Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹2,000
Closing Date
9 Nov 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DGM(PandP)UC
DGM(PandP)UC PD Administrative building FACT,Udyogamandal
RE-ELECTRIFICATION OF S - 2 QUARTER IN FACT TOWNSHIP UDYOGAMANDAL-2022
2022_FACT_717244_1
03017/2022-23/E26244
Open Tender
Miscellaneous Works
Item Rate
60 days
FACT, Udyogamandal
Please refer Tender documents.
3 documents required · 3 mandatory
₹25
Yes
FACT
₹2,000
Yes
10 Nov 2022
11 Oct 2022
10 Nov 2022
11 Oct 2022
9 Nov 2022
11 Oct 2022
RE-ELECTRIFICATION OF S - 2 QUARTER IN FACT TOWNSHIP UDYOGAMANDAL-2022
Supply, erection, termination and commisioning of double door 20 way, 3Ph, 415 Volts MCB Lighting DB having the following: 1) 63A 4 pole isolator - 1 No. 2) 63 A 4 pole RCCB with sensitivity of 30 mA -1 No 3) 20 A SP MCB -4 Nos 4) 16 A SP MCB - 4 Nos 5) 10A SP MCB - 4 Nos LDB shall be mounted on suitable frame fabricated with ISA 50x50x6, epoxy painted and fixed. Supply of all required items and consumables are in the contractor's scope and the existing incomer cable 4 x 25/35 sq.mm PVC-A-PVC shall be made use of.
Open Pipe Point wiring with individual control for light / fan/ bell/ 6A modular plug sockets separatly mounted for TV points, modular switches, using flexible copper cable of 1.5 sq.mm for control and 2.5 sq.mm for neutral connection through 20mm PVC conduit(ivory colour) using metal saddles with spacing not exceeding 50 cm, as per relevant drawings or instructions from FACT engineer. The wiring shall be along beam/wall / column / ceiling, preparation and fixing of concealed modular switch boards, switches, cover plates,dummy plates etc, fixing ceiling roses on suitable junction boxes, modular Step type regulators for fans, drawing earth wires of 1.0 sq.mm flexible copper cable of green colour pvc for metal body earthing , connecting, testing and commissioning. For a point wring, pipe length greater than 10 metres shall be considered as one and a half point and 6A plug points shall be considered as half point wiring. All the materials required for wiring such as, copper flexible cable, Metalic Modular switch boards, switches cover plate, dummy plates, PVC box for fixing ceiling rose, PVC Junction boxes(2/3/4 way),Step type regulators etc. shall be in the scope of contractor.
Open pvc condiut wiring with individual control for 16A power sockets. All the materials required for wiring like modular switch boards, switches, cover plates,dummy plates,Junction boxes etc, 2.5 sq.mm flexible copper wires for P&N,drawing earth wires of 1.5sq.mm flexible copper cable of green colour pvc for body earthing of metal clad items, connecting, testing and commissioning. For a point wring, if pipe length greater than 10 metres shall be considered as one and a half point. ( If additional power sockets required in same switch board that shall be considered as half point.)
Supply, fixing and servicing of 20W LED tube fittings/calling bells/18w LED round or square receesed /surface mounted with required clamps/ fastners. (LED fittings shall be of Philips /Luker/ Hawells make)
Assembling, Installation and servicing of ceiling fans in the existing hooks with required additional hooks/ fastners as the case may be. Ceiling fans will be supplied by FACT.
Supply, fixing and servicing of Angle batten fittings in bath rooms, store area and work area. Required LED lamps will be supplied by FACT
Supply of 20/32 A DP MCB's with enclosures and replacing for AC's/ Water heater, servicing using 3x2.5 sq. mm armoured copper cable through the out side of the building. The cable shall buried in cable trenches of size 300 x 300 mm (max. length 15 M) and clamped over walls, to be glanded/ terminated / connected at the main DB. Required armoured cables will be supplied from FACT. All other materials and fastners required are in the scope of Contractor.
PEEJESS ELECTRICALS
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .