Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹14,026
Closing Date
4 Dec 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Executive Engineer
WS Subdivision,Kalamassey
DEPOSIT Eloor Municipality Deposit work Rearranging water pipeline near Labour Quarters of ward no 14 Eloor Municipality and allied works Pipeline Work
2024_KWA_710603_1
WRD/KWA-CE(CR)/TR/21202/2024
Open Tender
Civil Works - Water Works
Item Rate
120 days
Kalamassery
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,240
₹14,026
6 Dec 2024
28 Nov 2024
6 Dec 2024
28 Nov 2024
4 Dec 2024
28 Nov 2024
Amount
working charges
15.59:Dismantling of flexible pavement ( bituminous courses ) by mechanical means and disposal of dismantled material up to a lead of 1 kilo metre, as per direction of Engineer-in-charge.
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.9.9:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 110 mm nominal outside diameter pipes.
100.9.6:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 63 mm nominal outside diameter pipes.
100.9.11:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 160 mm nominal outside diameter pipes.
50.18.9.22.10:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap
50.18.9.20.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Bend
50.18.9.20.8:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia End cap
OD110114/2024-2025:Changing water connection from newly laid 160/110mm pvc using pvc saddle ,20mm - MTA, pvc bend, coulper 20mm pvc pipe etc including cost and conveyance of all materials and labour charges etc complete.
OD110113/2024-2025:Interconnection of existing 160mm PVC pipe with 110 mm pvc using 160x160x110mm Reducing Tee under the culvert including cost and conveyance of all materials and l;abour charges etc complete.
OD110116/2024-2025:Supplying & fixing MS "L" clamp for using supporting pipe including cost and conveyance of all materials, hire for tools and labour charges etc. complete. as per direction of Engineer in charge.
OD110115/2024-2025:interconnection from 110mm pvc to 40/50/63/75/90 mm pvc line using 110mm PVC saddle , 20mm fta ,coupling elbow etc
OD110119/2024-2025:Interconnection of existing 150mm AC pipe with 160 mm pvc using 150mm CID joint,160mm pvc coupling 160mm bend, including tar cutting earthwork excavation labour etc all
OD110123/2024-2025:For repairing works at kuttikkattukara jn -providing heavy machinery for handling big slab,other unforsceen items for the tapping and line repairing etc all as per the direction from the dept officials.
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
16.78.1:Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30
100.98.1008:Engaging Coolie.
100.98.1009:Engaging Fitter ( grade 1).
4.1.2:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:1/2:3 (cement : 11/2 coarse sand : 3 graded stone aggregate 20 mm nominal size)
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
OD133359/2024-2025:Conveyance charges loading and unloading charges for bringing the pipes from the section store to the work site at IAC road
ANTONY K G (BID ID -2001356)
MUKUNDA KUMAR (BID ID -1998501)
Bidder Name
ANTONY K G
MUKUNDA KUMAR
ABDUL SAMAD K B
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .