Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.5 LAccepted-AOC MUKALATH VALAYANCHIRANGARA PO PERUMBAVOOR ERNAKULAM KOCHI 683556 | PERUMBAVOOR | ERNAKULAM | KERALA | 683556 | L1 | Accepted-AOC lowest tenderer | |
| 2 | L2₹40.2 L+₹1.5 L (3.86%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹42.3 L+₹3.6 L (9.37%)Rejected-Finance EDALAKADU THABORE P O MOOKANNOOR ERNAKULAM DIST KERALA 683 577 | MOOKANNOOR | ERNAKULAM | KERALA | 683577 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹45.2 L+₹6.5 L (16.9%)Rejected-Finance BLDG NO XXVIII 378A NORTH CHAMPANOOR ANGAMALI SOUTH P O PIN 683 573 | ANGAMALI | ERNAKULAM | KERALA | 683573 | L4 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹45.5 L
EMD Value
₹91,000
Closing Date
25 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682004.
CERTAIN SANCTIONED E/M B/R WORKS UNDER AGE BR ALWAYE
2021_MES_484060_1
8837/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
ALWAYE
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NS KOCHI
₹91,000
Yes
18 Jan 2022
27 Oct 2021
27 Nov 2021
27 Oct 2021
25 Nov 2021
11 Nov 2021
27 Oct 2021 - 10 Nov 2021
60 days
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
Material & Labour for One light point controlled by one switch with PVC single core unsheathed copper conductor multistranded cables FRLS 2.5 sqmm size drawn through and including stove enameled steel conduit of suitable size and all accessories, fire resistant, ISI Marked including 2 mm thick 60mm depth GI sheet pressed terminal box (recessed) with 3mm thick laminated hylam sheet top cover including PVC single core unsheathed copper conductor multistranded cables FRLS 2.5 sqmm as earth continuity conductor and making good the disturbed surfaces of walls/floors/ceiling etc complete all as specified and directed.
Ditto all as per item No 2 but One Exhaust fan point controlled by one switch.
Ditto all as per item No 2 but with cable 4 sqmm for One 3/5 pin socket outlet 16 amps on the independent board.
Supply and Fix flame proof Switch rotary type with termination box in LM6, 16A, single pole 250V complete.
Supply and Fix Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete.
Ditto as per Sl Item No 6 but for 25 Amps.
Supply & Fix CIMFR Certified flameproof LED batten fitting suitable for twin T8 tube of 20 watt, Recommended for Gas/Vapor group of llA & IIB and one 1 & 2, IP65 protected complete.
Supply & Fix CIMFR Certified flameproof LED fitting 60 watt well glass in die cast aluminium housing heat resistant toughened glass, Recommended for Gas/Vapor group of llA & IIB and one 1 & 2, IP65 Protected.
Material & Labour for sub main wiring with two single core 2.5 Sqmm along with earth wire of size 2.5 Sqmm with PVC insulated (FRLS) unsheathed multistranded copper conductor, single core cable drawn through and including stove enameled steel conduit of suitable size on surface/ recessed as required (For continuation of point wiring beyond 7.5 metres). Note: Two Runs of PVC wires of 2.5 Sqmm and One run of 2.5 Sqmm earth wire and one run conduit will be measured as one unit).
Supply & Fix single phase surge protection device type 1 & 2 tested for lighting impulse current 10/350 micro second 50 ka for phase to neutral and 125 ka for neutral to earth, surge protection device tested for nominal discharge current 8/20 micro second 20 ka phase to neutral voltage protection level,<=1.4kv, encapsulated spark technology for line to neutral for type 1 and metal oxide for varistor for type 2 line to neutral. LED indication in line to neutral pole in type 1 and flag indication in type 2 line to neutral, response time for type 1 is less than 100 nano second and type 2 is less than 25 nano second, DIN Rail mounted complete.
Supply & Fix thermoplastic polycarbonate IP66 vertical TPN DB in accordance with IEC60439-3 with 125 / 250 A vertical copper bus bar shock proof, rust free, corrosion free, acid and chemical resistant, fire retardant, self-extinguishing, having high impact against mechanical load, made of halogen and silicon free recyclable material conform to RoHS directive 2002/95/EC, having high grade internally embedded gasket made of Polyurethane (PUR).For better safety enclosure withstand glow wire test at 900 Deg C in accordance with IEC 60 695-2-11, and flame retardant and self-extinguishing in nature. Degree of protection against mechanical load IK 08 (5 Joule) in accordance with accordance with EN IEC 62262 with PE+N terminals and DIN rail at outgoings suitable for fixing MCBs of size 400 x 333 x 129mm, 2 row 18 module. The VTPN DB shall be with transparent or opaque hinged door and with protection cover inside outer door. Make : Hensel Cat Part No KV PC 9118M
Supply & Fix RCCB Double pole, 30mA, 25A complete.
Supply & Fix RCCB Four pole, 40 Amps, 415 volts, 30mA complete.
Material & Labour for One light point controlled by one switch with PVC single core unsheathed copper conductor multistranded cables FRLS 1.5 sqmm size drawn through and including PVC conduit of suitable size and all accessories, fire resistant, ISI Marked including 2 mm thick 60mm depth GI sheet pressed terminal box (recessed) with 3mm thick laminated hylam sheet top cover including PVC single core unsheathed copper conductor multistranded cables FRLS 1.5 sqmm as earth continuity conductor and making good the disturbed surfaces of walls/floors/ceiling etc complete all as specified and directed.
Ditto All as per item No 15 but One ceiling fan point controlled by one switch
Ditto All as per item No 15 but One 3 pin socket outlet 5 amps on the independent board
Ditto All as per item No 15 but with cable 2.5 Sqmm for One 3/5 pin socket outlet 15 amps on the independent board
Supply and fix Switch piano, flush type single pole, one way 5 Amp
Supply and fix Switch socket combination 2 in 1, 5 A flush type
Supply and fix Switch socket combination 5A/16A, 5 in 1 flush type
Supply & Fix Ceiling rose 3 phase PVC polycarbonate, isolated body, 65 x 50mm, 3 terminals.
Supply & Fix stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required.
Supply and fix LED tube light fitting of 20 watt, Extruded aluminium housing enhances safety, high quality PC Diffuser, easy to install Efficacy 125 lumen/watt complete all directed.
Material & Labour for submain wiring with Four runs of single core 6 Sqmm PVC insulated unsheathed multistranded copper conductor cable FRLS, ISI marked along with Two runs of 4 Sqmm multistranded insulated copper conductor cable as earth continuity conductor drawn through and including PVC conduit of suitable size on surface/ recessed as required. Note : Four Runs of PVC wires of 6 Sqmm and Two run of 4 Sqmm earth wire and one run conduit will be measured as one unit).
Supply & Fix Triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB 20A.
Supply & Fix MCB TPN 40 Amps, 415 volts, 10 KA, 'C' Series
Supply & Fix MCB TPN 32 Amps, 415 volts, 10 KA, 'C' Series
Supply & Fix MCB SPN 32 Amps, 240 volts, 10 KA, 'C' Series
Supply & Fix MCB SP 6 to 32 Amps, 240 volts, 10 KA, 'C' Series
Supply laying and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 SqmmX3.5 core Confirming to IS 7098 (Part l) of 1988 passing through pipes, in duct, on poles, in trenches, under road etc. complete all as directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth; for foundation, laying of pipes, cables, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out soft/loose soil.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point .
Supply and spreading locally available dry River Sand for covering and cushioning of UG Cable in trenches complete all as specified.
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm
Supplying laying, jointing and testing Tubes, 'light grade' galvanised, with all fittings and fixed complete to walls or laid under road for passing cables complete of size 40mm all as specified and directed.
Material & Labour for Earthing complete with GI Steel earth plate electrode 600X600X6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) earth plate paced on all side with charcoal mixed with salt to a thickness of 150mm in layers, with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip of size 32X6 mm, soldered and riveted to earth plate. Earth strip will be protected by using 40mm dia bore GI pipe light grade. The earthing includes PCC Pit chamber, RCC pit cover and frame, watering pipe 20mm bore, funnel with wire mess with necessary earth work including disposal of surplus soil to a distance not less than 50 metres etc complete all as shown in electrical plate No. 3 of SSR Part-I 2009,connected to earthing test point complete all as specified or indicated including testing on completion.
Material & Labour for One light point controlled by one switch with PVC single core unsheathed copper conductor multistranded cables FRLS 1.5 sqmm size drawn through and including stove enameled steel conduit of suitable size and all accessories, fire resistant, ISI Marked including 2 mm thick 60mm depth GI sheet pressed terminal box (recessed) with 3mm thick laminated hylam sheet top cover including PVC single core unsheathed copper conductor multistranded cables FRLS 1.5 sqmm as earth continuity conductor and making good the disturbed surfaces of walls/floors/ceiling etc complete all as specified and directed.
Ditto all as per item No 39 but One ceiling fan point controlled by one switch.
Ditto all as per item No 39 but with cable 2.5 sqmm for One 3/5 pin socket outlet 5 amps on the independent board controlled by one flameproof switch one way.
Ditto all as per item No 39 but with cable 4 sqmm for One 3/5 pin socket outlet 5 amps on the independent board controlled by one flameproof switch one way.
Supply & Fix CIMFR Certified flameproof LED fitting 30 watt well glass in die cast aluminium housing heat resistant toughened glass, Recommended for Gas/Vapor group of llA & IIB and one 1 & 2, IP65 Protected.
Supply & Fix flameproof LED aviation obstruction light fitting 15 watt, AC, 220 volts.
Supply & Fix sheet metal enclosure for MCB DB Single pole and neutral 8 ways, 240 volts with 200 Amps rated bus bar, double door complete all as specified and directed.
Supply & Fix sheet metal enclosure for MCB DB Triple pole and neutral 4 ways, 415 volts with 200 Amps rated bus bar, double door complete all as specified and directed.
Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store as directed by Engineer in charge.
Supply & Fix Flameproof ceiling fan AC, 230 V, 1200 mm sweep complete all as specified and directed. Recommended for Gas/Vapor group of llA & IIB and one 1 & 2, IP65 Protected.
Supply & Fix Flame proof switch socket combined 16/32 Amp, 415 volts, 5 Pin (P+N+E+R+Y+B) LM6 termination box, cable entry 3/4" ET- 02 Nos complete.
Supply & Fix Flameproof fan regulator, AC 240 Volts 3/4 step complete.
Supply & Fix MCB TPN 63 Amps, 415 volts, 10 KA, 'C' Series complete.
Supply & Fix RCCB 4 pole, 63 Amps, 415 volts, AC, 100mA complete.
Supply laying and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 4 SqmmX2 core Confirming to IS 7098 (Part l) of 1988 passing through pipes, in duct, on poles, in trenches, under road etc. complete all as directed.
Supply and fix unarmoured 3 core 4 Sqmm aluminium cable, 1100 volts grade, from poles to street light fitting complete all as directed.
Supply & Fix new generation 10 watt Decorative Bollard LED light of one meter height, Energy saving, environmental friendly long life aesthetically designed with symmetrical light distribution, die-cast aluminum landscape luminaries with high power LED as lighting source with IP-65 protection, fixed to ground by means of 2 Nos M10 bolts compete all as specified and directed by Engineer-in-Charge.
Material and Labour for plain cement concrete 1:2:4 type B-1 (using 20mm graded aggregate) for erection of Poles, supporting of bollard lights, repair of road cutting etc, including finishing cement concrete surface even & smooth without using extra cement complete all as specified and as directed.
Material and Labour for pre-stressed concrete Poles of 7.5 meter long class11 having size of 102X152mm at top and 102X281mm at bottom complete all as specified and directed.
Supply and fixing new generation, energy saving and environmental friendly long life street light 72 watt made up of pressure die cast aluminium housing with high power LED lumen efficiency 110 Lumen/watt lighting source and lens embedded PC cover having top opening separate driver compartment with IP-66 Protection and impact resistance of IK07 with 10 KV built-in surge protection device including brackets etc, complete all as specified and directed.
Supply and fix Outdoor type, weather proof, thermoplastic polycarbonate cable Junction Box of size 155X210X92 mm, IP-66/69 in accordance with IEC60529 , with 5 pole terminal suitable to terminate upto 10 sqmm, 4 core and 2 core cables with metric knockouts on side walls complete all as specified and as directed.
Material & Labour for Earthing of Poles with GI wire 4mm dia with galvanised MS earth plate of size 600 x 600 x 6 mm buried directly in ground vertically to a depth not less than 2.25 metre below ground level, earth plate shall be packed on all side with charcoal mixed with salt to a thickness of 150mm in layers, connected to GI earth wire 4mm dia (8 SWG) protected by GI pipe 15mm bore (light grade) and watering pipe 20 mm dia (light grade) of suitable length, with necessary earth work including disposal of surplus soil to a distance not less than 50 metre, PCC pit chamber with RCC cover frame, funnel, wire mesh. The GI earth wire 8 SWG under the earth and on the pole up to a height of 1.5 metre shall also be protected by 15mm dia GI pipe (light grade) & GI pipe to be fixed with poles by the means of 2 Nos flat iron clamp 25 x 3 mm size complete with bolts, nuts and washers etc. all as specified and shown in electrical plate No 3 of SSR Part I - 2009 including testing on completion. Note : - Main earthing lead from earth plate to test point & up to 7.5 Metre to be provided . The cost for the same shall be deemed to be included in the above quoted rate.
Material & Labour for GI steel wire 4mm dia for continuous earthing on poles for guarding carddles hexagonal or rectangular including stringing and connected to earth wire complete all as specified and directed.
Supply & Fix 50 Watt all in one solar LED street light fitting with inbuilt lithium battery, mono crystalline solar panel of 120 WP, Efficiency of 140 Lumen/Watt, MPPT + AC-DC LED Driver, 60 Ah lithium ferro phosphate (LiFePO4) battery, 2 days backup, hybrid with 10 KV - 5 KA SPD operating voltage 180V-230V, PIR motion sensor first hours at 100% brightness, remaining hours till dawn at 30% brightness with active PIR (Active PIR : light glows to100% for 30 seconds upon motion detection, returns to 30% after that) suitable for 6 metre length mounting pole complete all as specified and directed.
Supply & Fix hot dipped GI octagonal pole of 6 metre long with complete arrangements suitable for mounting of LED solar light fitting, with bottom dia 130mm, top dia 70mm with 3 mm sheet thickness and foundation nut bolts complete including necessary earth work excavation, PCC, RCC in (1:1.5:3) as per OEM Drawings attached. (Rate quoted includes all connected works such as excavation, PCC, RCC, Reinforcement, nut bolts, etc) complete all as specified and directed.
Material & Labour for Earthing complete with Copper plate of size 600X600X3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level with top edge of the plate not less than 1.5 metres below normal ground level) earth plate placed on all side with charcoal mixed with salt to a thickness of 150mm in layers, connected to copper earth strip of size 20X3 mm, watering GI pipe 20mm dia light grade of suitable length with necessary earth work including disposal of surplus soil to a distance not less than 50 metres, PCC Pit chamber, RCC pit cover and frame, , funnel with wire mesh etc,. The GI earth wire 8 SWG under the earth and on the pole up to a height of 1.5 meter shall also be protected by 15mm dia GI pipe light grade and GI pipe to be fixed with poles by means of two Nos flat iron Clamp 25X3 mm size complete with bolts, nuts and washers etc, complete all as shown in electrical plate No. 3 of SSR Part-I 2009, connected to earthing test point complete including testing on completion.
Material and labour for earth continuity conductor or main earthing strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed with poles or any other indicated situation for loop earthing etc as required using galvanised iron strip of size 20 X 3 mm including necessary drilling works, jointing, etc complete all as directed by the engineer-in-charge.
Material & Labour for Providing and injecting chemical emulsion for Post Constructional Anti termite Treatment along external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes with cement mortar 1:2 (1 cement: 2 coarse sand) or white cement to match the existing floors in apron complete all as directed by Engineer in charge.
Material & Labour for treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) or white cement to match the existing floors complete all as specified and as directed by Engineer in charge.
Providing and injecting chemical emulsion for Post Constructional Anti termite Treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and as directed by Engineer in charge.
Material & Labour for rendering 15mm thick CM 1:4 finished even and smooth, including taking down cement plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed by Engineer in charge.
Material & Labour for Providing, cement concrete using Type B-0 1:2:4 (using 12.5mm graded aggregate)as for making cement boards including form work & weathering complete all as specified and as directed by Engineer in charge.
Material & Labour for Forming letters, figures etc. of 2cm height by cutting 'V’ grooves in new lime, cement-lime or cement plaster complete all as specified and as directed
Amount of Credit Schedule shall be deducted to arrive the Contract Sum.
M B JAYAVEL
Sreema Enterprises
K R JOSEPH AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .