| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹21.2 LAccepted-AOC 00 KANOONGOPURA NORTH MAHILA DISTRICT HOSPITAL BAHRAICH BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | 1 | Accepted-AOC M/s Shakti Enterprises Kashipur | |
| 2 | 2₹21.2 L+₹5,377.24 (0.25%)Rejected-Finance OLD AVAS VIKAS KASHIPUR U S NAGAR | 2 | Rejected-Finance Bidder are second | |
| 3 | 3₹21.2 L+₹7,037.80 (0.33%)Rejected-Finance | 3 | Rejected-Finance Bidder are third |
Tender Value
Refer Docs
EMD Value
₹63,800
Closing Date
20 Mar 2023, 11:00 amClosed
Superintending Engineer
Bijli Bhawan Bazpur Road Kashipur
Laying of LT AB Cable and Supply of its associated decentralized material in different site to 33/11 KV Sub Station 20 No Under EDD Kashipur
2023_UPCL9_55442_1
E Tender No 45/EDC(K)2022-23
Open Tender
Electrical Works
Item Rate
365 days
Kashipur
As Per Tender NIT and Tender Documents
3 documents required · 3 mandatory
₹1,180
Yes
EE EDD Kashipur
₹63,800
Yes
20 Jul 2023
27 Feb 2023
21 Mar 2023
27 Feb 2023
20 Mar 2023
27 Feb 2023
Supply Item
Supply of M.S Stay Clamp for PCC Pole made of M.S. Flate Size 65x6 mm duly Red Oxide Painted with Fitted for 12x35 mm nut and bolts and washer without cracks & burrs. (As Per Specification & Drawing of UPCL)
Supply of M.S. Half Clamp for LT Distribution box of PCC Pole made of M.S. Flate Size 35x5 mm duly Red Oxide Painted with Fitted for 8x25 mm nut and bolts and washer without cracks & burrs. (As Per Specification & Drawing of UPCL)
Supply of M.S Clamp for Dead End Clamp of PCC Pole made of M.S. Flate Size 50x6 mm duly Red Oxide Painted with Fitted for 12x35 mm nut and bolts and washer without cracks & burrs. (As Per Specification & Drawing of UPCL)
Supply of M.S Clamp for Suspension Clamp of PCC Pole made of M.S. Flate Size 50x6 mm duly Red Oxide Painted with Fitted for 12x35 mm nut and bolts and washer without cracks & burrs. (As Per Specification & Drawing of UPCL)
Supply of SMC Three Phase L.T. Distribution Box for connection of LT consumer With in built Panel Lock with key, Al bus bar RYB 25x6 mm & Al bus bar N 40x6 mm. MAKE- (SINTEX/Other IS Complied Reputed Company)
Supply of Shear Head type Insulated Piercing Connector body moulded from high quality mechanical Climate and UV resistant glass reinforced polyamide hot dipped galvanized bolts & contact teeth ABC size 120 Sq mm to 120/95 Sq mm. MAKE- (TYCO/RPG/3M/SICAME/ENSTO)
Supply of Shear Head type Insulated Piercing Connector body moulded from high quality mechanical Climate and UV resistant glass reinforced polyamide hot dipped galvanized bolts & contact teeth ABC size 120 Sq mm to 25/16 Sq mm MAKE- (TYCO/RPG/3M/SICAME/ENSTO)
Supply of Dead End Clamps With I Hook. (As Per Specification & Drawing of UPCL)
Supply of Suspension Clamps With I Hook. (As Per Specification & Drawing of UPCL)
Supply of L.T. Bare Neutral Connectors PG Clamp 95 sq mm to 25 sq mm single bolt. (As Per Specification & Drawing of UPCL)
Supply of L.T. Bare Neutral Connectors PG Clamp 95 sq mm to 95 sq mm double bolt. (As Per Specification & Drawing of UPCL)
Supply of Aluminum Lugs 'O' type size 25 mm for connecting PVC cable 4x25 sq mm. (As Per Specification & Drawing of UPCL)
Aerial Bunch Cable Laying Work
Cartage of PCC Pole by private truck from store centre Rudrapur /Haldwani/ Kashipur to dump store approx. distance 5 to 80 Km. including loading into truck and unloading at work site.
Head Load Cartage of PCC Pole From road to work site approx. distance 5 Km. including loading and unloading.
Cartage of Small line materiral by private truck from store centre Rudrapur /Haldwani/ Kashipur to dump store approx. distance 5 to 80 Km. including loading into truck and unloading at work site.
Head Load Cartage of Small Line Material and decentralized material From road to work site approx. distance 5 Km. including loading and unloading.
Erection of PCC Pole after digging of pit size 0.6×0.6 mtrs & 1/6 length of support on 300×300×75 mm stone pad including fixing with all accessories complete in all respect as per Specification of UPCL.
Fixing of Grouting of stay set complete as per RESPO drawing no. RES-16 with stay rod 16×1800 mm stay wire 7/10 SWG including excavation of earth and grouting of stay in pit with CC 1:4:8 in bottom of pit in size 0.60×0.60×0.60 mtrs, including cost of cement, sand and stone ballast etc. fixing of all accessories complete in all respect as per Specification of UPCL.
Fixing of M.S. earthing rod 20×2500 mm for earthing of support as per RESPO drawing No. RES-12 including digging earth rod 2.5 m deep below ground level connected to support with earth wire 7/16 swg fixing of all accessories complete in all respect as per Specification of UPCL.
Dismantling of following Old ACSR Conductor from Existing LT Line including Re- rolling back its conductor,wire,clamp, insulator, any other wire or items etc.including stacking and transportation of material to the UPCL Central stores 2-40 Km.
3 Phase 4 wire
2 Phase 3 wire
1 Phase 2 wire
Laying,Stringing and sagging of LT A.B Cable size (3x120+1x95/3x95+1x70) including Fixing of Insulated Piercing Connector,Dead end Clamps With I Hook, Suspention Clamp,Holding Clamps, etc. complete in all respect as per Specification of UPCL.
Laying and Fixing Insulated Cable 4x25 sq mm insulated lead.
Fixing of L.T. Distribution Box in all respect.
Labour Charges For Single Phase of Disconnection & Re-Connection of L.T.Consumer Service Connection.& Shiffting of energy meter From Consumer Premises as per norms of UPCL to outside of Premises.
Labour Charges For Three Phase of Disconnection & Re-Connection of L.T.Consumer Service Connection.& Shiffting of energy meter From Consumer Premises as per norms of UPCL to outside of Premises.
M/S SHYAM MOHAN CONTRACTOR
UTTARANCHAL ENTERPRISES
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .