Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAccepted-AOC 5B FF NAND VIHAR AZAD NAGAR NEAR GODARA PETROL PUMP HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L1 | Accepted-AOC Due to lowest accepted | |
| 2 | L2₹7.4 L+₹58,370.50 (8.60%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹8.2 L+₹1.4 L (20.4%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹8.3 L+₹1.5 L (22.4%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹11.7 L+₹4.9 L (72.5%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
12 Aug 2022, 6:00 pmClosed
Garrison Egnineer Ludhiana
Garrison Engineer Military Engineer Services CG Complex Ludhiana-141001
REPAIR AND MAINT TO INTERNAL ELECTRIFICATION SYSTEM AND CONNECTED WORKS AT CG COMPLEX DORAHA AND PHILLAUR UNDER GE LUDHIANA
2022_MES_538520_1
GE/LDH-28/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
CG Complex Doraha Phillaur under GE Ludhiana
As per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE Ludhiana
₹30,000
Yes
2 Sept 2022
16 Jul 2022
13 Aug 2022
16 Jul 2022
12 Aug 2022
29 Jul 2022
16 Jul 2022 - 28 Jul 2022
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power, bell point ) complete, including fixture and fittings such as switches, bell push,ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials for taking credit and making good disturbed surfaces of walls, floors, etc
M&L for Point wiring concealed conduit type with 1.5 sqmm PVC insulated unsheathed and multi stranded copper conductor PVC conduit 20 mm bore having 2 mm wall thickness with all conduit accessories for one light /fan/buzzer/soket outlet point controlled by one switch including continuous 1.5 sqmm copper conductor, stranded (green colour as earth ,red as phase and black as neutral), PVC insulated unsheathed earth wire to common earth and connected to earth dolly to be terminated in and including suitable size module boxes alongwith modular cover plate for housing of module switches/sockets etc . . Note : Unit rates quoted by contractor shall be deemed to included for cutting chases in walls and making good in cement morter (1:3) and finishing the surface to match with exisiting surface with distemper and wall putty.
One ligth point controlled by one switch with cables 1.5 sqmm size
One celing/Exhaust fan point controlled by one switch with cables 1.5 sqmm size
One 3 pin socket outlet,5 amps,independent,with cables 1.5 sqmm size
One 3 pin socket outlet 5 amps on same board with other switches,with cables 1.5 sqmm size
One bell/buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sqmm size.
One light point controlled by 2 way switches,with cables 1.5 sqmm size.
All as per item No. 2 here in before but 2.50 Sqmm copper conductor wiring with 2.50 Sqmm copper conductor as earth continuity for 15/16 Amps socket outlet on independent board.
All as per item No. 2 here in before but 4 Sqmm copper conductor wiring wiht 2.5 Sqmm copper conductor as earth continuity for 15/16 Amps socket outlet on independent board.
M & L for point wiring complete with 1.5 Sqmm PVC insulated and unsheathed FRLS cable single core multi stranded copper conductor, 1100 volts grade drawn through and including PVC casing / capping including copper earth continuity wire of PVC insulated of size 1.50 Sqmm and connected to common earth dolly with all accessories (gang box for switch socket, ceiling rose box,holder box,tee ,bend etc ) complete as specified for : -
One ligth point controlled by one 6 Amp one way switch
One celing/Exhaust fan point controlled by one 5 Amps one-way switch and regulator.
One 5 pin 6Amps switch socket outlet point on independent board
One 5 pin 6Amps switch socket outlet point on same board
One call bell point controlled by one 5 Amps one-way switch.
All as per item No. 5 here in before but 2.50 Sqmm copper conductor wiring with 2.50 Sqmm copper conductor as earth continuity for 15/16 Amps socket out let on independent board.
S&F in replacment of module switch 1 way 6 A, 1 module complete all as specified & directed.
S&F in replacment of module switch bell push type 1 way 6 A, 1 module complete all as specified & directed.
S&F in replacment of module switch 1 way 16 A, 1 module complete all as specified & directed.
S&F in replacment of modular socket, 6 Amps, 2/3 pin combined 2 module complete all as specified
S&F in replacment of modular socket, 6/16 Amps, 2/3 pin combined 2 module complete all as specified
S&F in replacment of modular step fan regulator 2 module complete all as specified
S&F white cover plate with frame ,1 module.
S&F white cover plate with frame ,2 module.
S&F white cover plate with frame ,3 module.
S&F white cover plate with frame ,4 module.
S&F white cover plate with frame ,6 module.
S&F white cover plate with frame ,8 module.
S&F in replacement switch socket combination outlet , 2 in 1 ,multipurpose 5 pin, 5/15 Amps, flush type having five holes for fixing complete all as specified and directed.
S&F in replacement switch 5 Amp ,flush type, multipurpose all as specfied and directed.
S & F for socket outlet 5 pin 5 Amps flush type complete all as specified and directed by Engineer - in - Charge.
S&F in replacement bell push, AC, 230 volts, single pole all as specified
S&F in replacement electronic resistance step speed regulator, suitable for 1200 mm sweep ceiling fan up to 300 watt all as specified.
S&F in replacement bell Ding Dong, AC, 230 volts, single pole controlled by one bell push all as specified
S&F in replacement lamp holder PVC/ Polycarbonate type with cord grip cap, insulated body, threaded dome pattern, suitable for pendant fittings.
Supply and fixing in replacment of Ceiling rose, 3 phase/PVC/ polycarbonate, isolated body.
Supply and fix in replacment of LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up to ceiling rose with three core 1.5 Sqmm flexible copper conductor complete all as specified and directed.
S & F in replacement of existing light fitting with LED batten integrated channel 20 watt having input voltage AC90-300V, 50 Hz , 6500K ,polycarbonate housing with white acrylic cover tube light fitting wall mounted complete with rod, driver and all other accessories including connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector complete all as specified and directed. Make:-Havells Model No.LUMILINEBS20WLED865SPCWH or equivalent in polycab and C&S)
S & F in replacment of existing light fitting with Water tight bulk head LED 10 Watt light fitting,comprision of connector galvanised cast iron back plate,weather proof enamelled gallery ,glass well,and including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and directed.
S & F in replacment of existing light fitting with LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F for bldg security light fitting LED TYPE 35 watt optic lenses with all necessary acessories, Clear transparent acrylic cover, prewire suitable to operated on 230 volt 50 HZ AC & Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 32 mm bore “light grade” brackets 2 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed. (Make of light fitting - Havells /Surya /Polycab)
Supply and fix in replacment of Existing bulb to LED Bulb 9 watt ,retrofit pin type,B22 Base cap,lumen output 950lm,6500K colour temp, complete all as specified and directed.
Supply and fix in replacment of Existing bulb to LED Bulb 14 watt ,retrofit pin type,B22 Base cap,lumen output 700lm,6500K colour temp, complete all as specified and directed.
Supply and fixing for post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorativepost top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete. complete all as specified and directed.
S & F in repairs sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 2 ways, 240 Volts, ISI marked, 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed.
S & F in repairs sheet metal enclosure for double door DBs made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted VTP & N 4 ways, 415 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCCB and isolators etc including fixing in Wall with Cement mortar complete all as specified and directed.
S & F in repairs sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 8 ways, 240 Volts, ISI marked, 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed. (Make - Havells / Legrand / indoasian)
S & F in repairs sheet metal enclosure for double door BD made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 12 ways, 240 Volts, ISI marked, 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed .
S & F for isolator 63 Amps 415 V , 3 Phase 'C' series, 25KA , complete all as specified and directed.
S & F for isolator 40 Amps 415 V , 3 Phase 'C' series, 25KA , complete all as specified and directed.
M & L in replacment of existing AC Box having Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 A complete all as specified and directed.
Supply and fixing for amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN 32 A carrying capacity in the MCB DB complete with onnection testing and commissioning all as specified and as directed.
Supply and fixing for amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN 40 to 63 A current carrying capacity in the MCBDB complete with connection testing andcommissioning as all as specified and as directed.
Supply and fixing for 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning,complete all as specified and as directed.
M & L for sub main wiring with two run of 1.5 Sqmm (nominal cross sectional area ) of single core unsheathed PVC (FRLS) insulated cables 1100 Volts grade multi stranded copper conductor drawn through & including non metallic rigid PVC conduit of size 19/20 mm or higher dia with & including necessary conduit accessories concealed/surface only on roof & colomn) type including one run of 1.5 Sqmm stranded copper conductor PVC (FRLS) insulated cable as earth wire connected to common earth dolly complete all as specified & directed. Note:- Two run cable and one run of earth wire shall be measured as one unit.
M&L for wiring for circuit/submain wiring in PVC Conduit along with earth wire with 2x4Sqmm+1x2.5Sqmm as earth wire of FR PVC insulated copper conductor single core cable (ISI marked) including taking down old wiring, complete all as specified and directed. Note:- Two run cable and one run of earth wire shall be measured as one unit.
S & F in replacement of sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLS stranded copper conductor drawn in concealed PVC conduict dia 20mm “medium quality” conduit including 6.00 Sq mm (Nominal Area) copper cable as earth continuity conductor after chasing in wall and making good the disturbed surfaces and white wash or existing colour , necessary junction box and covers including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed . Note:- Two run cable and one run of earth wire will be measured as a one unit.
S & F for rigid non-metallic PVC conduit for segregarion of existing hanging wires ,medium grade 20 mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.
M&L for Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 03 of 2009 SSR Pt-I and testing on complete including earth work in any type of soil, PCC 1:2:4 type B-0 as in earth pit and cover 40mm thick reinforced with XPM (weight not less than 4.0Kg/Sqm) in proper shape,testing on completion, all as specified and directed. ((i) Testing shall be arranged by contractor without any extra cost).
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 2 core complete all as specified and directed. (Note :- earth work shall be measure seperately and paid as per respective shcedule item)
Excavation in trenches n. exc. 1.5 metre wide for foundations, laying cables and similar works n. exc. 1.5 m deep and getting out in soft/ loose soil complete all as specified & directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified & directed.
Removal of excavated surplus spoil to a distance n. exc. 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified & directed.
M & L for sand cushioning for under ground cable 23cm thick (one layer of 8cm thickness before laying the cable and other layer of 15cm thickness after laying the cable) all as specified and directed by Engineer-in-Charge. Note:- Thickness of only 18cm after punning shall be considered for payment.
M & L for brick protection with old size sub class 'B' bricks laid flat across the route of underground cable all as specified and directed.
TESLA ENGINEERS & BUILDERS
JAI DURGA CONSTRUCTION COMPANY
shri ram enterprises
R K ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .