Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAdmitted-Fee/PreQual/Technical/Finance | L1 | Admitted-Fee/PreQual/Technical/Finance | |
| 2 | L2₹8.2 L+₹67,297 (8.90%)Admitted-Fee/PreQual/Technical/Finance NADUVILPAT HOUSE KALLARAMANGALAM PO VIJAY ENGINEERING KADAMPUZHA MALAPPURAM PIN 676553 | MALAPPURAM | KERALA | 676553 | L2 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | P. R. RIJESH L1 | RAJESH R L2 |
|---|---|---|---|---|---|
| 1.00Electrification | |||||
| 1.00 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C | 76 | point | 1,400 ₹1,06,400 Lowest | 1,500 ₹1,14,000 |
| 1.00 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm | 268.3 | metre | 100 ₹26,830 Lowest | 100 ₹26,830 Lowest |
| 1.00 | 1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm | 80 | metre | 190 ₹15,200 Lowest | 190 ₹15,200 Lowest |
| 1.00 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm | 120 | metre | 140 ₹16,800 Lowest | 145 ₹17,400 |
| 1.00 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm | 110 | metre | 210 ₹23,100 Lowest | 217 ₹23,870 |
| 1.01 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | 27 | each | 330 ₹8,910 Lowest | 389 ₹10,503 |
| 1.01 | 90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. | 27 | each | 150 ₹4,050 Lowest | 179 ₹4,833 |
| 1.01 | 1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) | 8 | each | 280 ₹2,240 Lowest | 315 ₹2,520 |
| 1.01 | 1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). | 16 | each | 430 ₹6,880 Lowest | 504 ₹8,064 |
Tender Value
₹8.3 L
EMD Value
₹20,741
Closing Date
22 Jun 2026, 4:00 pmClosed
ASSISTANT ENGINEER
PONNANI MUNICIPALITY
Annual Plan-PONNANI MUNICIPALITY-AYURVEDHA HOSPITAL Electrification
2025_LSGD_798658_72
PNI/03/2025-I
Open Tender
Electrical Works
Item Rate
30 days
PONNANI MUNICIPALITY
Please refer Tender documents.
11 documents required · 11 mandatory
₹1,830
Yes
₹20,741
Yes
30 Jun 2026
16 Jun 2026
23 Jun 2026
16 Jun 2026
22 Jun 2026
16 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Electrification | |||||
| 1.001 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C | - | point | - | - |
| 1.002 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm | - | metre | - | - |
| 1.003 | 1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm | - | metre | - | - |
| 1.004 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm | - | metre | - | - |
| 1.005 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm | - | metre | - | - |
| 1.006 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | - | each | - | - |
| 1.007 | 90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. | - | each | - | - |
| 1.008 | 1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) | - | each | - | - |
| 1.009 | 1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). | - | each | - | - |
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.25 MB
Tendernotice_2.pdf
PDF • 0.30 MB
Tendernotice_3.pdf
PDF • 0.21 MB
Tendernotice_4.pdf
PDF • 0.25 MB
Tendernotice_5.pdf
PDF • 0.25 MB
Tendernotice_6.pdf
PDF • 0.10 MB
Tendernotice_7.pdf
PDF • 0.96 MB
Tendernotice_8.pdf
PDF • 0.10 MB
ab.pdf
Tender Documents • 0.11 MB
BOQ_1446599.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .