| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.1 LAccepted-AOC | L1 | Accepted-AOC L1 AMONGST BONAFIDE BIDDERS | |
| 2 | L2₹34.1 L+₹37,406 (1.11%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L2 | Rejected-Finance NON BONAFIDE. QUOTED BELOW MINIMUM WAGES | |
| 3 | L3₹34.8 L+₹1.1 L (3.15%)Rejected-Finance FLAT NO 151 BLOCK NO 1 DIAMOND SQUARE CGHS LTD PLOT NO 13A SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L3 | Rejected-Finance NON BONAFIDE. QUOTED BELOW MINIMUM WAGES | |
| 4 | L4₹35.4 L+₹1.7 L (4.96%)Rejected-Finance | L4 | Rejected-Finance NON BONAFIDE. QUOTED BELOW MINIMUM WAGES | |
| 5 | L5₹35.6 L+₹1.9 L (5.65%)Rejected-AOC 39 ANAND INDUTRIAL ESTATE MOHAN NAGAR GHAZIABAD UTTAR PRADESH 201007 | GHAZIABAD | UTTAR PRADESH | 201007 | L5 | Rejected-AOC L2 AMONGST BONAFIDE BIDDERS |
Tender Value
₹44.8 L
EMD Value
₹89,600
Closing Date
28 Sept 2020, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
OUTSOURCING OF SERVICES FOR MANNING AND OPERATION OF LIFTS IN SERVICE OFFICERS FLAT A, B, C AND D BLOCK DRDO RESIDENTIAL AREA UNDER GE I RND DELHI
2020_MES_362451_1
GE/RND-43/DLI/2020-2021
Open Tender
Manpower Supply
Item Rate
330 days
DELHI
Class D, Cat d(v)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹89,600
Yes
25 Nov 2020
20 Jul 2020
1 Oct 2020
20 Jul 2020
28 Sept 2020
16 Sept 2020
Amount
PART-1 OPERATION AND MAINTENANCENANCE OF E/M INSTALLATION Manning & Operation of electrically operated lift of capacity 08 passangers - 01 No, suitable for G+5 (Ground+5 floors) installed at A BLOCK to be operated in the three shift per day (0600hrs to 1400 hrs Ist Shift, 1400 hrs to 2200 Hrs 2nd Shift, 2200 hrs to 0600 Hrs 3rd Shift) from Monday to sunday including gazetted holidays by deploying one trained Operator/Mechanic (skilled) per shift complete all as specified and as directed
Manning & Operation of electrically operated lift of capacity 08 passangers - 01 No, suitable for G+5 (Ground+5 floors) installed at B BLOCK to be operated in the three shift per day (0600 hrs to 1400 hrs Ist Shift, 1400 hrs to 2200 Hrs 2nd Shift, 2200 hrs to 0600 Hrs 3rd Shift) from Monday to sunday including gazetted holidays by deploying one trained Operator/Mechanic (skilled) per shift complete all as specified and directed
Manning & Operation of electrically operated lift of capacity 08 passangers - 01 No, suitable for G+5 (Ground+5 floors) installed at C BLOCK to be operated in the three shift per day (0600hrs to 1400 hrs Ist Shift, 1400 hrs to 2200 Hrs 2nd Shift, 2200 hrs to 0600 Hrs 3rd Shift) from Monday to sunday including by deploying one trained Operator/Mechanic (skilled) per shift complete all as specified and directed
Rate required to be quoted for executing the work as described in Ser item No 1.00 to 3.00 above
Workers wage per person as per existing rules
ESIC (Employees state insurance contribution) as mentioned in tender document
Bonus as mentioned in tender documents
Overhead & Profit on Ser No 4.01 to 4.03
LWC as mentioned in tender documents for ser No 4.01 to 1.04
GST as mentioned in tender documents ser No 4.01 to 4.04
Notes : Rate quoted by the contractor shall deemed to be included the following :- (i) Operator cum mechanic (skilled) shall be of Diploma/ITI passed with having minimum one year fraining certificate in relevent trade shall be employed for each shift.. (ii) It is an express condition of the contract that tenderers are required to quote their rates duly considered minimum applicable as per policy wages of the tradesmen intended in the tender, as in force on the end date of bid submission. It shall be deemed that quoted rates are based on minimum wages notified by the concerned authority for the station i.e Govt of India/State Govt/Union Teritory, whichever is higher including all statutory provisions such as EPF, GST, ESIC , Bonus, labour welfare cess (LWC) and contractor's overhead & profits etc as applicable. (iii) In case the rates quoted by tenderer are less than the notified minimum wages as on bid submission end date including all statutory provisions such as EPF, GST, ESIC, Bonus, labour welfare cess (LWC) and contractor's overhead & profits etc as applicable, his tender will be treated as non-bonafide and will not be considered for Acceptance. In such case, the lowest tender shall be determined amongst valid/bonafide bids only. (iv) The firm/contractor shall be solely and fully responsible to his reprsentative/personal for any accident/damage during maintenance/operation/health related liabilities/compensation, penelty etc on this account and shall have no liability in this regrd. (v) T&P required such as spanner set, wrench, screw driver set, testing lamp, drilling machine and multimeter, tong tester, megger etc as well as protective devices (shoes, helmet etc) shall be provided by the contractor at no extra cost. (vi) Contractor shall be responsible to maintain log books, duty roster attendance register and spare dor repair/renewal. (vii) Operator shall neither leave the installations without prior permission of JE/Engineer-in-Charge. Proper handing/taking over to the next operator will be made.
(viii) Two sets of uniform and shoes shall be provided to each operator by the contractor. (ix) Cleaning of complete lift, machine room of lift, greasing, tightening of nuts , bolts will be carried out by the operator employed by the contractor. (x) First Aid box will be provided by contractor at each installation. (xi) Increased wages including all other benefits in compliance of statutory provisions shall be paid to workers by the contractor. No other claim whatsoever shall be admissible on this account and the bidders shall consider this aspect while quoting their rates. It must be noted that in compliance of the statutory provisions, the increase will be passed over to the workers. (xii) Any consumble item shall be issued by department free for fixing/filling. The contractor shall collect and transport the same from E/M store yard to the requisite installations within 24 Hours at his own cost and arrangement. Proper record for issue & receipt of oil shall be maintained by the Engineer-in-Charge & contractor. (xiii) The Contractor shall not pay wages lower than the latest notified minimum wages in force to their workmen/ tradesmen including all other benefits in compliance of statutory provisions. Bidders shall consider this aspect while quoting their rates.
PART-II : REPAIR/MAINT WORK Excavation in trenches in soft/loose soil not exceeding 1.5m depth & not exceeding 1.5m in width for taking out and relaying of LT Cables & other connected items complete all as specified and directed
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm thick as in soft/loose soil complete all as specified and as directed.
Removing surplus excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed.
Supply & laying dry fine sand for cushioning of underground cable laid in trenches/duct complete all as specified and as directed
Supply and laying in trenches burnt brick sub class 'B' standard size for cable protection keeping width of the brick parallel to the length of the cable all as specified and directed.
Excavation in trenches in hard/dense soil not exceeding 1.5m depth & not exceeding 1.5m in width over energised LT cables for taking out and relaying of LT Cables complete all as specified & directed
Supply and laying in repair XLPE insulated heavy duty electric cables screened PVC bedded, galvanised steel strip or wire armoured, electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 Core including taking down old unserviceable cable complete all as specified and as directed
Supply and laying in repair XLPE insulated heavy duty electric cables screened PVC bedded, galvanised steel strip or wire armoured, electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 Core including taking down old unserviceable cable complete all as specified and as directed
Supply and laying in repair XLPE insulated heavy duty electric cables screened PVC bedded, galvanised steel strip or wire armoured, electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 Core including taking down old unserviceable cable complete all as specified and as directed
Supply and laying in repair XLPE insulated heavy duty electric cables screened PVC bedded, galvanised steel strip or wire armoured, electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 Core including taking down old unserviceable cable complete all as specified and as directed
Supply and laying in repair XLPE insulated heavy duty electric cables screened PVC bedded, galvanised steel strip or wire armoured, electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 Core including taking down old unserviceable cable complete all as specified and as directed
Supply and laying in repair XLPE insulated heavy duty electric cables screened PVC bedded, galvanised steel strip or wire armoured, electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 150 Sqmm 3.5 Core including taking down old unserviceable cable complete all as specified and as directed
Supply and laying in repair XLPE insulated heavy duty electric cables screened PVC bedded, galvanised steel strip or wire armoured, electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 240 Sqmm 3.5 Core including taking down old unserviceable cable complete all as specified and as directed
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron strip of 25x4 mm by means of Copper nuts, bolts and washers. Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a) GI strip of size 25mm x 4mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required 25x4 mm galvanised iron strip including taking down old unserviceable complete all as specified and directed
M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregates for repairing of LT pole foundation etc including filling in road cuts/ hard standing etc including demolition of old u/s complete all as specified and as directed.
Supply and laying GI pipe light grade in repair of 50mm dia including fittings laid in trenches or under road crossing for protection of UG cable complete all as specified & directed
Supply and laying GI pipe light grade in repair of 80mm dia including fittings laid in trenches or under road crossing for protection of UG cable complete all as specified and directed.
M&L for boring of holes under road, pavement, hard standing by trenchless techonology using ultra sound technique/mannually/mechanically and necessary machine grade including making necessary excavation upto 1.5 mtr deep on both side of road for making holes and for inserting 80mm dia GI Pipe complete all as specified and directed
Supply & Fix in repair of ARD Battery for lifts 12 Volts 7 AH all as specified and directed
Supply & Fix in repair of Steel wire rope 13 MM dia & Existing length for lifts all as specified and directed
Supply and fix in repair of MCCB, 4 pole, 160 Amp, 36 KA with micro processor release and Adjustable overload setting , 50 Hz, 415 V complete all as specified.& directed
Supply and fix in repair of MCCB, 4 pole, 100 Amp, 36 KA with micro processor relese and Adjustable overload setting , 50 Hz, 415 V all as specified.
Supply & Fix in repair recessed mounted deep recessed adjustable down light 6 watt all as specified and directed Make : Bajaj.Cat No BRDCSL 6W WH or equivlent make approved from list of makes
M/s Adhikari construction co.
BRIJ MOHAN LAL AND CO.
Choice india
M/s Sombansi Enviro Engg Pvt Ltd
Pradeep Bros
jay maa engineers
M/s Dhapola Elevator and Engineering
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .