Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 CrAccepted-AOC 00 00 NAPASAR ROAD NENO KA BASS BIKANER RAJASTHAN BIKANER RAJASTHAN 334022 UDYAM RJ 08 0001676 | BIKANER | RAJASTHAN | 334022 | ₹7.5 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹8.3 Cr+₹84.7 L (11.3%)Rejected-Finance | ₹8.3 Cr+₹84.7 L (11.3%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹8.4 Cr+₹88.0 L (11.7%)Rejected-Finance C 33 3971 GALI NO 6 JALANDHAR CANTT 144005 | JALANDHAR | JALANDHAR | PUNJAB | 144005 | ₹8.4 Cr+₹88.0 L (11.7%) | L3 | Rejected-Finance NOT LOWEST |
| 4 | L4₹8.4 Cr+₹88.0 L (11.7%)Rejected-Finance WZ 487 2 MS BLOCK HARI NAGAR NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | ₹8.4 Cr+₹88.0 L (11.7%) | L4 | Rejected-Finance NOT LOWEST |
Tender Value
₹5.7 Cr
EMD Value
₹6.1 L
Closing Date
18 Nov 2024, 6:00 pmClosed
HQ CE (AF) WAC PALAM
HQ CE (AF) WAC PALAM, DELHI CANTT-10
COMPLETION OF BALANCE WORK OF STATION AUDITORIUM AT AF STN AMBALA (RISK AND COST)
2024_MES_673247_1
CEWAC/AMB/T-11/2024-25
Open Tender
Civil Works
Lump-sum
420 days
GE (AF) AMBALA
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
GE (AF) AMBALA
₹6.1 L
Yes
31 Jan 2025
11 Sept 2024
25 Nov 2024
11 Sept 2024
18 Nov 2024
5 Nov 2024
Amount
SCHEDULE `A' PART - I (Building Works) is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only.
Construction of balance work of Auditorium building, including pile foundation and rectification of defects work if any complete all as specified as shown on drgs. Quantam of approx balance work is 57%. For details, ref Sch 'A' notes / annexures, However Tenderers are adviced to visit site before quoting tender to assess the actual balance work and rectification of defects if any.
Construction of balance work of AC plant room S/S with permanent specification complete all as specified as shown on drg. Quantam of approx balance work is 20.60%. For details, ref Sch 'A' notes / annexures, However Tenderers are adviced to visit site before quoting tender to assess the actual balance work and rectification of defects if any.
Construction of balance work of Pump house bldg S/S with permanent specification complete all as specified as shown on drg. Quantam of approx balance work is 20.60%. For details, ref Sch 'A' notes / annexures, However Tenderers are adviced to visit site before quoting tender to assess the actual balance work and rectification of defects if any.
Construction of balance work of static water tank 50,000 ltr capacity with permanent specification complete all as specified and as shown on drawings. Quantam of approx balance work is 15%. For details, ref Sch 'A' notes / annexures, However Tenderers are adviced to visit site before quoting tender to assess the actual balance work and rectification of defects if any.
Construction of valve chamber of internal size 900 mm x 900mm x 900mm in brick work with sub class bricks in cement 1:4 including necessary PCC in foundation 10 cm thick and coping, plastering 15mm thick in CM 1:4, MS sheet cover 3mm thick MS angle iron frame with 50x4 mm including hinges, lifting handle and locking including painting with one coat of primer and two coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
Construction of valve chamber of internal size 750 mm x 750mm x 750mm in brick work with sub class bricks in cement 1:4 including necessary PCC in foundation 10 cm thick and coping, plastering 15mm thick in CM 1:4, MS sheet cover 3mm thick MS angle iron frame with 50x4 mm including hinges, lifting handle and locking including painting with one coat of primer and two coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
NOTE: Schedule ‘A’ Part II to XII under Ser No. 2.01 to 2.10 are Prepriced by MES.
Lump sum price worked out by the Contractor for “SITE CLEARANCE AND EARTH WORK” as listed in Schedule ‘A’ Part II
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION"” as listed in Schedule ‘A’ Part III
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY"” as listed in Schedule ‘A’ Part IV
Lump sum price worked out by the Contractor for "SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part V
Lump sum price worked out by the Contractor for “AREA DRAINAGE WORK” as listed in Schedule ‘A’ Part VI
Lump sum price worked out by the Contractor for “ROAD, PATH AND HARDSTANDING"” as listed in Schedule ‘A’ Part VII
Lump sum price worked out by the Contractor for “SECURITY WALL, GATE & FENCING” as listed in Schedule ‘A’ Part VIII
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY ” as listed in Schedule ‘A’ Part IX
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIC SUPPLY ” as listed in Schedule ‘A’ Part X
Lump sum price worked out by the Contractor for “LIGHTNING PROTECTION” as listed in Schedule ‘A’ Part XI
SCHEDULE `A' PART - XIII MISC ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only.
S&F of cast iron sluice valve 80mm bore PN-1 including joints and joiting material complete all as specified and directed
EXTERNAL ELECTRIFICATION
Supply, design, loading, unloading, Installation testing and commissioning of outdoor type floor mounted step down transformer 11000/433 volts (at no load) capacity 315 KVA, AC 3 Phase 50 Hz double copper wound oil immersed laminated iron core naturally cooled with external cooling tube core type delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector symbol DYn-11 (Vector group) with netural brought out separately for earthing inlcuding off load changing tap arrangements on HT side winding upto +/- 7.5% in steps of +/- 2.5% each complete with first filling oil upto appropriated level and LT side suitable for connection with bus bar trunk. The maximum temperature rise should not exceed 50 degree celsius in oil and 55 degree celsius in HT/LV winding rom ambiant temp when measured by resistance method after continious full load run in ambient temp of 40 degree celcius. The trasnformer shall confirm IS:1180 (part-I) level I and latest relavent IS and DCBC marked and all as directed by Engr-in-Charge at site. Note : (i)Pre dispatch inspection at factory premises shall be carried out by rep of AO and cost of the inspection shall deemed to be included in the quoted rate of this item (ii) The cost of foundation/plinth of transformer as per manufacturer recommendation shall deemed to be included in quoted rates.
Supply and fixing of GI tubing light grade of 50 mm dia for cable protection on pole/wall/floor/ or in trenches and drain etc complete with necessary clamp, nut, bolts and washers and socket and making good the disturbed surface of wall , floor or roof etc all as specified and directed, (Note : MS clamp, nut, bolts and washers measured and paid seperately)
Supply and fixing of GI tubing light grade of 80 mm dia for cable protection on pole/wall/floor/ or in trenches and drain etc complete with necessary clamp, nut, bolts and washers and socket and making good the disturbed surface of wall , floor or roof etc all as specified and directed, (Note : MS clamp, nut, bolts and washers measured and paid seperately)
M&L for earthing with GI earth plate size 600x600x6mm buried vertifically in ground to depth not less than 2.25 mtr below normal ground level, with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanized earth strip 25 x 4 mm size as earthing lead by means of bolts, check nuts & washers of galvanized iron or steel shown in electrical plate No.3, connected to earthing test point all as specified or indicated including adequate quantity of charcoal dust mixed with commercial salt 15cm in alternate layers from bottom of electrode plate to top edge and refilling only filtered fine soil up to ground level of earth pit including provision of connecting 20 mm dia GI light grade pipe for watering from GI earth plate to earth pit chamber and protection pipe 40mm dia GI light grade all as specified and directed by Engineer-in-Charge. Note: The rate for protection pipe 40 mm dia and watering pipe 20mm dia light grade ,funnel,wire mesh ,PCC 1:3:6 type C-2 in chamber ,RCC 1:2:4 type B-1 in pit cover ,excavation and earth work shall deemed to be included in the quoted rates.
All as per srl item No.4.04 here-in-before but using GI wire 4mm dia as earth lead
Material and Labour for LED street light fittings 90 watt system wattage should not be more than 90 watt and system lumen should not be less than 9000 lumen complete including cutting, welding, drilling holes, nut bolts, washer, etc all as directed by Engineer in charge NOTE: (i) For all types of LED fittings & luminaire should be of same manufacturer (ii) LM 79 certificate for all light fittings shall be submitted by the contractor before fixing at site or taking payment against material. (iii) System efficiency should be more than 100 lummens/watt. (iv) CRI should be 80. (v) THD should be less than 20%. (vi) PF should be more than 0.9
Material & Labour fixing new street light bracket made out of GI pipe medium grade 40 mm dia approx length not less than 150cm bent to shape including new clamps made out of MS flat of size 32x5mm thick including cutting, welding, drilling holes, nut bolts, washer, etc including two coats, aluminium paint over one coat of red oxide primer on MS work complete all as directed.
Supply, installation, testing and commissioning of Main LT panel suitable for 3 Phase 415 volt of suitable size outdoor type double door front and rear openable factory made CPRI approved made out 3.15 mm thick CRCA sheet with angle iron frame of size 50 x 50 x6 mm cubical type complete with , copper bus bar 1000 Amp, with IP 65 as per IS 13947 , complete all as specified and directed with following- INCOMING (a) ACB 4 pole 630 Amps Electrical Draw out with all protection including ON, OFF, Trip indication and settings - 01 No (b) Multi functional meterindicating voltage and current -01No. (c) RYB phase indicator lamps LED type - Set of 3. OUTGOING (a) MCCB 320 Amps four pole 415V 25 KA with thermal settings - 02 Nos (b) MCCB 160 Amps four pole 415V 25 KA with thermal settings - 01 No (c) MCCB 100 Amps four pole 415V 16 KA with thermal settings - 02 Nos NOTE : (i) All MCCB should be thermal adjustable type (ii) Group I make shall be followed (iii) the ACB should be manual draw out type with breaking capacity of 50KA(ics=Icu=Icw for 1sec) microprocessor release for O/L, S/C and E/F protection with LED screen, fault history, percentage of load be graph on each phase, ACB compliance to 60947-2 (iv) MCCB should be Ics=100 % Icu)
Supply, installation, testing and commissioning of Main LT panel suitable for 3 Phase 415 volt of suitable size outdoor type double door front and rear openable factory made ,CPRI approved type made out 3.15 mm thick CRCA sheet with angle iron frame of size 50 x 50 x6 mm cubical type complete with , copper bus bar 400 Amp, with IP 65 as per IS 13947, complete with following- INCOMING (a) On load changeover switch front operated four pole of capacity 250 amps (b) MCCB 250 Amps four pole 415V 25 KA with thermal settings - 01 Nos (c) Multi functional meterindicating voltage and current -01No (d) RYB phase indicator lamps LED type - Set of 3. OUTGOING (a) MCCB 63 Amps four pole 415V 16 KA with thermal settings - 04 Nos all as specified and directed NOTE : (i) All MCCB should be thermal adjustable type (ii) Group I make shall be followed(iii) The MCCB should be Ics=100% Icu
Supply instal, testing and commissioning of Post top energy saving environmental friendly, long life aesthetically designed with good indirect symmetrical light distribution die cast aluminum land escape IP 65 luminaries with high power COB LED as light source of 35 watt, 6500K suitable for 80mm dia pipe (MS pipe, medium grade 80mm dia of length 7.5 feet will be included in the quoted rates) complete all specified and as directed NOTE : (i) For all types of LED fittings & luminaire should be of same manufacturer (ii) LM 79 certificate for all light fittings shall be submitted by the contractor before fixing at site or taking payment against material. (iii)System efficiency should be more than 90 lummens/watt. (iv) CRI should be 80. (v) THD should be less than 20%. (vi) PF should be more than 0.9
Supply, laying, jointing and testing cable insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable(heavy duty) laid in trenches and through ducts with aluminium conductor 1100 Volt Grade of size 10 Sqmm 4 core including necessary joint materials wherever applicable complete all as specified and directed by Engr-in-Charge.
LIGTNING PROTECTION
M&L earthing complete with GI earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at depth not less than 1.5 metre below normal ground level surrounded from all sides by15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using GI strip 32 x 6mm by means of bolts, nuts, check nuts & washers of galvanized iron and protected by light grade 40 mm dia GI pipe connected to main switch board or main control board and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1:2:4 type B2 including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown in electrical plate No. 3 of SSR Part-I Note : (i) The unit rate shall include for protection pipe, GI water pipe, wire mesh, funnel, excavation, RCC pit cover, PCC, Test point, 32x6mm GI strip from top of earth plate upto 5 metre above ground level . (ii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fitting junction. Elbow etc. shall be deemed to be included in the unit rate. (iii) RCC pit cover shall be precast of RCC 1:2:4, type B-1, 80mm thick reinforced with XPM weighing not less than 4 Kg/sqm in lieu of cast iron cover.
S&F GI tubes medium grade with all fittings 40mm dia one metre length including by making PCC cube of type B-1 i.e. 1:2:4 using 20mm graded stone aggregate for making block of size 30cmx30cmx30cm and put it on top of the roof as directed.
FENCING
M & L for 5.5 mtr wide steel gate incl cutting fabricating and welding complete as per drg and incl rail stoper etc and all as specified and directed
STANDBY ELECTRIC SUPPLY
Supply, install & commissioning of silent diesel engine driven Generating Set 320 KVA, 415 Volts, 3 phase 4 wire engine as per IS:10001/10002 and alernaator as per IS:13364 with AMF panel complete with relay panel for automatic starting on mains failure, with acoustic enclosure whether proof as per latest CPCB (center pollution control board) norms and noise level shell not exceed 75 db at a distance of 01 mtr and comprising of the following all as specified and directed . (a) diesel Engine generating power of suitable BHP at NTP turbocharged cooled engine inclusive of the following standard accessories :- (i) Radiator with fan(ii) Fly wheel(iii) Fly wheel housing complete with starter gear ring and coupling as per manufacturer. (iv) Air cleaner (v) By pass filter(vi) Coolant inhibitor (vii) Fuel pump(viii) Water pump(ix) Lub oil pump (x) Electric starter 24 Volts DC(xi) Battery charging generator (DC alternator)(xii) Residential silencer.(xiii) Flexible pipe for silencer(xiv) DC volt meter(xv) Water temp gauge lub oil pressure gauge(xvi) Speedo meter and Engine runing hrs meter(xvii) Display for fault(xviii) Suitable size of turbo charger
Earthing complete with galvanized steel earth plate electrodes 600x600x6 mm thick including 7.5 mtr GI strip 32x6 mm buried directly in ground earth (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to galvanised iron earthing strip 32mm x6mm thick by means of bolt nuts check nuts and washers and welding to strip and plate for better result of galvanized iron or steel all as specified & shown in electrical plate No.3 of MES SSR part-I 2009 connected to earth test point as specified and testing on completion including provision of 40 mm dia light grade pipe up to 7.5 mtr length as protection & watering pipe shall be 20 mm bore medium grade including all excavation & earth work in any type of soil incl PCC pit (1:3:6) type C-1 with RCC cover including charcoal , salt, funnel, all as directed at site.
INTERNAL ELECTRIFICATION
S&F of lamp holder insulated body with back plate for batten fitting with LED lamp 08 watt complete all as specified and directed by Engineer-in-Charge.
S&F energy saving decorative box type batten light fitting surface mounted complete with high efficiency PMMA diffuser soft glare free light LED lamp 20 watt suitable for 120 volts to 270 volts of system efficacy not less then 100 lumen/watt, with all accessories, pre-wired, including lamp and providing flexible copper wire, twin core cable complete all as specified and directed by Engineer-in-Charge
S&F LED bulkhead luminaire 10 watt, suitable for 120 volts to 270 volts of system efficacy not less then 100 lumen/watt, wall/surface mounted complete with with LED lamp 10 watt, with all accessories, pre-wired, including providing flexible copper wire, twin core cable complete all as specified and directed by Engineer-in-Charge.
S&F LED sleek mirror light fitting 05 watt provided with high output diffuser 2 ft long, suitable for 120 volts to 270 volts of system efficacy not less then 100 lumen/watt, complete with all accessories, pre-wired including lamp and providing flexible copper wire, twin core cable complete all as specified and directed by Engineer-in-Charge.
S&F LED security light fitting 45 watt, suitable for 120 volts to 270 volts of system efficacy not less then 100 lumen/watt, having uniformaty ratio 0.25, high pressure die cast aluminium housing, heat resistant toughened glass with frame, IP66 protection comlete with lamp & connected items and connection with suitable cable from ceiling rose to light fitting and fixing on GI pipe bracket made out of suitable dia GI pipe medium grade 1.2mtr long bent to shape and fixed on wall with flat iron clamps, nut, bolts washer etc all as specified and directed.
S&F Directional LED Spotlight luminaire 40 watt, suitable for 120 volts to 270 volts of system efficacy not less then 100 lumen/watt, recess mounted complete with , with all accessories, pre-wired, including providing flexible copper wire, three core cable complete all as specified and directed by Engineer-in-Charge.
S&F energy saving flood light luminaire with high pressure die cast housing with IP65 fitting complete with high efficiency PMMA diffuser light LED 60 watt suitable for 170 volts to 250 volts of system efficacy not less then 100 lumen/watt, with all accessories, pre-wired, including lamp and providing flexible copper wire, three core cable complete all as specified and directed by Engineer-in-Charge.
S&F energy saving LED deep downlight Ceiling light fitting LED 30 watt suitable for 170 volts to 250 volts of system efficacy not less then 100 lumen/watt,Color temp 3000K-6500K with all accessories, pre-wired, including lamp and providing flexible copper wire, three core cable complete all as specified and directed by Engineer-in-Charge.
S&F energy saving LED deep downlight Ceiling light fitting LED 20 watt suitable for 170 volts to 250 volts of system efficacy not less then 100 lumen/watt,Color temp 3000K-6500K with all accessories, pre-wired, including lamp and providing flexible copper wire, three core cable complete all as specified and directed by Engineer-in-Charge.
S&F LED strip light with glass protection floor edge & driver 12V - 3A for minimum 5M for step indicator
S&F Glow sign board with acrylic sheet 3 mm thick transparent sheet lettering "ENTRY" on Green, "EXIT" on red sheet suitable size and enclosure made with 2 mm thick MS sheet painted with black synthetic enamel paint and LED tube 2 No inside.
NOTE FOR ITEM N 7.03 TO 7.11 :- (i) For all types of LED fittings and luminaire should be same manufacturer. (ii) LM -79 cretificate for all light fittings shall be submitted by the contractor before fixing at site or taking payment against material.(iii) System efficacy should be more than 100 lummens / watt (iv) CRI should be 80 (v) THD should be less than 20% (vi) PF should be more than 0.95
Supply and fixing BLDC type ceiling fan 1200mm sweep complete with out fan regulator 230 volts (single phase) and provisioning of flexible copper cord of size 23/0.0076 of required length from ceiling rose or connector to ceiling fan for giving connection complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing exhaust fan metal body with louvers of size 300 mm sweep, 900 RPM 230 volts single phase AC supply complete with, bolt, nuts and washers, suitably embedded in the wall including making suitable opening and provisioning of flexible cord copper of size 23/0.0076 from ceiling rose to exhaust fan for giving connection complete all as specified and directed by Engineer-in-Charge.
Supply and fixing exhaust fan metal body with louvers of size 450 mm sweep, 900 RPM 230 volts single phase AC supply complete with, bolt, nuts and washers, suitably embedded in the wall including making suitable opening and provisioning of flexible cord copper of size 23/0.0076 from ceiling rose to exhaust fan for giving connection complete all as specified and directed by Engineer-in-Charge.
Supply and fixing wall mounting fan of size 450 mm sweep, 900 RPM 230 volts single phase AC supply complete with, bolt, nuts and washers, suitably fixed in the walland provisioning of flexible cord copper of size 23/0.0076 from ceiling rose to wall fan for giving connection complete all as specified and directed by Engineer-in-Charge.
Supply and fix stepped type electronic fan regulator flush type on the phenolic laminated sheet etc as required.
M & L for sub main wiring with two run of single core FRLS, PVC insulated, stranded, unsheathed cable copper conductor with size 04 Sqmm and drawing through non metallic PVC conduit concealed in wall including earth continuity conductor of size 04 Sqmm PVC insulated unsheathed stranded copper conductor FRLS cable and connected to earth dolly to be drawn in concealed PVC conduit including connecting to main board complete all as specified and directed by Engineer-in-Charge. Note:- Cost of conduit shall deemed to be included in the unit rate of this item.
M & L for sub main wiring with two run of single core FRLS, PVC insulated, stranded, unsheathed cable copper conductor with size 04 Sqmm and drawing through non metallic PVC conduit concealed in wall including earth continuity conductor of size 2.5 Sqmm PVC insulated unsheathed stranded copper conductor FRLS cable and connected to earth dolly to be drawn in concealed PVC conduit including connecting to main board complete all as specified and directed by Engineer-in-Charge. Note:- Note:- Cost of conduit shall deemed to be included in the unit rate of this item.
S&F MCB SP 6 to 32 Amps, 240 Volts complete all as specified and directed.
S&F MCB SPN upto 32 Amps ,240 Volts complete all as specified and directed.
S&F MCB TPN 100 Amps ,415 Volts complete all as specified and directed.
S&F Vertical sheet metal enclosures suitable for MCCB, FP and neutral, 08 ways with 200 Amps rated bus bar, 415 Volts double door type complete all as specified and directed by Engineer-in-Charge.
S&F MCCB FP 125 Amps, 25 KA415 Volts complete all as specified and directed.
M & L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to earth lead GI wire 4mm dia by means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvd iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of 2009. Note : RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqm in lieu of CI cover.
FIRE FIGHTING & ADDRESSABLE FIRE ALARM SYSTEM
Supply, installing, testing and commissioning of Electric driven Main Fire Pump consisting of Horizontally mounted centrifugal end suction type pump complete for delivery of 2850 ltrs/minute against a total head of 70 metres with bronze impeller complete with mechanical seal including squirrel cage induction motor suitable for 415 V, 50 Hz, AC supply rating for the above pump with synchronous speed of 2900 RPM T.E.F.C. type such as confirming to IP-55 and flexible coupling and coupling guard with the pump. Motor shall accept +/- 10% variation in voltage and +/- 3% variation in frequency common bed plate of fabricated mild steel channel or cast iron type complete all as specified and directed. Note: The cost of pump set , mounting bed, foundation and any earth work as per manufacturer recommendation deemed to be including in the quoted rate.
Supply, installing, testing and commissioning of Electric Driven automatic pressurization pump (Jockey) set for building up pressure in the system pipes it should be single stage pump capable of delivering 180 LPM of water against a total head of 70 mtrs horizontally mounted centrifugal end suction type jockey pump complete with bronze impeller & gland packed/mechanical seal including squirrel cage induction motor suitable for 415 V, 50 Hz, AC supply of 20 HP rating for the above pump with synchronous speed of 2900 RPM T.E.F.C. type such as confirming to IP-55 and flexible coupling and coupling guard with the pump. Motor shall accept +/- 10% variation in voltage and +/- 3% variation in frequency. Common bed plate of fabricated mild steel channel or cast iron type complete all as specified and directed. Note:The cost of pump set , mounting bed, foundation and any earth work as per manufacturer recommendation deemed to be including in the quoted rate.
Supplying, installation, testing & commissioning of the Diesel Engine Driven. Standby pump consisting of horizontally mounted centrifugal end suction type pump complete for delivery of 2850 ltrs/minute against a total head of 70 metres with bronze impeller complete with gland packing/ mechanical seal radiator cooled Diesel Engine developing 85 BHP for the above pump, flexible coupling and coupling guard with the pump common bed plate for mounting of the Engine and Pump, and vibration damping arrangement by cushy foot, Diesel Engine starting panel for starting of the engine automatically with a unit of battery of lead acid 12/24V, 150 Ah and battery charger as per specifications. Rate shall also include Exhaust pipe of required length and size to discharge exhaust gases exeternally with muffler, day oil tank of 200 ltrs capacity with first charge and hand pump set suitable reinforced cement concrete pump foundation of 1:2:4 ratio (1 cement 2 fine aggregate 4 coarse aggregate) includiang foundation bolts, washers as required. Fuel tank shall be of 1.6/2mm thick sheet factory made and shall have indications for Fuel Level, Foundation shall be finished with a coat of neat cement with 50 x 50 x 3mm thick MS angle edging and foundation shall be painted with enamel paint. Common bed plate for fabricated mild steel channel or cast iron type complete all as specified.
Supply and Install Booster pump set for 440V, 3 phase, 50 Hz confirming to IS-12469 : 1988 with CI casing bronze impeller and stainless steel shaft mounted on heavy duty bearings, 36 meter head discharge 450 LPM
Supply and fix MS flanged pipe 100mm NB heavy duty for riser duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer
All as per item 8.06 above but 80 mm dia Ms pipe
All as per item 8.06 above but 50 mm dia Ms pipe
All as per item 8.06 above but 32 mm dia Ms pipe
All as per item 8.06 above but 25 mm dia Ms pipe
Supply, fixing and testing of the following types of UL listed sprinkler heads. Sprinkler body in brass with glass bulb sensors complete in all respect as per latest specififications and standard. :
(i) Pendant type with quartzoid bulb, operating temperature 57 degree centigrade of 15 mm dia BSP and K Factor 80.
(ii) Side wall type with quartzoid bulb, operating temperature 57 degree centigrade of 15 mm dia BSP and K Factor 80.
Supply and fixing UL listed Flow Switch for 150 mm./100 mm dia on Sprinkler Header complete with flexible full bore paddle, U Clamp, NO/NC contact. Note :All as per latest specifications and standard.
Supply & fix fire hydrant landing valve SS type B (double head outlet) of 63 mm dia conforming to IS 5290
S & F of double flange CI sluice Gate valve PN-1.6 ,type complete with Matching Flanges Nut Bolts Gaskets etc as required for the following size.
(i) 100mm dia
Supply and fix hose box including hose reel of 20 mm size of 30 meter length complete with coupling branch pipe and nozzle , hose box shall be made out of MS sheet 2 mm thickness
Supply and fix MS cabinet (approx 750mm x 600mm x 450mm) to enclose fire brigade inlet connections fabricated from 16 gauge sheet with full front glass door and locking arrangement painted and mounted on masonry platform complete
Supply and fixing non-percolating, rubber reinforced lined fire hose pipe (as per IS: 636, Type B) of 63 mm dia. and length as descripbed below. The hose shall be rated for brust pressure of 35.7 Kg/Sqcm. Hose shall be complete with ISI marked brass male & female coupling (IS:903) bound rivetted to hose pipe with copper rivets & 1.5 mm copper wire.
(i) 15M long
Supply and fixing 63 mm dia. Instantaneous pattern branch short SS type, 20 mm dia. Nozzle conforming to IS:903, suitable for inter connection to hose pipe coupling complete as required.
Supply and Fixing Microprocessor based 1 loop capacity , Networkable analogue addressable type fire alarm control panel with 80 character LCD display, loop shall have a capacity of 318 analog addressable devices in one loop. Four access levels, capable of taking Flash Scan devices, flash EPROM sufficient numbers of programmable relay controls for controlling AHUs, pressurization fans, ventilation fans at fire pump room, monitoring of fire sprinkler and fire hydrant pump, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 2 hours during an emergency conditions as required. (UL 9th Edition Approved) Make:- Notifier, Minimax, Ravel, JCI
Supply and fixing Network Repeater Panel with 6 inch or 640-characters; The LCD shall Display all events / detectors, devices status of complete systems in the networked, The NRP shall be equipped with QWERTY Keypad. Mounting options include an annunciator box, and blank modules are required for mounting. Make:- Notifier, Minimax, Ravel, JCI
Supply and fixing A Very early warning Smoke Detection System with minimum sensitivity of .03% obscuration per foot required as per NFPA 318 / NFPA 76. Make:- Notifier, Minimax, Ravel, JCI
Supply and fixing Automatic Floating Sensitivity type Analog addressable Acclimate Photo thermal smoke detector with mounting based LED, Address Switch from 01-159, to programme the detectors, complete as required. (In Changing Environment Area) Make:- Notifier, Minimax, Ravel, JCI
Supply and fixing Analog addressable Rate of Rise Cum Fixed temperature detector with mounting based LED, Address Switch from 01-159 , to programme the detectors complete as required. Make:- Notifier, Minimax, Ravel, JCI
Supply and fixing Addressable Beam detector with 4 manual & 2 acclimate sensitivity settings. Address Switch to programme the detectors, complete as required. Make:- Notifier, Minimax, Ravel, JCI
Supply and fixing Addressable type fault for isolating shorted, dewired and loose circuits between two successive fault isolators with automatic resetting arrangement (base Model) Make:- Notifier, Minimax, Ravel, JCI
Supply and fixing Addressable control modules for Hooters / Sounders / Strobes etc Make:- Notifier, Minimax, Ravel, JCI
Supply and fixing Addressable control relay modules for AHU & stairs Pressurization Fan.Make:- Notifier, Minimax, Ravel, JCI
Supply and fixing Addressable Manual Glass Break Station complete as required. Make:- Notifier, Minimax, JCI
Supply and fixing Directional Sounders with 20 hz to 20 khz operating frequency with minimum 8 distinct sound patterns to indicate corridors, Exit doors, Move upward, move down ward etc. to direct Occupants for fast & safe Evacuation as specified in NFPA 72 - 2007 edition. Make:- Notifier, Minimax, JCI
Supply and fixing Integrated 8 channel Digital Voice Evacuation and 2 way Communication Fire Fighters System capable to supervision of all the speaker circuits, with required suitable amplifiers for 500 nos of speakers with minimum 20 zone control and accessories required to complete the system. The equipment shall be of same make as panel. Make:- Notifier, Minimax, JCI
Supply and fixing Fire panel supervised 70db-84db Ceiling Mounted Hooter Cum Speakers as specified & same make as of panel. Make:- Notifier, Minimax,JCI
Supply and fixing Fire panel supervised 70db-84db Wall Mounted Hooter Cum Speakers as specified & same make as of panel. Make:- Notifier, Minimax, JCI
Supply and fixing 2 way communication Fire Fighter's Telephone Jack Make:- Notifier, Minimax, JCI
Supply and fixing 2 way communication Fire Fighter's Handset Make:- Notifier, Minimax, JCI
Supply and fixing Water CO2 type Extinguisher in HP Mild Steel Cylinders ISI marked / approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully chaged with Foam compound complete in all respects including wall suspension braket and conforming to IS:15683. 9 Ltr Make Supremex, Ceasefire, Minimax
Supply and Fixing ” ABC Stored Pressure type Fire Extinguisher 6Kgs. capacity bearing BIS Mark for Fighting ABC Class of Fire. The Extinguisher will be Manufactured Strictly as per BIS: 15683:2006 bearing BIS. Mark. Powders and fitted with a PVC nozzle. ABC (MAP 90%). SHALL BE UL LISTED Valve with below mentioned additional facilities a) In built NRV on valve to cross check internal pressure. b) Operating temperature marking on valve. c) Automatic safety release valve. d) Year Of Manufacturing on the Valve e) Non-Returnable Valve f) CE Approved Valve g) RATING 4A, 89B The Fire Extinguisher Shall be Helium Leak Detection tested to 10-7 mb l/s Make Supremex, Ceasefire, Minimax
Supply and fixing of ISI marked (IS:15683) Fire Extinguisher seamless construction, Carbon-di-oxide type capacity 4.5 Kg.flat base including valve, discharge hose of not less than 10 mm dia., 1M long and complete in all respects incuding initial fill with CO² gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and with wall suspension bracket. Make Supremex, Ceasefire, Minimax
Water Mist Fire Extinguisher Trolley Mounted (Design : Low Pressure) 50L Capacity Model Supremex WM-TR-02, With One Compressed Air Cylinder 6 Ltr. X 300 bar (Stainless Steel), 10 Nos. O Rings, One Can 5 Ltr. AFFF Compound, One Tool Kit. Fire Ratings :- 55A, II B(233B X 2) Make Supremex, Ceasefire, Minimax
Supply and fixing of air cushion tank (Air vessel) 200mm dia & 1500mm height having 8mm thick dished ends made of 8mm thick MS pipe and Supply 25mm dia with brass air release valve, safety valve, pressure gauge suitable MS support and minor civil works etc as required.
Supply and fixing of structural steel including 8mm thick MS plate, ISMC, ISA, M14, 110 LONG Anchor Fastners, with one coat of RED LEAD primer and two coat of Black paint complete all as specified and directed.
Supply , erection, commisioning and testing of C.I. Butterfly valves of 100mm sizes with Body: IS:210 , PN-16, confirming to IS:13095 complete all as specified and directed.
Supply , erection, commisioning and testing of CI non-return valves Gun Metal internals 100 mm dia, Rubber seated shall be conforming to IS:5312. PN 16 rating with matching Flanges , Nut, bolts, washer & Gaskets complete all as specified and directed. 100 mm dia
Supply , erection, commisioning and testing of Forge Brass Ball valves 25 mm diawith screwed ends lever operated , conforming to IS standard complete all as specified and directed
Supply, installation, testing and commissioning of Electric Terrace fire control panel metal clad cubical type suitable for 415 V AC three phase 4 wire 50Hz supply system.The panel should be suitable for automatic operation for the fire pump as per the specifie parameter. The panel shall be copletely compartmentalised and complete with relays, contractors, starters, Aluminium bus bar, designation lables as per requirement, Contineous earth bar, panel separators, protective screens, cable clamping supports system, panel lamps, top/bottom cable gland plate for incoming and outgoing cable enteries complete all as specified and directed .
S&F cable XLPE insulated screened PVC bedded, GI strip or wire armoured, Electric power cable heavy duty 1100 V grade of following sizes
(a) 6 core x 2.5 sq mm multi strand copper un armoured
(b) 150 sq mm x 3.5 core aluminium armoured
(c) 25 sq mm x 3.5 core aluminium armoured
Supply, erection, commisioning and testing of Pressure gauges with controlling cocks etc shall be of approved make having pressure range, bourdon material and 100mm min dial size with isolation valves on discharge pipe of each pump complete all as specified and directed .
Supply , erection, commisioning and testing of Pressure switches with accessories shall be of approved make and design and shall actuate (`cut-off' and/or `make contact' as required) at pre-set pressures with isolation valve complete all as specified and directed .
Supply , erection, commisioning and testing of C.I. 2 Way Fire Brigade Connection of 150 mm dia with Gun metal coupling complete Four instantaneous with NRV and 6 inch inlet flange with matching flanges, gaskets, stud bolts etc complete in all respects.
Providing, fixing, testing and commishioning of heavy class GI pipe, IS: 1239 marked with all necessary fittings tees elbows, flanges, reducers gaskets, nuts and bolts etc. welded or screwed joints as required including fixinf the pipe with necessary structural supports (Location: paint room) of the following size
(i) 150 mm dia (Nominal Bore)
Providing, fixing, testing and commishioning of heavy class MS pipe, IS 3589 marked with all necessary fittings like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc, welded or screwed joints as required including fixing the pipe with necessary structural supports (for deliver/suction main fold relating to the pumps) including painting of two coats of synthetic enamel paint over a coat of red oxide primer including all cuttings and making good the same (location: plant room) of the following size
200mm dia nominal bore (6.32 mm thick) with necessary supports etc as required.
Providing fixing testting and commissioning of 150mm dia 6.35 thick flanged and basket 300 mm height of Y0type stainer made from MH body with bottom and top removable flanges with nuts and bolts etc. Having filteration area atleast 6 times the cross sectinoal area of the pipe.
Providing fixing testing and commissioning of C.I butterfuly valve (PN 1.6 ratings) confirming to IS:13095 with flages, nuts and bolts and washers complete for following sizes
150mm dia (Nominal Bore)
Providing fixing testing and commissioning of dual plat non-return valve complete with nuts and bolts and washers complete for following sizes.
150mm dia (Nominal Bore)
Supply , erection, testing and commisioning of fire brigade draw of connection confirming to IS :4038-1986 with 15mm non return valve / stainer including necessary fitting the word fire FIRE BRIGADE DRAW OFF to be painted on the box complete all as specified and directed.
M&L for EGRESS EDGE Lit light with costomizable print and colour with back up of 2-3 hours on battery, brand (LIFE GUARD HOCHIKI< AGNI< PROLITE) double sided complete all as specified and directed.
M&L for EGRESS EDGE Lit light with costomizable print and colour with back up of 2-3 hours on battery, Brand (LIFE GUARD, HOCHIKI, AGNI, PROLITE) singlele sided 300x125mm complete all as specified and directed.
Note :- Complete schedule pertaining to FIRE FIGHTING AND DETECTION shall be executed by a firm dealing with such services.
AIR CONDITIONING
EQUIPMENT
Water Cooled Chilling Machines
Supply installing, testing and commissioning. of 50TR water cooled Scroll Chilling Machines fitted with hermetically sealed compressors, multi circuit Dx chiller,water cooled S&T condenser, Microprocessor based control panel,suitable for R-407 C Refrigerant, Shell & Tube Insulated Evaporator,Expansion Device, Suitable capacity Control Mechanism actual Cooling capacity on following Operation Parametres. Complete as per specifications and drawings. (Make : VOLTAS / BLUE STAR / CARRIER Chilled Water Entering Temperature : 12.17 deg C Chilled Water Leaving Temperature : 6.67 deg C Evaporator Fouling Factor : 0.0001 MKS Condenser Water Entering/Leaving Temperature at 36.2/32.4 deg C Refrigerant : R-407 C Maximum Allowable IKW / TR @ 100% Load : 1.55 Scope of Supply (a) 1set.- Scroll compressor hermetic complete with suaitble capacity squirell cage induction motor with class 'F' insulation suitable for operation on 415+ 10% volts, 50Hz, A.C. supply and automatic capacity control, safety switches, forced feed lubrication system etc. as per specifications. (b) 1No. Close transition type automatic star-delta starter suitable for compressor motor complete with ammeter with CTs, over load protection, under voltage protection, protection against phase reversal & independent single phase preventors etc. complete as required. (c) 1 Set - Lubrication device consisting of automatic electric oil pump, oil cooler, oil strainer,automatic pressure regulating valve, oil heater, oil heater thermal switch etc. as per specifications.
(d) 1 Set. - Matching Water Cooled condenser having Copper tube with Mechanically bonded aluminium fins. (e) 1No. - Matching DX type chiller for Chiller units (f) 1 Lot- Refrigerant piping fittings, valves and accessories to interconnect compressor, condenser, chiller and expansion valve. (g) 1 Set- Microprocessor based control panel complete with all safeties, controls and LCD display as per specifications. (h) Lot- Refrigerant line accessories comprising of safety valves, angle valve, liquid line indications. (j) Lot- Water flow switches at inlet and outlet of chiller. Water drain and air purge valves whenever required. (k) Lot- Suction line and chiller insulation with minimum 19mm thick polyvinyl nitril rubber insulation complete as required. (l) Lot- Frame work for mounting the above condenser, chiller compressor and motor with base plate complete with anti vibration pads/springs. (m) Lot- Initial / first charge of refrigerant gas and compressor oil. (n) 1 No. Chilled water flow Switch of suitable size and capacity (o) Lot-PCC cement concrete foundation for the Chiller unit (2 W + 1 S) Note : Next higher capacity of chiller can be supplied within overall cost quoted
Chilled Water Pump Set
Supply installing, testing and commissioning. of centrifugal mono block type chilled water pump set capable of delivering min. 300 USGPM of water against 30 mtr head each comprising of the following and complete as per specifications and drawings. (a) 1 No.- mono block type pump (b) 1 No. - Suitable HP TEFC squirell cage induction motor with class 'F' insulation 2900 rpm synchronous speed, operating on 415+ 10% volts, 3 phase, 50 Hz A.C. supply. (c) Lot- insulation of pump of 13 mm thick with aluminium foil faced closed cell chemically crossed linked XPE foam material. (d) 2 Nos. -100 mm dia dial type pressure gauges. (e) Lot- Mounting frame with Anti vibration pads. (f) Lot-PCC cement concrete foundation for the pump unit (1 working simultaneously & 1 working standby---Each of 100% cap)
Condenser Water Pump Set
Supply installing, testing and commissioning of centrifugal mono block Condender water pump set capable of delivering min. 400 USGPM of water against 22.00 mtr head each comprising of the following and complete as per specifications and drawings. (a) 1 No.- mono block type pump (b) 1 No. - Suitable HP TEFC squirell cage induction motor with class 'F' insulation 2900 rpm synchronous speed, operating on 415+ 10% volts, 3 phase, 50 Hz A.C. supply. (c) 2 Nos. -100 mm dia dial type pressure gauges. (d) Lot- Mounting frame with Anti vibration pads. (e) Lot-PCC cement concrete foundation for the pump unit (1 working simultaneously & 1 standby---Each of 100% cap)
Hot Water Pump Set
Supply installing, testing and commissioning of centrifugal mono block type chilled water pump set capable of delivering min. 120 USGPM of water against 30 mtr head each comprising of the following and complete as per specifications and drawings. (a) 1 No.- mono block type pump (b) 1 No. - Suitable HP TEFC squirell cage induction motor with class 'F' insulation 2900 rpm synchronous speed, operating on 415+ 10% volts, 3 phase, 50 Hz A.C. supply. (c) Lot- insulation of pump of 13 mm thick with aluminium foil faced closed cell chemically crossed linked XPE foam material. (d) 2 Nos. -100 mm dia dial type pressure gauges. (e) Lot- Mounting frame with Anti vibration pads. (f) Lot-PCC cement concrete foundation for the pump unit (1 working simultaneously & 1 working standby---Each of 100% cap)
AIR HANDLING UNITS
Supply installing, testing and commissioning of double skin floor mounted type air handling unitswith Thermal Break Profile suitable for Outdoor Installation,fabricated & assembled complete, made of 48 mm thick panels consisting of GI casing of thickness 0.8 mm outside layer and 0.8 mm inside layer, injected at factory by moulding machine with polyurethane foam (PUF) insulation complete with blower section and filter section with filter of 10 micron at 90% efficiency, chilled water coil constructed out of copper tubes not less than 0.5mm thickness and aluminum fins, Suitable capacity TEFC drive squirrel cage induction motor 415 ± 10% volts, centrifugal forward / backward curved fan suitable for 50 mm SP, access door and mixing box with VCD for supply air, return air and fresh air, complete as per std. specification. Maximum face velocity across the coil shall be 500 FPM and each 6 Row deep Ch. water cooling coil and 2 Row deep hot water coil, and RH to be maintained at 55 %± 10 of following capacities and comprising of :-(a) Coil of copper tube and aluminium construction sized at maximum face velocity of 500 FPM.(b) Pre filter of 10 micron at 90% efficiency on the face of the coil in return air stream(c).Squirrel cage induction motors suitable for 415 ± 10% volts, 50 Hz, AC supply meeting criterion as per ASHRAE standard 90.1-2007 and high efficiency.(d) Fan belt drive package(e) Vibration isolators. (e) Fan outlet velocity not exceeding 10 mps. Tag No. Space CFM AHU No. 1 to 3 AS shown in Drg 15000 F.M
Electric Hot Water Generator
(a) Supply installing, testing and commissioning of Electric Hot Water Generator of 120 KW for winter & Monsoon Reheating complete with control wiring as per specification and drawings.
(b) Supply installing, testing and commissioning of Pan type Humidifier of cap. 6 KW complete with SS sheet tank duly insulated and complete with control wiring as per specification and drawings.
COOLING TOWER
Supply, Installation, testing and commissioning of FRP cooling tower of minimum 120 TR heat rejection capacity with FRP water basin PVC fillings with integral louvers and drift eliminators complete with hot water basin either fitted with spray nozzles or having self rotating sprinklers, statically & dynamically balanced axial flow type fan direct driven or driven through reduction gear box with TEFC induction motor , suction screen, make up quick filling arrangement, over flow and drain connections with necessary valves and suitable inspection ladder, access arrangement for cooling lower interior, installed on MS girders (MS-I sections) fixed in masonry foundations with cement concrete footing, second class brick work and cement mortor1:6; all accessories, basin fittings, fan, fan motor suitable for 415 Volt supporting structure, anti vibration mountings etc. complete and 50 HZ power supply having isolator panel with MCB at cooling tower and with following technical data. (a) Water flow/tower 480 USGPM (b) Ent. Water Temp. 97 °F (c) Basin water Temp. 90 ˚F
MOTOR CONTROL PANEL FOR AC PLANT
MOTOR CONTROL PANEL FOR AHUs .
ELECTRICAL CABLES
S& F in ground/ in ducts/in pipes/on cable trays of following PVC insulated aluminum/copper conductor armoured cables of 1.1 KV grade confirming to IS complete with cable tray, clamps, saddles etc, including effecting proper connection to the equipment all as required and specified:-
(a) 3.5 C x 95 Sq.mm (aluminum) for Chillers & Hot Water Generator.
(b) 3.5 C x 35 Sq.mm (aluminum) for main to AHU Panels.
(c) 3C x 6 Sq.mm (copper) for Chilled Water , Condenser pumps, Hot water Pump, CT Fan & AHU Blowers motors
(d) 4C x 1.5 Sq.mm (copper) For Controls
Notes:- (i) The cost includes cost of suitable pipes for cable protection at road crossings, cable trays, protective bricks, sand and excavation. (ii) All exposed cables in trenches/wall/ceiling/roof trusses shall be provided with silicon based fire resistance coating compatible for PVC cables. (iii) All terminations shall be made with proper lugs in the approved manner
EARTHING
S & F GI earth strip 25 mm x 4 mm below ground, in 40 mm GI pipe wherever required and on surface or in recess for connections etc.
Supply, fixing, installation and commissioning of earthing complete with galvanised steel earth plate 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip of size 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel connected to earthing test point including charcoal dust and commom salt; necessary excavation in soft loose soil, returning, filling in and removal of surplus soil upto a distance of 50 m; PCC pit in cement concrete 1:3:6 type C1 using 20 mm grade stone aggregate; precast 40 mm thick pit cover cast in RCC 1:2:4 type B-1 (using 20 mm grade stone aggregate) reinforced with 8 mm dia. TMT bar, 75 mm c/c both ways, MS handle12 mm dia., PGI funnel, wire mesh and GI watering pipe of 20 mm bore (light grade) and earth lead protection pipe of 40 mm pipe (light grade) including earthwork complete; all as specified and directed by the engineer-in-charge including testing on completion.
Note:- (i) All terminations shall be made with proper lugs in the approved manner
PIPING-CHILLED WATER & HOT WATER SYSTEM
Supply install testing & comissioning of the following nominal sizes of chilled water and hot water plumbing pipes MS ‘C’ CLASS as per IS: 1239, with necessary clamps, vibration isolators and fitting like flanges, union etc. but excluding valves, strainers, gauges etc.) cut to required lengths and welded at joints and inclusive of accessories like elbows, tees, reducers, sockets etc. including insulating with 19 mm (for all pipes) and 13mm (for drain pipe) thick closed cell chemically cross linked fire retardant polyethylene foam insulation of density 30 Kg/cum. The thermal conductivity of the material should not exceed 0.035 W/Mk at an average temp of 40 deg C,covered with aluminium sheet cladding 24 gauge complete with application with rubber based adhesive Pidilite SR 998 y, all as specified and repairing damage to building etc.and conforming to the specified specification:
(a) 125 mm dia
(b) 100 mm dia
(c) 80 mm dia
(d) 65 mm dia
(e) 50 mm dia
Supply, installation, testing and commissioning of following types of valves, strainers, gauges in chilled water plumbing and adequately supported as per specifications:-
(i) Supplying and fixing in position the following butterfly valves
(a) 100 mm dia Valves
(b) 80 mm dia Valves
(c) 65 mm dia Valves
(d) 50 mm dia Valves
(ii) Supplying and fixing in position the following manual balancing valves:
(a)100 mm dia Valves
(b) 80 mm dia Valves
(c) 50 mm dia Valves
(iii) Supplying and fixing in position the following ‘Check Valves :
(a) 80 mm dia Valves.
(b) 65 mm dia Valves.
(c) 50 mm dia Valves.
(iv) Supplying the following Gate Valves
(a) 32 mm dia without insulation
(v) Supplying, installation, testing and commissioning of Auto air vents. 15 mm dia
(vi) Supply,installation,testing and commissioning of 25 mm dia Ball valves for drain with fittings etc.
(vii) Supplying and fixing in position the industrial type pressure gauges
(viii) Supplying and fixing in position the mercury-in- glass industrial type thermometers complete with fitttings.
(ix) Supplying and fixing in position the water flow switches as per drawings and specifications for the Chilled water circuit complete with fitttings
(x) Supply,installation,testing and commissioning of 3 way mixing valve for fixing in chilled water piping in the AHU complete for the Air Handling Units complete with required controls wiring/installation kit etc. As per drawings and specifications.
(xi) Supply,installation,testing and commissioning of proportional cooling only thermostats for the Air Handling Units complete with required controls wiring/installation kit etc. As per drawings and specifications.
(xii) Supply, fixing, testing and commissioning of condenser water pipes of MS class ‘C’ of following sizes and material along with necessary clamps, vibration isolators and fittings such as bends, tees etc but excluding strainer and gauges etc adequately supported on rigid supports/buried in ground as per specifications and as required
(a) 125 mm dia
(b) 100 mm dia
(xiii) Supplying and fixing in position the following ‘Y' type strainer :
(a) 100 mm dia .
(b) 80 mm dia .
(c) 65 mm dia .
Supplying and fixing in position the following GI class ‘B’ pipes cut to required lengths and installed with all screwed joints, and Supplying and fixing in position the necessary elbows, tees and reducers as per specifications.
(a) 32 mm dia GI pipes
Expansion Tank
Supply,installation,testing and commissioning of HDPE expansion tank of size 1000 Lt complete with suitable with FR- XLPE/XPE 19 mm thick of minimum bulk density 28±4Kg/cum covered with vapour barrier and finished with 0.5 mm thick AI cladding and applied with Pidilite SR 998complete with air vent and drain connection with float valve, quick fill and control valves and suitable foundation etc. as required.
Make Up Tank
Supply,installation,testing and commissioning of HDPE make up tank of size 5000 Ltr. complete with air vent and drain connection & overflow, make up connection with float valve & foundation etc. complete. .
AIR DISTRIBUTION
Supply, installation and testing of GI sheet metal ducts for supply air & return air system as per IS - 655 in accordance with the approved shop drawings and as required by the specifications.
(a) 24 gauge galvanised sheet steel
(b) 22 gauge galvanised sheet steel
(c) 20 gauge galvanised sheet steel
Supply, fabrication, installation and testing the flexible connections constructed of fire resistant double resin sleeve as per the approved shop drawings.
Grilles/ Diffusers.
Supplying, fixing, testing and commissioning of powder coated aluminium section of 20 G thick forsupply/ return air grilles / diffusers without aluminium volume control dampers as per specifications.
Volume Control Damper
Supplying, fixing, testing and commissioning of GI volume control dampers made of 20 G thick sheet as per specifications.
Fresh Air Grilles
Supplying, fixing, testing and commissioning of powder coated extruded aluminium section of 20 G thick for fresh air grill in weather maker room with volume control dampers, bird screen etc complete as required.
Supply, installation, testing and commissioning of motorised combined fire damper made of 20 G GI sheet complete with control panel, inter connecting wiring as specified and directed.
(a) Fire Dampers
(b) Actuators
(c) Control Panel & Wiring
THERMAL INSULATION
Supply install test and commissioning of acoustic insulation of duct as shown on drawing with 25 mm resin bonded fibre glass, of 48 kg/cum density, covered with and 28 G Aluminium perforated sheet all as specified.
Supply install test and commissioning of thermal insulation of duct with 13 mm thick closed cell chemically cross linked fire retardant polyethylene foam insulation of density 30 Kg/cum. The thermal conductivity of the material should not exceed 0.035 W/Mk at an average temp of 40 deg C,covered with aluminium faced foil complete with application with rubber based adhesive Pidilite SR 998 and 50mm x 3 mm thick self adhesive tape on both longitudinal & transverse joints simultaneously all as specified.
Supply install test and commissioning of acoustic insulation of walls of the AHU Rooms as shown on drawing with 50 mm thick resin bonded fibre glass, of 32 kg/cum density, fixed in GI frame work of 600 x 600 mm made of 24 gauge GI sheet and covered with tissue paper and 26 G Aluminium perforated sheet all as specified.
Supply and fix air curtain suitable for 2 mtr wide and 2.5 hiegt doors complete with blower fan with motor suitable for 230 volts single phase 50 Hz AC supply complete of make : Ravi Aircon / Beacon.
Note :- (a) Any minor modification required for sucessful operation of plant are deemed to be included in overall rates quoted. (b) Complete plant shall be run for a period of four months or till completion of first PHASE TWO TEST whichever is later within overall cost quoted by contractor
AUDITORIUM CHAIRS
S&F Auditorium chairs, Make Model Godrej Model No FU23411X069SXXXX,/ Make Methodex Model No. AUDITORIUM 02, / Make Wipro Model No Symphony.
Balwan Builders (BID ID -3162024)
M/S Mukesh Kumar Gupta (BID ID -3162812)
M/S Shiv Shakti Enterprises (BID ID -3162502)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .