Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L4₹37.1 L+₹7.6 L (25.5%)Accepted-AOC D1C 47A JANAK PURI NEW DELHI 110058 | NEW DELHI | DELHI | DELHI | 110058 | L4 | Accepted-AOC L1 Bidder amongst bonafide bidders | |
| 2 | L1₹29.9 LRejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L1 | Rejected-Finance NON BONAFIDE. QUOTED BELOW MINIMUM WAGES. | |
| 3 | L2₹31.0 L+₹1.0 L (3.41%)Rejected-Finance | L2 | Rejected-Finance NON BONAFIDE. QUOTED BELOW MINIMUM WAGES. | |
| 4 | L3₹34.4 L+₹4.5 L (15.0%)Rejected-Finance FLAT NO 151 BLOCK NO 1 DIAMOND SQUARE CGHS LTD PLOT NO 13A SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L3 | Rejected-Finance NON BONAFIDE. QUOTED BELOW MINIMUM WAGES. | |
| 5 | L5₹41.5 L+₹11.5 L (38.5%)Rejected-Finance 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | L5 | Rejected-Finance NON BONAFIDE. QUOTED BELOW MINIMUM WAGES. |
Tender Value
₹33.6 L
EMD Value
₹67,200
Closing Date
3 Oct 2020, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
OUTSOURCING OF SERVICES FOR LIFT OPERATORS AT P-25 AND P-28 BLOCK, DG SET FOR RAC MAIN BUILDING, RAC HOUSE AND RAC GUEST HOUSE, MRS SUBSTATION AT RAC MAIN BUILDING AT KWC AREA UNDER GE I RND DELHI
2020_MES_360037_1
GE/RND-37/DLI/2020-2021
Open Tender
Manpower Supply
Item Rate
330 days
DELHI
Class - D, Cat d(v)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹67,200
Yes
5 Jan 2021
10 Jul 2020
5 Oct 2020
10 Jul 2020
3 Oct 2020
21 Sept 2020
Amount
PART-1 - OUTSOURCING SERVICES Outsourcing services for electrically operated lift of capacity 13 passangers - 01 No and Goods Lift- 01 No (make:-Evaan Elevators Pvt Ltd), suitable for G+7 (Ground+7 floors) installed at P-25 Block to be operated in three shift per day (0600 hrs to 1400 hrs Ist Shift, 1400 hrs to 2200 hrs 2nd Shift, 2200 hrs to 0600 hrs 3rd Shift) in all working days including Sunday & Holidays by deploying one trained Operator cum Mechanic (skilled) per shift complete all as specified and as directed.
Outsourcing services for electrically operated lift of capacity 13 passangers - 02 Nos (make:-Evaan Elevators Pvt Ltd), suitable for G+7 (Ground+7 floors) installed at P-28 Block to be operated in three shift per day (0600 hrs to 1400 hrs Ist Shift, 1400 hrs to 2200 hrs 2nd Shift, 2200 hrs to 0600 hrs 3rd Shift)in all working days including Sunday & Holidays by deploying one trained Operator cum Mechanic (skilled) per shift complete all as specified and as directed.
Outsourcing services for electrically operated lift of capacity 08 passangers - 02 Nos,(Make:- Schindler India Pvt Ltd) suitable for G+7 (Ground+9 floors) installed at Nag Choudhary to be operated in three shift per day (0600 hrs to 1400 hrs Ist Shift, 1400 hrs to 2200 hrs 2nd Shift, 2200 hrs to 0600 hrs 3rd Shift) in all working days including Sunday & Holidays by deploying one trained Operator cum Mechanic (skilled) per shift complete all as specified and as directed.
Rate required to be quoted for executing the work as described in Ser item No 1.00 to 3.00 above
Workers wage per person as per existing rules
ESIC (Employees state insurance contribution) as mentioned in tender document
Bonus as mentioned in tender documents
Overhead & Profit on Ser No 4.01 to 4.03
LWC as mentioned in tender documents for ser No 4.01 to 4.04
GST as mentioned in tender documents ser No 4.01 to 4.04
Notes : Rate quoted by the contractor shall deemed to be included the following :- (i) Operator cum mechanic (skilled) shall be of Diploma/ITI passed with having training certificate in relevent trade not less than three year shall be employed for each shift.. (ii) It is an express condition of the contract that tenderers are required to quote their rates duly considered minimum applicable as per policy wages of the tradesmen intended in the tender, as in force on the end date of bid submission. It shall be deemed that quoted rates are based on minimum wages notified by the concerned authority for the station i.e Govt of India/State Govt/Union Teritory, whichever is higher including all statutory provisions such as EPF, GST, ESIC , Bonus, labour welfare cess (LWC) and contractor's overhead & profits etc as applicable. (iii) In case the rates quoted by tenderer are less than the notified minimum wages as on bid submission end date including all statutory provisions such as EPF, GST, ESIC, Bonus, labour welfare cess (LWC) and contractor's overhead & profits etc as applicable, his tender will be treated as non-bonafide and will not be considered for Acceptance. In such case, the lowest tender shall be determined amongst valid/bonafide bids only. (iv) The firm/contractor shall be solely and fully responsible to his reprsentative/personal for any accident/damage during maintenance/operation/health related liabilities/compensation, penelty etc on this account. (v) T&P required such as spanner set, wrench, screw driver set, testing lamp, drilling machine and multimeter, tong tester, megger etc as well as protective devices (shoes, helmet etc) shall be provided by the contractor at no extra cost. (vi) Contractor shall be responsible to maintain log books, duty roster attendance register and spare for repair/renewal of parts register, earth register, serviceability register of lifts and as directed by Engr-in-charge. (vii) Shift Operator (reliever) shall neither leave the installations without prior permission of JE/Engineer-in-Charge. Proper handing/taking over to the next operator will be made.
(viii) Ttwo pairs of uniform with name plate of operator and shoes shall be provided to each operator by the contractor. (ix) Cleaning of complete lift, machine room of lift, greasing, tightening of nuts , bolts will be carried out by the operator employed by the contractor. (x) First Aid box will be provided by contractor at each installation. (xi) Any increase in minimum wages of labour as fixed by the Govt of India/state Govt/ union Territory, whichever is higher shall be paid to the contractor in accordance with the provision made vide condition 63 of IAFW-2249. Increased wages including all other benefits in compliance of statutory provisions shall be paid to workers by the contractor. no other claim whatsoever shall be addmissible on this account and the bidders shall consider this aspect while quoting their rates. It must be noted that in compliance of the statutory provisions, the increased will be passed over to the workers. (xii) Any consumble item shall be issued by department free for fixing/filling. The contractor shall collect and transport the same from E/M store yard to the requisite installations within 24 Hours at his own cost and arrangement. Proper record for issue & receipt for this shall be maintained by the Engineer-in-Charge & contractor. (xiii) The Contractor shall not pay wages lower than the latest notified minimum wages in force to their workmen/ tradesmen including all other benefits in compliance of statutory provisions. Bidders shall consider this aspect while quoting their rates. (xiv) Duty roster for detailement of operators shall be approved by Engr-in-charge within first three days of every month and the same shall be kept on record and properly displayed at each installation. (xv) The contractor will arrange the earth tester, Megger & clamp meter for installation and will check all the earthings of lifts for its serviceability in presence of JE E/M, Engr-in-charge and test report shall be submitted to the office of AGE E/M duly signed by the contractor on commencement of work for record. (xvi) For any damage to the installations due to negligence of operator such as loose connections, improper routine check up/maintenance etc. the contractor shall be held fully responsible to replace the same damage at his own cost all as directed by Engr-in-charge. (xvii) Original certificates regarding qualifications of operators engaged in the work, police verification and identity proof shall be produced by the contractor to the Engineer-in-Charge for verification and approval.
PART-II : REPAIR/MAINT WORK M&L for disconnecting, dismantling and strip opening of the existing air handling unit of any description and in any position of capacity 50 TR for overhauling and servicing, including taking out existing shaft, blower drum, pulley and de-humidifier pump etc of air handling unit, checking thoroughly serviceability of the parts, and refixing the parts in positiion, reassembling, commissioning, fixing in position and testing of the air handling unit on full load for its smooth and trouble free operation complete all as specified.
M&L for disconnecting & dismantling of existing unserviceable cooling tower, FRP type 50 TR capacity of any description & in any positionincluding dimantling all old connected part/ filters, like motor, FRP casing basin, PVC filling, MS/GI pipe line, sluice valve, stop valve, steel structure frame etc. Servicing/ Overhauling, cleaning, oiling/ greasing and refixing of serviceable parts, reassembling the cooling towers and connected parts/ items fixed in existing position and testing at site on full load to the entire satisfaction of the Engineer-in-charge.
Supply & fix in repair of Aluminium alloy fan blades consisting of six nos of blades in one set suitable for 50 TR cooling tower all as specified and as directed.
M&L for overhauling of pump and motor including transporting to workshop and return after repairing/rewinding and rewinding of electric mortor with super enameled copper winding wire of existing gauge of capacity 7.5 HP capacity by opening up and cleaning of all parts such as impeller , rotor, stator, fan cover, greasing and reconnecting back and testing complete all as per specified and as directed.
M&L for overhauling of pump and motor including transporting to workshop and return after repairing/rewinding and rewinding of electric mortor with super enameled copper winding wire of existing gauge of capacity 10 HP capacity by opening up and cleaning of all parts such as impeller , rotor, stator, fan cover, greasing and reconnecting back and testing complete all as per specified and as directed.
Descalling and cleaning of 50 TR condenser water cooled by circulating the diluted chemical HCL by forced feed method not less than 6hrs duration by opening of the end covers of the condenser brushing the tubes thoroughly,re-fixing back the end cover of the condesers with 3mm thick rubber gasket and testing complete to maintaining desired discharge pressure and maintaining inlet water temperature 37.38˚ C and outlet water temperature 32.22˚C for water cooled condenser complete all as specified and as directed.
M&L for charging of Refrigerant R-407C for 50 TR AC Plant including testing after completion complete all as specified and directed.
M&L for charging of Refrigerant R-410A for VRF Unit including testing after completion complete all as specified and directed.
M&L for charging of Refrigerant R-22 for Cassette type AC including testing after completion complete all as specified and directed.
Supply & filling of compressor oil including taking down old oil and testing complete for Central AC plant of voltas model no. ACWCDS052DPMN2X2P all as specified and as directed.
M&L for Finding out leakage in the system by pressure holding with Nitrogen gas for 24 hours , leakage repair including brazing of 50 TR water cooled Chiller complete all as specified & directed.
M& L for rewinding of AHU motor of capacity 5HP with super enamelled copper winding wire of existing gauge including testing after repair complete all as directed.
S&F in repair of old unserviceable single phase preventer kit complete all as specified and directed.
M&L in repair of old unserviceable mild steel Butterfly Valve 150 mm dia CI body SS Disk EPDM seal & C-Ring PN1.6 pressure rating for chilled water with and including Nitrile rubber insulation of 50 mm thickness complete all as specified and directed.
M&L in repair of old unserviceable mild steel Butterfly Valve 100 mm dia CI body SS Disk EPDM seal & C-Ring PN1.6 pressure rating for chilled water with and including Nitrile rubber insulation of 50 mm thickness complete all as specified and directed.
S&F in repair of V belt of size A42 ISI marked complete all as specified and directed.
S&F in repair of V belt of size A43 ISI marked complete all as specified and directed.
S&F in repair of V belt of size A46 ISI marked complete all as specified and directed.
S&F in repair water pressure gauge suitable for water pressure 0-16/20 kg/sq cm complete all as soecified and as directed.
S&F in repair industrial type thermometer of range 0-50 degree centigrade for AC plant complete all as specified and as directed.
S&F in repair suction pressure gauge suitable for suction pressure 0-250 PSI for AC Plant complete all as specified and as directed.
S&F in repair suction pressure gauge suitable for suction pressure 0-500 PSI for AC Plant complete all as specified and as directed.
S&F in repair timer electronic type for central AC plant of capacity 50 TR complete all as specified and as directed.
S&F in repair single phase preventer relay suitable upto 20HP motor inbuilt star delta timer mode of operation, auto complete all as specified and as directed.
S&F in repair power contactor of MNX - 25 complete all as specified and as directed.
S&F in repair of LP switch for central AC plant of capacity 50 TR complete all as specified and as directed.
S&F in repair of HP switch for central AC plant of capacity 50 TR complete all as specified and as directed.
S&F in repair of refrigerant copper pipe 15mm bore with insulation complete all as specified and as directed.
S&F in repair of refrigerant copper pipe 12 mm bore with insulation complete all as specified and as directed.
M&L for Isolating/Disconnecting and dismantling of unserviceable compressor 8TR capacity from VRF type AC unit and supply and fixing with new hermatically sealed scroll compressor of 8 TR capacity including leakage and pressure tesing with Nitrogen gas for 24 hours and gas charging with R-22 refrigarent complete all as specified and directed
S&F in repair of PCB suitable for cassete type AC of capacity 4.1 TR capacity suitable for make-Haier.
supply and fixing in repair of thermostatic expansion valve for 8 HP capacity compressor complete all as specified and directed. Make - Alco/Copeland
M & L for Servicing of VRF inverter split type 3 phase AC of capacity 8 TR. of make-Bluestar, including oiling/greasing the blower motor, cleaning the evaporator condenser coils externally to remove the dust, replacement of defective thimbles etc and re-fixing the air conditioner at its original position complete all as specified and as directed
S&F MCCB 400Amps 4 Pole breaking capacity 35KA fixed type including taking down old burnt MCCB from LT panel of AC plant complete all as specified and as directed.
S&F MCCB 250Amps 4 Pole breaking capacity 35KA fixed type including taking down old burnt MCCB from LT panel of AC plant complete all as specified and as directed.
S&F MCCB 125 Amps 4 Pole breaking capacity 25KA fixed type including taking down old burnt MCCB from LT panel of AC plant complete all as specified and as directed.
S&F MCCB 100Amps 4 Pole breaking capacity 25KA fixed type including taking down old burnt MCCB from LT panel of AC plant complete all as specified and as directed.
Taking down of existing unserviceable micropressor magnum controller and M&L for installation of Microprocessor Magnum Controller alongwith Software, installation including thimbles control wire etc complete suitable for 50TR AC Plant of make-Voltas model No. ACWCDS052DPMN2X2P.
S&F in repair of old unserviceable filter of size 2'X2' with 50 mm thick metal viscous washable synthetic type air filter upto 10 micron from AHU of capacity 2160 to 3500 CFM complete, all as specified and as directed.
Supply, installation, testing and commissioning in repair auto air vent valve of 15 mm dia.
M&L for repair of hot water generator of capacity 30 KW in four banks complete with one slave bank controlled by semi conductor rectifier & other necessary controls, electrical panels etc. complete all as specified & directed.
S&F in repair including testing of chiller water flow valve with electric control and other works as required at site to make the system functional incl welding as required at site etc complete all as specified and as directed.
M&L for servicing of hot water generator upto 30KW 3 phase 415 Volts including replacement of old burnt strip heaters and testing complete.
M&L for Descaling of condensing coil of 50 TR capacity central air conditioning plant with cleaning agent by forced feed method to remove the unwanted dust formed over the cooling coil fins without disturbing the mounting of the coils and greasing to the AHU blower bearing and tightening of all fasteners etc including testing complete all as specified and as directed .
Supply and fix thermostatic expansion valve suitable for 50 TR capacity central air conditioning plant including cutting and brazing including taking down existing unserviceable thermostatic expansion valve complete all as specified and directed. Make: Sporlan/Indfos/Danfos.
M&L for Dismantling the compressor of 50 TR AC plant from installed position after disconnecting the suction and discharge refrigerant line, open the compressor for carrying out the repairs of unserviceable parts, setting of valve reeds, valve plates, bearings, loading and unloading mechanism, pistons with rings, oil seals, oil pumps etc after carrying out necessary lathe work for grinding and polishing the worn out seatings/ housing of the compressor body and assembling with essential minor parts i.e. split pins, nuts, bolts, washers, rubber rings etc and fixing in its position including testing for proper functioning complete all as specified and directed
Material and labour for pumping down the refrigerant for re use from the gas line to the chillar unit of 50 TR AC plant, removing the existing insulation at the shell and tube chiller and carefully dismantling the refrigerant pipe lines, chilled water circulation pipe lines with valves on both inlet and outlet side. Cut open the chiller in a dust free environment with proper tools and equipments and replacement of the damaged existing copper gas pipe line with new annealed copper pipe line of the existing diameter with minimum 0.5mm thick fixing in original position including necessary brazing/ welding and fixing for smooth functioning. Re-assembling the chiller unit with proper Air tight sealed for leak proof by ensuring filling with Nitrogen gas for 24 hours pressure test and covered the complete chiller with nitrate insulation with minimum 19mm thick before connecting, testing and commissioning complete all as specified & directed.
M & L for Servicing of the Cassete type AC 4 ton capacity of any make, including oiling/greasing the blower motor, cleaning the evaporator condenser coils externally to remove the dust, replacement of defective thimbles etc and re-fixing the air conditioner at its original position complete all as specified and as directed
S&F in repair Condensing coil suitable for cassete type AC of capacity 4.1 TR complete all as specified and directed.
S & F in repair cooling coil suitable for cassete type AC of capacity 4.1 TR complete all as specified and directed.
S&F in repair Indoor unit for cassette type AC of capacity 4.1 TR complete all as specified and directed.
S&F In repair outdoor unit for cassette type AC of capacity 4.1 TR except compressor complete all as specified and directed.
S&F in repair compressor for 4.1 TR cassette type outdoor unit complete all as specified and directed.
S&F in repair Interconnecting refrigerant Copper pipe of size 15.9mm dia with closed cell elastometic nitrile rubber tubuler insulation between each set of indoor & outdoor units complete all as specified and as directed.
S&F in repair Interconnecting refrigerant Copper pipe of size 12.7mm dia with closed cell elastometic nitrile rubber tubuler insulation of thickness 20 mm between each set of indoor & outdoor units complete all as specified and as directed.
S&F in repair Interconnecting refrigerant Copper pipe of size 9.5mm dia with closed cell elastometic nitrile rubber tubuler insulation between each set of indoor & outdoor units complete all as specified and as directed.
S&F in repair Interconnecting refrigerant Copper pipe of size 6.4mm dia with closed cell elastometic nitrile rubber tubuler insulation between each set of indoor & outdoor units complete all as specified and as directed.
M&L for sub main wiring surface/recessed as required with two single core 6 sqmm PVC insulated and unsheathed FRLSH copper conductor, multistranded 1100 volts grade cable through and including non metalic rigid PVC conduit of size 25 mm dia including 6 sqmm FRLSH copper conductor multistranded PVC insulated and unsheathed wire as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing U/S sub main wiring and making good the disturbed surface to match with the existing all as specified and directed.
S&F in repair of GI piping work 100 mm dia of inlet/outlet of 6 meter length including plumbing work and Welding work as per existing complete in AC plant Cooling tower all as specified and as directed.
Supply & Fix in repair of ARD Battery for lifts 12 Volts 7 AH all as specified and directed. Make-Exide/Amaron/Mictrotex
Supply & Fix in repair of lift cabin light fittings 3Watt LED recess type down light all as specified and directed
Supply & Fix in repair of stainless Steel wire rope 13 MM dia for lifts all as specified and directed
Supply and fix in repair of cabin fan 150 MM dia metalic suitable for lift complete all as specified and as directed
Supply and fix in repair of lift door sensor complete all as specified and as directed
S&F in repair of control wiring for lift panel with 2.5 sqmm multistranded FRLSH copper cable complete all as specified and as directed.
Supply and fix in repair of push button with indicator complete all as specified and as directed
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron strip of 25x4 mm by means of Copper nuts, bolts and washers. Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a) GI strip of size 25mm x 4mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required 25x4 mm galvanised iron strip including taking down old unserviceable complete all as specified and directed
Choice india
BRIJ MOHAN LAL AND CO.
Pradeep Bros
Vishal Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .