Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.7 LAccepted-AOC 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | L1 | Accepted-AOC L1 and Lowest | |
| 2 | L2₹40.5 L+₹4.8 L (13.5%)Rejected-AOC | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹51.1 L+₹15.4 L (43.2%)Rejected-AOC | L3 | Rejected-AOC Not Lowest |
| Sl No | Description | Qty | Unit | om sai enterprises L1 | Mr Madhusudhan Kotarki L2 | Srinivasa Consructions L3 |
|---|---|---|---|---|---|---|
| 0.00Schedules of Works | ||||||
| 1.00Material and labour for concealed/ casing Point wiring for one light point/fan point /controlled by one switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through existing PVC conduit but including 2mm thick galvanised steel pressed sunken box suitable modular switch socket (Min 60mm deep, suitable length) concealed/casing in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket / regulator etc, including provision of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. complete all as specified and as directed. (switches/ socket / regulator shall be measured and paid separately under appropriate item of BOQ). | ||||||
| 1.01 | (a) One light point controlled by one way 5 Amp switch complete all as specified and as directed | 18 | POINT | 700 ₹12,600 | 650 ₹11,700 Lowest | 1,000 ₹18,000 |
| 1.02 | (b) One 3 pin socket out let 05 Amps on same board complete all as specified and as directed | 16 | POINT | 200 ₹3,200 Lowest | 500 ₹8,000 | 300 ₹4,800 |
| 1.03 | (c) One 5 pin socket out let 05 Amps on independent board complete all as specified and as directed | 21 | POINT | 700 ₹14,700 Lowest | 700 ₹14,700 Lowest | 1,000 ₹21,000 |
| 2.00 | Material and labour for concealed/casing Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through existing PVC conduit but including 2mm thick galvanised steel pressed sunken box suitable modular switch socket (Min 60mm deep, suitable length) concealed/casing in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket / regulator etc, including provision of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. complete all as specified and as directed.
(switches/ socket / regulator shall be measured and paid separately under appropriate item of BOQ). | 30 | POINT | 1,000 ₹30,000 | 700 ₹21,000 Lowest | 2,500 ₹75,000 |
| 3.00 | S & F modular switch 1 way 6 amps, 1 module complete all as specified | 25 | EACH | 80 ₹2,000 | 65 ₹1,625 | 30 ₹750 Lowest |
| 4.00 | S & F modular switch 1 way 16 amps, 1 module complete all as specified | 14 | EACH | 130 ₹1,820 | 85 ₹1,190 Lowest | 90 ₹1,260 |
| 5.00 | S & F modular sockets 6 amps, 2/3 pin combined two module complete all as specified | 22 | EACH | 120 ₹2,640 | 100 ₹2,200 Lowest | 100 ₹2,200 Lowest |
| 6.00 | S & F modular sockets 6/16 amps, 2/3 pin combined two module complete all as specified | 14 | EACH | 180 ₹2,520 | 200 ₹2,800 | 156 ₹2,184 Lowest |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
6 Aug 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Bidar
Garrison Engineer (Air Force) Bidar, Military Engineer Services, Air Force Station Bidar, Bidar-585401
PROVISION OF UPS WITH BATTERIES IN HAWK TECH AREA, PROVISION OF GEYSER AND ASSOCIATED WORKS SERVICES IN CERTAIN MD ACCN AT HAWK ENCLAVE AND PROVISION OF CERTAIN E/M WORK SERVICES FOR OTM ACCN AT AFS BIDAR
2025_MES_718163_1
GE(AF)/BID/TOKEN/16 OF 2025-2026 8167
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Bidar
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) Bidar
₹86,000
Yes
11 Oct 2025
2 Jul 2025
13 Aug 2025
2 Jul 2025
6 Aug 2025
16 Jul 2025
2 Jul 2025 - 9 Jul 2025
Amount
Schedules of Works
Material and labour for concealed/ casing Point wiring for one light point/fan point /controlled by one switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through existing PVC conduit but including 2mm thick galvanised steel pressed sunken box suitable modular switch socket (Min 60mm deep, suitable length) concealed/casing in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket / regulator etc, including provision of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. complete all as specified and as directed. (switches/ socket / regulator shall be measured and paid separately under appropriate item of BOQ).
(a) One light point controlled by one way 5 Amp switch complete all as specified and as directed
(b) One 3 pin socket out let 05 Amps on same board complete all as specified and as directed
(c) One 5 pin socket out let 05 Amps on independent board complete all as specified and as directed
Material and labour for concealed/casing Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through existing PVC conduit but including 2mm thick galvanised steel pressed sunken box suitable modular switch socket (Min 60mm deep, suitable length) concealed/casing in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket / regulator etc, including provision of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. complete all as specified and as directed. (switches/ socket / regulator shall be measured and paid separately under appropriate item of BOQ).
S & F modular switch 1 way 6 amps, 1 module complete all as specified
S & F modular switch 1 way 16 amps, 1 module complete all as specified
S & F modular sockets 6 amps, 2/3 pin combined two module complete all as specified
S & F modular sockets 6/16 amps, 2/3 pin combined two module complete all as specified
Supply and fixing modular white cover suitable with frame 8 module complete all as specified and directed.
Supply and fix modular metal flush box with 8 module complete all as specified and directed.
M & L in replacement of Submain wiring with 2 runs of single core 2.5 sqmm PVC insulated unsheathed (FRLSH) multistranded 1100 volts grade with copper conductor drawn through and including non-metallic Rigid PVC Conduit ISI marked and its accessories including one run of single core 2.5 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuity conductor along with the wiring and connected from DB to DB/main board complete all as specified and directed. Note :- 2 runs 2.5 sqmm single core copper conductor, one run of 2.5 sqmm copper conductor earth wire and PVC conduit and its accessories will be measured as one unit.
M & L in replacement of Submain wiring with 2 runs of single core 4 sqmm PVC insulated unsheathed (FRLSH) multistranded 1100 volts grade with copper conductor drawn through and including non-metallic Rigid PVC Conduit ISI marked and its accessories including one run of single core 4.0 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuity conductor along with the wiring and connected from DB to Sub DB complete all as specified and directed. Note :- 2 runs 4 sqmm single core copper conductor, one run of 4 sqmm copper conductor earth wire and PVC conduit and its accessories will be measured as one unit.
M & L in replacement of Submain wiring with 4 runs of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metallic rigid PVC conduit ISI marked and its accessories including Single run of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuity conductor along with the wiring and connected from DB to Three Phase socket complete all as specified and directed. Note :- 4 runs of 6 sqmm single core copper conductor, one run of 6 sqmm copper conductor earth wire and PVC conduit and its accessories will be measured as one unit.
M & L in replacement of Submain wiring with 4 runs of single core 10 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metallic rigid PVC concealed conduit ISI marked and its accessories including Single run of single core 10 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuity conductor along with the wiring and connected from VTPN DB to DB/main board complete all as specified and directed. Note :- 4 runs of 10 sqmm single core copper conductor, one run of 10 sqmm copper conductor earth wire and PVC conduit and its accessories will be measured as one unit.
M & L in replacement of Submain wiring with 4 runs of single core 16 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metallic rigid PVC concealed conduit ISI marked and its accessories including Single run of single core 16 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuity conductor along with the wiring and connected from UPS to VTPN DB complete all as specified and directed. Note :- 4 runs 16 sqmm single core copper conductor, one run of 16 sqmm copper conductor earth wire and PVC conduit and its accessories will be measured as one unit.
M & L in replacement of Submain wiring with 4 runs of single core 25 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metallic rigid PVC concealed conduit ISI marked and its accessories including Single run of single core 25 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuity conductor along with the wiring and connected from panel to UPS complete all as specified and directed. Note :- 4 runs 25 sqmm single core copper conductor, one run of 25 sqmm copper conductor earth wire and PVC conduit and its accessories will be measured as one unit.
S & F in replacement of sheet metal enclosure MCB VTPN 8 way Double door Ready to use DBs - Provided with insulated vertical phase bus-bars |neutral bar/s with shroud/s | earth bar/s | sticking saddles | cement spill protector | color-coded interconnecting wire set | cable ties | blanking plates and circuit identification labels With provision for 4 Pole MCCB 160 A as incomer and SP/SPN MCBs as outgoing complete all as specified and directed. Make L&T and equivalent in Legrand and Indo Asian.
S & F MCB DB TPN 4 way with 200 Amps rated copper busbar with mild sheet enclosure vertical double door type, IP protection, suitable for fixing MCBs including connecting etc complete all as specified and directed
S&F MCB DB, SPN, 8 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, single door type, IP protection, suitable for fixing MCBs including connecting etc., complete all as specified and as directed.
S&F in replacement of 63 A ,5 Pin (3 P+N+E) Metal Plug & Socket Enclosure for Three Phase connection all as specified and directed. Model:- DBMPS463SD, Make :-L&T or equivalent in Schneider and Legrand.
Supply and fix MCB, TPN 415 volts, 63 Amps, 'C' curve type, with 10KA breaking capacity. Make-Standard/Havells/Indo Asian.
Supply and fix MCB TPN 415 volts 16 -32A Amps 'C' curve type, with 10KA breaking capacity. Make-Standard/Havells/Indo Asian.
Supply and fix MCB SPN 32 Amp 240 V 50 Hz AC Supply 'C' curve type, with complete all as per specified and directed.
Supply and fix in replacement MCB SP 6 to 32 amp 'C' curve type, with complete all as per specified and directed.
Supply & Fix online double conversion type, IGBT based PFC and inverter section UPS system Capacity of 30 KVA having standard for 30 min back up three phase AC input 380-415V 3 phase and output voltage 400V with reared power capacity 30 KVA , ambient temperature up to 40 degree centigrade with heat dissipation 1410 W along with high efficiency inbuilt t display including complete all robust electrical design specified and as directed. Make : schneider , ABB, Microtek, siemens
Supply & Fix Battery with the capacity of 100 AH, 12 V DC supply with suitable back up duration up to suitable time and providing proper connection to UPS complete all as specified and directed. Note: Cost of MCCB and fixing arrangement will be included in the quoted rate. Make: Exide, Amaron, luminous
S & F Battery rack made up of angle iron frame duly painted suitable for accommodating 24 * 100AH , 12 Volts DC battery and its wiring and electrical accessories complete all as specified as per site requirement as directed by Engr-in-charge
S & F in replacement of Test point terminal block made of gun metal or Phosphorus bronze size 75 x 75 x 25 mm, drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw complete all as specified and as directed.
S&F GI Pipe of 40 mm Dia, ISI Marked , light grade to cover the copper strip (25 mm x 3.15mm) Complete all as Specified.
S&F Porcelain insulator of suitable size for proper securing to roof conductor of aluminium strip including dismantling of unserviceable insulator complete all as specified and directed.
M/L for providing earthing with GI earth plate electrode 600 x 600 x 6 mm thick buried directly in ground vertically to depth of not less than 2.25 mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to GI earth wire of 4mm by means of bolts, nuts, washers of GI and provision of earth lead, GI protection pipe with 15mm light grade galvanized including necessary earth work in any type of soil, PCC 1:3:6 type CI (using 20mm graded stone aggregate) earth chamber and 1:2:4 type B1 RCC cover fitted with50mm thick with 6mm dia MS bars complete all as shown in SSR Pt - 1 electrical plate No 3. Note : Quoted rate deemed to include the cost or excavation and earth work PCC Chamber, funnel cover etc.
M/L for providing earthing complete with Copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level, Alternate layers of charcoal) & common salt Crystal, in and including back filling compound in layers and filling up with black cotton soil up to the top edge/ ground level and connected to copper earth strip 20 x 3.15 mm by means of bolts, nuts, check nuts & washers of copper and connecting to earth dolly, equipment all as shown in electrical plate No. 5 of SSR Part I of 2009 & testing complete including 40mm dia light grade GI pipe up to 7.5 mtr long, excavation in any type of strata, PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm with frame, including 20 mm bore water pipe medium grade GI Tubing including GI Funnel , wire mesh etc. ( NOTE :- Copper earth continuity conductor 20x3 and GI light grade protection pipe 40mm dia beyond 7.5 mtr shall be measured and paid under the respective items ).
M&L for Copper strip of size 20x3.15 mm complete including cut to length and size to match the existing system and fixing the same to the wall / roof on suitable porcelain insulators along with fixing materials complete all as specified and directed. Note :1. Porcelain insulators will be measured and paid separately under the respective of the schedule 2. Materials required for removing the u/s earth strips from any height the technical buildings (Approx. Up to 10 mtrs height) deemed to be included in the quoted rate
S & F 100A BUS BAR Chamber Copper type including step up design for safe power distribution complete all specie and directed
S & F cable tray size not less than 5 x 10cm (size H x W) cable ducts/wiring channels/cables open slot wiring raceway duct, cable management channel cord track to hide cable wires for run electric cable to further distribute with desks, shelves and DB's, panels
Supply and fixing Geyser 25 Litres capacity having features shock safe plug, feroglas technology, PUF insulation, incoloy glass coated heating element, anode rod, 0.8 MPa high working pressure, whir flow technology IPX-4 protection, adjustable knob for temperature setting, plasto shield outer coating, pipe connections, also PVC connectors 45 cm long both end brass nut suitable for hot/cold water supply and screw down 15mm GI pipe, grouting 4 Nos OF M12 x 100mm mild steel bolt in stone / brick masonry wall and making good the surface to match with the existing surface in cement mortar 1:4 suitable for hanging geysers complete all as specified and as directed MAKE : Havells/Crompton/Bajaj
Supply and Fixing in repairs 15mm bore dia of pipe, chromium plated cast copper alloy Bib taps fancy type with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule with wall flange, complete all as specified and as directed. Make: Prayag CAT No.PIS-08 or Techno commercial equivalent of approved makes specified here-in-after.
Supply and Fixing in repairs stop valves, 15mm bore dia of pipe, fancy type, chromium plated cast copper alloy high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. Make: Prayag CAT No. 8510 or Techno commercial equivalent of approved makes specified here-in-after.
Supply and Fixing GI tubes 15mm dia medium grade galvanised with all fittings and fixed complete to walls and connecting to the existing line complete with the bends & elbows and necessary accessories, complete all as specified and directed
S & F for point wiring for 15 Amps S/S combination / earth plug socket complete with two runs of 2.5 sqmm, PVC insulated, unsheathed FRLS cable 1100 volts grade, multi stranded copper conductor PVC conduit on surface/ in wall/ roof etc. and including provision of one run of PVC insulated 2.5 sqmm copper conductor for earth continuity and connected to common earth dolly and pressed steel terminal boxes made out of 1.6mm thick MS sheet concealed in wall and laminated sheet cover of 3mm thick on top for housing the switch socket complete all as specified and directed.
Supply and fix, MCB SPN 20 Amps, 240 V 50 HZ, C-curve, 10 ka breaking capacity, including making electrical connection with the help of lugs/thimbles, complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of industrial type metal clad plug top & socket single pole and a neutral link earth enclosure with MCB SP 20 Amps complete all as specified and as directed
Taking down carefully copper/ aluminium point wiring (Light, fan, socket or power) complete fittings such as switches, ceiling roses, pendants, regulators, sockets, etc for credit
S & F in replacement ceiling rose surfaces Bakelite 63.5 X 28 mm three terminals all as directed by Engr-in-Charge
Supply, laying, testing XLPE insulated screened, PVC inner sheathed galvanised steel strip or wire, armoured, heavy duty LT UG electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm 2 core complete all as specified.
Excavating in trenches in soft/loose soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out as soft/ loose soil complete all as specified and directed
Returning filling in including spreading levelling, watering and well ramming in layers n-exceeding 25 cm complete all as specified and directed
Removing excavated material n exceeding 50 m and depositing where directed at level n exceeding 1.5 m above the staring point as soil complete all as specified and directed.
Sand Cushioning (dry sand) to under ground under ground cable for cable protection in layers of 23 cm thick (8 cm thick before laying of cable and 15 cm thick after laying of cable) in trenches complete all specified and as directed. Note:- Only punned thickness shall be measured.
Supplying and laying unreinforced pre cast concrete cable cover class LV type 1 flat size 250x150x40 mm laid in trenches as protection to cables all as directed
S & F 40 mm dia Galvanised steel tubing light grade including all necessary fittings laid in trenches, fixed to walls, poles, under road/ floor etc for cable protection, complete all as specified and directed.
M/L for providing earthing with GI earth plate electrode 600 x 600 x 6 mm thick buried directly in ground vertically to depth of not less than 2.25 mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to GI earth wire of 4mm by means of bolts, nuts, washers of GI and provision of earth lead, GI protection pipe with 15mm light grade galvanized including necessary earth work in any type of soil, PCC 1:3:6 type C1 (using 20mm graded stone aggregate) earth chamber and 1:2:4 type B1 RCC cover fitted with 50mm thick with 6mm dia MS bars complete all as shown in SSR Pt - 1 electrical plate No 3. Note : Quoted rate deemed to include the cost or excavation and earth work PCC Chamber, funnel cover etc.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)
Supply and fixing LED tube light fitting commercial of 20 W 4 feet long environment friendly polycarbonate housing & integrated electronic driver complete all as specified and directed by Engr-in-Charge
Supply and fixing high efficient LED flood light fitting of 45/50 W, 230 V, AC outdoor type with high pressure die cast aluminium housing and heat resistant, toughened glass IP 65, 10 KV SPD, 100 Lumen/Watt and wired with accessories complete all as specified
Supply and fixing high efficient LED flood light fitting of 70 W, 230 V, AC outdoor type with high pressure die cast aluminium housing and heat resistant, toughened glass IP 65, 10 KV SPD, 100 Lumen/Watt and wired with accessories complete all as specified
Supply and fixing high efficient LED flood light fitting of 100 W, 230 V, AC outdoor type with high pressure die cast aluminium housing and heat resistant, toughened glass IP 65, 10 KV SPD, 100 Lumen/Watt and wired with accessories complete all as specified
Mr Madhusudhan Kotarki (BID ID -3373435)
Srinivasa Consructions (BID ID -3376611)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .