Executive Engineer
Office of the Executive Engineer,EE(Elec) Division,CSPZ, MLUG Car PArking, Asaf Ali Road, Delhi-110002
Repair/re-strengthening of Main kitchen, Faculty Rooms, Medical college, pump and panel rooms in Hindu Rao Hospital
2024_MCD_190726_1
MCD/TR/3048/2024_6_1_1/1
Open Tender
Electrical Works
Item Rate
180 days
City- SP, CIVIL LINES
refer special conditions
2 documents required · 2 mandatory
₹590
₹13,466
15 Jun 2024
11 Mar 2024
18 Mar 2024
11 Mar 2024
18 Mar 2024
12 Mar 2024
Amount
Wiring work
OD29501/2023-2024:1.10.3. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. (a) Group C
OD29503/2023-2024:1.14.2. Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
OD29502/2023-2024:1.14.3 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
OD29507/2023-2024:1.24.3 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 15/16 amp switch
OD29506/2023-2024:1.24.4 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. b) 3 pin 5/6 amp socket outlet
OD29505/2023-2024:1.24.5 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. c) 6 pin 15/16 amp socket outlet
OD29504/2023-2024:1.24.1. Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. d) 5/6 Amps switch
OD29508/2023-2024:1.26. Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
OD29509/2023-2024:1.27.2 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. (a) 3 Module (100mmX75mm)
OD29510/2023-2024:1.27.4.Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. c) 6 Module (200mmX75mm)
OD29512/2023-2024:1.27.5. Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. d) 8 Module (125mm X 125mm)
OD29511/2023-2024:1.27.6. Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. e) 12 Module (200mm X 150mm)
OD29520/2023-2024:2.3.1. Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 6 way Double door
OD29527/2023-2024:2.10.1. Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single Pole
OD29522/2023-2024:7.7.1. Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required. (a) Upto 35 sq. mm (clamped with 1mm thick saddle)
OD29521/2023-2024:7.7.2. Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required. (b) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
OD29524/2023-2024:2.214. Providing & Fixing following rating and breaking capacity MCCB in the existing cubical panel board including drilling the hole in cubical panel making the connection etc. as required. (a) 125 Amp, 36KA, FPMCCB
OD29523/2023-2024:2.2.15. Providing & Fixing following rating and breaking capacity MCCB in the existing cubical panel board including drilling the hole in cubical panel making the connection etc. as required.(b) 200 Amp, 36KA, FPMCCB
OD29525/2023-2024:19.1 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
LED, Cable etc
122.1.31:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-4C*35 sqmm
122.1.32:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-4C*50 sqmm
122.2.39:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
122.2.189:SITC of metal clad, powder coated, compartmentalized cubical panel board as per CPWD electrical specifications including insulated aluminum bus bars, supports, interconnection, erection of switch gears with depth 30 cm to 60 cm and making provisions for termination of incoming/ outgoing cables/ bus ducting and making foundation etc as required. (Suitable for 400 Amp TP & N)
122.2.121:S/I/T/C of MCCB Sheet Metal Enclosure, 4P, 100-125A
M/s Gyan Enterprises
Bidder Name
M/s Gyan Enterprises
ANOOP ELECTRIC CO
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .