Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.4 LAccepted-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L1 | Accepted-AOC ACCEPTED BEING LOWEST QUOTED | |
| 2 | L2₹46.5 L+₹1.8 L (4.02%)Rejected-AOC | L2 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED | |
| 3 | L3₹46.9 L+₹2.2 L (4.85%)Rejected-AOC 00 VIDYUT NAGAR MEERANPUR SADDARALI TANDA AMBEDKAR NAGAR UTTAR PRADESH 224238 | AMBEDKAR NAGAR | UTTAR PRADESH | 224238 | L3 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED | |
| 4 | L4₹47.1 L+₹2.5 L (5.51%)Rejected-AOC | L4 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED | |
| 5 | L5₹47.4 L+₹2.8 L (6.19%)Rejected-AOC | L5 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
Tender Value
₹43.8 L
EMD Value
₹87,500
Closing Date
16 Aug 2021, 6:00 pmClosed
GE ARMY GANDHINAGAR
GE GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
PROVN OF WIRE MESH GRILL AND SLIDING WINDOW IN OTM ACCN AND SPECIAL REPAIR REPLACEMENT OF LT OH CONDUCTOR TO UG CABLE LT PANEL AND CONNECTED WORKS NEAR BLDG NO P 198 AT MIL STN GANDHIANGAR
2021_MES_464790_1
GE(A)/GNR/TOKEN/54 of 2021-22
Open Tender
Civil Works
Item Rate
180 days
MIL STN GANDHINAGAR
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE ARMY GANDHINAGAR
₹87,500
Yes
28 Sept 2021
3 Aug 2021
18 Aug 2021
3 Aug 2021
16 Aug 2021
10 Aug 2021
3 Aug 2021 - 9 Aug 2021
Amount
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for foundation of pole, laying of cables etc in soft/loose soil and getting out complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layer not exc 25 cm with soil obtained from excavation complete all as specified and directed.
M&L for providing dry river sand as in sand cushioning to UG cable including punning gently all as directed. Note: Depth after punning shall be measured and paid.
Removing excavated material (Soil) not exc 50 mtr and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.
M&L for plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundtion of PCC poles/struts all as specified and directed.
M&L for plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
Cutting holes into or through brick walls built in cement mortar in CM 1:3 or in cement concrete 1:2:4 Type B-1 and making good as required (superficial area n. exc 150 sq cm) all as specified and directed by Engineer - in - Charge.
M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for bed block/padestal/coping around poles, including necessary form work, finishing even and smooth without using extra cement, all as specified and directed.
M&L for cement concrete (1:2:4), type B0, using 12.5 graded stone aggregate in roof kerbs coving roof kerbs coving coved fillets of 75mm radius at junction bof roof slab and parapet wall , vertical surfaces and like etc complete all as specified and directed,
Supply and laying sub class old 'B' burnt bricks, size of brick 230x115x75mm, laid as cable protection cover complete all as specified and directed.
S&F, stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
M&L for mild steel framed work such as grills, gratings, etc. with ends of bars, shouldered and/or riveted, or forged into spikes, framed guard bars etc and similar work conforming to Fe-290 (Gde-E-165) including applying one shop coat of red oxide primer complete all as specified and directed
S&F mild steel work in weather shed posts, main and cross beams, hip and jack rafters, purlins, including special shaped washer etc. complete using ERW or induction butt welded tubes, conforming to IS 1161-1979, Gde St-240 complete all as specified and directed.
S&F, 2mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screws and washer in roof, wall etc complete all as specified and directed.
M&L for rendering cement plaster 10mm thick in cement mortar (1:6) on faie faces of brick work or concrete surfaces of walls, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering cement plaster 10mm thick in cement mortar (1:3) on fair faces of brick work or concrete surfaces of ceilling, chajjas, fins facia etc. finished even and smooth without using extra cement complete all as specified and directed.
M&L for cutting uneven surfaces of concrete & cutting reinforcement from drops of fins & facias (thickness not exceeding 50mm) using necessary scaffolding and making good the disturbed portion with 5mm thick rendering in CM 1:3 finished even and smooth without using extra cement etc. complete all as specifeid and directed.
M&L for preparing new plastered or un-plastered surfaces and applying two coats of oil bound distemper over a coat of chalk whitining on walls complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of white cement as primer complete all as specified and directed.
M&L for preparing new plastered or un-plastered ceiling surfaces and applying three coats of white wash complete all as specified and directed.
M&L for preparation of new steel surface of any description exc. 10cm width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed.
Demolition for Roof, floors (other than ground floors), beams, staircase, landing, chajjas and similar work suspended works etc complete all as specified and directed
S&F, in repair, LED type street light fittings, IP-66, 60 W, Pressure die cast aluminium housing with toughned glass & individual LEDs with secondary optics including taking out old unsv fitting of any type complete all as specified and directed.
S&F, in repair, PVC insulated and PVC Sheathed copper conductor cable of size 2.5 Sqmm, 3 core, 1100 volts grade, multstranded, passing through pipe, on pole/wall from junction box to street light fitting complete all as specified and directed.
Supplying & laying, 10 Sqmm, 4 core cable, XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete complete all as specified and directed.
Supplying & laying, 35 Sqmm, 3.5 core cable, XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete complete all as specified and directed.
Supplying & laying, 70 Sqmm, 3.5 core cable, XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete complete all as specified and directed.
Supplying & laying, 150 Sqmm, 3.5 core cable, XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete complete all as specified and directed.
Supplying & laying, 185 Sqmm, 3.5 core cable, XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete complete all as specified and directed.
Taking out existing serviceable LT Cable of any size and relaying for the same complete all the specified and directed. Note : Exavation and earth work will be measured and paid separately.
Taking down old PCC LT Poles and S&F, Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-22 (8.5 metres long) duly painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
S&F, in repair, LED bollard light of 10 Watt, IP-65 having a step profile placed on top, ideal for architectual outdoor lighting, typically giving off light from the sides, suitable to illuminate walkway including PCC work as required complete all as specified and directed.
M&L, in repairs, earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth strip of 25x4mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part I connected to earth test point using earth strip of 25x4mm as earth lead all as specified and testing on completion including provision of earth lead protected by 40 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work in any type of soil, PCC pit with RCC cover, char coal, salt, funnel etc complete. Note : Rate quoted by tenderers shall be deemed to include for following provisions;-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 M.[ii]. PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii]. Main earthing lead from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs, charcoal & salt as reqd.[v]. GI protection pipe of size 40 mm bore light grade 7.5m
S&F, in repair, PVC junction box, factory made, with one No SP MCB of 20 Amp rating, class-B connector fixed on pole with necessary clamps and bolts etc duly painted with two coats of aluminum paint over a coat of red oxide primer including connecting with street light cable including taking dowo old complete all as specified and directed.
S&F, in repairs, bracket made out of light grade, Galvanised steel tube, 40mm bore, 1.2 Mtr length, fixed to pole with necessary clamps made out of FI 25mm x 4mm with nuts & bolts including additional alteration to fixing of street light complete all as specified and directed.
M&L for horizontal boring by using trenchless technology under the road at least 60 cm below road top, in any type of soil suitable for insertion of 50mm bore CI/GI pipe complete all as specified and directed.
M&L for horizontal boring by using trenchless technology under the road at least 60 cm below road top, in any type of soil suitable for insertion of 100mm bore CI/GI pipe complete all as specified and directed.
Taking down existing panel and Supply, installation, commissoning and testing, LT Panel (415 Volts, 50 Hz , 3-phase, 4 wire supply), plinth mounted, factory made, outdoor type, weather and vermin proof (Protection Class IP-54) made out of 40mm x 40mm x 6mm angle iron frame and 3.00 mm thick MS Sheet CRCA sheet powder quoted with front and back hinged opening, rubber lining, locking arrangement, painted, externally and internally with two coats of synthetic enamel gray paint (First quality) over a coat of red oxide primer, grouting panel, through angle iron, 0.2 mtr in ground and 0.5 mtr over the ground including excavation & earth work in any type of soil and PCC (1:3:6) type C-2 using 40mm graded stone aggregate complete omprising of the followigs :- (a) Incoming supply:- (i) Aluminium bus bar chmber 250 amps rating of 04 strip - 01 No (ii) MCCB, Thermal magnetic setting, 4 pole, AC, 415 volts, 200 Amp rating, 25 KA rupturing capacity - 01 No (iii) Panel mounted multifunction meter suitable to operate on and incl CT in accuracy class 1.0, suitable 3 Phase CT network CT primary programmable up to 400 Amps, three line baklit display of phase to phase rating Phase to neutral voltage current active power KW, KVAR and KVA, PF Frequency. (iv) Indicating lamp Neon type for R-Y-B - 03 Set (b) Outgoing supply:- (i) MCCB, thermal and meganitic setting, TPN, AC, 415 Volts, 63 Amp rating, 16 KA rupturing capacity - 04 No Note : All MCCBs should be conneted with aluminium strip Bus Bar.
Taking down existing panel and Supply, installation, commissoning and testing, LT Panel (415 Volts, 50 Hz , 3-phase, 4 wire supply), plinth mounted, factory made, outdoor type, weather and vermin proof (Protection Class IP-54) made out of 40mm x 40mm x 6mm angle iron frame and 3.00 mm thick MS Sheet CRCA sheet powder quoted with front and back hinged opening, rubber lining, locking arrangement, painted, externally and internally with two coats of synthetic enamel gray paint (First quality) over a coat of red oxide primer, grouting panel, through angle iron, 0.2 mtr in ground and 0.5 mtr over the ground including excavation & earth work in any type of soil and PCC (1:3:6) type C-2 using 40mm graded stone aggregate complete omprising of the followigs :- (a) Incoming supply:- (i) Aluminium bus bar chmber 300 amps rating of 04 strip - 01 No (ii) MCCB, Thermal magnetic setting, 4 pole, AC, 415 volts, 250 Amp rating, 25 KA rupturing capacity - 01 No (iii) Panel mounted multifunction meter suitable to operate on and incl CT in accuracy class 1.0, suitable 3 Phase CT network CT primary programmable up to 400 Amps, three line baklit display of phase to phase rating Phase to neutral voltage current active power KW, KVAR and KVA, PF Frequency. (iv) Indicating lamp Neon type for R-Y-B - 03 Set (b) Outgoing supply:- (i) MCCB, thermal and meganitic setting, TPN, AC, 415 Volts, 63 Amp rating, 16 KA rupturing capacity - 02 No (ii) ON load Change over switch 3 Phase 200 Amp - 01 No. (iii) Digital Timer switch three phase 30Amp along with contactor for operation of 100 Nos street lights - 01. Note : All MCCBs should be conneted to Bus Bar.
Taking down existing panel and Supply, installation, commissoning and testing, LT Panel (415 Volts, 50 Hz , 3-phase, 4 wire supply), plinth mounted, factory made, outdoor type, weather and vermin proof (Protection Class IP-54) made out of 40mm x 40mm x 6mm angle iron frame and 3.00 mm thick MS Sheet CRCA sheet powder quoted with front and back hinged opening, rubber lining, locking arrangement, painted, externally and internally with two coats of synthetic enamel gray paint (First quality) over a coat of red oxide primer, grouting panel, through angle iron, 0.2 mtr in ground and 0.5 mtr over the ground including excavation & earth work in any type of soil and PCC (1:3:6) type C-2 using 40mm graded stone aggregate complete omprising of the followigs :- (a) Incoming supply:- (i) Aluminium bus bar chmber 400 amps rating of 04 strip - 01 No (ii) MCCB, Thermal magnetic seting, 4 pole, AC, 415 volts, 315 Amp rating, 35/36 KA rupturing capacity - 01 No (iii) Panel mounted multifunction meter suitable to operate on and incl CT in accuracy class 1.0, suitable 3 Phase CT network CT primary programmable up to 400 Amps, three line baklit display of phase to phase rating Phase to neutral voltage current active power KW, KVAR and KVA, PF Frequency. (iv) Indicating lamp Neon type for R-Y-B - 01 Set (b) Outgoing supply:- (i) MCCB, thermal and meganitic setting, TPN, AC, 415 Volts, 200 Amp rating, 25 KA rupturing capacity - 01 No (ii) MCCB, thermal and meganitic setting, TPN, AC, 415 Volts, 100 Amp rating, 25 KA rupturing capacity - 01 No (iii) MCCB, thermal and meganitic setting, TPN, AC, 415 Volts, 63 Amp rating, 25 KA rupturing capacity - 03 No Note : All MCCBs should be conneted with aluminium strip Bus Bar.
Taking down existing panel and Supply, installation, commissoning and testing, LT Panel (415 Volts, 50 Hz , 3-phase, 4 wire supply), plinth mounted, factory made, outdoor type, weather and vermin proof (Protection Class IP-54) made out of 40mm x 40mm x 6mm angle iron frame and 3.00 mm thick MS Sheet CRCA sheet powder quoted with front and back hinged opening, rubber lining, locking arrangement, painted, externally and internally with two coats of synthetic enamel gray paint (First quality) over a coat of red oxide primer, grouting panel, through angle iron, 0.2 mtr in ground and 0.5 mtr over the ground including excavation & earth work in any type of soil and PCC (1:3:6) type C-2 using 40mm graded stone aggregate complete omprising of the followigs :- (a) Incoming supply:- (i) Aluminium bus bar chmber 300 amps rating of 04 strip - 01 No (ii) MCCB, Thermal magnetic seting, 4 pole, AC, 415 volts, 250 Amp rating, 25 KA rupturing capacity - 01 No (iii) Panel mounted multifunction meter suitable to operate on and incl CT in accuracy class 1.0, suitable 3 Phase CT network CT primary programmable up to 400 Amps, three line baklit display of phase to phase rating Phase to neutral voltage current active power KW, KVAR and KVA, PF Frequency. (iv) Indicating lamp Neon type for R-Y-B - 03 Set (b) Outgoing supply:- (i) MCCB, thermal and meganitic setting, TPN, AC, 415 Volts, 63 Amp rating, 16 KA rupturing capacity - 02 No (ii) ON Loan Change over switch 3 Phase 200 Amp - 01 Note : All MCCBs should be conneted with aluminium strip Bus Bar.
Taking down old unserviceable ACSR conductor of any size incl cross arm and connected items complete all as specified and directed.
Taking out old GI Pipe and Supply and laying GI pipe 50mm dia light grade below road / fixed to along the poles / walls with necessary clamping, including encasing the cable into the pipe all as specified and directed.
Taking out old GI Pipe and Supply and laying GI pipe 100mm dia light grade below road / fixed to along the poles / walls with necessary clamping, including encasing the cable into the pipe all as specified and directed.
Shree Builders
Priya Construction co.
SNEH TRADERS
DMA PROJECTS
Ramdev and Sons
divyarsh entrprise
Navkar Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .