Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 184 KEELA STREET NEIKULAM NEDUNGUR LALGUDI 621105 | TIRUCHIRAPPALLI | TAMIL NADU | 621105 | Admitted-Finance |
Tender Value
₹42 L
EMD Value
₹42,000
Closing Date
25 Feb 2025, 3:00 pmClosed
Commissioner
Azad Road,Karur
Lifting, rerection and Servicing and cleaning of column pipe, shaft, retainer, discharge head and bowl assembly for vertical turbine pump sets,165 HP flushing of 300 mm dia radial arms,porviding new MV panel in KFW- HW Karur Corporation
2025_MAWS_525179_5
E1/5531/2024
Open Tender
Civil Works
Item Rate
120 days
KCMC
Refer Tender Documents
3 documents required · 3 mandatory
₹0
₹42,000
Yes
21 Mar 2025
18 Feb 2025
25 Feb 2025
18 Feb 2025
25 Feb 2025
18 Feb 2025
18 Feb 2025 - 25 Feb 2025
Amount
Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in units of (kilolitres/ cubicmeter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3m/sec to 4 m/sec and be constructed as follows:Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects Coil Housing shall be fabricated from stainless steel (SS 304) with Anticorrosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP 68 protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions.The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output, Communication interface is RS485, HART output, . The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out Higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminium with glass window. The converter cum transmitter should be fully programmable form the front facia. The programming should be user friendly, self-prompting menu driven. Flowmeter test calibration certificate from FCRI, flow test lab/ NABL accredited lab to be furnished.
400 mm dia
Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to with IS-638(1979) and M.S. bolts and nuts of IS 1364-1 (2002), including cost of jointing materials such as bolt and nuts Rubber insertion and labour charges etc., complete. flow meter erection
400 mm dia
supply and delivery of630A, 4 Pole 50kA, Microprocessor Based, EDO Breaker
Supply and delivery of Automatic Power Factor Capacitor Panel the following site
Supply and delivery following electrical material as directed by the departmental officers
Digital Ammeter 3 phase
Digital Voltmeter 3 phase
Cable Route Indicator for LT Cable
2m x 1m Rubber Mat suitable for 11 KV installation confirming to IS
First Aid Box complete with all First Aid Medicines
Fire Extinguisher Co2, 4.5 kg. confirming to TAC Norms
Earth Discharge Rod
250 Amps Three Phase 4 Pole Change Over Switch
Supply and delivery of floor / wall mounting type weather vermin and dust proof powder coated LT cubical panel board MS sheet and MS angle iron frame work . The bus bars shall be of ample current carrying capacity with all internal wiring as per I.E rules and as per IS 8633 and as per safety requirement of CEIG. Incomer : 1 No - 600 amps ACB Out going : 2 Nos - 500 amps ACB Out going : 2 Nos - 200 amps ACB 1 No - 100 amps TPN fuse switch Metering : digital volt meter, digital ammeter indication lamps , control fuses etc. complete
Supply and delivlery 16.0 sq.mm of PVC Insulated And Sheathed 3 Core Flat Type Copper Cable Conforming To Is 694/1990 And As Amended Thereafter
Providing 16.0 sq.mm cable laying as directed by departmental officer
White washing two coats using the screened shell lime as directed by the TWAD Board Officers.
Painting two coats with approved cement paint of approved quality colours for the new plastered surface of the pumphouse outside wall as directed by departmental officers including cleaning, preparing the surface for curing etc. complete
L.T. Cables 3.5 core 1.1 kv grade armoured aluminium conductor cross linked poly ethylene insulated pvc sheathed cables conforming to is 7098 (part i)/1988 and as amended thereafter with ISI marking
Servicing of starter both electrical and mechanical equipments including testing of healthiness of vaccum contactors and no load test and load test etc.complete.,as directed by the dept.officers
Supply and fixing of Main Element for 160 KVA Air filtter and Safty Element for 160KVA Air filtter Cleaner including Labour charges with necessary arrangements etc.complete.
Supply and filling of Coolant oil for 160KVA cummins(cat) /62.5KVA diesel Generator etc: complete
Servicing of Radiator for 160 KVA Generator: Charges for servicing of Radiator for 160 KVA Generator ( Make: cummins(cat) ) radiator core cleaning, and Decaling including welding with all labour charges etc;complete as directed by the departmental officer’s.
Charges for Servicing of Diesel pump Service for 160KVA Generator for servicing Make: cummins(cat) Diesel pump oil pump nozzle service and copper washer for diesel pump assembly Servicing of Radiator, Engine & Alternator General service charges etc, complete
Supply and fixing 12V, 130AH Heavy duty Battery (3years Warranty) with reputed make as per standard speech and connecting leads, legs bolt & nuts Including all Material and labour charges etc., complete as direct by the departmental officer.
Charges for BDV test and acidity test for transformer oil The oil sample taken from transformer conservative tank to submitted and obtaining the oil BDV test report. Oil filtration of existing oil by using mobile filtration machine including cost of genset for Temperary power supply labour and transportation etc complete as directed by the departmental officers .
Repalacing of silica gel breather from the transformer and filling the new silica gel and re fixing the same including cost of all materials all labour charges etc complete as directed by the departmental officers .
Charges for cleaning free from rust and painting with two coats of best synthetic enamel paint of aluminium colour to 11 KV consumer double pole (DP) structure metal parts and transformer yard fancing and synthetic enamel painting of RYB colour to jumpers and synthetic enamel painting of gray colory to yard fancing angles & gate including cost of all materials all labour charges etc complete as directed by the departmental officers .
Charges for 250 KVA transformer secondary side oil leakage arresting replacing and supply of brass stem - 1 set bush & packing sheet with necessary bolts and nuts including labour charges necessary temperary arrangements by the departmental officers .
Supply of transformer oil and top up to filling in conservator tank and complete insulation testing of both side ( primary & secondary side ) of winding by using megger testing etc., complete as directed by the departmental officers .
Charges for cleaning free from rust and painting with two coats of best synthetic enamel paint of Aluminium colour to 11KV consumer double pole ( DP) structure ,metal parts, and Transformer yard fencing ,and synthetic enamel painting of RYB colour to jumpers and synthetic enamel painting of gray colour to yard fencing angles & gate including cost of all materials , all labour charges. etc; complete as directed by the departmental officers.
Supply and fixing of EB main panal outside damage bush & packing sheet with necessary bolts and nuts including labour charges necessary temperary arrangements by the departmental officers .
ASV CONSTRUCTION (BID ID -1257421)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .