TH E CONSTRUCTION OF BIRTH & DEATH AND OTH ER DEPT OFFIC ES AT SARDAR MA RKET VADODARA MUNICIPAL CORPORATION
278782
PRO No.1184/25-26, Building Project
Open
Miscellaneous Works
Works
Vadodara
5 documents required · 5 mandatory
₹20,000
Municipal commissioner ,Vadodara municipal corporation
₹62.3 L
20 Feb 2026
20 Feb 2026
20 Feb 2026
7 Mar 2026
20 Feb 2026
Excavation for foundation including sorting out and
1 9069.00 stacking the excavated stuff up to 50mt lead for A) Cmt 120.01
Loose or soft soil
Upto 1.50 mt. depth
2 9024.00 1.50 mt.to 3.0 mt depth Cmt 133.07
Filling available excavated Earth (Excluding Rock) in
trench plinth side of foundation etc. in layer not
exceeding 20 cm in depth consolidation each deposited
layer by ramming and watering etc. complete.
Providing and laying rubble for appron (each stone
5 2116.10 weighting not less than 40Kg.) including and packing Cmt 1067.08
and filing in the interstices with quarry-spalls.
Disposal of Surplus excavated Earth and/or debris etc.
6 8879.40 including all lifts, for 400 - 500 m lead outside of Cmt 129.28
campus etc. complete.
Disposal of Surplus excavated Earth and/or debris etc.
7 13319.10 including all lifts, for 5 to 10 km lead outside of L.S 237.87
campus etc. complete.
Filling in foundation and plinth with murrum or selected
soil in layers of 20cm. thickness including watering,
ramming and consolidating etc. complete. (more than
Carring out plinth treatment to post construction /
existing structure by spraying chemical solution for
termite control treatment including labour and material
consistment with I.S.I specification. Using Chlordene
and Chiorpurfiles 20 EC. As Per 6131_paret-II
Consentration Weight one percent is recommended i.e
one litre 20 EC chemical emulsion with 19 liter give 1 %
concrentration inclusive of one litre chemical emulsion
appication at the rate of 5 Litre chemical / Sqm of
surface is recommended as per I.S
Clearing and grubbing road land including uprooting
rank vegetation grass bushes, shrubs, sapling and trees
10 0.31 girth up to 300 mm removal of stumps of trees cut Hectare 28455.09
earlier and disposal of unserviceable materials (C) By
mechanical means in area of light jungle
CEMENT CONCRETE
Providing and laying cement concrete 1:4:8 (1- Cement :
11 523.37 4- coarse sand : 8- hand broken stone aggregates 40 mm Cum 2747.21
nominal size) and curing complete excluding cost of
formwork in (A) Foundation and Plinth (upto 10 ton)
Providing and laying controlled cement concrete M.250
and curing complete excluding the cost of formwork and
12 3433.08 reinforcement for reinforced concrete work in (A) Cum 4247.57
Foundations, footings, Base of columns and Mass
concrete. (more than 10 ton)
Providing and laying controlled cement concrete M.250
and curing complete excluding the cost of formwork and
13 1001.63 reinforcement for reinforced concrete work in (B) Walls, Cum 4551.51
from top of foundation level upto floor two level (upto
Item Accoring to
but may be Item Work Unit Tender Rates
Providing and laying in position Ready Mixed M-250
grade concrete for reinforced cement conctere work
using cement content as per approved Design Mix
manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead up
to 10 kms having continuous agitated mixer,
manufactured as per mix design of specified grade for
reinforced cement concrete work including pumping of
R.M.C. from transit mixer to site of laying, excluding
the cost of centering shuttering finishing and
reinforcement including cost of admixtures in
recommended proportions as per IS: 9103 to accelerate/
retard setting of concrete, improve workability without
impairing strength and durability as per direction of the
Engineer - in - charge. Without Fly Ash (Min cement
level as per latest IS 456 shall be maintained) (Cement
BASEMENT & GF SLAB + BEAM
15 247.70 FF SLAB + BEAM Cum 4896.32
16 247.70 SF SLAB + BEAM Cum 4896.32
17 195.70 TF SLAB + BEAM Cum 4896.32
18 195.70 FOURTH FLOOR SLAB + BEAM Cum 4896.32
19 195.70 FIFTH FLOOR SLAB + BEAM Cum 4896.32
20 175.70 Sixth FLOOR SLAB + BEAM Cum 4896.32
21 29.04 TERRACE PARAPET WALL Cum 4896.32
22 35.06 CABIN SLAB+BEAM Cum 4896.32
Providing and laying in position Ready Mixed M-300
grade concrete for reinforced cement conctere work
using cement content as per approved Design Mix
manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead up
to 10 kms having continuous agitated mixer,
manufactured as per mix design of specified grade for
reinforced cement concrete work including pumping of
23 22.69 R.M.C. from transit mixer to site of laying, excluding Cum 5093.12
the cost of centering shuttering finishing and
reinforcement including cost of admixtures in
recommended proportions as per IS: 9103 to accelerate/
retard setting of concrete, improve workability without
impairing strength and durability as per direction of the
Engineer - in - charge. Without Fly Ash (Min cement
level as per latest IS 456 shall be maintained) (Cement
level 475 kg) OVER HEAD WATER TANK
Providing and laying controlled cement concrete M.200
and curing complete excluding the cost of formwork and
24 151.84 reinforcement for reinforced concrete work in (E) Cum 5453.20
Staircases excluding landing upto floor two level (more
Providing and laying cement concrete work 1:2:4 (1-
Cement : 2- Coarse sand : 4- graded stone aggregates
mm nominal size) and curing complete excluding cost of
25 14.35 formwork and reinforcement for reinforced concrete Cum 4023.57
work in (B) shelves, Balconis , Lintels, Girders and
Cantilever upto floor two level. (more than 10 ton)
R.C.C. AT SILL LEVEL
Item Accoring to
but may be Item Work Unit Tender Rates
26 14.35 1st Floor Cum 4023.57
27 10.76 2nd Floor Cum 4023.57
28 10.76 3rd Floor Cum 4023.57
29 10.76 4th floor Cum 4023.57
30 10.76 5th Floor Cum 4023.57
31 12.76 6th Floor Cum 4023.57
Providing and laying controlled cement concrete M.250
and curing complete excluding the cost of formwork and
reinforcement for reinforced concrete work in (D)
Columns, Pillars posts and struts, upto floor two level.
(more than 10 ton)
36 141.56 4th floor Cum 4628.14
37 141.56 5th Floor Cum 4628.14
38 105.05 6th Floor Cum 4628.14
39 4.32 STAIR CABIN + LIFT ROOM Cum 4628.14
Providing TMT Bar FE 500D reinforcement for R.C.C.
work including bending, binding and placing in position
complete upto floor two level
Providing formwork of ordinary timber planking so as to
give a rough finish including centering, shuttering and
propping etc. height of propping and centering below
supporting floor to ceiling not exceeding 4.00 mts and
removal of the same for in situ reinforced cement
concrete works.
A) Foundation and plinth
(B) Flat surfaces such as soffits of supspened floors
42 11608.62 slabs Landings and the like. (1) Floors etc. upto 200 mm Sqm 260.88
in thickness. (more than 10 ton)
(C) Vertical surface such as walls (any thickness)
(G) Columns PillarsPosts and struts. (1) Square
Rectangular Polygonal in plan. (upto 10 ton)
(H) (1) Sides and soffits of Beams Beam Haunchings
45 4195.72 cantilevers Girders Bressumers and Lintels not Sqm 202.18
exceeding 1 M. in Depth. (upto 10 ton)
(M) Staircase with sloping or stepped soffits including
risers and stringers excluding landing. (upto 10 ton)
(I) Edges of slabs and Breaks in floors and walls. (upto
Brick work using common burnt clay building bricks
having crushing strength not less than 35 kg./Sq.Cm. in
foundation and plinth in Cement Mortar 1:6 (1- Cement
: 6 -fine sand)(A) Modular (upto 10 ton)
In foundation and plinth
49 308.61 GROUND FLOOR. Cmt 4498.19
50 308.61 1st FLOOR. Cmt 4498.19
Item Accoring to
but may be Item Work Unit Tender Rates
51 308.61 2nd FLOOR. Cmt 4542.35
52 308.61 3rd FLOOR. Cmt 4586.52
53 258.61 4th FLOOR Cmt 4630.69
54 258.61 5th FLOOR Cmt 4674.86
55 258.61 6th FLOOR Cmt 4719.02
56 42.11 Terrace level Cmt 4763.19
(ii) Half brick masonry in common brunt clay building
bricks having crushing strength not less than
Kg/Sq.Cm. in Cement mortar 1:5 (1- Cement : 5 -coarse
sand ) in foundation and plinth (A) Modular (upto
58 214.20 1st FLOOR. Smt. 595.67
59 214.20 2nd FLOOR. Smt. 645.21
60 214.20 3rd FLOOR. Smt. 694.75
61 189.20 4th Floor Smt. 744.29
62 189.20 5th Floor Smt. 793.83
63 189.20 6th Floor Smt. 843.37
PLASTER & PAINTING
Providing 15mm thick cement plaster in single coat on
Rough (Similar)side of single or half brick walls for
interior plastering upto floor two level and finished even
and smooth in (i) Cement mortar 1:4 (1-cement:3-sand)
GROUND FLOOR. & basement
65 2607.66 1st FLOOR. Smt. 171.21
66 2607.66 2nd FLOOR. Smt. 195.18
67 2607.66 3rd FLOOR. Smt. 219.16
68 2307.66 4th Floor Smt. 243.14
69 2307.66 5th Floor Smt. 267.11
70 2607.66 6th Floor Smt. 291.09
71 447.07 T.C. AND PERAPET+ LIFT ROOM Smt. 315.07
Providing 10mm thick cement plaster in single coat on
Rough (Similar)side CEILINGs for interior plastering
72 4370.27 upto floor two level and finished even and smooth in (i) Smt. 196.64
Cement mortar 1:3 (1-cement:3-sand)
GROUND FLOOR. & basement
73 1440.27 1st FLOOR. Smt. 196.64
74 1440.27 2nd FLOOR. Smt. 220.61
75 1440.27 3rd FLOOR. Smt. 244.59
76 1440.27 4th Floor Smt. 268.57
77 1440.27 5th Floor Smt. 292.55
78 1440.27 6th Floor Smt. 316.52
79 256.49 T.C. AND PERAPET+ LIFT ROOM Smt. 340.50
20mm thick sand faced cement plaster on walls upto
height 10 metres above ground level consisting of 12mm
80 11867.46 thick backing coat of C.M. 1:3 (1-cement : 3-sand) and Smt. 337.52
8mm thick finishing coat of C.M. 1:1 (1-cement : 1-
sand) etc. complete.
Provoding and fixing Before plaster work Chicken wire
81 2560.00 mesh 16 x24 OR Fiber Chicken mesh (1meter width x Smt. 184.02
50 meter length waterproofing crack patch work and etc
82 32427.67 Applying two coats of Birla or Asian (or equivalent) Smt 40.59
acrylic lapy ( putty) & two coats of primer of approved
Item Accoring to
but may be Item Work Unit Tender Rates
brand and manufacture on new wall surface to give an
even shade including thoroughly brushing the surface
free from mortar dropping and other foreign matter and
sand papered smooth.
Wall painting (two coats) with plastic emulsion paint of
approved brand and manufacture on undecorated wall
surface to give an even shade including throughly
83 32427.67 brushing the surface free from mortar droppings and smt 80.87
other foreign matter and sand papered smooth. + Extra
over for every subsequent coat of wall painting with
plastic emulsion pain of approved brand.
Finishing Wall with weather proof exterior plastic
emulsion paint on wall surface (two coats) to give an
84 11867.46 required shape even shade after thoroughly brushing SMT 117.40
surface to remove all dirt and remains of loose powdered
materials etc comp. for all height.
Painting two coats (excluding priming coat) on new steel
and other metal surface with enamel paint, brushing,
85 1284.48 interior to give an even shade including cleaning the Smt 90.00
surface an even shade including cleanicn the surface of
all dirt, dust and other foreign matter.
P & L 24" x 24" vitrified 8 mm thick tile flooring over
20 mm (average) base of cement mortar 1:6 ( 1 cement:
6 coarse sand) on new surface or fixing on existing
flooring by adhesive material including dismentaling of
existing flooring and jointed with color cement slurry
including finised with flush pointing & cleaning the
surface etc. complete for light shade (upto 10 ton)
Providing and laying Vitrified tiles 8 to 10 mm thick , in
skrting risers of steps and dedo on 10mm thick cement
plaster 1:3 (1-cement : 3-coarse sand) and jointed with
white cement slurry
Providing and laying polished granite stone slab 12 to
mm thick in thread,risers of steps,skirting,,lift wall
cladding etc Dedo and pillars laid on 10mm thick
88 1892.32 cement mortar 1:3 (1-Cement : 3 coarse sand) and Smt 1956.17
jointed with gray cement slury mixed with including
rubbing and edge polishing and moulding etc.
complete. (upto 10 ton)
Providing and laying cement concrete 1:3:6 (1- Cement :
3- Coarse sand : 6- Graded brick bat aggregate 40mm
89 207.52 normal size) and curing complete excluding cost of Cum 3060.65
formwork in slopes terrace for area for water proofing
work as directed by EIC.
Providing and laying broken chine mosaic flooring for
terrace using 12 mm to 20 mm broken pieces of glazed
tiles to be laid over cement mortar 1:3 to plain or slope
and to be tempered to bring mortar creme out upto
surface using white cement including rounding off
junctions and extending them upto 15 cm along the
wall,clearing with water and oxalic acid and including
using water proofing material at the rate of 1 Kg./bag of
cement. etc. for water proofing work as directed by
Item Accoring to
but may be Item Work Unit Tender Rates
Preparing and applying of water soluble, nonflammable,
reactive and penetrative silane nanotechnology with
water (<1000 ppm TDS) in the ratio of 1 liter silane :20
liter water mixed with 0.5 liter acrylic copolymer
polymer compatible and stable in silane solution. Take
liter of silane nanotechnology and add in 20 liter water
in drum under manual stirring and then add 0.5 liter
acrylic copolymer under manual stirring and mix
completely. Spray apply the solution at the rate of 1 liter
per sqm on horizontal and 0.5 liter per sqm on vertical
new or old cementitious / concrete surface . (For very
dense concrete of M50 and above for bridges may not
absorb 1 liter per sq meter so reduce the water of
dilution to 1:10)Horizonal Surface
Providing cement vata (10cm. x 10 cm. size) quarter
92 960.20 round in cement mortar 1:1 including neat cement Smt 24.28
finishing, watering etc. complete.
P/F 25 mm. Thick Polished Granite kotah stone
sandwitch type platform 0.75 width & 0.70 m height
resting on single/ double polished kotah stone of 25 mm
93 88.20 thick in C.M. 1:4 with Granite stone of 25 mm thick SMT 3680.51
with cupboard shelves polished kotah stone etc. comp.
As per Architect instructions and drawing or as
directed by engineer in charge..
Providing and laying marble stone slab flooring over
20mm (average)base of cement mortar 1:6 (1-cement :
94 56.70 coarse sand) laid and jointed with gray cement slurry SMT 2191.42
including rubbing and polishing complete. (A) Marble
slab 25mm thick (upto 10 ton)
Providing and fixing Kitchen sink with C.I. or M.S.
brackets, painted white including cutting holes in walls
and making good the same but excluding fittings. (C)
Stainless steel Sink.(i) 600mm x 450mm x 150mm size
(NIRALI, HINDWARE etc..) INCL. all fittings and
fixtures etc. all complete as directed by EIC.
Provoding and fixing flush door shutters, solid core
construction with frame of first class hardwood with
cross board and face veneer or plywood face panels,
including anodised alluminium butt hinges with
necessary screws. (B) Non-decorative type and block
board core anodised alluminium butt hinges in flush
door shutters (2) 35 mm thick.
97 882.00 Laminated sheet 1.00 mm thick SQM 299.58
Providing and fixing 35 mm thick shutters for Doors,
windows and clear story windows including anodised
98 33.26 alluminium butt CUDM 4039.91
hinges with necessary screws.(A) Indian Teak Wood (1)
Providing and fixing window having extruded aluminum
Colour anodized section frame main outer size 127mm x
38.10mm 1.35mm @wt. 1.384kg/m, horizontal Four
track member size 122.20mm x 31.75mm x 1.10mm@
wt 1.20 kg/m, vertical member of size 122.20mm x
31.75mm x1.50mm @1.398 kg/mt with sliding shutters
Item Accoring to
but may be Item Work Unit Tender Rates
of horizontal member size 40mm x 18mm x 1.29mm@
0.456kg/mt ,vertical member of size 40mm x 18mm x
1.29mm @ 0.456 kg/mt with 5 mm thick transparent
bronze colour tinted float glass with powder coated
aluminum fittings and fixtures and transparent silicon
sealant glass fixing to frame as per details etc complete
Providing and fixing M.S. grills of required pattern to
wooden frames of windows etc. with M.S. flats at
100 17714.80 required spacings and frame alround, square or round KG 105.18
bars with round headed bolts and nuts or by screws (A)
Plain Grill. (upto 10 ton)
101 3500.00 Black Japan Paint used for retaining wall back side. lit 43.65
102 632.00 PVC Rubber Water Stopper 150width 15mm thick RMT 80.80
Providing and fixing PVC printed false ceiling with
flush type with alluminium frame, frame work is done
with three different sections of G.I. sheet of 24 gauge
thickness named as C, U and L. The C section is fixed
with hangers at an equal distance of 36” each and then U
section is fixed perpendicular on C section with steel
screws at and equal distance of 16” each. The complete
frame work is supported by G.I. L angle/6 mm rod
hangers from the roof and L sections is fixed all around
the wall as shown in the diagram. 5mm PVC sheet strips
of size 2 wide are fixd with counter sunk steel screws on
the U section. Further 3mm PVC sheet is stuck to these
PVC strips with solvent cement such that joining lines
are perfectly matched. P.U. putty is filled, dried and
leveled and requisite coats of primer and paint is done
on the ceiling for getting fine surface finish etc.
complete as per direction of
Engineering and charge manufacturer’s specification
104 136.00 S.S. Railing pipe 50 mm x 16 G ASIS 304 Grade rmt 1014.28
105 43.20 S.S. Rialing Sq pipe 32x32 mm x 16G ASIS 304 Grade rmt 458.78
106 416.00 S.S. Railing pipe 16 mm x 16G ASIS 304 Grade rmt 369.76
Providing and laying tactile tile (for vision impaired
persons as per standards) of size 300x300x9.8 mm
having with water absorption less than 0.5% and
conforming to IS:15622 of approved make in all colours
and shades in for outdoor floors such as footpath, court
yard, multi modals location etc., laid on 20 mm thick
base of cement mortar 1:4 (1 cement : 4 coarse sand) in
all shapes & patterns including grouting the joints with
white cement mixed with matching pigments etc.
complete as per direction of Engineer-in-Charge.
Excavation for foundation upto 1.5 m depth including
sorting out and stacking of useful materials and
disposing off the excavated stuff upto 50 Meter lead.(A)
Loose or soft soil. 0 To 1.5 mt. Depth
Excavation for foundation for depth from 1.5 m to 3.0 m
including sorting out and stacking of useful materials
and disposing off the excavated stuff upto 50 Meter
lead.(A) Loose or soft soi. (ii) 1.5 to 3.0 mt depth
Item Accoring to
but may be Item Work Unit Tender Rates
Providing and laying cement concrete 1:4:8 (1- Cement :
4-Coarse sand : 8- Graded Brick bats aggregate 40mm
normal size) and curing complete excluding cost of
formwork in (A) Foundation and Plinth
Providing and fixing wsh down water closet (European
type, W.C. Pan) with integral P or Strap including
jointing the trap with soil pipe in Cement Mortar 1:1 (1-
Cement : 1-fine sand) (Seal and cover to be measured
and paid for separately)(A) vitreous China Pattern :(i) in
Providing and fixing chromium plated brass half trun
112 90.00 flush cock of approved quality including fixing in pipe Each 263.77
line etc. complete.(ii) 25mm dia.
Providing and fixing plastic seat and cover for wash
113 90.00 down water closer with C.P. brass hinges and rubber Each 291.33
buffers. (B) Black plastic seal and cover.
Providing and fixing Urinal of approved quality
including connection with trap and with integral
longitudinal flush pipe.(A) Squating plate pattern white
earthenware 550mm x 300mm.
Providing and fixing washbasin with single hole for
pillar tap with C.I. or M.S. brackets painted white
including sutting holes and
making good the same but excluding fittings.(A)
Vitreous China:(ii) Flat Back washbasin 550 mm x v
400mm size. (i) In white colour.
Providing and fixing C.P. brass waste for washbasin or
Providing and fixing C.P. brass waste for washbasin or
117 16.00 sink. Each 89.83
Providing and fixing 600mm x 450mm bevelled edge
mirrror of superior glass mounted on 6mm thick A.C.
118 60.00 sheet or plywood Each 854.58
sheet and fixing to wooden pluge with C.P. brass screws
Providing and fixing C.P. brass towel rail comlete with
C.P. brass brackets fixed to wooden plugs with C.P.
brass scews.(B)
600mm x 20mm size.
120 90.00 'Providing and fixing toilet paper holder. (A) C.P. Brass Each 427.99
Providing and fixing PVC SWR Nahni trap IS 14735 for
drain - 100 mm diameter with jali of the following
121 158.00 nominal diameter of self cleansing design with C.I Each 585.37
scread down or hinged grating including the cost of
cutting and making good the walls.
Providing and fixing to wall ceiling and floor 10.0 Kg.
F/Cm2 working pressure poluthene pipes of the
following outside Dia. Low densidy, complete with
special falnge compression type fittings, wall clipsetc.
including making good the wall ceiling and floor.
Item Accoring to
but may be Item Work Unit Tender Rates
Providing and laying (to level or slopes) and jointing
with stiff mixture of Cement Mortar in proportion 1:1
Salt glazed stoneware pipes including testing of pipes
and joints complete.(B) 150mm dia.
Providing and fixing S.W. gully trap with C.I. grating
brick masonry chamber and water tight C.I. cover with
125 20.00 frame of 300mm x 300mm size (inside) with standard Each 1246.92
weight.(i) Square mouth traps.(B) 150mm x 100mm size
Constructing brick masonry chamber for underground
C.I. Inspection chamber and bends with bricks having
crushing strength not less than 35Kg/Cm2 in C.M. 1:5
C.I. cover with frame (Light duty) 455mm x 610mm
intenal dimensions total weight of cover with frame to
be not less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of
126 10.00 frame 15Kg. ) (R.C.C. top slabe with 1:2:4 mix (1- Each 3660.76
cement :2- coarse sand :4-graded stone aggregate 20mm
size) foundation concrete 1:5:10 inside plaster 15mm
thick with cement mortar 1:3 finished smooth with a
floating coat of neat cement on walls and bed concrete
etc. complete.(ii) Inside dimensions 500mm x 700 mm
and 450mm deep for pipe line with one or two inlets.
Constructing brick masonry chamber for underground
C.I. Inspection chamber and bends with bricks having
crushing strength not less than 35Kg/ Cm2 in C.M. 1:5
C.I. cover with frame (Light duty) 455mm x 610mm
intenal dimensions total weight of cover with frame to
be not less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of
127 2.00 frame 15Kg. ) (R.C.C. top slabe with 1:2:4 mix (1- Each 7180.44
cement :2- coarse sand :4-graded stone aggregate 20mm
size) foundation concrete 1:5:10 inside plaster 15mm
thick with cement mortar 1:3 finished smooth with a
floating coat of neat cement on walls and bed concrete
etc. complete.(iii) Inside dimensions 600mm x 850 mm
and 450mm deep for pipe lines with three or more inlets.
Constructing Manhole with R.C.C. top slab in 1:2:4 mix
(1-cement :2-coarse sand : 4-graded stone aggregate
20mm nominal size) foundation concrete 1:3:6 mix (1-
cement : 3- coarse sand :6-Brick bats 40 + 50mm size)
inside plastering 15mm thick with Cement Mortar 1:5
(1-Cement : 5-coarse sand) finished with a floating coat
of neat cement and making channels in cement concrete
1:2:4 mix (1-Cement :2-Coarse sand :4-stone aggregate
20mm nominal size) finished smooth complete including
128 2.00 curing and festing (i) Inside size 900mm x 1200mm and Each 11042.74
1.5M. deep including C.I. cover with frame size 560mm
diameter total weight of cover and frame to be not less
than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame
(A) With 230mm thick walls of brick msonry using
brick having crushing strength not less than 35Kg. /
Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse
sand) (1) A type depth 0.90 Metre for 150mm
129 Chapter No. = 24 0.00
Item Accoring to
but may be Item Work Unit Tender Rates
Constructing Manhole with R.C.C. top slab in 1:2:4 mix
(1-cement :2-coarse sand : 4-graded stone aggregate
20mm nominal size) foundation concrete 1:3:6 mix (1-
cement : 3- coarse sand :6-Brick bats 40 + 50mm size)
inside plastering 15mm thick with Cement Mortar 1:5
(1-Cement : 5-coarse sand) finished with a floating coat
of neat cement and making channels in cement concrete
1:2:4 mix (1-Cement :2-Coarse sand :4-stone aggregate
20mm nominal size) finished smooth complete including
130 2.00 curing and festing (i) Inside size 900mm x 1200mm and Each 19349.63
1.5M. deep including C.I. cover with frame size 560mm
diameter total weight of cover and frame to be not less
than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame
(A) With 230mm thick walls of brick msonry using
brick having crushing strength not less than 35Kg. /
Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse
sand) (2) B type depth 1.50 Metre for 150mm
diameter sewer.
Constructing Manhole with R.C.C. top slab in 1:2:4 mix
(1- cement :2 coarse sand : 4-graded stone aggregate
20mm nominal size) foundation concrete 1:3:6 mix (1-
cement : 3- coarse sand :6-Brick bats 40 + 50mm size)
inside plastering 15mm thick with Cement Mortar 1:5
(1-Cement : 5-coarse sand) finished with a floating coat
of neat cement and making channels in cement concrete
1:2:4 mix (1-Cement :2- Coarse sand :4 stone aggregate
20mm nominal size) finished smooth complete including
curing and festing (i) Inside size 900mm x 1200mm and
1.5M. deep including C.I. cover with frame size 560mm
diameter total weight of cover and frame to be not less
than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame
Kg.)(A) With 230mm thick walls of brick msonry using
brick having crushing strength not less than 35Kg. /
Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse
sand) (3) C type depth 2.25 Metre for 150mm diameter
Providing and fixing cast iron steps of size 500mm x
132 30.00 150mm x 22.5mm and painting with two coats of Anti- Each 207.66
corrosive paint etc. complete.
Providing laying and jointing in true line and level
U.P.V.C. Pipe ( SCH- 40) for cold water including
fittings as approved by Engineer In Charge. Pipe shall be
fixed on the wall with the help of clamp at every two
133 650.00 metre C/C or shall be concealed as directed including Rmt 72.65
necessary fittings etc. including testing of pipe and joints
and fixing the same with adhesive solvent, including
cost of all materials.
Providing and fixing ball cock of approved. quality as
directed.(A) Copper Metal (i) 25mm dia.
Item Accoring to
but may be Item Work Unit Tender Rates
Providing and fixing ball cock of approved. quality as
directed.(A) Copper Metal (ii) 50mm dia.
Providing and fixing Gun metal check or non-return
fullway wheel valve.(C) 25mm dia.
Providing and fixing Gun metal check or non-return
fullway wheel valve.(E) 40mm dia.
Providing and fixing Gun metal wheel valve of
142 5.00 following diameter Each 160.05
Providing and fixing screw down bib taps of following
size.(B) Brass chromium plated screws down Bib Tap.
Providing and fixing pillar tap, capstan head, screw
downhigh pressure with screws, shanks and back nuts.
148 156.00 Providing and fixing Rubber plug for sink or wash basin. Each 17.15
Providing and fixing chromium plated, bottle trap with
necessary couplings of approved quality for wash basin.
Providing and fixing brass screw down stop tap. (A)
Providing, laying and jointing in true line and level
diametre U.P.V.C (Type B) conforming to IS 13592-
1992 with one end plain and other end socketed with
rubber ring, & fittings conforming to ISI 14735-1999 of
approved make for drainage system pipe line, pipe shall
be jointed with each other with rubber lubricant, pipe
151 110.00 shall be fixed on wall using of PVC clamp of the size R.M 834.38
160 mm diametre x 210 mm length x 196 mm heigh at
every 2000 mm center to center or shall be concealed in
walls as directed including necessary fittings such as
bends, shoes etc. including testing of pipes and joints
and jointed with adhesive solvent cement including cost
of all materials.
Providing and fixing in position cowel went to pipes.(C)
Providing and fixing in position cowel went to pipes.(B)
Providing erecting and fixing double coated ISI water
tank of required capacity each with all necessary fittings
and connection etc.complete on terrace (For security-1
Providing erecting and fixing double coated ISI water
tank of required capacity each with all necessary fittings
and connection etc.complete on terrace (For security-2
Providing erecting and fixing double coated ISI water
tank of required capacity each with all necessary fittings
and connection etc.complete on terrace (For ground
Item Accoring to
but may be Item Work Unit Tender Rates
Providing erecting and fixing double coated ISI water
tank of required capacity each with all necessary fittings
and connection etc.complete on terrace (For drinking
water storage, for 1000 persons per day)
Providing laying (to level or slopes) and jointing
reinforced concrete Light duty non-pressure pipes I.S.
158 160.00 class NP2 of the following internal diameter with collars Rmt 254.89
and butt ends prepared for collar joints including testing
of joints complete.(B) 150mm
Providing laying (to level or slopes) and jointing
reinforced concrete Light duty non-pressure pipes I.S.
159 0.00 class NP2 of the following internal diameter with collars Rmt 356.73
and butt ends prepared for collar joints including testing
of joints complete.(C) 250mm
Providing & Laying (To level or slopes) & jointing
reinforced concrete light duty non pressure pipes IS
160 230.00 class NP3 of the following internal diameter with collars Rmt 882.74
and butt ends prepared for collar joints including testing
of joints complete. RCC300 dia pipe 0.7kg/Sq.cm
Constructing Brick masonry road gully chamber 450mm
x 450mm x 775mm with vertical gating complete.
Excavation for foundation including sorting out and
162 44.50 stacking the excavated stuff up to 50mt lead for A) CMT 120.01
Loose or soft soil
Upto 1.50 mt. depth
Boring holes 3.5 m deep in ordinary soil (for cast in situ
piles) and getting out the soil and disposal of the surplus
excavated soil as directed within a lead of 50 Meter for
following diameter of pipes.(iii) 300 medial mensicus
Proving Borewell witch all accessories isi approved
materials bore 6 inch and as per site condition water
164 2.00 level required depth All materials bore wich Nos 111100.00
submersible pum set use as per tender details our
engineer in charge
Providing and laying cement concrete 1:4:8 (1- Cement :
4- coarse sand : 8- hand broken stone aggregates 40 mm
nominal size) and curing complete excluding cost of
formwork in (A) Foundation and Plinth (upto 10 ton)
Providing and laying controlled cement concrete M.250
and curing complete excluding the cost of formwork and
166 63.15 reinforcement for reinforced concrete work in (A) CMT 4247.57
Foundations, footings, Base of columns and Mass
concrete. (more than 10 ton)
Providing TMT Bar FE 500D reinforcement for R.C.C.
167 4047.84 work including bending, binding and placing in position KG 77.29
complete upto floor two level (more than 10 ton)
Providing formwork of ordinary timber planking so as to
give a rough finish including centering shuttering
strutting and propping etc. Height of propping and
centering below supporting floor to ceiling not
exceeding 4 M. and removal of the same for in situ
reinforced concrete and plain concrete work in. (A)
Foundations Footings Bases of Columns etc. and Mass
Item Accoring to
but may be Item Work Unit Tender Rates
(G) Columns PillarsPosts and struts. (1) Square
Rectangular Polygonal in plan. (upto 10 ton)
(H) (1) Sides and soffits of Beams Beam Haunchings
170 48.92 cantilevers Girders Bressumers and Lintels not SMT 202.18
exceeding 1 M. in Depth. (upto 10 ton)
Brick work using common burnt clay building bricks
having crushing strength not less than 35 kg./Sq.Cm. in
foundation and plinth in Cement Mortar 1:6 (1- Cement
: 6 -fine sand)(A) Modular
20mm thick sand faced cement plaster on walls upto
height 10 metres above ground level consisting of 12mm
172 1100.59 thick backing coat of C.M. 1:3 (1-cement : 3-sand) and SMT 337.52
8mm thick finishing coat of C.M. 1:1 (1-cement : 1-
sand) etc. complete.
Finishing wall with weather proof exterior emulsion
paint on wall surface (two coats) to give an required
173 1100.59 shape even shade after thoroughly brushing the surface SMT 117.40
to remove all dirt, and remains of loose powdered
materials.etc complete
Structural steel work ( Confirming to IS 4923-1997)
riveted,bolted or welded in builtup for all type sections,
in framed work, including cutting, hoisting, fixing in
174 732.00 position and applying a priming coat of approved steel KG 131.15
complete as per the structural designs and directions of
Engineer in charge.Column ( 122 x 61 x 3.6mm )
Painting two coats (excluding priming coat) on new steel
and other metal surface with enamel paint, brushing,
175 58.56 interior to give an even shade including cleaning the SMT 90.00
surface an even shade including cleanicn the surface of
all dirt, dust and other foreign matter.
176 20.00 Barbed wire for fencing of galvanized steel wire Quintal 5820.34
R.C.C. ROAD AND PAVING
Box cutting the road surface to proper slope and camber
177 434.27 for making a base for road work including removing the Cum 104.20
excavated stuff and depositing on the road side slope as
directed upto 50Mt.lead.
Earthwork for embankment including breaking clods,
dressing with all lead and lift (excluding watering and
consolidation)(E) From Borrow area within 3.0 Km.
lead (more than 10 ton)
Rolling of earthwork in layers with power roller
179 171.24 including filling in depressions which occur during the Cum 13.40
process. (more than 10 ton)
180 171.24 Watering of earth work as directed. Cum 9.08
Providing and laying cement concrete 1:4:8 (1- Cement :
4- coarse sand : 8- hand broken stone aggregates 40 mm
nominal size) and curing complete excluding cost of
formwork in (A) Foundation and Plinth (upto 10 ton)
Providing and laying in position Ready Mixed M-250
grade concrete for reinforced cement conctere work
182 169.67 using cement content as per approved Design Mix Cum 4776.90
manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead up
Item Accoring to
but may be Item Work Unit Tender Rates
to 10 kms having continuous agitated mixer,
manufactured as per mix design of specified grade for
reinforced cement concrete work including pumping of
R.M.C. from transit mixer to site of laying, excluding
the cost of centering shuttering finishing and
reinforcement including cost of admixtures in
recommended proportions as per IS: 9103 to accelerate/
retard setting of concrete, improve workability without
impairing strength and durability as per direction of the
Engineer - in - charge. Without Fly Ash (Min cement
level as per latest IS 456 shall be maintained) (Cement
Providing TMT Bar FE 500D reinforcement for R.C.C.
183 5090.02 work including bending, binding and placing in position Kg 77.18
complete upto floor two level
Finishing of C.C.Road by provinding labour charges by
using vaccum dewatering pump floater surface vibrator
including making grooves Rufe finish to surface
levelling up etc. comp As Per engineer in charge.
Excavation for foundation including sorting out and
stacking the excavated stuff up to 50mt lead for A)
Loose or soft soil
Upto 1.50 mt. depth
Providing and laying cement concrete 1:4:8 (1- Cement :
4- coarse sand : 8- hand broken stone aggregates 40 mm
nominal size) and curing complete excluding cost of
formwork in (A) Foundation and Plinth (upto 10 ton)
Providing and fixing pre-cast Rubber Dye / steel Dye
inter locking concrete block 60mm thick with grade of
concrete M300 pnumatic compressed / vibrated
mechanically and as per approved design Confirming to
IS 15658 : 2006 including 35 mm Sand layer for
levelling and filling the joint with sand in proper line
and level as per guidlines of IRC : SP 63-2018 etc.
Providing and fixing pre-cast concrete kerb stone of gray
cement based concrete block 30cm length,30cm height
and 15cm thick of M250 grade concret as per approved
design and including excavation for fixing in proper line
and level,filling the joint with C:M 1:3 (1cement:3fine
sand) etc complete.
Providing and supplying evenly priming / tack coat with
bitumen @ rate of 10 Kg/ Sq.M. (including heating the
but excluding the cost of bitumen
Trenching in ordinary soil up to a depth of 30-60 cm
including removal and stacking of serviceable materials
and then disposing of surplus soil, by spreading and
neatly levelling within a lead of 50 m and making up the
trenched area to proper levels by filling with earth or
earth mixed with sludge or / and manure before and after
flooding trench with water (excluding cost of imported
earth, sludge or manure).(CPWD 2020 Item No . 2.1)
Supplying and stacking of good earth at site including
royalty and carriage upto 5 km lead complete (earth
Item Accoring to
but may be Item Work Unit Tender Rates
measured in stacks will be reduced by 20% for
payment). (CPWD 2020 Item No . 2.2)
Providing & laying Selection no. 1 doob grass turf with
earth 50mm to 60mm thickness of existing ground
prepared with proper level and rammingwith required
tools wooden and than rolling the surface with light
rollermake the surface smoothen and light watering the
same maintenance for 45 days or more till the
grassestablish properly,as per direction of officerin
charge (Code 2.34 CPWD 2020) item no.
Complete maintenance of the entire garden features
having as per yard stick in the garden area i.e. lawn
trees, shrubs, edge, flower beds, foliages, creepers,
plants etc. including hoeing,weeding pruning
replacement of plants, gap filling, watering, mowing of
lawn, grass cutting by lawn mover and brush cutter,
removal of garden waste, applying insecticide, pesticide
& fertilizers (whenever required) top dressing of lawn
193 1285.52 with good earth and menure and maintenance of other 2.73
garden related works as directed by office-in-charge
(Cost of Good Earth, Manure, Fertilizer, Insecticide,
Pesticide, lawn mover and brush cutter with fuel & other
T & P material/ articles shall be provided by the
department.) 2.39.5 Play grounds / Public parks Per
(1Mali for 2.00Acre). (CPWD-2020, Horti &
Landscaping, It No-5.9, Pgno-93)
GENERAL FURNITURE WORKS
Providing & Fixing of SOFA as per Detail
Drawings/Architects specifications. The SOFA (Two
Seat) made out From MR Grade 303 Plywood
(Century/Green/Wigwam/CPL make) with Bottom Side
fixnig of 19mm Thick Plywood for Base and Above
Fixing of 19mm Thick Plywood with Vertical Side
fixing of 19mm Thick Plywood with BackSide fixing of
06mm Thick Plywood nad Fixing of 06mm Thick
Flexible Plywood with Inside Fixing of
Wooden/Aluminium/GI/ Framming with Fixing of
Foam, and fixing of Approved Shade Fabric (Sharom or
Equ. make) with Required Side Fixing of nut, Bolt,
Achor Fastner, SS Leg, Wooden Leg, Wooden Handle,
with Required Hardware, Material like Nail (surya
Make), Screw (Hettich/Hepo make), Adhesive (Fevicol
Make), Tools, Tackles & labour Etc Work Complete as
per Detail Drawings. P/F of TWO SEAT SOFA
Providing & Fixing of RECEPTION TABLE as per
Detail Drawings/Architects specifications. The
RECEPTION TABLE made out From MR Grade
Plywood (Century/Green/Wigwam/CPL/Derby Make)
with Top Side Fixing of 19mm Thik Plywood, Vertical
Side fixing of 19/16mm Thick Plywood, Bottom side
Fixing of 19/12mm Thick Plywood with and Required
Back Side Fixing of 06mm Thick Plywood with Inside
Fixing of 0.8mm Thick Off White Laminate
(Timex/CPL make) with outer Surface Fixing of 1mm
Item Accoring to
but may be Item Work Unit Tender Rates
Thick Approved Shade Laminate Vertical/Horzontal
Grains with Chamfer
(Timex/AICA/CPL/Century/Green/Dolby Make) with
Edge Side Fixing of 22/19/32/42mm Thick Edge Band
(Rehau make) with Top Side Fixing of 06mm Thick
White colour Solid Surface with Sealent with Solid
surface`s Chemical (No Gap/Joint Between Joints) with
Buffing work with Fitting of Required hardware,
Material like Nail (surya Make), Screw (Hettich/Hepo
make), Adhesive (Fevicol Make), T/C
(Hafele/Hepo/Hettich/Ebco make), Hinge
(Hafele/Hepo/Hettich/Ebco make) Tools, Tackles &
labour Etc Work Complete as per Detail Drawings.
Providing & Fixing of SIDE STORAGE as per Detail
Drawings/Architects specifications.
The STORAGE made out From MR Grade 303 Plywood
(Century/Green/Wigwam/CPL/Derby Make) with Top
Side Fixing of 19mm Thik Plywood, Vertical Side
fixing of 19/16mm Thick Plywood, Bottom side Fixing
of 19/12mm Thick Plywood with and Required Back
Side Fixing of 06mm Thick Plywood with Inside Fixing
of 0.8mm Thick Off White Laminate (Timex/CPL
make) with outer Surface Fixing of 1mm Thick
Approved Shade Laminate Vertical/Horzontal Grains
196 82.35 with Chamfer (Timex/AICA/CPL/Century/Green/Dolby Sqm 25755.00
Make) with Edge Side Fixing of 22/19/32/42mm Thick
Edge Band (Rehau make) with Top Side without Fixing
of STONE. The STORAGE Will having Openable
Shutter at Equal distance or Architect`s Specifications
with Top Side fixing of TWO DRAWERS with Fitting
of Required hardware, Material like Nail (surya Make),
Screw (Hettich/Hepo make), Adhesive (Fevicol Make),
T/C (Hafele/Hepo/Hettich/Ebco make), Hinge
(Hafele/Hepo/Hettich/Ebco make), 4" Handle (SS
Finish) Tools, Tackles & labour Etc Work Complete as
per Detail Drawings.
Providing & Fixing of BACK STORAGE made out
From MR Grade 303 Plywood
(Century/Green/Wigwam/CPL/Derby Make) with Top
Side Fixing of 19mm Thik Plywood, Vertical Side
fixing of 19/16mm Thick Plywood, Bottom side Fixing
of 19/12mm Thick Plywood with and Required Back
Side Fixing of 06mm Thick Plywood with Inside Fixing
of 0.8mm Thick Off White Laminate (Timex/CPL
make) with outer Surface Fixing of 1mm Thick
197 86.45 Approved Shade Laminate Vertical/Horzontal Grains Sqm 25755.00
with Chamfer (Timex/AICA/CPL/Century/Green/Dolby
Make) with Edge Side Fixing of 22/19/32/42mm Thick
Edge Band (Rehau make) with Top Side without Fixing
of STONE. The STORAGE Will having Openable
Shutter at Equal distance or Architect`s Specifications
without Top Side fixing of TWO DRAWERS with
Fitting of Required hardware, Material like Nail (surya
Make), Screw (Hettich/Hepo make), Adhesive (Fevicol
Make), T/C (Hafele/Hepo/Hettich/Ebco make), Hinge
Item Accoring to
but may be Item Work Unit Tender Rates
(Hafele/Hepo/Hettich/Ebco make), 4" Handle (SS
Finish) Tools, Tackles & labour Etc Work Complete as
per Detail Drawings.
Providing & Fixing of OVERHEAD STORAGE made
out From MR Grade 303 Plywood
(Century/Green/Wigwam/CPL/Derby Make) with Top
Side Fixing of 19mm Thik Plywood, Vertical Side
fixing of 19/16mm Thick Plywood, Bottom side Fixing
of 19/12mm Thick Plywood with and Required Back
Side Fixing of 06mm Thick Plywood with Inside Fixing
of 0.8mm Thick Off White Laminate (Timex/CPL
make) with outer Surface Fixing of 1mm Thick
Approved Shade Laminate Vertical/Horzontal Grains
with Chamfer (Timex/AICA/CPL/Century/Green/Dolby
Make) with Edge Side Fixing of 22/19/32/42mm Thick
Edge Band (Rehau make) with Top Side without Fixing
of STONE. The STORAGE Will having Openable
Shutter at Equal distance or Architect`s Specifications
without Top Side fixing of TWO DRAWERS with
Fitting of Required hardware, Material like Nail (surya
Make), Screw (Hettich/Hepo make), Adhesive (Fevicol
Make), T/C (Hafele/Hepo/Hettich/Ebco make), Hinge
(Hafele/Hepo/Hettich/Ebco make), 4" Handle (SS
Finish) Tools, Tackles & labour Etc Work Complete as
per Detail Drawings.
Providing and fixing CNC cut panelling work of size -
Size: L 5210mm x H 2952mm
Providing & Fixing of MAIN TABLE with
PADESTAL as per Detail Drawings/Architects
specifications.
The MAIN TABLE made out From MR Grade
Plywood (Century/Green/Wigwam/CPL/Derby Make)
with Top Side Fixing of 25mm Thik Plywood, Vertical
Side fixing of 19/16mm Thick Plywood, Bottom side
Fixing of 19/12mm Thick Plywood with and Required
Back Side Fixing of 06mm Thick Plywood with Inside
Fixing of 0.8mm Thick Off White Laminate
(Timex/CPL make) with outer Surface Fixing of 1mm
Thick Approved Shade Laminate Vertical/Horzontal
200 7.00 Grains with Chamfer (Timex/ AICA/ CPL/ Nos 50500.00
Century/Green/Dolby Make) with Edge Side Fixing of
22/19/32/42mm Thick Edge Band (Rehau make). 6mm
Corian on table top as per architect's specification. The
PADESTAL`s Will Having 3 Numbers Drawers Lock
with 3 in 1 Lock with Fitting of Required hardware,
Material like Nail (surya Make), Screw (Hettich/Hepo
make), Adhesive (Fevicol Make), T/C
(Hafele/Hepo/Hettich/Ebco make), Hinge
(Hafele/Hepo/Hettich/Ebco make), 3 in 1 Lock, 4" SS D
Handle Tools, Tackles & labour Etc Work Complete as
per Detail Drawings.
Size 2100 X 1000 X
Providing & Fixing of MAIN TABLE with
201 18.00 PADESTAL as per Detail Drawings/Architects Nos 38885.00
specifications.
Item Accoring to
but may be Item Work Unit Tender Rates
The MAIN TABLE made out From MR Grade
Plywood (Century/Green/Wigwam/CPL/Derby Make)
with Top Side Fixing of 25mm Thik Plywood, Vertical
Side fixing of 19/16mm Thick Plywood, Bottom side
Fixing of 19/12mm Thick Plywood with and Required
Back Side Fixing of 06mm Thick Plywood with Inside
Fixing of 0.8mm Thick Off White Laminate
(Timex/CPL make) with outer Surface Fixing of 1mm
Thick Approved Shade Laminate Vertical/Horzontal
Grains with Chamfer (Timex/ AICA/CPL/ Century/
Green/ Dolby Make) with Edge Side Fixing of
22/19/32/42mm Thick Edge Band (Rehau make). 6mm
Corian on table top as per architect's specification. The
PADESTAL`s Will Having 3 Numbers Drawers Lock
with 3 in 1 Lock with Fitting of Required hardware,
Material like Nail (surya Make), Screw (Hettich/Hepo
make), Adhesive (Fevicol Make), T/C
(Hafele/Hepo/Hettich/Ebco make), Hinge
(Hafele/Hepo/Hettich/Ebco make), 3 in 1 Lock, 4" SS D
Handle Tools, Tackles & labour Etc Work Complete as
per Detail Drawings. Size 2100 X 750 X
Providing & Fixing of MAIN TABLE with
PADESTAL as per Detail Drawings/Architects
specifications.
The MAIN TABLE made out From MR Grade
Plywood (Century/Green/Wigwam/CPL/Derby Make)
with Top Side Fixing of 25mm Thik Plywood, Vertical
Side fixing of 19/16mm Thick Plywood, Bottom side
Fixing of 19/12mm Thick Plywood with and Required
Back Side Fixing of 06mm Thick Plywood with Inside
Fixing of 0.8mm Thick Off White Laminate
(Timex/CPL make) with outer Surface Fixing of 1mm
Thick Approved Shade Laminate Vertical/Horzontal
202 32.00 Grains with Chamfer (Timex/ AICA/ CPL/ Century/ Nos 34845.00
Green/Dolby Make) with Edge Side Fixing of
22/19/32/42mm Thick Edge Band (Rehau make). 6mm
Corian on table top as per architect's specification. The
PADESTAL`s Will Having 3 Numbers Drawers Lock
with 3 in 1 Lock with Fitting of Required hardware,
Material like Nail (surya Make), Screw (Hettich/Hepo
make), Adhesive (Fevicol Make), T/C
(Hafele/Hepo/Hettich/Ebco make), Hinge
(Hafele/Hepo/Hettich/Ebco make), 3 in 1 Lock, 4" SS D
Handle Tools, Tackles & labour Etc Work Complete as
per Detail Drawings.
Size 1800 X 600 X
Providing & Fixing of MAIN TABLE with
PADESTAL as per Detail Drawings/Architects
specifications.
The MAIN TABLE made out From MR Grade
203 310.00 Plywood (Century/Green/Wigwam/CPL/Derby Make) Nos 31108.00
with Top Side Fixing of 25mm Thik Plywood, Vertical
Side fixing of 19/16mm Thick Plywood, Bottom side
Fixing of 19/12mm Thick Plywood with and Required
Back Side Fixing of 06mm Thick Plywood with Inside
Item Accoring to
but may be Item Work Unit Tender Rates
Fixing of 0.8mm Thick Off White Laminate
(Timex/CPL make) with outer Surface Fixing of 1mm
Thick Approved Shade Laminate Vertical/Horzontal
Grains with Chamfer (Timex/ AICA/ CPL/ Century/
Green/ Dolby Make) with Edge Side Fixing of
22/19/32/42mm Thick Edge Band (Rehau make). 6mm
Corian on table top as per architect's specification. The
PADESTAL`s Will Having 3 Numbers Drawers Lock
with 3 in 1 Lock with Fitting of Required hardware,
Material like Nail (surya Make), Screw (Hettich/Hepo
make), Adhesive (Fevicol Make), T/C
(Hafele/Hepo/Hettich/Ebco make), Hinge
(Hafele/Hepo/Hettich/Ebco make), 3 in 1 Lock, 4" SS D
Handle Tools, Tackles & labour Etc Work Complete as
per Detail Drawings. Size 1200 X 600 X
Providing & Fixing of PANTRY BOTTOM
STORAGE as per Detail Drawings/Architects
specifications.
The STORAGE made out From BWP 710 Grade
Plywood (Century/Green/Wigwam/CPL/Derby Make)
with Top Side Fixing of 19mm Thik Plywood, Vertical
Side fixing of 19/16mm (Calibrated) Thick Plywood,
Bottom side Fixing of 19/12mm Thick Plywood with
and Required Back Side Fixing of 06mm Thick Plywood
with Inside Fixing of 0.8mm Thick Off White Laminate
(Timex/CPL make) with outer Surface Fixing of 1mm
Thick Approved Shade Laminate Vertical/Horzontal
204 24.00 Grains with Chamfer (Timex/ AICA/ CPL/ Century/ Sqm 38885.00
Green/ Dolby Make) with Edge Side Fixing of
22/19/32/42mm Thick Edge Band (Rehau make) with
Top Side Fixing of STONE. The STORAGE Will
having Openable Shutter at Equal distance or Architect`s
Specifications with Fitting of SS BASKET, Cup Soucer,
Thali, Thali Plain, Pullout with Fixing of Required
hardware, Material like Nail (surya Make), Screw
(Hettich/ Hepo make), Adhesive (Fevicol Make), T/C
(Hafele/ Hepo/ Hettich/ Ebco make), Hinge (Hafele/
Hepo/ Hettich /Ebco make), 4" Handle (SS 304 Finish)
Tools, Tackles & labour Etc Work Complete as per
Detail Drawings.- Size: L 2020mm x H 750mm
Providing & Fixing of LOW HT WOODEN
PARTITION as per Detail Drawings/ Architects
specifications.
The LOW HT WOODEN PARTITION made out From
MR 303 Grade Plywood
(Century/Green/Wigwam/CPL/Derby Make) with Both
Side Fixing of 12mm Thik Plywood and Required inside
205 18.50 Wooden/Aluminium hollow Pipe Framing (Aluminium Sqm 9039.50
2" x 1" x 1.2mm T) with outer Surface (Both Side of
Partition) Fixing of 1mm Thick Approved Shade
Laminate Vertical/Horzontal Grains with Chamfer
(Timex/AICA/CPL/Century/Green/Dolby Make) with
CP Teakwood Frame with Applying of Polish on
Wooden patti with Fitting of Required hardware,
Material like Nail (surya Make), Screw (Hettich/Hepo
Item Accoring to
but may be Item Work Unit Tender Rates
make), Adhesive (Fevicol Make), Tools, Tackles &
labour Etc Work Complete as per Detail Drawings.
Providing & Fixing of MEETING TABLE as per Detail
Drawings/ Architects specifications. The MEETING
TABLE made out From MR 303 Grade Plywood
(Century/Green/Wigwam/CPL/Derby Make) with Top
Side Fixing of 19mm Thik Plywood, Vertical Side
fixing of 19/16mm Thick Plywood, Bottom side Fixing
of 19/12mm Thick Plywood with and Required Back
Side Fixing of 06mm Thick Plywood with Inside Fixing
of 0.8mm Thick Off White Laminate (Timex/CPL
make) with outer Surface Fixing of 1mm Thick
Approved Shade Laminate Vertical/Horzontal Grains
with Chamfer (Timex/AICA/CPL/Century/Green/Dolby
Make) with Edge Side Fixing of 22/19/32/42mm Thick
Edge Band (Rehau make). The TABLE`s Will Having
POP UP BOX as per Architects Specifications without
Top STONE/GLASS with Fitting of Required hardware,
Material like Nail (surya Make), Screw (Hettich/Hepo
make), Adhesive (Fevicol Make) Tools, Tackles &
labour Etc Work Complete as per Detail Drawings.
- Size: L 1450mm x H 750mm x D 900mm
Providing & Fixing of LINEAR WORKSTATION per
Detail Drawings/ Architects specifications. The top
made out From MR 303 Grade Plywood of 25 mm
thickness (Century/Green/Wigwam/CPL/Derby Make)
with Top Side Fixing of 19mm Thik Plywood, Vertical
Side fixing of 19/16mm Thick Plywood, Bottom side
Fixing of 19/12mm Thick Plywood with and Required
Back Side Fixing of 06mm Thick Plywood with Inside
Fixing of 0.8mm Thick Off White Laminate
(Timex/CPL make) with outer Surface Fixing of 1mm
Thick Approved Shade Laminate Vertical/Horizontal
Grains (timex/AICA/CPL/Century/Green/Dolby Make)
with Edge Side Fixing of 22/19/32/42mm Thick Edge
Band (Rehau make). As per Architects Specifications
without Top STONE/GLASS with Fitting of WIRE
MANAGER (SS/PVC) Required hardware, Material like
Nail (surya Make), Screw (Hettich/Hepo make),
Adhesive (Fevicol Make) Tools, Tackles & labour Etc
Work Complete as per Detail Drawings.
- Size of TABLE: L 1200mm x W 600mm x H 750mm
Supply & Installation of MODULAR PARTITION as
per Detail Drawings/architects Specifications.
The PARTITION will be having support of 75mm
aluminium partition with approved make, coated with
approved colour as per specifications given in drawing.
208 34.50 for LAN data and electrical purpose and to support the Sqm 9090.00
table with top sides covered with softboard and other
side with BPG combination approved by architect. and
bottom sides covered by 6 mm prelaminated panels as
per selected colour shade approved by architect.Modular
Partition ( - Size: L 1200mm x H 1200mm x T 75mm)
Supply & Installation of METAL KEYBOARD TRAY
Item Accoring to
but may be Item Work Unit Tender Rates
Supply & Installation of METAL CPU STAND of
Providing & Fixing of DINING TABLE with SIDE
TABLE as per Detail Drawings/ Architects
specifications.
The TABLE made out From 19mm Thick HIGH
COMPACT SHEET as approved make/ Color/ Shade/
Specifications/ Direction/ Detail Drawings with
Modification, Cutting Proper in Line. Level with Bottom
Side fixing of SS 304 FRAME (Squre Pipe of heavy
Duty) with Proper Buffing, Welding, Joint Welding in
Smooth Surface applicable with Fitting of Required
Tools, Tackles & Labour Etc Work Completed as per
Providing & Fixing of BASIN MIRROR with
FACTORY CUTTING as per Design with Fitting on SS
STUD 3"/2" Long with Edge Polish with Fitting of
Required hardware, Material & Labour Etc Completed
work as per Detail drawings and Architects
Specifications.
Providing & Fixing of WINDOW PELMENT as per
Detail Drawings/Architects specifications.
The PELMET made out From MR 303 Grade Plywood
(Century/Green/Wigwam/CPL/Derby Make) with Top
Side Fixing of 12mm Thik Plywood, Vertical Side
fixing of 12mm Thick Plywood, with Front Side Fixing
of Exteriors Grade 3.4mm THick MDF (Duna/Action
Tesa/Green Make) without Applying of PAINT with
Fitting of Required hardware, Material like Nail (surya
Make), Screw (Hettich/Hepo make), Adhesive (Fevicol
Make), Tools, Tackles & labour Etc Work Complete as
per Detail Drawings.
Curtain Providing, placing and installing in position in
true line and level Curtain along with required set of
214 312.00 accessories like pelmets etc. consisting of specified Sqm 4545.00
fabric,Complete as per details, as directed by Architect
and at all levels.
H/B Mesh CHAIR with BIFMA COMPLY and
following features: 360 Degree Swivel for ease of
motion, Tilt Tension Adjustment, Pneumatic height
Adjustment, ARMS height Adjustment, Synhrco-Tilt
Locking, Seat Glide Mechanism, Maximum Height:
1240 mm, Minimum Height : 1140 mm, Outer
Dimension: 640mm, Seat Deapth: 480 mm, Component
215 15.00 & Material: Breathable Mesh back with Cushoined Nos 11615.00
Fabric , Adjustable Lumbar Support & Armrest in PU,
Componet detail: PU Adjustable Handles, Chrome Base
& Nylon Castors, ERGONOMICS FEATURES:
Adjustable Lumbar Support on the Back, Any Position
Locking Mechanism, Adjustable Armrest with any
Position Lock. FIVE YEARS LIMITED WARRANTY
Durian, Godrej, Wipro or equivalent
H/B Mesh CHAIR with BIFMA COMPLY and
216 25.00 following features: 360 Degree Swivel for ease of Nos 11110.00
motion, Tilt Tension Adjustment, Pneumatic height
Item Accoring to
but may be Item Work Unit Tender Rates
Adjustment, ARMS height Adjustment, Synhrco-Tilt
Locking, Seat Glide Mechanism, Maximum Height:
1240 mm, Minimum Height : 1140 mm, Outer
Dimension: 640mm, Seat Deapth: 480 mm, Component
& Material: Breathable Mesh back with Cushoined
Fabric , Adjustable Lumbar Support & Armrest in PU,
Componet detail: PU Adjustable Handles, Chrome Base
& Nylon Castors, ERGONOMICS FEATURES:
Adjustable Lumbar Support on the Back, Any Position
Locking Mechanism, Adjustable Armrest with any
Position Lock. FIVE YEARS LIMITED WARRANTY
Durian, Godrej, Wipro or equivalent
M/B Mesh CHAIR with BIFMA COMPLY and
following features: 360 Degree Swivel for ease of
motion, Tilt Tension Adjustment, Pneumatic height
Adjustment, ARMS height Adjustment, Synhrco-Tilt
Locking, Seat Glide Mechanism, Maximum Height:
1040 mm, Minimum Height : 940 mm, Outer
Dimension: 610mm, Seat Deapth: 470 mm, Component
217 560.00 & Material: Breathable Mesh back with Cushoined Nos 11110.00
Fabric , Adjustable Lumbar Support & Armrest in PU,
Componet detail:PU Adjustable Handles, Chrome Base
& Nylon Castors, ERGONOMICS FEATURES:
Adjustable Lumbar Support on the Back, Any Position
Locking Mechanism, Adjustable Armrest with any
Position Lock. FIVE YEARS LIMITED WARRANTY
Durian, Godrej, Wipro or equivalent
M/B Mesh CHAIR with BIFMA COMPLY and
following features: 360 Degree Swivel for ease of
motion, Tilt Tension Adjustment, Pneumatic height
Adjustment, ARMS height Adjustment, Synhrco-Tilt
Locking, Seat Glide Mechanism, Maximum Height:
1040 mm, Minimum Height : 940 mm, Outer
Dimension: 610mm, Seat Deapth: 470 mm, Component
218 165.00 & Material: Breathable Mesh back with Cushoined Nos 6565.00
Fabric , Adjustable Lumbar Support & Armrest in PU,
Componet detail:PU Adjustable Handles, Chrome Base
& Nylon Castors, ERGONOMICS FEATURES:
Adjustable Lumbar Support on the Back, Any Position
Locking Mechanism, Adjustable Armrest with any
Position Lock. FIVE YEARS LIMITED WARRANTY
Durian, Godrej, Wipro or equivalent
Supplying of CANTEEN CHAIR as per Selection.
Product Type: Chair Colour: Customize Size: 16 x 16 x
219 64.00 36 inch Type: Cafe Chair Surface Finish: Powder Nos 5050.00
Coated Table Top Material: M S Iron
Seating Capacity: 1 Person Material: M S Iron
Providing & Fixing of CONFERENCE TABLE as per
Detail Drawings/ Architects specifications.
The CONFERENCE TABLE made out From MR
Grade Plywood (Century/Green/Wigwam/CPL/Derby
Make) with Top Side Fixing of 19mm Thik Plywood,
Vertical Side fixing of 19/16mm Thick Plywood,
Bottom side Fixing of 19/12mm Thick Plywood with
and Required Back Side Fixing of 06mm Thick Plywood
Item Accoring to
but may be Item Work Unit Tender Rates
with Inside Fixing of 0.8mm Thick Off White Laminate
(Timex/CPL make) with outer Surface Fixing of 1mm
Thick Approved Shade Laminate Vertical/Horzontal
Grains with Chamfer (Timex/ AICA/ CPL/ Century/
Green/ Dolby Make) with Edge Side Fixing of
22/19/32/42mm Thick Edge Band (Rehau make). The
TABLE`s Will Having POP UP BOX as per Architects
Specifications without Top STONE/GLASS with Fitting
of Required hardware, Material like Nail (surya Make),
Screw (Hettich/Hepo make), Adhesive (Fevicol Make)
Tools, Tackles & labour Etc Work Complete as per
Detail Drawings.
- Size: L 4260mm x H 750mm x D 1420mm
221 28.00 Supplying and fixing of of 8 MODULE POP UP BOX No. 6565.00
Providing & Fixing of RECEWAY For HIDDEN in
GRANITE with All Side Edge Polish with Back, Front,
222 175.00 Top & Bottom Side Fixing of 12mm Thick MR 303 Rmt 9595.00
Grade Plywood with Top Side Fixnig of GRANITE as
per Architects Specifications.
Supply & Installation of TABLE BOTTOM WIRE
UNIT as per Architects Specifications.
Plain gypsum board MRFR grade ceiling: Plain
gypsum MR& FR grade false ceiling Suspension(
considering all levels with require all fabricataion work
and fitiing from RCC slab to false ceiling up to
to600 mm & The rate shall be consider in sqm for all
floors and at all heights ,Offsets whether covelight or
fixed gypsum board size up to 100 mm to 1200 mm in
the false ceilings including all costs) . Work complete as
per the manufacturers specification of Saint Gobain -
M/F Suspended Ceiling 1 hour fire rated .:Providing and
fixing Suspended ceiling using Gypsum or equivalent of
ULtra G. I. Perimeter Channels of size 0.55mm thick
having one flange of 20mm and another flange of 30mm
and web 27mm along with perimeter of ceiling, screw
fixed to brick wall / partitions with the help of nylon
sleeves and screws, at min. 600 mm centers. Then
suspending G. I. intermediate channel of size 45mm,
0.9mm thick with two flanges of 15mm each from the
soffit at 1220mm centers with ceiling angle of width
25mm x 10mm x 0.55mm thick fixed to soffit with G. I.
cleat and steel expansion fasteners. Ceiling section of
0.55mm thickness having knurled web of 51.5mm and
two flanges of 26mm each with lips of 10.5mm are then
fixed to intermediate channel with the help of
connecting clip and in direction perpendicular to the
intermediate channel at 457mm centers. 12.5mm
gypsum MR/FR grade Board (conforming to IS
part 1 2011) is then screw fixed to ceiling section with
25mm dry wall screwed at 230mm centers. Screw fixing
is done mechanically either with screw driver or drilling
machine with suitable attachment. Finally the boards are
to be jointed and finished so as to have a flush look
which includes filling and finishing the edges of the
boards with jointing compound, Joint paper tape and two
Item Accoring to
but may be Item Work Unit Tender Rates
coats of Drywall top coat suitable for Gypsum Board.
Cutouts For light fittings, grill diffusers shall be made.
Necessary cutting / providing openings in the ceiling for
AC fixtures, grills, electrical fittings, or other utility
services, hatch openings etc. shall be provided by the
Contractor and cost of making such modifications shall
be included in the price. No separate charges for cutting
/ providing opening will be paid. Trap doors with
necessary ply frame work to be provided as required at
no extra cost.Joints between the two gypsum board,
(Board placed staggered) gypsum board and wall will
have suitable tape and finishes with plaster of paris so as
to have crack free joints.
Providing and Fixing of Light weight Calcium Silicate
Ceiling Tiles – Microlook edge of size 595x595x15mm
densified edge ,having 100% RH –High Heat &
Humidity Resistance) suitable for all weather conditions
, and Fire Performance - Non Combustible as per BS
476 part 4,Anti fungal & Antibacterial,Eco friendly,
Zero VOC, Non hazardoud, Noise Reduction Coefficient
of ranging from 0.5 NRC to 0.75NRC depending on the
Product, CAC of 32dB,Light reflectance above 85%,
density of 450 Kg/m3, Thermal Conductivity of
W/mo k C, to be laid on of true horizontal level 15 mm
exposed hot dipped galvanized steel sections in tech
panel Format where in main tee having a 150 Route fall
intersection notch for insertion of 150 mm Cross Tee
wherever Required to make a tech panel grid Format
with 150X 1200 MM Tech Panels of metal Gi plain
having Microlok Edge to incorporate all the services on
the tech panel and complete as desired by engineer
incharge.Necessary cutting / providing openings in the
ceiling for AC fixtures, grills, electrical fittings, or other
utility services, hatch openings etc. shall be provided by
the Contractor and cost of making such modifications
shall be included in the price. No separate charges for
cutting / providing opening will be paid. Trap doors with
necessary ply frame workto be provided as required at
no extra cost. Work complete as per the detailed
drawing and instruction of Architect/EIC.
Texture paint ( Insider and outside) :Wall painting two
coats with low VOC Jotashield Tex Ultra of Jotun or
Asian equivalent approved brand in any shades and
colour as directed on wall surface to give an even shade
including applying of a one coat of Penetrating prmer or
equivalent and two coats of paint, scaffolding to at any
height with all labour and material thoroughly brushing
the surface free from mortar droppings and other foreign
matter and sand prepared smooth etc. complete. The
substrate must be sound, clean, dry, free from dust, oil,
grease and laitance etc. All traces of release agents must
be removed. On chalky and dusty surfaces, all loose
material must be removed by stiff bristle brushing. The
primer / paint application is to be done with the rollers.
Item Accoring to
but may be Item Work Unit Tender Rates
rate shall be including crack filling and levelling as per
manufacturers specfication. Top coat should have. 1)
Low VOC content. 2) Crack Bridging ability upto
mm. 3) 100% pure acrylic emulsion 4) Anti-Carbonation
concrete protection 5) Very Low Flame spread 6)
Superior Washability
Providing and fixing fully perforated 12 MM MDF with
20% perforation of 9 mm dia fix on Gypsheera ™
0.5x48 mm metal stud place at 600 mm center to center
vertical and 1200 mm center to center horizontal fix
with periphery channel of Gypsheera ™ 50 mm with
require cavity and 12MM base frame to be fix on metal
227 275.00 channel, cavity filled by 50 MM X 1000 GSM synthetic Sqm. 6565.00
wool, complete systems cover with acoustic fabric. The
peripheral and intermediate members and the suspended
angles shall be designed for each area and the ceiling
detailed drawing shall be submitted to Client/Architect
in charge for approval prior to fabrication. Measurement
will be consider plan area.
Providing and fixing 12.5 mm fully perforated with 18%
perforation of 8 mm dia center to center (GYPROC /
Anutone) false ceiling supported on Gypsheera ™ CRP
surface ribbed perimeter and intermediate channels,
supported on self peripheral partition wall OR
suspended from the soffit at 1220mm centers with
Gypsheera ™ CRP surface ribbed ceiling angle fixed to
soffit with GI cleat and steel expansion fasteners(Mfg.
by Saint Gobain Gyproc).The ceiling section will be fix
with help of connecting clip perpendicular to intimidate
channel at 457mm C/C than Single layer of 12.5mm
tapered edge Gypboard® Plain (conforming to IS
part 1 1996) is then screw fixed to channel section at
designed spacing .All square and tapered edges of the
boards are to be jointed and finished so as to have a flush
look which includes filling and finishing with Gyproc
Jointing compound, Gyproc Joint Paper tape and laying
of 50 mm Synthetic wool. Finally apply plastic
emulsions colour of three coat selected by architect. The
peripheral and intermediate members and the suspended
angles shall be designed for each area and the ceiling
detailed drawing shall be submitted to Client/Architect
in charge for approval prior to fabrication. Measurement
will be consider plan area.
Providing and fixing 12.5 mm fully perforated with 15%
perforation of 12 mm hexagonal false ceiling supported
on Gypsheera ™ CRP surface ribbed perimeter and
intermediate channels, supported on self peripheral
partition wall OR suspended from the soffit at 1220mm
centers with Gypsheera ™ CRP surface ribbed ceiling
angle fixed to soffit with GI cleat and steel expansion
fasteners(Mfg. by Saint Gobain Gyproc).The ceiling
section will be fix with help of connecting clip
perpendicular to intimidate channel at 457mm C/C than
Single layer of 12.5mm tapered edge Gypboard® Plain
(conforming to IS 2095 part 1 1996) is then screw fixed
Item Accoring to
but may be Item Work Unit Tender Rates
to channel section at designed spacing .All square and
tapered edges of the boards are to be jointed and finished
so as to have a flush look which includes filling and
finishing with Gyproc Jointing compound, Gyproc Joint
Paper tape and laying of 50 mm Synthetic wool. Finally
apply plastic emulsions colour of three coat selected by
architect. The peripheral and intermediate members and
the suspended angles shall be designed for each area and
the ceiling detailed drawing shall be submitted to
Client/Architect in charge for approval prior to
fabrication. Measurement will be consider plan area.
Providing and fixing natural wood stage flooring 16 x
915 x 125 mm with tongue and groove fixing on 50 x
mm natural wood 600 x 600 gridwoork along with the
fixing 12 mm MR plywood on fabricated frame work
with require accessories, hardware and adhesive, cavity
should be filled by 24/50 mm glass wool than apply
wood protection mono coat on wooden plank with
require sealer. The peripheral and intermediate members
and the suspended angles shall be designed for each area
and the ceiling detailed drawing shall be submitted to
Client/Architect in charge for approval prior to
fabrication. Measurement will be consider plan area.
Providing and fixing over all 56 mm Acoustic door with
acoustic door seal using with 100 x 150 mm frame
surrounded 4 mm neoprine strip, wooden beading, door
make by 12 mm plywood and 12 mm board with require
perforation with infill of acoustic wool and 6 mm
flexibale acoustic sheet, one side finish of interior
surface and another side of laminet finish with essenisal
hardwae like doo handle, door spring, door stop, lathe
lock, etc as per under direction by client / architect in
charge with prior approval.
External Cladding Specification – Screens pattern using
SHERA Plank Supply& Installation external cladding
using fibre cement plank of SHERA make cassia/
straight grain/ teak texture (External Grade) thickness
8mm and dimension 150mmX3000mm. SHERA Fibre
cement plank should be of minimum density 1300kg/
m3 (±50) and comply to ASTM C 1185 and ISO
part (E) for confirming durability properties and BS
– part 5, 6 & 7, Thermal conductivity should be
minimum 0.15 W/m˚K and PH value should be in the
232 302.00 range of 7 – 8. Depending on height of structure SHERA Sqm. 2525.00
Board to be fixed using Aluminium rectangular frame
section of suitable gauge with minimum spacing 450mm
to 600mm or as per direction of Engineer Incharge,
SHERA Plank to be fixed using SHERA Screws of
Tensile strength 34N and Shear strength 68N on framing
maintaining distance of minimum 25mm between two
SHERA planks . All plank to plank joints to be
staggered and finished with one coat of cement based
primer on all side, with 2 coats of water based acrylic
paint of approved shade.
233 816.00 Providing and fixing full height Prelam PVC partition Sqm. 6363.00
Item Accoring to
but may be Item Work Unit Tender Rates
system 50mm thick consisting of 40mm sandwich PVC
panel made out of 36mm high density expanded
polystyrene sheet (E.P.S.Thermocol) stuck on both side
with 2mm thick prelim PvC sheet reinforced with frame
work made from 35mm x 5mm M.S. angle. In between
two M.S. angles 4 mm with feathered edges shall be
fixed on floor and 50 x 75 mm with feathered edges
prelim PVC “C” channel of size 50mm x 75mm with
feathered edges prelim PVC panel shall be inserted in
the PVC ‘C” channel The first and last M.S. angle
should be erected such that it is inside a PVC C channel
of size 50 x 75mm In between adjoining EPS
sandwiched PVC partition panel 4mm thick x 75 mm
width prelim PVC sheet feathered at edges shall be stuck
on front and back face using solvent cement etc. An
additional 4mm thick PVC strip of 40mm width is to be
stuck on the intrior side of the ‘C” channel using PVC
solvent adhesive completeas per direction of Engineer in
charge. Manufacture’s specification and drawing
Providing, Fabricating and Installing of Tensile Fabric
Structure, as Porch Area Covering, including fabrication
and installation of fabric canopy as per design and
details, using white colour 502 (590 GSM) architectural
structural fabric, by Serge Ferrari / Mehgies /Sattler or
equivalent, flame retardant, having polyester woven
scrim and topped with UV resistant layer, heat sealed at
joints and hot air or cyanoacrylate pasting other required
locations. MS pipe structure, composed of steel closed
hollow sections of ASIAN / TATA / SURYA or
equivalent brand, coated with two coats of zinc oxide,
duly painted with epoxy paint, using primer & selected
color finished top coat and other required
hardware including SS nuts, bolts, cables and other
required hardware as required per details, design, etc.
Providing, Fixing and installing all LED exterior light
fixtures of 90 Watt with Aluminium housing, toughened
235 0.00 glass cover and IP 56 rating of Hawells, Philips, Wipro Nos 10964.14
or equivalent make as per approval from architect. Unit
price of light fixture
Providing, Fixing and Installation of Motorised Vertical
Rolling Shutter Product: G.I. Motorized Rolling Shutters
Door Dimension Width: 8200 mm Height: 7500 mm
Max. Area: 120.0 Sq.mts. Opening Direction: Vertical
Opening/Closing Speed: 0.05-0.1mtr /sec Wind
Resistance: Up to90Km/ Hr Door Structure
Slat Material: CRC M.S/ G.I Steel Slats available in
236 10.80 mm thickness Slat Profile: Corrugated Profile RSC 88 Sqmt. 1908.90
Side Guide: Mild Steel/GI Side guides 150 mm wide
Bottom Profile: GI Bottom Plate with Angle Stiffener
Rubber bottom seal Roller Shaft: Heavy duty Mild Steel
strong suspension Tubular shaft without springs
Side Brackets: M.S plate 3 mm to 10 mm, as per the
opening dimension Hood Cover: Galvanized Steel sheet
Finish Surface Finish: Primer finish as standard
Item Accoring to
but may be Item Work Unit Tender Rates
Painting: Powder coating Details for Automation System
Control Type: Casing made of compact impact-resistant
material incorporating operating buttons for shutter
operation. Specific IP rating provided as per the
requirement. Deadman/Pulse Control suggested
application wise. Drive Type: Imported make Indirect
/Direct Connecting Drive selection made depending on
the space opening availability, no of operations
subjected etc. Drive with integral breaking system with
Long life expectancy CE Certified drives complying
European standard. Drive Unit: Electric Motor
(Imported Make) Three Phase Emergency Operation:
Manual operation by Hand chain or hand crank.
Providing and fixing acrylic Name plate of required size
on Room with lettering etc. complete as per instruction
of engineer in charge including all labour and material
Providing and fixing PRE ENGINEERED ROOF
comprising of galvalume sheets, steel structural trusses,
braces, framings etc. incorporating skylights, evaces,
gutters etc. and other ancillary components in desired
slopes and shapes, with sound proof and Thermal
insulation arrangement. Following are the principal
components and specs. 1) Built-up component of ASTM
A572M Grade 50 Type 1 of yield strength of 345MPa.
2) Hot rolled tubes as per IS 1161 of yield strength of
250 Mpa. Designing, fabrication, supply and erection of
Hot rolled members like ISMB, ISMC, tube sections and
pipe sections etc. with all labour, consumable, Plant,
Machinery etc. complete. 3) Exterior roof panel of
ASTM A792 M Grade 342 class 1 coating AZ150
(G550) of yield strength 550 Mpa. 4) Cold formed of
ASTM A653 M Grade 340 class 1 coating Z120-GI of
yield strength 340 Mpa. 5) X-Bracing rods as per IS
238 45.00 2062 of yield strength 250 Mpa., X-Bracing sq/rectangle Sqmt. 6615.50
hollow sections as per IS 4923 of yield strength of
Mpa. And X-Bracing angles as per IS 2062 of yield
strength of 250 Mpa. 6) Anchor bolts as per IS 2062-
UNPAINTED of yield strength 240 Mpa. 7) High
strength bolts as per IS 3757 Black Finished of yield
strength Gr. 8.8, 8) Connection Bolts as per IS
Yellow Chrome of yield strength Gr. 4.6, Surface
preparation include Wire Brush Cleaning and Paint
Application i.e., 1 coat of Primer and 2 coat of paint of
approved shade. Also on the steel structure, paint one
coat of red oxide (35 micron) & two coats of synthetic
enamel paint (25 micron each). In this PEB Structure
Size, quality/grade as specified above shall be strictly
adhered to no separate payment in terms of tonne will be
paid. The detailed design of the PEB frame structure will
be verified and approved by the authority appointed by
Providing and Fixing Sculpture of nearly 1.20 mt X
239 6.00 mt X 0.60 mt size of metal material and as per architect Nos 6464.00
design as directed by engineer in-charge.
Item Accoring to
but may be Item Work Unit Tender Rates
Providing and Fixing Sculpture reilif work of nearly
240 10.00 6.00 mt X 6.00 mt size on metal sheet and as per Nos 7575.00
architect design as directed by engineer in-charge.
Providing and Fixing tensile structure of modular, prefab
and panel build type of Steel and PVC material use in
seating arrangement, parking and building entrance,
having aluminium, galvanized, or steel pole material and
frame should be steel material easily assembled, and eco
241 25.00 Friendly waterproof material, weight (Gsm) 502, 602, Sqmt. 17927.50
702 , Tensile Strength 300 APH of any colour, plain
surface of surge Ferrari brand with 10 years warranty,
including fitting, labour, fixtures, fastening, and all type
of equipments, supporting poles, primer, painting etc.
complete as directed by engineer in charge.
Stainless Steel Dustbin (HOTC) (Steel Dusbin Pedal)
242 55.00 litres weight of dustbin:1200 grams. Lid: foot pedal Nos 3838.00
operated gripping provision frontal
Dustbin Mterial: LLDPE with 100 litres Bin Capacity.
Colour Green & Blue. Lid: Swing type
Supply, Installation and commissioning of machine
powder coated metal body factory finished movable
storage filing racks i.e., mobile compactors/ optimizers
with detail as follows: It should consists of storage units
of 381 mm deep – fixed or movable – bolted to
undercarriage which rolls onto the channels, which, are
firmly embedded to the ground with minimum 2 Rails
and 1 Bay and Drive type where Bay denotes side by
side unit placements in a block. Each compactor shall
have following type of blocks:
1. Single Static (SS)
2. Single Last (SL)
3. Twin Mobile (TM) - 2 body back to back.
Depth: 381 mm; Width: 915 mm; Height: 2360 mm +/-
15mm (Body excluding under structure and rails)
The body including shelves will be given antirust
surface treatment & are powder coated with epoxy
polyester powder. Final finish will consist of epoxy
polyester powder coating of approved colour & shade
with a Dry Film Thickness of minimum 40 microns.
Shelf will be made of 0.8 thick CRCA steel conforming
to IS:513 Gr. D or DD with max load bearing capacity
of 80 Kg uniformly distributed per shelf. Shelves will be
mounted on support brackets & shelf level adjustable at
approx. 25.4 pitch. There will be 5 adjustable shelves
per body giving 6 loading levels.
Painting lines, deashes, arrows, letters etc on roads, Air
fields and like in two coats with road marking paint,
brushing including cleaning the surface of all dirt, dust
and other foreign matter. (i) Over 10cm in width
Aluminium Composite Panel (ACP) Providing,
fabricating & installing in position 4mm thickness
0.25mm skin aluminium composite cladding of
"PIONEER, ALUTECH, ALSTRONG" are
protected with self adhesive protection film by erecting
over the wall using aluminium frames @ desired levels
Item Accoring to
but may be Item Work Unit Tender Rates
made with 50 x 25 x 1.2mm extruded channel
sections confirming to IS-7333 mechanical properities.
The frame shall be fixed on external wall surface with
necessary brackets, bolt nut arrangements with screws
aluminium L cleats, backer rod, wacker / dowcorning
silicon sealant etc., @ all levels & heights & silicon
sealant is filled in complete as per specification & shop
drawings, in case ACP sheet curve/bending cost charged
ACP Sheet Cladding MS Frames Pillars 100 x 100 14g-
Tube Pillars Support & Runner 80 x 40 14g Tube.
247 85.85 Runner Middle supporting 50 x 50 16g.Tube. Sqmt. 4646.00
Pillars base plate & Anchor Bolt. ( Civil Foundation to
be provided by Civil Contractor).
Scaffolding Charges for Canopy work & ACP Cladding
Work.(Double bamboo Scaffolding)
TOUGHENED GLASS FRAMELESS PARTITIONS
Design,Providing, installation and fixing 12 mm thick
Toughened Glass (Glass Make:- Saint Gobain, Asahi
India Glass etc.) partitions upto 3.00 M with proper
machine edge finish in angle & fixed in the flooring with
Aluminium 'U' channel & flushed with the ceiling. Glass
panels to be formed as per approved modules 12 mm
thick clear toughened glass edge polished and accurate
designed holes to be installed by means of steel angle or
spider fittings of an approved make Saint Gobain / Asahi
or equivalent. The structural Glass walls system shall be
complete with proper water tight silicon sealants
/gaskets. M.S Brackets to support the structure system
shall be hot dipped galvanized and slots in the brackets
to be pre drilled not flame cut. All bolts,nuts,washers
shall be 300 series non magnetic stainless steel and lock
washers to be provided at all bolting connections. All
anchor fasteners shall be of Hilti/Fisher make. All
structural silicone shall be of Dow Corning make. The
Rates includes all material, Labour, Wastages, Cost of
scaffolding,fixing & Finishing with frosted design film
TOUGHENED GLASS FRAMELESS DOORS
Design,Providing, installation and fixing 12 mm thick
Toughened Glass (Glass Make:- Saint Gobain/ Asahi
glass India) DOORS upto 2.10 M with all as per
required arrangement & proper machine edge finish in
angle & fixed in the flooring side with Aluminium 'U'
channel . Glass panels to be formed as per approved
250 181.44 modules 12 mm thick clear toughened glass edge Sqmt. 8080.00
polished and accurate designed holes to be installed by
means of steel fittings of an approved make Saint
Gobain / Asahi or equivalent. Including Floor spring
(make:- Godrej, Dorma or equivalent), Lock approved
make, Door Handle both side(SS make), all works
including labour, wastages, cost of scaffolding, finishing
with frosted design film etc. complete.
Electrification Work
251 22.00 Point wiring for Two Way Controlled Light Point with pt 603.98
Item Accoring to
but may be Item Work Unit Tender Rates
2-1.5 sq.mm & earth wire of 1.5 sq.mm (green) both are
of .ISI marked 1.1 KV grade FRLS PVC insulated multi
strand copper wires erected in below type of pipe with
6A Modular type switches and following type of
accessories erected on PVC / Metallic/Wooden box,
single mounting base frame covered with textured /
metallic/white front plate modules erected on / in wall /
ceiling as per pipe erected. with necessary batten/angle
holder or ceiling rose or H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete - CAT III
Point wiring for Light / Bell with 2-1.5 sq.mm & earth
wire of 1.5 sq.mm (Green) both are of ISI marked
KV grade FRLS PVC insulated multi strand copper
wires up to 10 mtr length , in below type of pipe erected
with 6A Modular type switch / bell push & accessories
and earth continuity of following type, erected on PVC /
252 1409.00 Metallic/Wooden box, single mounting base frame Pt 485.81
covered with textured/metallic/white front plate modules
erected on / in wall / ceiling as per pipe erected, with
necessary Lamp holder/ceiling rose / H.D.Connector as
(f) with medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete - CAT III
Point wiring for FAN with 2-1.5 sq.mm & earth wire of
1.5 sq.mm (Green) both are of .ISI marked 1.1 KV
Grade FRLS PVC insulated multi strand copper wires
up to 10 mtr length, in below type of pipe erected with
6A Modular type switch and hum free EME step type
electronic fan regulator mounted and accessories with
253 342.00 earth continuity of following type erected on PVC / pt 674.68
Metallic/Wooden box, single mounting base frame
covered with textured/metallic/white front plate
modules erected on / in wall / ceiling as per pipe erected.
with necessary ceiling rose / H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete
Point wiring for Individual Plug with & earth wire of
1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade
FRLS PVC insulated multi strand copper wires up to
mtr length, in below type of pipe erected complete with
Modular type switch & 5 pin Plug erected on PVC /
Metallic/Wooden box covered with appropriate front
plate modules erected on / in wall / ceiling as per pipe
erected with following type of accessories.
[I] For 6A Plug and 6 a switch with 2-1.5 sq.mm Cu.
Wire from nearby switchboard/mcb db board
(F) with medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete Cat. III
Point wiring for Individual Plug with & earth wire of
1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade
FRLS PVC insulated multi strand copper wires up to
mtr length, in below type of pipe erected complete with
Modular type switch & 5 pin Plug erected on PVC /
Metallic/Wooden box covered with appropriate front
Item Accoring to
but may be Item Work Unit Tender Rates
plate modules erected on / in wall / ceiling as per pipe
erected with following type of accessories.
[II] For 16A Plug and 16 amp switch with 2-2.5 sq.mm
Cu. Wire from mcb db board.
(F) with medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete Cat. III
Point wiring for on board Looped Plug with 6A Modular
type switch & 5 pin socket erected on PVC /
Metallic/Wooden box, single mounting base frame
covered with textured / metallic/white front plate
modules erected on / in wall / ceiling with following
type accessories catt-iii
Providing and erecting ISI mark Medium class RIGID
PVC PIPES of following size complete to be erected
on/in wall or ceiling erected with necessary PVC
fittings & Junction boxes fixed with adhesive solution &
Clamps with following dia of pipes, in approved manner
as directed (b) 25 mm
Providing and erecting ISI mark Medium class RIGID
PVC PIPES of following size complete to be erected
on/in wall or ceiling erected with necessary PVC
fittings & Junction boxes fixed with adhesive solution &
Clamps with following dia of pipes, in approved manner
as directed (b) 40 mm
Providing & erecting PVC Corrugated Flexible Conduit
259 685.00 with required nos. of coupling, PVC bushes, Check-nuts mtr. 21.21
etc. complete of following sizes. (2) 25 mm
Supplying under floor pregalvanised corrosion proof
rectangular sheet steel cable trunking of 1.6 mm thick
having with stand point load up to 1.33 Ton & free from
seepage of concrete of screed water with all
accessories,Junction Box,Joints as required and
260 450.00 demanded by engineer-incharge and laying/erecting as mtr. 1342.29
per OEM guidelines and as per instruction of engineer
incharge having following size of dimensions and No of
compartments (W x D x T) Cat-III
[13] 300mm x 38mm x 1.6 mm with Three
Providing and erecting Mains with 1.1 KV grade FRLS
PVC insulated ISI marked stranded Copper conductor
wire in following type of pipe to be erected concealed
in /flushed on wall/ceiling, with 1.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green
colour for earth continuity of following size (A) With
medium class Rigid PVC pipe and accessories(a) 2 wire
providing and erecting Mains with 1.1 KV grade FRLS
PVC insulated ISI marked stranded Copper conductor
wire in following type of pipe to be erected in / on wall /
ceiling with 2.5 sq. mm copper conductor FRLS PVC
insulated stranded wire of green colour for earth
continuity of following size (A) with medium class
Rigid PVC pipe and accessories .
(g) 4 wire 4 sq. mm
Item Accoring to
but may be Item Work Unit Tender Rates
Supplying and erecting Flexible PVC insulated multi
strand multi core 1.1 kv grade ISI marked copper wires
of following size to be erected as directed.
(e) 1.50 Sq.mm 3 core round PVC sheathed
providing and erecting Mains with ISI marked, 1.5KV
grade electrolyte multi stranded, annealed copper
conductor with heat resistant PVC insulated conforms to
IS 694, IEC - 227 erected in existing pipe of following
size (Specifically for control panel, relays, power
switchgears, motor starters & control wiring) with
required size of copper lugs, nuts and bolts if required.
(d) One wire 4.00 sq. mm
267 140.00 (e) One wire 6.00 sq. mm Mtr. 56.56
268 140.00 (f) One wire 10.00 sq. mm Mtr. 91.91
269 140.00 (g) One wire 16.00 sq. mm Mtr. 142.41
Providing & erecting Switch board for Computer or
electric apparatus consisting of following modular type
accessories mounted with PVC / Metallic
concealed/open box with single mounting base frame
270 165.00 covered with textured/metallic /white front each 1133.22
plate,modules erected with necessary connections as
1 no. 6A/16A universal plug-switch combined.
3 nos. 6A Switch 3 nos. 6A 5 pin Plug , CAT- III
Supplying & erecting Approved make call bell indicator
with buzzing sound and Red light indicating lamp with
Red light button to attend the call suitable for 240 v
c/s supply to be erected.
Supplying and erecting LED indoor fittings with LEDs
of wattage 0.2 Watt to 0.5 Watt assembled on single
MCPCB, with housing used as a heat sink shall be made
of thick sheet Steel conforming to IS: 513/CRCA/
aluminium pressure die cast powder coated and high
U.V. & corrosion resistance with diffuser housed in
aluminium casted body with company mark/name 160V
to 270V, Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K, Luminaire efficacy>
lumens/watt, LED driver efficiency > 85 %
(fitting required LM-79 & LM-80 Certificates)(NOTE:
Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may
select any wattage capacity between the ranges shown.)
(A) Square/ Circular shaped Surface/Recessed Mount
Downlight with provision for spring loaded mounting
clips complete.IP2
(iv) 22-24 watts, Surge-2 KV
273 150.00 (ii) 11-15 watts, Surge-2 KV each 427.23
Supplying and erecting LED street light / Flood light
fittings with High power White LEDs wattage of 3 Watt
and above assembled on single MCPCB, efficiency
274 105.00 more than 130 lm/w and corrosion free High pressure each 3345.12
die cast aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with diffuser
and Polycarbonate optics/ lenses, with toughened glass
Item Accoring to
but may be Item Work Unit Tender Rates
with company mark/name engraved or embossed 160 to
270 V,Power Factor more than 0.95, THD < 10 %, CCT
3000 K to 5700K,Uniformity ratio >0.45, Luminaire
efficacy> 100 lumens/watt . LED driver efficiency >
85%. (fittings required LM-79 & LM-80
certificates)(NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The
Engineer incharge may select any wattage capacity
between the ranges shown.)(A) Street Light (IP-65),
Surge protection -4KV integral and ,Light must have
440VAC line supply with over-voltage protection. (iv)
above 36 to 48 watts.CATT-III
providing and erecting Approved make Double Pole
275 70.00 Plastic Switch and fuse 250V., 30A confirming to IS each 129.28
erected on Polished wooden block as directed.
providing and erecting Approved make Three Phase &
Neutral LT Heavy Duty Switch Disconnector Fuse Unit
Cubical type for panel mounting complete with
276 1.00 operating mechanism suitable to operate on 415V A.C. , each 8141.61
23A duty With HRC fuses of suitable load confirming
to IS. 13947 (Part I & III). of following capacities. (e)
providing and erecting Miniature circuit breaker single
pole 6A to 25A suitable to operate on 240 V A.C.
277 1854.00 system and having breaking capacity 10 KA to be each 112.11
erected in existing box. confirming to IS 8828/1996 with
ISI Mark Cat.III
Providing & erecting 240 V MCB double pole switch
for motor & inductive load (C Curve) having 10 KA
278 65.00 breaking capacity & confirms to IS : 8828 in existing each 299.97
box having following capacity (A) 6 to 32 Amp.
Providing & erecting 240 V MCB double pole switch
for motor & inductive load (C Curve) having 10 KA
279 65.00 breaking capacity & confirms to IS : 8828 in existing each 330.27
box having following capacity (B) 40 Amp.
Providing & erecting 415 V MCB Four Pole for Motor
& Inductive Load (C Curve) having 10KA breaking
280 55.00 capacity & confirms to IS :8828 in existing box having each 595.90
following capacity
(a) 6 to 32 Amp. Cat.III
Providing & erecting 415 V MCB Four Pole for Motor
& Inductive Load (C Curve) having 10KA breaking
281 55.00 capacity & confirms to IS :8828 in existing box having each 668.62
following capacity
(b) 40 Amp. Cat.III
Providing & erecting 415 V MCB Four Pole for Motor
& Inductive Load (C Curve) having 10KA breaking
282 65.00 capacity & confirms to IS :8828 in existing box having each 737.30
following capacity
(c) 63 Amp. Cat.III
Providing & erecting 415 V MCB three Pole for Motor
283 65.00 & Inductive Load (C Curve) having 10KA breaking each 587.82
capacity & confirms to IS :8828 in existing box having
Item Accoring to
but may be Item Work Unit Tender Rates
following capacity
(a) 6 to 32 Amp. Cat.III
Providing & erecting 415 V MCB three Pole for Motor
& Inductive Load (C Curve) having 10KA breaking
284 41.00 capacity & confirms to IS :8828 in existing box having each 647.41
following capacity
(b) 40 Amp. Cat.III
Providing & erecting 415 V MCB three Pole for Motor
& Inductive Load (C Curve) having 10KA breaking
285 56.00 capacity & confirms to IS :8828 in existing box having each 716.09
following capacity
(c) 63 Amp. Cat.III
Supplying & erecting 20 Amp 10 KA ‘C Curve’ single
pole MCB with 20 Amp. Plug socket, company
286 70.00 fabricated powder coated sheet steel enclosure erected as each 527.22
directed with connection. [A] Metal Clad Socket with
metal clad top Cat.III
Supplying & erecting approved make Electronics Starter
and relay for air conditioners in ABS plastic moulded
housing. Company fabricated with bakelite terminal for
connection with silver coating bimetallic contact in
switching device for o/p with following features.
287 6.00 (1) Low Voltage Protection below 130 V each 886.78
(2) High Voltage protection above 270 V
(3) Overload protection for 2-5, 4-10, 8-14, 10-16, 14-22
Amp. (inverse time chara-)
(4) Indicating LEDs for AC on LV, HV, O/L, T/D
(5) With unique feature of 3 minute of time delay.
3-11-1. Half / One Module Blanking Plate of Standard
3-11-2. Plastic enclosure fitted with DIN rail suitable for
incorporating One / Two nos. MCB
3-11-3.Plastic enclosure fitted with DIN rail suitable for
incorporating Three /Four nos. MCB
3-11-4.Sheets steel powder coated enclosure suitable for
incorporating One/Two nos. MCB.
Providing and erecting Sheet Steel powder coated MCB
distribution board - flush / surface mounted fitted with
busbar, neutral link, earth bar and DIN rail, Conforms to
IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house
292 2.00 appropriate nos. of MCBs.(The DBs should be used of each 1152.41
same company of MCB to be used) suitable for
(A) single phase incoming and horizontal single phase
(b) sheet steel double door (IP-43) (iii) 8 way
Providing and erecting Sheet Steel powder coated MCB
distribution board - flush / surface mounted fitted with
busbar, neutral link, earth bar and DIN rail, Conforms to
IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house
293 2.00 appropriate nos. of MCBs.(The DBs should be used of each 3412.79
same company of MCB to be used) suitable for
(B) three phase incoming and single phase horizontal
type outgoing Per phase isolation type (PPI)
(b) sheet steel double door (IP-43) (iii) 8 way
294 21.00 Supplying & erecting Sheet Steel powder coated Cable each 689.83
Item Accoring to
but may be Item Work Unit Tender Rates
end termination Box to be mounted on Top or Bottom
of the MCB Distribution Box for housing/covering Extra
wires & Cables, suitable for following size of MCB DB
(G) Three Phase 8 Way
Supplying & erecting Sheet Steel powder coated Cable
end termination Box to be mounted on Top or Bottom
of the MCB Distribution Box for housing/covering Extra
wires & Cables, suitable for following size of MCB DB
(H) Three Phase 12 Way
Providing & erecting approved make thermo plastic
MCB/RCCB distribution board having modular Double
door with DIN rails, epoxy powder coated finish metal
frame & door assembly with Acrylic/ Plastic door,
spring & hinged pins complete with required PVC
sleeved 32 / 63A copper Bus strips without MCB /
(e) Two Row 28 Module
Providing and erecting Sheet Steel powder coated
Vertical MCB distribution board (VTPN) - flush /
surface mounted double door (IP54) fitted with insulated
copper busbar, isolated neutral link, earth bar and DIN
rail, confirming to IS 13032 and BS 5486-1986,IP-54
suitable for 63/100 AMP TPN MCCB + RCCB as
incomer and three phase outgoing as per following
.(The DBs should be used of same company of MCB to
(D)12 way outgoing
Providing and erecting powder coated distribution board
with WI-FI - flush / surface mounted double door (IP-
42) fitted with size 475*398,CRCA sheet thickness
0.9mm,Genral Tolerance,Power Coting DFT 60-90
micron,Frame Thickness 1.2mm.,Frame & Cover
Material Metal with Nessesary Accessories
Supplying & erecting approved make RCCB + MCB
(Electro magnetic type only) working on residual current
device having 10 KA short circuit breaking capacity and
30 mAmp. Sensitivity & 30 mili sec. tripping time
299 65.00 conforming to IS 12640 test knob facility trip free each 1944.25
mechanism operating for rated leakage at nominal ten
volt, complete erected including all materials lugs
screws etc. completed. [b] 32A / 40A, 2 pole Single
Supplying & erecting approved make RCCB + MCB
(Electro magnetic type only) working on residual current
device having 10 KA short circuit breaking capacity and
30 mAmp. Sensitivity & 30 mili sec. tripping time
300 65.00 conforming to IS 12640 test knob facility trip free each 2338.15
mechanism operating for rated leakage at nominal ten
volt, complete erected including all materials lugs
screws etc. completed.
[c] 63 A, 2 pole Single Phase Cat. II
Providing and erecting metallic vitrified danger notice
board as per language suggested by engineer incharge
Item Accoring to
but may be Item Work Unit Tender Rates
for HIGH VOLTAGE installation to be erected as per
Providing & erecting High Voltage Danger Notice
302 30.00 Board sticker as per language suggested by engineer each 35.35
incharge of standard size-as per IS
Providing and erecting required size HOT deep
Galvanised iron strip for earthing of H.T. , OCB/ ACB/
Transformer LT panel board, Motors etc. using proper
Providing and erecting required size Copper strip for
304 787.00 earthing of H.T. OCB / ACB/ Transformer, LT panel each 151.50
board, Motors etc. using copper clamp.
Providing and erecting Annealed bare Copper wire 8 to
Supplying & erecting in earthpit of minimum bore dia.
225mm size approved make Safe Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS 3043-1987
made of corrosion free hot dipped G.I.Pipes having
Outer pipe dia of 80 mm having 80-200 Micron
galvanising, Inner pipe dia of 40 mm having 200-250
Micron galvanising, connection terminal dia of
mm with constant ohmic value surrounded by highly
conductive compound with high charge dissipation
suitable for following type of applications with chamber
and heavy duty cover (A)(approved make OEM has to
submit test certificate including value of earth resistance
of installation duly stamped and signed by agency and
officer Incharge has to ensure the value of earthing
resistane mentioned in test Certificate) & having back
filling compound of (B) Inner chemical (CCM
Compound)- Resistivity:- 0.2 ohm / meter testing as per
IEC 62561-2017, Voltage drop:- < 1 volt at no load &
dry form, Sulphar content:- <2%(C) Back fill
Compound :- Earthing compound should be capable to
retain moisture for long time Necessary test report must
be submitted by Agency.
[B] For Electrical installation up to 11 KV located in
other than normal soil i.e. Soft Rock, Marshy Soil etc.
-Length of Pipe : 2 mtr
-Back filling Compound :1 no. Bag of 25 Kg
Supplying & erecting in earthpit of minimum bore dia.
225mm size approved make Safe Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS 3043-1987
made of corrosion free hot dipped G.I.Pipes having
Outer pipe dia of 80 mm having 80-200 Micron
galvanising, Inner pipe dia of 40 mm having 200-250
Micron galvanising, connection terminal dia of
307 10489.00 mm with constant ohmic value surrounded by highly each 15.15
conductive compound with high charge dissipation
suitable for following type of applications with chamber
and heavy duty cover (A)(approved make OEM has to
submit test certificate including value of earth resistance
of installation duly stamped and signed by agency and
officer Incharge has to ensure the value of earthing
resistane mentioned in test Certificate) & having back
Item Accoring to
but may be Item Work Unit Tender Rates
filling compound of (B) Inner chemical (CCM
Compound)- Resistivity:- 0.2 ohm / meter testing as per
IEC 62561-2017, Voltage drop:- < 1 volt at no load &
dry form, Sulphar content:- <2%(C) Back fill
Compound :- Earthing compound should be capable to
retain moisture for long time Necessary test report must
be submitted by Agency.
[C] For Electrical Installation covering Transformer
Neutrals, Lightning arrester Earthing, A.C. Plant &
Sensitive Computer System (like Automation,
SCADA)i.e. independent Earthing located in other
than normal soil i.e. Soft Rock, Marshy Soil etc..
-Length of Pipe : 3 Mtrs.
-Back filling Compound :2 nos Bags of 25 Kg.
Providing one bag of 25 Kg. Additional Back Filling
Compound (BFC) suitable for safe earthing device.
Supplying & erecting XLPE(IS:7098)(I)-88 ISI
309 1250.00 unarmoured copper cable 1.1 KV grade to be erected as Mtr 101.00
directed of following size. (A) 2 core 2.5 Sq. mm
Supplying & erecting XLPE(IS:7098)(I)-88 ISI
310 1050.00 unarmoured copper cable 1.1 KV grade to be erected as Mtr 131.30
directed of following size. (B) 2 core 4 Sq. mm
Supplying & erecting XLPE(IS:7098)(I)-88 ISI
311 1250.00 unarmoured copper cable 1.1 KV grade to be erected as Mtr 137.36
directed of following size. (E) 3 core 2.5 Sq. mm
Supplying & erecting XLPE(IS:7098)(I)-88 ISI
312 2150.00 unarmoured copper cable 1.1 KV grade to be erected as Mtr 188.87
directed of following size. (F) 3 core 4 Sq. mm
Supplying & erecting XLPE(IS:7098)(I)-88 ISI
313 2150.00 unarmoured copper cable 1.1 KV grade to be erected as Mtr 292.90
directed of following size. (G) 3 core 6 Sq. mm
Supplying & erecting XLPE(IS:7098)(I)-88 ISI
314 150.00 unarmoured copper cable 1.1 KV grade to be erected as Mtr 573.68
directed of following size. (M) 4 core 10Sq. Mm
Supplying & erecting XLPE(IS:7098)(I)-88 ISI
315 150.00 unarmoured copper cable 1.1 KV grade to be erected as Mtr 728.21
directed of following size. (N) 4 core 16Sq. Mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Aluminium conductor for
316 200.00 1.1 KV. to be laid on wall with necessary clamps or in Mtr 220.18
existing trench / pipe of following size of cables
(B) 3 1/2 core 35 Sq. mm ( 16 Sq.1/2 mm core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Aluminium conductor for
317 150.00 1.1 KV. to be laid on wall with necessary clamps or in Mtr 284.82
existing trench / pipe of following size of cables
(C) 3 1/2 core 50 Sq. mm ( 25 Sq.1/2 mm core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Aluminium conductor for
318 250.00 1.1 KV. to be laid on wall with necessary clamps or in Mtr 378.75
existing trench / pipe of following size of cables
(D) 3 1/2 core 70 Sq. mm ( 35 Sq.1/2 mm core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI
319 650.00 armoured cable multistrand Aluminium conductor for Mtr 490.86
1.1 KV. to be laid on wall with necessary clamps or in
Item Accoring to
but may be Item Work Unit Tender Rates
existing trench / pipe of following size of cables
(E) 3 1/2 core 95 Sq. mm ( 50 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Aluminium conductor for
320 450.00 1.1 KV. to be laid on wall with necessary clamps or in Mtr 731.24
existing trench / pipe of following size of cables
(G) 3 1/2 core 150 Sq. mm ( 70 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Aluminium conductor for
321 650.00 1.1 KV. to be laid on wall with necessary clamps or in Mtr 904.96
existing trench / pipe of following size of cables
(H) 3 1/2 core 185 Sq. mm ( 95 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Aluminium conductor for
322 250.00 1.1 KV. to be laid on wall with necessary clamps or in Mtr 1168.57
existing trench / pipe of following size of cables
(I) 3 1/2 core 240 Sq. mm( 120 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Aluminium conductor for
323 165.00 1.1 KV. to be laid on wall with necessary clamps or in Mtr 1407.94
existing trench / pipe of following size of cables
(J) 3 1/2 core 300 Sq.mm ( 150 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Copper conductor for
324 850.00 KV. to be laid on wall with necessary clamps or in Mtr 287.85
existing trench / pipe at road crossing or floor of
following size of cable. (B) 3 core 4 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Copper conductor for
325 150.00 KV. to be laid on wall with necessary clamps or in Mtr 395.92
existing trench / pipe at road crossing or floor of
following size of cable. (C) 3 core 6 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Copper conductor for
326 400.00 KV. to be laid on wall with necessary clamps or in Mtr 676.70
existing trench / pipe at road crossing or floor of
following size of cables. (A) 4 core 10 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Copper conductor for
327 150.00 KV. to be laid on wall with necessary clamps or in Mtr 987.78
existing trench / pipe at road crossing or floor of
following size of cables. (B) 4 core 16 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Copper conductor for
328 250.00 KV. to be laid on wall with necessary clamps or in Mtr 1504.90
existing trench / pipe at road crossing or floor of
following size of cables. (C) 4 core 25 Sq. mm
Making trench in Hard Murrum / Tar Road of suitable
width of 90 cm or required depth for laying any size of
329 250.00 cable or locating the fault all over the run and back Mtr 74.74
filling the same and making the surface as normal
Making trench in Hard Murrum / Tar Road of suitable
330 150.00 width of 90 cm or required depth for laying any size of Mtr 357.54
cable or locating the fault all over the run and back
Item Accoring to
but may be Item Work Unit Tender Rates
filling the same and making the surface as normal
(B) If additional machinery like hammer driller or JCB
Covering of cable with second class bricks or cement
tiles laid cover the cable crosswise & also on both sides
with covering of 7. 5 Cm. layer of sand above & below
cable (16 bricks per meter)
Drilling the road without breaking the road surface
(Asphalt) for laying of cable for feeding power supply
332 50.00 by making up to following size of holes at both ends Mtr 616.10
(B) Up to 150 mm bore dia
Providing and erecting iron clad cable route marker duly
marked with ELE.CABLE of size 23 cm.X 12 cm.
Flushed with ground in cement foundation as directed by
Engineer in charge.
Providing & laying. R.C.C. Hume pipe for cable to be
laid 90 cm. below ground across the road crossing or on
floor with necessary material in an approved manner and
making the ground as per original. (A) 450 mm dia
Providing & laying approved make Double walled
corrugated pipes (DWC) of polyethylene(conforming to
IS 14930 II )with necessary connecting accessories of
same material at required depth in existing trench for
laying of cable. below ground / road surface for
enclosing cable (D)120 mm outer dia.
Providing & laying approved make ISI marked HDPE
6Kg / cm2 (Class-3) as per IS:4984:1995 PE-80 to be
336 60.00 erected at road crossing on or floor as directed for laying Mtr 732.25
of cable. The pipes as following size of dia & weight per
6 mtr. (F) 110 mm inner Dia.
Providing and, fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured
337 150.00 cable complete without going tails, insulating tape etc EACH 33.33
for following size of cables.
(A) 2 to 4 core 2.5 / 4 Sq. mm
338 100.00 (B) 2 to 4 core 6 Sq. mm EACH 38.38
339 75.00 (C) 2 to 4 core 10 Sq. mm EACH 38.38
340 35.00 (D) 2 to 4 core 16 Sq. mm EACH 47.47
341 35.00 (E) 2 to 4 core 25 Sq. mm EACH 51.51
Providing and, fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured
342 35.00 cable complete without going tails, insulating tape etc EACH 75.75
for following size of cables.
(B) 3 & 1/2 core 35/50 Sq. mm
Solder less crimping type Aluminium lugs conforming
348 75.00 to IS suitable for cable of following size evenly crimped EACH 20.20
with high pressure tool & connected to switchgear
Item Accoring to
but may be Item Work Unit Tender Rates
terminals with brass/cadmium plated nut bolts in an
approved manner. (D) 35/50 Sq.mm.
Solder less crimping type Copper lugs conforming to IS
suitable for cable of following size evenly crimped with
354 200.00 high pressure tool & connected to switchgear terminals EACH 8.08
with brass/cadmium plated nut bolts in an approved
manner. (A) 1.5/2.5 to 6 Sq.mm
Providing and fixing approved make Perforated C type
cable tray. Made from sheet steel. The cable tray
should be single or double bended as per required and as
per IS 2062/1079 and shall be coated with hot dip
galvanizing as per IS 2629/4759. with max 17.5%
perforation with coupler plate / Fish plate and GI
hardware like nut - bolt and washers etc. erection with
necessary support( included) as per Specification and as
per instruction of engineer in charge..
(5) 300 X 50 X 2.0 mm Thick
Providing and fixing approved make 'T' Junction for
Perforated C type cable tray. Made from sheet steel.
The Junction should be bended as per IS 2062/1079 and
shall be coated with hot dip galvanizing as per IS
360 10.00 2629/4759. with max 17.5% perforation with coupler EACH 291.89
plate / Fish plate and GI hardware like nut - bolt and
washers etc. erected on existing support as per
Specification and as per instruction of engineer in charge
of following size (5) 300 X 50 X 2.0 mm Thick
Providing and fixing approved make '90° Elbow' for
Perforated C type cable tray. Made from sheet steel.
The Junction should be bended as per IS 2062/1079 and
shall be coated with hot dip galvanizing as per IS
362 10.00 2629/4759. with coupler plate / Fish plate and GI EACH 245.43
hardware like nut - bolt and washers etc. erected on
existing support as per Specification and as per
instruction of engineer in charge.. (5) 300 X 50 X
mm Thick 90° Elbow
363 10.00 (6) 450 X 50 X 2.0 mm Thick 90° Elbow EACH 446.42
Providing and fixing approved make '90° Elbow' for
Perforated C type cable tray. Made from sheet steel.
The Junction should be bended as per IS 2062/1079 and
shall be coated with hot dip galvanizing as per IS
2629/4759. with coupler plate / Fish plate and GI
hardware like nut - bolt and washers etc. erected on
existing support as per Specification and as per
instruction of engineer in charge.. (5) 300 X 50 X
Item Accoring to
but may be Item Work Unit Tender Rates
mm Thick Cross Junction
365 10.00 (6) 450 X 50 X 2.0 mm Thick Cross Junction EACH 673.67
Supply, Installation, Testing and Commissioning of
suitable sweep, BEE 5 Star rated, Ceiling fan with Brush
Less Direct Current (BLDC) permanent ferrite magnet
Motor, class of insulation: B, Rust free 3 nos.Aluminium
blades, 2 nos. canopies, shackle kit with earthing
provision, copper winding, Power factor not < 0.9,
Service Value (CMM/W) minimum 6.85, Air delivery
minimum 215 CMM, 350 RPM,230v (tolerance as per
366 324.00 IS : 374-2019), THD < 10%, compitible with electronic each 2629.03
regulator unit for Speed Control and all remaining
accessories including safety pin, nut bolts, washers,
temperature rise = 75 degree C (Max.), suitable for
to 285 Voltage and rectifier circuit with surge, over
current and overload protection , 50 Hz, Single phase
AC Supply, earthing etc. Complete as required.[ Make
shall be approved by Engineer in Charge] (A) 1200 mm
Supplying and erecting 19 / 20 mm. nominal bore
Medium Class M.S. Pipe down rod erected duly painted
for fan complete with proper insulation without leakage
Supplying & erecting Fan Hook of 10 mm M.S. Round
368 324.00 bar grouted in RCC slab with Making the site as each 43.43
Supplying & erecting single phase approved make
industrial exhaust fan suitable for medium duty ring
369 55.00 mounted low noise operation suitable for medium duty each 2054.34
having following dia size and maximum speed in RPM
[A] 305 mm dia 900 RPM cat ii
Providing 2.5mm.thick laminated acrylic sheet to cover
the fan hook or Fan box.
Supplying & erecting approved make low noise
decorative exhaust fan having square frame ABS body
with inbuilt lowers & square frame.250mm with
Supplying & erecting approved make Digital time
switch having lithium cell 6 years operative and operate
battery backup 1 channel day clock with 14 memory
programme, suitable to operate on 240V + 5%, 16A
with, floating contacts Minimum switching setup time
minimum & LCD display. Also comprised permanent
ON/OFF switching. Programming switches & housed in
fire proof thermoplastic enclosure & transparent cover
erected as required with necessary connection erected as
Supplying & erecting power contactor ,AC3 duty for
373 6.00 time switch complete erected as per direction Cat III (C) each 857.49
4 pole 440V 16 Amp.
Supplying and erecting approved make Octagonal pole
made from HR sheet steel. The pole should be made as
374 65.00 per IS. and shall be coated with hot dip galvanizing as each 8192.11
per IS 2629/2633/4759, suitable suspend local wind
speed with integral Junction box consist of terminal
Item Accoring to
but may be Item Work Unit Tender Rates
plate of min 6mm Hylam sheet, standard profile
35mmX7.5mm Din-Rail for MCB Mounting, stud type
terminal and arrangement for cable termination to be
erected With Suitable foundation (Included) as per
details given by manufacturer considering site
(D) 6 Mtr. Long 70 mm Top X 135 mm bottom dia,
mm thickness with 200mmX200mmX12mm base plate,
4-M20 Bolts and 600mm long with necessary G.I. J
Bolts .Approx Pole weight 59 kg
Providing and erecting street light pole bracket
comprising main B Class GI pipe of 4.2 cm/require
outside dia. complete with suitable B Class G.I sleeve
tubing of approx. 45cms.length and suitable for 76.5 mm
/ 80mm. / require size pole top having sufficient
fasteners for fixing the brackets and having spread of
mtr. length with suitable rise as per site condition &
suitable welded stiffener reducer and nipple with check
nut complete painted with one coat of Red oxide / PU
base primer and two coats of Aluminium / PU paint.
paint with following nos of arms.
[A] Single Arm bracket 1 Mtr
376 32.00 [B] Double Arm Bracket 1 Mtr each 829.21
Painting of street light pole with bracket complete with
377 65.00 two coats of Aluminium paint for following size of pole. each 265.63
(B) up to 6 mtr.
Supplying and erecting Direct On-line Electronics
Starter with 2-5/4-10/8-14/10-16 Amp. Rating relay
(variable current setting) directly operated in totally
insulated elegant enclosure and 18 Amp. Rating power
relay with start - stop button for single phase operation
up to 3 HP as per complete erected on P.W. Block with
following features. Low voltage cut off below 140 V
High voltage cut off above 280 V Overload protection
Indicating LEDs for motor on lv, hv & overload
tripping. [Cat.II]
Supplying and erecting push button operated fully
automatic Star-Delta starter with 3 Nos. of 15A.rating
contactors and directly operated thermal overload relay
379 6.00 having 10-21A range and erected in sheet steel each 9758.62
enclosure for 3 phase 415V. 50 c/s. A.C. motors from
7.5 to 15H.P. complete erected on (A) P.W. Block with
necessary connection. Cat.III
Supplying and erecting push button operated fully
automatic Star-Delta starter with 3 Nos. of 15A.rating
contactors and directly operated thermal overload relay
380 6.00 having 10-21A range and erected in sheet steel each 184.83
enclosure for 3 phase 415V. 50 c/s. A.C. motors from
7.5 to 15H.P. complete erected on (B) Angle iron frame
add to the above
Providing & erecting motor protection circuit breaker
with shock proof enclosure (IP 65) erected as per
direction for following motor HP 3 phase 440V A.C.
[B] up to 7.5 HP / 10 HP 12 to 18 Amp.
382 27.00 Supplying and erecting approved make suitable panel each 43.43
Item Accoring to
but may be Item Work Unit Tender Rates
indicator LED type lamp, lens cover, complete erected
with necessary connections.
[D] For 5 HP 3 phase open well horizontal mono block
383 4.00 pump set suitable for 1350 LPM to 310 LPM @ 10 to 42 each 18746.61
Mtr head suitable for 50/65 mm dia delivery pipe
S.I.T.C. of single phase submersible pump set suitable
for 100 mm size or more dia bore well having motor
capacity and discharge as under with necessary panel
384 1.00 box. Lifting and Lowering taken extra.(a) Motor rating 1 each 15595.41
HP (12 stage) pump having capacity of 50 LPM at 43 to
45 mtr head suitable for 32 mm dia. delivery pipe
Providing and erecting ISI marked PVC insulated PVC
Sheathed Flat flexible Submersible copper cable
approved make of following Size. (B) 3 Core x 2.5 Sq.
Providing Water proof straight Joint in PVC insulated
flat flexible copper cable by using insulating material,
water proofing material, & making the joint complete.
Supplying of following size of STANDARD UPVC
column pipe with coupler and wire lock [B] 32 mm dia
Providing, and erecting 11 KV D.P. 9 mtr. high
Structure made of 6" x 3" ‘I’-Section Girder, 4" x
2"channels, clamps, nuts, bolts etc. Suitable for erection
of the followings duly connected with necessary ACSR
conductors. as per drawing approved by the Engineer- in
charge complete with following. Height as per IS 7 Mtr
(A) 11 KV 200 Amps Drop out fuses with S.R.B.P.
tubes carries.-Three nos
(B) 11 KV G.O.D. switch complete with insulators,
operating handle with galvanised pipe, Sq.bar etc.
(C) 11 KV lightening arrestor with clamp- Three Nos.
D) 11 KV shackle insulators- Six Nos.
(E) The above D.P. structure should be earthed with
mm.X 3 mm thick double copper earth strips run
separately and connected with separate copper plate
earth electrode.
Supply of 500 KVA Outdoor type Compact Substation
consisting of Transformer,HT switchgear and LT
Switchgear and confirming to IEC-62227. a)
Transformer: 500 KVA Copper wound 11KV /433 V
DYn11, Dry Cast resin type Transformer with tapping
range +10 to -10% @ 2.5% ( with tolerance), class F
with surge restorers, Digital WTI, IS1171 as per b) HT
389 1.00 Compartment: 11KV, 21kA for 3 Sec . 630 A 50 Hz, each 1666508.08
gas insulated VCB in SS tank in sheet enclosure having
provision for one no. direct connection of Incoming
supply cable upto 300sq mm and one no. VCB(
Manually charging & closing) in series with LBS
between VCB and Transformer, Self Powered Relay
O/C +1 E/F Relay type CSPR-V5, mechanical
ON/OFF indicator, trip coil , Manual Close & Trip PB,
Item Accoring to
but may be Item Work Unit Tender Rates
live cable indicator, mechanical interlocks, pad locking
facility, SF6 gas manometer, cable boots, 3 nos. CTs
with Ratio -/1A, Cl: 5P10, 2.5 VA for protection c) LV
side compartment : one no. ACB of 800A, 50kA, 4Pole,
Microprocessor based release with arrangement for
bottom cable termination (100% for phase & 50% for N,
Current density - 1A/ sq mm) The enclosure should be
of IK10 type.The Enclosure shall construction shall be
GI of thickness at least 1.6/2mm.The enclosure shall be
Powder Coated. Each compartment will be provided
with the door and pad locking arrangement. The
Compartment illumination lamp with door operated
switch shall be provided for each compartment. The
Transformer compartment will have IP-34 ingress
protection, whereas the HT/LT compartment will have
IP-54 protection.The connection between HT and
Transformer shall be by 3 runs of single core 95 sq mm
XLPE aluminium cable and between Transformer to LT
switchgear shall be appropriate rating Aluminium PVC
sleeved Busbar Add extra Rs 9000/- for integrated steel
cubical panel IP 54 to house upto 03 Nos additional
outgoing switchgears with proper rating busbar
drop,supports etc with arrangment for cable termination
etc. (Switchgears is not included in this)
Add extra Rs 16000/- for integrated steel cubical panel
IP 54 to house upto 06 Nos additional outgoing
switchgears with proper rating busbar drop,supports etc
with arrangment for cable termination etc.( Switchgears
is not included in this) Tap of Units
a) Plug in boxes will be draw out type, contacts shall be
silver plated and spring loaded.
b) The front operating handle will be interlocked with
the plug-in boxes cover so that MCCB can be operated
only with suitable cover in close position.
c) The door shall be provided with the door knobs.
d) When the MCCB is in ‘ON’’ position, even with the
door knobs unlocked, the operator should not be able to
remove the box or open the tap off location cover.
e) During insertion, the earth conductor shall make
contact first before the phase conductors. This should
follow the sequence of first in last out concept.
f) When the box is open the live conductors shall be safe
guarded by a transparent insulator plate which allows for
visible inspection but does not allow touching of the live
(A) Aluminium Bus (e)1250 Amp. Capacity
Providing and erecting sandwiched type bus duct having
following specification : Sandwich type busbar for use
as Feeder Busbar for interconnection between separate
electrical equipment/ load centers, and for use as Plug in
390 35.00 busbar risers. The busbar shall be suitable for operation each 13995.57
in a 690V / 1000 V system with frequency of 50 Hz
.System can be either earthed or unearthed. Impulse
voltage should be 12 KV. Standards: The busbar shall be
designed and manufactured in accordance with the
Item Accoring to
but may be Item Work Unit Tender Rates
following international standards for busbar trunking.
-IS 8623/ 1993 Part I & II : Particular requirements of
busbar trunking System
-IEC 61439 Part I & VI : Particular requirements of
busbar trunking System
-IEC- 60529 : Degree of protection TESTING
The busbars shall be type tested at a reputable national /
International test laboratory (ASTA or CPRI) for short
circuit withstand. The test shall be for a minimum
duration of one second.
• Degree of ingress protection (IP rating) shall also be
tested at any reputed independent laboratory. This test
shall be for IP 55 for Indoor and IP 65 for Outdoor
• Short circuit and Degree of protection type test reports
will be submitted for vThe bsubars shall be of high
conductivity Copper of 99.9% pure ETP grade and high
conductivity Aluminium of 99.59% pure 19501 grade.
Where as earth conductor is required, it shall be separate
external earth conductor, of high conductivity
aluminium. Cross section of Earth Conductor shall be as
per IEC 60439. It should be possible to provide a 200%
Neutral where specified. Phase cross over box should
have busbars crossing over each other not cables.
The busbars shall be individually insulated with 2 layers
of insulating film. Layers of POLYSTER material class
‘F’, 155ºC. The housing shall be made of 1.6 mm
electrogalvanised sheet steel, with an epoxy powder
coated paint finish of RAL 7032 grade. Alternatively
Aluminum casing of 2.5mm may also be provided. The
housings shall be profiled, to provide higher strength
and efficient heat dissipation. The width of the housings
shall be same for all ratings of busbars, in order to
provide interchangeability of tap off boxes.
The joints between sections shall be made so as to
provide flexibility during installation and expansion /
contraction of busbar during operation. The joints shall
be of the single bolt type. The joint construction must
have the following features.
a) Thermal expansion of Busbars at joint of at least
b) The joint insulation must be of one piece moulded
design and not have any cut edges which can absorb
c) Joint assembly shall be removable as separate sub-
assembly so that it can be inserted or removed without
disturbing the adjacent sections.
d) The joint system must be designed in a way that the
installer cannot insert the busduct length too far and
damage the bolt insulator.
e) The busbars ends shall not have any holes or slots at
the joints – the electrical continuity shall be through
pressure plates, achieving a high area of joint cross
section and expansion capability.
391 18.00 Providing and fixing printed instruction chart both in each 130.29
Item Accoring to
but may be Item Work Unit Tender Rates
English and Gujarati and duly framed with front glasses,
for treatment of person suffering from Electric shock
with minimum 50" diagonally size.
Providing pair of rubber hand gloves suitable for
working on 11 KV/22 KV supply.
Supplying rubber matting of following thickness as per
IS:15652/IEC 61111 (c)12mm
Supplying stand first AID box with antiseptic cream,
medicine for use on wounds due burn, crepe bandage,
gauge bandage, medicated ready to use bandage (Band-
aid) adhesive tape for medicinal user, Scissors, anti-
septic solution (Savlon or similar) etc. (All above
contents shall be of standard makes)
Providing and erecting ISI Marked 3core 240 Sq.mm
XLPE insulated 11 KV armoured cable Aluminium
395 150.00 conductor IS-7098 to be laid on wall with clamps or in Mtr 2217.96
provided cable trench / pipe approved manner as
Supplying and erecting high tension cable end box
396 5.00 outdoor type suitable. for 11 KV 240Sq.mm 3core H.T. Mtr 4195.54
cable complete with gland bushing and jointing material.
Supplying and erecting, commissioning and testing of
Diesel Generating set confirming to IS: 4722:1968 &
BS:5514 having continuous rating, 3 phase, 415 volts,
50 cycles A.C. supply comprising of a totally enclosed
air/water cooled diesel engine with multi-cylinders
developing suitable BHP not less than following
capacity at 1500 RPM with 10% overload for one hour
in 24 hours with standard accessories like fly wheel,
lubricating oil cooler, "A" class governor, heavy duty
fuel wheel and lubricating oil filter, oil bath air filler,
lubricating oil pressure gauge, end exhaust manifold,
standard set of tools with adjustable spanners, screw
drivers, cylinder head to cover, joint cylinder head to
exhaust, element lube oil filter, 12 / 24 volts electric
starting equipment complete with standard heavy duty
battery, dynamo, cut-outs, ammeter, necessary wiring,
pressure gauge, starter etc and heavy duty Residential
type exhaust silencer (With DEF System) and vertical
hot air duct both logged with asbestos rope, save oil
trays, exhaust piping of required length, standard
wall/floor mounted fuel with level indicator and piping
and drip proof alternator, self excited, self regulated,
screen protected, with excitation system, capable of
delivering the rated system output at 415 volts, 3 phase,
0.8 PF, 50 Hz, 4 wire, running at 1500 RPM,
conforming to IS-4722- 1968 with voltage regulation
+/- 5% of rated voltage from no load to full load. Both
the engine and alternator fitted on a common fabricated
steel base plate with antivibration mounting engine
and alternator both connected to each other by flexible
flange coupling and with floor/wall mounted control
panel box comprising of voltmeter ammeter, selector
switches, ACB / MCCB / MCB of adequate capacity,
indicator lamps duly wired with HRC fuses. The
Item Accoring to
but may be Item Work Unit Tender Rates
alternator & control panel shall be connected with
provided suitable capacity armoured cable and complete
with Acoustic enclosure (canopy) made out of 16 SWG
CRCA Sheet, sound absorbing material Rockwool of
density & 100 mm thick conforming to IS:8183 / PU
Foam of 40 Density - at least 40 mm. The resin bonded
rockwool covered from inside the canopy by perforated
sheet with 3/4 mm holes, sound level not more than
dB at a distance of 1 mtr, as per PVCT norms.DG set
should have in built fuel tank capacity of minimum 8 hrs
of continous running capacity on full load . Erection,
commissioning and satisfactory testing as per
requirement with first filling of fuel (minimum up to the
80% of fuel tank capacity), oil, etc. with guarantee /
Warrantee of complete system for Two years. & with
obtaining all necessary certificate from Electrical
Inspector. The Capacity and Ratings of DG sets are as
below. (As per new CPCB4+ Emission norms Engine
With - Turbo Charger, EGR (Exhaust Gas
Recirculation), CRS (Common Rail Fuel System), DOC
(Diesel Oxidation Catalyst), SCR (Selective Catalytic
Reduction), Integrated wiring harness connected to
(P) Continuous rating of 180 KVA ,BHP not less than
Providing & erecting approved make AMF control panel
suitable for following size of 3 phase, 415 V., 50 cycles,
A.C. diesel generating set complete of scope as detailed
1) Power module: A pair of electromechanically
interlocked contactors (for mains & generator)
Overload relay for generator contactor Neutral contactor
for mains and generator Power socket for connections.
2) Control and metering module: Line voltage monitor.
Generator voltage monitor Ammeter 3 items attempt
start facility. Air circuit breakers/MCB/MCCB of
suitable rating for auto/manual operation. Auto/manual
switch. Emergency stop push buttons. Manual start push
button. frequency meter. Engine hour meter. Two
earthing studs.
3) Protection module: The engine shutdown in the
unlikely event of Low lube oil pressure High cylinder
head temperature. V belt failure.
4) Indicators with alarm Load on generator.
5) Indicators Load on mains Engine fails to start .
Emergency stop battery charger. The AMF Panel of
following capacity
(D) AMF Control Panel for200 KVA/250 KVA3 phase
Supplying and erecting Acoustic enclosure (canopy)
made out of 18 SWG, CRCA Sheet, sound absorbing
material Rockwool of 64 density & 100 mm thick
conforming to IS:8183 The resin bonded Rockwool /
PU FOAM covered from inside level not more than
dB at a distance of 1 mtr, as PVCT norms , on provided
Item Accoring to
but may be Item Work Unit Tender Rates
foundation suitable for following size of DG Set. The
enclosures for following capacity of DG sets.
(E) For for 160/180/200/250 KVA
Design, Supplying, installing, testing of factory
fabricated ready made Three phase APFC Panel Cubical
Panel fabrication should be type tested as per IEC
61921, 61439:1&2 Capacitor Duty Contactor for
switching as per following Steps Incomer Switch of
MCCB type Icu=Ics=50KA at 400/440 Volts, with OC,
SC, internal earth fault protection Incomer Switch of
MCCB type Icu=Ics=50KA at 400/440 Volts, with OC,
SC, internal earth fault protection,Copper tinned
insulated Busbar,Cubical panel should be indoor type
with IP 43 and IK 10,Metalized polypropylene film
tye3-phase 550Volt Capacitor,De tuning Reactor for
each capacitor,Panel having Short Circuit and Overload
protection,Each step Capacitor having suitable MCB
with Sc, OL, internal earth fault relay,Each stage having
Stage Contactor (Capacitor load rating),PF regulator
master controller having suitable steps with LCD
display, Rs 485 Communication port, Indication LED
Lamps for main incomer and ON-OFF for each
capacitor bank,MS Chanel for Floor mounting, Cable
entry as per site situation,Cooling fans for panel
SITC of Vertical Air Termination Solid aluminium with
Base- 10 mm dia and 1000 mm long. Air Termination
Base tested for conditioning, Ageing Test & Lightning
401 2.00 impulse current withstand test: 100 kA of 10/350µs each 9416.23
waveform in an accredited Third party laboratory as per
6.3 & 6.4 of IEC 62561-1 2017 protocol with MAST
34mm dia 3000 mm long- Cold Galvanized
SITC of 8 mm dia solid Aluminium Conductor for roof
top mesh grid and tested as per IEC 62561-
conducted in the Govt. accredited thirty party laboratory
to meet the requirement of IS/IEC 62305 with Required
Accessories - Aluminium Holding clamp at every 1 mtr
distance, Aluminium/SS cross splicer at every crossing
of Alu. conductor, Expansion piece with connectors at
402 985.00 every 20 mtr distance, Aluminium straight Splicer to Mtr 299.97
connect conductors. All Accessories should be tested as
per IEC 62561-1 2018 Cl. 6.3 for conditioning &
Ageing Test & 6.4 for Lightning impulse current
withstand test: 100 kA of 10/350µs waveform(Ageing &
Electrical test ) conducted in a sequence manner &
tested in the Govt. accredited Third party laboratory to
meet the requirements of IS/IEC
SITC of Galvanized Steel Flat 25x6 mm thickness from
earth electrode directly in ground as required. Zinc
403 150.00 coating: 500 g/m square (Approx:70 micron coating) each 154.53
tested and used exclusively for lightning protection
earthing system and ring equipotential bonding.
SITC of 14.2 mm dia 3 mtr long Earth electrode of High
404 30.00 tensile steel electrode with 250 micron copper bonding each 5992.33
& 1 bag of Carbon fill Based environment friendly
Item Accoring to
but may be Item Work Unit Tender Rates
backfill tested as per IEC 62561-7 in NABL accredited
Laboratory and suitable stainless Steel double sided
clamp. Eco Friendly rust proof heavy duty weather proof
Polyethylene Earth Pit Chamber with following
dimensions :254 mm dia (top), 330 mm dia (bottom) &
260 mm (height).
Supply, Installation, Testing & Commissioning of
following size of Grid Tied Solar Power Plant with
Solar Panels (ALMM approved): Frame Material :
Anodized Aluminum alloy Frame With Twin Wall
Profile, Front Cover : High Transmission Low-Iron
Tempered Glass (AR Coated), High efficency and
positive power tolerance Pmax: 0/+5, Module Efficiency
should be approx. 18%-21%, Normal operating
temperature 45'C, Junction Box with Waterproof IP67 &
MC4 Compatible and Enclosed with Bypass diodes,
100% Electroluminescence test to ensure error free
Modules, Thep. temp. co-efficient of the PV module
shall equal or better than -0.45%/degree C. Solar PV
modules of minimum fill factor 75% to be used. Unit
Production:- 4 to 5 Unit /kw /day (Actual)(1Year Avg)
With 10 year Product warranty and 25 year Linear
Power Warranty., Solar Inverter: MPPT Range: 80-1000
V, Max efficiency: 97.5% - 98.9%, O/p Frequency:
50/60Hz, Operating Altitude (m) ≤4000, O/p Power
Factor: ~1, O/P THDi: <3%, Operating Tempreture
Range: -25~60°C, Anti-islanding Protection:
ntegrated, Input Reverse Polarity Protection Integrated,
Insulation Resistor Detection Integrated, Residual
Current Monitoring Unit Integrated, Output Over
Current Protection Integrated, Output Short Circuit
Protection Integrated, Output Over Voltage Protection
Integrated, Protection Degree: IP65, User Interface LCD
& APP,Datalogger & Communication: GPRS / Wi-Fi,
Module Mounting Structure: Seamless Box Pipe / 'C'
Channel of suitable size for rooftop solar installations
with good stability agaist wind & weight load., Hot
Dipped Galvanized steel coils. suitable arrangement for
base plate for foundation , solar panel mounting, the
structure should be suitable for carry the load of solar
panel,wiring, sprinkler system etc. with necessary
foundation work/wall mount, j bolt, anchor fastner etc.
the nut bolt used for installtion of stucture should be (SS
304) quality. and Balane of System with necessary
Swithgears (Suitabel size and protection of ACDB &
DCDB), inter connecting wiring, earthing system,
lightining arrester system, all liasoning work with
various gov. dipartment like state nodal
agency,DISCOM & CEIG is included in agency scope
(Excluding GEDA Application fees, Solar connectivity
Charges, Meter connectivity Charges, Meter testing
(E) Grid Tied Solar Power System: 51 - 100 kW (3 -
406 100.00 Providing & erecting Automatic solar panel cleaning per kw 3553.18
Item Accoring to
but may be Item Work Unit Tender Rates
system for solar power projects which includes
necessary plumbing work (UPVC pipes and accessories)
from source of water to project site (upto
meters),Suitable size of sub mercible/ open well motor,
necessary wiring for motor and sprinkler system with
safety, timer circuit for automatically on/off the
sprinkler system, necessary size oand number of
nozzles/JET (minimum 1 Nozzle/Jet per module).
(E) 51KW-100KW Cleaning System
The all inclusive comprehencive annual maintance
contract cost covers yearly maintanance of solar Pv
Modules, Inverter, wiring,earthing,switchgears, etc with
material and labour cost including preventive
maintanance.The cost covers entire installation. AMC
407 100.00 also includes monthly site visit and inspection of project per kw 3852.14
with submission of inspection and solar generation
report. All parts should be replaced/repaired if found
faulty within specified time. Agency has to provide
necessory licening work for warranty ,power,
Bidirectional meter etc (D) 51KW-100KW System
Providing & laying approved make Double walled
corrugated pipes (DWC) of polyethylene(conforming to
IS 14930 II )with necessary connecting accessories of
same material at required depth in existing trench for
laying of cable. below ground / road surface for
enclosing cable
providing and erecting Miniature circuit breaker single
pole 0.5A to 2A system and having breaking capacity
10 KA to be erected in existing box. confirming to IS
8828/1996 with ISI Mark Supply Installation, assembly,
connection, testing and commissioning of Panel as per
Drawing, Specification, Technical Data sheet & IS.Panel
shall be manufactured CPRI approved panel
manufacturer with inhouse 7 tank process and painting
The unit rate for each item shall include
Testing of panels as per specifications at manufacturer's
works in presence of clients representative and/or
Supply & delivery of the panels at the site.
409 65.00 Assembly and wiring of component supplied separately. Nos 270.68
Installation of panels as per lcoation arranged by site
engineer in charge including removing packing.
'Shifting of panels from site store to the suitable
location. (If applicable) Installation of panel in Electric
room or Location suggested by client within campus
including removing packing. Earthing all components,
frame etc. to a common internal earth bar. Supply &
fixing all accessories and supporting structure.
'Toching of body with poweder coating for demaged
parts. All the nuts bolts & joints exposed to the air shall
be covered with suitable anti-oxidant material or as
directed by the Engineer incharge 'Supply & fixing of
100 mm main steel for fixing the panel, alongwith all the
required civil materials required to complete the job as
Item Accoring to
but may be Item Work Unit Tender Rates
per the instruction of engineer incharge.
'To carry out the insulation test at site and all the
readings shall be submitted in duplicate to the consultant
or engineer-in-charge. 'To prepare submission drawing
and to take approval of consultant at each stage.
For panel MS angle stand required. ( Size MS angle &
height of stand as per Panel Weight & size of cable
termination requirement to be calculate by panel vendor,
need to confirm with desing Consultant) Checking of
Internal connection and wiring, operation of switches,
starter, MCCB, MCB, relays, contactors etc.
Supply of necessary tools, hardware, testing hardware,
testing equipment etc. 'To prepare & submit as-built
drawing and handing over document to end user.
'Approval from consultant required before fabrication of
panel. 'Consider Given Rate should be with 5 Years
MLDB ( MAIN LOAD DISTRIBUTION PANEL)
'- AS per Tender SLD drawing (AS PER IEC-61439)
Providing & erecting weather proof, dust & vermin
proof, floor mounted front operated indoor type cubical
panel board necessary IP-42 and above protection as per
approval from engineer incharge made from 14 SWG
thick CRC M.S. sheet for outer body & doors, 16 SWG
thick CRC M.S.sheet for internal partitions with
necessary accesories , supporting angles/ flats channel
including cutting, bending, drilling, welding, riveting
with internal partitions & cable alley as per requirements
& instruction of engineer-in-charge with erection of
(The rates excludes the cost of switchgears, bus bars,
411 45.00 inter connecting mains & Copper Aluminium strips, SQ. MTR. 19387.96
meters, Fuses etc. The dimension shall be measured
excluding base beams) The panel shall be supplied with
following approved manufacturers with following size.
(The rates excludes the cost of switchgears, bus bars,
inter connecting mains & Copper Aluminium strips,
meters, Fuses etc. The dimension shall be measured
excluding base beams) The panel shall be supplied with
following approved manufacturers with following size.
(B) The standard companies switch gear shall be used
and only manufacturers at CPRI approved factory
(ii) with 550 mm. Depth
Providing and erecting Steel cover as per drawing using
16 SWG M.S.sheet of following depth, to house the
switch gear etc. complete with locking arrangement and
412 45.00 lock with duplicate keys per cupboard and door handles SQ. MTR. 4228.87
erected with necessary support and painting. [One coat
red oxide and two coat enamel paint] (A) with angle iron
frame (ii) For 40 cms. Depth
Providing , erecting , fabricating the M.S. structure as
per requirement on site incorporating proper size of M.S.
angles,square,round, flats, bars, channels, sections
complete with cutting, welding, grinding & finishing
duly painted with one coat of red oxide with erection on
site as per direction of engineer in charge with necessary
Item Accoring to
but may be Item Work Unit Tender Rates
grouting, cementing, plastering & finishing complete.
414 150.00 Half / One Module Blanking Plate of Standard Size. Each 9.09
Supplying and erecting triple pole & neutral 440V/
500V panel mounting Aluminium Busbars with four
equal Nos. of bus having current density not more than
0.8 Amp. / sq.mm (Rated current / cross section area)
duly wrapped with colour insulating tape for phase
sequence of following current carrying capacity, erected
with necessary bus bar supports /insulators, main cable
socket to each busbar,erected in existing cubical panel
with necessary connections. (A) Suitable for 100 Amp.
416 75.00 (B) Suitable for 200 Amp. Capacit Rn. Mtr. 1037.27
FIRE HYDRANT SYSTEM (MECHANICAL
FIRE PUMPS, EQUIPMENT, PIPING, VALVES &
GLR/ UG SUMP : GLR/ UG SUMP :Constructing U/G
Sump at ltr capacity Preparing structural design of RCC
Under Ground / Partially under ground / above high
ground level Reservoir of required capacity as per
relevant I.S.s and constructing the same, including
excavation in all types of soil strata (including rock)
including shoring strutting if required, for loose soil / to
protect from collapse due to near by traffic load, casting
100 mm thick P.C.C. leveling course in M-10, Refilling
the pit with proper soil and disposing of the surplus stuff
within a lead of 50 meters. Including cement plaster in
CM 1:3 with approved water proofing compound to
inside water touching surface to container. Including all
types of labour and material charges of lowering, laying,
erecting / hosting and jointing of pipe assembly to inlet,
outlet overflow, washout and bye pass arrangement as
per hydraulic design. Providing and fixing accessories
like MS / GI Ladder, CI Manhole frame and cover,
water level indicator, adequate cowl type ventilators or
lantern type ventilator with stainless steel jail.
B.B. Masonry chambers for valves. Providing and
applying three coats of cement paint / snowcem to the
out side face of structure. It also includes satisfactory
water tightness test as per relevant I.S. code and painting
name of scheme and capacity on the tank as per
direction of engineer in charge. List of Indian Standards
for Design of GSR / SUMP:- The structural design of
GSR shall be in accordance with provisions relevant I.S.
(1) I.S. 3370, Part – 1 to 4, 1965 or latest revised.
(2) I.S. 456 – 2000 or latest revised.
(3) I.S. 1893 – 2000 – 1984 or latest revised.
4) I.S. 875, Part – 1 to 3, 1987 or latest revised.
General Specifications:- The minimum concrete grade
for RCC shall be M-30. TMT Fe 500 grade reinforcing
bars confirming to I.S. 1786 / 1139 shall be considered
in design. TMT bars shall be provided. Any other steel
can be used with approval of C.E. in situation of non
availability in market without extra cost.
Item Accoring to
but may be Item Work Unit Tender Rates
Minimum size (or thickness) of various components
shall be provided as per I.S. Standard. practice of
G.W.S.S.B. Minimum dimensions specified for various
components in tender data / specifications shall be
provided without fail. The safe bearing capacity (SBC)
shall be referred from SBC test report. If poor soil is
found / water table is met with during excavation SBC
shall be scientifically ascertained and design shall be
revise. No extra shall be paid for increase in quantity.
CI pipes and special shall only be used if type is not
specified in tender. When capacity of GSR / Sump is >
20 lakh liters two or suitable compartments acceptable to
executive engineer shall be designed and provided.
Constructing U/G Sump at 1.80 lac ltr capacity.
Without Water Table
Capacty of GSR /Sump
Supplying, Installation, Testing and commissioning of
Electrical motor driven main fire Hydrant pump of
horizontal centrifugal end suction back pull out type
with Mechanical seal ( confirming to TAC & IS
Standards) and capable to deliver 137 M3/hr at
MWC. The pump shall be coupled to TEFC motor of
suitable HP with speed of 2900 RPM ,IEE 2and
complete set shall mounted on common base frame. The
quoted rate shall includes providing & fixing of
419 2.00 coupling, coupling guard, and Foundation bolts & nuts Nos. 233815.00
etc. As per attached specification, vendor to supervise
& co -ordinate with civil agency for pump foundation as
per requirements pump manufacturer & standards. Pump
to equipped with anti vibration pads. Pump to equipped
with anti vibration pads. Pump shifting ,leading, lifting,
positioning included. A) Above pump shall be capable
of furnishing not less than 150% of rated discharge
capacity at a head of not less than 65% of the rated head.
The shut -off head shall not exceed 120% of rated head.
Supplying, Installation, Testing and commissioning of
Electrical motor driven Jockey pump of horizontal
centrifugal end suction back pull out type with
Mechanical seal ( confirming to TAC & IS Standards)
and capable to deliver 10.8 M3/hr at 70 MWC. The
pump shall be coupled to TEFC motor of suitable HP
with speed of 2900 RPM ,IEE 2and complete set shall
mounted on common base frame. The quoted rate shall
includes providing & fixing of coupling, coupling guard,
and Foundation bolts & nuts etc. As per attached
specification, vendor to supervise & co -ordinate with
civil agency for pump foundation as per requirements
pump manufacturer & standards. Pump to equipped
with anti vibration pads. Pump to equipped with anti
vibration pads. Pump shifting ,leading, lifting,
positioning included
Supplying, Installation, Testing and commissioning of
Diesel motor driven main fire pump of horizontal
centrifugal end suction back pull out type with
Mechanical seal ( confirming to TAC & IS Standards)
Item Accoring to
but may be Item Work Unit Tender Rates
and capable to deliver The pump shall be coupled to
TEFC motor of suitable HP with speed of 3000RPM
,IEE 2and complete set shall mounted on common base
frame. The quoted rate shall includes providing & fixing
of coupling, coupling guard, and Foundation bolts &
nuts etc. As per attached specification, vendor to
supervise & co -ordinate with civil agency for pump
foundation as per requirements pump manufacturer &
standards. Pump to equipped with anti vibration pads.
Pump to equipped with anti vibration pads. Pump
shifting ,leading, lifting, positioning included.
Supplying, Installation, Testing and commissioning of
G.I class "C" E.R.W pipes (as per IS:1239 / 3589 )
along with required all pipe fittings and accessories like
sockets, elbows, tees, flanges, gasket, reducers, nut-
422 12.00 bolts, U-bolt/Clamp, anchorfastner, plugs, nipples etc Rmt. 3201.70
complete as specified in technical datasheet.(Including:
10% of all the welded joints shall be done radio
graphically tested and 50% of the joints radiographer
shall be the "Field Joints") 200 mm dia.
Supplying, Installation, Testing and commissioning of
Cast Iron body , Nitrile liner , SS Upper Lower stem,
Teflon bushing RISING TYPE SLUICE VALVE at
PN 16 rating as per IS : 13095 complete with matching
flanges bolt, nut, washer and other fittings accessories.
Supplying, Installation, Testing and commissioning of
CIDF Non return valve, Gun metal internals, Rubber
430 3.00 sealed conforming to IS : 5312 (Part-1), Swing type PN Nos. 7211.40
1.6 rating with matching flanges bolt, nut and washer for
pump house equipment. 150 mm dia.
Supplying, Installation, Testing and commissioning of
CI STRAINER with SS 304 Perforated sheet or screen
with matching flanges bolt, nut and washer for pump
house equipment. 150 mm dia. "Y"- Type
Supplying, Installation, Testing and commissioning of
Gunmetal body IS: 318 LTB‐2, ball type 25mm BSPT
fitting Air Release valve (ARV) with Isolation ball
Supplying, Installation, Testing and commissioning of
Gun metal body, spring type 25mm dia Pressure
Release valve (PRV) with isolation ball valve
(Calibrated at 8 Kg/Cm2)
Supplying, Installation, Testing and commissioning of
436 12.00 Bourdon type, glycerine filled 100mm dial ( Range at Nos. 2727.00
200 psi (16 bar), 304 stainless steel with vent plug and
Item Accoring to
but may be Item Work Unit Tender Rates
polished stainless steel bayonet ring. Suitable for liquid
filling. Welded case/ socket connection) pressure
gauges having 15mm NPT fittings with all accessories
like isolation valve, bush etc.
Supplying, Installation, Testing and commissioning of
Pressure switch of approved make in pipe line suitable
for line presure up 15kg/cm2 & including connection
437 5.00 with main panel etc. as required complete in all respects Nos. 3787.50
for Hydrant, Sprinkler, Standby and Jockey pump
including necessary wiring upto control panel & other
Supply and Installation of MS steel for supports in pump
438 500.00 room for the supporting of valves, header, MCC panel Kg 202.00
and fuel tank etc.
Supply and Applying of Painting on pipe lines,
equipments and valves like Strainer, NRV, side pump
room with two coats of enamel paint (As per the IS:5,Sr
No: 79,ISC no-536) over one coats of Red oxide primer.
Supplying, Installation, Testing and commissioning of
air vessel of size (400NB dia x2000MM long ) complete
with drain, bottom tapping and top cap with air release
valve and pressure release valve
HYDRANT NETWORK Supplying, Installation,
Testing and commissioning of G.I class "C" E.R.W
pipes (as per IS:1239 / 3589 ) along with required all
pipe fittings like sockets, elbows, tees, flanges, gasket,
reducers, nut-bolts, U-bolt/Clamp, anchorfastner, plugs,
nipples etc complete as specified in technical datasheet.
(Including: 10 % of all the welded joints shall be done
441 250.00 radiographically tested and 50% of the joints Rmt. 2393.70
radiographed shall be the "Field Joints") Rates must be
included with following job : Pipes: All pipe fittings
shall be as per IS: 1239 P-1and2, fittings below 50mm
should be heavy ducty socket weld. Rediography: 10%
of total field joint. Holiday (wrapping coating) Testing:
100% U/G line Phase wise hydro testing at 11.2Kg/
Cm2 for 3 to 4 Hours 150 mm dia.
Supply and Apply of Anti Corrosive Treatment for
underground pipe with primer and one coat of 4 mm
minimum thick anti corrosive tape with black mastic
paint after heating procedure.
Supply and Apply of Painting for aboveground lines
with two coats of enamel paint (As per the IS:5,Sr No:
79,ISC no-536) over one coats of Red oxide primer for
above ground pipe line network.
Supplying, Installation, Testing and commissioning of
Cast Iron body , Nitrile liner , SS Upper Lower stem,
446 7.00 Teflon bushing Butterfly valve at PN 16 rating as per IS Nos. 7211.40
: 13095 complete with matching flanges bolt, nut,
washer and other fittings accessories. 150mm Dia
448 4.00 Supplying, Installation, Testing and commissioning of Nos. 4090.50
Item Accoring to
but may be Item Work Unit Tender Rates
Gunmetal body IS: 318 LTB‐2, ball type 25mm BSPT
fitting Air Release valve (ARV) with Isolation ball
Supplying, Installation, Testing and commissioning of
SS made Hydrant Valve as per IS:5290, Type-A Single
headed, 63 mm dia complete with matching flange and
fitting accessories.
Supply and Installation of SS Branch pipe with nozzle
Supplying, Installation, Testing and commissioning of
Fire hose pipe, RRL, Type-A, as per IS:636, 63mm dia
x 15 Mtr. long, complete with SS male and female
instantaneous coupling.
Supplying, Installation, Testing and commissioning of
MS Hose box to accommodate 2 lengths of hose pipes
452 23.00 of 15 Mtr. Long and 1 No of branch pipe with front Nos. 5888.30
openable glass door and glass for key complete with all
fittings and accessories.
Supplying, Installation, Testing and commissioning of
453 2.00 way fire brigade inlet with CI body and GM coupling Set 9241.50
built in NRV complete with all fittings and accessories
Supply, fabrication,erection of MS steel for supports of
fire hydrant network for T support of RCC block, hose
box frame, and other surface supports for fire fighting
Supply and installation of First Aid fire hose reel of
25mm bore size, Gunmetal IS:318 LTB2/ SS 304 Gr. I.
Type -II, Complete with MS drum and GM shutoff
FIRE SPRINKLER SYSTEM Supplying, Installation,
Testing and commissioning of G.I class "C" E.R.W
pipes (as per IS:1239 / 3589 ) along with required all
pipe fittings like sockets, elbows, tees, flanges, gasket,
456 56.00 reducers, nut-bolts, U-bolt/Clamp, anchorfastner, plugs, Rmt 1717.00
nipples etc complete as specified in technical datasheet.
(Including: 10 % of all the welded joints shall be done
radiographically tested and 50% of the joints
radiographed shall be the "Field Joints") 100mm dia.
Supplying, Installation, Testing and commissioning of
Heavy lever operated butterfly valve, at PN
complete with matching flanges bolt, nut and washer.
Supplying, Installation, Testing and commissioning of
463 16.00 Drain Assembly with isolation valve of 32mm dia ball Set 2470.46
Supplying, Installation, Testing and commissioning of
464 1000.00 MS steel for supports for main sprinkler header, Kg 252.50
distribution line, branch pipe and arm pipes.
465 698.00 Supply, apply of Painting of aboveground lines with two Rmt. 323.20
Item Accoring to
but may be Item Work Unit Tender Rates
coats of enamel paint over & one coats of Red oxide
primer for above ground pipe line network. (Fire red
color, Shed No 536 / IS:5)
Supplying, Installation, Testing and commissioning of
466 600.00 Fire sprinkler nozzle @ 68 degree temp. rating standard Nos. 757.50
responce Pendent type (K-5.6) .
Supplying, Installation, Testing and commissioning of
SS flexidrop of appropriate length 700 mm long
CIVIL PART Excavation and back Filling for
470 9.72 following soil condition for underground fire line of 1.2 M3 222.20
Mtr deep from the ground level. Soft soil
471 3.00 Hard Soil /rock soil M3 119.18
Supply and making PCC pedestal blocks for above
ground pipe line network dully grouted 600mm below
the ground level and 300mm above ground level of size
300mm wide with grouted- ISMC 100 x 50 x 6mm to
clamp the pipe line on the block. (MS steel quantity is
given in separate line items)
Making of Core Cutting with various slab height for
fire riser 150NB
ELETRICAL AND INSTRUMENTATION PART
CONTROL PANEL FOR PUMPS Supplying,
Installation, Testing and commissioning of Motor
control center for above mentioned Electrical pump (1
Nos), Sprinkler pump (1 Nos) and jockey pump (1
Nos),Diesel Pump (1Nos) and complete with incomer,
Star delta starter, protective fuses, indicating lamps with
interlock facility with top/ bottom entry with foot
mounting type complete with all accessories. Separate
cabinet for diesel engine pump having battery charger
with start, stop, accept, and test push button (for 1 sets of
DG pumps) . All the components shall be housed in a
common cubical made of 16 swg. M.S. sheet with
required stiffeners ( if required).The panel shall be
powder coated of approved colour both inside & outside.
The panel shall have both bottom & top cable entry
provisions and panel shall be mounted on Pedestal of
300 mm height. including 1 coat Corrosion resistance &
two coats of red enamel paint complete. Including MS
Base frame, Soft Starter for Main Pump, Local Hooter
for Alarm. MCC panel should have following
mechanisum for pumps, (a) Jockey Pump: Auto start -
Auto stop, (b) Main Pump : Auto Start - Manual Stop,
(C) DG pump - Manual Start - Stop.
Supplying, Installation, Testing and commissioning of
Cabling and earthing From control panel to main pumps
-1 nos , Jockey pumps- 1 nos , pressure switches, from
DG control panel to DG pump local panel for controls
and battery charger with 25 x 3mm thick GI strip for
double earthing of the panel and motor.
Item Accoring to
but may be Item Work Unit Tender Rates
FIRE EXTINGUISHER & ACCESSORIES: FIRE
EXTINGUISHERS Supplying, Installation, Testing
478 36.00 and commissioning of ABC Dry Powder type - 6Kg. Nos 2929.00
capacity as per IS:15683 (complete with zebra painting -
Supplying, Installation, Testing and commissioning of
479 36.00 CO2 type - 4.5Kg. capacity as per IS:15683 (complete Nos 5504.50
with zebra painting - on background)
Supplying, Installation, Testing and commissioning of
safety and emergency escape signages board.
Supplying, Installation, Testing and commissioning of
481 8.00 fire bucket complete with canopy (4 bucket with stand Set 11110.00
FIRE ALARM AND DETECTION SYSTEM
482 2.00 Supplying, Installation, Testing and commissioning of 4 Set 11150.40
loop Conventional fire alarm/detection control panel.
Supplying, Installation, Testing and commissioning of
Photoelectric smoke detector Complete with LED,
complete with Mounting Base Complete as required
Conforming to IS.
Supplying, Installation, Testing and commissioning of
Photoelectric Heat detector Complete with LED,
complete with Mounting Base Complete as required
Conforming to IS.
Supplying, Installation, Testing and commissioning of
485 33.00 Hooter complete with Mounting Base as required Nos 4125.85
conforming to IS
Supplying, Installation, Testing and commissioning of
Conventional Type Manual Call Point having Surface
or flush mounting Option Complete as required
conforming to IS Standards
Supply & Laying of 2core, 1.5 sq. mm. stranded copper
487 2500.00 conductor, pvc insulated PVC sheathed, aluminum Mtrs. 131.30
myler tape shielded FRLS wire
Supply & installation of Mounting Base, DC
488 1.00 gland,Hood, Junction boxes, saddle, and other cable Lot 25330.80
Supply Installation, Testing & Commissioning of
modular type Variable Refrigerant Volume air cooled
Outdoor units suitable for cooling and heating, having
all hermetically sealed inverter type Scroll
Compressor(s), microprocessor based Controller, top
discharge type condensing unit(s), with R410 A
Refrigerant (Or Eco Friendly Green Gas if any),
vibration isolators, with suitable foundation, MS Stand
for Unit with necessary paint etc. complete as required.
The unit shall deliver the rated capacity at AHRI
Conditions and work even at 50°C ambient temperature
without tripping. The unit shall be suitable to work on
400V +/- 10%, 3 Phase, 50Hz AC power supply. The
unit shall be filled with first charge of the refrigerant and
ready for use as required. The COP at AHRI conditions
shall not be less than 3.1 and IEER not less than
6.5. (Design should be got approval before execution
from engineer in charge)
Item Accoring to
but may be Item Work Unit Tender Rates
Supply, installation, testing and commissioning of
following minimum capacity 4-way/2 way/radial flow
as per approval VRV Cassette Type Indoor ceiling
mounted unit equipped with synthetic washable media
pre-filter, fan section with low noise fan/dynamically
balanced blower, multispeed motor, coil section with
DX Copper coil, electronic expansion valve, outer
cabinet, drain pump, grill, necessary supports, vibration
isolation, cord less remote control etc., suitable for
operation on single phase 230 V ± 10%, 50Hz AC
supply, max noise level 60dB @ 400 cfm per
TR(minimum) complete, as required. The unit shall have
automatic force shut down provision in case of fire on
receiving signal from BMS System. The cooling
capacity of indoor unit will be at air inlet conditions of
27 Degree C DB and 19 Degree C WB temperature fresh
air provision compatible for Remote Operation System
Supply, installation, testing and commissioning of
following minimum capacity 4-way/2 way/radial flow
as per approval VRV Cassette Type Indoor ceiling
mounted unit equipped with synthetic washable media
pre-filter, fan section with low noise fan/dynamically
balanced blower, multispeed motor, coil section with
DX Copper coil, electronic expansion valve, outer
cabinet, drain pump, grill, necessary supports, vibration
isolation, cord less remote control etc., suitable for
operation on single phase 230 V ± 10%, 50Hz AC
supply, max noise level 60dB @ 400 cfm per
TR(minimum) complete, as required. The unit shall have
automatic force shut down provision in case of fire on
receiving signal from BMS System. The cooling
capacity of indoor unit will be at air inlet conditions of
27 Degree C DB and 19 Degree C WB temperature fresh
air provision compatible for Remote Operation System
Supply, installation, testing and commissioning of
following minimum capacity 4-way/2 way/radial flow
as per approval VRV Cassette Type Indoor ceiling
mounted unit equipped with synthetic washable media
pre-filter, fan section with low noise fan/dynamically
balanced blower, multispeed motor, coil section with
DX Copper coil, electronic expansion valve, outer
cabinet, drain pump, grill, necessary supports, vibration
isolation, cord less remote control etc., suitable for
operation on single phase 230 V ± 10%, 50Hz AC
supply, max noise level 60dB @ 400 cfm per
TR(minimum) complete, as required. The unit shall have
automatic force shut down provision in case of fire on
receiving signal from BMS System. The cooling
capacity of indoor unit will be at air inlet conditions of
27 Degree C DB and 19 Degree C WB temperature fresh
air provision compatible for Remote Operation System
493 43.00 Supply, installation, testing and commissioning of Nos. 29626.33
Item Accoring to
but may be Item Work Unit Tender Rates
following minimum capacity 4-way/2 way/radial flow
as per approval VRV Cassette Type Indoor ceiling
mounted unit equipped with synthetic washable media
pre-filter, fan section with low noise fan/dynamically
balanced blower, multispeed motor, coil section with
DX Copper coil, electronic expansion valve, outer
cabinet, drain pump, grill, necessary supports, vibration
isolation, cord less remote control etc., suitable for
operation on single phase 230 V ± 10%, 50Hz AC
supply, max noise level 60dB @ 400 cfm per
TR(minimum) complete, as required. The unit shall have
automatic force shut down provision in case of fire on
receiving signal from BMS System. The cooling
capacity of indoor unit will be at air inlet conditions of
27 Degree C DB and 19 Degree C WB temperature fresh
air provision compatible for Remote Operation System
Supply, installation, testing and commissioning of
following minimum capacity 4-way/2 way/radial flow
as per approval VRV Cassette Type Indoor ceiling
mounted unit equipped with synthetic washable media
pre-filter, fan section with low noise fan/dynamically
balanced blower, multispeed motor, coil section with
DX Copper coil, electronic expansion valve, outer
cabinet, drain pump, grill, necessary supports, vibration
isolation, cord less remote control etc., suitable for
operation on single phase 230 V ± 10%, 50Hz AC
supply, max noise level 60dB @ 400 cfm per
TR(minimum) complete, as required. The unit shall have
automatic force shut down provision in case of fire on
receiving signal from BMS System. The cooling
capacity of indoor unit will be at air inlet conditions of
27 Degree C DB and 19 Degree C WB temperature fresh
air provision compatible for Remote Operation System
Providing and erecting Inverter based approved make
split air-conditioning unit consisting of condensing
unit with variable speed fan motor, inverter type
hermetically sealed rotary compressor with accessories
etc. duly connected separately erected evaporating unit
and blower motor with its accessories by means of extra
supplied proper insulated copper tubing,drain PVC pipes
suitable for ( cost includes Eco Friendly green gas
charging and 15A plug top & Remote Control & MS
Stand) with necessary core cutting.
(1)For 3 Star Rating of current year
(B) for 1.5 ton capacity
Providing and erecting Inverter based approved make
split air-conditioning unit consisting of condensing
unit with variable speed fan motor, inverter type
hermetically sealed rotary compressor with accessories
etc. duly connected separately erected evaporating unit
and blower motor with its accessories by means of extra
supplied proper insulated copper tubing,drain PVC pipes
suitable for ( cost includes Eco Friendly green gas
Item Accoring to
but may be Item Work Unit Tender Rates
charging and 15A plug top & Remote Control & MS
Stand) with necessary core cutting.
(1) For 3 Star Rating of current year
(E) for 2.5 ton capacity
NOTE:- 1)The Copper Piping & Piping Circuit
should be with Minimum Number of joints, which
shall be attained by : (1) Using One End Expanded
(2) Bending the tubes instead of using elbow joints
wherever 90 degree bending is required.
(3) Piping should be routed at site in such a manner,
that brazed joints in the refrigeration piping are kept
(4) The makes of tube fittings shall be same as that of
(5) The thickness of fittings used shall be same as that
of the pipe. Copper Piping : Supply, Installation,
testing and commissioning including vaccumiazation
and Nitrogen testing of following nominal sizes of
soft/hard drawn copper refrigerant piping for VRV
system, complete with fittings, with suitable adjustable
ring type hanger supports, jointing/brazing including
accessories, insulated with XPLE Class-0 tubular
insulation/with Class-0 closed cell elastometric nitrile
rubber tubular sleeves sections of specified thickness as
given below for Suction and Liquid lines, all accessories
as per specifications etc with necessary refrigerant joint
(A) 6.4 mm dia (OD) (Soft drawn) with tube thickness
1.2 mm with 19 mm thick insulation
(B) 9.5 mm dia (OD) (Soft drawn) with tube thickness
1.2 mm with 19 mm thick insulation
(C.) 12.7 mm dia (OD) (Soft drawn) with tube thickness
1.2 mm with 19 mm thick insulation
(D) 15.86 mm dia (OD) (Soft drawn) with tube thickness
1.2 mm with 19 mm thick insulation
(E) 19 mm dia (OD) (Hard drawn) with tube thickness
1.2 mm with 19 mm thick insulation
(F) 22.2 mm dia (OD) (Hard drawn) with tube thickness
1.2 mm with 19 mm thick insulation
(G) 25.4 mm dia (OD) (Hard drawn) with tube thickness
1.2 mm with 19 mm thick insulation
(H) 28.58 mm dia (OD) (Hard drawn) with tube
thickness 1.2 mm with 19 mm thick insulation
(I) 31.8 mm dia (OD) (Hard drawn) with tube thickness
1.62 mm with 19 mm thick insulation
(J) 34.9 mm dia (OD) (Hard drawn) with tube thickness
1.62 mm with 19 mm thick insulation
(K) 38.1 mm dia (OD) (Hard drawn) with tube thickness
1.62 mm with 19 mm thick insulation
(L) 41.27 mm dia (OD) (Hard drawn) with tube
thickness 1.62 mm with 19 mm thick insulation
Control Cables and Wires : Supply installation testing
commissioning Shielded Shielded Control Cables for
Item Accoring to
but may be Item Work Unit Tender Rates
VRV System with necessary ISI mark Medium class
rigid PVC pipes with necessary accessories with
termination in machine and control equipments..(A) 2C
X 1.5 Sq mm Shielded Armoured
510 600.00 (B) 3C X 1.5 Sq mm Shielded Armoured Mtr. 153.52
511 450.00 (C) 4C X 1.5 Sq mm Shielded Armoured Mtr. 203.01
Central Control System Central Remote Controller for
above system comprising of all required Software. PC
will be supplied by client. System should control &
monitor all installed IDU / ODU. Following should be
512 65.00 minimum controlling & monitoring features that system Nos. 1854.36
should cover; Start / Stop, Temperature settings, Mode
control, Group formation, view alarms, Fault Diagnosis.
((A) Cord type remote control with thermostat, LED
Display and internal wiring for Cassette, FCU & CSU
513 250.82 (B) Central wired Remote Control System HP 1670.54
514 R & B ELECTRIC SOR (2025-26)
Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm
thick. nitrile rubber insulation. (A) 50 mm dia.
providing and erecting Highly flexible, fibre free
insulation laminated with an embossed silver-colour foil
for enhanced aesthetic and mechanical protection. The
closed cell insulation material with superior performance
in fire safety and maintenance is used for the protection
of HVAC ducts, especially in the clean room conditions
of pharmaceuticals industries. Key Features
• Pre-covered insulation with excellent aesthetics
• Low Thermal Conductivity, λ0°C ≤ 0.035 W/(m·K)
• Excellent Water vapour Diffusion Resistance, µ ≥
• Easy to clean and maintain
• Class 0 fire classification to BS 476 part 6 &
• Durable and high resistance to mechanical abuse
Supplying & erecting single phase approved make
industrial exhaust fan suitable for medium duty ring
521 20.00 mounted low noise operation suitable for medium duty Nos. 2054.34
having following dia size and maximum speed in RPM
[A] 305 mm dia 900 RPM Cat.II
Supply, installation, testing and commissioning of
HVAC Electrical Panel
The panels will be metal enclosed & be fabricated From
CRCA Sheet 14/16 SWG Suitable for indoor
522 9.00 Installations having front operated, Wall/Floor mounting Nos. 296182.5
& Non Draw out type. Panel will be completely dust &
vermin proof. All doors & cover will be fully gasket
with neoprene rubber. Panel will be painted with Powder
Coating inside & outside.
Mechanical Work
[1]GEAR LESS LIFT DRIVE (MRL) comprising of
High Starting torque Lift 3 phase 440 V A. C..
Item Accoring to
but may be Item Work Unit Tender Rates
Permanent Magnet Synchronous motor of proper rating
with high efficiency shall be used.[2] Micro processor
based / PLC, ACVVVF, vector control drive with
encoder feedback closed loop system shall be used for
lift car and door operation which shall be full collective
selective operation hall call demand response,
UP/DOWN hall stops, Main, Up/ Down Contactor with
overload and phase reversal relay and safety controls.[3]
Car with M S platform with bracings of adequate size
and to sustain the impact load cabin + passenger with
safety factor of fire for steel and side panels of Stainless
steel of sheet of grade 304 duty. Car ceiling will be S.S.
finishes with aesthetic appearance with LED ceiling
lights. Car flooring shall be of s/s 304 chaker plate
design sugeested of engineer in charge. of engineer in
charge. Car doors shall be of stainless steel grade
hairline finish with centre opening / telescopic automatic
doors. Car panel will also be S.S. 304 finished with
emergency stop device, mechanical door safety device,
facility of auto/ attended mode. All car panel buttons and
all floor switches must be with brail language as per lift
act.[4] All landing doors must be fire rated for 2 hour
shall be fully automatic centre opening/ telescopic
opening made of hairline finish steel grade of 304 with
key holes and infrared curtains with Unlocking facility
from outside [5] Appropriate battery operated
emergency light in the car along with alarm switch shall
be provided. Also, Emergency Light & Fan should start
immediately without any Time Delay as soon as power
fails. [6] Digital scrolling indicator system for up-down
arrow along with floor position indicator shall be
provided inside the car and at all floors. [7] Full height
infra red curtain with multiple cross / crossing light
beams shall be provided. [8] Automatic Rescue Device
(ARD) shall be provided accordingly of passenger
capacity with Manual Rescue Operation ( Manual
Cranking Facility). [9] Audio visual indication in the lift
car showing over loading shall be provided such that
doors kept open till excess load is removed.[10] Spring
buffers/PU Buffers shall be provided. [11] Car fan as per
passenger capacity with automatic sleep timer shall be
provided. [12] Voice annunciator with suitable music
shall be provided in lift car.
[13] Self diagnostics system for operational and safety
parameters shall be provided in control panel.
[14] Mechanical over speed governor with governor
calibration as per actual site parameters and submission
of calibration certificate submission, door key holes in
the floor doors, fireman switch shall be provided. [15]
Lift machine hoisting arrangement in the lift machine
room and monkey ladder for lift pit should be provided
by the lift agency, along with the other steel structure
works, foundations for the machine etc… [16] In the
hoist way fascia plate shall be provided without any
extra cost, where ever required as / if directed by
Item Accoring to
but may be Item Work Unit Tender Rates
engineer in charge. [17] Permanent wiring with
necessary safety devices like RCCB in all circuit, Over
Voltage Under Voltage protection and THD eliminator
in circuit for lift machine room and lift well with proper
numbers of light points, with fixtures, exhaust fan and
plug points shall be provided by the agency. Only
phase Power Supply shall be made available by
department in lift machine room. Necessary Earthing as
per Lift Act/Rules shall be arranged by Lift Agency.
[18] Any civil/ electrical works for additional and
alteration in lift shaft and machine room related to
erection of lift shall be made by lift agency without any
extra cost. (granite/marble fixing around all landing door
openings are not in lift agency’s scope.) [19] Agency
has to provide all working drawings and documents and
liaison services for obtaining all necessary permission
from lift inspector and other authorities. [20] acrylic
transparent licence/display A4 size holder in lift car
[20A] As per statutory requirement of Govt. Of Gujarat
lift & escalator act 2000, lift agency has to provide
1. Car top safety barricade
2. Push & talk communication system.
3. Fireman's switch operation at Ground Floor.
4. carrying out third party lift inspection during/after lift
erection and provide report by third party authorized by
concern licensing authority 5.agency has to provide
third party insurance upto completion of free
maintenance period and submit the document for the
same. [21] Car Panel Operating Buttons with floor
position indicator/buttons must be of Auto Glow type
clearly visible when view from inside cabin.[22] For
Physically Handicapped person Full Length Handrails of
hairline finish steel grade of 304 should be provided at
appropriate height on the Rear & Side Wall Panels in
Lift Car. [23] With Necessary KVA rating voltage
controlled Stabilizer suitable for your controller, drive
and all equipments of lift. [24] Necessary rating of DP
Elcb and FP Elcb required for lift is in scope of work
which rating is sugested by CEICED Department
(electrical Inspector) (B) SPECIAL FEATURES
DESCRIPTION OF LIFTS for PREMIUM category
Advanced control system dual 64 bit embedded
microprocessor with CANBUS Serial Communication
mode including Regenerative power efficient
operation,on site programming facility, Anti nuisance,
Pte-opening, BMS/RMS with necessary online real time
monitoring system having necessary connectivity for
remote monitoring & other suitable supporting
hardware & software devices to fulfil the purpose.
Floor Indication LCD Display with call registration &
brail mark with arrival gong and hall lantern & TFT
Screen in the car with MP3 Voice Announcer. 3. CAR
Panel should be Scratch resistive SS Moonrock finish /
Hair Line / Honeycomb for car and all Doors, All
landing doors must have fire rating up to 2 hours and car
Item Accoring to
but may be Item Work Unit Tender Rates
door must have multi-level crisscross beam door
protection. 4. To & fro communication system & wiring
(i.e. car , control room & guard room ) and Each
elevator are equipped with remote monitoring
system.agency has to provide mobile app and user id
and password for monitoring 8 / 10 Passengers,. Ground
plus 7 upper floor with Rated Speed of 1.75/
m/sec., (C) With General PLUS ADDITIONAL
SPECIAL FEATURES attached herewith. Prem. Cat.
Total Amount Say
Total Amount Say
I/ We am/ are willing to carry out the work @ _____________ % above /Below __________Percentage (should be written in figures and
words) of the Estimate rates mentioned above amount of my/ our Tender work out as under
* Estimated Amount * Estimated Amount
Put On Tender Rs. 31,12,93,309.00 Put On Tender Rs.
Deduct…………% Below Rs. ………………………. Add …………% Above Rs. ……………………….
(* Please strike out whichever is not applicable.)
Note 1: All works shall be carried out as per public works department handbook and other sepecifications of division or as directed.
Note 2: All the columns is Schedule should be filled in ink and the total of the entries in the last column should be struck by the contractor
under his signature.
Note 3: Rates quoted include clearance of site (prior commencement of work and at its close) in all respects and hold good for work under
all conditions, site, moisture, weather etc.
Note 4: To be continued on additional sheets, if found necessary.
Name of Work : THE CONSTRUCTION OF BIRTH & DEATH AND OTHER DEPT OFFICES AT SARDAR MARKET
VADODARA MUNICIPAL CORPORATION
Item According to
but may be Item Work Unit Tender Rates
Signature of Contractor with Seal Signature of Contracting Authority with Seal
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
000 JAHERAT 15-02-2026.pdf
001 VMC BLDG Vol 1_18.02.2026.pdf
002 SBD_VMC BLDG Vol 2_18.02.2026.pdf
003 BUILDING SPECIFICATION PART-I.pdf
004 BUILDING SPECIFICATION PART-II.pdf
005 BUILDING SPECIFICATION PART-III.pdf
006 BUILDING SPECIFICATION PART-IV.pdf
007 ELE Technical Specification and Makes.pdf
008 ARCHITECTURAL CIVIL LAYOUT.pdf
009 VMC NEW BUILDING OFFICE_ABSTRACT.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .