| Sl No | Description | Qty | Unit | Ajay L1 | M/S sharma electrical and contractor L2 |
|---|---|---|---|---|---|
| 1.00 | Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. (Wires of Havells/KEI/ Plaza/Polycab and accessories of Anchor Penta make) Group C. | 99 | Each | 875 ₹86,625 Lowest | 885 ₹87,615 |
| 2.00 | Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit, with 2-way modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. (Wires of Havells/KEI/Plaza/Polycab and accessories of Anchor Penta make) Group C. | 1 | Each | 910 ₹910 Lowest | 910 ₹910 Lowest |
| 3.00 | Wiring for circuit / sub-main with 4x16 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No.16 Sq.mm. (4x16+2x16) HRFRLS/PVC insulated single core copper conductor cable for earthing as required. (Wires of Havells/KEI/ Plaza/Polycab and PVC conduit D-plast/ Anchor/ Polycab/Precision make) | 18 | Per metre | 1,075 ₹19,350 Lowest | 1,130 ₹20,340 |
| 4.00 | Wiring for circuit / sub-main with 3x25+1x16 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No.16 Sq.mm. (3x25+3x16) HRFRLS/PVC insulated single core copper conductor cable for earthing as required. (Wires of Havells/KEI/ Plaza/Polycab and PVC conduit D-plast/ Anchor/ Polycab/Precision make) | 9 | Per metre | 1,450 ₹13,050 Lowest | 1,600 ₹14,400 |
| 5.00Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required. (Wires of Havells/KEI/ Plaza/Polycab make) | |||||
| 5.01 | 3x1.5 Sq. mm. | 82 | Per metre | 85 ₹6,970 Lowest | 95 ₹7,790 |
| 5.02 | 5x1.5 Sq. mm. | 47 | Per metre | 135 ₹6,345 Lowest | 160 ₹7,520 |
| 5.03 | 3x2.5 Sq. mm. | 182 | Per metre | 125 ₹22,750 Lowest | 140 ₹25,480 |
| 5.04 | 5x2.5 Sq. mm. | 87 | Per metre | 190 ₹16,530 Lowest | 230 ₹20,010 |
| 5.05 | 3x4.0 Sq. mm. | 210 | Per metre | 165 ₹34,650 Lowest | 170 ₹35,700 |
Tender Value
₹4.7 L
EMD Value
₹9,420
Closing Date
24 Mar 2026, 5:00 pmClosed
Executive Engineer (D)
Executive Engineer (D) CSKHPKV Palampur
Construction of Labs and Examination hall for under graduate students COA, CSKHPKV, Palampur(SH Providing and fixing of Electrical Installation in fourth floor)
2026_HPKV_131658_1
EE CSKHPKV NIT No. 8998-9016 dated 09/03/2026
Open Tender
Construction Works
Item Rate
CSKHPKV Palampur
Please refer Tender documents.
7 documents required · 7 mandatory
₹350
EE (D) CSKHPKV,Palampur
₹9,420
31 Mar 2026
18 Mar 2026
25 Mar 2026
18 Mar 2026
24 Mar 2026
18 Mar 2026
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. (Wires of Havells/KEI/ Plaza/Polycab and accessories of Anchor Penta make) Group C.
Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit, with 2-way modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. (Wires of Havells/KEI/Plaza/Polycab and accessories of Anchor Penta make) Group C.
Wiring for circuit / sub-main with 4x16 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No.16 Sq.mm. (4x16+2x16) HRFRLS/PVC insulated single core copper conductor cable for earthing as required. (Wires of Havells/KEI/ Plaza/Polycab and PVC conduit D-plast/ Anchor/ Polycab/Precision make)
Wiring for circuit / sub-main with 3x25+1x16 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No.16 Sq.mm. (3x25+3x16) HRFRLS/PVC insulated single core copper conductor cable for earthing as required. (Wires of Havells/KEI/ Plaza/Polycab and PVC conduit D-plast/ Anchor/ Polycab/Precision make)
Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required. (Wires of Havells/KEI/ Plaza/Polycab make)
3x1.5 Sq. mm.
5x1.5 Sq. mm.
3x2.5 Sq. mm.
5x2.5 Sq. mm.
3x4.0 Sq. mm.
5x4.0 Sq. mm.
3x6 Sq. mm.
3x10 Sq. mm.
5x10 Sq.mm.
Supplying and drawing following pair of Fire Retardant, PVC insulated 0.5 sq.mm. (FR-Flexible) copper conductor, flat, unarmoured, telephone cable in existing surface / recessed, steel / PVC conduit as required. (Wires of Havells/KEI/ Plaza/Polycab make) 2 Pair
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:- (D-plast/Anchor/Polycab/ Precision make)
25 mm. dia
32 mm. dia
Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required. (Anchor Penta make) Telephone socket outlet, Modular.
Supplying and fixing stepped type Modular fan regulator on the existing modular box including making connections etc. as required. (Anchor Penta make)
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required. (Anchor Penta make)
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required. (Anchor Penta make)
Supplying and fixing ceiling rose on the existing junction box / wooden block including connections etc. as required. (Anchor make)
Supplying and fixing bakelite batten/angle holder including connections etc. as required:- (Anchor make)
Supplying and fixing copper strip bus-bars suitable for 100 Amp. 415 volts capacity 4 No. each of cross-sectional area (25.4mmx3.17mm),in the existing enclosure with all accessories including connections etc. as required:-
Supplying and fixing copper strip bus-bars suitable for 200 Amp. 415 volts capacity 4 No. each of cross-sectional area (25.4mmx4.75mm),in the existing enclosure with all accessories including connections etc. as required:-
Providing and fixing following rating and breaking capacity MCCB in the existing cubical panel board including drilling holes in the cubicle panel, making connections, etc. as required. (Havells/Lauritz Knudsen/Indo Asian make) 125 Amp. -16 KA
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- (Havells/Lauritz Knudsen/Indo Asian make) Single pole. Cat-A.
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- (Havells/Lauritz Knudsen/Indo Asian make) Double pole. Cat-A.
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Havells/Lauritz Knudsen/Indo Asian make) 63 Amps. Cat-A.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:- (Havells/Lauritz Knudsen/Indo Asian make)
Double door-8 way
Double door-12 way
Double door-16 way
Providing and fixing M.V.danger notice plate of 200 mm x 150 mm made of mild steel at least 2 mm thick, and vitreous enameled white on both sides and with inscription in signal red color on front side as required.
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:- (Havells/KEI/Polycab/Plaza make) Armoured cable 35 sq. mm (3.5 core)
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required:- (Havells/crompton make) Ceiling Fan 1200 mm sweep, Category-A
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- (Havells/crompton/Bajaj make) Exhaust Fan, Light duty, (Domestic) 300 mm sweep
Providing and fixing Decorative ultra slim polycarbonate LED tube lighting fixture with high lumen output,energy efficient ready to use pack complete with all accessories, connections, testing and commissioning etc. as required. (Havells make) 30 watt-LED (Havells/crompton/orient make) Clear.
Providing and fixing following type of recess mounting slim LED luminaire which provides soft-light and glare free round/ square shaped recessed mounted panel in a light weight plastic body complete with all accessories, connections, testing and commissioning etc. as required. 20 watt-LED (Havells/crompton/orient/Clear make).
Providing and fixing following type of Recess mounting LED luminaire 600mm x600mm panel with high performance LEDs, suitable for mounting with Armstrong/Grid ceiling complete with all accessories, connections, testing and commissioning etc. as required.- 2X2 PANEL 36 W 6500 K (Havells LHEBAEP7IW1W036/Clear or equivalent make).
Supplying and drawing electrolytic grade solid annealed bare copper conductor, 4 Pair unshielded twisted pair (UTP) CAT 6 Industrial cable with PVC Sheath for LAN Network in existing surface / recessed, Steel/PVC conduit as required. (D-link or equivalent make)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
BOQ_194689.xls
BOQ • 0.29 MB
sbd.pdf
Tender Documents • 20.61 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .