| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹79,888Qualified Make: LUMINOUS
Model: LUMINOUS 5KVA 46 BAHADUR MARG DEWAS DEWAS MADHYA PRADESH 455001 DEWAS MADHYA PRADESH 455001 | DEWAS | MADHYA PRADESH | 455001 | Make: LUMINOUS
Model: LUMINOUS 5KVA | L1 | Qualified | |
| 2 | L2₹79,900+₹12 (0.02%)Qualified Make: LUMINOUS
Model: LUMINOUS 5KVA 1ST FLOOR F 05 PARKER SUITES NH 01 SECTOR 62 KUNDLI SONEPAT HARYANA 131028 SONEPAT SONIPAT HARYANA 131001 | SONIPAT | HARYANA | 131028 | Make: LUMINOUS
Model: LUMINOUS 5KVA | L2 | Qualified | |
| 3 | L3₹82,340+₹2,452 (3.07%)Qualified Make: BPE
Model: BPE 5 kva 4050 vah 2 years 30 mins backup AAREY MILK COLONY MUMBAI MAHARASHTRA 400065 | MUMBAI SUBURBAN | MAHARASHTRA | 400065 | Make: BPE
Model: BPE 5 kva 4050 vah 2 years 30 mins backup | L3 | Qualified | |
| 4 | L4₹85,214+₹5,326 (6.67%)Qualified Make: MICRO POWER
Model: MPT ZEST SERIES -5/30 KALI MANDIR ROAD GHAZIABAD UTTAR PRADESH 201010 | GHAZIABAD | UTTAR PRADESH | 201010 | Make: MICRO POWER
Model: MPT ZEST SERIES -5/30 | L4 | Qualified | |
| 5 | L5₹86,900+₹7,012 (8.78%)Qualified Make: BPE
Model: BPE NIY 5 KVA 5040 VAH Online UPS PB1110L16 30 Min 1Yrs DELHI DELHI 110024 | SOUTH EAST DELHI | DELHI | 110024 | Make: BPE
Model: BPE NIY 5 KVA 5040 VAH Online UPS PB1110L16 30 Min 1Yrs | L5 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
30 Jul 2018, 11:00 amClosed
Online UPS Experience with Gov. Required 2 Year (s) Online UPS ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA 5.0 KVA Technology IGBT-PWM without inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer
IGBT-PWM with inbuilt isolation transformer
IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave
50Hz single phase 160V - 260V sinewave
50Hz
Three phase 300 V - 450V sinewave
50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz
3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 30 30 Minimum VAH (VAH) 4050 Warranty for UPS (Years) 1 1
2
3
4
5 1/4 Movable trolly for Batteries Without With
Without
Without trollery but with rack Warranty for battery 1 1
2 Degree of Protection IP20 IP21
IP20 Cabling 5 meters for input and out put With With
Without Paralleling kit for synchronising Without With
Without Installation and Commissioning Yes - CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.0 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I
II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) </= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage
Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage
Output AC Volt age
Current
Frequency
Battery Voltage and Current Yes - Indicators for mains presence
Battery charging and discharging
Output Over Load
Low Battery Voltage Yes - 2/4 REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C
two cycles of (12+12) hours each 2007) Yes - Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes - Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. 38935D - Type Test Certificate date 27-02-2014 - Name of Lab NTH - Address of Lab GHAZIABAD - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Arun Aeri 382721
Air Force Station Vadsar
1 15
357130
GEM/2018/B/50593
Online UPS
15 days
Gujarat; Gandhinagar
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Online UPS Experience with Gov. Required 2 Year (s) Online UPS ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA 5.0 KVA Technology IGBT-PWM without inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer | - | - | - |
| IGBT-PWM with inbuilt isolation transformer | - | - | - |
| IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave | - | - | - |
| 50Hz single phase 160V - 260V sinewave | - | - | - |
| 50Hz | - | - | - |
| Three phase 300 V - 450V sinewave | - | - | - |
| 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz | - | - | - |
| 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 30 30 Minimum VAH (VAH) 4050 Warranty for UPS (Years) 1 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 5 1/4 Movable trolly for Batteries Without With | - | - | - |
| Without | - | - | - |
| Without trollery but with rack Warranty for battery 1 1 | - | - | - |
| 2 Degree of Protection IP20 IP21 | - | - | - |
| IP20 Cabling 5 meters for input and out put With With | - | - | - |
| Without Paralleling kit for synchronising Without With | - | - | - |
| Without Installation and Commissioning Yes - CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.0 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I | - | - | - |
| II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) </= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage | - | - | - |
| Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage | - | - | - |
| Output AC Volt age | - | - | - |
| Current | - | - | - |
| Frequency | - | - | - |
| Battery Voltage and Current Yes - Indicators for mains presence | - | - | - |
| Battery charging and discharging | - | - | - |
| Output Over Load | - | - | - |
| Low Battery Voltage Yes - 2/4 REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C | - | - | - |
| two cycles of (12+12) hours each 2007) Yes - Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes - Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. 38935D - Type Test Certificate date 27-02-2014 - Name of Lab NTH - Address of Lab GHAZIABAD - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Arun Aeri 382721 | - | - | - |
| Air Force Station Vadsar | - | - | - |
| 1 15 | - | - | - |
Exempted
30 Jul 2018
20 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_357130.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .