Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | NATIONAL ELECTRICALS JV L-1₹4.7 CrAccepted-AOC | ₹4.7 Cr | L-1 | Accepted-AOC Awarded being valid and eligible L1 Bidder |
| 2 | L-2₹5.1 Cr+₹39.0 L (8.26%)Rejected-Finance QTR NO 1B 43 STAFF COLONY PO JAMUNA COLLIERY DISTT ANUPPUR M P 484444 | ANUPPUR | MADHYA PRADESH | 484444 | ₹5.1 Cr+₹39.0 L (8.26%) | L-2 | Rejected-Finance Rejected on not being L-1 bidder as per Tender Committee Recommendation |
| 3 | L-3₹6.0 Cr+₹1.3 Cr (28.0%)Rejected-Finance | ₹6.0 Cr+₹1.3 Cr (28.0%) | L-3 | Rejected-Finance Rejected on not being L-1 bidder as per Tender Committee Recommendation |
Tender Value
₹6.4 Cr
EMD Value
₹8.1 L
Closing Date
12 Dec 2023, 5:00 pmClosed
General Manager (Civil)/HOD, SECL, HQ, Bilaspur
Office of the GM (Civil)/HOD, 3rd Floor, SECL, HQ, Bilaspur, PIN-495006
Repair and maintenance work (Electrical) of different Colonies (Indira Vihar Colony, Vasant Vihar Colony and Nehru Shatabdi Nagar) of SECL HQ Bilaspur (For 02 yrs.).
2023_SECL_294078_1
GM(C)/SECL/BSP/e-T/TA/2023/65 Dated 18.11.2023
Open Tender
Electrical and Maintenance Works
Item Rate
730 days
IVC, VVC and NSN at SECL HQ Bilaspur
Repair and maintenance work (Electrical) of different Colonies (Indira Vihar Colony, Vasant Vihar Colony and Nehru Shatabdi Nagar) of SECL HQ Bilaspur (For 02 yrs.).
5 documents required · 5 mandatory
₹8.1 L
26 Feb 2024
21 Nov 2023
15 Dec 2023
21 Nov 2023
12 Dec 2023
22 Nov 2023
21 Nov 2023 - 1 Dec 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group B
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 4 sq. mm + 2 X 4 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1 x 1.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 1.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 2.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 4 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 6 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 75 mm X 75 mm X 60 mm deep
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 100 mm X 100 mm X 60 mm deep
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 150 mm X 75 mm X 60 mm deep
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 180 mm X 100 mm X 60 mm deep
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 200 mm X 250 mm X 60 mm deep
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 250 mm X 300 mm X 100 mm deep
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
5/6 amps switch
2 way 5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Bell push
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
2 way 5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
4 Module (125mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm)
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Providing and fixing plain 16/0.20mm (0.50sqmm) twin flat flexible, FRLS PVC insulated, copper conductor cable, in PVC sleeve of suitable size on the floor/ wall, or side of the table/ door etc. as required.
Providing and fixing plain 16/0.20mm (0.50sqmm) twin circular flexible FRLS PVC insulated, PVC sheathed copper conductor cable direct on the wall with PVC clips etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Supplying and fixing PVC batten/ angle holder including connections etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
100 A, 16 KA,TPMCCB
200 A, 25 KA,TPMCCB
250 A, 35 KA,TPMCCB
400 A, 35 KA,TPMCCB
630 A, 50 KA,TPMCCB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 A
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95 sq. mm and upto 185 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3Y X 70 sq. mm (38mm)
3Y X 185 sq. mm (57mm)
4 X 16 sq. mm (28mm)
4 X 25 sq. mm (28mm)
4 X 35 sq. mm (32mm)
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3Y X 70 sq. mm
3Y X 95 sq. mm
3Y X 185 sq. mm
4 X 25 sq. mm
4 X 35 sq. mm
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 8.0 metre and upto 10.0 metre
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Erection of galvanised 'D' iron clamps and insulator on pole as required, as per instruction of Engineer I/c.
Erection of G.I. Wire No. 8 SWG including binding etc. as required, as per instruction of Engineer I/c
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and paint etc. as required.
Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
Excavation for cable trenches of depth upto 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres.
Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres.
Providing and laying in position cement concrete 1:3:6 (1 cement : 2 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 50 mm dia
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 80 mm dia
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 100 mm dia
Painting with one or more coat of synthetic enamel paint of approved brand and manufacturer of required colour to give an even shade. (DSR Civil-2014, Item no. 14.54)
Painting with one or more coat of aluminium paint of approved brand and manufacturer to give an even shade. (DSR Civil-2014, Item no. 14.55)
Providing and fixing of 3 mm thick phenolic laminated sheet of different sizes as per requirement for fixing of switch socket etc on existing board as per instruction of Engineer I/c
Providing and fixing of PVC Board 4x4 as per instruction of Engineer I/c
Providing and fixing of PVC Board 4x7 as per instruction of Engineer I/c
Providing and fixing of PVC Board 6x8 as per instruction of Engineer I/c
Providing and fixing of PVC Board 8x10 as per instruction of Engineer I/c
Providing and fixing of 3 pin top 5 Amp, 230V as per instruction of Engineer I/c
Providing and fixing of LED bulb 12 Watt as per instruction of Engineer I/c
Providing and fixing of globe size 300mm with 9 W LED lamp as per instruction of Engineer in Charge.
Providing and fixing of globe size 250mm with 9 W LED lamp as per instruction of Engineer I/c
Providing and fixing of LED Down lighter 3W as per instruction of Engineer in Charge.
Providing and fixing of LED Outdoor Fitting 20 Watt as per instruction of Engineer in Charge.
Providing and fixing of Bracket for LED Outdoor Fitting as per instruction of Engineer in Charge.
Providing and fixing of rewirable porcelin fuse & Base, 250V, 16A as per instruction of Engineer I/c
Providing & fixing of Outdoor type Bus Bar in steel sheet encloser 4 pole 250 Amp, 415V including with MS angle stand size as per requirement as per instruction of Engineer I/c
Providing & fixing of Outdoor type Bus Bar Bar in steel sheet encloser 4 pole 400 Amp, 415V including with MS angle stand size as per requirement as per instruction of Engineer in Charge.
Providing and fixing of Busbar Bar in steel sheet encloser 100A, 440V, 4 pole size as per requirement as per instruction of Engineer in Charge.
Providing and fixing of Busbar Bar in steel sheet encloser 63A, 440V, 4 pole size as per requirement as per instruction of Engineer in Charge.
Providing and fixing locking arrangement for main switch and switch boards/main and branch distribution boards in an approved type of iron frame with shutter in position including painting. Finishing etc. as required complete. as per instruction of Engineer I/c
Providing and fixing of Exhaust Fan 230V, 380 mm as per instruction of Engineer in Charge.
Providing and fixing of Exhaust Fan 230V, 450 mm as per instruction of Engineer I/c
Providing and fixing of Wall Bracket Fan 230V, 400 mm as per instruction of Engineer I/c
Providing and fixing of Pedestal Fan 230V, 400 mm as per instruction of Engineer in Charge.
Providing and fixing of Air break Switch 3 pole, 800 AMP, 11KV Grade as per instruction of Engineer in Charge.
Providing & fixing of HRC Fuse Base DIN Type Size 00 ,63-160 Amp, 415V as per instruction of Engineer in Charge.
Providing & fixing of HRC Fuselink DIN type Size 00 ,63 Amp, 415V as per instruction of Engineer in Charge.
Providing & fixing of HRC Fuse Base DIN type Size 1 ,80-250 Amp, 415V as per instruction of Engineer in Charge.
Providing & fixing of HRC Fuse link DIN type Size 00 ,160 Amp, 415V as per instruction of Engineer in Charge.
Providing and fixing of ML-2 Contactor as per instruction of Engineer in Charge.
Providing and fixing of ML-3 Contactor as per instruction of Engineer in Charge.
Providing and fixing of Ml-4 Contactor as per instruction of Engineer in Charge.
Providing and fixing of Anologue Timer for Street lighting as per instruction of Engineer in Charge.
Rewinding of Ceiling Fan Sweep (1200/ 1400mm) of different make with copper wire of approved quality as per instruction of Engineer in Charge.
Rewinding of Exhaust fans , Single phase 15" as per instruction of Engineer in Charge.
Rewinding of Exhaust fans , Single phase 18" as per instruction of Engineer in Charge.
Providing and fixing of Capacitor 2.5mfd for ceiling Fan as per instruction of Engineer in Charge.
Providing and fixing of capacitor 3.15 Mfd charges for Exhaust fans as per instruction of Engineer in Charge.
Providing and fixing of Bearing 6202 for ceiling Fan as per instruction of Engineer in Charge.
Providing and fixing of Bush Replacement of Gun Metal with machining as per instruction of Engineer in Charge.
Providing and fixing of LED Tube Light 22 W, 230V, 4 Feet as per instruction of Engineer in Charge.
Providing and fixing of encloser for MCCB 100A. as per instruction of Engineer I/c
Providing and fixing of 3 pin top 15/16 Amp,230V as per instruction of Engineer I/C
Providing and fixing of Pole terminal box 3PIN with 01 no. rewirable Kitkat fuse 16 A , size 200x150x100mm and 50mm GI pipe Medium class of 1.5 Mtr length with thread and 02 nos. checknut with rubber washer, cable entry & exit hole in box (water tight) as per instruction of Engineer in Charge.
Providing and fixing of 15W LED Fitting,230V surface/recess Round Shape as per instruction of Engineer in Charge.
Providing and fixing of PVC Board 10x12 as per instruction of Engineer in Charge.
Providing and fixing of Exhaust Fan 230V, 300 mm as per instruction of Engineer in Charge.
Providing and fixing of SS Combined 16A, 230V, 6 pin as per instruction of Engineer in Charge.
Providing PVC Tape 18mm self adhesive for electrical work as per instruction of Engineer I/c
Providing Rubber tape for Cable repairi/jointing work. as per instruction of Engineer I/c
Providing and fixing of 3 core 4 sqmm copper cable for submersible pump as per instruction of Engineer I/c
Providing & fixing of Rope/Strip light LED for false ceiling as per instruction of Engineer in charge
Providing & Fixing of LED panel 22W Round/square shape with cutting of false ceiling complete as per instruction of Engineer in charge
Providing & Fixing of LED panel 18 W Round/square shape with cutting of false ceiling complete as per instruction of Engineer in charge
Providing & Fixing of LED panel 8W Round/square shape Surface/Recess complete as per instruction of Engineer in charge
Providing and fixing of LED light fitting 2'x2' , 36 Watt as per instruction of Engineer in Charge.
P & F of Casing patti/caping 1/2" as per instruction of Engineer I/C
P & F of Casing patti/caping 1" as per instruction of Engineer I/C
P & F of Casing patti/caping 1-1/2" as per instruction of Engineer I/C
P & F of Gang box 1way/ 2 way as per instruction of Engineer I/C
P & F of Gang box 3way as per instruction of Engineer I/C
P & F of Gang box 4 way as per instruction of Engineer I/C
P & F of Gang box 6 way as per instruction of Engineer I/C
P & F of Ammeter 96x96 , 0-50 A as per instruction of Engineer I/C
P & f of Voltmeter 96x96, 500 V as per instruction of Engineer I/c
P & F of LED Indicating Lamp RGYB as per instruction of I/C
P & F of ICTP 63 A , 440V as per instruction of Engineer I/C
Contractual manpower assistance for operation, maintenance & petty work of Substation , residential & non residential Buildings at IVC, VVC , NSN & Manin & Old Administrative building of SECL HQ Bilaspur. as per instruction of Engineer I/c ( 9 nos. wireman/electrcician , 12 nos. electrician, 15 nos. Khalashi ).
Supply of Kit Kat Fuse 63A, 500V as per instruction of Engineer I/C
Providing Electrical Rubber Insulating Mat 11KV grade 2.5mm thick 1 Mtr width as per instruction of Engineer I/C
Lighting decoration of front elevation area of the following building / structure shall be illuminated as below - Top belt having running effect consisting of bulbs of 6 Volt on top of the building & vertical series 5 Meter Long spaced @ 0.5 Meter consisting of 45 to 50 bulbs of 6 volt in each series including cost of labour and material all complete as per instruction of Engineer incharge, Priydarsni Bhawan one side only
Lighting decoration of front elevation area of the following building / structure shall be illuminated as below - Top belt having running effect consisting of bulbs of 6 Volt on top of the building & vertical series 5 Meter Long spaced @ 0.5 Meter consisting of 45 to 50 bulbs of 6 volt in each series including cost of labour and material all complete as per instruction of Engineer incharge, -Mahanadi club Vasant Vihar Colony one and half side
Lighting decoration of front elevation area of the following building / structure shall be illuminated as below - Top belt having running effect consisting of bulbs of 6 Volt on top of the building & vertical series 5 Meter Long spaced @ 0.5 Meter consisting of 45 to 50 bulbs of 6 volt in each series including cost of labour and material all complete as per instruction of Engineer incharge, Narmada Club one and half side
Lighting decoration of front elevation area of the following building / structure shall be illuminated as below - Top belt having running effect consisting of bulbs of 6 Volt on top of the building & vertical series 5 Meter Long spaced @ 0.5 Meter consisting of 45 to 50 bulbs of 6 volt in each series including cost of labour and material all complete as per instruction of Engineer incharge, Aprajita Bhawan
Lighting decoration of front elevation area of the following building / structure shall be illuminated as below - Top belt having running effect consisting of bulbs of 6 Volt on top of the building & vertical series 5 Meter Long spaced @ 0.5 Meter consisting of 45 to 50 bulbs of 6 volt in each series including cost of labour and material all complete as per instruction of Engineer incharge - Vasant Vihar Dispensary
Lighting decoration of front elevation area of the following building / structure shall be illuminated as below - Top belt having running effect consisting of bulbs of 6 Volt on top of the building & vertical series 5 Meter Long spaced @ 0.5 Meter consisting of 45 to 50 bulbs of 6 volt in each series including cost of labour and material all complete as per instruction of Engineer incharge - IVC Dispansary
Lighting decoration of CMD Bungalow , Directors Bungalow, CVO bungalow- by LED Jhhalar, Running Patti, Rope light in Buagalow, Garden, gate, Boundary etc as per direction of Engineer I/c
Lighting decoration on different occation at Vasant club, Ravindra Bhawan , Sawan jhoola chrismas for inside decoartion by LED Jhhalar, Running Patti, Rope light etc as per direction of Engineer I/c
Motor Pump Repairing
6312 Ball Bearing changing fitting on Motor (DE/NDE) as per instruction of Engineer I/c
Rotor Cleaning, brazing and Balancing work upto 50HP Motor as per instruction of Engineer I/c
Rotor Bearing sheet welding, turning polishing work as per instruction of Engineer I/c
Motor rewinding 40 HP, 3 Phase, 415V complete (removal of stator burnt winding , cleaning of stator core, Copper rewinding, insulation varnising, lead making & conectionn, testing etc) (Windind Shall be done with PVC insulated/ enemelled copper wire size as per original winding data) as per instruction of Engineer I/c
Motor rewinding 50 HP, 3 Phase, 415V complete (removal of stator burnt winding , cleaning of stator core, Copper rewinding, insulation varnising, lead making & conectionn, testing etc) (Windind Shall be done with PVC insulated/ enemelled copper wire size as per original winding data) as per instruction of Engineer I/c
6310 Ball Bearing changing fitting on Motor (DE/NDE) as per instruction of Engineer I/c
Cenrtrifugal Pump Opening and fitting charge 30 HP pump as per instruction of Engineer I/c
6307 Ball Bearing changing fitting (DE/NDE) as per instruction of Engineer I/c
Replacement of brass bush of 30HP pump. as per instruction of Engineer I/c
Motor opening , cleaning testing & fitting 25HP/30HP/40HP/50HP as per instruction of Engineer I/c
Brass neckring & checknut changing as per instruction of Engineer I/c
Providing Motor Pump Base plate with allignment work for 30 HP centrifugal pump motor set as per instruction of Engineer I/c
Submerssible Motor pump rewinding 5 HP, 3 Phase, 415V complete with repairing of pump (moor & pump side opening, removal of stator burnt winding , cleaning of stator core, Copper rewinding, insulation varnising, lead making & conectionn, testing, pump impeller welding,turning, etc) (Windind Shall be done with PVC insulated/ enemelled copper wire size as per original winding data) as per instruction of Engineer I/c
Submewrsibble Motor pump rewinding 7.5 HP, 3 Phase, 415V complete (moor & pump side opening, removal of stator burnt winding , cleaning of stator core, Copper rewinding, insulation varnising, lead making & conectionn, testing, pump impeller welding,turning, etc) (Windind Shall be done with PVC insulated/ enemell ed copper wire size as per original winding data) as per instruction of Engineer I/c
Submewrsibble Motor pump rewinding 10 HP, 3 Phase, 415V complete (moor & pump side opening, removal of stator burnt winding , cleaning of stator core, Copper rewinding, insulation varnising, lead making & conectionn, testing, pump impeller welding,turning, etc) (Windind Shall be done with PVC insulated/ enemelled copper wire size as per original winding data) as per instruction of Engineer I/c
Submewrsibble Motor pump rewinding 17.5 HP, 3 Phase, 415V complete (moor & pump side opening, removal of stator burnt winding , cleaning of stator core, Copper rewinding, insulation varnising, lead making & conectionn, testing, pump impeller welding,turning, replacement of thrust bearing , Gun metal bush etc) as per instruction of Engineer I/c
Lowering of Submersible Pump upto 20 HP as per instruction of Engineer I/c
Lifting of BD Subemersible Pump upto 20 HP as per instruction of Engineer I/c
Openwell Motor pump rewinding 5 HP, 3 Phase, 415V complete with repairing of pump (moor & pump side opening, removal of stator burnt winding , cleaning of stator core, Copper rewinding, insulation varnising, lead making & conectionn, testing, pump impeller welding,turning, etc)(Windind Shall be done with PVC insulated/ enemelled copper wire size as per original winding data) as per instruction of Engineer I/c
Openwell Motor pump rewinding 7.5 HP, 3 Phase, 415V complete with repairing of pump (moor & pump side opening, removal of stator burnt winding , cleaning of stator core, Copper rewinding, insulation varnising, lead making & conectionn, testing, pump impeller welding,turning, etc) (Windind Shall be done with PVC insulated/ enemelled copper wire size as per original winding data) as per instruction of Engineer I/c
MonoBlock Motor pump rewinding 10 HP, 3 Phase, 415V complete with repairing of pump (motor & pump side opening, removal of stator burnt winding , cleaning of stator core, Copper rewinding, insulation varnising, lead making & conection, testing, pump impeller welding,turning, welding & repairing of Base plate, Changing of Bearing, Bushing, Sim, Checknut,etc) (Windind Shall be done with PVC insulated/ enemelled copper wire size as per original winding data) as per instruction of Engineer I/c
Motor rewinding 25 HP, 3 Phase, 415V complete (removal of stator burnt winding , cleaning of stator core, Copper rewinding, insulation varnising, lead making & conectionn, testing etc) (Windind Shall be done with PVC insulated/ enemelled copper wire size as per original winding data) as per instruction of Engineer I/c
Repairing of Pump Shaft 50HP/40HP/30HP including repalcement of brass bar (shaft sleeve)complete set as per instruction of Engineer I/c
Motor rewinding 30 HP, 3 Phase, 415V complete (removal of stator burnt winding , cleaning of stator core, Copper rewinding, insulation varnising, lead making & conectionn, testing etc) (Windind Shall be done with PVC insulated/ enemelled copper wire size as per original winding data) as per instruction of Engineer I/c
Openwell Motor pump rewinding 10 HP, 3 Phase, 415V complete with repairing of pump (motor & pump side opening, removal of stator burnt winding , cleaning of stator core, Copper rewinding, insulation varnising, lead making & conectionn, testing, pump impeller welding,turning, etc) (Windind Shall be done with PVC insulated/ enemelled copper wire size as per original winding data) as per instruction of Engineer I/c
Pump Side opening , cleaning testing & fitting 25HP/30HP/40HP/50HP as per instruction of Engineer I/c
Providing & Fixing of Gland Packing as per instruction of Engineer I/c
Openwell Motor pump rewinding 3 HP/2 HP/ 1HP, 3 Phase, 415V complete with repairing of pump (motor & pump side opening, removal of stator burnt winding , cleaning of stator core, Copper rewinding, insulation varnising, lead making & conectionn, testing, pump impeller welding,turning, etc) (Windind Shall be done with PVC insulated/ enemelled copper wire size as per original winding data) as per instruction of Engineer I/c
Geyser Repairing Work
S & F of Geyser Element 2 KW as per instruction of Engineer I/c
S & F of geyser thermostate temp setting 0-75 c as per instruction of Engineer I/c
S & F of Inlet & Outlet U Bend Copper pipe as per instruction of Engineer I/c
S & F of Nut & washer complete for inlet & outlet pipe as per instruction of Engineer I/c
Opening & Fitting charges for geyser as per instruction of Engineer I/c
Cleaning of Geyser for calcium removal/ acid cleaning as per instruction of Engineer I/c
P & F of Fountain LED light fitting assly as per instruction of Engineer I/c
P & F of Chasser for Fountain LED light fitting as per instruction of Engineer I/c
Total impact of GST for the purpose of CTC
bsreddy
ELECTRONIC INDIA
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .