Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance U M 10 POLOVICTORY CINEMA COMPLEX STATION ROAD JAIPUR 302006 | JAIPUR | RAJASTHAN | 302006 | Admitted-Finance |
| 2 | Admitted-Finance B 4 25 DEVANSH ENCLAVE VAISHALI NAGAR CHITRAKOOT SCHEME JAIPUR RAJASTHAN 302021 VAISHALI NAGAR VAISHALI NAGAR | JAIPUR | RAJASTHAN | 302021 | Admitted-Finance |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
1 Apr 2022, 5:00 pmClosed
Medical Superintendent, SMS Hospital, Jaipur
SMS Hospital, Jaipur
Rate Contract for Maintenance and repair services (CAMC) of Split an window type air conditioners for two year at SMS Hospital, jaipur
2022_SMSMC_263614_1
06_10.03.2022
Open Tender
Miscellaneous Services
Item Wise
730 days
SMS Hospital
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Medical Superintendent, SMS Hospital
₹64,000
Yes
SMS Hospital, Jaipur
13 Apr 2022
14 Mar 2022
2 Apr 2022
15 Mar 2022
1 Apr 2022
26 Mar 2022
21 Mar 2022
All in all comprehensive maintenance of various type air conditioners after defect liability period of equipment including repair / replacement of compressor, condensing / cooling coil, refrigerant piping, fan motor, remote, charging of refrigerant when ever required and periodical servicing as per OEM’s recommendations to meet out the efficient performance of the equipment.
1.0/1.5/2.0 Tr window type air conditioner
1.5/1.8/2.0 Tr inverter / Non inverter split type air conditioner
All in all general servicing and cleaning of various type air conditioners during defect liability period of equipment including repair / replacement of compressor, condensing / cooling coil, refrigerant piping, fan motor, remote, charging of refrigerant when ever required and periodical servicing as per OEM’s recommendations to meet out the efficient performance of the equipment.`
1.0/1.5/2.0 Tr window type air conditioner
1.5/1.8/2.0 Tr inverter / Non inverter split type air conditioner
Shifting of existing air conditioners window type of various make capacity including drain pipe of air conditioner as required including making connection testing etc. as required
Shifting of exsting air conditioners split type of various make & capacity including copper pipe, drain pipe and electrical wire and making hole for fixing of air conditioneras required including making connection testing etc as required
SITC of interconnecting refrigerant pipe work with closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification including chase cutting, supports ets, as required
S & F of rigid CPVC (20mm) drain piping of 6 Kg/ cm2 with 6mm thick nitrile rubbe insulation
S & F of FR PVC insulated & sheathed 3 core flexible copper conductor ISI marked (IS:694) of 1.1 KV grade of following rating : 4.0 Sq. mm
Supply & fixing MS powder coated stand suitable for 1.0/1.5/2.0 Tr outdoor type of split AC
Supplying and charging of fresh refrigerant and testing of performance of air conditioners / fridge / water cooler of following capacity including.
1.5 Tr window / split A.C.
2.0 Tr window / split A.C.
Replacement of defective compressor by company repaired compressor of following gadget including testing etc. as required (carrier / kirlosker / techumshe/ shriram/voltas)
SDG POWER EQUIPMENTS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .