Loading…
Loading…
Tender ID
Tender Value
₹13.5 L
EMD Value
₹33,700
Closing Date
19 Feb 2026, 5:00 pmClosed
Executive Engineer,PMU ,Kattakada.
O/o Executive Engineer,PMU,Kattakada
Construction Of 11 KV OH Line with Covered Conductor at Alachakonam-Poozhanadu Hospital-Chenadu under Electrical Section, Ottasekharamangalam of Electrical Division, Kattakada under Electrical circle Kattakada.
2026_KSEB_833757_1
EE/PMU(KTDA)/ET-20/2025-26 dated 05.02.2026
Open Tender
Electrical Works
Percentage
120 days
Ottasekharamangalam
7 documents required · 7 mandatory
₹5,900
₹33,700
20 Feb 2026
5 Feb 2026
24 Feb 2026
5 Feb 2026
19 Feb 2026
5 Feb 2026
5 Feb 2026 - 12 Feb 2026
Fitting one Additional V cross arm in existing single pole incl. conveyance of materials.
Fitting one Additional 75x40mm, 1.8m Channel cross arm in existing single pole incl. conveyance of materials.
Transporting poles by hired vehicle to a distance upto 5km and carrying upto 4 poles excluding loading & unloading.
Transporting LT ABC by hired vehicle to a distance up to 5 km and carring up to 2 drum including loading and un loading using crane
Providing one Coil Earth using GI earth wire, digging separate pit at standard distance away from the pole/structure & backfilling.
Providing one Earth using earth pipe incl. digging & backfilling pit and supply of charcoal, salt, sand etc.
Additional rate for providing one disc set on any type of HT pole for making cut point.
Fitting one set AB switch and giving connection
Fitting one Additional 2.4m/3m Channel cross arm (100x50x6mm), in existing 11kV DP incl. conveyance of materials.
Drilling hole of various sizes on existing Channel/Cross Arm.
Fitting and erecting one HT DP using PSC pole in position incl. fitting 2 channel cross arms, digging & back filling pit, drawing earth leads.
Loading HT PSC pole from the stacking place and unloading the same at work site (transport by vehicle).
Fitting and providing one HT Fly stay for 11kV pole using HT PSC pole incl. digging & back filling pits.
Fitting and erecting one HT PSC Pole in position incl. fitting cross arm, digging & back filling pit, drawing earth leads.
Fitting and erecting one HT A type Pole in position incl. fitting cross arm, digging & back filling pit, drawing earth leads.
Loading HT A type pole from the stacking place and unloading the same at work site (transport by vehicle).
Providing concrete muffing (0.45x0.45x1.5m) inclusive of cost of all material (as per specification).
Dismantling one damaged LT PSC/RCC pole after disconnecting stays, strut etc. and stacking the same.
Dismantling (without damage) one km LT Sph 2 wire OH line, cross arms, insulators and stacking the conductors in rolls.
Dismantling (without damage) one km LT 3ph 4 wire OH line, cross arms, insulators and stacking the conductors in rolls.
Dismantling (without damage) one km LT additional conductor line, cross arms, insulators and stacking the conductors in rolls.
Dismantling one section fuse
Dismantling (without damage) one LT PSC/RCC pole after disconnecting stays, strut etc. and stacking the same.
Stringing of 1.1 kV Aerial bunched cable of size 3 x 70+ 1 x 16+1x 50 sqmm with bare/insulated Messenger through existing poles
Stringing one km LT Sph 2 wire line (Rabbit) incl. fitting cross arm etc. removing touchings and conveyance of materials.
Stringing one km LT 3ph 5 wire line (Rabbit for Ph and Weasel for N&St.main) incl. fitting cross arm etc. removing touchings and conveyance of materials.
Dismantling one ordinary street light/CFL/LED fitting from existing pole and refitting the same on newly erected pole and reconnecting.
Dismantling and reconnecting Sph service connection from the OH line incl. lowering down the WP portion.
Dismantling and reconnecting 3ph service connection from the OH line incl. lowering down the WP portion.
Providing/Inserting 2 line spacer on the existing LT OH line.
Providing/Inserting 3 line spacer on the existing LT OH line.
Erection of suspension clamp for LT ABC of any size
Erection of Anchor clamp / dead end clamp for LT ABC of any size
Installation of Insulation piercing connector for main to service line main :16-95 sqmm, Tap : 4-35 sqmm
Installation of Insulation piercing connector for main to service line main :16-95 sqmm, Tap 16-95 sqmm
Singe Phase Satellite connectors upto 4 service main connections (25-95 ABC/2.5-25 sqmm SM wire-2No)
Fitting of one No. pole top service connection box of standard size (up to 4 way) using ss strap/B&N of suitable size in to the PSC/A poles at the standard height excluding giving connections
Transferring LT Sph 2/3 wire OH line to newly erected HT/LT pole and refitting all items to the new pole.
Transferring LT 3ph 4/5 wire OH line to newly erected HT/LT pole and refitting all items to the new pole.
Cutting trees beyond 60cm but upto and incl. 120cm girth, cutting branches, removing root completely and stacking (where space for falling trees is not enough).
Cutting trees beyond 30cm but upto and incl. 60cm girth, cutting branches, removing root completely and stacking (where space for falling trees is not enough).
Additional rate for excavation of one Pit for HT Pole/HT Stay in Laterite.
Fitting and providing one HT Stay for 11kV pole incl. digging & back filling pit.
Fitting and providing one Strut using HT PSC pole incl. digging & back filling pit.
Stringing of one km 3 PH 11kV line with XLPE Insulated ACSR Raccoon
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.09 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.13 MB
PartIOtsm.pdf
Tender Documents • 0.77 MB
PartIIOtsm.pdf
Tender Documents • 0.50 MB
BOQ_1402348.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .