Chromium - All Sizes CE approved 1
21 Everolimus Coated Drug Eluting Stent with Durable polymer - Platinum Chromium - All Sizes DCGI approved 1
22 Everolimus Coated Drug Eluting Stent with Bioabsorbable polymer - Platinum Chromium base Date of Certificate of approval for use in or after October 2015 Connectors: 4 on proximal end and 2 throughout stent body Proximal Shaft PTFE Coating with Laser cut Hypotube technology All Sizes USFDA approved 1
23 Everolimus Coated Drug Eluting Stent with Bioabsorbable polymer - Platinum Chromium base Date of Certificate of approval for use in or after May 2020 Connectors: 4 on proximal end and 2 throughout stent body Proximal Shaft PTFE Coating. Enhanced Laser cut Hypotube technology All Sizes USFDA approved 1
24 Everolimus Coated Drug Eluting Stent with Bioabsorbable polymer - Platinum Chromium base Date of Certificate of approval for use in or after January 2021 Connectors: 4 on proximal end and 3 throughout stent body Proximal Shaft PTFE Coating. All Sizes USFDA approved 1
25 Everolimus Coated Drug Eluting Stent with Bioabsorbable polymer - Platinum Chromium base Date of Certificate of approval for use in or after September 2023 Connectors: 4 on proximal end and 2 throughout stent body Proximal Shaft PTFE Coating. All Sizes USFDA approved 1
26 Everolimus Coated Drug Eluting Stent with Bioabsorbable polymer - Platinum Chromium base - All Sizes CE approved 1
27 Everolimus Coated Drug Eluting Stent with Bioabsorbable polymer - Platinum Chromium base - All Sizes DCGI approved 1
28 Zotarolimus Coated Drug Eluting Stent with Durable polymer - Cobalt Chromium base Date of Certificate of approval for use in or after January 2012 All Sizes USFDA approved 1
29 Zotarolimus Coated Drug Eluting Stent with Durable polymer - Cobalt Chromium base - All Sizes CE approved 1
30 Zotarolimus Coated Drug Eluting Stent with Durable polymer - Cobalt Chromium base - All Sizes DCGI approved 1
31 Zotarolimus Coated Drug Eluting Stent with Durable polymer - Platinum Iridium/Cobalt Chromium base Date of Certificate of approval for use in or after January 2017 All Sizes USFDA approved 1
32 Zotarolimus Coated Drug Eluting Stent with Durable polymer - Platinum Iridium/Cobalt Chromium base Date of Certificate of approval for use in or after September 2022 Balloon Material: Dual Flex All Sizes USFDA approved 1
33 Zotarolimus Coated Drug Eluting Stent with Durable polymer - Platinum Iridium/Cobalt Chromium base - All Sizes CE approved 1
34 Zotarolimus Coated Drug Eluting Stent with Durable polymer - Platinum Iridium/Cobalt Chromium base - All Sizes DCGI approved 1
35 Sirolimus Coated Drug Eluting Stent with Bioabsorbable Polymer - All Sizes USFDA approved 1
36 Sirolimus Coated Drug Eluting Stent with Bioabsorbable Polymer - All Sizes CE approved 1
37 Sirolimus Coated Drug Eluting Stent with Bioabsorbable Polymer - All Sizes DCGI approved 1
38 Coronary Balloon Mounted Covered Stent (Monorail) - Sandwich Stent Design Wire Diameter: 0.014" compatible Diameter: 2.5 to 6 mm, Length: 12 to 30 mm USFDA approved / HDE issued by USFDA 1
39 Coronary Balloon Mounted Covered Stent (Monorail) - Sandwich Stent Design Wire Diameter: 0.014" compatible Diameter: 2.5 to 6 mm, Length: 12 to 30 mm CE approved 1
40 Coronary Balloon Mounted Covered Stent (Monorail) - Sandwich Stent Design Wire Diameter: 0.014" compatible Diameter: 2.5 to 6 mm, Length: 12 to 30 mm DCGI approved 1
41 Coronary Balloon Mounted Covered Stent (Monorail) - Single Stent Design Wire Diameter: 0.014" compatible, Crossing profile must be upto 1.25 mm or less Diameter: 2.5 to 6 mm, Length: 12 to 30 mm USFDA approved / HDE issued by USFDA 1
42 Coronary Balloon Mounted Covered Stent (Monorail) - Single Stent Design Wire Diameter: 0.014" compatible, Crossing profile must be upto 1.25 mm or less Diameter: 2.5 to 6 mm, Length: 12 to 30 mm CE approved 1
43 Coronary Balloon Mounted Covered Stent (Monorail) - Single Stent Design Wire Diameter: 0.014" compatible, Crossing profile must be upto 1.25 mm or less Diameter: 2.5 to 6 mm, Length: 12 to 30 mm DCGI approved 1
44 Sirolimus Eluting BioResorbable Vascular Scaffold System - All Sizes USFDA approved 1
45 Sirolimus Eluting BioResorbable Vascular Scaffold System - All Sizes CE approved 1
46 Sirolimus Eluting BioResorbable Vascular Scaffold System - All Sizes DCGI approved 1
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Tender Document - Coronary Stent.pdf
Technical Compliance Sheet - Coronary Stent.xls
XLS
Revised Technical Compliance Sheet - Coronary Stent.xls
CORRIGENDUM
Corrigendum-01 (Clarification).pdf
CORRIGENDUM
Corrigendum-01 (Amendment-Addendum).pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].