EXECUTIVE ENGINEER
MAINTENANCE UNIT, SHAKTI BHAWAN EXTN. LUCKNOW
AMC OF AIR CONDITIONERS INSTALLED IN SHAKTI BHAWAN HQ AND SHAKTI BHAWAN EXTN. BUILDING LUCKNOW
2021_UPPCL_570452_1
60/MU/SBE/2020-21
Open Tender
Air-Conditioner
Item Rate
365 days
SHAKTI BHAWAN LUCKNOW
PLEASE REFER TO TENDER DOCUMENT
2 documents required · 2 mandatory
₹3,540
EXECUTIVE ENGINEER MAINTENANCE UNIT, SBE, LKO
₹20,000
17 Aug 2021
15 Mar 2021
1 Apr 2021
15 Mar 2021
31 Mar 2021
16 Mar 2021
Amount
Replacement of dameged sealed compressor by factory repaired & sealed compressor of same model along with certificate of the company. This work include removing the dameged compressor from the window split A.C. by cutting & installing the factory repaired any leckage and pressure testing replacement capillary filter as required all complete including adjustment of Damaged Material Cost.
a. 2.0 Ton Window Type Air-conditioner. (SB(HQ)-09 + SBE-10=19)
b. 1.5 Ton Window Type Air-conditioner. (SB(HQ)-12 + SBE-30=42)
c.1.5 Ton Split Type Air-conditioner. (SB(HQ)-00 + SBE-12 =12)
d. 2.0 Ton Split Type Air-conditioner. (SB(HQ)-09 + SBE-10=19)
Replacement of damaged wiring kit . (SB(HQ)-36 + SBE-50=86)
Gas & Gas charging replacement of capillary filter repairing of leakage and pressure testing.
a. 2.0 Ton Window Type Air-conditioner. (SB(HQ)-09 + SBE-10=19)
b. 1.5 Ton Window Type Air-conditioner. (SB(HQ)-12 + SBE-36=48)
c. 2.0 Ton Split Type Air-conditioner. (SB(HQ)-16 + SBE-10=26)
d. 1.5 Ton Split Type Air-conditioner. (SB(HQ)-00 + SBE-12=12)
Replacement of thermostat including adjustment of damaged thermostat. (SB(HQ)-36 + SBE-40=76)
Replacement of defective relay including adjustment of damaged defective relay. (SB(HQ)-36 + SBE-40=76)
Replacement of damaged running capacitor including adjustment of damaged running capacitor. (SB(HQ)-45 + SBE-50=95)
Replacement of starting condenser including adjustment of damaged condenser. (SB(HQ)-27 + SBE-36=63)
Replacement of defective condenser coil of 2.0/1.5 ton window type A.C. including adjustment of damaged defective condenser coil. (SB(HQ)-09 + SBE-15=24)
Replacement of bush & shaft of blower fan of window A.C. including adjustment of damaged bush & shaft of blower fan. (SB(HQ)-36 + SBE-50=86)
Rewinding of blower fan motar of 2.0/1.5/1.0 Ton Air-conditioner including dismantling & installation of blower fan motor.
a. 2.0 Ton Window Type Air-conditioner. (SB(HQ)-10 + SBE-08=18)
b.1.5 Ton Window Type Air-conditioner. (SB(HQ)-14 + SBE-40=54)
Replacement of blade of fan motor of 2.0/1.5 Ton window A.c. including adjustment of damaged blade of fan motor.(SB(HQ)-17 + SBE-35=52)
Complete servicing of window/split Air-conditioner capacity 2.0/1.5/1.0 Ton capacity which include cleaning of fan, cooling coils, filter, lubrication of fans, checking of Electrical wiring etc. (SB(HQ)-190 + SBE-200=390)
Replacement of fan motor of A.C. Blower of split A.C. internal unit including adjustment of damaged blade of fan motor (SB(HQ)-09 + SBE-15=24)
Overhauling and servicing of 3.0 T capacity multi split unit. (SB(HQ)-02 + SBE-00=02)
Replacement of P.C.B. for non inverted type A.C’s including adjustment of damaged Old P.C.B.
a. 1.5 Ton window A.C.(SB(HQ)-00 + SBE-06=06)
b. 2.0 Ton window A.C.(SB(HQ)-00 + SBE-06=06)
c. 1.5 Ton split A.C.(SB(HQ)-00 + SBE-06=06)
d. 2.0 Ton split A.C.(SB(HQ)-00 + SBE-06=06)
M/S OM SERVICES
A M TRADRES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .