Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.4 LAccepted-AOC 578 AVAS VIKAS JANAKPURI B IZATNAGAR BAREILLY 243122 UP | BAREILLY | UTTAR PRADESH | 243122 | L1 | Accepted-AOC AOC | |
| 2 | L2₹30.9 L+₹96,289 (3.22%)Rejected-Finance R O 89 PRABHAT NAGAR NEAR RAM JANKI MANDIR BAREILLY 243122 UP | BAREILLY | UTTAR PRADESH | 243122 | L2 | Rejected-Finance Being High Bid | |
| 3 | L3₹31.9 L+₹2.0 L (6.52%)Rejected-Finance C 247 1 RAJINDRA NAGAR BAREILLY 243122 UP | BAREILLY | UTTAR PRADESH | 243122 | L3 | Rejected-Finance Being High Bid | |
| 4 | L4₹33.4 L+₹3.4 L (11.5%)Rejected-Finance 232 1 D SHIVLOK KANKARKHERA DISTT MEERUT UP PIN 250001 | MEERUT | MEERUT | UP | 250001 | L4 | Rejected-Finance Being High Bid | |
| 5 | L5₹35.4 L+₹5.5 L (18.3%)Rejected-Finance 160 PREM NAGAR BAREILLY | L5 | Rejected-Finance Being High Bid |
Tender Value
₹53.2 L
EMD Value
₹1.0 L
Closing Date
14 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Bareilly
HQ, CWE, MES, Station Road, Bareilly
CWE BLY/GE (E) /73 OF 2023- 2024 SPECIAL REPAIRS TO OTM ACCN BLDG NO T-146 OF ENGR REGT UNDER GE (EAST) BAREILLY
2024_MES_636395_1
8200/B/785/E8
Open Tender
Civil Works
Item Rate
180 days
GE (East) Bareilly
As per NIT
6 documents required · 6 mandatory
₹1,000
GE (East) Bareilly
₹1.0 L
Yes
23 Mar 2024
8 Jan 2024
16 Feb 2024
8 Jan 2024
14 Feb 2024
29 Jan 2024
Amount
Taking down cement plaster including racking out joints, hacking for key&scrubbing down with water etc complete all as specified and directed
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
Dismantling of stone slabs and tiles of any description or thickness in floors ,aprons laid,bedded and jointed in any mortar etc all as specified and directed.
Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness below or above ground level complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
Demolition of concrete of any description and in any position not otherwise specifically provided for
Excavating in trenches n. exc. 1.5 m wide, and n.exc. 1.5 m in depth for foundation etc. n.exc. 10 sqm on plan and n. exc. 1.5 mtr in depth and getting out hard/ dense soil
Taking down chowkats or frames not exceeding 1.5 Sqm each with shutter (without taking off shutter from the frame) and removing to store complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each with shutter (without taking off shutter from the frame) and removing to store complete all as specified and directed by Engineer-in-Charge.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories)
Taking up or down15 mm steel tubing and connections including cleaning for refixing or removal complete all as specified and directed by Engr-in-Charge
Taking up or down20 mm steel tubing and connections including cleaning for refixing or removal complete all as specified and directed by Engr-in-Charge
M & L for dismantling water tanks exc 500 but not exc 1000 Litres, and removing to store complete all as specified and as directed.
M&L 15mm thick rendering in cement mortar 1:4 to brick masonry wall surfaces or on other than fair faces of brick wall surfaces finished fair & even without using extra cement for fixing tiles etc complete all as specified and directed .
M & L 25 mm thick PCC 1:2:4 type B-1, using 25 mm graded stone aggregate as in floors to receive surface of tiles complete all as specified and directed.
M&L screed bed or bedding layer of mortar, 15 mm thick, in cement mortar 1:6, for laying floor finishes/tiles complete all as specified and directed.
M&L screed bed or bedding layer of mortar, 20 mm thick, in cement mortar 1:6, for laying floor finishes/tiles complete all as specified and directed.
M&L Non- skid coloured ceramic tiles 9 to 10mm thick (square / rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile complete all as specified and directed.
M & L 9 to 10 mm thick glazed coloured ceramic tiles ( square/ rectangular) with border of size 300x600mm, as in vertical surfaces such as skirting or dado set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles complete all as specified and directed.
M&L Machine cut kota stone slab flooring 20-25 mm thick over 20 mm thick screed bed laid in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing and treating the surface incl complete all as specified and directed (Note- Screed bed paid seprately)
M&L Machine cut kota stone 20-25 mm thick in riser of steps,skirting,dado and pillar over 20 mm thick screed bed laid in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab complete all as specified and directed (Note- Screed bed paid seprately)
M&L Providing edge moulding to 20-25 mm thick stone of counters vanities etc. including machine polishing to edge to give high gloss finish etc. complete all as specified and directed
M&L 18-20 mm thick Granite of black colour (table rubbed and polished) in win dow-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite with full round bull nosing edging complete all as spd as directed
M & L for 75mm thick PCC 1:3:6 , type C-2 using 40 mm graded stone aggregate as in plinth protection laid in slope in 1:30 in alternative bays not exceeding 3 mtr in length. Exposed surfaces finished even and smooth without using extra cement including raking out joints between panel to panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in 1:3 complete all as specified and directed .
M&L 75 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base floor/pavings complete all as specified and directed
M&L sand filling under floors or in foundation including watering and consolidation complete all as specified and directed
M&L machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness ,M-35 grade complete all as specified and directed.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line,level and curvature ,jointed with cement mortar 1:3 (1 cement:3 coarse sand) ,including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm ) including making drainage opening wherever required complete all as specified and directed
M&L for reinforced cement concrete 1:1.5:3 type A-1 (using 20 mm graded stone aggregate ) ( nominal mix ) as in slabs supported on wall ,landing, balconies ,shelves and like including bonding agent ,complete all as specified and directed (reinforcement to be measured &paid under respective items )
M&L form work to chajja, slab ,weather shade, troughs and similar items including edges for rough finished surfaces of concrete flat, complete all as specified and directed
M&L form work to edges of concrete flats, treads, breaks in floors window cill, concrete railing opening in conc wall , floor and roof n.exc 20cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n.exc 20cm wide for rough finished surfaces of concrete, complete all as specified and directed.
Supply and fix TMT bars, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) but not less than 0.9 mm dia conforming to Fe-410 - 0, complete all as specified and directed
M&L PCC 1:5:10 type E-2 (40 mm graded stone aggregate) as sunken base of floor fillings complete all as specified and directed
S&F 32 mm dia GI pipe ,medium grade as in spout pipe in suken floor complete all as specified and directed
M&L for brick work with fly ash bricks, straight or curved on plan exc. 6 m mean radius, built in CM (1:6) complete all as specified and directed
M&L rendering 15 mm thick in CM 1:6 on brick masonry surfaces or on other than fair faces of brick masonry finished even and smooth witout using extra cement complete all as specified and directed.
M&L 15mm thick rendering in cement mortar 1:4 to brick masonry wall surfaces or on other than fair faces of brick masonary finished even and smooth without using extra cement with using water proofing liquid @ 0.15 Ltr per bag of cement complete all as specified and directed.
M&L rendering 10 mm thick in CM 1:4 as on concerete surface on ceilings finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for applying cement slurry over existing roof surface @ 3 kg/Sqm incl mix with water proofing liquid @0.15 Ltr per 50 kg cement bags as per manufactureres instructions complete all as spd and directed
M &L for PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregrate laid over roof slab after applying cement slurry for filling undulationations finished even and smooth without using extra cement complete all as spd and directed.
M&L screed bed or bedding layer of mortar, 15 mm thick, in cement mortar 1:4, over RCC roof slabs for laying water proofing treatment mixed with using water proofing liquid @ 150 ml per bag of cement complete all as specified and directed by Engineer-in-Charge. (Note : Water proofing liquid shall be measured and paid separately)
supply Integral water proofing Liquid complete all as specified and directed
S&F Pressed steel frames 125x60 mm for doors with one or more rebates including necessary fixing lugs ,hinges,lock strike plate ,etc,complete ,as specified ,complete all as spd as directed.
S&F 30 mm Plain,framed,panelled shutters(any number of panels) 2nd class HW with panels of timber flat on both sides (feather edged),or of veenered particle board medium density ,wood particle board with comercial face veeners.complete all as specified and directed
S&F 30mm thick factory made glazed and skeleton door shutters open rebated of second class hard wood rail and styles(Hollock), prepared to receive glass/gauge etc without sash bars, edges of framing plain cham-fered or rounded, mitred and rebated sash bars, any numbers The size of rails & style as specified in SSR Part-I (2009) section 8 and as per IS-1003(Part-I) kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and directed by Engineer-in-Charge. (Note :- S & F Glass/gauge shall be measured and paid for separately)
S & F 150 mm long Floor door stopper of aluminium alloy body and tongue with hard drawn steel spring. fixed in floor complete all as spd and directed.
S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm thick single side prelam PVC sheet used instead of Plain colour PVC sheet , suppling & fixing in opening as per specification & drawing.
S&F 30 mm thick factory made both side Prelam PVC sheet used instead of Plain colour PVC sheet. Stile and rails feathered at edges consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded palin colour PVC `C' channel heaving a Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F mild steel window grills box type framed work as in window guard bars, grills or forged into spikes, framed balusters, walkway railing and similar work including welding complete FE-290 grade E-165 all as specified and directed.
S&F Steel windows with pressed steel frame (size 95x45x1.25 mm) side hung shutter including box type hinges with steel handle ,and steel peg steel complete with glazed openable shutter with glazing bar (open out side) and wire gauzed openable shutter without glazed bar (open in side) dovetailed or welded complete all as spd and directed and all as per drg no TD/088 dt 07 Jun 2002 Note:-(i) Two shutter ie wire gauged and glazed shall be fixed in one composite frame and both shutter shall be measured as one unit (ii) Rate for filling of PCC in frame deemed to be included in quoted rate (iii0 MS grill shall be measured and paid seprately under relevant item of schedule
S&F steel ventilators fixed type ,with glazing bars complete welded including one shop coat of Red oxide Zinc chromate primer complete all as specified and directed by Engineer-inCharge (Note:- Glass shall be measured and paid seprately)
M&L for 3mm thick sheet glass ordinary quality and glazing with oil putty in squares not exc. 0.5 Sqm in each pane complete all as specified and directed
M&L Hacking out old broken glass (any thickness, size, quality or description) from wooden frames and fixing 3 mm thick sheet glass ordinary quality and glazing with oil putty in squares not exc. 0.5 sqm in each pane complete all as specified and directed
S&F galvanised steel wire cloth ,0.56 mm nominal dia of wire and average with of aperture 1.18 mm and fixed with galvanised steel wire staples complete all as specified and directed by Engineer-in charge
S & F 300 mm long Aluminium, anodised, barrel tower bolts of extruded section and fixed all as specified and directed
S & F 150 mm thick Aluminium, anodised, barrel tower bolts of extruded section and fixed
S&F 150mm size aluminium handles, cast type anodised completed all as specified and directed.
S&F 100 mm size butt hinges medium weight colled rolled mild steel complete all as specified and directed by Engineer-in-Charge.
S&F 300mm size ordinary mild steel , rat tailed rod pattern spring including roller and roller plate welded to mild steel frame.fixed in repair complete all as specified and directed
S&F 300 mm long aluminium sliding door bolts plate type with bright bolt not less than 16 mm dia with and including a minimum of 6 bolts and nuts, 04 Nos on bolt plate and 02 Nos on staple plate and fix complete all as specified and directed
S&F 1000 litres, rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top), hoisted and fixed in position complete all as specified and directed by Engineer-in-Charge.
S&F 20mm bore ball brass valve high pressure with polythene float and fly nut complete, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge.
S&F15 mm dia steel water tubing galvanized medium grade concealed in all type wall with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed by Engineer-in-Charge
S&F 20 mm dia steel water tubing, galvanized, medium grade concealed in all type wall with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed by Engineer-in-Charge
S&F in repairs brass chromium plated wall mixer 3 in 1, 15mm for mixing hot & cold water screwd down three joints to steel pipes or unions and plugging and screwed to walls complete all as specified and as directed
S & F in repair fancy type 125mm size square brass CP shower rose all as specified.
S&F in repairs 15 mm dia bib tap fancy type chromium plated with flange quarter turn complete all as specified as directed.
S&F in repair fancy type chromium plated brass two way bib cock suitable for 15mm bore pipe complete all as specified and directed.
S&F in repair stainless steel of grade tubular towel ring including apair of CP brass bracket complete all as specified.
S&F in repairs 15mm bore PVC connections, with PTMT nuts of length 450mm complete all as specified and directed.
S&F in repair fancy type brass chromium plated soap dish of 160x160x90 mm , complete all as specified.
S&F in repair fancy type chromium plated brass angle valve type suitable for 15mm bore pipe complete all as specified.
S & F in repair fancy type sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with CP brackrt gaurd and railling 60 cm long complete all as specified.
S&F 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed
S&F in repair 15 mm dia fancy type stop cock , chromium plated with long shank and cup (conncelaed type)for iron pipe or for unions and fixed.
S&F in repair vitreous china squatting pan of orrissa pattern long pan size 580 x 440 mm white with "P"or "S" trap size 100 mm dia front or back inlet and integral foot rest any pattern (excluding flushing cistern and flush pipe)water closet squatt pattern complete including provn of lime concrete bedding complete all as specified.
S&F in repair PVC low level flushing cistern 10 litres, valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, flushing pipe complete all as specified and directed.
S&F Vitreous China counter top oval type coloured wash basin suitable size including swan neck pillar taps with bottle trap but including waste pipe fixing on counter with stainless steel brackets complete all as spd
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified and directed
S&F in repair PVC (SWR) multifloor trap with grating including jointing with solvent cement floor trap 100 mm dia outlet plain with grating including jointing to waste pipe fixed in cement concrete 1:2:4, type B-1 complete all as specified and directed.
S&F PVC (SWR) 75 mm bore pipes single socketed in any length with rubber ring joints fixed to wall and floor with neceassary fitting complete all as specified and directed.
S&F PVC (SWR) 110mm bore pipes single socketed in any length with rubber ring joints fixed to wall and floor with neceassary fitting complete all as specified and directed.
S&F PVC (SWR) 110mm bore bends any radius complete all as specified and directed.
S&F PVC (SWR) 75mm bore bends any radius complete all as specified and directed.
S&F PVC (SWR) 75 mm bore junction single (Single 'T') equal or unequal with access door complete all as specified and directed.
S&F PVC (SWR) 110 mm bore junction single (Single 'T') equal or unequal with access door complete all as specified and directed.
S&F in repair 20 mm dia stainless steel 1.0 mm thick fancy type droppery rod with decorative design matching brackets as approved and knobs (lattu) or end bracket as required incl fitting with 80 mm long SS screw with 75 mm long wooden gitty of appropriate c/s in each end & intermediate support complete all as specified and as directed
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confirming Fe-410-W(Gde E-250)quality-A complete all as specified and directed
S&F Pre-coated galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 mpa as in roof covering / cladding to wall, fixed with self tapping screws asspecified and directed
M & L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, Chajja ( up to IInd floor) etc making good, cutting exc 10cm and not exc 40cm girth in Stone concrete block or slab walls complete all as specified and as directed.
Dismantling of concrete by chiseling from RCC members like column , beam, parapet facia, chajja, ceiling,etc exposingthe reinforcement without disturbing the reinforcement free from rust by sand blasting/using chemical , apply a coat of rustolin to remove rust and acralic polymer on old rusted reinforcement proving at places addl reinforcement welding with existing reinforcement as directed wherever required binding RCC 50 mmx50 mm (10 mm gauge welded mesh ) & tack , securing with clips / blinding wire, welding & provision guniting pressure 2.2 to 2.5 kg /sqm with admixer 1 cement 3.5 of sand of thickness 25 to 40 mm including stripping floating with wooden strippers for proper dimension control neccssary form work & scaffolding up to three storey and including height of head room complete surface of guniting to be finished fair with 10 mm thick plaster in cement mortar 1:4 with water proofing compound @3% by weight of cement and construction fibre as per manufacturer instruction cleaning & removing of waste meterial etc as dirply two coat of Water proofing liquid at interval of 8 hours cure for the surfaces complete all as specified and directed
S&F 0.71 mm thick Plain Aluminium sheeting Alloy 31000 H4 in stepped flashing (measured as the minimum rectangle from which the pieces can be cut) complete all as spd and directed.
M&L preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chrome primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new or previously untreated wooden or wood based surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over and including one coat of pink primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old painted wooden or wood based surfaces of any description n.exc 10 cm in width or girth when unconnected with other painting or when painted in a diferent tint and applying one coat of synthetic enamel paint over and including one coat of pink primer complete all as specified and directed.
M&L for complete removal of existing treatment on wall by scrapping with mechanical sander (having mechanical vaccum mechanism ) with sanding pad of appropriate grit to make surface clean ,free from dust ,loose paint etc by skilled labour and applying two coat OBD on wall with airless electric sprayers over a coat of primer applied using airless electric sprayer over two coat of wall care putty of 1mm thickness complete all as specified and directed
M&L for applying of two coat OBD on newly plastered surface of wall with airless electric sprayers over a coat of primer applied using airless electric sprayers over two coat of wall care putty of 1 mm thickness prepared and sanded with electrically operated sanding machine complete all as specified and directed
M&L for preparation of newly plastered surface of walls and applying two coats of Dust Resistant and Anti Algal weather proof exterior emulsion paints over a one coat of wall care putty complete all as specified and directed
M&L for complete removal of existing treatment on surfaces of walls including cleaning the surface throughly by using wire brushes and removing use materials from the surface and applying two coats of Dust Resistant and Anti Algal weather proof exterior emulsion paints over a one coat of wall care putty complete all as specified and directed
M&L for preparing newly plastered surfaces and applying three coats of white wash on ceiling complete all as specified and directed.
M&L complete removal of existing treatment on ceiling,etc including cleaning of any mortar drops ,fungus efflorescent salts etc and prepration of old plastered surface and applying two coat of white wash complete all as spd and directed.
Taking down copper/aluminum point wiring complete including fixture and fitting such as switches, ceiling roses, pendants, regulators, sockets, light fittings, holders etc and removing the items from site to store for taking credit (credit for above items should be made as per conditions separately ) and making good disturbed surfaces to match with the existing surfaces of walls, floors etc complete all as specified and directed.
Taking down main switch / MCB DBs including MCCBs etc of any size and removing the items from site to store for taking credit (credit for above items should be made as per conditions separately ) and making good disturbed surfaces to match with the existing surfaces of wall, floors etc complete all as specified and directed.
Taking down ceiling/exhaust fan and disconnecting, removing to store for keeping in safe custody for BER Board or rehanging etc after some minor repair complete all as specified and directed.
Taking down electric geyser and disconnecting , removing to store for keeping in safe custody for refixing etc complete all as specified and dircted and refixing the same as its original postion.
Taking down submainwiring/service cable including earth wire and removing from site to store for taking credit (credit for above items should be made as per conditions separately ) and making good disturbed surfaces to match with the existing surfaces of walls, floors complete all as specified and directed.
M & L for point wiring with 1.5 sqmm cable PVC unsheathed and insulated copper multistranded conductor FRLS 1100 Volts grade cable ( red colour cable to be used for live connection and black colour cable to be used for neutral connection ) controlled by one way switch drown through and including PVC concealed conduit with all accessories including 1.5 sqmm copper multistrand conductor FRLS 1100 Volts grade unsheathed PVC insulated ( green colour ) continuity earth wire connected to common earth dolly and sunk cast pressed steel terminal box made out of MS sheet 1.25 mm thick for mounting of fittings like switch , socket and fan regulator with 3 mm thick hylum laminated sheet cover incl cutting Chases pinning in, for concealed conduit wiring and making goods of disturbed surface not exc 15 cm girth complete all as specified and as directed following for one light point/fan/Exh fan /bell point controlled by one way switch.
All as per item No.110 herein before but One 3 pin socket oultel 5 Amp on the same board with other switch
All as per item No.110 herein before but One 3 pin socket oultel 5 Amp independent
All as per item No.110 herein before but one light point controlled by two way switch
All as per item no.110 herein before but 2.5 Sqmm PVC insulated sheathed cable and 2.5 Sqmm cable for earth wire for one 5 pin socket outlet 15 Amps
S&F switch piano flush type single pole one way 5 Amps
S&F Switch Piano flush type single pole one way 15 Amps
S&F Switch Piano flush type single pole two way 15 Amps
S&F Socket outlet 2 in 1, 3 pin 5 Amp flush type
S&F socket outlet 2 in 1, 3 pin 5 Amp and 15 Amps
S&F Lamp holder, PVC/Polycarbonate type with back plate for batten fittings
S&F rechageable Lamp LED 15 Watt 230 Volt
S&F ceiling rose, 3 terminals, PVC polycarbonate isolated body.
S&F in repairs LED bulk head luminaire hexafit 10 watt LED environmental friendly , ultra modern , energy saving , surface mounted ,decorative hexagonal bulk head back lit LED luminaries comprising of high brrightness LED complete all as specified & as directed.
S&F in repairs surface and wall mounted LED Tube light batten with polycarbonate housing and integtated eletrinic driver fittings 20 Watt ( T-8 ), 4' including connecting up with 3 core flexible copper conductor cable of suitable size complete all as specified & as directed.
S&F in repairs surface and wall mounted LED Tube light batten with polycarbonate housing and integtated eletrinic driver fittings 10 Watt ( T-8 ), 2' including connecting up with 3 core flexible copper conductor cable of suitable size complete all as specified & as directed.
S&F in repairs new generation LED building security light fitting 35 Watt 230 Volts AC out door type energy saving and envrionmental friendly long life LED street light made out of with high pressure die cast aluminium housing with high efficiency LED asc lighting source and lens embeded PC cover having bottom opening seperate driver component with IP 66 protection and impact resistance of IK08 including electric conection complete all as specified & directed.
S & F exhaust fan AC single phase, metallic body , heavy duty, 230/240 Volts, of size 300 mm sweep with louvers including making suitable size hole in the wall for air flow and grouting of nuts & bolts and washers including making connection with three core copper cable of size not less than 1.5 sqmm from ceiling rose complete all as specified & directed.
S&F in repairs round shape 10 watt recessed mounted LED down lighter with white powder coated alu housing with integrated electrinic driver THD<10% 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & as approved by GE.
Supply and fixing ceiling fans 1200 mm sweep complete with blades, down rod , electronic regulator and accessories, 230 V, 25 watt to 36 watt , min air delivery 210 CFM with service value 6.00 BEE(Five star ) rated brushless direct current motor (BLDC) and marking the serial MES fan Nos etc inclding electric connection with three core flexible PVC insulated copper conductor multistranded cable 1.0 sqmm complete all as specified and directed.
Hanging only geyser after cleaning & making functional by replacement of thermostat ,NRV , angle valve, heating element , inner tank( if required) , hot and cold pipe 450 mm long braided hose required replacement and connection etc. painting and remarking the serial MES nos etc complete including electric connection with three core flexible PVC insulated copper conductor multistranded white in clour 2.5 sqmm cable including plug top complete all as specified and as directed.
(a) Thermostat
(c) Angle valve brass CP
(d) Heating element 2000W
(e) Hot and Colt Pipe
Hanging only geyser after cleaning & making functional by replacement of thermostat ,NRV , angle valve, heating element , inner tank( if required) , hot and cold pipe 450 mm long braided hose required replacement and connection etc. painting and remarking the serial MES Nos etc complte including electric connection with three core flexibel PVC insulated copper conductor multistandared white in colour 2.5sqmm cable including plug top complete all as specified and as directed.
S & F GI bracket made out from GI pipe 32/25mm dia, 1.2 mtr long bend to shape including 02 Nos 25x4 mm MS clamps,nuts, bolts washers fixed on wall & including painting etc complete.
S&F sheet metal enclousers (DBs) when MCBs to be used 4 way double door with 200 Amps rated bus bar.
S&F sheet metal enclousers (DBs) when MCBs to be used 8 way double door with 200 Amps rated bus bar.
S&F sheet metal enclousers (DBs) when MCBs to be used Vertical three phase and neutral (VTPN) 6 way double door with 200 Amps rated bus bar with MCCB incommer .
Supply and fix MCCBs 415V, 16 KA, 3 Pole 125 -160 Amps all as specified and as directed.
S&F MCB single phase and neutral 40-63A, 240Volt C- curve complete all as specified and directed.
S&F MCB single pole 40A, 240Volt B- curve complete all as specified and directed.
S&F MCB SP 6A-32A, 240Volt B curve complete all as specified and directed.
S&F sub main wiring with 2 run FRLS PVC insulated and unsheathed multistranded copper condutor of nominal cross section area 2.5 sqmm alongwith one run of FRLS PVC insulated and unsheathed multistranded copper conductor of nominal cross secrtional area 2.5 sqmm as earth contuinity conductor drawn through in and including PVC conduit complete all as specified and as directed.
S&F sub main wiring with 2 run FRLS PVC insulated and unsheathed multistranded copper condutor of nominal cross section area 4.0 sqmm alongwith one run of FRLS PVC insulated and unsheathed multistranded copper conductor of nominal cross secrtional area 4.0 sqmm as earth contuinity conductor drawn through in and including PVC conduit complete all as specified and as directed.
S&F sub main wiring with 2 run FRLS PVC insulated and unsheathed multistranded copper condutor of nominal cross section area 6.0 sqmm alongwith one run of FRLS PVC insulated and unsheathed multistranded copper conductor of nominal cross secrtional area 6.0 sqmm as earth contuinity conductor drawn through in and including PVC conduit complete all as specified and as directed.
Taking down UNSV LT UG cable of any size
Excacvation in trenches not exc 1.5 mtr wide and n exc 1.5 mtr in depth and getting out in soft/loose for laying cables complete all as specified.
Returning, filling in including spreading, levelling, watering and well ramming in layers n exc 25 cm in soft/loose soil complete all as specified.
Removing excavated material n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point
Supply & laying sub class B bricks, well burnt , laid wirdth wise along the length of cable laid in trench over sand cushion laid for cable protection, complete as specified and directed.
Material and labour for river washed and sreened, dry sand for filling in trench below and around the under ground cable for cushioning of cable etc, complete all as specified.
Boring of holes under road or cutting the road/path/pavement/hard standing or any other situation by mannual means for 25mm bore GI pipe for crossing the cable and making good both the ends all as specified and directed at site. Note :- GI pipe shall be measured and paid separately under respective item.
Supply & fix tube 40 mm bore light grade GI with all fittings for cable protection for road crossing/ culvert/ path/ on wall/ floor/ pole/ across the road/path/culverts or laid in floor.
Supply, Laying and testing cable XLPE insulated, screened, PVC bedded,GI steel strip or wire armoured, electric power cable ( heavy duty ), 1100Volts with stranded aluminium conductor of size 70 sqmm 3.5 core
M&L for earthling complete with Galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directrly in ground (earth pit not less than 2.25 mtr deep blow GL with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15 cm thick packed layer of vharcoal dust and common salt filled in alternate layers and electrode connections by using Galvanised earth lead wire 4 mm connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 40 mm dia GI pipe light grade for protection of GL earth strip and 20 mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) type B1 chamber, MS funnel, wire mesh, 50 mm thick RCC 1:2:4 type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 Mtr, Provision of charcoal and slat complete all as shown in electrical plate No 3 of schedule SSR Part-I.
Taking down UNSV serviceable GI pipe of any size complete
M & L for cutting existing steel tubing upto 50mm dia and inserting suitable GI fittings etc for alterations/addition the branch connection complete.
Excacvation in trenches not exc 1.5 mtr wide and n exc 1.5 mtr in depth and getting out in soft/loose for laying pipes complete all as specified.
Returning, filling in including spreading, levelling, watering and well ramming in layers n exc 25 cm in soft/loose soil complete all as specified.
Removing excavated material n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point
Supply & laying GI pipe medium grade including fittings 25mm dia complete all as specified.
Supply & laying GI pipe medium grade including fittings 20mm dia complete all as specified.
Supply & laying GI pipe medium grade including fittings 20mm dia complete all as specified.
Supply & fix in replacement gun metal gate valve with Iron wheel head, screwed both ends for pipe 25 mm dia complete.
Supply & fix gun in replacement metal gate valve with Iron wheel head, screwed both ends for pipe 20 mm dia complete.
Supply and fix stop bib tap cast copper alloy high pressure with crutch handle fanc type , screwed both ends for iron pipe for union and fixed to 15 mm dia bore GE medium grade pipe complete all as specified and as directed.
MARUTI BUILDERS
M/S Gupta Builders
Shikhar ji Enterprises
Builders Harpal
S R BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .