Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 LAccepted-AOC 306 BAKSHI HOUSE 40 41 NEHRU PLACE NEW DELHI 110019 DELHI | SOUTH EAST | DELHI | 110019 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹2.5 L+₹13,556 (5.77%)Rejected-AOC 189 TEACHEARS COLONY THAKUR PLOT TAJBAG NAGPUR 440024 | NAGPUR | MAHARASHTRA | 440024 | L2 | Rejected-AOC Not Lowest Bidder | |
| 3 | L3₹2.5 L+₹14,161 (6.03%)Rejected-AOC 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L3 | Rejected-AOC Not Lowest Bidder |
Tender Value
₹2.5 L
EMD Value
₹5,085
Closing Date
2 Dec 2019, 6:00 pmClosed
AGM(E-E)
AAI, NIATAM, Birsi, Gondia, MH
Provision of Space and infrastructure for ELPA Training Testing and Certification at NIATAM Gondia Subhead Provision of Split AC units
2019_AAI_36371_1
AAI/GON/NIATAM/AGM-E/ENIT1/AC
Open Tender
Electrical Works
Works
10 days
AAI NIATAM BIRSI GONDIA
As per eNIT
13 documents required · 13 mandatory
₹1,120
AAI
₹5,085
18 Mar 2020
21 Nov 2019
6 Dec 2019
22 Nov 2019
2 Dec 2019
22 Nov 2019
22 Nov 2019 - 28 Nov 2019
Amount
Supply of 1.5 TR capacity BEE 5 Star rated wall mounted inverter type split air-conditioner unit fitted with high EER rotary compressors operating on refrigerant R-410A suitable for operation on 230V, 50 Hz, Single phase, AC supply complete with suitable filter, drain & refrigerant pipe with insulation & electrical connection with 3/4 core flexible copper cable complete as required. (Note: cost of drain (UPVC), refrigerant piping with insulation and electrical cable all upto 3 mtr length is included with this item)
Supply of 2 TR capacity BEE 5 Star rated wall mounted inverter type split air-conditioner unit fitted with high EER rotary compressors operating on refrigerant R-410A suitable for operation on 230V, 50 Hz, Single phase, AC supply complete with suitable filter, drain & refrigerant pipe with insulation & electrical connection with 3/4 core flexible copper cable complete as required. (Note: cost of drain (UPVC), refrigerant piping with insulation and electrical cable all upto 3 mtr length is included with this item)
Installation, testing and commissioning of 1.5 / 2 TR split type air-conditioner (Indoor & Outdoor unit) i/c Copper piping work, providing suitable MS/GI stand for outdoor unit, complete with wall cutting, hole cutting, plastering etc. complete as required.
Supply and Fixing of copper piping (suction & discharge line) including suitable insulation with nitrile rubber and 3/4 core flexible copper cable suitable for 1.5 / 2 TR Split air-conditioning unit including brazing, clamping, chipping and minor civil work complete with all accessories as required.
Supply and fixing of rigid UPVC / flexible drain pipe of 25 mm dia. Including suitable insulation complete with all fittings, U straps, clamps etc.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door
Supplying and fixing 5 A to 32 A rating, Single pole, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 40 A rating, 4P, 415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63A rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing Cable End Box (Loose Wire Box) suitable for 4 way double door, triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required.
Supply of recess type LED lighting fixture suitable for 600 X 600 mm grid false ceiling, made of CRCA housing, with a nominal system lumen output of minimum 3100 lumens, high efficiency diffuser, shall comply with IS 10322 requirements and technical specifications etc. as required. - Similar to Crompton Cat Ref.:LCTLSNE-36-FO-CDL or equivalent. a) Efficacy : 95 Lumens/Watt (Min); b) Life : 50000 burning hours (Min); c) LED Makes : Nichia /Cree /Osram / Philips (Lumiled) / Sharp / Seoul (An undertaking shall be submitted from OEM i.r.o. LED make used in the fixture); d) CRI : 80 (Min); e) THD : Less than 10%. f) Housing : Extruded aluminium / Standard alloy housing; g) IP category : IP 20 or higher. h) Surge Protection : As per relevant IS standard / IEC 61643-II class - 2 & EN 61643-II Type - 2; i) Power Factor : =/> 0.95; j) Total power consumption: Not more than 110 % of rated capacity of LED light; k) Warranty Period: 5 years warranty from actual date of completion of work on complete luminaire including driver / control gear, LED, all accessories etc. Confirmation from OEM shall be submitted.
M K ENTERPRISES
Manish Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .