| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.1 CrAccepted-AOC | ₹8.1 Cr | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹8.6 Cr+₹47.3 L (5.85%)Rejected-Finance 17 1624A MUMDAMVELI KOCHI 682 507 | ERNAKULAM | KERALA | 682507 | ₹8.6 Cr+₹47.3 L (5.85%) | L2 | Rejected-Finance Being higher bidder |
| 3 | L3₹8.6 Cr+₹48.8 L (6.03%)Rejected-Finance | ₹8.6 Cr+₹48.8 L (6.03%) | L3 | Rejected-Finance Being higher bidder |
| 4 | L4₹8.9 Cr+₹78.3 L (9.68%)Rejected-Finance | ₹8.9 Cr+₹78.3 L (9.68%) | L4 | Rejected-Finance Being higher bidder |
| 5 | L5₹9.0 Cr+₹91.6 L (11.3%)Rejected-Finance | ₹9.0 Cr+₹91.6 L (11.3%) | L5 | Rejected-Finance Being higher bidder |
Tender Value
₹8.3 Cr
EMD Value
₹7.4 L
Closing Date
19 Sept 2020, 6:00 pmClosed
HQ CEJZ JODHPUR
HQ CEJZ JODHPUR
PROVISION OF SURGICAL AND MEDICAL WARD AT MH AHMEDABAD (JOB NO. 005/AMWP/12C/2017-18)
2020_MES_357270_1
800486/AMD/E8
Open Tender
Civil Works
Lump-sum
1390 days
AHMEDABAD
AS PER NOT
10 documents required · 10 mandatory
₹3,000
Yes
GE AHMEDABAD
₹7.4 L
Yes
HQ CEJZ JODHPUR
18 Nov 2020
1 Jul 2020
21 Sept 2020
1 Jul 2020
19 Sept 2020
12 Sept 2020
10 Jul 2020
Amount
Lump sum price worked out by the contractor for "BUILDING WORKS" as listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 27(R)(R)
Lump sum price worked out by the contractor for "SITE CLEARANCE, EXCAVATION & EARTHWORK" as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 29(R)
Lump sum price worked out by the contractor for "INTERNAL WATER SUPPLY " as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 30(R)
Lump sum price worked out by the contractor for "INTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 32(R)
Lump sum price worked out by the contractor for "ROAD & PATH" as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 35(R)
Lump sum price worked out by the contractor for "SEWAGE DISPOSAL" as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 37(R)
Lump sum price worked out by the contractor for "AIR CONDITIONING" as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES B/F from Sl page No. 38(R)
Lump sum price worked out by the contractor for "FIRE ALARM & DETECTIONS SYSTEM" as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 39(R)
Lump sum price worked out by the contractor for "EXTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 40
Lump sum price worked out by the contractor for "EXTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 42(R)
Lump sum price worked out by the contractor for "LIGHTENING PROTECTION" as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 43
Lump sum price worked out by the contractor for "DEMOLITION / DISMENTLING" as listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 44(R)
Lump sum price worked out by the contractor for "RAIN WATER HARVESTING" as listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 44(A)
Sch 'A' PART-XIV (MISCELLANEOUS ITEMS) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under respective schedule.
INTERNAL WATER SUPPLY S&F of continental 2 way bore bib taps (wall mount installation type) of brass, knob and flange plate chrome finish complete all as specified and directed. Make - Jaquar Model No Con-041KN or technocommercial equivalent makes as per Appx 'C'.
S&F Angular stop cock quarter turn (wall mount) with 1/2 inch hole diameter made of brass complete all as specified and directed. Make - Jaquar Model No ARI-CHR-39053 or technocommercial equivalent makes as per Appx 'C'.
S&F for Stainless steel concealed stop cock, Regular body with adjustable wall flange, size 1/2inch dia complete all as specified and directed. Make - Jaquar Model No CON-CHR-083KN or technocommercial equivalent makes as per Appx 'C'.
S& F overhead shower round shape single flow (ABS body crome plated with gray face plate) with rubit cleaning system complete all as specified and directed. Make - Jaquar Model No OHS-18736 or technocommercial equivalent makes as per Appx 'C'.
S&F Health faucet complete kit (PVC hoze, Hand set, ABS body & bracket) 1.00 Meter long complete all as specified and directed. Make - Jaquar Model No ALD-CHR- 583 or technocommercial equivalent makes as per Appx 'C'.
S&F PVC connections 1m long of size 1/2 inch with end fiiting brass (drinking water pipe) jaquar brand or techno commecial equivalent makes as per Appx 'C' complete all as specified and directed.
S&F sensotronic sensor flushing valve for urinal with complete kit all as specified and directed. Make - Jaquar model-SNR-CHR-51097 or technocommercial equivalent makes as per Appx 'C'.
S&F Brass LONG NECK BIB TAP, handle controlled, wall mount installation type complete all as specified and directed. Make - Jaquar Model No. CON -021KN or technocommercial equivalent makes as per Appx 'C'.
S&F cast copper alloy chromium plated wall mixer with provision for overhead shower with 115 mm long bend pipe on upper side connecting legs & wall flanges complete all as specified and directed. Make - Jaquar model-CON-273-KNUPR or technocommercial equivalent makes as per Appx 'C'.
INTERNAL ELECTRIFICATION S&F wireless nurse call bell system with 10 call panel complete all as specified and directed.
S&F telephone jak with Modular metal flushed including flushed Box cover plate Box for 2 Way module complete all as specified and directed.
S&F TV SOCKET with Modular metal flushed including flushed Box cover plate Box for 2 Way module complete all as specified and directed.
S&F Hand dryer 220 Volts AC material ABS plastic automatic sensing time 30 Sec complete all as specified and directed. Make - Jet or technocommercial equivalent makes as per Appx 'C'.
Supply, installation and testing of evaporative type Air cooler (Desert Cooler) Plastic body, 230 Volts, single phase, having capacity of 4000 cum/hr (450 mm Sweep) Water storage capacity not less than 52 Ltrs, 15 mm dia floot valve and suitable PVC connectors, mosquito proofing net for all sides including fixing arrangements with suitable size of MS angle iron stand with wheel arrangments complete all as specified and directed. Make: Symphony, Bajaj, Crompton, Havells
S&F Geyser capacity 25 Litre, 230 Volts, 50 Hz rated wattage 2 KW 5 star rating complete all as specified and directed.
S&F Flame proof exhaust fan diameter 16 inch speed 1400 RPM complete all as specified and directed.
S&F 12 Watt 220 Volts reading lamp complete all as specified and directed.
S&F LED light fittings decorative 18 Watt Recessed mounting type extruded metal/aluminium body, and electronic LED driver, connector block ect. with all accessories internal prewired & including connecting up with 2 core flexible cppper conductor cable with suitable size and mounting clamps etc complete all as specified and directed.
S&F LED light fittings decorative 18 Watt surface mounting type extruded metal/aluminium body, and electronic LED driver, connector block ect. with all accessories internal prewired & including connecting up with 2 core flexible cppper conductor cable with suitable size and mounting clamps etc complete all as specified and directed.
S&F LED 6 Watt night lamp extruded metal/aluminium body, and electronic LED driver, connector block ect. with all accessories internal prewired & including connecting up with 2 core flexible cppper conductor cable with suitable size and mounting clamps etc complete all as specified and directed.
S&F LED 5Watt wall mounted bulb extruded metal/aluminium body, and electronic LED driver, connector block ect. with all accessories internal prewired & including connecting up with 2 core flexible cppper conductor cable with suitable size and mounting clamps etc complete all as specified and directed.
S & F ceiling mounted Porch light 5/7 watt LED extruded metal/aluminium body, and electronic LED driver, connector block ect. with all accessories internal prewired & including connecting up with 2 core flexible cppper conductor cable with suitable size and mounting clamps etc complete all as specified and directed.
S&F LED tube light fittings decorative ultra slim linear fixture with extrudedalluminium heat sink envioromentel friendly Energy efficient ready to use pack ,1x14Watt ,4 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block ect.with all assoceries intenal prewired & including coneecting up with 2 core flexible copper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nos etc complete all as specified and directed.
S&F LED tube light fittings decorative ultra slim linear fixture with extrudedalluminium heat sink envioromentel friendly Energy efficient ready to use pack ,1x20 Watt ,4 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block ect.with all assoceries intenal prewired & including coneecting up with 2 core flexible copper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nos etc complete all as specified and directed.
S&F LED tube light fittings decorative ultra slim linear fixture with extrudedalluminium heat sink envioromentel friendly Energy efficient ready to use pack ,5 Watt ( for mirror light), 2 feet, surface mounting type extruded pvc, snap on installers and domestic electronic Driver, connector block with all assoceries internal prewired & including connecting up with 2 core flexible copper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nos etc complete all as specified and directed.
S&F LED Security/Street light fittings 60 Watt wall mounting type extruded metal/aluminium body, and electronic LED driver with all accessories internal prewired & including connecting up with 3 core flexible copper conductor cable with suitable size etc complete all as specified and as directed
Fabricate, supply & fix GI pipe bracket light grade 25mm dia- 0.9m long & 2 set of clamps made out of 30x5mm MS flat & fixed with anchor bolt suitable for 60 Watt security light fitting complete all as specified and as directed
S&F MCCB/MCB Distribution board, concealed flush to wall for mounting MCCBs and MCBs , factory made, fabricated out of CRCA sheet not less than 1.20mm thick fitted with DIN channel , neutral link ,DBs shall be semi glossy finished with epoxy polester based powder paint process to ensure smooth finish and protection against corrosion atmosphere, the DBs shall be double door type with hinged door with locking arrangement. the DBs shall be of same make as MCCBs, DB shall also be provided with lable marking indicating the incoming and outgoing circuits on all ways specified . the DBs shall be IP 43 protection class for the following:
MCCB DB vertical suitable for 200 Amp TPN 4 way 415 V
MCB DB suitable for 200 Amp SPN 8 way
S&F of MCBs/MCCBs, of following capacity, IS-8828 marked of the undermentioned type and rating and fixing in DBs (DBs catered separately in this Schedule)
SP MCB 6 Amp 10 KA rupturing capacity 240 Volts C series
SP MCB 10 Amp 10 KA rupturing capacity 240 Volts C series
SP MCB 16 Amp 10 KA rupturing capacity 240 Volts C series
SPN MCB 20 Amp 10 KA rupturing capacity 240 Volts C series
TPN MCCB 125 Amp 16 KA rupturing capacity 415 Volts C series
M&L for Sub main wiring with Two runs of 2.50 Sqmm size main cable and one run of 2.50 Sqmm size earth continuty conductor of single core PVC insulated but unsheathed FRLSH cable multi standed copper conductors, 1100 volts grade, IS-694 marked all drawn through and including suitable size rigid steel conduit pipe medium grade 25 mm dia ISI marked & fittings/ accessories all fixed to the surface of wall/ceiling complete all as specefied & directed.
M&L for Sub main wiring with Two runs of 4.0 Sqmm size main cable and one run of 4.0 Sqmm size earth continuty conductor of single core PVC insulated but unsheathed FRLSH cable multi standed copper conductors, 1100 volts grade, IS-694 marked all drawn through and including suitable size rigid steel conduit pipe medium grade 25 mm dia ISI marked & fittings/ accessories all fixed to the surface of wall/ceiling complete all as specefied & directed.
M&L for Sub main wiring with Two runs of 6.0 Sqmm size main cable and one run of 6.0 Sqmm size earth continuty conductor of single core PVC insulated but unsheathed FRLSH cable multi standed copper conductors, 1100 volts grade, IS-694 marked all drawn through and including suitable size rigid steel conduit pipe medium grade 25 mm dia ISI marked & fittings/ accessories all fixed to the surface of wall/ceiling complete all as specefied & directed.
M&L for Sub main wiring with Two runs of 10 Sqmm size main cable and one run of 10 Sqmm size earth continuty conductor of single core PVC insulated but unsheathed FRLSH cable multi standed copper conductors, 1100 volts grade, IS-694 marked all drawn through and including suitable size rigid steel conduit pipe medium grade 25 mm dia ISI marked & fittings/ accessories all fixed to the surface of wall/ceiling complete all as specefied & directed.
M&L for Sub main wiring with Two runs of 16 Sqmm size main cable and one run of 16 Sqmm size earth continuty conductor of single core PVC insulated but unsheathed FRLSH cable multi standed copper conductors, 1100 volts grade, IS-694 marked all drawn through and including suitable size rigid steel conduit pipe medium grade 25 mm dia ISI marked & fittings/ accessories all fixed to the surface of wall/ceiling complete all as specefied & directed.
Note for item No 44.00 to 48.00: The above mentioned specefied runs of single core cables and specefied runs of earth continuity conductors and the relevant conduit with accessories shall be measured as one runs length. The small extra lengths required for loops etc for connection in DBs shall deemed to be included in quoted rate and only the cable covered in conduit shall be measured.
S&F Exhaust fan 5 star rated heavy duty of size 230 mm sweep metal body complete with louvers connecting up including provision of three core flexible copper wire of size 23/0.0076 from ceiling rose to exhaust fan complete all as specefied & directed.
S&F Energy efficient BEE 5 star rated ceiling fan, 1200 mm sweep and connecting up including provision of three core flexible copper wire of size 23/0.0076 from ceiling rose to ceiling fan complete all as specefied & directed.
M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 metre deep below ground level) with the top edge of earth plate at a depth not less than 1.5 metre below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI earth wire 4 mm dia bolted (with GI nuts, bolts & check nuts) and rivetted to earth (Plate) electrode at one end and connected to main switch board / DB at the other, earth wire protected by and including GI pipe 15 mm dia (light grade) from top of electrode to main switch board and also including test point made out of 40 mm x 6 mm aluminium flat watering pipe GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode complete with earth pit in PCC (1:3:6) type C1, 50 mm thick pre cast RCC cover slab (1:2:4) type B1 set in CM (1:4), reinforced with 8 mm dia TMT bars @ 15 cm c/c and suitable handle of 10 mm dia MS round bars including earth work in excavation in any type of soil, disposal of soil not exc. 50 meter complete and testing on completion including, funnel, wire mesh all as shown in electrical plate No-3 of MES schedule, part-I complete all as specified and directed. NOTE : (i) Item includes the cost of 7.5 m GI pipe 15 mm bore light grade for protection of GI wire. (ii) Item includes the cost of 7.5 m of GI wire. (iii) PCC pit shall be provided at least 0.5 mtr away from earth pit and not on the earth pit itself and the extra cost of additional length of watering pipe bends, elbow etc shall be deemed included in the unit rate quoted.
ROAD, PATH & CULVERT M&L for 150 mm thick (compacted thickness) READY MIX WET MIX MACADAM using materials of 30 CBR, in two layers each of 75 mm thick (each layer to be rolled and consolidated separately) conforming to the grading given in table 400-13 and physical requirement given in table 400-12 spread with mechanical means as specified, hollows made up to form true surface, spread, surface binding with and including screening and moorum, watered, consolidated and rolled with vibratory roller 8 to 12 tonne as per clause 406.3.5 of MORT & H to required gradient and camber complete all as specified and as directed.
M&L for marking 2.00 mm thick centre line dashes, arrows,brackets & similar work on road surface as par IRC pattern with thermoplastic Paint of approved make & mix with 8% mica of white / yellow colour as approved of temrature 160 degree C & applying with special applicator machine complete and making trafic diversion arrangements complete all as specified & directed.
EXTERNAL WATER SUPPLY M&L for Constructing masonry chamber 60cm x 60cm x 60cm inside with Brick work in subclass B in cement mortar 1:4 for sluice valve with necessary excavation, foundation Type D2 1:4:8 concrete (40mm graded aggregate) and inside plastering with cement mortar 1:4, 12mm thick finished with a floating coat of neat cement complete as per standarad design including MS cover of 3 mm thick sheet and angle iron frame 40x40x6mm size with locking arrangement complete all as specified and directed.
M&L cutting of existing CI/DI 150 mm bore pipe line and inserting CI tee / Bend / reducers / Tail pieses and necessary CI fitting including jointing and jointing material necessary excavation / earth work at any type of soil complete all as specified and directed.
S&F gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe of 80 mm dia complete all as specified and directed.
EXTERNAL ELECTRIFICATION Supply, install, testing and commisioning of DISTRIBUTION transformer mounted on massonry platform size 2000x2000x1200mm stepdown, 11KV 0.433KV, Three Phase complying with IS:1180 (Part-1) 2014 with latest ammendments, OUTDOOR type copper wound suitable for 50 Hz system of capacity 250 KVA, Level-3 oil immersed naturally cooled delta connected on HT side and Star connected on LT side, Vector Group Dyn11, provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5% in step of 2.5 %. The transformers should be supplied with first filling of oil confirming to IS 335 .The transformer should have one LT cable end box with neutral brought out complete all as specified & directed. Note:- The quotaed rate shall deemed to be include the cost of platform & foundation as recommended by manufacturer.
M&L for earthing complete with galvanized steel earth electrode 60 cm x 60 cm x 6 mm buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with the top edge not less than 1.5 mtr below ground level connected to galvanized iron strip 32x6 mm by means of bolts, nuts, chock nuts and washers and other end connected to earthing test point including test point made out of 40x6 mm aluminium flate, funnel, watering pipe of 20 mm bore (Medium grade) GI pipe wire mesh, charcoal or coke and common salt in alternate layers all around the earth electrode compacted thickness 15 cm, earthing pit in PCC (1:3:6) type C1, 50 mm thick pre cast RCC cover slab (1:2:4) type B1 set in CM (1:4), reinforced with 8 mm dia TMT bars @ 15 cm c/c and suitable handle of 10 mm dia MS round bars including earth work in excavation in any type of soil, disposal of soil not exc. 50 meter complete and testing on completion all as shown in electrical plate No-3 of MES schedule, part-I complete all as specified and directed.
NOTE FOR ITEM NO. 59.00:- (i) Item includes the cost of 7.5 m GI pipe 40 mm bore light grade for protection of GI strip. (ii) Item includes the cost of 7.5 m of GI strip. (iii) PCC pit shall be provided at least 0.5 mtr away from earth pit and not on the earth pit itself and the extra cost of additional length of watering pipe bends, elbow etc shall be deemed included in the unit rate quoted.
Supply, install, testing and commissioning of HT 11 KV, 3 Phase, 50 Hz, totally enclosed metal clad SF6 switchgear having rupturing capacity upto 630A, RMU, rated voltage 12 KV, rated power frequency withstand voltage - 28 KV, rated lightning impluse withstand voltage-75 KV, rated current for ring main feeder-400/630A, rated short time current-21KA/3 Sec, rated short making current-50KA Cu Busbar, Motorised operated, outdoor, non extensible, one LBS and one VCB in single unit (1xLBS + 1xVCB) without metering, ambient temperature-40 degree C with IP 54 including necesary foundation as directed by Engineer in Charge
S&F Area lighting LED 120 Watts, energy saving environmental friendly, long life exclusive innovatiive die cast aluminium IP 66 flood light with high power LED as light source suitable for high lighting architectural features or retail spaces complete all as specified and directed (For high mast)
S&F PVC junction box IP 65 Protection of size 300 x 200x 125mm complete with 1 Nos of MCB 6Amps & 4 way industrial connector including Clamp made out of MS flat 30X5 mm, connection from junction box to street light fitting with three single core PVC insulated , PVC sheathed wire 2.5 Sqmm copper & PVC coduit 20 mm dia complete all as specified and directed.
Supplying, erecting, testing and commissioning Raising & Lowering type 16 metre height High mast light hot rolled M S Plate, suitable for wind speed 50 Mtr/Sec compliance with IS 875 (Part -III) standards. The section are welded longitudinally in compliance to BSEN ISO 1011/IS10178. seam weld per section but without circumferential weld including accessories viz head frame, 2-point suspension system with stainless steel wire rope 6 mm dia , double drum winch, lantern carriage arrangement suitable for 06 luminaires symetrically, lightning finial, LED aviation obstruction light, lightning arrester spike, foundation bolts, nuts, anchor plates, templates, trailing cable & intergral power tool for raising and lowering operation of high mast with and including as foundation details drg given by OEM with following main technical specifications:-
HIGH MAST STURCTURE DETAILS Height of mast - 16 m No of sections - Two Material construction - Hot rolled MS Plate as per BSEN10 025 / IS 5986 Gr Fe 510. Base diameter and top diameter - 410 mm & 150 mm Thickness 3/3mm, PCD-490 mm (8 hole). Plate thickness & section length - Top - 3 mm x 5420 mm, Bottom - 3 mm x 10980 mm. Cross section of Mast - 20 side polygon Diameter of base plate - 570 mm Thickness of base plate - 25 mm Pitch Circle diameter of foundation bolt - 490 mm Lightning protection finial - GI single spike Maximum wind speed - 180 Km/Hr as per IS : 875 (Part - III) Number of foundation bolts - 8 nos Size - M30x8 Nos, 850mm long Anchore & template LUMINAIRES CARRIAGE Material of construction - 50 NB ERW Class 'B' - MS Pipe Diameter of carriage ring - 535 mm Construction - 8 Arms, welded, 2 sections Load carrying capacity - 6 Luminaire (approx 750 Kg)
WINCH / POWER TOOL Winch capacity - Double drum, Approx 750 Kg Gear ratio - 53:1 Method of operation - Mannual / Motorized Motor Capacity - 1 HP No of speecd - 6 pole, single speed STAINLESS STEEL WIRE ROPE Stainless steel wire rope - 2 for winch Grade / Construction - AISI 316, 7/19 consturction Number of ropes - Two continuous Dia - 6mm Braking load capacity - 2350 kg x 2
MAST HEAD ASSEMBLY Construction - Non corrosive material hot dip galvanised. Pulley : self lubricating bearing with stainless steel spindles. FEEDER PILLAR Powder coated CRCA steel sheet feeder pillar housing 2.0 mm thick (minimum) with 32 Amp four pole MCB incomer, timer 16 Amp, 230 volts single dial time switch and 25 Amp contactor suitable for automatic switching ON and OFF of the luminaires, 9 Amp two contactors and raise lower push buttons for motor operation, incoming terminals of 35 sqmm and outgoing terminals of 16 sqmm for power cable and 2.5 sqmm for motor mounted on suitable foundation. FOUNDATION Construction of suitable shallow foundation with M20 grade concrete for high mast considering the safe soil bearing capacity at site as 10T/sqm at 2 m depth. TRAILING CABLE 5 core 2.5 sqmm EPR coated, ECP sheathed round copper conductor as required. Note : Lumanaries will be measued and paid separately.
S&F PVC insulated PVC sheathed 1100 volts grade multistranded copper conductor armoured cable of 1.5 sqmm 3 core drawn and through including PVC conduit complete all as specified and directed.
S&F time switch 230V single phase of 20 AMP rating wall mounting 110x85x60mm size, 30A heavy duty relay at 230V AC for outputs, real clock time RTC based, Enclosure- ABS Plastic heavy duty, inbuilt battery backup 1000hrs complete all as specified and directed.
Supply, Installation, test and Commissioning CPRI approved factory fabricated, out door type, double doorLT Pannel Board with powder coating made out of 3.00 mm thick CRCA Sheet with projected globe roof for rain water protection dust and Vermin Proof, Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation including complete all as specified and comprising of the following :– (Main LT panel)
Busbar:- (i) Electrolytic copper bus bar 800 amps,supported on non hygroscopic fibres and brass screw for mounting -04Nos (a) Incomer (i) MCCB 4 pole adjustable thermal magnetic release,415 volts 630 Amps 36KA-01NOS (b) Outgoing (i) MCCB 4 pole adjustable thermal magnetic release,415 volts, 400Amp, 36KA-01 Nos(for AC plant) (ii) MCCB 4 pole adjustable thermal magnetic release,415 volts, 250Amp, 36KA-01 Nos(for sub panel GF) (iii) MCCB 4 pole adjustable thermal magnetic release, 415 volts 250Amp,36KA-01Nos(for sub panel FF) (iv) MCCB TPN adjustable thermal magnetic release, 415 volts 32Amp,16KA-02Nos(for High mast light/security light) (v) Digital Ammeter 3 phase including CT ratio 300/5(three Nos Of CT) . (vi) Digital voltmeter 3 phase 0-500Volts (vii) Indicting lamp LED type ,230Volt for RYB including all necessary arrangement-01set (viii) On load change over 250Amp, 415Volt complete-1No
Ditto all as item No- 65.00 here in before but consisting of followings:- (SUB PANEL GF)
Ditto all as item No- 65.00 here in before but consisting of followings:- (SUB PANEL FF)
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, indoor type, APFC capacitor bank Panel Board of size as recommended by manufactrer 100 KVAR with 10 stages (4x12.5 + 4x10 + 2x5) WITH MD-XL CAPACITOR IS:13585-1994 AND MCCB AS INCOMER Automatic Power Factor Correction panel , made out of 2 mm thick CRCA Sheet Dust and Vermin Proof, single door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System,The enclosure shall be pre-treated as per 11 tanks process and finished with powder coating of shade RAL 7032. , including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers etc.The panel will be supplied with control contactor, MCB for control circuit ,timer etc as required , and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Testing after Installation complete all as specified and directed. The panel shall be factory fabricated comprosing of following:-
12.5 KVAR Capacitor feeder comprising of:- ( 4 Nos. ) 40A, BUSSMANN FUSE- 6 NOS Thyristor switching module 12.5kVAR, 440V,TSM,LTTSM - 2 NOS 7% Detuned Aluminium Reactor 12.5KVAr 440V LTAL,CAT NO-0712B2- 2 NOS Ultra heavy duty capacior LTXL , BOX type oil Filled Capacitor bank 12.5 kVAr, suitable for 480V Push Button ON/OFF -4nos Indicating lamps 3 NOS Auxiliary Contactor {2NO+2NC} 24V DC Coil Voltage MXO- 2 40A DP MCB , C CURVE 2 NOS 10 KVAR Capacitor feeder comprising of:- ( 4 Nos. ) 32A, BUSSMANN FUSE- 6 NOS Thyristor switching module 25KVAR, 440V,TSM,LTTSM - 2 NOS 7% Detuned Aluminium Reactor 10KVAR 440V LTAL,CAT NO-0712B2- 2 NOS Ultra heavy duty capacior LTXL , BOX type oil Filled Capacitor bank 10 kVAr, suitable for 480V Push Button ON/OFF -2nos Indicating lamps 3 NOS Auxiliary Contactor {2NO+2NC} 24V DC Coil Voltage MXO- 1 32A DP MCB , C CURVE 1 NOS
DG SET (a) Supplying, installing, testing and commissioning, factory assembled silent Diesel Engine driven generator set, fully wired alternator AC to give an out put of 250 KVA continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hz ± 1% supply, 1500RPM, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank capacity 460 liter (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturer's instructions, vibration damper pads, control panel & other accessories etc and comprising of following:-
(b) Diesel Engine:- Liquid cooled turbo charged with after cooler to deliver suitable BHP at 1500RPM under NTP conditions of BS 5514 and conforming to IS 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries of adequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete. (a) Radiator with blower fan or heat exchanger with guard. (b) Pipe coupling for engine cooling system piping. (c ) Corrosion inhibitor coolant (d) Paper element filters (e) Fuel filter (f) Lube oil filter (g) By pass (h) Fly wheel housing and fly wheel to suit alternator. (i) Engine bearing mechanism in fly wheel housing. (j) Shut off coil with safeties for LLOP/HWT/over speed. (k) Dry type air cleaners and vacuum indicators. (l) Residential silencers. (m) Stainless steel exhaust flexible bellows. (n) Motor driven priming pump. (o) Battery charging alternator.
(p) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturer's recommendations to sustain back pressure with rain cap. (q) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet 30 gauge for the entire length of exhaust pipe. (r) First fill of oil, coolant and diesel during commissioning and 12 hours testing. (s) Interconnecting copper cabling of adequate capacity batteries control. (t) Fuel pipe class STIC 1" /1.5" /2" dia - 01 lot (u) Self starter 12 volts DC. (v) Electric operated electronic governor. (w) Fuel injection pump. (x) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturer's design alonwith AVM pads. (y) Battery:-24 volts(02x12vBattery) DC, 180AH, maintenance free battery conforming to IS:14257 with leads & terminals (Make- Excide/Amron). (z) Fuel tank: 10 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed.
(c) Electronic instrument panel, complete with all accessories as per manufacturer's specifications displaying the following:- (i) 24V Battery. (ii) Water temperature. (iii) lubricating oil pressure. (iv) Engine speed -1500Rpm (v) Engine hours (vi) Frequency. (vii) Voltage. (viii) Safety control (Trip and indication). (ix) High water temperature (x) Low lube oil temperature (xi) Overspeed stop
(d) Alternator:- Suitable rated 250 KVA, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushles, screen protected, drip proof , insulation class-H, IP -23, voltage regulation grade - VG 3 self ventilated and conforming to BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before, conformig to IS: 13364(part-1) (e) Acoustic Enclosure:- M & L for acoustic enclosure for the above 250 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board and size 3490 x 1340 x 1885mm and manufacturer's specification and comprising of following from authorised GOEMs of Gen Set manufacturer's specified :- (i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum). (ii) Outer body : 1.6mm thick CRCA (iii) Door : 1.6mm thick CRCA (iv) Base frame : ISMC 300 (v) Inside illumination : 1 No.- 1 x 18 watt FTL fitting. (f) AMF Control panel:- Factory fabricated cubicle type, free standing, floor mounted, indoor type, IP-52, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick CRCA sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following:- (g) AMF control circuit with 4 pole MCCB 400 Amps - 2 nos, with ultimate breaking capacity Icu-36 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity Ics=Icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc.
(h) Digital load manager:- Three phase 4 wire indicating V,I,PF, KVA, KW, F of Enercon make with serial communication port model No.EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No. (iii) Indication lamp R, Y, B with 3 Nos. of 2A HRC fuses-10 sets. (iv) Bottom gland plate for incoming and outgoing cables. (v) Circuit diagram plate. (j) Civil works:- All civil works related to foundation, installation of panel and equipment & depth of foundation shall be minimum 300mm with ant vibration pads, or as recommended by manufacturers. Cable from DG set to AMF panel, AMF panel to main panel will be measured under relevant schedule. Note:-The fuel for final testing of 12 hours shall be supplied by the contractor and cost deemed to be included in the above offer. All other necessary equipments like resistance load strip heater of suitable capacity/rating and any other items required for final testing shall be provided by the contractor without any extra cost to department.
COOLING APPLIANCES S&F water cooler 5 star rating electric driven (single phase) having approx storage capacity of 120 litre and nominal cooling capacity of 60 liters per hour, (grade AISI 304), stainless steel body Eco friendly (Non CFC Refrigerant) complete all as specified & directed.
Supply, installation and testing of refrigerator not less than 320 Litre capacity, 230 V, 50 HZ, BEE 5 star rating, frost free, double door with humidity control and deoderizer, toughned glass shelves, stabilizer free operation, inverter technology compressor, rust resistance body, dual thermostart for refrigerator & freezer, with cool pack, complete all as specified & directed.
S&F voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA complete all as specified and as directed.
Supply and install water purifier suitable for mounting on wall and for water cooler, refrigerator, on RO+UV+UF+TDS control technology with water purifier capacity of 15 liter/hour with input voltage 230VAC, 50HZ complete all as specified and as directed. Make:- Eureka Forbs (Aquaguard) or techno commercial equivalent as per Appx 'C'
MEDICAL GAS SUPPLY SYSTEM
Supply, installation, testing and colour copper pipe outer dia 12 mm, 0.80mm thick certified EN 1057 Standards all as specified Make - Lloyds, ASTMB75, MAXFLOW
Supply, installation, testing and colour copper pipe outer dia 15 mm, 1mm thick certified EN 1057 Standards all as specified Make - Lloyds, ASTMB75, MAXFLOW
Supply, installation, testing and colour copper pipe outer dia 18 mm, 1mm thick certified EN 1057 Standards all as specified Make - Lloyds, ASTMB75, MAXFLOW
Supply, installation, testing and colour copper pipe outer dia 22 mm, 1mm thick certified EN 1057 Standards all as specified Make - Lloyds, ASTMB75, MAXFLOW
Supply, installation, testing and colour copper pipe outer dia 28 mm, 1mm thick certified EN 1057 Standards all as specified Make - Lloyds, ASTMB75, MAXFLOW
Supply, installation, testing and colour copper pipe outer dia 35 mm, 1.2mm thick certified EN 1057 Standards all as specified Make - Lloyds, ASTMB75, MAXFLOW
Supply, installation, testing and colour copper pipe outer dia 42 mm, 1.20mm thick certified EN 1057 Standards all as specified Make - Lloyds, ASTMB75, MAXFLOW
Supply, installation, testing and colour copper pipe outer dia 54 mm, 1.2mm thick certified EN 1057 Standards all as specified Make - Lloyds, ASTMB75, MAXFLOW
S&F O2, Air bar, Vaccum outlet point online service front loading parking way facility all future OR Double Locking Outlet point (CE marked) complete all as specified and directed. Brand - Ambica Surgicare/ABS System/Silbermann Brand : Ambica Surgicare
S&F isolation valve of suitable size complete all as specified and directed. Brand : Hospitonic/Amico/Medflo
S&F CENTRAL OXYGEN (O2) Manifold system :12+12 Bulk cylinder Manifold for oxygen complete with middle frame, bottom frame, NRV and Tail piece complete all as specified and directed. The manifold system shall conform to IS 12827 Make : Panki Oxygen/MAP/OXEECO
S&F 1x4 Cylinder Emergency Oxygen system supply through regulator having Non Halogenateed polymer in high presssure side complete all as specified and directed. The manifold system should conform to IS 12827 Make-OXY99/MAP/OXEECO
S&F Automatic Control Panel with Filter For Oxygen input power 240VAC 50 Hz complete all as specified and directed. Brand - MAP/MEDLINE/OXYTECH ENGINEERS
S&F Air compressed system of 1000 lpm Duplex air plant system with a working pressure of 10 bar, 400V 3-phase, 50 Hz, scroll type compressor 10 HP-2 Nos, duty compressor-1 No & stand by -1 No, sound power 62 db, dryer-02 Nos, each compressor have control panel digital type and capable monitoring and shows hours run, technical alarms, fault alarms, service menu, low and high pressure set, temperature of the system etc, automatic drain valve and maual drain valve for each compressor, should have silencer, emergency stop button on each compressor and also should have non returning valve for each compressor all as specified Make-Compet/Model MEDAIR-1000-10GD/ANEST IWATA/COMPAIR (a) Air filter/dryer system - Air filter/dryer system should be ISO 13485:2003 certified for UL certified. (b) The prefilters shall be in acordance HTM 02-01 standards with an efficiency of 95%. (c) Oil filters shall be of the coalescing absorption type, removing 99% of oil and water particles between 5 and 40 microns (d) Filtering should ensure complete oil removal so that only oil free air enter the heatless regenerative desiccant dryer. (e) Should also have dust/activated carbon filters, hopcolite filter and bacterial filter with autocclavable element. (f) There should be visual indication to replace the cartridge. (g) Contaminants in the delivered air downstream of the bacterial filters shall be maintained at levels below those shown in the following table :- Containment Threshold H2O 67 ppm v/v Dry particulates Free from visible particulates in a 75-litre sample Oil (droplet or mist) 0.1 mg/m3
S&F Air Receiver of 2000 ltrs inlet pressure 10 Kg/cm 2 complete all as specified and directed. Make-Roteck/Model : RAR 2.0/ATMOS POWER/VENUS
S&F Central vaccum system for medical vaccum pipeline system should be design to maintain a vaccum of at least 300 mm Hg (40kPa) at each terminal unit complete all as specified and directed. (a) The pump installation shall be duplex sytem consisting of two HP dry type vaccum pump each of which shall be capable of independently producing designed systems flow rate. (b) Each pump should have capacity of minimum 130 cfm. Pump should be capable of providing a vaccum of not less than 650mm Hg (87kPa) (c) Each vaccum pump shall have its own exhaust line and each shall be fitted with suitable drain valves and transparent jars at the lowest points. (d) The outlets shall be suitably protected to prevent the ingress of rain, and wind pressure. A weather proof notice shall be provided at the discharge points which states : Medical Vaccum Discharge Pont - DO NOT OBSTRUCT. (e) The exhaust system shall be designed so that the back pressure does not exceed 80mm Hg (1.0 psi) at the design flow rate. (f) A length of flexible pipe work shall be included before the exhaust passes through a wall in order to isolate the building structure from pump vibration. (g) The vaccum system shall in all respect comply with the recommendation made in HTM 2022. HTM 02-01 Standard Make-Penumatics Engineer/OEM/ DRAIN VAC
S&F Bacteria filter station and secretion traps complete all as specified and directed. Make - Patel Gas Plants/PNEUMO CARE/OEM
S&F Vacccum receiver complete with 3000 ltrs complete all as specified and directed. Brand-VEER/Halward/AIRMECH
S&F Digital Alarm Panel with Fitting: Gas Line Digital Alarm panel should be provided in accordance with NFPA-99 complete all as specified and directed. (a) It should be suitably place as Master alarm/Area alarm/local alarm Brand-D-Tech Mediline/OEM/JK
S&F Area Valve Box with Valves, pressure Guage:3 Gas line valve Box complete all as specified and directed. (a) It should have diametric safety index system. (b) Colour specific hoses should not touch ground to prevent wear and tear. (c) Self sealing valve with smooth action (d) Push to inset and press to release valve Make-Meditech/OEM/JK
S&F BPC Flowmeter with Humidifier (oxygen line) capacity 200ml complete all as specified and directed. Brand : Meditech/OEM/JK
S&F Ward Vaccum Unit with jar regulator 1000/2000 ML complete all as specified and directed. Brand - Oxy Life/ANAESTHETICS PVT/ABS
S&F Conversion kit for O2 complete all as specified and directed. Brand - Medical bulk buy/GVS/MEDILINE ENGINEERS
S&F High Quality Refined Rubber LP Tubing complete all as specified and directed. Brand - KAN Power Rubber/BRIGHTEX/LATEX TUBING
Suppy and installation Aluminium coated Bed Head panel, iv pole and socket 5/15 amp complete all as specified and directed. Make-ABS System/Fabtrix/PIONEER INDUSTRIES
S&F IV Pole on each bed complete all as specified and directed. MAKE - Model - IB-3174/MEDIFA/MAXTEC
S&F Vaccum slider complete all as specified and directed. Brand-Serinity Healthcare/JK ENGINEERS/ROTAREX
S&F S.S basket for Monitor Led, Prob & BP Cuff complete all as specified and directed. Brand-Innovative/INMOCLINIC/JDMED
S&F Medical gas supply monitor complete all as specified and directed. Brand - PPS/HONEYWELL/OEM
S & F UPS 10 KVA for emergency power for life critical medical gas system equipment requiring electrical power for generation operation or alarm Make-Luminious Model LD 10000/SCHNEIDER/MICROTEX
S & F oxygen gas analyzer pressure less than 1.5 Kg/Cm Make - Patel Gas Plants/RAPIDOX/NUCON
S&F Area valve service unit HTM 2022/HTM 02-01 Standards to provide area isolation facility for use either in an emergency or for maintenance purpose configuration 3 gas system Make-MediTech/JK/OEM
AIR CONDITIONING Supply, installation, testing and commissioning of water cooled scroll compressor chilling machines 3 Nos Each of 39 TR (minimum) capacity, (2 Nos working and 1No Stand by) at below mentioned parameters with R-407C/R410 refrigerant multi-hermetically sealed scroll compressor driven by suitable KW squirrel cage induction motor, Star/Delta Starter with water cooled shell & tube condenser, insulated shell and tube flooded chiller should be designed for 12 deg C/7 deg C, flow switch at chiller and condenser outlet, suction and discharge refrigerant piping with heat exchanger globe, strainer, expansion valve, solenoid valve and antifreeze thermostat, first charge of refrigerant gas and oil, microprocessor based control panel all mounted on MS frame, vibration isolators and other accessories etc, including necessary foundation. The compressor motor shall be suitable for 400 V +/- 10%, 50 HZ +/- 1% 3 Phase AC supply.
The Chiller performance should be as per ECBC Publication for COP and IPLV. Typical Noise level (Sound Pressure) at 1 Meter distance from the Chiller and 1.5 Meter height 75 decibel (i) The chiller shall have an ARI certification label at no extra cost. Test certificate from ARI shall include capacity (TR/KW), Power (KW/TR), Pressure drop (ft of water), Integrated Part Load Value (IPLV) and shall be submitted. Note:- (i) AC plant has to maintain temp 21+/-2⁰C & RH 55+/-5%. All purchase Certificates and Test certificates shall be produced. Proof of Purchase from OEM be provided No Foreign Exchange or import licence will be provided by Department. Condenser: CDW in 90 Deg F CDW out 99.5 Deg F Fouling factor 0.001(hr-sq-ft-deg F)/Btu Chiller: CDW in 52 Deg F CDW out 43 Deg F Fouling factor 0.0005 (hr-sq-ft-deg F)/Btu (ii) Micro processor type panel board with compressor starter. Chiller should have been minimum COP 3.00 as per E-in-C policy and IPLV-6.43 (minimum) (The chiller software should have open protocol (BAC-net/Modbus) to connect with BMS system) (2 W + 1 SB)
Supply, installation, testing and commissioning of Monoblock horizontal pumping sets for chilled water circulation system. The pump shall be suitable for the given duty points - 3 Nos Each (Out of Three pumps, Two will be working and one will be standby). Make:- (Kirloskar or technocommercial equivalent makes as per Appx 'C') (i) Water Quantity - 96 USGPM (ii) Static Head - 20M (iii) Speed - 1450 RPM (iv) Impeller - Bronze (v) Shaft - Hig Tensile steel (vi) Pump/motor body - CI (vii) Seal - Mechanical (viii) Motor - Suitable HP TEFC (ix) Starter - Star-Delta (x) Base frame - Fabricated MS Note:- One set consist of Three Pumps
Supply, installation, testing and commissioning of Monoblock setof three pumps for condenser, Horizontal directly coupled pump of suitable discharge and head for condenser circulation system. The pumps shall be suitable for the given duty points operation - 3 Nos.(Out of Three pumps, Two will be working and one will be standby). All parameters as per Condenser pump as under. Make:- (Kirloskar or technocommercial equivalent makes as per Appx 'C') (i) Water Quantity - 120 US GPM (ii) Static Head - 25 M (iii) Speed - 1450 RPM (iv) Impeller - Bronze (v) Shaft - High Tensile steel (vi) Pump/motor body - CI (vii) Seal - Mechanical (viii) Motor - Suitable HP, Squirrel Cage SPDP (ix) Starter - Star-Delta (x) Base frame - Fabricated MS Note:- (i) Condenser and Primary chilled water pumps flow should match with chiller requirement. (ii) No price adjustment will be done due to variation in flow of pumps. (III) One set consist of Three Pumps
Supply, installation, testing and commissioning of Induced draft type cooling tower of 80 TR capacity with FRP water basin PVC fills, water distribution arrangement with self rotating sprinklers or fixed nozzles of PVC, statically and dynamically balanced axial flow fan direct driven, TEFC motor with suitable starter, suction screen, make-up and quick fill arrangement, overflow and drain connections, suitable GI inspection ladder, steel supporting structure, ant vibration mounting etc, complete as per manufacturer's design/specifications :- (i) Water Flow - 192 GPM (ii) Water in - 97.5 Deg F (approx) (iii) Water out - 83 Deg F (approx) (iv) Basin water Temp - 90 Deg F (approx)
Supply, laying, fixing, testing and commissioning of condenser water un insulated piping with MS ERW class ' C' pipe (Heavy duty (confirming to IS-1239-1958), complete with all accessories such as bends, elbows, flanges, nut-bolts, air purging valves, de-scaling valves. The piping shall be laid overhead in plant and underground outside the plant room as per site conditions of following sizes :-
100 mm dia
80 mm dia
Supply, install, testing and commissioning of following items :-
Balancing Valve 80 mm dia
Butterfly Valve 80 mm dia
Butterfly Valve 50 mm dia
Non Return Valves 80 mm dia.
Pot Strainers 100 mm dia
Needle Valve 25 mm dia
Pressure Gauge
Thermometer
Allen key Set and Two Manometer
Chilled water circulation Supply, laying, fixing, testing and commissioning of Chilled water water piping with MS ERW class ' C' pipe (Heavy conforming to IS-1239-1958), complete with all accessories such as bends, elbows, flanges, nut-bolts, air purging valves, descaling valves. The piping shall be laid overhead in plant and underground outside the plant room as per site conditions of following sizes :-
100 mm dia
65 mm dia
Supply, laying, fixing, testing and commissioning of Butterfly Valve Heavy duty (conforming to IS-1239-1958 and 3589-1958), complete with all accessories such as bends, elbows, flanges, nut-bolts of following sizes :-
100 mm dia
65 mm dia
Supply, laying, fixing, testing and commissioning of Balancing Valve Heavy duty (conforming to IS-1239-1958 and 3589-1958), complete with all accessories such as bends, elbows, flanges, nut-bolts, of following sizes :-
100 mm dia
65 mm dia
Supply, laying, fixing, testing and commissioning of Non Return Valve Heavy duty (conforming to IS-1239-1958 and 3589-1958) complete with all accessories such as bends, elbows, flanges, nut-bolts, of 65 mm dia size complete all as specified and directed.
Supply installation testing and commissioning low density polyethylene drain pipes size 50 mm dia (LDPE) of pressure rating 4 Kg/cm² on walls/ceiling or laying in floors including fixing with pipe fittings and material complete all as specified and directed.
Supply, laying, fixing, testing and commissioning of 'Y' Strainer with MS class ' C' (Heavy conforming to IS-1239-1958), complete with all accessories such as bends, elbows, flanges, nut-bolts, air purging valves, decaling valves of 100 mm dia complete all as specified and directed.
Supply, laying, fixing, testing and commissioning of 3 way pressure Independent Balancing cum control valve along with actuator and step down transformer with temperature sensor with 3C x 1.5 sqmm control cable from AHU panel to 02 way valve assembly and controller complete all as specified and directed. Note:- (The valve should close 100% on stopping of AHU) of suitable capacity)
Supply, laying, fixing, testing and commissioning of Pot Strainers 100 mm dia complete all as specified and directed.
Supply, laying, fixing, testing and commissioning of Needle Valve 25 mm dia complete all as specified and directed.
Supply, laying, fixing, testing and commissioning of Pressure Gauge complete all as specified and directed.
Supply, laying, fixing, testing and commissioning of Thermometer complete all as specified and directed.
Supply, laying, fixing, testing and commissioning of Purge Valve complete all as specified and directed.
Supply, laying, fixing, testing and commissioning of Expansion below 100 mm dia complete all as specified and directed.
Insulation Supply installation testing and commissioning nitrile rubber insulation 25mm thick on chilled water piping of the following sizes:-
100 mm dia
65 mm dia
Supply installation testing and commissioning nitrile rubber insulation 25mm thick on butterfly valve of the following sizes:-
100 mm dia
65 mm dia
Supply installation testing and commissioning nitrile rubber insulation on balancing valve of the following sizes:-
100 mm dia
65 mm dia
Supply installation testing and commissioning nitrile rubber insulation on Non Return Valve of 65 mm dia size complete all as specified and directed.
Supply installation testing and commissioning nitrile rubber insulation 25MM thick on ‘Y’ Strainer of 100 mm dia size complete all as specified and directed.
Supply installation testing and commissioning nitrile rubber insulation 25mm thick on Pot Strainer of size 100 mm dia complete all as specified and directed.
Supply installation testing and commissioning nitrile rubber insulation 25 mm thick on 2 way valve of suitable capacity complete all as specified and directed.
Supply, Constructing, Installation, testing and commissioning PVC make-up water tank for cooling tower feed/makeup water 5000 liters. The job includes for make-up water connection from existing pipe line tapping etc and staging for the tank, head adequate to feed the cooling Tower basin as directed by Engineer in Charge complete all as specified and directed.
Supply, laying, fixing, testing and commissioning of closed Expansion Tank 500 liter with complete air separator, pressurization units including foundation and plateform, sediment separator, pressure switch, piping, valves, fittings & control panel complete all as specified and directed.
AIR HANDLING UNIT (AHU) RETURN AIR WASHER TYPE Design, Supply, Installation, testing and commissioning Factory made high static double skinned horizontal type Air Handling Unit 1 [AHU1] 36 TR 12000 CFM (Static Pressure 50WG)with 0.6mm thick pre coated outer skin & 0.6mm thick inner skin made out of GI sheet comprising of backward or forward curved centrifugal blowers of adequate capacity housed in blower section, 3 phase squirrel cage induction motor adequate capacity TEFC type complete with motor pulleys with V-belts. Coil section with cooling coil multi row deep copper tubes with multi row deep with hydraulically bounded sine wave A1 fins tested for17 Kg/Sqcm pressure Filter section complete with cleanable type prefilter metallic type having efficiency 90% down to 10 micron. The make of cooling coils will be as per manufacturer of AHU. The insulation with 25mm thick PUF panels. The AHUs will be floor mounting with anti vibration pads for cooling the air with all accessories and controls comprising the following including painting etc as per standard practice:- INDOOR TYPE
[a] Chilled water cooling coil 8 Row with copper tubes not less than 0.5mm thickness and 13mm over all diameter 10 to 12 aluminium fins per inch. [b] Micro Vee filters having dust filtration capacity of 5 microns and above down to 95%suitable to requisite static pressure with Belt drive flame proof squirrel cage inductionmotor TEFC, 415V, 3 phase, 50 Hz, AC supply class ‘B’ insulation. [c] Electrically controlled / operated controls such as humidistat and thermostat along with all equipment and accessories connection to AHU as per design requirement. [d] Self removable panels with thermal and acoustic insulation. [e] Sloped bottom to collect humidification and condensate water for draining and drain piping of sufficient size and length as per standard practice. [f] Plenum to house micro vee filters and conical section to connect ducting with flexible ducting (canvas). (g) Acoustic insulation shall be with suitable thickness (not less than 19 mm) elastomeric Nitrile Rubber Open Cell Foam from the mouth of the AHU upto appropriate length as per standard practice. (h) Control for AHU with blower motor, heating thermostat, humidistat etc., with all accessories shall be deemed to be included as per manufacturer’s specifications.
Ditto all as per item No 127.00 here in before but Air Handling Unit [AHU-2] 40TR 13000 CFM complete all as specified and directed.
Supply, fabrication, installation, testing and commissioning of galvanised steel sheet (G.S.S.) ducting in square/ rectangular shape fabricated from galvanised steel sheet of following gauge galvanized sheet steel having zinc coating of 120 gm/sq.m total on both sides complete with gaskets, elbows, splitters, vanes, supports etc. as per IS: 655/1963 (Revised upto date) all as specified and including with required scafolding work to install the ducts at site complete all as specified and directed.
24 Gauge
22 Gauge
Supply, fabrication, installation, testing and commissioning of galvanised steel sheet (G.S.S.) return air ducting in square/ rectangular shape fabricated from galvanised steel sheet of following gauge galvanized sheet steel having zinc coating of 120 gm/sq.m total on both sides complete with gaskets, elbows, splitters, vanes, supports etc. as per IS: 655/1963 (Revised upto date) all as specified and including with required scafolding work to install the ducts at site complete all as specified and directed.
24 Gauge
22 Gauge
Supply, laying, fixing, testing and commissioning of Supply Air Diffuser With Volume Control Damper of following size in mm :-
Supply, laying, fixing, testing and commissioning of Return Air Diffuser With Volume Control Damper of following size in mm :-
Supply, laying, fixing, testing and commissioning of Supply Air Grill with Volume Control Damper of following sizes in mm :-
Supply, laying, fixing, testing and commissioning of Return Air Grill with Volume Control Damper of following size in mm:-
Supply, laying, fixing, testing and commissioning of Fire Dampers with Fusible link of following sizes in mm:-
Humidifier Supply install testing and commissioning of pan humidifier for winter season with connecting pipe with all accessories, valves etc. from tank with necessary heaters and connection wiring complete with humidistat of 5KW (for AHU 1 & 2) complete all as specified and as directed .
Supply, Install, Testing and Commissioning of thermostats, humidistat and Air stat for monsoon/winter condition complete all as specified and as directed .
Supply, Installation, Testing and Commissioning of Thermal Insulation for Inside Supply air ducting with 19mm thick closed cell elastrometric Nitrile rubber with factory laminated aluminium foil of density minimum 43Kg/m3 and fire perfromance to pass Class 1 as per BS 476 Part 7 & class O as per BS 476 part 6 and use recommended adhesives / SR Fevicol 505 grade and finished with 0.05 mm thick 3 " wide aluminium foil faced self adesive tape at all joints as per the specifications and approved drawings complete all as specified and directed.
Supply, Installation, Testing and Commissioning of ACCOUSTICl Insulation for Supply air ducting with 13 mm thick OPEN cell elastrometric Nitrile rubber and fire perfromance to pass Class 1 as per BS 476 Part 7 & class O as per BS 476 part 6 and use recommended adhesives / SR Fevicol 505 grade complete all as specified and directed.
Supply, Installation, Testing and Commissioning of Thermal Insulation for Inside return air ducting with 19mm thick closed cell elastrometric Nitrile rubber with factory laminated aluminium foil of density minimum 43Kg/m3 and fire perfromance to pass Class 1 as per BS 476 Part 7 & class O as per BS 476 part 6 and use recommended adhesives / SR Fevicol 505 grade and finished with 0.05 mm thick 3 " wide aluminium foil faced self adesive tape at all joints as per the specifications and approved drawings complete all as specified and directed.
Supply, laying , fixing , testing & commisining of heater banks as per specification and in multi bank of following sizes:-
Heater bank as per specs. in multi bank 20 KW (in 4 banks)
Heater bank as per specs. in multi bank 25 KW (in 4 banks)
S&F Non-chemical type on-line scale preventor of suitable capacity of the 100 mm size complete all as specified and as directed. Make:- Scale Ban /Scale-X /Scale off /Scale guard
S&F Lockable Push button for cooling tower complete all as specified and as directed .
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts indoor type, factory made free standing, floor mounting, dust and vermin proof cubical type, CPRI approved make, LT panel fabricated from 2.0 mm Indoor type thick CRCA sheet duly compartmentalized for each switch gear , front and rear open-able ( front hinged opening) ,locking arrangement with chromium plated 19 mm dia locks ( min 2 Nos in each compartment), lifting lugs of suitable size on top, louvers and air vent gasket for natural air, `U` shape rubber gasket, voltmeter, ammeter, Frequency meter.
Cont... Panel should be anti corrosive coating and finally epoxy polyester powder coating of Siemens Grey shade (RAL-7032), Protection class IP 43, fully compartmentalized design with 4 Nos of bus bars made of copper of ETP grade suitable for 600 amps with suitable size of copper strip duly insulated with colour coded heat shrinkable sleeve and shall mounted on suitable size `F` class insulators made of non hygroscopic, non combustible, track resistance , high strength FRP/SMC/DMC material at an interval not more than 500 mm throughout the length of bus bars , including suitable aluminum earth strips conforming to IS with danger notice plate, necessary cable glands, cable connection with proper copper/ aluminum lugs. The cubical incomer MCCB as well as outgoing shall have copper TPN extension link of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension link of min 500 mm long supported on suitable size `F` class insulator to be provided for termination on incomer and outgoing cables. All interconnection between main bus bar as well as outgoing feeders shall be carried out with TPN copper bus bar of rating not less than 1.5 times rated capacity of individual out going feeders. The panel should be mounted on bottom channel of suitable size with proper mounting arrangement as directed by Engr-in-Charge leaving min 500 mm all around the panel board for movements all as specified with supply and fixing the following:-
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts indoor type, factory made free standing, floor/wall mounting, dust and vermin proof cubical type, CPRI tested, LT panel fabricated from 2.00 mm thick CRCA sheet , duly compartmentalized for each switch gear , front and rear open-able ( front hinged opening) ,locking arrangement with chromium plated 19 mm dia fancy locks ( min 2 Nos in each compartment), lifting lugs of suitable size on top, louvers and air vent gasket for natural air, `U` shape rubber gasket.
Cont... Panel should be anti corrosive coating and finally epoxy polyester powder coating of Siemens Grey shade (RAL-7032), Protection class IP 43, fully compartmentalized design with 4 Nos of bus bars made of copper of ETP grade for 400 amps with suitable size of copper strip duly insulated with colour coded heat shrinkable sleeve and shall mounted on suitable size `F` class insulators made of non hygroscopic, non combustible, track resistance , high strength FRP/SMC/DMC material at an interval not more than 500 mm through out the length of bus bars including suitable aluminum earth strips, with danger notice plate, necessary cable glands, cable connection with proper aluminum/ copper lugs, The cubical incomer MCCB as well as out going shall have copper TPN extension link of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension link of min 200 mm long supported on suitable side `F` class insulator to be provided for termination on incomer and out going cables. All interconnection between main bus bar as well as outgoing feeders shall be carried out with TPN copper bus bar of rating not less than 1.5 times rated capacity of individual out going feeders. The panel should be mounted on angle iron frame of size 40x40x5 mm and further mounted on PCC foundation and pedestal having min 300 mm all around the feeder pillar board for movements all as specified with supply and fixing the following:- (AHU 1 and AHU2)
Supply, installation, testing and commissioning of LT, automatic power factor correction (APFC) panel, factory made, weather, dust & vermin proof made out of 16 gauge CRCA steel sheet duly powder coated paint with metalised poly propylene (MPP) type capacitors bank, heavy duty of 50 KVAR with variable correction shall comprise of 02 Nos stepping (2x25 KVAR) consisting of following:
The panel shall have copper bus bar of suitable size, 3 phase and with neutral and with the following:- (a) MCCB, TP, 160 Amps (adjustable type), 25 KA – 01No (incoming) (b) Heavy duty Contactors suitable frequent operation having current limiting resistors suitable for capacitive switching of variable KVAR correction of superior specifications. (c) MCCB/MCBs 'C' curve for back up protection of capacity as required. (d) Microprocessor based intelligent APFC relay for controlling variable connection KVAR (e) Indication lamp RYB (LED type) with toggle switch – 03 Set (f) MPP type heavy duty capacitor bank consisting of suitable No of switching sequences, 3 phase, 415 volts suitable for 10% over voltage & 30% over current having loses less than 0.5 W /KVAR with discharge resistors. (g) Suitable Nos & rating of contractors as required. (h) Internal wiring of panel with stranded copper cable of suitable size. (j) The design of panel shall be got approved from GE before fabrication
S&F cable route / chilled water pipe route indicator made of 6mm thick/ 6 inch dia cast iron plate duly embedded with latest LT cable / Chilled water pipe/ Hot water pipe fix in angle in 25mm X 3mm of length 40 cm with fixed in foundation complete all as specified and directed. Note:- PCC & Excavation & Earth work will be measured and paid separately.
FIRE ALARM & DETECTION SYSTEM S&F detector complying with and type certified to EN -54 addressable type smoke detector photoelectric/optical with base with self built intelligence as per IS:11360 complete all as specified and directed.
S&F detector complying with and type certified to EN -54 addressable type heat detector photoelectric/optical with base with rate of rise cum fixed temperature as per IS:2175 complete all as specified and directed.
S&F of Annealed tin copper (ATC) conductor, PVC sheathed, unarmoured, FRLS cable with required termination glands,lugs etc complete all as specified and directed for following sizes:-
2 core 1.5 sqmm
2 core 2.5 sqmm
S&F stove enameled conduit of 20 mm dia fixed under wall / slab with necessary clamps etc complete all as specified & directed.
ARBORICULTURE Supply and planting of CASORAINA tree in 0.25 - 0.3 Mtr poly bags with height 1.5 Mtr to 1.8 Mtr including digging holes 1.2 Mtr dia x 1.2 Mtr deep in ordinary soil and refilling the same with the excavated earth mixed with manure or sluldge in the ratio 2:1 (02 parts of stacked volume of earth after reduction of 20% with 1 parts of stacked volume of sludge of manure after reduction by 80% flooding with water and removed of surplus soil complete all as specified and directed.
Ditto all as per item No 152.00 here in before but CANARYDATE PALM.
Ditto all as per item No 152.00 here in before but AMALTAS.
Ditto all as per item No 152.00 here in before but NEEM.
Ditto all as per item No 152.00 here in before but GULMOHAR.
Ditto all as per item No 152.00 here in before but KESIA.
Ditto all as per item No 152.00 here in before but KAMUJ.
Ditto all as per item No 152.00 here in before but ASHOKA.
Ditto all as per item No 152.00 here in before but JASMINE.
Ditto all as per item No 152.00 here in before but ALORTONIA.
Ditto all as per item No 152.00 here in before but BOTTLE BRUSH.
Ditto all as per item No 152.00 here in before but ROSE.
Ditto all as per item No 152.00 here in before but BUGENELLA.
Ditto all as per item No 152.00 here in before but BATTLE NUT.
NOTE FOR ITEM NO. 152.00 to 165.00 (i) Height of plant shall be measured from top of follage ( not from the isolated branch/leaf,main stem) to 150mm from top of root. (ii) Water will not be supplied by MES. Contractor has to make his own arrangement for watering to plants and grass. (iii) The rates quoted by the contractor deemed to include watering, maintenance of plants till 2 years after certified date of completion of work. (iv) During 2 years after completion if any plant is found dead, or not of satisfactory growth, plants of approved size and shape shall be provided without any extra cost to the state. Simillarly the grass shall also be replanted without any extra cost if no desired growth is achieved during the period of 2 years. (v) Supply and application of manure, sweet earth and pesticides, fertilizers, etc up to 2 years after completion shall deemed to be included in the quoted unit rate. (vi) Tenderer to note that 20% cost of quotation against these items shall be retained for 2 years after completion.In case of failure by the contractor to maintain the plants as above, the same shall be carried out by the department at his Risk and Cost and the expenditure shall be deducted from this retained amount. (vii) The plants shall be brought at site Six months before the date of completion of the work as per Work order.
Provn of MS tree guard 1.5 metre high above GL with MS wiremesh of size 78 x 37 mm and 2 mm dia of wire and MS angle iron 20 x 20 x 3 mm verticals (3 No's) & MS flats 14 x3 mm around the tree guard (3 No's) (top, middle and bottom) equally spaced and embedded vertical angles in PCC 1:3:6 type C-1 including excavation in post holes and removal of excavated materials to a distance n exc 50 metre and applying two coats of synthetic enamel paint including one coat of red oxide primer to tree guards complete all as specified and directed.
Provision of services for operation of HAVC plant installed at AC plant of capacity upto 78 TR (2x39 TR + 1x39 TR standby) under this contract of Provision of surgical and medical ward at Ahemdabad including all spporting equipment such as chillers, condensors, all type of pumps and motors, panels, cooling tower, AHU, insulating ducts, fan and all types of valves etc in 03 shifts of 08 Hrs 11 months each (round the clock including sunday / holidays) by deploying technically qualified person after completion of Phase - 1 of Provision of surgical and medical ward at Ahemdabad contract including reliver as specified and directed. Notes for Item No 167.00 (i) The contractor shall employ one operator per shift. The operator shall be qualified & experienced in field and experience not less than 2 years in the same field. (ii) Cost of the periodical maintanance of various equipments / parts shall be deemed to be included in quoted rate of respective items. (iii) Desired temerature shall be maintained as per design of equipment. (iv) The contractor shall strictly follw the operation and maintanance manual of the plant. (v) Periodic cleaning and manintanance including removal of algae from cooling tower. (vi) Temperature and humidity measurement equipment to be provided. (vii) To maintain temperature in all place and area to be keep neat and clean. (viii) The log sheet must be maintain by the contractor including provision of required printed log sheet book as directed.
For first 11 months
For next 11 months to 22 months
PROVISIONAL LUMP SUM (PLS) Provide Provisional lump sum for (a) Construction of Rain Water Harvesting Pit-2 Nos
NOTE FOR ITEM NO 168.00 : - 1) Provisional lump sum shall be expended wholly or in parts as directed by GE. The works under Provisional Lump Sum shall be measured and paid for at applicable rates in MES SSR 2010 Part-II subject to percentage ( + or - denomination) computed under last column of this schedule above/below the provisional lump sum price worked out by the MES. (2) For details refer relavent TD drawings.
A2Z ENGINEERS AND PILE FOUNDATIONS
Jeet Construction
M/S ALPHA CONSTRUCTIONS
AFSON ENGINEERS & CONTRACTORS
M/s L. K. Agarwal
DHARIWAL TRADERS PRIVATE LIMITED
SANKALP INFRACON
KHETA RAM RAGHUNATH RAM CONST CO PVT LTD
Hariom Projects Pvt Ltd
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .