Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.5 LAccepted-AOC VILL PO KAMPA NEAR ASHRAM DIST NORTH 24 PGN KOLKATA WB | 24 PARAGANAS NORTH | WEST BENGAL | 743193 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹48.7 L+₹7.1 L (17.0%)Rejected-Finance | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹49.2 L+₹7.6 L (18.1%)Rejected-Finance | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹50.1 L+₹8.5 L (20.4%)Rejected-Finance 32 GOLA MAHAL P O BARRACKPORE DIST NORTH 24 PARGANAS PIN 700 120 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L4 | Rejected-Finance Not the lowest bidder |
Tender Value
₹38.0 L
EMD Value
₹75,960
Closing Date
15 Aug 2023, 6:00 pmClosed
GE Barrackpore
Office of the Garrison Engineer Barrackpore
PROVN OF 4 X SECURITY LIGHT WITH POLE IN UNIT AREA AND PROVN OF LIGHTING CONDUCTOR IN BLDG NO NP-56 CONNECTING FOOTPATH FROM BLDG NO NP-163 TO T-250 PROVN OF TOILET CUM BATHROOM NEAR BLDG NO NP-151 AND PROVN OF IRON
2023_MES_609639_1
8793/E8
Open Tender
Civil Works
Item Rate
180 days
Barrackpore
Refer to tender documents
3 documents required · 3 mandatory
₹500
GE Barrackpore
₹75,960
Yes
14 Sept 2023
18 Jul 2023
17 Aug 2023
18 Jul 2023
15 Aug 2023
1 Aug 2023
Amount
PART-I Dismantling fencing wire mesh, any type complete all as specified and directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground embedded in concrete, brick work, masonry etc complete all as specified and directed.
Excavating in post holes (or similar holes) in soft /loose soil each not exceeding 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding 50m and making good the surface complete all as specified and directed.
Surface excavation in soft /loose soil not exceeding 30cm deep and averaging 15 cm deep and getting out complete all as specified and directed.
Surface dressing in soft /loose soil not exceeding 15 cm deep and getting out complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation or for shafts, well, cesspits, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and exceeding 1.5 mtr but not exceeding 3.00m in depth for foundation or for shafts, well, cesspits, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in hard/dence soil complete all as specified and directed.
Excavating over areas, exceeding 1.5 m but not exceeding 3.00 m deep and getting out in soft/loose soil complete all as specified and directed.
Excavating over areas, exceeding 1.5 m but not exceeding 3.00 m deep and getting out in soft/loose soil complete all as specified and directed.
Removing surplus excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm, soil complete all as specified and directed.
M&L for broken stone or boulders hardcore of gauge not exceeding 63mm, deposited spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for broken bricks hardcore of gauge exceeding 63mm but not exceeding 100mm deposited spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC (1:2:4) type B-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in roof kerbs or mud stops, top of chajjas, coping, bed plates, basement for water tank etc rounded or chamfered on edges including necessary form work finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for precast cement concrete (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) in louvers and jallies 45mm thick including all moulings but excluding frame set in cement mortar (1:4) complete with joints to match complete all as specified and directed.
M&L for RCC M-25 Design Mix (using 20mm graded crushed stone aggregate) as in foundations including rafts, footings, foundation beam, plinth beams, bases for columns etc , basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed.
M&L for RCC M-25 Design Mix (using 20mm graded crushed stone aggregate) as in column, pillar, piers, post and struts etc complete all as specified and directed.
M&L for RCC M-25 Design Mix (using 20mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and directed.
M&L for RCC M-25 Design Mix (using 20mm graded crushed stone aggregate) used as in slab supported on walls, beams and columns in floors, roofs, landing, balconies, canopies, deck slabs and in shelves and like etc complete all as specified and directed.
M&L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3, including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage, excavation, opening wherever required complete all as specified and directed.
M&L for reinforcement cement concrete (1:1.5:3) type A-1 (using 20mm graded crushed stone aggregate) as in chajja & challah hoods complete all as specified and directed.
M&L soling (or sub base) with broken boulders or quarried stone, inter stices filled, surface formed and rolled and consolidated to required gradient and camber complete all as specified and directed.
M&L for cutting chases, in brick wall, pinning in and making good to facing where required and pointing in cement mortar (1:3), to ends or edges of landing, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing etc and making good the disturbed surface, cutting not exceeding 10cm girth complete all as specified and directed.
M&L for brick work with sub class 'B' bricks locally available best quality straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for brickwork with subclass 'B' bricks locally available best quality , straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed.
Supply only integral water proofing compound liquid, ISI marked complete all as specified and directed.
Providing form work to sides of concrete foundation, footing, base of column, raft & plinth beam for flat, rough finish surface of concrete complete all as specified and directed.
Providing form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc for flat, rough finish surface of concrete complete all as specified and directed.
Providing form work to sides of pillar, posts, struts, piers, columns and stanchions for flat, rough finish surface of concrete complete all as specified and directed.
Providing formwork to the soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200 mm thick (horizontal or sloping ) and making flat, rough finished surfaces of concrete complete all as specified and directed
Providing formwork to chullah hoods, chajjas, troughs and similar items including edges for flat, rough finish surface of concrete complete all as specified and directed.
S&F of factory made solid PVC door frame of size 50mm X 47mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube as per specification and drawing as mentioned in SSR Part-II (2020), Section 8, Page No. 178 complete all as specified and directed.
S&F of factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, as per specification & drawing as mentioned in SSR Part-II (2020), Section 8, Page No.174 complete all as specified and directed.
S&F of 250 mm aluminum alloy, anodised , sliding door bolt with hasp and staple (bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy and fixed complete all as specified and directed.
S&F of 200 mm long aluminium, anodised, barrel tower bolts of extruded section( IS-204 (Part-2) : 1992) and fixed complete all as specified and directed.
S&F of 150 mm long aluminium anodised extruded alloy handle fabricated type(IS-208: 1996) complete all as specified and directed.
S&F of 100 mm long cold rolled mild steel butt hinges, medium weight complete all as specified and directed.
M&L for TMT bars 10 mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F of TMT bars 6mm to 8mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Supply only MS round bars 10mm dia for securing chain link fencing fixed to RCC fencing posts as per Fe-410-W (Gde- E-250) quality 'A' or Fe-290 (Gde E-165) complete all as spcrified and directed. (Note: Meterials to be used in item No. 50.00 here-in-before)
S&F of mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or forged into spikes; framed guard bars; barred iron doors; ladders, railings, framed brackets, walk ways, frame work of water tank and similar work conforming to Fe-290-0 Gde-E-165 complete all as specified and directed.
S&F for mild steel works for posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F of mild steel work, flat iron as in fencing post support conforming fo Fe-290-Gde-E-165 complete all as spcrified and directed.
Supply only MS galvanised iron chain link fencing any size and type complete all as specified and directed.
S&F for galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings & straining & fixing to any type of standard rails straining bolts, including, securing or tying at crossings with & provision of galvanised mild steel wire, staples or steel pins, etc. after and including taking down old unserviceable galvanised steel barbed wire complete all as specified and directed. (Note: Each line of wire to be measured).
Fixing only galvanised iron chain link fencing including line wires, any mesh, size and type to any type of standards, rails, staining bolts, etc. and fixed with 10 mm dia MS round bars and straining including provision of binding wire for securing chain link fencing as per relevant IS specification and as approved complete all as specified and directed. (Note: 10 mm dia MS round bar shall be measured and paid separately under Item No.44.00 here-in before as "supply only")
S&F for rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates including where required drilling, fittings, riveting or welding connecting with fish plate, gusset plates etc of Fe-410-W (Gde E-250) quality 'A' complete all as specified and directed.
M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing of Fe-410W (Gde E-250) quality 'B' complete all as specified and directed.
S&F for mild steel screw bolts (machine made) 11 to 15mm with hexagonal head at one end and screwed the other end, each screw end to be fitted with two washers and one hexagonal or square nut, length of bolts 50mm to 100mm complete all as specified and directed.
S&F of steel ventilators with top hung shutters including box type hinges, steel handle & steel peg stay complete all as specified and directed.
S&F of steel Windows with side hung shutters including box type hinges, steel handle & steel peg stay complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C-2 (using 20mm graded crushed stone aggregate), as in sub base to footpath and floor/plinth protection complete all as specified and directed.
M&L for 100mm thick PCC (1:3:6) type C-2 (using 20mm graded crushed stone aggregate), as in sub base to footpath and floor/plinth protection complete all as specified and directed.
M&L for 100mm thick PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate), as in sub base to footpath and floor complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C1 (using 20mm graded crushed stone aggregate) as in plinth protection & floor including finishing the cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L for 25 mm thick cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in floor/paving etc finished even and smooth without using extra cement complete all as specified and directed.
M&L for non skid (joint free) ceramic coloured tiles of 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match with shed of tiles over and including 15mm thick screed bed or beading layer of cement mortar (1:4) for laying floor finishes complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface of size 450 mmX 300 mmX 7 mm thick or equivalent set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering of cement mortar (1:3) complete all as specified and directed.
M&L for 20mm thick granite (any type) work (table rubbed and polished) machine cut in steps, jambs, pillars, window cill, cooking platform etc bedded and jointed with grey cement slurry and pointed with white cement (1:2) using marble dust with admixture of pigment to match the granite stone including and polishing over and including 15mm thick cement mortar (1:4) as screed bed complete all as specified and directed.
M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations not exceeding 15mm wide complete all as specified and directed.
M&L for 60mm thick machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment confirming to IS 15658-2008 (M-35 grade) laying over and including 50mm thick sand filling complete all as specified and directed.
M&L for 80mm thick machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment confirming to IS 15658-2008 (M-40 grade) laying over and including 50mm thick sand filling complete all as specified and directed.
M&L neeru finish to plastering surface all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar (1:6) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5mm thick in cement mortar (1:3) on brick work or concrete surfaces of ceiling, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:4) on other than brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick cement plaster on concrete surface on top of RCC roof with cement mortar (1:4) mixed with WPC @200ml per 50 Kg of cement or as per manufacturer's instructions , finished the surfaces even and smooth without using extra cement complete all as specified and directed. (Note : WPC will be measured and paid separately under relevant item)
M&L for applying three coats of white wash on wall surface including preparation of new plastered surface complete all as specified and directed.
M&L for applying three coats of white wash on surface of ceiling including preparation of new plastered surface complete all as specified and directed.
M&L for applying two coats of cement based paint over a coat of alkali resistance primer on newly plastered surface of walls including preparation of surface complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide primer after preparation of new steel surfaces of any description over 10cm width or girth complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide primer after preparation of new plaster surfaces of wall of any description over 10cm width or girth complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide primer after preparation of new steel surfaces of any description not exceeding 10cm width or girth complete all as specified and directed.
S&F of 15mm dia bib tap, fancy type, cast copper alloy with crutch or butterfly handles, screwed down, screwed for iron pipe or for brass ferule, chromium plated with long screw type fixed complete all as specified and directed.
S&F of 15 mm bore angular stop valve, fancy type, chromium plated , cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F of 15mm dia pillar tap, fancy tpype, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with letter 'HOT' or 'COLD' with long screwed shanks & fly nuts, screwed for iron pipes complete all as specified and directed.
S&F of shelf of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 300gms) complete all as specified and directed.
S&F of 15 mm dia PVC connection pipe of length 450 mm with PTMT nuts complete all as specified and directed.
S&F of 20mm dia gun metal gate valve with iron wheel head screwed both ends for iron pipes or for unions pipes, fixed and including taking down old unserviceable gate valve complete all as specified and directed.
M&L for cutting existing steel tubing for alterations or additions (each cut measured) in 50 mm bore pipe line complete all as specified and directed.
S&F of 1000 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multi layer (three layer), ISI Marked hoisted and fixed in position with cover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection complete all as specified in SSR Part-I and directed.
S&F for vitreous china squatting pan 'Orissa' pattern, size 580x440mm white, with integral foot rests with P or S trap (excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti-syphonage pipe etc complete including making good to floors with PCC bedding (1:4:8) type D2 using 40mm nominal brick ballast and connection to trap with cement mortar, and making good to floor complete all as specified and directed.
S&F for Vitreous china urinals, half stall type (excluding flushing cistern but including flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe completeall as specified and as directed.
S&F of vitreous china wash basin, white, flat back, size 550 X 400 mm, excluding taps, chain and plug and porcelain stopper but including waste pipe, brackets and cutting for and pinning in ends of brackets or erecting stand acomplete all as specified and directed.
S&F of 10 Ltrs capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with all internal accessories and fixed to wall and jam nuts on both sides, PVC flush pipe 32mm dia suitable for low level cistern fixed properly to inlet of WC and making good to disturbed surfaces of wall or floor complete all as specified and directed.
S&F of 125mm size brass chromium plated shower roses with arms, swivel joints, including fixing to steel pipe or union complete all as specified and directed.
S&F of brass chromium plated tubular towel rail, 20mm dia, D-type, 60cm long between flanges complete all as specified and directed.
S&F of 20mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, concealed joint with CPVC adhesive taflon tape complete to walls and ceilings or laid in floors including all connected brass CPVC fittings and cutting grooves, filled with Cement mortar(1:6) complete all as specified and as directed.
S&F of 25mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, concealed joint with CPVC adhesive taflon tape complete to walls and ceilings or laid in floors including all connected brass CPVC fittings and cutting grooves, filled with Cement mortar(1:6) complete all as specified and as directed.
S&F of 20mm dia tubes (medium grade) galvanised iron, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) after complete all as specified and directed.
S&F for 200 mm dia reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed.
S&F for 100mm bore sand cast iron soil, waste and vent pipes in any length with or without ears with cement joints, laid in floor complete all as specified and directed.
S&F of 100 mm dia Cast Iron bends (any radius) diminishing piece or tapers (larger bore measured) complete all as specified and directed.
S&F of 100mm dia CI branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access door complete all as specified and directed.
S&F for 75mm bore sand cast iron soil, waste and vent pipes in any length with or without ears with cement joints, laid in trenches or in floors complete all as specified and directed.
S&F for 75mm bore sand cast iron soil, waste and vent pipes in any length with or without ears with cement joints, fixed to walls complete all as specified and directed.
S&F of 75mm dia Cast Iron bends (any radius) diminishing piece or tapers (larger bore measured) complete all as specified and directed.
S&F of 75mm dia Cast Iron bends (any radius) diminishing piece or tapers (larger bore measured) with oval access door complete all as specified and directed.
S&F of 200 mm dia reinforced concrete bends laid and jointed complete all as specified and directed.
M&L for PCC (1:3:4) type C2 (using 40mm graded crushed stone aggregate) as in concrete bed to drain pipe 200 mm bore including packing under and haunching against the side of pipe after they are laid and tested complete all as specified and directed.
S&F for 75mm dia cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
S&F for cast iron 'P’ or 'S' trap of 100mm bore complete complete all as specified and directed.
S&F for 75 mm cast iron cowls complete all as specified and directed.
S&F for 100 mm bore cast iron swan neck (or off-sets) upto 152 mm projection complete all as specified and directed.
S&F of salt glazed stone ware gully trap of size 150mmX100mm square or round mouthed type including jointing to drain pipe in CM (1:1), type 'P' complete all as specified and directed.
S&F of 03 seater benches of following specifications:- Frame -heavy duty cast iron Legs & hand rest - heavy duty cast iron. Back and bottom support - FRP/PVC sheet total length and height - 160-165cm/85cm Seat height and depth -40cm & 45cm Support size- 155-160cm x 7.5cm x 2 cm No of support - 8 to 10 Load Capacity - 300 Kg Note - PCC for grouting shall be measured and paid seperately under relevant item
S&F flexello cast iron shock absorbing trolley wheel (WCI Series), minimum load capacity of wheel 300 Kg, dia of wheel 100mm, width 38mm and dia of bore 15mm fixed with iron door gate with all necessary fittings complete all as specified and directed.
S&F inrerroll roller track, heavy duty, 50mm dia, 51.30mm width, 962mm x 74mm constructed from galvanized steel, incorporating diameter dual ball race roller pitched at 104mm, the roller track carry a maximum load of 40Kg per roller fixed to RCC/Brick wall complete all as specified and directed.
M&L for point wiring complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of modular top cover , blanking plate as per numbers of switch modules, modular switches, sockets, fan regulators, red colour indicator, blank plates etc as approved coloures modular accessories of suitable modules and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces by applying white/colour wash/distemper as applicable after applying of putty for smooth finish surface complete all as specified and directed for the following:- (Note:- (i) All necessary accessories such as modular box, top cover plate, blank plate, MS box, screws, washers etc are to be used of same make/brand only in relevant items. (ii) Cutting & chasing of wall for point wiring at any height shall be done and cost of the same deemed to be including with quoted rate.)
One light point controlled by one switch .
One fan point controlled by one switch and one regulator.
One 3/5 pin 6 amps socket point controlled by one 5/6 amps switch on independent board .
One 3/5 pin 6 amps socket point controlled by one 5/6 amps switch on same board .
All as per Item No.115.00 here-in-before but point wiring with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmm complete all as specified and directed for the following :-
One 5/6 pin 6/16 amps socket outlet point controlled by one 15/16 amps switch on independent board.
S&F of socket out let, flush type, 2 in 1, 3/5 pin, 5/6 Amps, 240 volts, AC, ISI marked complete all as specified and directed.
S&F of switch piano flush button single pole one way 15/16 amp 240 volts, AC, ISI marked complete all as specified and directed.
S&F of socket out let, flush type, 2 in 1, 3/5 pin, 5/6 and15/16 Amps, 240 volts, AC, ISI marked complete all as specified and directed.
S&F of switch piano flush button single pole, one way, 5/6 amp, 240 volts, AC, ISI marked complete all as specified and directed.
S&F of angle lamp holder, insulated body with back plate for batten fittings complete all as specified and directed.
S&F of ceiling rose , three terminal, PVC/polycarbonate body, ISI marked complete all as specified and directed.
S&F of decorative type surface mounted 1X20 watts LED light fitting with LED lamps including fixing arrangements at any height with nuts, screws and washers and connected to ceiling rose and connecting up with and including three core sheathed flexible copper conductor cable of required size complete all as specified and directed. (Make: PHILIPS Cat No. BN170C LED 205-6500 PSU L120/ SURYA Cat No. SLE BT 20 G1/ HAVELLS Cat No. LUMINILE+ BS 20W LED 830 SPCSS or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
S&F of 60 Watt LED street light, 230 volts, AC, Out door type with thermal management in multiple optics and equiped with IP-66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply, fabricated and fixing of street light bracket made out of GI pipe 40mm dia medium grade bent to shape of 1.2 mtr long as directed including clamps made out of 40 mm x 6 mm flat iron for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
S&F of powder coated sheet metal enclosure acrylic door 240 volts AC,SPN distribution board 4 way for flush mounting with 200 amps copper busbar, neutral bar, earth bar suitable for MCB incomer of rating upto 200 Amps, MCB SPN/DP and MCB SP, 10KA as outgoing and complete connecting cable links with top and bottom removable gland plates with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat complete all as specified and as directed. (Make:- Legrand cat No. 5076 20 4 way /L&T Cat No. DBSPN004GDor equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
S&F of MCB, SP, 6 Amps to 32 Amps , 'C' series, 240 Volt, 10KA, 50 Hz, ISI marked complete all as specified and directed
S&F of MCB, SPN, 32 Amps, 10 KA, 'C' series, AC, 240 volts, ISI marked complete all as specified and directed.
M&L for earthing with glavanised steel earth plate electrode of size 60cmX60cmX6mm thick buried directly in ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel using GI earth strip 32x6 mm as earthing lead as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) pit, funnel, 20mm dia GI medium grade watering pipe , 40mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A-1 duly reinforced with 8mm dia TMT bar @150c/c both ways, one lifting handle made out of 10mm dia TMT bar 250 mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick complete all as specified and directed. (Note: Galvanised iron strip of 32x6mm upto 7.5m long including testing is deemed to be included with quoted rate).
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed or any other indicated situation for loop earthing etc as required 20X4 mm GI strip complete all as specified and directed.
S&F of heavy duty type exhaust fans AC single phase 230/240 V of size 300 mm sweep, 900 RPM with louver and necessary connection, testing including cutting the existing wall surfaces of brick/stone masonry and making the hole of any height for fixing the exhaust fan with nuts, bolts and washers after grouting in PCC including mild steel jalli and wooden frame for avoid insects complete all as specified and directed. (Make : Havells model No Turbo Force SP 300mm-900RPM or equivalent model of Crompton Greaves as approved).
S&F of 1100 Volts grade heavy duty cable PVC insulated copper conductor round flexible and over all PVC insulated in street light connection from pole junction box at bottom to street light fixed on 9 mtr long swaged pole by making two holes with welding machine for inserting cable of size 1.5 Sqmm 3 core multistranded including making all necessary connection all as specified.
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 10 sqmm, 4 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required).
M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed. (Note: Only punned down volume of sand to be measured).
M&L for brick covering with width equal to length of brick as protection to cable with well burnt sub class ‘B’ bricks of size 250mm x 125mm x 75mm laid dry flat complete all as specified and directed.
S&F for aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
S&F for air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed.
S&F of test point termination block made of gun metal or phospherous bronze size 75mmX75mmX25mm drilled and screwed including 3 Nos, 8mm dia 25mm long hex head screw complete all as specified and directed.
M&L for GI pipe 50mm dia (light grade) complete with all fittings in trenches, road/culvert crossing, floors, on roof, on pole for cable protection complete all as specified and directed.
M&L for GI pipe 40mm dia (light grade) complete with all fittings in trenches, road/culvert crossing, floors, on roof, on pole for cable protection complete all as specified and directed.
Boaring holes horizontally under road without damaging the surface of road(minimum 1.0 Mtr bellow the road surface) with the help of GI tubing of dia not exceeding 100 mm dia for passing of UG cable all as specified and as directed.
Supply, fixing and commissioning water heater storage type, eletric operated, capacity 25 Litres, BEE 5 Star rated complete with all connected accessories suitable for AC supply, 240 volts, 50 Hz including connecting with water supply pipe line and all water and electrical connection complete with necessary PVC connection pipe all as specified and directed. (Make: Crompton Model No. Arno Neo 25-L5 Star, Bajaj Model No. Montage 25L 5 Star or equivalent model/make as Appx 'A' of PS)
S&F of CRCA kiosk box 2mm thick suitable for three phase 415 volts AC supply with 04 Nos aluminium bus bar rating 63 amps with one No MCB 10 Amps , SP having size 350X250X150mm complete including making fixing arrangement with 9 mtr long swaged pole with flat iron clamp complete all as specified and directed. (Make- Sintex/Star electric Eng Co./Universal switch gear control or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
M&L for supply, erection and commissioning of steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts and screwes as specified type LT type 410 SP-31, (9m long) including placing at new location complete all as directed by Engineer-in-charge. (Note : Excavation, earth work and concrete work are not included in quoted rate by the Contractor and the same will be measured and paid seperately)
NANDY ENTERPRISE
M/S KARTICK CHANDRA CHAKRABORTY
SENCO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .