Repair
Maintenance
and Installation of Plant Systems/Equipments (Version 2) - ICGS Vishwast; E-233 01 in no 40 TPH submersible pump not developing sufficient pressure Same to be overhauled and proved for satisfactory operation; Service Provider
and Installation of Plant/Systems/Equipments (Version 2) - ICGS Vishwast; E-285 Heavy sea water leakage observed from aft fire and sprinkler pump Suspect mechanical seal worn out Mechanical seal to be renewed Post Defect rectifi..
and Installation of Plant/Systems/Equipments (Version 2) - ICGS Vishwast; E-290 Aft AC condenser pump discharge valve in Fin Compartment not holding Suspect spindle threads worn out Valve to be overhauled and proved for satisfa..
and Installation of Plant Systems/Equipments (Version 2) - ICGS Vishwast; E-296 Fwd fire and sprinkler pump is tripping due to activation of OLR and also drawing excessive current Suspect bearings worn out and reduction of clear..
and Installation of Plant/Systems/Equipments (Version 2) - ICGS Vishwast; E-298 Leakage observed from fresh water pipeline on boat deck view pipeline ruptured and uprooting non holding of one no cock valve Defective pipeline and..
9433053
GEM/2026/B/7632933
Two Packet Bid
Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS Vishwast; E-2
South Andamans, Andaman And Nicobar Islands
Item wise evaluation
SERVICE
3 documents required · 3 mandatory
1 yrs
₹1 L
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Repair | - | - | - |
| Maintenance | - | - | - |
| and Installation of Plant Systems/Equipments (Version 2) - ICGS Vishwast; E-233 01 in no 40 TPH submersible pump not developing sufficient pressure Same to be overhauled and proved for satisfactory operation; Service Provider | - | - | - |
| and Installation of Plant/Systems/Equipments (Version 2) - ICGS Vishwast; E-285 Heavy sea water leakage observed from aft fire and sprinkler pump Suspect mechanical seal worn out Mechanical seal to be renewed Post Defect rectifi.. | - | - | - |
| and Installation of Plant/Systems/Equipments (Version 2) - ICGS Vishwast; E-290 Aft AC condenser pump discharge valve in Fin Compartment not holding Suspect spindle threads worn out Valve to be overhauled and proved for satisfa.. | - | - | - |
| and Installation of Plant Systems/Equipments (Version 2) - ICGS Vishwast; E-296 Fwd fire and sprinkler pump is tripping due to activation of OLR and also drawing excessive current Suspect bearings worn out and reduction of clear.. | - | - | - |
| and Installation of Plant/Systems/Equipments (Version 2) - ICGS Vishwast; E-298 Leakage observed from fresh water pipeline on boat deck view pipeline ruptured and uprooting non holding of one no cock valve Defective pipeline and.. | - | - | - |
Exempted
Yes
19 Jun 2026
19 Jun 2026
29 Jun 2026
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_9433053.pdf
GEM_BID • 0.13 MB
1780752302.pdf
GEM_OTHER • 0.13 MB
1781797232.pdf
GEM_OTHER • 0.41 MB
gtc.pdf
GEM_OTHER • 0.71 MB
Download all tender documents and submit your bid