| 1 | L1₹28.7 LAccepted-AOC PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | ₹28.7 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹35.5 L+₹6.8 L (23.8%)Rejected-Finance 3 SHITALNATH FLATE 1 NR KHANPUR JAIN TEMPLE OPP BANK OF INDIA SHAHPUR AHMEDABAD GUJARAT 380001 | AHMADABAD | GUJARAT | 380001 | ₹35.5 L+₹6.8 L (23.8%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹35.6 L+₹6.9 L (24.2%)Rejected-Finance HQ CE SC PUNE | PUNE | MAHARASHTRA | 410301 | ₹35.6 L+₹6.9 L (24.2%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹39.3 L+₹10.6 L (36.9%)Rejected-Finance | ₹39.3 L+₹10.6 L (36.9%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹42.3 L+₹13.6 L (47.3%)Rejected-Finance | ₹42.3 L+₹13.6 L (47.3%) | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹56,000
Closing Date
15 Apr 2022, 6:00 pmClosed
Maj Yogender Singh
GE Navy Porbandar Tija Mile Porbandar
PROVN OF E/M WORKS FOR TECHNICAL STORAGE SHED AT INS SARDAR PATEL UNDER GE NAVY PORBANDAR
2022_MES_509159_2
9113/PBR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Navy
₹56,000
Yes
29 Apr 2022
26 Mar 2022
18 Apr 2022
26 Mar 2022
15 Apr 2022
2 Apr 2022
26 Mar 2022 - 1 Apr 2022
Amount
INTERNAL ELECTRIFICATION
Point wiring with 2.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed for Description a for independent switch socket outlet 6 pin 5/15 Amps complete all as Specified and directed.
One light point controlled by one one way switch
One ceiling fan / exhaust fan controlled by one one way switch
All as per above item No. 1.00 with wire 2.5 sq mm cable for switch socket outlet 3 pin 5 Amps with 2.5 sq mm cable as earth continuity conductor.
All as per above item No. 1.00 but below/parallel the switch board of independent 5 Amps socket in the same vertical/horizontal plane.
Point wiring with 4 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed for Description a for one AC point 20 Amps independent all as directed at site. Note : Seprate circuit of individual point will be drawn from the DB directly for AC point complete all as specified and as directed.
Switch piano 6 Amps 1 module one way complete all as specified and directed.
Ceiling rose surface Bakelite, 65x50mm, 3 terminals complete all as specified and directed.
Modular socket outlet 02 in 01, 03 pin, 06 Amps and 16 Amps, 02 module with shutter complete all as specified & directed.
Modular switch 1 way 16 Amps, 1 modules 230 volts complete all as specified and directed.
Modular socket 16A, 2/3 pin combined, 2 modules 230 volts complete all as specified and directed.
Ceiling fan regulator, stepped type of 0 to 04 rotary steps, electronic, 02 module, hum free, AC, 230 volts, 100 watts, duly ISI marked complete all as specified & directed.
Supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed.
Supply and fixing MCCB, AC 415 V, 50 HZ, fixed type, capacity 100 Amps, 3 Pole, 16 KA, suitable to be fixed in 4/6/8 way TPN DB complete all as specified and directed.
S & F MCB DB double door SPN 12 Way with 200 Amps rated copper bus bar complete all as specified and directed.
MCB SP 6-32 Amps,10 KA breaking capacity 'B' Curve suitable 230 V,50 Hz for lighting and other domestic load complete all as specified and directed by Engineer - in - Charge.
Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level Glvanized earth plate connected with GI earth strip 25x4mm by means of lug, bolts, nuts, check nuts, washers of galvanised iron GI protection pipe 40 mm bore light grade all as shown in elect plate No 3 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work in any type of strata , salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore as watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with CRS Bars 8mm dia at the rate of 100mm centre to centre both way with 12mm dia lifting handle and pit / chamber constructed 50 cm away from the edge in PCC 1:3:6 type C1, Angle iron 40x40x3mm frame for pit cover, fixed in repairs, including testing on completion complete all as specified and directed.
Earthing continuity galvanised iron strip 25 x 4 mm or main earthing lead fixed to wall with clamps or recess or croses or buried in ground or drawn in conduits/pipe or fixed to poles or any other indicated situation for loop earthing etc as required all as specified and directed by Engr-in-Charge.
Supply and fixing ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
Supply and fixing LED down lighter 2 x 2 of minimum 35W complete all as specified and directed.
Exhaust fan 380mm sweep AC, 240 volts connecting with and including 1.5 Sqmm copper conductor, PVC insulated and PVC sheathed three core cable complete all as specified & directed by Engr in charge. Make :Bajaj Maxima Dx 380mm OR equivalent model of make specified in appx 'B' hereinbefore.
Supply and fixing Flood light of minimum 120W luminaire grey powder coated die-cast aluminium housing, IP-65 built in control gear faceted anodised aluminium reflector heat resistant toughened clear glass cover complete all as specified and directed.
Wall mounted fan of 230 Volts, 50 Hz, 1400 rpm, 400mm sweep alongwith louver including all electrical connections complete all as specified and as directed.
EXTERNAL WATER SUPPLY
20mm bore galvanised steel water tubing medium grade ISI marked screwed socketed joints complete with all tube fitting (such as bends, elbow, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions) and fixing complete with clips, wall hooks, wooden plugs or laying in trenches also cutting, screwing and waste and for making forged bends on piping as required at site including taking down the existing pipe line with fitting complete all as specified and as directed.
25mm bore galvanised steel water tubing medium grade ISI marked screwed socketed joints complete with all tube fitting (such as bends, elbow, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions) and fixing complete with clips, wall hooks, wooden plugs or laying in trenches also cutting, screwing and waste and for making forged bends on piping as required at site including taking down the existing pipe line with fitting complete all as specified and as directed.
50mm bore galvanised steel water tubing medium grade ISI marked screwed socketed joints complete with all tube fitting (such as bends, elbow, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions) and fixing complete with clips, wall hooks, wooden plugs or laying in trenches also cutting, screwing and waste and for making forged bends on piping as required at site including taking down the existing pipe line with fitting complete all as specified and as directed.
Gun-metal, ball valve, disc type with iron wheel, screwed both ends for iron pipe, ISI marked of size 20mm bore ,complete all as specified and as directed.
Gun-metal, ball valve, disc type with iron wheel, screwed both ends for iron pipe, ISI marked of size 25mm bore ,complete all as specified and as directed.
Gun-metal, ball valve, disc type with iron wheel, screwed both ends for iron pipe, ISI marked of size 50mm bore ,complete all as specified and as directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation of pipeline and getting out in soft/loose soil complete as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soil complete all as specified.
Removing of excavated materials n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
EXTERNAL ELECTRIFICATION
Supply, install, testing and commissioning Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 50 sqmm 3.5 core suitable for working on 1100 Volts, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed. Note for item No. :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipe shall be measured and paid for separately.
Sand cushioning with a layer of sand 8cm thick before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and directed.
Unreinforced precast concrete cable cover, ISI marked class LV types 2 flat size 250mm x 150mm x 40mm having minimum average breaking load 200Kg, complying IS:5820-1970 made of concrete used of grade M-20, laid flat in trenches over the cable with the length of concrete cover perpendicular to the direction of the cable length, adjacent / abutting each other complete all as specified.
DG SET
Supplying, installing, testing and commissioning, silent Diesel Engine driven generator set, fully wired alternator AC to give an out put of 50 KVA continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hz ± 1%, 1500RPM, as per IS 10001/10002 directly coupled with diesel engine liquid cooled mounted on common base frame complete with fuel tank (service tank) of adequate capacity with fuel line & accessories, with relay panel and switch gears for automatic starting on main failure (outdoor AMF panel with 3.15 MM CRCA MS sheet) as per manufacturer's instructions, vibration damper pads, control panel & other accessories etc and comprising of following complete all as specified and as directed. (b) Diesel Engine: liquid cooled turbo charged with after cooler to deliver suitable BHP at 1500RPM under NTP conditions of BS 5514 and ISO 3046 and conforming to IS 10002 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries of adequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete all as specified and directed. Note:- The DG Set will be initially inspected by representative of Accepting officer in factory premises at work site before dispatch.
GI four wheel trolley suitable for 50 KVA DG Set complete all as specified and directed. (The catalogue of company manufactured Trollies (at least 03 No's) will be submitted for approval of the GE before procurement).
AIR CONDITIONERS
Supply and Install hi wall split type Air conditioner 1.5 Ton capacity indoor & outdoor units complete with cordless remote control unit and within built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EEr 3.2 complete all as specified and directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250 V with output voltage stabilizer at 230 V with accuracy of +/- 2.5 and capacity 4 KVA complete all as specified and directed.
shree chamunda enterprise
K B N TRADERS
Nitesh Enterprise
RAJESH ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .