Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.4 LAccepted-AOC BALTIKURI INDUSTRIAL ESTATE PLOT NO A 01 DASNAGAR HOWRAH 711113 | HOWRAH | WEST BENGAL | 711113 | ₹28.4 L | L1 | Accepted-AOC L1 |
| 2 | L2₹30.6 LRejected-Finance | ₹30.6 L | L2 | Rejected-Finance L2 |
| 3 | L3₹32.2 LRejected-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | ₹32.2 L | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹64,132
Closing Date
10 Oct 2025, 10:00 amClosed
Room No. 108, Purta Bhawan, Salt Lake
Room No. 108, Purta Bhawan, Salt Lake
Construction of vertical extension (4th and 5th floor) of Institute Block at the West Bengal National University of Juridical Sciences, Salt Lake, Kolkata - 700 106 -- SITC of Air Conditioning System at Cafeteria
2025_WBPWD_897592_1
WBPWD/EE/BED/e-NIQ-79/2025-26
Open Tender
ELECTRICAL WORKS ORG
45 days
Juridical Sciences
Please refer Tender documents.
5 documents required · 5 mandatory
₹64,132
Room No. 108, Purta Bhawan, Salt Lake
30 Dec 2025
2 Sept 2025
13 Oct 2025
3 Sept 2025
10 Oct 2025
9 Sept 2025
8 Sept 2025
Amount
Supply of 16.5 TR to 17 TR capacity, 380-415 V, 50 Hz, 3 Phase, 4 Wires, Floor Standing Ductable Type Package Air Conditioner of rated cooling capacity minm 58 kW to 59.5 kW, Air-flow Rate 5700 - 6000 CFM, Noise Level <65 dBA. Outdoor:- Hermetically sealed scroll type Compressor, [motor out put 8.5 + 8.5 of design of OEM], Refrigerant - R410A / R407c, (Make: Daikin Model:[indoor FVPGR 20NY1 & Outdoor RUR20NY1] /MITSUBISHI Electric/Voltas/Bluestar)
Installation Testing Commissioning of above TR capacity said capacity machine.
SITC incl. vacuumization and Nitrogen of testing of following nominal size of soft/hard drawn Cu. refrigerant piping for Pacackage AC system, complete with fitting, with adjustable ring type hanger supports, jointing/brazing incl. accessories, Nitrile Rubber ' Class-O tubular insulation with closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and liquid lines, all accessories as per specification etc. as required. (Make- Ryoku/Rajco/Nippon) a) 15.9 dia Cu. Pipes incl. 19 mm thick insulation. (Liquid Line )
b) 34.9 dia Cu. Pipes incl. 19 mm thick insulation. (Gas Line)
Supply & Charging Refrigerant - 410 A / R407c
CABLING WORKS: S & F 1.1 KV grade, PVC insulated & unsheathed Control Cabling FRLS from Condensing Unit to Control Panel (make - Polycab / RR/Finolex/KEI/Gloster) a) 4 Core 10 sq. mm. Copper flexible Cable (from starter to ODU)
b) 4 Core 2.5 Sqmm Copper flexible Cable (from ODU to indoor connection)
Laying dedicated cable for earthing only through prelaid UPVC pipe from Supply System to ODU:- 2x 4.0 sqmm Copper flexible Cable for earthing. (Make:Finolex/KEI/Polycab)
Fabrication , supply, Installation , testing & commissioning of following GSS sheet conforming to IS:737 – 1955(Sail/TATA or as per choice of EIC) rectangular/round duct complete with neoprene rubber gaskets, elbows, splitter supports, flanges, turning vanes for supply air / return air duct erected with supporting rods, fustners, nuts etc. a. 0.8mm/22 SWG Ducting (Plenum Chamber)
b. 0.63mm/24 SWG Ducting (Supply duct)
Supply, installation, testing and commissioning of Aluminium powder coated supply air diffusers/grilles with volume control damper.Make - Premire /Systemair / Air Enterprise / Caryaire /Airmaster
Supply & Fixing of Aluminium powder coated return grilles without volume control damper. [Make - Premire /Systemair / Air Enterprise / Caryaire / Airmaster]
Supply, Installation, Testing and Commissioning of powder coated extruded aluminium louvers with synthetic removable type filter, bird screen & and volume control damper for fresh air intake.
Supply and fixing of Opposed blade GI Duct damper.Make - Premire /Systemair / Air Enterprise / Caryaire / Airmaster
Supply, Fixing & Testing of open cell nitrile rubber acoustic insulation, with density 32-40kg/cum. and having anti fungal & anti bacterial properties as per DIN EN ISO 846, MATHODA&C. The insulation should have been tested for air erosion at air velocity of 10000 fpm.(K-Flex / Amracell / Supreme)
Supplying and fixing of 13 mm thickness duly laminated aluminium foil of mat fininshed closed cell Nitrile rubber (class ''O'') insulation Anti Microbial Coating on duct after applying two coats of cold setting adhesive (The joints shall sealed with 50mm wide and 3 mm thick self afhesive nitrile rubber tape insulaton complete as per specifications and as required. for Duct (K-Flex / Amracell / Supreme/K Flex)
Fabrication of Support of Supply and return air duct by 40 x 40 x 5 angle iron frame incuding fixing of same and mending all the damages as per direction of EIC.
Supply and fixing flexible double canvass connection for AHU[IDU] and Plenum duct.
Installation of ODU on Roof top with making concrete Base foundation and VI Pad as per direction of EIC
Supply, fittings and fixing in position suspended type boxing for return and supply air arrangement incl. false ceiling for boxing of IDU with frame work of Aluminium hollow section of size 50x25 (2.0 mm thickness) combined with aluminium corner of size (38 mm x 25mm) suspended by aluminium hollow tube section of size 38mm x 25mm as suitable with ACP (Thickness- 3.0 mm) with another accessories incl. all incidental charges etc. as per direction of EIC.
Supply & laying drain Water piping work out of UPVC/ HDPE hard pipes(60 schedule) (Make HB / Supreme / Oriplast) incl. fitting , accessories bends, elbows, tees, flanges, tapings, etc. insulated with 9mm. Thick nitrile rubber tube insulation. 32 mm. Dia
Supplying,fabrication & fixing 3Nos. M.S u-channel of 6 mm thick of size (75mm x40mm x 40mm) of 1m. Lengthfor making platform for installation of outdoor unit of 15 TR ductable out door unit incl. drilling 2nos. Holes in each channel including cutting holes into the wall & grouting the same with Cement concrete ( 1:1 1/2 :3) etc. fabricated with horizental angle of 25mm X 25mm x 6mm including supporting angle 50mm X 50mm X 6mm in each platform in outer edge, for transmitting the load centrally through 2Nos. (50mm x 50mm x 6mm) Angle inserted into the exiting wall. The entire platform should be baricated & safe for ODU maintaince.
Note:- Rate should be quoted inclusive of all taxes and duties including GST.
REFRIGERATION AND AIRCONDITIONING CORPORATION (BID ID -6935606)
Lyric International (BID ID -6920958)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid