Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹42.8 Cr
EMD Value
₹42.8 L
Closing Date
15 Dec 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Add.City Engineer Building project
CONSTRUCTION OF FIRE STATION & STAFF QUARTERS AT KATHWADA(TP NO-117, FP NO-364) IN NIKOL WARD, EAST ZONE, UNDER BUILDING PROJECT DEPARTMENT, AMC
368202
2026-27
Open
Civil Works - Buildings
Works
Ahmedabad
1 document required · 0 mandatory · 1 optional
₹18,000
Municipal Commissioner, Ahmedabad
₹42.8 L
21 Nov 2026
21 Nov 2026
21 Nov 2026
15 Dec 2026
21 Nov 2026
180 days
I/We am/are willing to carry out work at __________% above / below (should be written in figures and words) the estimated cost
mentioned above. The amount of my/our tender works out as under
Estimated cost put to tender : Rs. 42,84,33,400.66 Estimated cost put to tender : Rs.
Total : Rs___________ Deduct_____% Below : Rs ___________
Note-1 The contractor should get the sample of material in respect of quality and source of supply or manufacturer approved by
Consultant / AMC in all cases. All such approved samples should be kept at site in the custody of EIC-CMC/PMC/AMC. The tests
for the make in external laboratory in presence of CMC/PMC/AMC to be carried out by Contractor at his own cost as per relevant
latest codes. Reinforcement steel & cement original purchase bills shall be produced to CMC/PMC/AMC as and when asked for.
Note-2 Rate includes for any height, any level, any lead & lift and as per directed by EIC.
Note-3 For Fire Fighting System Autoglow Mandatory Signages and NOC Process and charges of NOC are included.
Signature of Contractor Additional City Engineer
Seal Building Project
Date Ahmedabad Municipal Corporation
AHMEDABAD MUNICIPAL CORPORATION
Construction of Fire Station and Staff Quarters at Kathwada T.P 117 F.P. 364 at Nikol Ward, East Zone, Ahmedabad
city under Building Project Department.
SUBESTIMATE - 01 : STRUCTURAL WORK
S. NO. ITEM DESCRIPTION AMOUNT
B CONCRETE WORK
E MISCELLANEOUS
F DIAPHRAGM WALL
AHMEDABAD MUNICIPAL CORPORATION
Construction of Fire Station and Staff Quarters at Kathwada T.P 117 F.P. 364 at Nikol Ward, East Zone, Ahmedabad city
SUBESTIMATE - 01 : STRUCTURAL WORK
Item no. Item Description Unit Rate Total Qty. Amount
Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the
excavated stuff upto 50 Meter lead.(A) Loose or soft soil
Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out and stacking of useful materials and disposing
off the excavated stuff upto 50 Meter lead.(A) Loose or soft soil
Excavation for foundation for depth from 3.0 m to 5.0 m including sorting out and stacking of useful materials and disposing
off the excavated stuff upto 50 Meter lead.(A) Loose or soft soil
Excavation for depth more than 5.0 m to 6.0 m for excavation for foundation including sorting out and stacking of useful
material sand disposing off the excavated stuff upto 50 Meter lead.(A) Loose or soft soil
Filling available selected / approved stacked excavated earth (excluding rock) (Earth which is stacked at any location
outside the campus non- objectionable place shall be found by the contractor) in trenches, plinth, sides of foundations etc.
in layers not exceeding 20 cm. in depth consolidating 95% of MDD each deposited layer by ramming and watering and
Compaction with Mechanical equipments if possible
Conveyance charge of lime , murrum, building rubbish, earth manure or sludge, and excavated earth and fly ash upto lead of
TOTAL OF EARTH WORK
B CONCRETE WORK
Providing and laying cement concrete 1:2:4 (1-Cement:2-Coarse sand:4-graded stone aggregates 20mm nominal size) and
curing complete excluding cost of formwork in (A) Foundation and Plinth
Providing and laying cement concrete 1:2:4 (1- Cement : 2- Coarse sand : 4- graded stone aggregates 20 mm nominal size)
and curing complete excluding cost of formwork in (COMPOUND WALL)
Providing and laying in position Ready Mixed M- 250 grade concrete for reinforced cement concrete work , using cement
content as per approvedDesign Mix manufactured in fully automatic batching plant and transported to site of work in transit
mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of specified grade for
reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of
centering shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to
accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the
Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement level 450 kg
)(FOUNDATION-SUBSTATION,SECURITY ROOM,HT PANEL ROOM,COMPOUND WALL
Grade Slab Cum 4,853.56 657.65
RCC COLUMN-SECURITY ROOM,HT PANEL ROOM,COMPOUND WALL Cum 4,853.56 17.00
RCC BEAM-SECURITY ROOM,HT PANEL ROOM,COMPOUND WALL Cum 4,853.56 47.04
RCC SLAB-SECURITY ROOM,HT PANEL ROOM Cum 4,853.56 11.36
RCC Lintel, sill, CHAJJA ALL FLOOR Cum 4,853.56 179.23
Item no. Item Description Unit Rate Total Qty. Amount
Providing and laying in position Ready Mixed M-300 grade concrete for reinforced cement conctere work , using cement
content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit
mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of specified grade for
reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of
centering shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:
to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the
Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement level 475 kg )
(Foundation/PEDESTAL)
Providing and laying in position Ready Mixed M-300 grade concrete for reinforced cement conctere work , using cement
content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit
mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of specified grade for
reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of
centering shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:
to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the
Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement level 475 kg )
Providing and laying in position Ready Mixed M-300 grade concrete for reinforced cement conctere work , using cement
content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit
mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of specified grade for
reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of
centering shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:
to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the
Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement level 475 kg )
Providing and laying in position Ready Mixed M-300 grade concrete for reinforced cement conctere work , using cement
content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit
mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of specified grade for
reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of
centering shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:
to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the
Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement level 475 kg )
Providing and laying in position Ready Mixed M-300 grade concrete for reinforced cement conctere work , using cement
content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit
mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of specified grade for
reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of
centering shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:
to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the
Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement level 475 kg )
Item no. Item Description Unit Rate Total Qty. Amount
Providing and laying in position Ready Mixed M-300 grade concrete for reinforced cement conctere work , using cement
content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit
mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of specified grade for
reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of
centering shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS:
to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the
Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement level 500 kg )
Bored cast-in-situ M30 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications and
removal of excavated earth with all lifts and lead upto 1000 m. (Pile diameter- 300 mm)
Providing TMT Bar FE 500D reinforcement for R.C.C. work including bending, binding and placing in position complete upto
floor two level
FOUNDATION & COLUMN & RCC WALL kg 75.46 5,47,164.34
BASEMENT FLOOR LEVEL kg 75.46 1,81,013.77
GROUND FLOOR LEVEL kg 75.46 55,843.03
1ST FLOOR LEVEL kg 75.46 72,629.81
Providing TMT Bar FE 500D reinforcement for R.C.C. work including bending, binding and placing in position complete for
additional lift of reinforcing steel for all R.C.C. work above floor two level.
2ND FLOOR LEVEL kg 76.45 68,724.94
3RD FLOOR LEVEL kg 77.44 70,195.84
4TH FLOOR LEVEL kg 78.43 53,514.35
5TH FLOOR LEVEL kg 79.42 31,303.83
6TH FLOOE LEVEL kg 80.41 27,416.83
7TH FLOOR LEVEL kg 81.40 25,427.26
8TH FLOOR LEVEL kg 82.39 25,427.26
9TH FLOOR LEVEL kg 83.38 25,427.26
10TH FLOOR LEVEL (TERRACE FLOOR LEVEL) kg 84.37 25,427.26
STAIR CABIN / OHWT kg 85.36 33,449.71
TOTAL OF CONCRETE WORK
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and
propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same
for in situ reinforced concrete and plain concrete work in. (A) Foundations Footings Bases of Columns etc. and Mass
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and
propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same
for in situ reinforced concrete and plain concrete work in. (G) Columns PillarsPosts and struts. (1) Square Rectangular
Polygonal in plan.
Item no. Item Description Unit Rate Total Qty. Amount
Extra for additional height of propping and centering where the height of propping and centering exceeds 4 .O M between
20 supporting floor to ceiling including temporary brick or stone pillars for supporting as required. (ii)Height more than 4.0 M.and SQM 386.48 1,911.45
Extra for additional height of propping and centering where the height of propping and centering exceeds 4 .O M between
21 supporting floor to ceiling including temporary brick or stone pillars for supporting as required. (ii) Height more than 5.0M.and SQM 682.01 764.58
Extra for additional height of propping and centering where the height of propping and centering exceeds 4 .O M between
22 supporting floor to ceiling including temporary brick or stone pillars for supporting as required. (ii) Height more than 6.0M.and SQM 573.30 764.58
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and
propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same
for in situ reinforced concrete and plain concrete work in. (C) Vertical surface such as walls (any thickness) partitions and
the like including attached buttresses & string course & the like.
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and
propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same
for in situ reinforced concrete and plain concrete work in. (B) Flat surfaces such as soffits of supspened floors slabs
Landings and the like. (1) Floors etc. upto 200 mm in thickness.
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and
propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same
for in situ reinforced concrete and plain concrete work in. (H) (1) Sides and soffits of Beams Beam Haunchings cantilevers
Girders Bressumers and Lintels not exceeding 1 M. in Depth.
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and
propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same
for in situ reinforced concrete and plain concrete work in. M) Staircase with sloping or stepped soffits including risers and
stringers excluding landing.
(L) Chullah Hoods, weather shades Chhajjas Corbels etc. including edges. Sqm 242.55 410.93
TOTAL OF FORM WORK
Earthwork for embankment including breaking clods, dressing with all lead and lift and including watering rolling and
27 consolidation of subgrade in layers at O.M.C. to required dry density including filling the depression which occur during the CUM 239.65 15.00
process using power roller 8T to 10T.(E)From Borrow area within 3.0KM. lead
Construction of granular sub-base by providing machine crushed B.T. material satisfying MORT&H specification (Fifth
28 revision) of grading I including spreading in uniform layer with motor grader on prepared surface, mixing by mix in place CUM 1,117.00 15.00
method with rotavator at OMC and compacting with vibratory roller to achieve the desired density etc. complete.
Providing and filling PCC in foundation with ordinary cement concrete M15 grade and providing necessary pin headers
including formwork, vibrating, ramming, compaction, leveling, curing, etc. complete.
Providing and casting in situ controlled cement concrete M-30 for wearing coat laid as directed dincluding tamping, vibrating,
finishing, curing and fillingin joints with bitumen complete (For Road on Ground filling only)
Providing and casting in situ controlled cement concrete M-30 for wearing coat laid as directed dincluding tamping, vibrating,
30.1 finishing, curing and fillingin joints with bitumen complete (For Road on Ground filling only) (For Road on Top of basement CUM 5,385.00 210.00
TOTAL OF ROAD WORK
Item no. Item Description Unit Rate Total Qty. Amount
E MISCELLANEOUS
REBAR FIXING IN CONCRETE USING ADHESIVE Providing and fixing heavy duty injection adhesive for rebar of any size
any length fixing in concrete using chemical. The system should be made of two foils consisting of resin and Hardener foil
pack. The installation and the setting instructions should be strictly followed as per the manufacturers recommendations.
Reinforcements will be supplied free of cost at site. (Rate considered as the weighted average of the total rebar quantities)
Providing and fixing in position high-grade PVC water stopper of size 250 mm wide × 10 mm thick at construction /
32 expansion joints in underground water tanks, STP structures and similar water-retaining structures, complete as per RMT 311.00 1,020.00
drawings and directions of Engineer-in-Charge
Trimix flooring - BROOM FINISH
Providing and laying C.C. pavement of mix M-25 with ready mixed/ batch mixed concrete (with use of PP cement) from
batching plant. The ready mixed concrete shall be casted in panel and finished with screed board vibrator, vacuum
dewatering process and finally finished by floating, brooming with machine. Grooves to be made of size 5mm wide and one
third of thickness of concrete within 48 Hours of concreting to form bay of 4 x 4 meters using heavy duty cutting machine
with diamond cutting wheel and filling of the groove with appropriate sealant etc. complete as per specifications and as
directed by the EIC. If trimix concrete shall be laid over on existing concrete surface, bonding agent shall be applied before
laying of concrete at all basements floors. Reinforcement if required shall be paid in relevant tender item.
TOTAL OF MISCELLANEOUS
Item no. Item Description Unit Rate Total Qty. Amount
F DIAPHRAGM WALL
600 mm Thick Diaphragm Wall: Mobilization of all required equipment, machinery, tools, tackles and manpower at site and
setting up the same ready for commencement of work, including construction of M15 grade guide wall; excavation/grabbing
and mucking for 600 mm thick diaphragm wall panels up to the required depth/founding level in all types of soil strata,
including use of hydraulic grab and polymer/bentonite slurry as required, as per approved drawings; providing, placing and
removal of stop ends and casting of M30 grade reinforced concrete for diaphragm wall by tremie pipe method, including
providing and handling of necessary tremie pipes, service cranes, tools and tackles, placing of RMC and removal of stop
ends after casting; providing and fixing approved ISI-marked water stopper at required locations; providing and installing
temporary prestressed soil/ground anchors of required capacity, length and inclination as shown in the approved drawings,
including drilling/boring of anchor holes through soil, providing high-tensile prestressing tendons with required sheathing,
spacer blocks and other accessories, sand and epoxy coating over bonded length, PVC sheathing over unbonded length,
46 grouting with approved resin/cementitious grout including required admixtures, providing and fixing anchorage blocks, Cum 20,148.00 800.00
bearing plates, wedges and all necessary anchorage accessories, stressing of tendons to the specified load using suitable
calibrated equipment, carrying out required testing, and subsequent de-stressing and cutting/removal of exposed portions of
prestressing tendons/anchor heads at the required stage after completion of the basement slab/structural works, including
providing necessary dowels/insert arrangements at specified locations and all associated labour, machinery, equipment,
tools, tackles and incidental works, complete as per approved drawings, specifications and as directed by the Engineer-in-
Charge. Reinforcement steel shall be measured and paid separately as per actual quantity executed.
Providing and laying TMT Bar FE 550/550D reinforcement for R.C.C. work and straightening, cutting, bending, binding &
47 placing in position completed upto any floor any level as per I.S. Standard. complete.as directed by EIC. KG 75.46 1,00,000.00
(1)DIAPHRAM WALL
TOTAL OF DIAPHRAGM WALL
AHMEDABAD MUNICIPAL CORPORATION
Construction of Fire Station and Staff Quarters at Kathwada T.P 117 F.P. 364 at Nikol Ward, East Zone, Ahmedabad
city under Building Project Department.
SUBESTIMATE - 02 : CIVIL WORK
S. NO. ITEM DESCRIPTION AMOUNT
2 MASONARY WORK
2 PLASTER & CLADDING WORK
3 FLOORING & PAVING WORK
3 PAINTING AND POINTING
4 CEILING & PARTITION WORK
4 WATER PROOFING WORK
5 DOOR AND WINDOW WORK
5 MISCELLENEOUS
6 FURNITURE WORK
7 MEPF CIVIL WORK
AHMEDABAD MUNICIPAL CORPORATION
Construction of Fire Station and Staff Quarters at Kathwada T.P 117 F.P. 364 at Nikol Ward, East Zone, Ahmedabad city under Building Project Department.
SUBESTIMATE - 02: CIVIL WORK
Item no. Item Description Unit Rate Total Qty. Amount
Conveyance charge of earth, lime, murrum, building rubbish, manure, garbage, sludge, excavated rock, fly ash, aggregates of any kind
1 executed outside the road site. Rate also includes spreading & levelling etc complete. Internal conveyance above 50 mt done within the Cum
work site is not payable. (R&B 2023-24 Statement No.5 (3.2.1.A.2. Earth) Page no.5
a Lead From 5 Km to 10 Km. Cum 417.67
b Lead From 10 Km to 15 Km. Cum 425.87
c Lead From 15 Km to 25 Km. Cum 433.32
Filling in foundation and plinth with murrum or selected soil in layers of 20cm. thickness including watering, ramming and consolidating etc.
complete. CUM 286.20
TOTAL OF EARTH WORK
B MASONARY WORK
Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in foundation and plinth in
Cement Mortar 1:5. (1- Cement : 5 -fine sand)(B) Conventional
Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. above plinth level upto floor
two level in Cement Mortar 1:5. (1- Cement : 5 -fine sand)(B) Conventional
a Basement Cum 4,283.91
b Ground Floor/ Stilt floor Cum 4,283.91 78.00
c 1st Floor Cum 4,283.91 171.00
Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. for brick work in superstructure
above floor two level in Cement Mortar 1:5. (1- Cement : 5 -fine sand)(B) Conventional
a 2nd Floor Cum 4,324.00 171.00
b 3rd Floor Cum 4,364.09 171.00
c 4th Floor Cum 4,404.18 172.00
d 5th Floor Cum 4,444.27 171.00
e 6th Floor Cum 4,484.36 172.00
f 7th Floor Cum 4,524.45 171.00
g 8th Floor Cum 4,564.54 171.00
h 9th Floor Cum 4,604.63 171.00
i 10th Floor Cum 4,644.72 171.00
j Terrace / Mumty Cum 4,684.81 63.00
(i) Half brick masonry in common brunt clay building bricks having crushing strength not less
6 than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) for half brick masonry in superstructure above plinth level upto
floor two level. (B) Conventional
a Basement SQM 646.70 -
b Ground Floor SQM 646.70 58.00
c 1st Floor SQM 646.70 329.00
(i) Half brick masonry in common brunt clay building bricks having crushing strength not less
7 than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) for brick work in superstructure above floor two level (B)
Item no. Item Description Unit Rate Total Qty. Amount
a 2nd Floor SQM 652.64 329.00
b 3rd Floor SQM 692.73 329.00
c 4th Floor SQM 732.82 329.00
d 5th Floor SQM 772.91 329.00
e 6th Floor SQM 813.00 329.00
f 7th Floor SQM 853.09 329.00
g 8th Floor SQM 893.18 329.00
h 9th Floor SQM 933.27 329.00
i 10th Floor SQM 973.36 329.00
j Terrace / Mumty SQM 1,013.45 -
Providing and filling sunken portion with light weight AAC block bats of size 40–60 mm, including placing, packing and filling voids with
cement sand mortar 1:5 (1 cement : 5 coarse sand) admixed with integral waterproofing compound conforming to IS 2645, properly
8 compacted and levelled, and finishing with 25 mm thick cement sand mortar screed 1:4 laid to required levels and slopes, smooth and cum 6,407.00 1,026.00
ready to receive floor finish, complete as required.
TOTAL OF MASONARY WORK
C PLASTER & CLADDING WORK
Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior plastering upto floor two level and finished even
and smooth in (i)Cement mortar 1:3 (1-cement:3-sand)
a Basement SQM 127.58 -
b Ground Floor SQM 127.58 487.00
c 1st Floor SQM 127.58 1,130.00
Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior plastering above two floor level and for below
10 listed floors and finished even and smooth in (i)Cement mortar 1:3 (1-cement:3-sand) : interior plastering (1) Single coat plaster -
a 2nd Floor SQM 150.74 1,130.00
b 3rd Floor SQM 173.90 1,130.00
c 4th Floor SQM 197.06 1,149.00
d 5th Floor SQM 220.22 1,130.00
e 6th Floor SQM 243.38 1,149.00
f 7th Floor SQM 266.54 1,130.00
g 8th Floor SQM 289.70 1,130.00
h 9th Floor SQM 312.86 1,130.00
i 10th Floor SQM 336.02 1,130.00
j Terrace / Mumty SQM 359.18 269.00
20mm thick sand faced cement plaster on walls upto height 10 metres above ground level consisting of 12mm thick backing coat of
C.M. 1:3 (1-cement : 3-sand) and 8mm thick finishing coat of C.M. 1:1 (1-cement : 1-sand) etc. complete.
b Ground Floor SQM 297.68 554.00
c 1st Floor SQM 297.68 545.00
20mm thick sand faced cement plaster on walls upto height 10 metres above two floor level and for below listed floors consisting of
12 12mm thick backing coat of C.M. 1:3 (1-cement : 3-sand) and 8mm thick finishing coat of C.M. 1:1 (1-cement : 1-sand) etc. complete. (2) -
Two coat plaster
a 2nd Floor SQM 297.68 545.00
Item no. Item Description Unit Rate Total Qty. Amount
b 3rd Floor SQM 324.14 545.00
c 4th Floor SQM 350.60 547.00
d 5th Floor SQM 377.06 545.00
e 6th Floor SQM 403.52 547.00
f 7th Floor SQM 429.98 545.00
g 8th Floor SQM 456.44 545.00
h 9th Floor SQM 482.90 545.00
i 10th Floor SQM 509.36 545.00
j Terrace / Mumty SQM 535.82 250.00
Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls for interior plastering upto floor
two level and finished even and smooth in (ii) Cement mortar 1:4 (1-cement :4-sand)
a Basement SQM 155.61 -
b Ground Floor SQM 155.61
c 1st Floor SQM 155.61 148.00
Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls for interior plastering above two
14 floor level and for below listed floors and finished even and smooth in (ii) Cement mortar 1:4 (1-cement :4-sand) (1) Single coat plaster -
a 2nd Floor SQM 178.77 148.00
b 3rd Floor SQM 201.93 148.00
c 4th Floor SQM 225.09 148.00
d 5th Floor SQM 248.25 148.00
e 6th Floor SQM 271.41 148.00
f 7th Floor SQM 294.57 148.00
g 8th Floor SQM 317.73 148.00
h 9th Floor SQM 340.89 148.00
i 10th Floor SQM 364.05 148.00
Providing 10mm thick cement plaster in single coat for interior plastering upto floor two level for plastering on ceilings and sofits of
15 stairs upto floor two level instead of plastering on walls. and finished even and smooth in (i)Cement mortar 1:3 (1-cement:3-sand) -
a Basement SQM 152.15
b Ground Floor SQM 152.15 532.00
c 1st Floor SQM 152.15 1,080.00
Providing 10mm thick cement plaster in single coat for interior plastering above two floor level and for below listed floors for
16 plastering on ceilings and sofits of stairs upto floor two level instead of plastering on walls. and finished even and smooth in (i)Cement -
mortar 1:3 (1-cement:3-sand)
a 2nd Floor SQM 175.31 1,080.00
b 3rd Floor SQM 198.47 1,080.00
c 4th Floor SQM 221.63 1,091.00
d 5th Floor SQM 244.79 1,080.00
e 6th Floor SQM 267.95 1,091.00
f 7th Floor SQM 291.11 1,080.00
g 8th Floor SQM 314.27 1,080.00
Item no. Item Description Unit Rate Total Qty. Amount
h 9th Floor SQM 337.43 1,080.00
i 10th Floor SQM 360.59 1,080.00
j Terrace / Mumty SQM 383.75 22.00
Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior plastering upto floor two level and finished even
and smooth in (i)Cement mortar 1:3 (1-cement:3-sand) and for finishing with a floating coat of neat cement slurry.
a Basement SQM 175.31
b Ground Floor SQM 175.31 15.00
c 1st Floor SQM 175.31 42.00
Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior plastering above two floor level and for below
18 listed floors and finished even and smooth in (i)Cement mortar 1:3 (1-cement:3-sand) : interior plastering (1) Single coat plaster and for -
finishing with a floating coat of neat cement slurry.
a 2nd Floor SQM 198.47 42.00
b 3rd Floor SQM 221.63 42.00
c 4th Floor SQM 244.79 42.00
d 5th Floor SQM 267.95 42.00
e 6th Floor SQM 291.11 42.00
f 7th Floor SQM 314.27 42.00
g 8th Floor SQM 337.43 42.00
h 9th Floor SQM 360.59 42.00
i 10th Floor SQM 383.75 42.00
j Terrace / Mumty SQM 406.91 39.00
WET CLADDING POLISHED GRANITE : Providing and fixing machine cut, composite patterned wall wet cladding out of 18-20mm thick
mirror polish granite machine cut, machine polished to walls and columns. Stone fixed with required stainless steel pins / dowels / cramps
including drilling holes, making notches etc. for securedly fixing with pins / cramps to wall. Stone fixed in position with approved readymix
19 ploymer based adhesive in line and level and in pattern as shown in the drawing. Joints cleaned, grouted with approved ready made SQM 4,546.00 1,138.00
ploymer modified grout or cured and cleaned, further to include required double legged independent scaffolding etc. complete to the
satisfaction of the EIC.
Washed stone grit plaster on exterior walls height upto 10 metre above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1
cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per
20 square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with SQM 647.00 1,138.00
groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone
chippings ,complete as per specification and direction of Engineer-in-charge (payment for providing grooves shall be made separately).
STONE CRETE for above 10m level :
Washed stone grit plaster on exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof, in
two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying
21 cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 113.00 -
2 stone chipping 10 mm nominal size) using white cement and selected pigment, in panels with groove all around as per approved pattern,
including scrubbing and washing the top layer with brushes and water to expose the stone chippings, complete as per specification and
direction of Engineer-in-charge (payment for providing grooves shall be made separately).
Item no. Item Description Unit Rate Total Qty. Amount
GROOVE IN STONE CRETE : 'Forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using
m wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove RMT 40.00 341.40
complete as per specifications and direction of the Engineer-in-charge . 15mm wide and 15mm deep groove.
TOTAL AMOUNT PLASTER & CLADDING WORK
TOTAL AMOUNT PLASTER & CLADDING WORK
D FLOORING & PAVING WORK
Granite Flooring - Leather Finish : Providing and laying lether finish Granite stone flooring in required design and patterns, in linear as
well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average)
22 thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry SQM 1,921.00 751.00
admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the
Engineer-in-Charge. lether finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent
Granite Treads - Leather Finish : 'Providing and fixing 20mm thick approved up to 600mm wide leather finish Granite stone treads of length
of step and machine cut, machine polished. Treads to be rounded at front and all exposed edges machine polished. Further treads to have
23 edge polished chamfering with 3 Nos.. (6mm x 3mm deep) grooves on top at front or as detailed in drawing for antiskid effect as shown in SQM 3,641.00 159.00
the drawing. Treads fix to be using approved adhesive over cement concrete screed joints grouted with approved matching coulour grout,,
curing, cleaning, polishing etc. all complete at all heights and leads to the approval of the Engineer in charge.
Granite Skirting / Riser / vertical - Leather finish : Providing and laying Granite stone slab 25mm thick in risers of steps,skirting Dedo
24 and pillars laid on 10mm thick cement mortar 1:3 (1-Cement : 3 coarse sand) and jointed with gray cement slury mixed with pigment to SQM 2,323.00 144.00
match the shade of slab including rubbing and polishing etc. complete.
Granite Flooring - Polished : Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as
curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick
25 base of cement mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with SQM 2,250.00 274.00
pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-
Charge. Polished granite stone slab of colour black, cherry/ruby red or equivalent.
Granite Skirting / Riser / vertical - Polished : Providing and laying GRANITE STONE SLAB 25mm thick in risers of steps,skirting Dedo
26 and pillars laid on 10mm thick cement mortar 1:3 (1-Cement : 3 coarse sand) and jointed with gray cement slury mixed with pigment to SQM 2,511.00 8.00
match the shade of slab including rubbing and polishing etc. complete.
Polishe Kota Stone Flooring : Providing and laying polished Kota stone slab flooring over 20mm (Average) thick base of cement mortar
27 1:6 (1-cement : 6-coarse sand) or L.M. 1.1.5 laid over and jointed with grey cement slurry including rubbing and polishing etc. complete. (B) SQM 1,085.48 291.00
Polishe Kota Stone Skirting / Riser / vertical : Providing and laying polished kota stone slab 25mm thick in risers of steps,skirting Dedo
28 and pillars laid on 10mm thick cement mortar 1:3 (1-Cement : 3 coarse sand) and jointed with gray cement slury mixed with SQM 1,176.03 480.00
pigment to match the shade of slab including rubbing and polishing etc. complete.
Vitrified Tile Flooring - polished : P & L 24" x 24" vitrified 8 mm thick tile flooring over 20 mm (average) base of cement mortar 1:6 (
cement: 6 coarse sand) on new surface or fixing on existing flooring by adhesive material including dismentaling of existing flooring and
29 jointed with color cement slurry including finised with flush pointing & cleaning the surface etc. complete for shade as per architect/client SQM 1,261.58 3,116.00
Item no. Item Description Unit Rate Total Qty. Amount
Vitrified Tile Flooring - antiskit : P & L 24" x 24" vitrified 8 mm thick tile flooring over 20 mm (average) base of cement mortar 1:6 (
30 cement: 6 coarse sand) on new surface or fixing on existing flooring by adhesive material including dismentaling of existing flooring and SQM 1,383.99 2,524.00
jointed with color cement slurry including finised with flush pointing & cleaning the surface etc. complete for antiskit
Vitrified Tile Skirting / Dado / Vertical (Rooms) : Providing and laying Vitrified tiles 8 to 10 mm thick , 24'' x 24'' in skrting risers of steps
31 and dedo on 10mm thick cement plaster 1:3 (1-cement : 3- coarse sand) and jointed with white cement slurry SQM 1,130.15 631.00
Ceramic Tile Flooring : Providing and laying Ceramic tiles 6mm thick in flooring treads of steps and landing laid on a bed of 12mm thick
cement mortar 1:3 (1-cement : 3-coarse sand ) finishing with flush pointing in white cement.
Ceramic Tile Skirting / Dado / Vertical : Providing and layingCeramic tiles 6mm thick in skrting risers of steps and dedo on 10mm thick
cement plaster 1:3 (1-cement : 3-coarse sand) and jointed with white cement slurry
Polished Granite Coping : Providing and fixing premoulded and prefinished, machine cut polished 18-20 mm thick granite stone for
coping, parapet top and similar locations of required size, approved shade, colour and texture laid using approved adhesive over cement
34 concrete screed (paid separately), joints grouted with approved matching colour grout, epoxy touch ups, including rubbing, curing, moulding SQM 6,980.00 165.00
and polishing to edges to give high gloss finish etc. complete at all levels, as per sample approved by Engineer in-charge.
Sandwich Kitchen Platform : 'Providing & Fixing Sandwich type Kitchen Platform of Min. 750mm wide using Top 18mm thick granite of
approved shade and sample and bottom 25mm thick single side Polished kota stone with 25 mm thick screed of cement mortar 1:3 With
35 granite Facia Patti. and vertical End granite supports. The stone shall be fixed by chassing in to the wall surface and supported vertically SQM 3,159.00 222.00
with 25mm thick sandwich kota stone support to complete job as directed by Architect/Engineer -in-charge. It is inclusive of all necessary
chasses & civil work, holes and cuts etc. comp. No extra payment shall be made in any case.
Toilet Wash Basin Counters - Providing & Fixing Granite wash basin counter of granite of Min. 600mm wide using Top 18mm thick
granite having drop facia with epoxy adhesive to 25mm tk. marine play wood along the platform as per typical details given in. ref. drawing
36 of approved shade and sample. It allows for all necessary mirror polish moulding, edge polishing, chamfering, etc. completed. Necessary SQM 4,418.00 11.00
arrangement of MS 50mmx50mmx2mm customized bracket fixed to given wall to support granite top shall be part of this item. It is inclusive
of all necessary chasses & civil work, holes and cuts etc. comp. No extra payment shall be made in any case.
Granite Urinal Partitions : Providing and fixing stone slab with table rubbed, edges rounded and both side polished, of size 450x900 mm
deep and 40 mm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the
37 chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per SQM 1,793.00 25.00
direction of Engineer-in-charge and finished smooth.Granite Stone of approved shade
Providing and fixing pre-cast Rubber Dye / steel Dye inter locking concrete block 60mm thick with grade of concrete M300 pnumatic
compressed / vibrated mechanically and as per approved design Confirming to IS 15658 : 2006 including 35 mm Sand layer for levelling
38 and filling the joint with sand in proper line and level as per guidlines of IRC : SP 63-2018 etc. Complete. SQM 680.10
Providing and fixing pre-cast concrete kerbstone of gray cement based concrete block 30cm length,30cmheightand15cmthickofM200grade
39 concret as per approved design and including excavationfor fixing inproper lineandlevel,filling the jointwithC:M1:3 (1cement:3fine sand) etc RMT 376.43
Providing and laying cushioning layer on R.C.C. Slab consisting of 75mm thick lime, concrete using brick aggregate of 20mm nominal size
mortar compresing of 1-Lime : 2- fine sand)
Ramp Straps: Providing and fixing granite bands in staggered layer at ramps fall using 20mm thick fixed to sloping wall having polished
41 edges/ hand tool edge with approved waterproof adhesive, etc. complete as detailed in drawing and satisfaction of Engineer in charge. SQM 2,397.00 5.00
TOTAL AMOUNT FLOORING & PAVING WORK
TOTAL AMOUNT FLOORING & PAVING WORK
E PAINTING AND POINTING
Wall painting (two coats) with plastic emulsion paint of approved brand and manufacture on undecorated wall surface to give an even shade
42 including throughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth. SQM 118.63 12,092.00
Item no. Item Description Unit Rate Total Qty. Amount
Finishing wall with water proofing cement paint of on wall surfaces (Two coats) to give an approved brand and manufacture and of required
43 shape even shade after thoroughly brushing the surface to remove all dirt and remains of loose powered materials. + for finishing with SQM 103.53 11,372.00
cement paint on ceiling and sloping roofs.
Exterior Texture Paint : Providing and applying exterior textured paint system on prepared surfaces, comprising 1 coat primer, 2 coats
44 textured finish, and 2 coats clear protective top coat, including all materials, labour, surface preparation, scaffolding, and complete as per SQM 164.00 6,253.00
specifications.
White washing with lime on wall surface (onecoats) to give an even shade including thoroughly booming the surface to remove all dirt, dust;
mortar drops and loose scales of lime washand other foreign matter.
Metal surface primer+paint : Applying priming coat over new steel and other metel surface after and including preparing the surface by
throughly cleaning, oil,grease, dirt and other foreign matter and scoured with brushes fine steel wood, scrapers and sand paper with ready
mixed priming paint brushing red lead. Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint,
46 brushing, interior to give an even shade including cleaning the surface an even shade including cleanicn the surface of all dirt, dust and SQM 121.28 414.00
other foreign matter. Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint, brushing, interior
to give an even shade including cleaning the surface an even shade including cleanicn the surface of all dirt, dust andother foreign matter
TOTAL AMOUNT PAINTING AND POINTING
TOTAL AMOUNT PAINTING AND POINTING
F CEILING & PARTITION WORK
GYPSUM BOARD CEILING : Providing and fixing suspended false ceiling at all heights using a galvanized steel framework with ceiling
drop up to 1000 mm, designed to satisfy L/400 deflection criteria under 200 Pa load. The ceiling shall comprise single layer 12.5 mm thick
tapered edge gypsum board conforming to IS 2095 (Part 1):2023 Type A / EN 520 Type A or equivalent approved standards, consisting of
aerated gypsum core encased in and firmly bonded to paper liners, having required thermal and mechanical properties.
The framework shall be made of galvanized steel sections conforming to relevant standards, manufactured from CR1 grade steel with
minimum yield strength of 300 MPa and appropriate corrosion protection (minimum 120 GSM or equivalent coating), including perimeter
channels fixed along walls/partitions at specified intervals using approved fasteners suitable for the substrate, ceiling angles suspended
from the soffit using cleats and anchors, intermediate channels, and ceiling sections fixed at required spacing to form a rigid grid. The
47 gypsum boards shall be fixed to the framework using suitable drywall screws at specified spacing. All joints shall be treated with approved SQM 1,014.00
jointing compound and jointing tape, finished in multiple layers to achieve a smooth, seamless surface ready to receive paint. The work
shall include making necessary cut-outs and providing framing for light fixtures, diffusers, grills and other services, complete in all respects
as per approved drawings and directions of the Engineer-in-Charge. The item shall include all materials, labour, scaffolding, tools and
tackles, all leads and lifts, complete, but excluding final painting.
MOISTURE RESISTANT GRID CEILING :Providing and fixing tiled false ceiling in true horizontal level using 600x600 mm grid system with
hot-dip galvanized steel sections, comprising main runners (~24x38x0.3 mm) at 1200 mm c/c, cross tees (~24x25x0.3 mm) at 600 mm c/c
and secondary tees forming 600x600 mm grid, supported on GI wall angles (~24x24x0.4 mm) fixed along periphery. The framework shall be
suspended from soffit using cleats, hangers and approved fasteners at specified spacing, ensuring proper alignment and level. All sections
shall be of galvanized steel conforming to relevant standards with minimum 90–120 GSM coating.
48 The grid shall accommodate 12–12.5 mm thick square edge gypsum/plasterboard tiles of size 595x595 mm conforming to IS 2095 or SQM 1,179.00 227.00
equivalent, factory laminated with decorative/facing finish and sealed edges, laid in the grid to form a uniform ceiling. The system shall
include all necessary supports, hangers, fasteners and accessories, complete in all respects as per drawings and directions of the Engineer-
Item no. Item Description Unit Rate Total Qty. Amount
GYPSUM GRID CEILING : Providing & Fixing of Soft Fibre Acoustical Suspended Ceiling System with Optra Beveled Tegular Edge Tiles
With Armstrong Silhouette 15mm Exposed Grid. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9, Light Reflectance
≥85%, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600x600x15mm, suitable for Green
Building application, with Recycled content of 66% GW & 74% RW. The tile shall be laid on Armstrong Silhouette profile grid system with
15mm white flanges incorporating a 6mm central reveal in white/black colour and with a web height of 38mm and a load carrying capacity of
minimum 7.90 Kgs/M2 (as per standard installation layout mentioned below) & pull out strength of 100Kgs. Silhouette, Main Runners &
Cross Tees to have mitred ends & “birdsmouth” notches to provide mitred cruciform junctions. The T Sections have a Galvanizing of
49 grams per M2 and need to be installed with Suspension system of Armstrong make. The Tile & Grid system used together should carry a 10 SQM 1,179.00 274.00
year warranty.ARMSTRONG SUSPENSION SYSTEM accessories manufactured and supplied by Armstrong World Industries consisting of
M6 Anchor Fasteners with hanger hole, pre Straightened Hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344-413
MPa and a minimum pull strength of 110 kgs. (Adjustable hook clips of 0.7mm thick, galvanized spring steel can also be used for
installation purpose as an additional accessory. The adjustable clip also consists of a 4 mm aquiline wire to be used with the main
runner).Hanging system up to 1.5 M (for above mentioned item)
Item no. Item Description Unit Rate Total Qty. Amount
Cement Board False Ceiling - Designing, Fabricating, testing, installing and fixing of Heavy-duty GI Sections, 8mm thk. Cement fibre
sheet fixed with self-tapping screw, keeping 3-4 mm gaps at every joint. Acrylic Sealant will be applied to all cement board joints. All the
50 joints are treated with 150 mm-wide 160 GSM Fibre Mesh and Styrobond DP. Terabond A (Mixing Ration with water 1:5) will be applied to SQM 2,440.00
the cement board. Finish TOP Coat - Exposed Concrfete Finish Decorend will be applied in two layers.
GYPSUM PARTITION:-100.0mm thick gypsum partition consist of Metal framework partition having maximum reachable height of 3400mm
satisfying L/240 criterion at 200Pa, possessing fire rating of 60mins, tested in accordance to BS-476 Part 20 & 22 & sound insulation (Rw)
of 42dB, tested in accordance to ISO 10140-2/ASTM E90 & spectrum adaption term as per ISO 717-1, having Severe duty rating as per BS
5234 part 2. Partition comprises of double layer, tapered edge Gypsum Board, certified GreenPro by CII, 100% recyclable, class 1 rated as
per BS 476 -7 & strategic location of manufacturing plants results in lower carbon emissions. Partition includes double layer of 12.5mm thick
gypsum board consists of an aerated gypsum core encased in, and firmly bonded to strong paper liners and conforming to IS 2095 Part
1:2023 Type A / EN 520:2004 Type-A, having thermal conductivity 0.16w/m°k having flexural strength – {Longitudinal > 550N & transverse >
210N}, 3rd Party EPD verified in accordance to EN 15804 and ISO 14025 with a Global Warming Potential of 4.73 kg CO2 equivalent/m2
on either side of the framing. Metal frame work, in compliance with BS EN 14195 & manufactured using CR1 Grade GI Sheet as per IS
having yield stress of 300MPa & tensile strength of 340MPa with AZ150 finish abiding to IS 15961 & tested for 500hrs of salt spray test as
51 per ASTM B117 with a Global Warming Potential of 3.16 Kg CO2 per Kg from third party verified EPD as per ISO14025:2006, includes SQM 1,707.00
48x34x36x0.5mm C-Stud with lip of 6.5mm and H-cutout on web enabling the services to pass, having moment of inertia 26627mm4 about
major axis, positioned at 610mm c/c in 50x32x32x0.5mm Floor Channel & 50x32x32x0.5mm Ceiling Channel with flanges bend at 5° acute
angle. Floor & Ceiling Channel is anchored with mechanical anchor Ø8x45mm having Pull Out strength of 6.8KN or Nail, fixed at 600mm
c/c in Center. 48x40x40x0.5mm Noggin Channel to be placed between the studs, behind the horizontal board joint. Inner & Outer layer of
Boards to be Screw fixed with Drywall Screw of 25mm & 35mm at spacing of 600mm & 300mm respectively. Edges & joints to be finished
with jointing compound conforming to ASTM C475 &Paper tape. Periphery & cut-outs of the partition to be treated with suitable Fire &
Acoustic Sealant.
TOTAL AMOUNT CEILING & PARTITION WORK
TOTAL AMOUNT CEILING & PARTITION WORK
G WATER PROOFING WORK
RAFT / GRADE SLAB: Supplying and installing waterproofing treatment for Raft/Grade slab by using fully bonded HDPE sheet, membrane
1.2mm thick before casting of the RCC Raft.
The preapplied, fully bonded HDPE sheet membrane to get bonded to the underneath of the poured concrete used as base/ raft slab to
resist lateral water migration. The fully bonded HDPE sheet membrane shall consist of a thick HDPE film, a highly aggressive pressure
sensitive adhesive and Granuels which bonds integrally to poured concrete of base slab.1) Resist hydrostatic pressure of - 60 +/- 6 m head
of water (as per ASTM D5385)
2) Peel Adhesion to concrete- Minimum 1.5 N/mm
3) Puncture Resistance – 800 +/- 100 N
4) Tensile strength -21 +/- 3 N/mm2
5) Engloation :400%
6) Bare HDPE Thickness > 0.8 mm
52 7) Joint Strength at overlap - 15 +/- 2 N/mm SQM 901.00
The fully bonded HDPE sheet membrane shall be installed with heat welded method by accurately positioning sheets by overlapping them
for 100 mm. The membrane shall be laid over the concrete blinding having smooth dried surface including necessary removal of release
liner while applying, necessary overlaps between the membranes and fixing overlaps by Double sided adhesive tape firm rolling onto the
surface to get a tight seal, etc. Hot applied materials or protective screed shall NOT be permitted. All systems to be installed as
per manufacturer's recommendations, etc. complete with all lead and lift for all materials and labour and as directed by Engineer in-charge.
This membrane shall be terminated Horizontally and fixed using EVA at the junctions/ pheriphary of the basement wall & Raft as per
Manufacturers recommendation, including all materials & labour, etc, all complete.
The membrane shall conforms to basement waterproofing protection to grade 3 as defined in BS 8102:2009. The fully bonded HDPE sheet
waterproofing membrane shall have following minimum properties :
Item no. Item Description Unit Rate Total Qty. Amount
1) Resist hydrostatic pressure of - 60 +/- 6 m head of water (as per ASTM D5385)
2) Peel Adhesion to concrete- Minimum 1.5 N/mm
3) Puncture Resistance – 800 +/- 100 N
4) Tensile strength -21 +/- 3 N/mm2
5) Engloation :400%
6) Bare HDPE Thickness > 0.8 mm
7) Joint Strength at overlap - 15 +/- 2 N/mm
The fully bonded HDPE sheet membrane shall be installed with heat welded method by accurately positioning sheets by overlapping them
for 100 mm. The membrane shall be laid over the concrete blinding having smooth dried surface including necessary removal of release
liner while applying, necessary overlaps between the membranes and fixing overlaps by Double sided adhesive tape firm rolling onto the
surface to get a tight seal, etc. Hot applied materials or protective screed shall NOT be permitted. All systems to be installed as
per manufacturer's recommendations, etc. complete with all lead and lift for all materials and labour and as directed by Engineer in-charge.
This membrane shall be terminated Horizontally and fixed using EVA at the junctions/ pheriphary of the basement wall & Raft as per
Manufacturers recommendation, including all materials & labour, etc, all complete.
FOOTINGS : Portective Coating for Footings.
Surface Preparation: Providing and laying water proofing treatment to horizontal and vertical surfaces of podium slabs, including cleaning
the surface with wire brush, treating all surface cracks, construction joints and honeycombs by grouting with specialised non shrink
53 grout,coving preparation at wall - slab joint and preparation of surface in all aspects to receive the waterproofing. Waterproofing Coating- SQM 639.00
Providing and application of a two component, moisture insensitive coal tar epoxy resistant of roots and acid/contaminent resistant.
Retaining Wall Waterproofing :
Surface preparation: The substrate must be free of loose aggregate, slush, mud, sharp protrusions and stagnated water. Ground water level
needs to be kept under the PCC level, continues dewatering to be done till completion of concreting. The surface of retaining wall should be
54 dry (moisture content <5%) before application of primer.Construction Joint treatment: All the construction joints in retaining wall should be SQM 1,104.00
opened in a V groove manner of size 10mm X 10mm using a grinder or suitable tool & should be sealed with Polymer Modified Mortar
prepared with ReArm Bond SBR 45 or equivalent @5 liter per 50 kg bag of cement.
Filling of tie rod holes: The tie rod holes shoukd be filled with Polymer modified mortar prepared using ReArm Bond SBR 45 or equivalent
@5 liter per 50 kg bag of
Preparation of chamfer or vatta at wall & raft junction: The junction between RCC raft & retaining wall should be treated by preparation of
vatta of size min. 50mm X 50mm with Polymer Modified Mortar prepared ReArm Bond SBR 45 or equivalent @5 liter per 50 kg bag of
Preparation of chamfer or vatta at wall & raft junction: The junction between RCC raft & retaining wall should be treated by preparation of
vatta of size min. 50mm X 50mm with Polymer Modified Mortar prepared ReArm Bond SBR 45 or equivalent @5 liter per 50 kg bag of
Protection of membrane: The SBS Membrane should be protected by means of 6-8 mm thick dimple boards against any physical damage
before commencement of backfilling.
Termination of Membrane on retaining wall: The SBS membrane should be secured with a Metal strip on retaining wall (300 mm
above the ground level) used in conjunction with polyurethane sealant between the membrane and Metal Strip. The termination bar / Metal
55 strip must be installed directly into the wall width and mechanically fixed at c/c using appropriate fasteners. A bead of Sealant is applied RMT 291.00
along the top edge of the termination bar.
Item no. Item Description Unit Rate Total Qty. Amount
TERRACE WATERPROOFING : Surface Preparation: Providing and laying water proofing treatment to horizontal and vertical surfaces of
concrete, including cleaning the surface with wire brush, treating all surface cracks, construction joints and honeycombs by grouting
56 with specialised non shrink grout,coving preparation at wall - slab joint and preparation of surface in all aspects to receive the SQM 2,091.00 451.00
Injection Grouting (If required): Providing Chemical injection treatment in the form of pressure grouting to the cold joint by injecting
cement slurry mixed with grout admixture ArmGrout Additives @ 250 gms.per bag of cement, in the required consistency through the pre
fixed PVC nozzles in the 10mm dia holes, fixing of PVC nozzles with quick setting compound ReArm Fix 10S of MYK Arment or equivalent
and final cutting the projected nozzles and sealing off the PVC nozzles after the injection operation is over with quick setting compound , no
shrink rapid setting mortar compound, finishing, curing etc. as per manufacturers specification and as directed.If any lekages found in pre
ponding then this need to be done.
Coving: Providing and Applying at the junction of slab and vertical offsets with Cement Mortar 1:4 and admixed with SBR polymer at
dosage of 5Ltr per 50kg cement.
Application of Primer: Apply Epoxy based primer over well prepared surface at 200-400 gm per SQMr.
Application of Polyurethane waterproof coating: Providing and applying Two coats of liquid applied single component polyurethane
based waterproofing system . It has to be applied @1.95 kg/SQMr to achieve a thickness of 1.2 mm in two coats.The membrane will have
the following technical parameters: Tensile Strength : 2 N/mm² ,. Elongation at break : 400% , Adhesion To concrete: >1.5 N/mm²
Providing and laying 150 Gsm Geo fabric membrane as separation layer
Protection Screed:Horizontal Areas: Providing and Laying M25 grade screed concrete in 1:100 to a average thickness of 100 mm mixed
with Integral Waterproofing admixture at the dosage of 125 ml/bag of cement over waterproofing layer to a minimum thickness of 75 mm
as per site requirement including control joints of 4M X 4M
size and filling the panels with polyurethane sealant.
WET AREA (Kitcen, Toilets, Wash Area) : Surface Preparation: Providing and laying water proofing treatment to horizontal and vertical
surfaces of concrete, including cleaning the surface with wire brush, treating all surface cracks, construction joints and honeycombs
57 by grouting with specialised non shrink grout,coving preparation at wall - slab joint and preparation of surface in all aspects to receive the SQM 1,859.00 15.00
Injection Grouting (If required): Providing Chemical injection treatment in the form of pressure grouting to the cold joint by injecting
cement slurry mixed with grout admixture @ 250 gms.per bag of cement, in the required consistency through the pre fixed PVC nozzles in
the 10mm dia holes, fixing of PVC nozzles with quick setting compound and final cutting the projected nozzles and sealing off the PVC
nozzles after the injection operation is over with quick setting compound , no shrink rapid setting mortar compound, finishing, curing etc. as
per manufacturers specification and as directed. If any lekages found in preponding then this need to be done.
Coving: Providing and Applying at the junction of slab and vertical offsets with Cement Mortar 1:4 and admixed with SBR polymer at
dosage of 5Ltr per 50kg cement.
Waterproofing Coating-Providing and application of a two component, cementitious acrylic polymer based high performance water
proofing coating. It offers seamless coating applied@ 2 Kg /SQM for 2 coats @ 1.00 mm DFT .Technical Data: Inter coat application time,
Hrs 2-3, Tensile strength (ASTM D 412) >2 N/mm² , Elongation at break (ASTM D 412)
>175%, Adhesion strength (ASTM D 4541) >1.2 N/mm², Crack bridging (ASTM C 836) pass up to 2 mm.
Toilet Sunk Filling : (not applicable for toilets with underslung plumbing) :
Providing and filling sunken area with Light Weight Block bat (40-60 mm) with cement mortar mixed in ratio 1:3:6 (1 cement : 3 sand :
brick bats) including mixing of water proofing compound 4 % by weight of cement to sunk portions of toilets to the entire satisfaction of the
PM. Toilet / Sunk portion shall be tested by ponding water for 72 hrs.
WATER RETAINING STRUCTURES (UGT & OHT) : Surface Preparation: Providing and laying water proofing treatment to horizontal and
vertical surfaces of concrete, including cleaning the surface with wire brush, treating all surface cracks, construction joints and honeycombs
58 by grouting with specialised non shrink grout,coving preparation at wall - slab joint and preparation of surface in all aspects to receive the SQM 2,556.00 105.00
Item no. Item Description Unit Rate Total Qty. Amount
Injection Grouting (If required): Providing Chemical injection treatment in the form of pressure grouting to the cold joint by injecting
cement slurry mixed with grout admixture @ 250 gms.per bag of cement, in the required consistency through the pre fixed PVC nozzles in
the 10mm dia holes, fixing of PVC nozzles with quick setting compound and final cutting the projected nozzles and sealing off the PVC
nozzles after the injection operation is over with quick setting compound , no shrink rapid setting mortar compound, finishing, curing etc. as
per manufacturers specification and as directed.If any lekages found in pre ponding then this need to be done.
Coving: Providing and Applying at the junction of slab and vertical offsets with Cement Mortar 1:4 and admixed with SBR polymer at
dosage of 5Ltr per 50kg cement.
Protective Plaster: providing and laying avg. 15 mm thick, CM 1:4 plaster admixed with Integral Waterproofing Compound @ 150 ml / bag
of cement at Vertical Walls. Food Grade epoxy coating- Application of food grade epoxy coating in Inner side of tank: providing and
applying CFTRI Certified epoxy coating applied @ 0.600 kg/m2 in two coats. It will give 400 microns thickness. Pot life: 30 Minutes at 25°C
,20 Minutes at 30°C,Mixing Ratio, by Weight: 100(Base):38(Hardener), Touch dry: 4 Hours at 30ºC, Re coatable: 12 -18 Hours at 30ºC,
Open to foot traffic: 24 Hours at 30ºC, Final cure: 7 Days at 30ºC, Adhesive bond strength to concrete, (ASTM D 4541): >1.5 MPa (concrete
WATERPROOFING FOR PODIUM WITH HARDSCAPE : Surface Treatment: Providing and laying water proofing treatment of terrace
including cleaning the surface with wire brush, treating all surface cracks, construction joints and honeycombs by grouting with specialised
non shrink grout and preparation of surface in all aspects to receive the waterproofing.
Coving: Providing and Applying at the junction of slab and vertical offsets with Cement Mortar 1:4 and admixed with SBR polymer ReArm
Bond SBR 45 of MYK Arment or equivalent at dosage of 5Ltr per 50kg cement.
Application of primer: Providing and applying Epoxy based primer FloArm Primer PUDC of MYK Arment or equivalent over well prepared
surface at 200-400 gm per Sq.Mtr.
Application of Polyurethane waterproof coating: Providing and applying Two coats of liquid applied single component polyurethane based
waterproofing system AquaArm SPU-SPL of MYK Arment or equivalent . It has to be applied @1.95 kg/sqmtr to achieve a thickness of
1.2 mm in two coats.The membrane will have the following technical parameters: Tensile Strength : 2 N/mm2 ,. Elongation at break : 400%
, Adhesion To concrete: >1.5 N/mm2,
Providing and laying 150 Gsm Geo fabric membrane as separation layer
Protection Screed:Horizontal Areas: Providing and Laying M25 grade screed concrete in 1:100 to a average thickness of 100 mm mixed
with Integral Waterproofing admixture AquaArm Prufe IWP 10 of MYK Arment or equivalent at the dosage of 125 ml/bag of cement over
waterproofing layer to a minimum thickness of 75 mm as per site requirement(Civil Contractor Scope) including control joints of 4M X 4M
size and filling the panels with polyurethane sealant.
WATERPROOFING FOR PODIUM WITH SOFTSCAPE : Surface Treatment: Providing and laying water proofing treatment of podium
including cleaning the surface with wire brush, treating all surface cracks, construction joints and honeycombs by grouting with specialised
non shrink grout and preparation of surface in all aspects to receive the waterproofing.
Coving: Providing and Applying at the junction of slab and vertical offsets with Cement Mortar 1:4 and admixed with SBR polymer ReArm
Bond SBR 45 of MYK Arment or equivalent at dosage of 5Ltr per 50kg cement.
Application of primer: Providing and applying Epoxy based primer FloArm Primer PUDC of MYK Arment or equivalent over well prepared
surface at 200-400 gm per Sq.Mtr.
Application of Polyurethane waterproof coating: Providing and applying Two coats of liquid applied single component polyurethane based
waterproofing system AquaArm SPU-SPL of MYK Arment or equivalent . It has to be applied @1.95 kg/sqmtr to achieve a thickness of
1.2 mm in two coats.The membrane will have the following technical parameters: Tensile Strength : 2 N/mm2 ,. Elongation at break : 400%
, Adhesion To concrete: >1.5 N/mm2,
TOTAL AMOUNT WATER PROOFING WORK
TOTAL AMOUNT WATER PROOFING WORK
H DOOR AND WINDOW WORK
Item no. Item Description Unit Rate Total Qty. Amount
FLUSH DOOR (SINGLE / DOUBLE LEAF) WITHOUT HARDWARE WITHOUT LOUVERS : Providing and fixing 35 mm thick pre-
laminated (1mm) hinged door made out of 150mm x 70mm cp-sag indian teak wood outer frame with holdfast and shutters made of
mm thick facory fabricated flush door including concealed lipping (35mmx6mm-matt malamine polished to exposed surface) to receive
61 hinges. colour and shade for laminates shall be as architect. All necessaty carpentery and civil work to fix in true line & level, plumb at all SQM 5,233.00
level shall be part of contractor and commissioned as directed by EIC. Hardware shall be paid extra under relavent item. It is inclusive of
matt melamine polish (1 coat sealer + minimum 2 coat matt mellamine polish) with sanding, rubbing, etc. complete
For single / double leaf shutter without hardwares without louvers
FLUSH DOOR (SINGLE LEAF) WITHOUT HARDWARE WITH LOUVERS : Providing and fixing 35 mm thick pre-laminated (1mm) hinged
door made out of 150mm x 70mm cp-sag inidan teak wood outer frame with holdfast and shutters made of 35 mm thick facory fabricated
flush door including concealed lipping (35mmx6mm-matt malamine polished to exposed surface) to receive hinges. colour and shade for
62 laminates shall be as architect. All necessaty carpentery and civil work to fix in true line & level, plumb at all level shall be part of contractor SQM 5,644.00
and commissioned as directed by EIC. Hardware shall be paid extra under relavent item. It is inclusive of matt melamine polish (1 coat
sealer + minimum 2 coat matt mellamine polish) with sanding, rubbing, etc. complete
Do as above for single leaf with louvers without hardwares
HARDWARE FOR DOORS :
HINGE FOR ALL FLUSH DOORS : dormakaba 3043F, 5 Knuckle, 2 Ball bearing butt hinges size 4" x 3" x 3mm, Material: SS 304, Finish:
63 Satin Stainless Steel (SSS). Suitable for Wooden door weight up to 120kgs, Grade 13, Template Drilled. Approved to EN 1935, Fire-rated, Nos.. 273.00
Square Corners, Durability - 200,000 Cycles, Corrosion Resistance - Very High
MORTICE SASH LOCK FOR REGULAR DOORS : dormakaba Mortice sash lock 271a with 55mm backset, 20mm square forend with
64 mm centers and prepared for euro profile cylinder including strike plate in satin stainless steel as per EN 12209, Durability - 200,000 Cycles, Nos.. 1,599.00
Load on Latch Bolt - 50N , Door mass - 200 kg, Corrosive resistance - Very High ( - 20 C to +80 C)
MORTICE SASH LOCK FOR TOI. DOORS : dormakaba Mortice WC lock 275a with 55mm backset, 20mm square forend with 78 mm
65 centers and prepared for 8mm bathroom follower including strike plate in satin stainless steel as per EN 12209, Durability - 200,000 Nos.. 1,598.00
Cycles, Load on Latch Bolt - 50N , Door mass - 200 kg, Corrosive resistance - Very High ( - 20 C to +80 C)
MORTICE DEAD LOCK : dormakaba Mortice dead lock 278a with 55mm backset, 20mm square forend, prepared for euro profile cylinder
66 including strike plate in satin stainless steel as per EN 12209, Durability - 200,000 Cycles, Load on Latch Bolt - 50N , Door mass - 200 kg, Nos.. 1,581.00
Corrosive resistance - Very High ( - 20 C to +80 C)
LOCK PROFILE FOR DEAD LOCK : dormakaba Mortice dead lock 278a with 55mm backset, 20mm square forend, prepared for euro
67 profile cylinder including strike plate in satin stainless steel as per EN 12209, Durability - 200,000 Cycles, Load on Latch Bolt - 50N , Door Nos.. 459.00
mass - 200 kg, Corrosive resistance - Very High ( - 20 C to +80 C)
EURO PROFILE CYLINDER - BSK (Both Side Key) : dormakaba DEC 6 Plus 60, 6 pin Euro profile cylinder with inline brass keys. Master
68 keyed system included as per client requirement. Nos.. 1,997.00
External & Internal key operation. Length: 60mm
EURO PROFILE CYLINDER - KT (Key + Thumbturn) : dormakaba DEC 6 Plus 60T, 6 pin Euro profile cylinder with inline brass keys.
69 Master keyed system included as per client requirement. Nos.. 2,168.00
External key & Internal thumb turn operation. Length: 60mm
EURO PROFILE CYLINDER - CT (Coin + Thumbturn) for Toilets : dormakaba 3016, 6 pin Euro profile knob cylinder with internal thumb
turn and external coin operation standard length 60mm in satin nickle plated finish. NMK.Durability: 100,000 Cycles
LEVER HANDLE (PAIR): dormakaba Pure Lever handle 8906 lever with round roses, escutcheons prepared for Euro profile cylinder and
71 spindle 114 in satin stainless steel. Complete set including the fixing accessories for 50mm thick door. Material:SS 304. Approved to EN Nos.. 2,639.00
1906 , Durability - 200,000 Cycles, Corrosion Resistance - Very High
LEVER HANDLE WITH INDICATOR (PAIR): dormakaba Pure 8906 Lever Handle with 6501 Roses,7122 WC Indicator, 8mm Spindle with
Fixing Screws for door thickness 35-55mm, SS 304, Finish : Satin
73 TOWER BOLT : dormakaba 3200-2 Surface Mounted Tower bolt of Length 6" in Satin chrome finish Nos.. 474.00
74 PEEP HOLE : 180° brass/SS, dormakaba equivalent Nos.. 748.00
Item no. Item Description Unit Rate Total Qty. Amount
DOOR CLOSER : dormakaba rack and pinion door closer TS 68 with selectable closing force, size EN 2, 3 and 4 , std. arm adjustable
75 closing speed in two independent ranges. Non-handed. Approved to EN 1154. Durability - 500,000 Cycles ,Corrosive resistance - Moderate, Nos.. 3,308.00
PULL HANDLE (PAIR) : dormakaba pull Handle TGDI-D 300 back to back with adjustable fixing for glass, wood and metal doors in satin
76 stainless steel. The pull handles should have supporting washer with raised bevelling on the outer surface.CTC - 300mm, 22mm dia, Nos.. 1,922.00
Material - SS304
DEAD BOLT FOR SHAFT FLUSH DOORS : dormakaba Mortice shaft dead bolt with key with BS 57mm and 25mm Sq forend with
escutheions in SSS.
78 OVAL PULL HANDLE FOR SHAFT FLUSH DOORS : dormakaba Recessed Oval Flush Pull Handle 1207, SSS Nos.. 434.00
HARDWARE FOR ADA TOILET DOOR :
ADA TOILET DOOR - HINGES : dormakaba 3043F NRP, 5 Knuckle, 2 Ball bearing butt hinges size 4" x 3" x 3mm with Non-Removable
Pin, Material: SS 304, Finish: Satin Stainless Steel (SSS). Suitable for Wooden door weight up to 120kgs, Grade 13, Template Drilled.
79 Approved to EN 1935, Fire-rated, Square Corners, Durability - 200,000 Cycles, Corrosion Resistance - Very High Nos.. 401.00
ADA TOILET DOOR - DOOR CLOSER : dormakaba TS 92 B barrier free access designed cam action door closer complying to BS 8300 &
ADM opening force of below 30N between 0º and 30º degrees and below 22.5N between 30º and 60º degrees. Complies to CEN
Guidelines of 40% reduced opening force & minimum 65% door closer efficiency. Door closer with G-N slide channel arm for pull side
80 fixing, adjustable closing speed in two independent ranges. closing force infinitely variable between size EN 1 and EN 4. Non-handed. Nos.. 17,345.00
Approved to EN 1154 and CERTIFIRE, CE Marked. Durability - 500,000 Cycles, Corrosive Resistance - High. Finish: Silver
ADA TOILET DOOR - LOCK : dormakaba Mortice WC lock 375a with 55mm backset, 20mm square forend with 78 mm centers and
81 prepared for 8mm bathroom follower including strike plate in satin stainless steel as per EN 12209, Durability - 200,000 Cycles, Load on Nos.. 1,852.00
Latch Bolt - 120N , Door mass - 200 kg, Corrosive resistance - Very High ( - 20 C to +80 C)
ADA TOILET - LEVER WITH INDICATOR : dormakaba Pure Lever handle 8100 lever with round roses, 7122 WC Indicator and spindle
114 in satin stainless steel. Complete set with fixing accessories for 50mm thick door. Approved to EN 1906, Durability - 200,000 Cycles,
82 Corrosion Resistance - Very High Nos.. 3,084.00
ADA TOILET DOOR - GRAB BAR : dormakaba GBDI D-600 Grab Bar of Length 610mm, 25mm Diameter in Satin stainless Steel Finish.
METAL DOORS - FIRE RATED (120 Mins) -
METAL FIRE DOORS (120 Minutes) with 30 min insulation As per IS3614:
Supply and fixing of Hollow metal fire rated doors as per IS 3614:2021 for stability and integrity with 30minutes insulation. Pressed
Galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall have doors tested at CBRI /NABL
Approved Labs for maximum rating of 2hrs tested . Individual Test certificates should also be available for glass used in vision lites
confirming the required fire ratings /panels being a part of the fire door assembly. Doors should be finished in Thermosetting Powder
84 Coating desired RAL Shades. Manufacturer test certificate shall cover doors both single & double leaf doors and Hardware's should pass SQM 5,520.00
European certificate "CE" of conformity / UL with required fire ratings. Any deviation in specification and sheet thickness other than what is
mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Approved
manufacturer Navair International or equivalent subject to architect’s approval. And should be ISO Certified company.
Item no. Item Description Unit Rate Total Qty. Amount
Door frame shall be Single rebate profile of section 100 x 57 mm made out of 1.60mm thick galvanised steel sheet with a factory pre-
punched groove so as to accomodate Fire & smoke seal size 10x4mm . Frames should be butt jointed and field assembled with bolting
system for proper strength .Frames should be provided with back plate for anchor fasteners (payable extra ) for installation on a finished
plastered wall opening.
Door leaf shall be minimum 46mm thick fully flush double skin door with or without vision lite. Door leaf shall be manufactured from 1.2mm
minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate
hardware. The infill material shall be Rockwool treated with Viper FRS 881 LH. All doors shall be factory prepared for receiving appropriate
hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending
radius of 1.4mm. For pair of doors astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever
applicable should be provided as per manufacturers recommendation with a beading and screws from inside.
All doors and frames shall be finished with Powder coating in desired Shades. Once frame installed should be filled with PUF as
recomended by the manufacturer or engineer.
HARDWARE FOR METAL DOORS
85 SS Ball Bearing Hinges of size 100 x 75x 3mm complete with SS Screws of Becker fs make ( 4 Nos. per panel ) Nos.. 253.00
86 Door closer overhead STD arm Becker fs make Nos.. 2,553.00
87 Fire glass 6MM Thick 200x300mm Vision Glass from Saint Gobain Nos.. 2,128.00
88 Mortise dead lock with both side key cylinder Becker fs make Nos.. 2,502.00
89 SS Pull handle 300 mm long back to back D type Becker fs make Nos.. 1,909.00
90 Fire seal 10x4mm & smoke seal RMT 299.00
91 Hilti fasteners 10X 80mm Nos.. 64.00
92 Concealed flush bolt 600mm long for double door Becker fs make Nos.. 1,403.00
93 Frameless "U" Channel glazing (INTERNAL FIXED GLAZING) SQM 4,370.00
Design, Fabrication, Supply, Installation, Protection, Cleaning & Handover of Frameless glazing system with Aluminium "U" Channel custom
designed to with stand the design wind pressure confirming to IS -875 part III. (The system must pass the proof test at 2 times design wind
pressure without any failure).
The system shall be support the glass at bottom and wind resistance at top by means of continuous U-channel at the finished floor level and
vertically butt glazed with non staining sealant joint between glass to glass. The weather sealant of approved make, baker rod, SS
grade fasteners & hard setting blocks of EPDM, all in complete required to perform as per specification and drawing in conjunction with
BOQ. Complete system shall be warranted for minimum 10 yrs against design & workmanship defects.
The extruded aluminium sections of Alloy 6063 T5 / T6 & tolerances confirming to DIN / EN standard from approved extruder. All the visible
surfaces shall have high Durability (Akzonobel) / Super durable (Jotun) Powder coating of 60 - 80 micron.
All Material Make / Vendor list / Supplier list shall be as per tender specification.
All shade approval shall be as per Architect's Approval.
The quote rate shall include all design, engineering & Approval from architect & consultant.
Quote rate for complete system as mentioned above under (B) U-Channel Design in line with Tender drawings for Ground Floor and First
Floor Retail Area, Providing & Fixing Façade 12mm Clear FT Glass.
Frameless Swing Doors_ (Patch Fitting Doors)
Design, Fabrication, Supply, Installation, Protection, Cleaning & Handover Single & Double leaf double swing patch fitting door made out
12mm thick fully tempered (FT) glass with Dorma make stainless steel patch fittings for external facade application (PT Series ). Complete
with 38mm dia SS handle 1000mm long , PT series patch fittings, US 10 Door lock at bottom of each shutter and BTS 80, 90 deg with EN 1-
4 spring capacity floor spring. Floor spring covers shall be SS satin finish. as per Architect's approved shop drawings.
Door glass of 12 mm thk clear float fully tempered with holes and notches as per patch fitting requirement. Edges Machine ground mirror
polished. The door glass shall have silicon gasket at bottom to act as weather seal.
All Material Make / Vendor list / Supplier list shall be as per tender specification.
The quote rate shall include all design & shop drawing approval from architect & consultant.
Quote rate for complete system for Frame Less Patch Fitted Door as mentioned above under (C)
Item no. Item Description Unit Rate Total Qty. Amount
94 1 - Double Leaf Swing Door:- (Size:- 1500mm x 2100mm) with 12mm Thk. Clear FT Glass. Location:- First floor Internal Portion. Nos.. 80,500.00
95 2 - Single Leaf Swing Door:- (Size:- 1000mm x 2100mm) with 12mm Thk. Clear FT Glass. Location:- First floor Internal Portion. Nos.. 40,250.00
Aluminium Louvers ( "Y" Type Louvers) System_
Vantilation Lover system - BUILDING FAÇADE AT SHAFTS LOCATION
Design, Fabrication, Supply, Installation, Protection, Cleaning & Handover of Aluminium " Y " shape Louvers System custom designed to
with stand the design wind pressure confirming to IS -875 part III.
Aluminium Louvers shall be made out of 60mm x 36mm x 1.5mm thk. of " Y " shape louvers system spaced at equivalent distance support
to Aluminium frame. Louvers profile shall be fixed on the 3mm thick Al flat to form a frame. The louver frame is supported on the
aluminium box frame with necessary fasteners in SS 316 in line with tender drawing
The extruded aluminium sections of Alloy 6063 T5 / T6 & tolerances confirming to DIN / EN standard from approved extruder. The
structural profiles shall have minimum 2 mm wall thickness. All the internal & External visible surfaces shall have Super Durable Powder
coating finish of 60-80 micron thickness as per Approved shade by Architect. The non visible aluminium surfaces shall have mill Finish.
All Material Make / Vendor list / Supplier list shall be as per tender specification.
All shade approval shall be as per Architect's Approval.
The quote rate shall include all design & shop drawing approval from architect & consultant.
Quote rate for complete Aluminium "Y" Type Louvers system as mentioned above under (F)
Aluminium "Y" Type Louvers system_Vantilation Louver System, Location:- Staff Qtrs exterior face shafts
Sliding Window - 4 track : Providing and fixing extruded aluminum window having extruded aluminum Colour Powder Coated section
frame main outer size 127mm x 38.10mm x 1.35mm ,@ Wt.1.384 Kg/mt,horizontal Four track member size 122.20mm x 31.75mm x
1.10mm @ Wt. 1.205 Kg/mt,vertical member of size 122.20mm x 31.75mm x 1.50mm ,@ Wt. 1.398 Kg/mt with sliding shutters of horizontal
97 member size 40mm x 18mm x 1.29mm @ wt.of 0.456Kg/mt,vertical member of size 40mm x 18mm x 1.29mm @ wt.of 0.456Kg/mt,@ with 5 SQM 2,119.14
mm thick transparent bronze colour tinted float glass with powder coated aluminum fittings and fixtures and transparent silicon sealant glass
fixing to frame as per details etc complete for window.
Sliding Window - 3 track : Providing and fixing window having extruded aluminum Colour Powder Coated section frame main outer size
95mm x 24mm x 1.17mm @ wt.of 0.738 Kg/mt, horizontal Three track member size 92mm x 31.75mm x 1.30mm @ Wt.1.07 Kg/mt, vertical
member of size 92mm x 31.75mm x 1.50mm ,@ Wt. 1.06 Kg/mt with sliding shutters of horizontal member size 40 mmx18mm x1.29mm @
98 wt.of 0.456 Kg/mt, vertical member of size 40mm x 18mm x 1.29 mm @ wt.of 0.456Kg/mt with 5 mm thick transparent bronze colour tinted SQM 1,576.11
float glass with powder coated aluminum fittings and fixtures and transparent silicon sealant glass fixing to frame as per details etc
Sliding Window - 2 track : Providing and fixing window having extruded aluminum Colour Powder Coated section frame main outer size
63.50 x 38.10 x 1.95 mm,@ Wt 1.094 Kg / Rmt, horizontal two track member size 1.85 mm x 31.75 mm x 1.20mm @ wt.of 0.695 Kg/mt,
vertical member of size 61.85 mm x 31.75mm x 1.30 mm @ wt.of 0.0.659 Kg/mt with sliding shutters of horizontal member size 40mm x
99 18mm x 1.29mm @ wt.of 0.456Kg/mt, vertical member of size 40mm x 18mm x 1.29mm @ wt.of 0.456Kg/mt with 5 mm thick transparent SQM 1,688.78
bronze colour tinted float glass with powder coated aluminum fittings and fixtures and transparent silicon sealant glass fixing to frame as per
details etc complete for window
VENTILATION : Design, Fabrication, Installation, Protection, Cleaning and Handover of Alum. Glass Louver windows with exhaust Fan
fixing Provision in Toilet areas with hardware's and accessories.
The extruded aluminium sections of Alloy 6063 T5 / T6 & tolerances confirming to DIN / EN standard from approved extruder. All the
internal visible surfaces shall have high Durability (AkzoNobel) / Super durable (Jotun) Powder coating of 60 - 80 micron confirming to
AAMA 26043. The non visible aluminium surfaces shall have minimum chromatizing treatment.
All Material Make / Vendor list / Supplier list shall be as per tender specification.
All shade approval shall be as per Architect's Approval.
The quote rate shall include all design & shop drawing approval from architect & consultant.
Quote rate for complete Glass Louvers system as mentioned above under :
Ventilation Windows (V1) Bottom Glass Louvers With Top Fix :-
Top Fix:- 6mm Thk. Frit Glass SQM 3,422.00
Item no. Item Description Unit Rate Total Qty. Amount
Glass Louvers:- 5mm Thk. Frit Glass @30mm C/C SQM 3,422.00
ALUMINIUM FIXED WINDOW / Top/side HUNG OPENABLE (OUT) :
Design, Fabrication,Supply,All Material & Site Testing, Protection, Handover of Alum. Fix / Top/Side Hung openable windows system
101 custom designed to with stand the design wind pressure confirming to IS -875 part III. The system shall have two barrier gasket system for
weather sealing. Provision for drainage of uncontrolled water entering to 1st barrier gasket.
Top/Side hung openable window system shall be including malti-point locking (Min.two) with Handle, projected type hinges with restrictor
arm of approved make, Microwave cured EPDM gaskets. window shutter profile to accommodate the 6mm SGU HS glass, weather
sealants, SS 316 grade screws and fasteners of approved make, all in complete required to perform as per specification and drawing in
conjunction with BOQ.
The extruded aluminium sections of Alloy 6063 T5 / T6 & tolerances confirming to DIN / EN standard from approved extruder. All the
internal visible surfaces shall have high Durability (AkzoNobel) / Super durable (Jotun) Powder coating of 60 - 80 micron confirming to
AAMA 26043. The non visible aluminium surfaces shall have minimum chromatizing treatment.
All Material Make / Vendor list / Supplier list shall be as per tender specification.
All shade approval shall be as per Architect's Approval.
The quote rate shall include all design & shop drawing approval from architect & consultant.
Quote rate for complete Aluminium Windows system as mentioned above under (F) With 6mm Thk. HS Glass in line with tender
Providing and fixing a Top/Side Hung Openable vent With 6mm Thk. HS Glass . 6,182.00
Providing and fixing a Fix Windows With 6mm Thk. HS Glass. 5,089.00
Providing and fixing rolling shutters of approved make made of 80 mm wide M.S. laths inter-locked together through their entire length and
jointed together at the ends by end locks mounted on specially designed pipe shaft with bracket plates, guide channels and arragements for
102 inside and outside locking with push-pull operation including the cost of hood cover and spring etc. complete. (B) Shutters having width 3.5 SQM 3,468.72
103 Providing and fixing 27.5 cm. long wire spring grade No.2 of approved make for rolling shutters. EACH 630.91
104 Providing and fixing Hood cover for rolling shutters (B) Shutters having width 3.5 meters and above RMT 120.03
TOTAL AMOUNT DOOR & WINDOWS
TOTAL AMOUNT DOOR & WINDOWS
I MISCELLENEOUS
Pre construction Anti termite Treatment : Providing and injecting pre-constructional anti-termite treatment as per IS:6313 (Part-II) to the
RCC members in immediate contact with soil upto a min depth of 500 mm measured from made up ground level by treating all four sides at
the rate of 7 Lit/Sqm of an emulsion in water of 0.5 % Chloripyrofos 20 EC or equivalent, treating the top surface of plinth filling and the
external peripheri of the building by drilling the holes up to 75 mm deep at 150 mm c/c distance bothways using 12 mm dia ms rod on the
105 surface to facilitate saturation of the soil with the chemical emulsion at the rate of 5 Lit/Sqm of surface area of an emulsion in water of 0.5 % SQM 384.00
Chloripyrofos 20 EC or equivalent. The contractor shall furnish 10 years guarantee for termite free structure. (Plan area at ground floor level
shall be measured for payment.)Notes:1) Allow for Min. of 10 years gaurantee as described under detailed specifications. 2) Only single
time Plinth area shall be measured for payment, deducting open to sky shafts,verandah etc. for all kinds of buildings i.e. building having
basements or no basements.
Providing and fixing 6mm thick frameless mirror of approve make in any shape and sizes as per drawing. Mirror shall be fixed on 12mm
thick marine plywood backing. Marine plywood shall be fixed to wall with approved SS 304 fastener. All edges of glass shall be sharp
grinded, cut corner and polished. Glass shall be fixed with approved adhesive/ 3M tape etc. complete at all floors/ all levels/ all heights as
106 directed by Engineer In Charge. Installed area of mirror shall be considered for payment without wastage.Structural steel work ( Confirming SQM 5,897.00
to IS 4923-1997) riveted, bolted or welded in builtup for all type sections, in framed work, including cutting, hoisting, fixing in position and
applying a priming coat of approved steel primer all complete as per the structural designs and directions of Engineer in charge.
Item no. Item Description Unit Rate Total Qty. Amount
Providing, fabricating, assembling, hoisting/ erecting and fixing for structural steel work in position at all heights/ all levels/ all floors/ all
shapes & sizes with all leads & lifts using MS Rolled Steel Sections, Hollow sections, Tubular Sections, MS Plates, Chequered Plates, MS
Pipes, Perforated Sheet, Flats, Bright Bars, Angles, MS Sheet, Girder, Beam, cattle trap. deep threaded MS bolts, threaded J bolts, insert
plate, support plate etc as per drawing. all confirming to latest relevant IS codes for the work of steel structures like gratings over drain
channel, I beams, staircases, railings, handrail, jali, gates, grills, bracings, platforms, brackets, monkey ladder, cattle trap, windows, pipe
rack, rungs, false ceiling frame work, Roof canopy, fencing posts, M.S. Screen & fencing jali frame work etc. including straightening, cutting,
bending, bolting and welding the members all as per structural drawings and as per detailed specifications (for materials & workmanship)
including necessary scaffolding/ staging etc. complete in the situations described hereinafter and comprising of : i) Profile Cutting of
components to required length/ width and shape/ profile; ii) Smooth grinding/ machining of edges/ faces/ all welding joints; iii) Necessary
welding (electric arc welding) for required weld lengths and sizes. (non structural elements) iv) Machine drilling of holes for joining/
107 anchoring (Standard measurements will be paid for as actual cut length used at site). KG 126.68 14,573.00
Note: The contractor shall be submit fabrication drawings based on construction drawings (that may be issued during construction period
with at least one mock up approved by architecture ) for approval by the Architect/ Engineer. The fabrication work shall start only after
approval of the fabrication drawings submited by contractor. Any change required in the fabrication drawings shall be carried out at No extra
cost. Fabrication shall be in a perfect architectural workmanship manner and as provided in section V & VI of IS 800 & IS 7215. Welding
shall be carried out by qualified welders/ fabricators.It should also include the cost of necessary scaffolding/ staging, zinc coated nut-bolt as
required for safety, structural stability of all works at site.
Extra on STRUCTURAL STEEL item - for all kinds of sleeves in hydraulic structure Hot dip Galvanised with minimum 65microne thick (only
difference shall be paid instead of 2 coat zinc chromate yellow oxide and 2 coat of enamel paint)
Providing and fixing G.I. chain link fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts,
109 bolts and washers as required complete as per the direction of Engineer-in-charge. SQM 3,393.00
Made of G.I. wire of dia 4 mm
Providing and wet drilling accurate and clean holes of 25‐400 mm range without vibration through Hilti diamond drilling machine DD200
having 1:1 & 1:3 gearing ratio for wide range of reinforcements in concrete, control panel indicator to display proper pressure application,
110 capable of drilling at angle from 0o‐ 45o and do overhead application. Before coring rebar loaction to be identifed with Hilti PS
(ferroscanner) tool or equvivalent.
25 mm dia RMT 11,615.00
37 mm dia RMT 13,938.00
52 mm dia RMT 14,867.20
77 mm dia RMT 17,190.20
102 mm dia RMT 18,584.00
127 mm dia RMT 22,300.80
152 mm dia RMT 25,553.00
202 mm dia RMT 34,845.00
252 mm dia RMT 46,460.00
300 mm dia RMT 75,498.00
TOTAL AMOUNT MISCELLENEOUS
TOTAL AMOUNT MISCELLENEOUS
J FURNITURE WORK
Item no. Item Description Unit Rate Total Qty. Amount
Providing And Supply High Back Rev. Chair Upholstered with Leatherette Seat Made Up Of 12mm +/- 1mm Thick Hot Pressed Mr. Grad
Plywood and Back in Two Pieces - 12mm Rear Back And 6mm Inner Back. Moulden Polyurethane Foam Used in Making Seat with Molded
Density 45+/- 2 Kg/M ³. Back Is Made Out Of 32 Density Block Foam Covered With 14mm Thick 32 Density Foam Sheet (Block Foam).
Spine Bracket Made Of M.S Plate 8mm Thickness Connecting Back with Mechanism. Armrest Top Is Soft Touch Polyurethane Molded Of
250 To 300 Density Insert Stainless Steel Pipe Having Unique " Y "Shape. The Mechanism of the Chair Have Following Features: 360⁰
Revolving Type 3.5Mm Thk Crca Seat Plate With 4Mm Thk Crca Channel Plate Synchro Mechanism, Tilt Tension Adjustable, Single
Position Locking, Plastic Component Inside the Mechanism of Grade - Mi 3530 And Epoxy Powder Coated 70 Microns with Tested 1.2 Lacs
111 Cycles as Per Bifma Standard. The Chair Provided with Pneumatic Height Adjustment Which Have Have Stroke Of 100mm +/- 5mm.The Nos. 19,078.00
Five Leg Base Is Made Up Of 38Mm Dia X 1.2Mm Thick Tubular With 3.15mm Thick Centre Hub Crc Fabricated Chrome Finish. It Have Be
Fitted With 50mm Dia Twin Wheel Castor . The Size of The Base Have Be - 660 +/- 1mm Pitch-Centre-Diameter. Load Test As Per Bifma
Compliance. The Twin Wheel Castors Made Of Nylon Injection Molded In Black Color. Overall Dimensions Of Chair Have Be, Width Of
Chair - 640mm, Depth Of Chair 640mm As Measured From Base Below. Height Of Back From Ground - Min 1175 To Max 1275mm. Seat
Height -Min 480mm To Max 580mm. Dimensions Tolerance / Variations Have Be Within +/- 10mm.
Providing And Supply Med. Back Rev. Chair Upholstered With Leatherette Seat Made Up Of 12mm +/- 1mm Thick Hot Pressed Mr Grad
Plywood And Back In Two Pieces - 12mm Rear Back And 6mm Inner Back. Moulded Polyurethane Foam Used In Making Seat With
Moulded Density 45+/- 2 Kg/M ³. Back Is Made Out Of 32 Density Block Foam Covered With 14mm Thick 32 Density Foam Sheet (Block
Foam).Spine Bracket Made Of M.S Plate 8mm Thickness Connecting Back With Mechanism. Armrest Top Is Soft Touch Polyurethane
Moulded Of 250 To 300 Density Insert In Stainless Steel Pipe Having Unique " Y "Shape. The Mechanism Of The Chair Have Following
Features: 360⁰ Revolving Type 3.5Mm Thk Crca Seat Plate With 4Mm Thk Crca Channel Plate Synchro Mechanism, Tilt Tension
Adjustable, Single Position Locking , Plastic Component Inside The Mechanism Of Grade - Mi 3530 And Epoxy Powder Coated 70 Microns
112 With Tested 1.2 Lacs Cycles As Per Bifma Standard The Chair Provided With Pneumatic Height Adjustment Which Have Have Stroke Of Nos. 23,265.00
100mm +/- 5mm.The Five Leg Base Is Made Up Of 38Mm Dia X 1.2Mm Thick Tubular With 3.15mm Thick Centre Hub Crc Fabricated
Chrome Finish. It Have Be Fitted With 50mm Dia Twin Wheel Castor . The Size Of The Base Have Be - 660 +/- 1mm Pitch-Centre-
Diameter. Load Test As Per Bifma Compliance.The Twin Wheel Castors Have Be Made Of Nylon Injection Moulded In Black Colour.Overall
Dimensions Of Chair Have Be, Width Of Chair - 630mm, Depth Of Chair 630mm As Measured From Base Below. Height Of Back From
Ground - Min 950 To Max 1050mm. Seat Height -Min 470mm To Max 570mm. Dimensions Tolerance / Variations Have Be Within +/-
Providing and supply Seat and back in single piece with integrated arms like bucket shape, nylon moulded of 450 to 500 density fix inner
and outer snap fit arrangement in back with mesh fabric inside on equal interval of rectangular slots design. The mechanism of the chair
have have following features : 360⁰ revolving type, 2.5mm thk CRCA powder coated center tilt Mechanism, Tilt tension adjustment, locking
in single position, Plastic component inside the mechanism of Grade - MI 3530 and Epoxy Powder coated 70 Microns with tested 1.2 lacs
113 cycles as per BIFMA Standard The chair have be provided with pneumatic height adjustment which have have stroke of 100 +/- 5 mm. The Nos. 13,197.00
Base have be made of injection moulded nylon. It have be fitted with 5 Nos.. twin wheel castor - 50 mm diameter. The size of the base be
660 +/- 1 mm pitch-centre-diameter. The twin wheel castors have be made of Nylon injection moulded in black colour.
Providing And Supply Med. Back Rev. Chair Upholstered With Leatherette Seat Made Up Of 12mm +/- 1mm Thick Hot Pressed Mr Grad
Plywood And Back In Two Pieces - 12mm Rear Back And 6mm Inner Back. Moulded Polyurethane Foam Used In Making Seat With
Moulded Density 45+/- 2 Kg/M ³. Back Is Made Out Of 32 Density Block Foam Covered With 14mm Thick 32 Density Foam Sheet (Block
Foam). Armrest Top Is Soft Touch Polyurethane Moulded Of 250 To 300 Density Insert In Chrome Finish Pipe Having Unique "Bird
114 Beak"Shape.. Pipe structure of MS CRCA finish 16 gauge round pipe having a diameter of 25 mm with epoxy powder coated. Overall Nos. 17,498.00
Dimensions Of Chair Have Be, Width Of Chair - 630mm, Depth Of Chair 630mm As Measured From Base Below. Height Of Back From
Ground - Min 950 To Max 1050mm. Seat Height -Min 470mm To Max 570mm. Dimensions Tolerance / Variations Have Be Within +/-
Item no. Item Description Unit Rate Total Qty. Amount
Type: 2 Seater Sofa
Size (approx. Over all dimension): 1500mm(W) x 800mm(D) x 780mm (H) Top: Upholstery with Latherite Finish all visible surfaces
Specifications:Providing and supply Sofa sturcture made from 18mm MR Grade Mr grad plywood supported with Maranti Solid wood, back
side and curved part Covered with 3mm flexi ply, sofa arm made from 12mm thick MR Grade Mr grad plywood supported with maranti solid
wood. Elastic Belt, 75mm board & 2.25 mm thick elastic webbing stapling in seat frame at 100 mm centre to centre distance, belt fastern in
X and Y axies of seat, elastic belt elongation 45% tensile strength 350 kg. Foam 100 mm X 40 density Premium Quality foam covered with
25mm X 32 density super soft Premium Quality Foam for soft touch filling in seat. 50 mm X 40 density Premium Quality foam covered with
25mm X 32 density super soft Premium Quality foam for soft touch filling in back. Stiching Stiching work done with well known german
brand (Aman / Gutermann) Thread. Nylone & Polyster thread used as per application. Leg made from Stainless steel 316 Grade. all
material selection will be as per architect's selection, etc all complete with respect to necessary hardware and finishes
Type: 3 Seater Sofa Size (approx. Over all dimension): 2100mm(W) x 800mm(D) x 780mm (H) Top: Upholstery with Latherite Finish all
visible surfaces Specifications:Providing and supply Sofa sturcture made from 18mm MR Grade Mr grad plywood supported with Maranti
Solid wood, back side and curved part Covered with 3mm flexi ply, sofa arm made from 12mm thick MR Grade Mr grad plywood supported
with maranti solid wood. Elastic Belt, 75mm board & 2.25 mm thick elastic webbing stapling in seat frame at 100 mm centre to centre
distance, belt fastern in X and Y axies of seat, elastic belt elongation 45% tensile strength 350 kg. Foam 100 mm X 40 density Premium
116 Quality foam covered with 25mm X 32 density super soft Premium Quality Foam for soft touch filling in seat. 50 mm X 40 density Premium Nos. 91,123.00
Quality foam covered with 25mm X 32 density super soft Premium Quality foam for soft touch filling in back. Stiching Stiching work done
with well known german brand (Aman / Gutermann) Thread. Nylone & Polyster thread used as per application. Leg made from Stainless
steel 316 Grade. all material selection will be as per architect's selection, etc all complete with respect to necessary hardware and finishes
CENTER TABLE SIZE:-1100 x 600 & 450mm height
Providing fixing and arranging Center Table Providing and supply Top 20 mm thick made of PLY with 1 mm thick laminate finish with 2 mm
117 thick PVC edge bidding matching with same laminate finish. Nos. 26,393.00
STRUCTURAL SUPPORT SYSTEM:- shall be constructed using 40 x 40 mm matt finish S.S. Metal frame legs as per image. Entire table to
be finished with all necessary hardware and selection of material as per architect.
SIDE TABLE SIZE:-500 x 500 & 450mm height
Providing fixing and arranging Center Table Providing and supply Top 20 mm thick made of PLY with 1 mm thick laminate finish with 2 mm
118 thick PVC edge bidding matching with same laminate finish. Nos. 13,685.00
STRUCTURAL SUPPORT SYSTEM:- shall be constructed using 40 x 40 mm matt finish S.S. Metal frame legs as per image. Entire table to
be finished with all necessary hardware and selection of material as per architect.
"C" shaped table overall dimension 2250x1800x2700mm & 750mm height with 36 MM thick nail curvica post forming edges made of 17mm
OSR MDF with curvica laminate finish both long edges with ends having matching 2mm pvc edge band / beading, bottom surface to be
finished with balancer white. Provision to be given for snake / vertebrae from floor to wire manager for pop up box with switches and
sockets as per detail design and drawings. Fixed Drawer Unit Outer body 17mm thick MDF with curvica Laminate Finish. three drawers with
bullNos.e front with lock and necessary hardware. Side Table : Size as per drawings, Top and leg 36 MM thick nail curvica post forming
edges made of 17mm OSR MDF with curvica laminate finish both long edges with ends having matching 2mm pvc edge band / beading.
shutter 17mm thick OSR MDF with curvica Laminate Finish bullNos.e curvica laminate finish with lock and necessary hardware. Back Unit
size as per drawing Top and leg 36 MM thick nail curvica post forming edges made of 17mm OSR MDF with curvica laminate finish both
long edges with ends having matching 2mm pvc edge band / beading. shutter 17mm thick OSR MDF with curvica Laminate Finish bullNos.e
curvica laminate finish with lock and necessary hardware. Entire table to be finished with all necessary hardware. There will be provision of
footrest of size 750 x 400 x 150mm & storage top side and back unit top having a ledge of 150mm x 100mm boxing as shown in image
included in it. All hardware should be concealed & not visible. All handles should be concealed with SS finish.
Item no. Item Description Unit Rate Total Qty. Amount
Product : Collaborate Loop Leg Design
Dimensions : 1200mmL x 600mmD x 750mmHT Table top + 350mmHT Screen
Table Top: 25mm thick Pre laminate particle board with 2mm PVC edge lipping on all exposed edges
Support: End Legs: MS powder coated Collaborate Loop legs
Intermediate Legs: MS podwer coated 60X40mm legs and supporting MS cross beams (40X20mm)
Main Screen : 900mmL x 350mmHT - 18mm Thick Al. Framed Fabric Magnetic Screen with in-built Accessories Rail mounted on table top
with Powder coated Studs
120 Return Screen : 8mm Sandwich Glass Screen of 350mmHt x 525mmL mounted on table top with metal powder coated studs Nos. 10,925.00
Modesty : 12/18mm thick PLT modesty leg to leg for privacy of 450mmHt with 225mm Floor Clearance Gap
Wire Management
250mm Ht Racway with 65mm Dia Wire Manager Grommet
Vertical Raceway with built in separator for power and data of size 250H X 70mm thick with provision to mount swicthes and sockets on
laminate facia with Vertical Wire Entry cover for wire uptake from floor to raceway with 65mm Dia Wire Manager Grommet.
TABLE SIZE Linear shaped :-1200 x 600 & 750mm height
Providing and supply Top 36 mm thick made of PLY with 1 mm thick laminate finish with 2 mm thick PVC edge bidding matching with same
laminate finish. Apron 18mm thick PLY board with 1mm thick laminate finish with 2 mm thick PVC edge matching with laminate bidding,
121 under structure made of 50x50mmx1.6mm thick MS square pipe with powder coated (50-60 micron) finish. WIRE MANAGEMENT MS- Nos. 29,325.00
Powder coated wire tray with pop up box switch plate and vertical cable raisers / PVC wire guard are considered for wire management.
TABLE SIZE Linear shaped :-1350 x 600 & 750mm height
Providing and supply Top 36 mm thick made of PLY with 1 mm thick laminate finish with 2 mm thick PVC edge bidding matching with same
laminate finish. Apron 18mm thick PLY board with 1mm thick laminate finish with 2 mm thick PVC edge matching with laminate bidding,
122 under structure made of 50x50mmx1.6mm thick MS square pipe with powder coated (50-60 micron) finish. WIRE MANAGEMENT MS- Nos. 29,325.00
Powder coated wire tray with pop up box switch plate and vertical cable raisers / PVC wire guard are considered for wire management.
Providing and Fixing coustmised conferece table of 3000x1200x750 STRUCTURE:- Set of table top, modesty and gable end designed in
handshake pattern to build the closed module, open module of Video conferencing pattern V-shaped configuration of the conference table
with infinite seating arrangement depending upon space available to set the conference table. TABLE TOP:- 30mm thick table top made up
of 18mm thick ply wood with 1 mm thick laminate board with 12mm thick thin PVC foil wrapped decorative profile made up of ply fixed along
all the edges from the bottom side which provide decorative waterfall edge profile to top with twin colour look the decorative trim to be
connected at the angle of 45 degrees with each other. Single seater small top of size 675mm width and 600mm depth. Two-seater big top of
size 1350mm width and 600mm depth can shape open type and O shape close type configuration. Two-seater end top of perfect semicircle
shape of the radius of 600mm usable for the close module with the lowest space of 1200mm in front to front seating. LEG:- 25mm thick Leg
123 or Gable End made up of 25mm thick pre-laminated particle board with MS leveller bracket to give floating look. MODESTY:- Modesty Nos.. 92,863.00
Panel made up of 18mm thick ply wood with 1 mm thick laminate providing stability to structure and allow sufficient leg privacy to the user.
"D" headed decorative aluminium profile fixed on it. WIRE MANAGEMENT:- Provision for wire passing throughout the structure without
mixing data and power connections. The wires can be pulled inside the table from floor and placed in the boxes build below openable
shutter. The access point for data and power can be mount on the main top as well as the openable top. Access flap is box structure made
up of aluminium extrusion with necessay switches and sockets and connectivity to different equipments. etc all complete with necessary
hardware and complete as directed by engineer incharge. all visible and non visible surfaces to be claded with 1 mm thick laminate as per
detail design drawings.
WIRE MANAGEMENT:- Provision for wire passing throughout the structure without mixing data and power connections. The wires can be
pulled inside the table from floor and placed in the boxes build below openable shutter. The access point for data and power can be mount
on the main top as well as the openable top. Access flap is box structure made up of aluminium extrusion with necessay switches and
sockets and connectivity to different equipments. etc all complete with necessary hardware and complete as directed by engineer incharge.
all visible and non visible surfaces to be claded with 1 mm thick laminate as per detail design drawings.
Item no. Item Description Unit Rate Total Qty. Amount
CIRCULAR MEETING TABLE - 1500 mm DIA & 750 mm height
Providing fixing and arranging meeting Table Supplying and placing in position table having Top 25 mm thick made of PLY with
124 mm thick laminate finish with 2 mm thick PVC edge bidding matching with same laminate finish End Legs: MS powder coated Nos.. 28,750.00
square perform legs (50X50 mm) as per shape shown in image. Wire Management: 300mm Aluminium Flip Up and provision to
mount switches and sockets on PVC cable dump.Wire Entry: Vertical Wire Entry Cover or Vertebra etc complete
Providing and fixing lockable cupboard of size 1200x450x2100 mm with 4 shelves two parts. Material – 0.7mm thick (+/-0.07mm) CRCA for
shelf; 0.8mm thick (+/-0.08mm) high yield strength CRCA for doors & back; 0.9mm thick (+/-0.08mm) CRCA for all other components. It
should have 2 way locking mechanism with shooting bolt & rase s per req.handle or without handle.. It should have height wise adjustable
125 shelf With uniformly distributed load capacity per each full shelf 40kg maximum. Finish – Epoxy Powder Coated to the thickness of 50 Nos.. 38,123.00
microns (+/-10).etc complete with all necessary hardware. all handles to be consealed. no hinges to be visibal. shade of powercoating will
be as per architect's choice.
Providing and fixing File Storage.1500x450x750mm Top made of 25 mm thick PLY bothside covered 1 mm thick laminate finish ,sides
mm thick PLY bothside covered 1 mm thick laminate finish.9mm thk PLY bothside coberd with laminate finish.Skirting and Front
Shutters/drawer fascia made of 18 mm thick ply bothside covered 1 mm thick laminate finish with necessary hinges and lock. Shutter
126 hanging on Hinges, Lock and handle are consealted or profile or groove handle less etc.All edge 2mm thick Pvc beading matching with Nos.. 46,432.00
laminate will be provided.etc all necessary hardware included and complete as per image and detail design and drawings. all laminate
shaed are to be as per architects's selection.
Supply, fabrication, and installation of modular kitchen cabinets using economical materials, with carcass made of commercial plywood or
pre-laminated particle board finished with 0.8 mm laminate or pre-laminated surfaces on both sides and basic edge banding to exposed
edges, shutters made of commercial plywood or MDF finished with 0.8 mm laminate on the outer face and white or balancing laminate on
the inner face, and provision of drawers using basic telescopic channels (non-soft close) along with stainless steel (SS) wire trolleys in place
127 of tandem systems, including basic cutlery tray and essential storage accessories; all visible surfaces to be finished in matching laminate RMT 24,438.00 387.00
shades selected and approved by the Architect/Engineer-in-Charge, and the work to include complete installation of the kitchen unit with all
necessary basic hardware such as hinges, handles, channels, fittings, and accessories as per drawings and site requirements
Providing and fixing in position PVC Frosting Glass film of approved make (of any pattern, shade and type) on glass partitions and doors for
internal use. Film shall be pasted on glass without any appearing any air bubble. The rates shall be for all shapes and all heights with
128 necessary scaffolding complete as per the Architectural drawings and manufacturer's specification & instructions as directed by the SQM 1,467.00
Architect and Engineer-in-charge. Film shall be with 10 years warranty.
Providing and fixing roller blinds with composition 100% Polyester . Fabric woven and semi opaque / coated translucent fabric & Complete
Blackout. The fabric shall be enclosed in the suitably created pocket along with tube i.e Palmate. Fabric Warranty 3Year. Weight 190 GSM,
Width 280 cm, Thickness 0.48mm, Light fastness is 4 to 5 grade. Mechanism made in UK with ball chain mechanism & with 5 years
mechanism warranty. The Roller tube extruded by non-rusting Aluminium alloy with 1.25 mm thickness. Available in 32, 38, &45 mm
diameters for small and big blinds respectively. Mechanism is designed with support beam to keep it straight and have a pocket for holding
the fabrics in position. The mounting brackets shall be universal and capable of mounting inside/ outside/ ceiling / wall with the clutch on
either the right or left end of the tube. Mechanism to be operated with control unit made of high strength ABS plastic. Mechanism shall be
operating with the use of a ball chain, made up of unbreakable polyethylene plastic, 1.50mm polyester cord with 4.50 mm balls. The blind
shall be able to stop at any desired position with the help of stop lock. The bottom channel of Roller Blind shall be matching shade with
fabric and made of non-rusting aluminium powder coated with 1.50 mm thickness. The fabric shall be enclosed in the suitably created
pocket along with tube.
Item no. Item Description Unit Rate Total Qty. Amount
Parking Suspended Sign : Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-
2-2008 tensile strength 190 MPa made from virgin homogeneous aluminium billet) with Premium grade Anodizing (Thickness 15-20
microns) as per International standards, with 10 years warranty under normal working conditions.Sign is double sided 50 mm depth profile
130 with media accomodation depth of 6 mm media of ACP acrylic upto 5 mm thickness can be pasted directly on frames or attched on frame Nos.. 33,350.00 3.00
with help of dual lock tape.Sign can be edge lite with help of edge lite led modules ,led of LUCOLED make EL31 , fitted and installed at site
in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge. - S1
Door Nameplate Sign - Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-
2008 tensile strength 190 MPa made from virgin homogeneous aluminium billet) with Premium grade Anodizing (Thickness 15-20 microns)
as per International standards, with 10 years warranty under normal working conditions.Sign is single sided with 1 aluminium profile click
131 fitted on 2 plastic moulded endcaps.Sign is including all plastic injection moulded end caps black in shade which are directly press fitted Nos.. 1,988.00 60.00
,media can be flat bed UV printed on panels/ profiles.Cosign make MPI panels fitted and installed at site in plumb and level at specified
location as per drawing to the satisfaction of the engineer-in-charge.
Floor directory sign - Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-
2008 tensile strength 190 MPa made from virgin aluminium homogeneous billet) with Premium grade Anodizing (Thickness 15-20 microns)
as per International standards, with 10 years warranty under normal working conditions.Sign is single sided with aluminium side tracks and
132 common click clips for panel fitting. a.Sign is including all plastic injection moulded clips black in shade which are slided in side tracks SQM 2,070.00 1.00
,media can be flat bed UV printed on panels/ profiles.Cosign make MPI panels fitted and installed at site in plumb and level at specified
location as per drawing to the satisfaction of the engineer-in-charge.
Toilet Door Sign - Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008
tensile strength 190 MPa made from virgin homogeneous aluminium billet) with Premium grade Anodizing (Thickness 15-20 microns) as
per International standards, with 10 years warranty under normal working conditions.Sign is single sided with 1 aluminium profile click fitted
133 on 2 plastic moulded endcaps.Sign is including all plastic injection moulded end caps black in shade which are directly press fitted ,media Nos.. 746.00
can be flat bed UV printed on panels/ profiles.Cosign make MPI panels fitted and installed at site in plumb and level at specified location as
per drawing to the satisfaction of the engineer-in-charge.
Closet Door sign - Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008
tensile strength 190 MPa made from virgin homogeneous aluminium billet) with Premium grade Anodizing (Thickness 15-20 microns) as
per International standards, with 10 years warranty under normal working conditions.Sign is single sided with 1 aluminium profile click fitted
134 on 2 plastic moulded endcaps.Sign is including all plastic injection moulded end caps black in shade which are directly press fitted ,media Nos.. 746.00 5.00
can be flat bed UV printed on panels/ profiles.Cosign make MPI panels fitted and installed at site in plumb and level at specified location as
per drawing to the satisfaction of the engineer-in-charge.
Lift Number sign - Providing sign of Cosign make Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008
tensile strength 190 MPa Made from virgin homogeneous aluminium billet) with premium grade anodizing (Thickness 15-20 microns) as
peinternational standards, with 10 years warranty under normal working conditions. Profile to form frame with overall depth of 10 mm with
135 media of thickness upto 3mm. 2 mm thick acrylic/ACP . I-sign Fix profile of Cosign make with M.S zinc coated corners with grub screws. Nos.. 1,380.00 20.00
Installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge.
Emergency Exit sign - Providing ready sign & fixing at location a Cosign make emergency exit sign- illuminated, surface mount (wall or
ceiling) Dual sided made up of plastic material , battery backup of 3 hours (180 mins) .Battery life of 300 cycles of charge & discharge Li-
ion battery 3.7 Volt, 100 mA, Charge time of 24 hours. Input voltage 220-240 Volt A.C, 50/60 Hz. Viewing distance 30 meter, degree of
protection IP20 (rating for protection against solid object upto 12 mm) white light colour full back (white colour) LED illumination with green
white coloured graphic inserted on both sides on 0.4 mm PC (sizes, texts, symbols or graphics as per standard safety norms & regulations)
graphic options of -left ,right, up staircase down staircase. Test facilty button self test plus auto self test, opreration in maintained and non
maintained mode (power saver mode).Sign with 12 months warranty for electric circuit & 6 months warranty for battery. Sign provided with
dual mounting arrangement of mounting on wall & celing both ( with flat rigid support/base).Sign is including all connection wires (upto
mtr) & high tensile strength zinc coated self tapering screws (4 Nos. with screw wall plastic packing), installed at site in plumb and level at
specified location as per drawing to the satisfaction of the engineer-in-charge.
Item no. Item Description Unit Rate Total Qty. Amount
BUILDING SIGNAGE - Aluminium Channel Letters -
Specifications:
Supply and installation of 1mm thick and 4" depth Aluminium Channel letters with proper backside fabrication with 3mm acp female and
3mm acrylic having led of GOQ 3 Genius 2835 having 5 years warranty and power supply of Union/E-power with 5 years warranty. Wiring
to be done by using 1.5mm wire of Finolex brand.
5 Years warranty Power dissipation ‐
View angle ‐ 175 Luminous flux ‐ 90lm
Colour cct ‐ Pure White, 10000k Cool
white Dimensions (mm) 66*15*10.5._
TOTAL AMOUNT FURNITURE WORK
TOTAL AMOUNT FURNITURE WORK
L MEPF CIVIL WORK
Design, supply, delivery and installation of FRP Surface Heavy Duty Recessed Manhole Cover with Frame (450mm x 450mm clear
138 opening) for sewer manholes and storm water catchpits, including proper seating in RCC top slab, alignment, grouting, finishing and all Nos.. 8,867.00
complete as per drawings and specifications, including all materials, labour, tools, transportation, and fixing at site.
Design, supply, delivery and installation of FRP Surface Heavy Duty Recessed Manhole Cover with Frame (600mm x 600mm clear
139 opening) for sewer manholes and storm water catchpits, including proper seating in RCC top slab, alignment, grouting, finishing and all Nos.. 17,118.00
complete as per drawings and specifications, including all materials, labour, tools, transportation, and fixing at site.
Design, supply, delivery and installation of FRP Water Gully cover with Frame Heavy Duty (600mm x 600mm clear opening) for valve
140 chambers, including proper seating in RCC top slab, alignment, grouting, finishing and all complete as per drawings and specifications, Nos.. 13,082.00
including all materials, labour, tools, transportation, and fixing at site.
Providing, supplying and fixing FRP moulded grating of 38mm thickness, panel size 310mm x 1220mm, including cutting to required sizes,
141 proper placement over supporting frame, fixing with suitable clamps/fasteners, alignment, and all necessary accessories, complete as per Nos.. 1,271.00
drawings and specifications.
TOTAL AMOUNT MEPF CIVIL WORK
TOTAL AMOUNT MEPF CIVIL WORK
AHMEDABAD MUNICIPAL CORPORATION
Construction of Fire Station and Staff Quarters at Kathwada T.P 117 F.P. 364 at Nikol
Ward, East Zone, Ahmedabad city under Building Project Department.
SUBESTIMATE - 03 : HVAC WORK
S. NO. ITEM DESCRIPTION AMOUNT
B AIR DISTRIBUTION NETWORK
D CIVIL STRUCTURE SUPPORT
E VENTILATION FAN
Total of HVAC Works
F Sub Total - Comprehensive Maintenance
TOTAL OF MAINTENANCE & OPERATION FOR HVAC
AHMEDABAD MUNICIPAL CORPORATION
Construction of Fire Station and Staff Quarters at Kathwada T.P 117 F.P. 364 at Nikol Ward, East Zone, Ahmedabad city under Building Project Department.
SUBESTIMATE - 03: HVAC WORK
Item Description Unit Rate Amount
MECHANICAL WORKS
Providing and erecting approved make split air-conditioning unit consisting of copper condensing unit with fan motor, hermetically sealed rotary compressor with accessories
1.0 etc. duly connected separately erected evaporating unit and blower motor with its accessories by means of extra supplied proper insulated copper tubing,drain PVC pipes
suitable for ( cost includes powder coated Stand, Eco Friendly green gas charging, 15A plug top & Remote Control) with necessary core cutting.
(1)For ISEER Range (KWH/KWH)(3.1 to 3.99) Premium Category
1.1 [a] For 0.8 to 1.0 Ton Capacity Nos. 42,885.00 2.00
1.2 (b) for 1.5 ton capacity Nos. 57,116.00 2.00
1.3 (c) for 1.7 to 2.0 ton capacity Nos. 64,577.00 1.00
Providing and erecting Inverter based approved make Cassette type split air-conditioning unit consisting of condensing unit with fan motor, hermetically sealed scroll/rotary
2.0 compressor with accessories etc. duly connected separately erected evaporating unit and blower motor with its accessories by Eco friendly Green gas charging & Internal
copper wiring & Remote control ( 3 star and above of current year) with necessary core cutting.
2.1 (B) for 2 ton capacity Nos. 87,925.00 4.00
2.2 (E) for 4 ton capacity Nos. 1,75,581.00 1.00
3.0 Supplying & installing MS standard type stand mounting for outdoor unit of Split A.C. upto 4 TR capacity erected with necessary hardware materials as directed. Each 739.00 10.00
Supplying and erecting insulated pair of soft copper tubing open or concealed including power and control cable,necessary PVC drain pipes for Split AC machine up to 4 TR
Supplying and installing MS angle , powder coated / Painted standard type of wall/floor stand mount for outdoor unit of split AC of following capacity, erected with necessary
5.0 hardware materials as directed. Each 1,348.00 5.00
(A) 25mm*25mm*3mm thick M.S angle suitable for upto 2 TR. Capacity of ac machine
6.0 DRAIN PIPING :
Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation.
A SUB TOTAL - DX SYSTEM
B AIR DISTRIBUTION NETWORK
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber
7.0 gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness
complete as required.
7.1 Thickness 0.63 mm sheet (22 Gauge) (24 Gauge) SQM 1,296.00 5.00
7.2 Thickness 0.80 mm sheet (20 Gauge) (22 Gauge) SQM 1,504.00 25.00
Item Description Unit Rate Amount
7.3 Thickness 1.00 mm sheet (22 Gauge) (20 Gauge) SQM 1,663.00 10.00
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows,
splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
8.1 Thickness 0.63 mm sheet (22 Gauge) (24 Gauge) SQM 1,245.00 5.00
8.2 Thickness 0.80 mm sheet (20 Gauge) (22 Gauge) SQM 1,453.00 5.00
8.3 Thickness 1.00 mm sheet (22 Gauge) (20 Gauge) SQM 1,867.00 5.00
9.0 SUPPLY, INSTALLATION, TESTING, COMMISSIONING OF DUCT DAMPERS
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc,
as per specifications.
Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control
wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being
9.2 restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete SQM 11,905.00 1.00
as required and as per specifications.
(A) Fire damper
9.3 (B) Actuator Each. 11,153.00 1.00
B SUB TOTAL - AIR DISTRIBUTION NETWORK
10.0 UNDER DECK INSULATION :
10.1 Supply & Fixing Under deck Insulation with 50 mm thick Fire Retardant Extruded Polystyrene having density of 32 Kg / M3 and thermal resistance of 1.78 M2 K / W SQM 850.00 175.00
C SUB TOTAL -DUCT INSULATION
D CIVIL STRUCTURE SUPPORT
11.0 DRAIN PUMP
Supply, Installation, testing & Commissioning of inline pump with appropriate capacity and OEM approved pump for Hi_wall / FCU / Ductable / Any kind of Dx/VFD/AHU unit
with decorative panels, Hanging arrangements, controls & communication cables, 2mtr. Head and necessary fixing arrangements.
D SUB TOTAL -CIVIL STRUCTURE SUPPORT
E VENTILATION FAN
12.0 WALL MOUNTED PROPELLER EXHAUST FAN
12.1 Supplying & erecting approved make low noise decorative exhaust fan having square frame ABS body with inbuilt louvers & square frame.
250 mm with 1350 RPM - Cat. || Nos. 1,687.00 4.00
13.0 Cassette type exhaust fan
Item Description Unit Rate Amount
14.0 Lift pressurization System
Supplying, installation, testing and commissioning of AMCA Certified (For Air and Sound Performance) ceiling hung / floor mounted AXIAL flow fans of following capacity with
GSS casing/ standard M.S. construction and aluminium alloy impellers with high efficiency aero-foil sections, blades. The impeller shall be directly driven by TEFC induction
motor with high efficiency class IE2 . Motors shall be suitable for 3 Phase, 50 Hz, 415V ± 10 %. Motors to be of class 'H' insulation for Supply/Fresh Air Fans and class 'H'
insulation/ 300° C for 2 hrs for smoke or normal Exhaust Fans. The Exhaust air fans-motor assembly should be CE Listed as per EN-12101-3: 2015.. Motor make shall be
same as mentioned on the fire certificate. Fan total efficiency should not be less than 70%. Entire fan model & AMCA Seal shall appear in technical submittal of fan. The
Axial fans shall have sound level not more than 75 dB(A) at three meter distance at both ends when measured in closed room conditions. Static pressure calculation of Fans
shall be checked by Vendor/Contractor prior to supply of Fans as per site condition. If there is any discrepancy against the BOQ, the Vendor/Contractor has to take approval
from Client & Consultant, and nothing extra shall be paid.
Necessary starter shall be in scope of HVAC Contract. Power cable will be available up to starter panel. The starter should be capable to run automatically in case of fire.
14.1 7500 CFM 18 mm WC ESP ( Liftwell Pres. System ) Set 75,000.00 4.00
E SUB TOTAL - VENTILATION FANS
TOTAL HVAC WORKS
AHMEDABAD MUNICIPAL CORPORATION
Construction of Fire Station and Staff Quarters at Kathwada T.P 117 F.P. 364 at Nikol Ward, East Zone, Ahmedabad city under
Building Project Department.
SUBESTIMATE - 03: HVAC WORK
Item no. Item Description Unit Rate Total Qty. Amount
ANNUAL MAINTENANCE CONTRACT
(Note : From Each RA Bill, 5% retaination money to be deduct
during O&M Period)
Comprehensive AMC for SITC of High Side units and
Ventilation System
It includes all preventive maintanance , break down maintanance
1.0 with all spares - repair or replacement of the defactive part or
parts , this includes all cosumable if any applicable.
1.1 1st year ( From the date of Completion of DLP ) Months 3,776.13 12.00
1.2 2nd year ( From the date of Completion of DLP ) Months 3,776.13 12.00
1.3 3rd year ( From the date of Completion of DLP ) Months 3,776.13 12.00
1.4 4th year ( From the date of Completion of DLP ) Months 3,776.13 12.00
Sub Total - Comprehensive Maintenance
AHMEDABAD MUNICIPAL CORPORATION
Construction of Fire Station and Staff Quarters at Kathwada T.P 117 F.P. 364 at Nikol Ward, East Zone, Ahmedabad city under Building Project
SUBESTIMATE - 04 : ELECTRICAL & ELV WORK
S. NO. ITEM DESCRIPTION AMOUNT
A Electrical Works
3 SERVO STABILIZER
4 JUNCTION BOXES
5 DISTRIBUTION BOARD
6 LT CABLES & CABLE TERMINATION
8 INTERNAL WIRING
9 INDOOR LIGHT FIXURE
12 SAFETY ITEMS
13 EXTERNAL LIGHT FIXTURE AND POLE
14 DWC PIPE AND CHAMBER
16 SERVICE WORK
17 RACEWAY/TRUNKING & JUNCTION BOX
Total of Electrical Works
18 FIRE DETECTION & ALARM SYSTEM
19 PUBLIC ADDRESS SYSTEM
20 VOICE COMMUNICATION SYSTEM
Total of ELV Works
AHMEDABAD MUNICIPAL CORPORATION
Construction of Fire Station and Staff Quarters at Kathwada T.P 117 F.P. 364 at Nikol Ward, East Zone, Ahmedabad city under Building Project
SUBESTIMATE - 04 : ELECTRICAL & ELV WORK
S. NO. ITEM DESCRIPTION AMOUNT
C Maintenance & Operation for Electrical & ELV Works
21 MAINTENANCE & OPERATION FOR ELECTRICAL & ELV WORK
E Comprehensive Maintenance for Lift Works
23 COMPREHENSIVE MAINTENANCE FOR LIFT WORK
F CCTV & Networking System Works
25 NETWORKING SYSTEM
Total of CCTV & Networking System Works
G Comprehensive Maintenance for CCTV & Networking System
25 COMPREHENSIVE MAINTENANCE FOR CCTV & NETWORKING SYSTEM
Tender Assumption List.
1 Quntity in this estimate are based on conceptual layouts and information received from various stackholders. It may very as per detial design stage.
AHMEDABAD MUNICIPAL CORPORATION
Construction of Fire Station and Staff Quarters at Kathwada T.P 117 F.P. 364 at Nikol Ward, East Zone, Ahmedabad city under Building Project
SUBESTIMATE - 04 : ELECTRICAL & ELV WORK
S. NO. ITEM DESCRIPTION AMOUNT
For Fire station and residential block LT services considered , Substation , meters space marked on drawing basis of preliminary load. Liason person has
to approve same from supply comapany.
3 All cabling & related assesories upto LT meters are in the scope of supply company, Clients scope start from LT meters onwards.
4 Any specific equipent or requirement for Fire control center excluded from estimate.
AHMEDABAD MUNICIPAL CORPORATION
Construction of Fire Station and Staff Quarters at Kathwada T.P 117 F.P. 364 at Nikol Ward, East Zone, Ahmedabad city under Building Project Department.
SUBESTIMATE - 04 : ELECTRICAL & ELV WORK
Item no. Item Description Unit Rate Total Qty. Amount
Supply, Installation, Testing and Commissioning (SITC) of Silent Type Diesel Generating
(DG) Set(s) of prime power rating (kVA) as specified, complete as a packaged system,
conforming to CPCB IV+ (or better) emission norms, and complying with all applicable
statutory requirements, codes and standards including (but not limited to) IS 4722:1968, IS
13364 (Part 2) and BS 5514 (latest editions/amendments). The DG set shall be suitable for
415 V ±10%, 50 Hz ±5%, 3-phase, 4-wire operation at 0.8 lagging power factor, 1500 RPM,
for tropical conditions, and shall be capable of delivering 10% overload for one (1) hour after
twelve (12) hours of continuous operation (ISO 8528), unless otherwise stated by the OEM.
The scope shall include complete accessories, interconnections, foundations/anti-vibration
arrangements, exhaust system, acoustic enclosure, earthing (as required), consumables for
first commissioning, and all works necessary to render the installation fully functional and
compliant, as directed by the Engineer-in-Charge (EIC). Factory testing shall be carried out
with fuel and load bank at 0.8 power factor and the DG set shall be offered for inspection
prior to dispatch. The DG set shall be provided with a durable QR code/label fixed on the
enclosure/control panel, linking to a document repository containing (as a minimum)
approved GA drawings, wiring diagrams, foundation and installation details, OEM
catalogues, operating & maintenance manuals, factory test reports, type test certificates
(where applicable), warranty certificate, geo-tag of manufacturing location, and rating plate
data as per relevant IS/BS/ISO requirements. The OEM/Contractor shall provide a Remote
Monitoring System (RMS) with minimum one (1) year connectivity (SIM/data plan/server
access as applicable), including dashboard access, user ID/password, and data download
facility. RMS shall, at minimum, capture and report: DG status (Auto/Manual/Off), start/stop
events, kW/kVA/kVAR, V/I/Hz, PF, run hours, fuel level, battery voltage, alarms/trips with
time stamp, and GPS/location (where supported). All licences/subscriptions required for the
stated period shall be included in the quoted price.
Item no. Item Description Unit Rate Total Qty. Amount
(A) Diesel Engine:
Turbocharged, 4-stroke, water-cooled, multi-cylinder diesel engine, suitably rated for the
specified DG set prime rating at site conditions, complete with dynamically balanced
flywheel, heavy-duty engine mounting, and electric starting arrangement. The engine
governing shall be electronic (isochronous/droop as per OEM standard) and shall comply
with ISO 8528/BS 5514 requirements for steady-state speed regulation. Engine shall be
complete with dry type air cleaner with restriction indicator, lube oil cooler (if required),
radiator/cooling package (as applicable), and all sensors/switches required for protections
and annunciation. The engine shall be capable of 10% overload for one (1) hour after twelve
(12) hours continuous operation and shall be suitable for continuous duty under tropical
ambient conditions. The offered engine model shall be CPCB IV+ compliant and shall be
supplied with complete emission control/after-treatment system (including DEF/urea dosing
where applicable) along with all accessories, tanks, pumps, heaters and controls required
for compliant operation. The supply shall include first fill of lubricating oil, coolant and
consumables required for initial commissioning and testing. All fasteners, couplings, guards,
hoses and standard/recommended accessories required for safe and reliable operation
shall be included and shall be subject to inspection/approval by the EIC.
(B) Engine-Mounted Instrumentation/Control Panel:
Engine-mounted instrument/control panel shall be microprocessor based, with LCD/LED
display, event log and alarm/trip annunciation, complete with all wiring, harnesses and
terminations. Indications/protections shall include (minimum) the following and any
additional protections recommended by the OEM: (i) Start/Stop key switch and/or push
buttons with emergency stop; (ii) Output breaker: suitably rated 4-pole ACB/MCCB/MCB as
applicable, with minimum 25 kA rupturing capacity (or as per fault level at site, whichever is
higher), with shunt trip where required; (iii) Jacket water/coolant temperature – indication
and high temperature alarm/trip; (iv) Lube oil pressure – indication and low pressure
alarm/trip; (v) Lube oil temperature (where provided) – indication/alarm; (vi) Battery charging
indication, battery voltage indication and charging failure alarm; (vii) Engine speed (RPM)
indication and overspeed trip; (viii) Engine running hours meter (non-resettable); (ix) Fuel
level indication and low fuel alarm; (x) Fail-to-start / crank fail alarm; (xi) Under/over
frequency and under/over voltage protection (alternator side) as applicable; (xii) Common
alarm and common trip indication with potential-free contacts for BMS/remote annunciation.
All meters/indications shall be of proven industrial quality and the panel shall be wired,
ferruled and labelled. The contractor shall submit wiring diagrams, protection settings and
datasheets for approval prior to dispatch/installation.
Item no. Item Description Unit Rate Total Qty. Amount
(C) Alternator:
Synchronous, brushless alternator of appropriate kVA rating, 415 V, 3-phase, 50 Hz,
RPM, 0.8 lagging PF, continuous duty, dynamically balanced rotor, self-cooled, self-excited
and AVR regulated. Enclosure shall be SPDP, minimum IP23. Insulation shall be Class H
with suitable tropicalization; temperature rise shall be within limits of the applicable standard.
The alternator shall comply with IS 13364 (Part 2), IS 4722 and/or BS 2613 (latest), as
applicable. Voltage regulation with AVR shall be within ±1.0% (steady state) or OEM
standard whichever is better. The alternator shall be capable of 10% overload for one (1)
hour after twelve (12) hours of continuous operation. Harmonic distortion shall be suitable
for non-linear loads; alternator shall be equipped with appropriate AVR features (e.g., soft
1.1 start, UFRO) and shall be suitable for motor starting duties typical to the installation. Each 32,68,331.00 1.00
Terminals shall be brought out to a terminal box with adequate space for termination and
shall include earthing terminals. All routine/type test certificates (as applicable) shall be
submitted for acceptance.
(D) Base Frame & Foundation: Engine and alternator shall be mounted on a suitably
designed, fabricated MS channel base frame with stiffeners, lifting arrangement and
coupling guard, duly painted/treated for corrosion protection. The set shall be installed on an
adequately designed cement concrete foundation/pedestal with anchor bolts, pockets,
grouting and anti-vibration mounts (AVMs) / spring isolators as per OEM recommendations
and site conditions. Vibration levels shall be within OEM permissible limits. The contractor
shall be responsible for alignment, levelling, tightening torque and re-check after load trial,
complete in all respects.
(E) Fuel Tank: In-built/base fuel tank fabricated from minimum 3 mm thick MS sheet, duly
leak-tested, complete with filling arrangement, vent, drain, cleaning opening, level indication
and isolation valve(s). The capacity shall be adequate for minimum eight (8) hours
continuous operation at full load. Fuel piping between tank and engine shall be MS ‘C’ class
pipes of suitable diameter with compatible flexible connections (where required), complete
with all valves, clamps, supports, unions and fittings. Any additional safety provisions
required by local fire authority/UGVCL/competent authority (such as double wall/bunding,
flame arrestor, etc.) shall be provided within the quoted scope.
(F) Exhaust System: Heavy-duty residential type exhaust silencer suitable for CPCB IV+
installation (with DEF/after-treatment system wherever applicable) along with exhaust piping
of required length, bends, supports and flexible bellow, complete with rain cap, drain
arrangement and all accessories. Exhaust piping shall be thermally insulated/lagged and
cladded where required to ensure personnel safety and to limit heat radiation inside the DG
room/enclosure. The complete exhaust arrangement shall be designed such that engine
exhaust back pressure remains within OEM permissible limits and shall comply with
applicable statutory and safety requirements.
Item no. Item Description Unit Rate Total Qty. Amount
(G) Starting System:
12 V / 24 V DC electric starting system (as per OEM design) comprising starter motor(s),
battery charger/alternator charging arrangement, relays, cabling and terminals, complete
with maintenance-free batteries of suitable Ah capacity to ensure minimum three (3)
consecutive cranking attempts. System shall include battery isolator and indication of
charging healthy/failure. All battery interconnections shall be with crimped lugs, insulated
sleeves and proper supports, complete in all respects.
(H) Acoustic and Weatherproof Enclosure: Acoustic enclosure shall be factory-fabricated,
weatherproof and corrosion protected, suitable for outdoor installation, with minimum IP65
protection (or better) for the enclosure body. Enclosure design shall provide adequate fresh
air intake and hot air discharge for engine radiator and alternator cooling such that the
internal temperature rise remains within OEM limits at full load. Provision shall be made for
safe access/maintenance including lockable doors, viewing window (where provided),
emergency stop access, and cable entry glands. Noise level of the complete DG set with
enclosure shall not exceed 75 dB(A) measured at 1.0 m distance in free field conditions, in
accordance with applicable CPCB requirements. The enclosure shall comply with CPCB IV+
(or better) requirements and other applicable local rules/regulations. All louvers, acoustic
infill/insulation, fasteners and sealing arrangements shall be of fire-retardant/industrial grade
as per OEM standard. Any deviation from the specified noise/IP requirements shall be
treated as non-compliance unless explicitly approved by the EIC in writing.
Erection, testing, commissioning and satisfactory performance demonstration shall be
carried out as per site requirements and as directed by the Engineer-in-Charge. The scope
shall include pre-commissioning checks, insulation resistance tests, no-load and load trials,
safety/protection checks, and performance test on load bank (where directed) with
submission of test records. The contractor shall provide initial consumables including first fill
of diesel fuel (minimum up to 80% of fuel tank capacity), lubricating oil, coolant, etc. required
for commissioning and the specified tests. The bidder/OEM shall provide comprehensive
warranty/guarantee for the complete DG system (engine, alternator, control panels, RMS,
enclosure and all accessories) for a minimum period of two (2) years from the date of
commissioning/handing over, whichever is later, covering defects in materials and
workmanship. During warranty, all spares/repairs/replacements and visits required to
maintain the DG set in serviceable condition shall be carried out at no additional cost. All
necessary statutory approvals, inspections, testing and certification from the Electrical
Inspector/competent authority (including provision, testing and sealing of energy meter(s)
wherever applicable) shall be arranged and obtained by the contractor within the quoted
scope and time, at no extra cost. Required O&M manuals, as-built drawings, warranty
certificates and training to operating staff shall be provided prior to handing over.
Note: The DG set specifications shall comply with the latest CPCB guidelines/notifications
and all applicable local rules/regulations prevailing as on the last date of tender submission
applicable local rules/regulations prevailing as on the last date of tender submission
(S) Continuous rating of 320 KVA ,BHP not less than 375 BHP
Item no. Item Description Unit Rate Total Qty. Amount
Free standing floor mounted IP 42 automatic mains failure control panel including
auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers,
set of CTs for metering & protection and energy analyser to indicate currents, phase and
line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour
(KVARH), KVA (Phase & Total), KW (MFM) & provision for overload, short circuit,
restricted earth fault, under frequency, all complete and inter locking and
communication/ Ethernet /RS485/SNMP port open protocol for BMS integration
including suitable software, the panel shall be of DG Set. as per approved by
Engineering in charge and including the following:
1. Suitable numbers and appropriate capacity 4 ACB/ MCCB with electronic release for
O/C & E/F and shunt trip. (Icu=100%Ics) (Not below 25KA Breaking Capacity at 415Volts),
(Total Three Breakers)
2. Auto/Manual/Test/Off selector switch
3. Protection for under and over voltage phase reversal (2 nos Over voltage
relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay).
4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for
5. Energy analyser unit to indicate current, Voltage( L- N & L_L), kW, kVA (Phase & Total),
Frequency, KWH, PF.
6. LED Indicating lamps for load on mains and load on set
7. Fuse/ MCB for instruments
8. Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter,
selector switch for trickle, off and boost and current adjustment.
9. Control/Signal/Multi core/Communication Cables between DG Set and AMF Panel upto
1.2 10. Main supply failure monitor Each 2,81,832.00 1.00
11. Supply failure timer
12. Restoration timer
13. Control unit with three impulse automatic engine start/stop and failure to start
14. Impulse counter with locking and reset facility.
15. ON/OFF/Control circuit switch with indicator
Item no. Item Description Unit Rate Total Qty. Amount
16. Audio/Video annunciation for
(i) High water temperature
(ii) Low lubricating oil pressure
(iii) Engine over speed
(iv) Engine fails to start
(v) Full load/maximum load warning
16. Protection for over/under Frequency, Loss of AC sensing, Over Current,
Unbalancing load with suitable number of relays and accessories
17. Maintenance notification based on Engine Run Hour & due date.
18. Load Management through PLC to achieve auto opening and closing of incomer
breakers, bus coupler switching of essential panel , interlocking providing signal to
AMF Panel for load status and AMF shall give command to DG Set to auto start /
auto stop depending upon load status and requirement etc. and necessary hardware and
software required to perform the operation shall be provided by the contractor
including all control wiring.
(E) AMF Control Panel for 300 kVA/320 KVA3 phase DG Set
Sub Total 1.....
Item no. Item Description Unit Rate Total Qty. Amount
Supply, installation, testing and commissioning of 3 phase 415V 4 wire Free Standing Floor
mounted MV panel made out of minimum 14 SWG CRCA sheet after seventank process
and painting with Epoxy powder coating including all switchgear as detailed below. The
panel having PU/Neoprene rubber gasket of not less than 3mm thickness,separate
detachable, gland plate M.S. base channel, hinged door with locking arrangement for
equipment/switchgear. The panel shall consist of suitable rating FP/TPN Aluminium- busbar-
as per SLD (at the rating of 0.8ASq.mm) supported with DMC/ SMC barriers and colour
coded with Heat shrinkable sleeves. The Metering shall be provided as specified.
The panel shall have Short circuit with standing capacity as given in SLD and consist of the
switchgear as mentioned below. The panel shall be mounted on plinth, stand, etc. including
all materials. The panel shall be got fabricated from manufacturers with CPRI Test certificate
only. All the Panels shall have minimum 25% outgoing as per SLD. The earth bus shall be
continuoulsy run without any jointing/welding and its Size should be per SLD. The size of all
Panel Mounting Meters shall be 96X96mm.The Panels shall be mounted on U channels
including supply and fixing of the same. MCBs shall be provided for Control purposes. (All
Panels shall be extendable type only). Price shall be inclusive following:
Shifting of panels from site store to the suitable location. Installation of panel as located in
electrical drawings or as per site conditions, including removing packing etc. Earthing all
components, frame etc. to a common internal earth bar. Connection, testing &
commissioning. Electrical contractor shall carry out the insulation test at site & all the
readings shall be submitted in copy to the consultant or engineer-in-charge. Supply,
installation, testing and commissioning all accessories, supporting structure, hard ware etc
to complete the job. Supply, installation, testing and commissioning of necessary tools, hard
ware, testing hard ware, testing equipment etc. The rates for the distribution boards apart
from the Breakers and instruments shall also include the following :
This schedule of Quantities shall be read in conjuction with the technical specification,
General & Special conditions as well as all tender drawings. Supporting rigid steel
framework. Cubicle type, 14 gauge CRCA sheet steel enclosed.
Proper bonding to earth. Painting/lettering on Breakers and distribution boards, the location
they serve, providing on each panel its circuit diagram.
Providing cable clamps / supports within distribution boards cable alley.
All MCB’s shall be of minimum 10 KA breaking capacity.
The breaking capacity of MCCB’s are mentioned panel wise. All MCCB’s shall be with
thermal magnetic releases upto 250 amps and miroprocesR&B R&B SOR based for
amps and above capacity, unless specified otherwise.
All motor feeders MCCBs shall be of motor duty.
Item no. Item Description Unit Rate Total Qty. Amount
Distribution panels shall be Powder Coated with Siemens gray paint shade no. RAL-7032 of
Degree of protection for following type of distribution panel enclosure shall be as per
IP 4x for all Indoor panel.
IP 65 and double door for all outdoor panel.
All MCCB’s shall be provided with operating mechanism for door interlock.
All measuring instruments (Meters) shall be of digital electronic with LED of approved make.
All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire.
All panels shall have provision of the following:
Pad locking of Switch board doors.All MCB’s used for protection of resistive and lightly
inductive load shall be type “B” characteristic and inductive (motor) load shall be of type “C”
characteristic and discharge lamps and UPS etc. shall be of type D characteristic. All
incoming and outgoing air circuit breakers shall be placed on middle portion of the vertical in
single tier formation. SPD as shown in SLD
SITC OF MAIN PANEL FOR FIRE STATION_KATHWADA
2.1 ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & Each 3,52,575.71 1.00
SITC OF COMMON AREA FOR SITE_KATHWADA
2.2 ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & Each 2,94,063.78 1.00
SITC OF PHE PANEL_KATHWADA
2.3 ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & Each 88,318.89 1.00
SITC OF 1BHK COMMON AREA_KATHWADA
2.4 ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & Each 99,577.72 1.00
SITC OF DG PANEL_KATHWADA
2.5 ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & Each 3,23,986.03 1.00
SITC OF EXTERNAL LIGHTING PANEL_KATHWADA
2.6 ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & Each 93,111.95 1.00
Providing & erecting capacitor duty contactor 3 phase, 415 V with proper connection for
2.7 following rating: Each 3,217.00 RO
Item no. Item Description Unit Rate Total Qty. Amount
SITC OF APFC PANEL - 75 KVAR
Design, Supplying, installing, testing of factory fabricated ready made Three phase APFC
Panel Cubical Panel fabrication should be type tested as per IEC 61921, 61439:1&2
Capacitor Duty Contactor for switching as per following Steps Incomer Switch of MCCB type
Icu=Ics=50KA at 400/440 Volts, with OC, SC, internal earth fault protection Incomer Switch
of MCCB type Icu=Ics=50KA at 400/440 Volts, with OC, SC, internal earth fault
protection,Copper tinned insulated Busbar,Cubical panel should be indoor type with IP
and IK 10,Metalized polypropylene film tye3-phase 550Volt Capacitor,De tuning Reactor for
2.8 each capacitor,Panel having Short Circuit and Overload protection,Each step Capacitor Each 2,16,103.00 1.00
having suitable MCB with Sc, OL, internal earth fault relay,Each stage having Stage
Contactor (Capacitor load rating),PF regulator master controller having suitable steps with
LCD display, Rs 485 Communication port, Indication LED Lamps for main incomer and ON-
OFF for each capacitor bank,MS Chanel for Floor mounting, Cable entry as per site
situation,Cooling fans for panel
ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD &
SITC OF APFC PANEL - 125KVAR
Design, Supplying, installing, testing of factory fabricated ready made Three phase APFC
Panel Cubical Panel fabrication should be type tested as per IEC 61921, 61439:1&2
Capacitor Duty Contactor for switching as per following Steps Incomer Switch of MCCB type
Icu=Ics=50KA at 400/440 Volts, with OC, SC, internal earth fault protection Incomer Switch
of MCCB type Icu=Ics=50KA at 400/440 Volts, with OC, SC, internal earth fault
protection,Copper tinned insulated Busbar,Cubical panel should be indoor type with IP
and IK 10,Metalized polypropylene film tye3-phase 550Volt Capacitor,De tuning Reactor for
2.9 each capacitor,Panel having Short Circuit and Overload protection,Each step Capacitor Each 3,54,239.00 1.00
having suitable MCB with Sc, OL, internal earth fault relay,Each stage having Stage
Contactor (Capacitor load rating),PF regulator master controller having suitable steps with
LCD display, Rs 485 Communication port, Indication LED Lamps for main incomer and ON-
OFF for each capacitor bank,MS Chanel for Floor mounting, Cable entry as per site
situation,Cooling fans for panel.
ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD &
Sub Total 2.....
Item no. Item Description Unit Rate Total Qty. Amount
2a SERVO STABILIZER
Supply, Installation, testing and commissioning of Indoor Type Three phase servo-controlled
voltage stabilizer suitable for input voltage range 300 to 480VAC And output voltage range
415V + 1%. A.C Three Phase.Three Phase with Input MCCB & Bypass switch etc., and all
other require components and accessories to finish the job. All required statutory Approval
from respective authority shall be part of Scope. Natural Air Cooled / Oil Cooled with Input
MCB / MCCB & Bypass switch (L&T, ABB, schneider) , Air cooled up to 60 KVA & above oil
2a.1 Rating : 40 KVA (Air cooled) Each 91,057.00 1.00
2a.2 Rating : 200 KVA (Oil cooled) Each 5,10,657.50 1.00
Sub Total 2a.....
3 JUNCTION BOXES
Supply, Transportation, Installation, testing and commissioning of IP-67 Rated weather proof
Outdoor type junction boxes having dimensdios Height x Width x Depth:- 104 x 104 x 70 mm
3.1 with terminal having black colour RAL 7035. with 5 pole terminal set upto 4 sqmm cables Each 904.42 5.00
Supply, Transportation, Installation, testing and commissioning of IP 66/69 weather proof
Outdoor type junction boxeshaving dimensdios Height x Width x Depth:- 155 x 210 x 92 mm
3.2 with terminal having black colour RAL 9011. with 5 pole terminal set upto 16 sqmm cables Each 4,072.96 5.00
Sub Total 3.....
4 DISTRIBUTION BOARD
SPN Distribution Board :
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface
mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 &
IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used
of same company of MCB to be used) suitable for
(A) Single phase incoming and horizontal single phase outgoing
(b) Sheet Steel double door (IP-43)
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface
mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 &
IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used
of same company of MCB to be used) suitable for
(A) Single phase incoming and horizontal single phase outgoing
(b) Sheet Steel double door (IP-43)
Item no. Item Description Unit Rate Total Qty. Amount
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface
mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 &
IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used
of same company of MCB to be used) suitable for
4.3 Each 1,664.00 RO
(A) Single phase incoming and horizontal single phase outgoing
(b) Sheet Steel double door (IP-43)
TPN Distribution Board :
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface
mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 &
IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used
of same company of MCB to be used) suitable for suitable for (PPI DB)
(B) three phase incoming and single phase horizontal type outgoing Per phase
isolation type (PPI)
(b) Sheet Steel double door
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface
mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 &
IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used
of same company of MCB to be used) suitable for suitable for (PPI DB)
(B) three phase incoming and single phase horizontal type outgoing Per phase
isolation type (PPI)
(b) Sheet Steel double door
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface
mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 &
IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used
of same company of MCB to be used) suitable for suitable for (PPI DB)
4.6 Each 3,836.00 RO
(B) three phase incoming and single phase horizontal type outgoing Per phase
isolation type (PPI)
(b) Sheet Steel double door
Item no. Item Description Unit Rate Total Qty. Amount
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface
mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 &
IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used
of same company of MCB to be used) suitable for suitable for (PPI DB)
4.7 Each 4,620.00 RO
(B) three phase incoming and single phase horizontal type outgoing Per phase
isolation type (PPI)
(b) Sheet Steel double door
VTPN Distribution Board :
Providing and erecting Sheet Steel powder coated Vertical MCB distribution board (VTPN) -
flush / surface mounted double door (IP54) fitted with copper insulated busbar, isolated
neutral bar, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3, suitable for
4.8 63/100 AMP TPN MCCB + RCCB as incomer and three phase outgoing as per following Each 5,760.00 RO
.(The DBs should be used of same company of MCB to be used)
(A)4 way outgoing
Providing and erecting Sheet Steel powder coated Vertical MCB distribution board (VTPN) -
flush / surface mounted double door (IP54) fitted with copper insulated busbar, isolated
neutral bar, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3, suitable for
4.9 63/100 AMP TPN MCCB + RCCB as incomer and three phase outgoing as per following Each 6,433.00 2.00
.(The DBs should be used of same company of MCB to be used)
(B)6 way outgoing
Providing and erecting Sheet Steel powder coated Vertical MCB distribution board (VTPN) -
flush / surface mounted double door (IP54) fitted with copper insulated busbar, isolated
neutral bar, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3, suitable for
4.10 63/100 AMP TPN MCCB + RCCB as incomer and three phase outgoing as per following Each 8,319.00 RO
.(The DBs should be used of same company of MCB to be used)
(C)8 way outgoing
Providing and erecting Sheet Steel powder coated Vertical MCB distribution board (VTPN) -
flush / surface mounted double door (IP54) fitted with copper insulated busbar, isolated
neutral bar, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3, suitable for
4.11 63/100 AMP TPN MCCB + RCCB as incomer and three phase outgoing as per following Each 10,857.00
.(The DBs should be used of same company of MCB to be used)
(D)12 way outgoing
MCB 's and its Accessories
Providing & erecting insulated socket 3P+N+E with Plug16A rating which is comprised of
Four pole MCB slot and insulated socket IP40 Cat-III.
Item no. Item Description Unit Rate Total Qty. Amount
providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to operate
4.13 on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box. Each 122.00 1212.00
confirming to IS 8828/1996 with ISI Mark Cat.III.
Providing & erecting 240 V MCB double pole switch for motor & inductive load having
4.14 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity Each 326.00 1.00
(A) 6 to 32 Amp.
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load having 10KA
4.15 breaking capacity & confirms to IS :8828 in existing box having following capacity Each 649.00 18.00
(a) 6 to 32 Amp. ( Cat.III)
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load having 10KA
4.16 breaking capacity & confirms to IS :8828 in existing box having following capacity Each 729.00 RO
(b) 40 Amp. ( Cat.III)
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load having 10KA
4.17 breaking capacity & confirms to IS :8828 in existing box having following capacity Each 803.00 2.00
(c) 63 Amp. (cat III)
Providing & erecting 415 V MCB three Pole for Motor & Inductive Load having 10KA
4.18 breaking capacity & confirms to IS :8828 in existing box having following capacity Each 641.00 10.00
(a) 6 to 32 Amp. (Cat.III)
Providing & erecting 415 V MCB three Pole for Motor & Inductive Load having 10KA
4.19 breaking capacity & confirms to IS :8828 in existing box having following capacity Each 706.00 6.00
(b)40 Amp.(Cat.III)
Providing & erecting 415 V MCB three Pole for Motor & Inductive Load having 10KA
4.20 breaking capacity & confirms to IS :8828 in existing box having following capacity Each 780.00 4.00
(C)63 Amp. (Cat.III)
Providing and erecting Approved make RCCBs conforming to IS: 12640 and having
sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation
on single phase 240 V,50Hz. having characteristic of quick action & tripping with all advance
4.21 feature & do not incorporate any electronic component. for following Max. rating erected as Each 2,145.00 58.00
(i) 25 Amps.DP ( Cat. III)
Providing and erecting Approved make RCCBs conforming to IS: 12640 and having
sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation
on single phase 240 V,50Hz. having characteristic of quick action & tripping with all advance
4.22 feature & do not incorporate any electronic component. for following Max. rating erected as Each 2,434.00 4.00
(ii) 40Amps. DP ( Cat. III)
Item no. Item Description Unit Rate Total Qty. Amount
Providing and erecting Approved make RCCBs conforming to IS: 12640 and having
sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation
on single phase 240 V,50Hz. having characteristic of quick action & tripping with all advance
4.23 feature & do not incorporate any electronic component. for following Max. rating erected as Each 2,891.00 RO
(iii) 63Amps. DP ( Cat. III)
Supplying & erecting approved make RCCB + MCB (Electro magnetic type only) working
on residual current device having 10 KA short circuit breaking capacity and 30 mAmp.
Sensitivity & 30 mili sec. tripping time conforming to IS 12640 test knob facility trip free
mechanism operating for rated leakage at nominal ten volt, complete erected including all
4.24 materials lugs screws etc. completed. Each 1,978.00 78.00
[a] 6A / 10A / 16A / 20A / 25A 2 pole single phase
Supplying & erecting approved make RCCB + MCB (Electro magnetic type only) working
on residual current device having 10 KA short circuit breaking capacity and 30 mAmp.
Sensitivity & 30 mili sec. tripping time conforming to IS 12640 test knob facility trip free
mechanism operating for rated leakage at nominal ten volt, complete erected including all
4.25 materials lugs screws etc. completed. Each 2,118.00 4.00
[b] 32A / 40A, 2 pole Single Phase
Supplying & erecting approved make RCCB + MCB (Electro magnetic type only) working
on residual current device having 10 KA short circuit breaking capacity and 30 mAmp.
Sensitivity & 30 mili sec. tripping time conforming to IS 12640 test knob facility trip free
mechanism operating for rated leakage at nominal ten volt, complete erected including all
4.26 materials lugs screws etc. completed. Each 2,360.00 5.00
[e] 32A to 40 A, 4 Pole Three Phase
Supplying & erecting approved make RCCB + MCB (Electro magnetic type only) working
on residual current device having 10 KA short circuit breaking capacity and 30 mAmp.
Sensitivity & 30 mili sec. tripping time conforming to IS 12640 test knob facility trip free
mechanism operating for rated leakage at nominal ten volt, complete erected including all
4.27 materials lugs screws etc. completed. Each 3,087.00 RO
[f] 63A, 4 pole Three Phase
4.28 Sheets steel powder coated enclosure suitable for incorporating One/Two nos. MCB. Each 175.00 1.00
4.29 SITC of Sheet steel metal enclouser for FP MCB Each 623.00 1.00
Item no. Item Description Unit Rate Total Qty. Amount
SITC of 80-100 A FP MCCB with thermal magnetic release.
Note:-1 Add Rs. 10% extra for housing/Encloser of MCCB for Item No 3-4-1 to 3-4-12
4.30 (The Enclosures should be used of same company of MCCBs to be used) *Add 35% Each 7,395.30 3.00
additional for microprocessor type of mccb in place of conventional for item no.3-4-1
SITC of 125A FP MCCB with thermal magnetic release with sheet steel metal enclosure.
Note:-1 Add Rs. 10% extra for housing/Encloser of MCCB for Item No 3-4-1 to 3-4-12
(The Enclosures should be used of same company of MCCBs to be used) *Add 35%
4.31 additional for microprocessor type of mccb in place of conventional for item no.3-4-1 Each 9,651.40 RO
SITC of 200A FP MCCB with thermal magnetic release with sheet steel metal enclosure.
Note:-1 Add Rs. 10% extra for housing/Encloser of MCCB for Item No 3-4-1 to 3-4-12
(The Enclosures should be used of same company of MCCBs to be used) *Add 35%
4.32 additional for microprocessor type of mccb in place of conventional for item no.3-4-1 Each 26,235.50 2.00
SITC of 250A FP MCCB with thermal magnetic release with sheet steel metal enclosure.
Note:-1 Add Rs. 10% extra for housing/Encloser of MCCB for Item No 3-4-1 to 3-4-12
(The Enclosures should be used of same company of MCCBs to be used) *Add 35%
4.33 additional for microprocessor type of mccb in place of conventional for item no.3-4-1 Each 33,877.31 RO
SITC of 315-400A FP MCCB with thermal magnetic release with sheet steel metal
Note:-1 Add Rs. 10% extra for housing/Encloser of MCCB for Item No 3-4-1 to 3-4-12
4.34 (The Enclosures should be used of same company of MCCBs to be used) *Add 35% Each 40,803.35 1.00
additional for microprocessor type of mccb in place of conventional for item no.3-4-1
4.35 SITC of IP 65 - outdoor type - 4Way SPN DB Each 1,833.45 1.00
4.36 SITC of IP 65 - outdoor type - 8Way SPN DB Each 2,891.68 1.00
4.37 SITC of Blank Plates Each 9.00 95.00
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth,
metal encloused plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on
4.38 surface or in recess, with chained metal cover for the socket out let and complete with Each 2,024.17 10.00
connections, testing and commissioning etc. as required.
Sub Total 4.....
5 LT CABLES & CABLE TERMINATION
5.1 UNARMOURED COPPER CABLES.
Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 1.1 KV grade to
5.1.1 be erected as directed of following size. Mtr. 170.00 100.00
(E) 3 core 2.5 Sq. mm
Item no. Item Description Unit Rate Total Qty. Amount
Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 1.1 KV grade to
5.1.2 be erected as directed of following size. Mtr. 234.00 10.00
(F) 3 core 4 Sq. mm
Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 1.1 KV grade to
5.1.3 be erected as directed of following size. Mtr. 363.00 10.00
(G) 3 core 6 Sq. mm
Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 1.1 KV grade to
5.1.4 be erected as directed of following size. Mtr. 209.00 100.00
(J) 4 core 2.5 Sq. mm
Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 1.1 KV grade to
5.1.5 be erected as directed of following size. Mtr. 298.00 10.00
(K) 4 core 4 Sq. mm
Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 1.1 KV grade to
5.1.6 be erected as directed of following size. Mtr. 451.00 10.00
(L) 4 core 6 Sq. mm
Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 1.1 KV grade to
5.1.7 be erected as directed of following size. Mtr. 711.00 10.00
(M) 4 core 10 Sq. mm
5.2 ARMOURED ALUMINIUM CABLES
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium
conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe
5.2.1 of following size of cables Mtr. 183.00 10.00
(A) 4 core 16 Sq. mm
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand / Solid
Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing
5.2.2 trench / pipe of following size of cables Mtr. 167.00 10.00
(C) 4 core 10 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium
conductor with water swellable coating which should protect against saline water & for
5.2.3 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of Mtr. 218.00 10.00
(I) 3 1/2 core 25 Sq. mm( 16 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium
conductor with water swellable coating which should protect against saline water & for
5.2.4 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of Mtr. 262.00 50.00
(I) 3 1/2 core 35 Sq. mm( 25 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium
conductor with water swellable coating which should protect against saline water & for
5.2.5 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of Mtr. 339.00 115.00
(C) 3 1/2 core 50 Sq. mm ( 25 Sq.1/2 mm core)
Item no. Item Description Unit Rate Total Qty. Amount
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium
conductor with water swellable coating which should protect against saline water & for
5.2.6 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of Mtr. 450.00 235.00
(D) 3 1/2 core 70 Sq. mm ( 35 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium
conductor with water swellable coating which should protect against saline water & for
5.2.7 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of Mtr. 584.00 240.00
(E) 3 1/2 core 95 Sq. mm ( 50 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium
conductor with water swellable coating which should protect against saline water & for
5.2.8 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of Mtr. 642.00 25.00
(F) 3 1/2 core 120 Sq. mm ( 70 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium
conductor with water swellable coating which should protect against saline water & for
5.2.9 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of Mtr. 868.00 25.00
(G) 3 1/2 core 150 Sq. mm ( 70 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium
conductor with water swellable coating which should protect against saline water & for
5.2.10 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of Mtr. 1,075.00 10.00
(H) 3 1/2 core 185 Sq. mm ( 95 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium
conductor with water swellable coating which should protect against saline water & for
5.2.11 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of Mtr. 1,388.00 505.00
(I) 3 1/2 core 240 Sq. mm( 120 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium
conductor with water swellable coating which should protect against saline water & for
5.2.12 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of Mtr. 1,673.00 75.00
(I) 3 1/2 core 300 Sq. mm( 150 Sq. mm 1/2 core)
5.3 ARMOURED COPPER CABLES
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper
conductor with water swellable coating which should protect against saline water & 1.1 KV.
5.3.1 to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or Mtr. 266.00 10.00
floor of following size of cable.
(A) 3 core 2.5Sq. Mm
Item no. Item Description Unit Rate Total Qty. Amount
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper
conductor with water swellable coating which should protect against saline water & 1.1 KV.
5.3.2 to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or Mtr. 356.00 350.00
floor of following size of cable.
(B) 3 core 4 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper
conductor with water swellable coating which should protect against saline water & 1.1 KV.
5.3.3 to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or Mtr. 490.00 725.00
floor of following size of cable.
(C) 3 core 6 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper
conductor with water swellable coating which should protect against saline water & 1.1 KV.
5.3.4 to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or Mtr. 619.00 10.00
floor of following size of cable.
(D) 3 core 10 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper
conductor with water swellable coating which should protect against saline water & 1.1 KV.
5.3.5 to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or Mtr. 336.00 10.00
floor of following size of cable..
(A) 4 core 2.5 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper
conductor with water swellable coating which should protect against saline water & 1.1 KV.
5.3.6 to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or Mtr. 451.00 360.00
floor of following size of cable.
(B) 4 core 4 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper
conductor with water swellable coating which should protect against saline water & 1.1 KV.
5.3.7 to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or Mtr. 631.00 1000.00
floor of following size of cable.
(C) 4 core 6 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper
conductor with water swellable coating which should protect against saline water & 1.1 KV.
5.3.8 to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or Mtr. 838.00 1080.00
floor of following size of cable.
(A) 4 core 10 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper
conductor with water swellable coating which should protect against saline water & 1.1 KV.
5.3.9 to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or Mtr. 1,223.00 140.00
floor of following size of cable.
(B) 4 core 16 Sq. mm
5.4 CABLE GLANDS.
Item no. Item Description Unit Rate Total Qty. Amount
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC
insulated armoured cable complete with out going tails, insulating tape etc for following size
5.4.1 of cables. Each 33.00 16.00
(A) 2 to 4 core 2.5/4 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC
insulated armoured cable complete with out going tails, insulating tape etc for following size
5.4.2 of cables. Each 38.00 64.00
(B) 2 to 4 core 6 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC
insulated armoured cable complete with out going tails, insulating tape etc for following size
5.4.3 of cables. Each 38.00 34.00
(C) 2 to 4 core 10 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC
insulated armoured cable complete with out going tails, insulating tape etc for following size
5.4.4 of cables. Each 47.00 6.00
(D) 2 to 4 core 16 Sq. mm
Providing and, fixing heavy duty flange type brass double compression type cable gland
with rubber ring for PVC insulated armoured cable complete with out going tails, insulating
5.4.5 tape etc for following size of cables. Each 66.00 2.00
(B) 3 & 1/2 core 25Sq. mm
Providing and, fixing heavy duty flange type brass double compression type cable gland
with rubber ring for PVC insulated armoured cable complete with out going tails, insulating
5.4.6 tape etc for following size of cables. Each 75.00 12.00
(B) 3 & 1/2 core 35/50 Sq. mm
Providing and, fixing heavy duty flange type brass double compression type cable gland
with rubber ring for PVC insulated armoured cable complete with out going tails, insulating
5.4.7 tape etc for following size of cables. Each 102.00 6.00
(C) 3 & 1/2 core 70 Sq. mm
Providing and, fixing heavy duty flange type brass double compression type cable gland
with rubber ring for PVC insulated armoured cable complete with out going tails, insulating
5.4.8 tape etc for following size of cables. Each 130.00 6.00
(D) 3 & 1/2 core 95 Sq. mm
Providing and, fixing heavy duty flange type brass double compression type cable gland
with rubber ring for PVC insulated armoured cable complete with out going tails, insulating
5.4.9 tape etc for following size of cables. Each 139.00 4.00
(E) 3 & 1/2 core 120 Sq. mm
Providing and, fixing heavy duty flange type brass double compression type cable gland
with rubber ring for PVC insulated armoured cable complete with out going tails, insulating
5.4.10 tape etc for following size of cables. Each 189.00 4.00
(F) 3 & 1/2 core 150 Sq. mm
Providing and, fixing heavy duty flange type brass double compression type cable gland
with rubber ring for PVC insulated armoured cable complete with out going tails, insulating
5.4.11 tape etc for following size of cables. Each 236.00 2.00
(G) 3 & 1/2 core 185 Sq. mm
Item no. Item Description Unit Rate Total Qty. Amount
Providing and, fixing heavy duty flange type brass double compression type cable gland
with rubber ring for PVC insulated armoured cable complete with out going tails, insulating
5.4.12 tape etc for following size of cables. Each 245.00 20.00
(H) 3 & 1/2 core 240 Sq. mm
Providing and, fixing heavy duty flange type brass double compression type cable gland
with rubber ring for PVC insulated armoured cable complete with out going tails, insulating
5.4.13 tape etc for following size of cables. Each 278.00 6.00
(I) 3 & 1/2 core 300 Sq. mm
5.5 Aluminium lugs
Supply, installation, testing and commissioning of Solder less crimping type Aluminium
lugs conforming to IS suitable for cable of following size evenly crimped with high pressure
5.5.1 tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an Each 13.00 2.00
approved manner.
Supply, installation, testing and commissioning of Solder less crimping type Aluminium
lugs conforming to IS suitable for cable of following size evenly crimped with high pressure
5.5.2 tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an Each 15.00 20.00
approved manner.
Supply, installation, testing and commissioning of Solderless crimping type Aluminium lugs
conforming to IS suitable for cable of following size evenly crimped with high pressure tool &
5.5.3 connected to switchgear terminals with brass/cadmium plated nut bolts in an approved Each 20.00 80.00
Supply, installation, testing and commissioning of Solderless crimping type Aluminium lugs
conforming to IS suitable for cable of following size evenly crimped with high pressure tool &
5.5.4 connected to switchgear terminals with brass/cadmium plated nut bolts in an approved Each 25.00 40.00
Supply, installation, testing and commissioning of Solderless crimping type Aluminium lugs
conforming to IS suitable for cable of following size evenly crimped with high pressure tool &
5.5.5 connected to switchgear terminals with brass/cadmium plated nut bolts in an approved Each 40.00 30.00
Supply, installation, testing and commissioning of Solderless crimping type Aluminium lugs
conforming to IS suitable for cable of following size evenly crimped with high pressure tool &
5.5.6 connected to switchgear terminals with brass/cadmium plated nut bolts in an approved Each 45.00 54.00
Item no. Item Description Unit Rate Total Qty. Amount
Supply, installation, testing and commissioning of Solderless crimping type Aluminium lugs
conforming to IS suitable for cable of following size evenly crimped with high pressure tool &
5.5.7 connected to switchgear terminals with brass/cadmium plated nut bolts in an approved Each 61.00 24.00
Supply, installation, testing and commissioning of Solderless crimping type Aluminium lugs
conforming to IS suitable for cable of following size evenly crimped with high pressure tool &
5.5.8 connected to switchgear terminals with brass/cadmium plated nut bolts in an approved Each 80.00 2.00
Supply, installation, testing and commissioning of Solderless crimping type Aluminium lugs
conforming to IS suitable for cable of following size evenly crimped with high pressure tool &
5.5.9 connected to switchgear terminals with brass/cadmium plated nut bolts in an approved Each 85.00 116.00
Supply, installation, testing and commissioning of Solderless crimping type Aluminium lugs
conforming to IS suitable for cable of following size evenly crimped with high pressure tool &
5.5.10 connected to switchgear terminals with brass/cadmium plated nut bolts in an approved Each 98.00 30.00
5.6 Copper lugs
Supply, installation, testing and commissioning of Solder less crimping type Copper lugs
conforming to IS suitable for cable of following size evenly crimped with high pressure tool &
5.6.1 connected to switchgear terminals with brass/cadmium plated nut bolts in an approved Each 8.00 544.00
Supply, installation, testing and commissioning of Solder less crimping type Copper lugs
conforming to IS suitable for cable of following size evenly crimped with high pressure tool &
5.6.2 connected to switchgear terminals with brass/cadmium plated nut bolts in an approved Each 10.00 270.00
Supply, installation, testing and commissioning of Solder less crimping type Copper lugs
conforming to IS suitable for cable of following size evenly crimped with high pressure tool &
5.6.3 connected to switchgear terminals with brass/cadmium plated nut bolts in an approved Each 12.00 40.00
Sub Total 5.....
Item no. Item Description Unit Rate Total Qty. Amount
Perforated type cable tray
Providing and fixing approved make Perforated C type cable tray. Made from sheet steel.
The cable tray should be single or double bended as per required and as per IS 2062/1079
and shall be coated with hot dip galvanizing as per IS 2629/4759. with max 17.5%
perforation with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc.
6.1 erection with necessary support( included) as per Specification and as per instruction of Rmt. 357.00 12.00
engineer in charge..
(2) 100 X 50 X 1.6 mm Thick
Providing and fixing approved make Perforated C type cable tray. Made from sheet steel.
The cable tray should be single or double bended as per required and as per IS 2062/1079
and shall be coated with hot dip galvanizing as per IS 2629/4759. with max 17.5%
perforation with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc.
6.2 erection with necessary support( included) as per Specification and as per instruction of Rmt. 420.00 RO
engineer in charge..
(3) 150 X 50 X 1.6 mm Thick
Providing and fixing approved make Perforated C type cable tray. Made from sheet steel.
The cable tray should be single or double bended as per required and as per IS 2062/1079
and shall be coated with hot dip galvanizing as per IS 2629/4759. with max 17.5%
perforation with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc.
6.3 erection with necessary support( included) as per Specification and as per instruction of Rmt. 616.00 190.00
engineer in charge.
(5) 300 X 50 X 2.0 mm Thick
Providing and fixing approved make Perforated C type cable tray. Made from sheet steel.
The cable tray should be single or double bended as per required and as per IS 2062/1079
and shall be coated with hot dip galvanizing as per IS 2629/4759. with max 17.5%
perforation with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc.
6.4 erection with necessary support( included) as per Specification and as per instruction of Rmt. 794.00 18.00
engineer in charge.
(6) 450 X 50 X 2.0 mm Thick
Providing and fixing approved make 'T' Junction for Perforated C type cable tray. Made
from sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated
with hot dip galvanizing as per IS 2629/4759. with max 17.5% perforation with coupler plate
/ Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as
6.4 per Specification and as per instruction of engineer in charge of following size Each 158.00 RO
(2) 100 X 50 X 1.6 mm Thick
Item no. Item Description Unit Rate Total Qty. Amount
Providing and fixing approved make 'T' Junction for Perforated C type cable tray. Made
from sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated
with hot dip galvanizing as per IS 2629/4759. with max 17.5% perforation with coupler plate
/ Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as
6.5 per Specification and as per instruction of engineer in charge of following size Each 183.00 RO
(3) 150 X 50 X 1.6 mm Thick ' T' Junction
Providing and fixing approved make 'T' Junction for Perforated C type cable tray. Made
from sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated
with hot dip galvanizing as per IS 2629/4759. with max 17.5% perforation with coupler plate
/ Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as
6.6 per Specification and as per instruction of engineer in charge of following size Each 289.00 RO
(5) 300 X 50 X 2.0 mm Thick ' T' Junction
Providing and fixing approved make 'T' Junction for Perforated C type cable tray. Made
from sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated
with hot dip galvanizing as per IS 2629/4759. with max 17.5% perforation with coupler plate
/ Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as
6.7 per Specification and as per instruction of engineer in charge of following size Each 544.00 RO
(6) 450 X 50 X 2.0 mm Thick
Providing and fixing approved make '90° Elbow' for Perforated C type cable tray. Made
from sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated
with hot dip galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI
6.7 hardware like nut - bolt and washers etc. erected on existing support as per Specification Each 115.00 4.00
and as per instruction of engineer in charge..
(2)100 X 50 X 1.6 mm Thick 90° Elbow
Providing and fixing approved make '90° Elbow' for Perforated C type cable tray. Made
from sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated
with hot dip galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI
6.8 hardware like nut - bolt and washers etc. erected on existing support as per Specification Each 162.00 RO
and as per instruction of engineer in charge..
(3)150 X 50 X 1.6 mm Thick 90° Elbow
Providing and fixing approved make '90° Elbow' for Perforated C type cable tray. Made
from sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated
with hot dip galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI
6.9 hardware like nut - bolt and washers etc. erected on existing support as per Specification Each 243.00 10.00
and as per instruction of engineer in charge..
(5) 300 X 50 X 2.0 mm Thick 90° Elbow
Item no. Item Description Unit Rate Total Qty. Amount
Providing and fixing approved make '90° Elbow' for Perforated C type cable tray. Made
from sheet steel. The Junction should be bended as per IS 2062/1079 and shall be coated
with hot dip galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI
6.10 hardware like nut - bolt and washers etc. erected on existing support as per Specification Each 442.00 3.00
and as per instruction of engineer in charge..
(6) 450 X 50 X 2.0 mm Thick 90° Elbow
Providing and fixing approved make 'Cross over Junction' for Perforated C type cable
tray. Made from sheet steel. The Junction should be bended as per IS 2062/1079 and shall
be coated with hot dip galvanizing as per IS 2629/4759. with max 17.5% perforation with
6.11 coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on Each 213.00 RO
existing support as per Specification and as per instruction of engineer in charge..
(2) 100 X 50 X 1.6 mm Thick Cross Junction
Providing and fixing approved make 'Cross over Junction' for Perforated C type cable
tray. Made from sheet steel. The Junction should be bended as per IS 2062/1079 and shall
be coated with hot dip galvanizing as per IS 2629/4759. with max 17.5% perforation with
6.12 coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on Each 242.00 RO
existing support as per Specification and as per instruction of engineer in charge..
(3) 150 X 50 X 1.6 mm Thick Cross Junction
Providing and fixing approved make 'Cross over Junction' for Perforated C type cable
tray. Made from sheet steel. The Junction should be bended as per IS 2062/1079 and shall
be coated with hot dip galvanizing as per IS 2629/4759. with max 17.5% perforation with
6.13 coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on Each 370.00 RO
existing support as per Specification and as per instruction of engineer in charge..
(5) 300 X 50 X 2.0mm Thick Cross Junction
Ladder type cable tray
Providing and fixing approved make Ladder type cable tray. Made from M.S sheet. The
cable tray should be bended as per IS 2062/1079 shall be fabricated of double bended
channel section longitudinal members with single bended Channel section. Rungs of
members welded to the base of the longitudinal members at 250 mm c/c spacing . as per
6.14 IS and shall be coated with hot dip galvanizing as per IS 2629/4759. with coupler plate / Mtr. 518.00 121.00
Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as
per Specification and as per instruction of engineer in charge..
(8) 150 X 100 X 1.6 mm Thick
Item no. Item Description Unit Rate Total Qty. Amount
Providing and fixing approved make Ladder type cable tray. Made from M.S sheet. The
cable tray should be bended as per IS 2062/1079 shall be fabricated of double bended
channel section longitudinal members with single bended Channel section. Rungs of
members welded to the base of the longitudinal members at 250 mm c/c spacing . as per
6.15 IS and shall be coated with hot dip galvanizing as per IS 2629/4759. with coupler plate / Mtr. 530.00 RO
Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as
per Specification and as per instruction of engineer in charge..
(9) 200 X 100 X 1.6 mm Thick
Providing and fixing approved make Ladder type cable tray. Made from M.S sheet. The
cable tray should be bended as per IS 2062/1079 shall be fabricated of double bended
channel section longitudinal members with single bended Channel section. Rungs of
members welded to the base of the longitudinal members at 250 mm c/c spacing . as per
6.16 IS and shall be coated with hot dip galvanizing as per IS 2629/4759. with coupler plate / Mtr. 551.00 69.00
Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as
per Specification and as per instruction of engineer in charge..
(10) 300 X 100 X 2.0 mm Thick
Providing and fixing approved make Ladder type cable tray. Made from M.S sheet. The
cable tray should be bended as per IS 2062/1079 shall be fabricated of double bended
channel section longitudinal members with single bended Channel section. Rungs of
members welded to the base of the longitudinal members at 250 mm c/c spacing . as per
6.17 IS and shall be coated with hot dip galvanizing as per IS 2629/4759. with coupler plate / Mtr. 658.00 RO
Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as
per Specification and as per instruction of engineer in charge..
(12) 500 X 100 X 2.0 mm Thick
Providing and fixing approved make Ladder type cable tray. Made from M.S sheet. The
cable tray should be bended as per IS 2062/1079 shall be fabricated of double bended
channel section longitudinal members with single bended Channel section. Rungs of
members welded to the base of the longitudinal members at 250 mm c/c spacing . as per
6.18 IS and shall be coated with hot dip galvanizing as per IS 2629/4759. with coupler plate / Mtr. 688.00 184.00
Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as
per Specification and as per instruction of engineer in charge..
(13) 600 X 100 X 2.0 mm Thick
Providing and fixing approved make Ladder type cable tray. Made from M.S sheet. The
cable tray should be bended as per IS 2062/1079 shall be fabricated of double bended
channel section longitudinal members with single bended Channel section. Rungs of
members welded to the base of the longitudinal members at 250 mm c/c spacing . as per
6.19 IS and shall be coated with hot dip galvanizing as per IS 2629/4759. with coupler plate / Mtr. 794.00 104.00
Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as
per Specification and as per instruction of engineer in charge..
(15) 800 X 100 X 2.0 mm Thick
Item no. Item Description Unit Rate Total Qty. Amount
Providing and fixing approved make 'T' Junction for ladder type cable tray. Made from
M.S sheet steel. The Junction should be bended as per IS 2062/1079. with coupler plate /
Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as
6.20 per Specification and as per instruction of engineer in charge.. Each 619.00 RO
(8) 150 X 100 X 1.5 mm Thick 'T' Junction
Providing and fixing approved make 'T' Junction for ladder type cable tray. Made from
M.S sheet steel. The Junction should be bended as per IS 2062/1079. with coupler plate /
Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as
6.21 per Specification and as per instruction of engineer in charge.. Each 653.00 RO
(9) 200 X 100 X 1.5 mm Thick 'T' Junction
Providing and fixing approved make 'T' Junction for ladder type cable tray. Made from
M.S sheet steel. The Junction should be bended as per IS 2062/1079. with coupler plate /
Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as
6.22 per Specification and as per instruction of engineer in charge.. Each 700.00 RO
(10) 300 X 100 X 2.0 mm Thick 'T' Junction
Providing and fixing approved make 'T' Junction for ladder type cable tray. Made from
M.S sheet steel. The Junction should be bended as per IS 2062/1079. with coupler plate /
Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as
6.23 per Specification and as per instruction of engineer in charge.. Each 967.00 RO
(12) 500 X 100 X 2.0 mm Thick 'T' Junction
Providing and fixing approved make 'T' Junction for ladder type cable tray. Made from
M.S sheet steel. The Junction should be bended as per IS 2062/1079. with coupler plate /
Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as
6.24 per Specification and as per instruction of engineer in charge.. Each 1,077.00 RO
(13) 600 X 100 X 2.0 mm Thick 'T' Junction
Providing and fixing approved make 'T' Junction for ladder type cable tray. Made from
M.S sheet steel. The Junction should be bended as per IS 2062/1079. with coupler plate /
Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as
6.25 per Specification and as per instruction of engineer in charge.. Each 1,323.00 RO
(15) 800 X 100 X 2.0 mm Thick 'T' Junction
Providing and fixing approved make '90° Elbow' for ladder type cable tray. Made from
M.S sheet steel. The Junction should be bended as per IS 2062/1079. with coupler plate /
Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as
6.26 per Specification and as per instruction of engineer in charge.. Each 437.00 15.00
(8) 150 X 100 X 1.6 mm Thick
Item no. Item Description Unit Rate Total Qty. Amount
Providing and fixing approved make '90° Elbow' for ladder type cable tray. Made from
M.S sheet steel. The Junction should be bended as per IS 2062/1079. with coupler plate /
Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as
6.27 per Specification and as per instruction of engineer in charge.. Each 467.00 RO
(9) 200 X 100 X 2.0 mm Thick
Providing and fixing approved make '90° Elbow' for ladder type cable tray. Made from
M.S sheet steel. The Junction should be bended as per IS 2062/1079. with coupler plate /
Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as
6.28 per Specification and as per instruction of engineer in charge.. Each 531.00 6.00
(10) 300 X 100 X 2.0 mm Thick
Providing and fixing approved make '90° Elbow' for ladder type cable tray. Made from
M.S sheet steel. The Junction should be bended as per IS 2062/1079. with coupler plate /
Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as
6.29 per Specification and as per instruction of engineer in charge.. Each 721.00 RO
(12) 500 X 100 X 2.0 mm Thick
Providing and fixing approved make '90° Elbow' for ladder type cable tray. Made from
M.S sheet steel. The Junction should be bended as per IS 2062/1079. with coupler plate /
Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as
6.30 per Specification and as per instruction of engineer in charge.. Each 806.00 11.00
(13) 600 X 100 X 2.0 mm Thick
Providing and fixing approved make '90° Elbow' for ladder type cable tray. Made from
M.S sheet steel. The Junction should be bended as per IS 2062/1079. with coupler plate /
Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as
6.31 per Specification and as per instruction of engineer in charge.. Each 976.00 6.00
(15) 800 X 100 X 2.0 mm Thick
Providing and fixing approved make 'Cross over Junction' for ladder type cable tray.
Made from sheet steel. The Junction should be bended as per IS 2062/1079 and shall be
coated with hot dip galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI
6.32 hardware like nut - bolt and washers etc. erected on existing support as per Specification Each 729.00 RO
and as per instruction of engineer in charge..
(8) 150 X 100 X 1.6 mm Thick
Item no. Item Description Unit Rate Total Qty. Amount
Providing and fixing approved make 'Cross over Junction' for ladder type cable tray.
Made from sheet steel. The Junction should be bended as per IS 2062/1079 and shall be
coated with hot dip galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI
6.33 hardware like nut - bolt and washers etc. erected on existing support as per Specification Each 759.00 RO
and as per instruction of engineer in charge..
(9) 200 X 100 X 2.0 mm Thick
Providing and fixing approved make 'Cross over Junction' for ladder type cable tray.
Made from sheet steel. The Junction should be bended as per IS 2062/1079 and shall be
coated with hot dip galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI
6.34 hardware like nut - bolt and washers etc. erected on existing support as per Specification Each 823.00 RO
and as per instruction of engineer in charge..
(10) 300 X 100 X 2.0 mm Thick
Providing and fixing approved make 'Cross over Junction' for ladder type cable tray.
Made from sheet steel. The Junction should be bended as per IS 2062/1079 and shall be
coated with hot dip galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI
6.35 hardware like nut - bolt and washers etc. erected on existing support as per Specification Each 1,069.00 RO
and as per instruction of engineer in charge..
(12) 500 X 100 X 2.0 mm Thick
Providing and fixing approved make 'Cross over Junction' for ladder type cable tray.
Made from sheet steel. The Junction should be bended as per IS 2062/1079 and shall be
coated with hot dip galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI
6.36 hardware like nut - bolt and washers etc. erected on existing support as per Specification Each 1,174.00 RO
and as per instruction of engineer in charge..
(13) 600 X 100 X 2.0 mm Thick
Providing and fixing approved make 'Cross over Junction' for ladder type cable tray.
Made from sheet steel. The Junction should be bended as per IS 2062/1079 and shall be
coated with hot dip galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI
6.37 hardware like nut - bolt and washers etc. erected on existing support as per Specification Each 1,416.00 RO
and as per instruction of engineer in charge..
(15) 800 X 100 X 2.0 mm Thick
Providing , erecting , fabricating the M.S. structure as per requirement on site incorporating
proper size of M.S. angles,square,round, flats, bars, channels, sections complete with
6.38 cutting, welding, grinding & finishing duly painted with one coat of red oxide with erection on Kg. 77.00 150.60
site as per direction of engineer in charge with necessary grouting, cementing, plastering &
finishing complete.
Sub Total 6.....
7 INTERNAL WIRING
Item no. Item Description Unit Rate Total Qty. Amount
Point wiring for Tissino / Modular secondary light point with 2-1.5 sq.mm & earth
wire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade ZHFR/ HRFR PVC
insulated multi strand copper wires, in below type of pipe to be erected complete with earth
continuity and necessary connection with primary light with accessories erected on Metal /
PVC / wooden box covered with 3 mm thick PC(Polycarbonate) / Acrylic sheet for open /
concealed wiring. with necessary Lamp holder / ceiling rose / H.D.Connector as directed.
7.1 (f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling Pt. 208.95 737.00
Note:- Maximum up to 6 mtrs length, excess will be considered as Mains for
Secondary Point.
NOTE:1. For use of ZHFR/HRFR Copper wires in place of FRLS PVC wires add 5% in
Item of Point wiring Item No 1-1-1 to 1-2-6 & 1-5-1 & 1-5-2.
Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both
are of ISI marked 1.1 KV grade ZHFR/ HRFR PVC insulated multi strand copper wires up to
10 mtr length , in below type of pipe erected with 6A Modular type switch / bell push &
accessories and earth continuity of following type, erected on PVC / Metallic/Wooden box,
single mounting base frame covered with textured/metallic/white front plate modules
erected on / in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose /
7.2 H.D.Connector as directed. Pt. 605.85 1021.00
(f) with medium class Rigid PVC pipe and accessories erected concealed in
wall/ceiling complete(cat lll)
NOTE:1. For use of ZHFR/HRFR Copper wires in place of FRLS PVC wires add 5% in
Item of Point wiring Item No 1-1-1 to 1-2-6 & 1-5-1 & 1-5-2.
Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of
.ISI marked 1.1 KV Grade ZHFR/ HRFR PVC insulated multi strand copper wires up to
mtr length, in below type of pipe erected with 6A Modular type switch and hum free EME
step type electronic fan regulator mounted and accessories with earth continuity of
following type erected on PVC / Metallic/Wooden box, single mounting base frame covered
with textured/metallic/white front plate modules erected on / in wall / ceiling as per pipe
7.3 erected. with necessary ceiling rose / H.D.Connector as directed. Pt. 841.05 290.00
(f) with medium class Rigid PVC pipe and accessories erected concealed in
wall/ceiling complete(cat III)
NOTE:1. For use of ZHFR/HRFR Copper wires in place of FRLS PVC wires add 5% in
Item of Point wiring Item No 1-1-1 to 1-2-6 & 1-5-1 & 1-5-2.
Item no. Item Description Unit Rate Total Qty. Amount
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade ZHFR/ HRFR PVC insulated multi strand copper wires up to 10 mtr
length, in below type of pipe erected complete with Modular type switch & 5 pin Plug
erected on PVC / Metallic/Wooden box covered with appropriate front plate modules erected
on / in wall / ceiling as per pipe erected with following type of accessories.
7.4 [I] For 6A Plug and 6 a switch with 2-1.5 sq.mm Cu. Wire from nearby Pt. 636.30 910.00
switchboard/mcb db board
(f) with medium class Rigid PVC pipe and accessories erected concealed in
wall/ceiling complete (cat III)
NOTE:1. For use of ZHFR/HRFR Copper wires in place of FRLS PVC wires add 5% in
Item of Point wiring Item No 1-1-1 to 1-2-6 & 1-5-1 & 1-5-2.
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade ZHFR/ HRFR PVC insulated multi strand copper wires up to 10 mtr
length, in below type of pipe erected complete with Modular type switch & 5 pin Plug
erected on PVC / Metallic/Wooden box covered with appropriate front plate modules erected
on / in wall / ceiling as per pipe erected with following type of accessories.
[II] For 16A Plug and 16 amp switch with 2-2.5 sq.mm Cu. Wire from mcb db board.
(f) with medium class Rigid PVC pipe and accessories erected concealed in
wall/ceiling complete (cat III)
NOTE:1. For use of ZHFR/HRFR Copper wires in place of FRLS PVC wires add 5% in
Item of Point wiring Item No 1-1-1 to 1-2-6 & 1-5-1 & 1-5-2.
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade ZHFR/ HRFR PVC insulated multi strand copper wires up to 10 mtr
length, in below type of pipe erected complete with Modular type switch & 5 pin Plug
erected on PVC / Metallic/Wooden box covered with appropriate front plate modules erected
on / in wall / ceiling as per pipe erected with following type of accessories.
7.6 [III] For 16A Plug and 16 amp switch with 2-4 sq.mm Cu. Wire with 2.5 sq.mm ( green) Pt. 1,087.80 268.00
earthing wire from mcb d b board.
(f) with medium class Rigid PVC pipe and accessories erected concealed in
wall/ceiling complete (cat III)
NOTE:1. For use of ZHFR/HRFR Copper wires in place of FRLS PVC wires add 5% in
Item of Point wiring Item No 1-1-1 to 1-2-6 & 1-5-1 & 1-5-2.
Point wiring for on board Looped Plug with 6A Modular type switch & 5 pin socket erected
on PVC / Metallic/Wooden box, single mounting base frame covered with textured /
metallic/white front plate modules erected on / in wall / ceiling with following type
7.7 accessories Pt. 321.30 664.00
NOTE:1. For use of ZHFR/HRFR Copper wires in place of FRLS PVC wires add 5% in
Item of Point wiring Item No 1-1-1 to 1-2-6 & 1-5-1 & 1-5-2.
Item no. Item Description Unit Rate Total Qty. Amount
Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm & earth wire of
sq.mm (green) both are of .ISI marked 1.1 KV grade ZHFR/ HRFR PVC insulated multi
strand copper wires erected in below type of pipe with 6A Modular type switches and
following type of accessories erected on PVC / Metallic/Wooden box, single mounting base
frame covered with textured / metallic/white front plate modules erected on / in wall / ceiling
as per pipe erected. with necessary batten/angle holder or ceiling rose or H.D.Connector as
(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling
complete(cat III)
NOTE:1. For use of ZHFR/HRFR Copper wires in place of FRLS PVC wires add 5% in
Item of Point wiring Item No 1-1-1 to 1-2-6 & 1-5-1 & 1-5-2.
Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded
Copper conductor wire in following type of pipe to be erected concealed in /flushed on
wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green
7.9 colour for earth continuity of following size Rmt. 78.00 6045.00
(A) With medium class Rigid PVC pipe and accessories
(a) 2 wire 1.5 sq. mm
Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded
Copper conductor wire in following type of pipe to be erected concealed in /flushed on
wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green
7.10 colour for earth continuity of following size Rmt. 103.00 36595.00
(A) With medium class Rigid PVC pipe and accessories
(b) 2 wire 2.5 sq. mm
providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded
Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq.
mm copper conductor FRLS PVC insulated stranded wire of green colour for earth
7.11 continuity of following size Rmt. 111.00 8663.00
(A) with medium class Rigid PVC pipe and accessories
(a) 2 wire 4 sq. mm
providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded
Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq.
mm copper conductor FRLS PVC insulated stranded wire of green colour for earth
7.12 continuity of following size Rmt. 183.00 9240.00
(A) with medium class Rigid PVC pipe and accessories
(b) 2 wire 6 sq. mm
providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded
Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq.
mm copper conductor FRLS PVC insulated stranded wire of green colour for earth
7.13 continuity of following size Rmt. 293.00 20.00
(A) with medium class Rigid PVC pipe and accessories
(c) 2 wire 10 sq. mm
(use earth wire of 4 sq.mm )
Item no. Item Description Unit Rate Total Qty. Amount
providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded
Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq.
mm copper conductor FRLS PVC insulated stranded wire of green colour for earth
7.14 continuity of following size Rmt. 323.00 468.00
(A) with medium class Rigid PVC pipe and accessories
(h) 4 wire 6 sq. mm
providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded
Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq.
mm copper conductor FRLS PVC insulated stranded wire of green colour for earth
7.15 continuity of following size Rmt. 527.00 RO
(A) with medium class Rigid PVC pipe and accessories
(i) 4 wire 10 sq. mm
(use earth wire of 4 sq.mm )
Providing & erecting Switch board for Computer or electric apparatus consisting of
following modular type accessories mounted with PVC / Metallic concealed/open box with
single mounting base frame covered with textured/metallic /white front plate,modules
erected with necessary connections as directed
7.16 1 no. 6A/16A universal plug-switch combined. Pt. 1,122.00 44.00
3 nos. 6A Switch
3 nos. 6A 5 pin Plug
For Modular Type accessories Cat. III
SITC of following type of Modular Type accessories mounted with PVC / metallic/Wooden
box, single mounting base frame covered with textured / metallic/white front plate , modules
7.17 erected with necessary connections as per site situation directed by Engineer In charge. Each 395.00 290.00
(5) Electronic hum Free four or more steps EME Fan regulator (cat III)
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded,
annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC -
erected in existing pipe of following size (Specifically for control panel, relays, power
7.18 switchgears, motor starters & control wiring) with required size of copper lugs, nuts and bolts Mtr. 373.00 100.00
(i) One wire 35.00 sq. mm
Providing following type of Modular Type Accessories mounted with PVC / metallic/Wooden
box, single mounting base frame covered with textured / metallic/white front plate , modules
7.19 erected with necessary connections as per site situation directed by Engineer In charge. Each 159.00 148.00
(4) TV Co-axial Socket outlet
SITC of following type of Modular Type accessories mounted with PVC / metallic/Wooden
box, single mounting base frame covered with textured / metallic/white front plate , modules
7.20 erected with necessary connections as per site situation directed by Engineer In charge. Each 25.00 100.00
(7) Blank Plate Single (cat III)
Item no. Item Description Unit Rate Total Qty. Amount
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete
to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes
fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as
7.21 directed Each 33.00 10038.00
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete
to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes
fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as
7.22 directed Each 54.00 468.00
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete
to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes
fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as
7.23 directed Each 67.00 50.00
Providing following type of Modular Type Accessories mounted with PVC / metallic/Wooden
box, single mounting base frame covered with textured / metallic/white front plate , modules
7.24 erected with necessary connections as per site situation directed by Engineer In charge. Each 64.00 505.00
Batten Holder/Angle Holder with modular frame with metal ring.Cat-III
Sub Total 7.....
8 INDOOR LIGHT FIXURE
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt
assembled on single MCPCB, with housing used as a heat sink shall be made of thick
sheet Steel conforming to IS: 513/CRCA/ aluminium die cast powder coated and high U.V.
& corrosion resistance with diffuser with company mark/name 160V to 270V, Power Factor
more than 0.95, THD < 15%,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges
of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.)
(A) Tube Light with integral driver
(iii) 18-20 Watts, Surge - 2KV,IP-20, conventional 4 feet Cat-III
Item no. Item Description Unit Rate Total Qty. Amount
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt
assembled on single MCPCB, with housing used as a heat sink shall be made of thick
sheet Steel conforming to IS: 513/CRCA/ aluminium die cast powder coated and high U.V.
& corrosion resistance with diffuser with company mark/name 160V to 270V, Power Factor
more than 0.95, THD < 15%,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges
of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.)
(A) Tube Light with integral driver
(v) 36-40 Watts, Surge-2 KV, IP-20, conventional 4 feet
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt
assembled on single MCPCB, with housing used as a heat sink shall be made of thick
sheet Steel conforming to IS: 513/CRCA/aluminium pressure die cast powder coated and
high U.V. & corrosion resistance with diffuser housed in aluminium casted body with
company mark/name
160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges
of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.)
(H) Mirror Light 9 Watts, wall mounted minimum 1 feet long
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt
assembled on single MCPCB, with housing used as a heat sink shall be made of thick
sheet Steel conforming to IS: 513/CRCA/aluminium pressure die cast powder coated and
high U.V. & corrosion resistance with diffuser housed in aluminium casted body with
company mark/name
160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
8.4 LED driver efficiency > 85 % Each 751.00 10.00
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges
of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.)
(A) Square/ Circular shaped Surface/Recessed Mount Downlight with provision for
spring loaded mounting clips complete.IP20
(iv) 22-24 watts, Surge-2 KV
Item no. Item Description Unit Rate Total Qty. Amount
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt
assembled on single MCPCB, with housing used as a heat sink shall be made of thick
sheet Steel conforming to IS: 513/CRCA/aluminium pressure die cast powder coated and
high U.V. & corrosion resistance with diffuser housed in aluminium casted body with
company mark/name
160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
8.5 LED driver efficiency > 85 % Each 584.00 275.00
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges
of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.)
(A) Square/ Circular shaped Surface/Recessed Mount Downlight with provision for
spring loaded mounting clips complete.IP20
(iii) 16-20 watts, Surge-2 kV Cat-III
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt
assembled on single MCPCB, with housing used as a heat sink shall be made of thick
sheet Steel conforming to IS: 513/CRCA/aluminium pressure die cast powder coated and
high U.V. & corrosion resistance with diffuser housed in aluminium casted body with
company mark/name
160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
8.6 LED driver efficiency > 85 % Each 423.00 723.00
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges
of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.)
(A) Square/ Circular shaped Surface/Recessed Mount Downlight with provision for
spring loaded mounting clips complete.IP20
(ii) 11-15 watts, Surge-2 KV Cat-III
Supplying and erecting LED street light / Flood light fittings with High power White LEDs
wattage of 3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses,
with toughened glass with company mark/name engraved or embossed 160 to 270 V,Power
Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45,
Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.( fittings required LM-79
8.7 & LM-80 certificates)(NOTE: Below description have shown ranges of Wattage capacity of Each 8,120.00 27.00
LED fittings.The Engineer incharge may select any wattage capacity between the ranges
(B) Flood Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC
line supply with over-voltage protection.
(vi) above 160 to 200 watts
Item no. Item Description Unit Rate Total Qty. Amount
Providing & erecting Approved make Power Saving 45 - 50 Watt Ceiling Fan with double
8.8 ball bearing ISI mark with Condenser 230 volt A.C. 50 Hz 1200 mm sweep complete Each 1,929.00 290.00
having 3blades with aluminium blades with , canopy & 30 cm. down rod erected with
earthing.(Make shall be approved by Engineer in charge))
Supplying & erecting approved make low noise decorative exhaust fan having square frame
8.9 ABS body with inbuilt lowers & square frame. Each 1,687.00 2.00
250mm with 1350 RPM Cat.II
8.10 Providing suitable M.S. louver shutter of the Exhaust fan. Each 365.00 2.00
Wall bracket fan:
Supplying and erecting approved make oscillating type bracket fan A.C. 23OV. 50cy/s
400/450 mm sweep wall mounted with height adjustment and rotary tilting device complete
8.11 with guard, flexible Core plug top complete erected with lead wires as directed. Each 2,509.00 2.00
Sub Total 8.....
Providing and erecting required size HOT deep Galvanised iron strip for earthing of H.T.
OCB/ ACB/ Transformer LT panel board, Motors etc. using proper clamp.
Providing and erecting required size Copper strip for earthing of H.T. OCB / ACB/
Transformer, LT panel board, Motors etc. using copper clamp.
9.3 Providing and erecting Annealed bare Copper wire 4.064mm to 1.626mm. Kg. 787.00 297.54
9.4 Providing and erecting HOT deep Galvanised iron strip/wire 4.064mm to 1.626mm. Kg. 77.00 -
Supplying & erecting earth pit of minimum bore dia.150mm size approved make Earthing
Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free
hot dipped G.I.Pipes having Outer pipe dia of 50mm having 80-200 Micron galvanising,
Inner pipe dia of 25 mm having 200-250 Micron galvanising, connection terminal dia of
12mm with constant ohmic value surrounded by highly conductive compound with high
charge dissipation suitable for following type of applications with chamber and heavy duty
cover. (A)(approved make OEM has to submit test certificate including value of earth
resistance of installation duly stamped and signed by agency and officer Incharge has to
ensure the value of earthing resistane mentioned in test Certificate) & having back filling
compound of (B) Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm / meter testing as
9.5 per IEC 62561-2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2%(C) Each 8,551.00 59.00
Back fill Compound :- Earthing compound should be capable to retain moisture for long
time Necessary test report must be submitted by Agency.
(c) For Electrical Installation covering Transformer Neutrals, Lightning arrester
Earthing, A.C.Plant & Sensitive Computer System(like Automation, SCADA) i.e
independent Earthing in normal soil.
Length of Pipe : 3.00 mtrs
Back filling Compound :2 nos Bags of 25 Kg.
Sub Total 9......
Item no. Item Description Unit Rate Total Qty. Amount
Supplying and erecting approved make online Un-interruptible Power Supply system
comprising flat cum-boost charger with IGBT base rectifier & Inverter & sealed maintenance
free SMF batteries. The charger having operating capacity for input 160-270V AC & inverter
having output 230V,50 Hz Ac with 0.8 load power factor with battery, over/under voltage
10.1 output with over load & short circuit protection equipment. The system housed in CRC sheet Each 1,28,815.00 2.00
duly powder coated paint with following power backup.with MS painted batteries stand, 10%
Overload capacity for momentary load.
(D) 5KVA with 1Hr Backup
Supplying and erecting approved make online Un-interruptible Power Supply system
comprising flat cum-boost charger with IGBT base rectifier & Inverter & sealed maintenance
free SMF batteries. The charger having operating capacity for input 160-270V AC & inverter
having output 230V,50 Hz Ac with 0.8 load power factor with battery, over/under voltage
10.2 output with over load & short circuit protection equipment. The system housed in CRC sheet Each 12,26,283.00 1.00
duly powder coated paint with following power backup.with MS painted batteries stand, 10%
Overload capacity for momentary load.
(L) 40 KVA 3 - phase with 1Hr Backup
Sub Total 10......
11 SAFETY ITEMS
Providing and erecting metallic vitrified danger notice board as per language suggested
11.1 by engineer incharge for MEDIUM VOLTAGE installation to be erected as per IS-2551. Each 69.00 10.00
Providing and erecting metallic vitrified danger notice board as per language suggested
11.2 by engineer incharge for HIGH VOLTAGE installation to be erected as per IS.-2551. Each 81.00 1.00
Providing and fixing printed instruction chart both in English and Gujarati and duly
11.3 framed with front glasses, for treatment of person suffering from Electric shock with Each 129.00 1.00
minimum 50" diagonally size.
11.4 Providing pair of rubber hand gloves suitable for working on 11 kV/22 kV supply. Each 212.00 1.00
Supplying rubber matting of following thickness as per IS:15652/IEC
Supplying stand first AID box with antiseptic cream, medicine for use on wounds due burn,
crepe bandage, gauge bandage, medicated ready to use bandage (Band-aid) adhesive tape
11.6 for medicinal user, Scissors, anti-septic solution (Savlon or similar) etc. (All above contents Each 297.00 5.00
shall be of standard makes)
Supplying FIRE bucket round bottom of 9 litres capacity made out of 24 gauge G.I. sheet
11.7 with extra handle at bottom duly painted white inside and Red out side with FIRE mark, Each 212.00 1.00
filled with dry-sand and kept on existing stand provided or hung on wall hook.
Supplying and erecting floor mounting stand for keeping four nos. of FIRE buckets
comprising 1500 mm in length, 900 mm height frame made out of 30mm X30 mm X 4 mm
11.8 angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat Each 933.00 1.00
of red lead and two coats of approved enamelled silver paint.
Item no. Item Description Unit Rate Total Qty. Amount
Wall hook 22 to 25 cms. projection for keeping fire buckets made out of 15 mm dia. M.S rod
grouted in wall to a depth of minimum 15 cms.
Supplying & erecting D.C.P. type fire extinguisher for following capacity cartridge type with
gun metal cap 150 gram CO2 gas cartridge, powder and brackets confirming to IS
11.10 1985 and complete erected with necessary clamps made from 50 x 6 mm M S Flat with nuts Each 1,696.00 5.00
and bolts grouted in wall complete.
[A] For 5 Kg Capacity
Supply and installtion of expanding firestop foam equivalent to Hilti CP 620 on both sides of
wall, with minimum 2 hours fire rating when tested in accordance with UL 1479/ASTM-E
814, for horizontal openings in floors or slabs made of concrete/ masonry or Gypsum after
passing service lines like cable trays or cables/cable bundles. The expanding foam expands
seven times its volume to fill the cavity at the time of dispensing the material and shall fully
cure within two minutes after dispensing. The product shall be age tested as per Dafstb and
DIBT standards. The product shall provide water tightness when tested for W rating as per
11.11 UL standards and shall carry test certificate for sound insualtion of 50 db when tested in Each 10,643.83 5.00
accordance with ASTM E 90. The product shall carry test certificate for mold resistance
rating of 0 as determined by ASTM G21-96 and shall have a VOC content of approx. 1.3 g/l
as per LEED 2009. The product shall be tested in accordance with IEC 60068-2-57:1999-11
(Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and
VERTEQII for seismic zone 4. The system shall be UL listed & classified. The system shall
be UL & FM approved.
Supply and installation of Fire stop mortar system equivalent to Hilti CP 636 , with minimum
2 hours fire rating when tested in accordance with UL 1479/ASTM-E 814 standards, for
horizontal openings in floors or slabs after passing service lines like cables/cable bundles,
cable trays etc. The mortar shall be a light weight cementitious product and shall carry test
certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part
2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product
shall be age tested as per Dafstb and DIBT standards. The product shall carry test
certificate for mold resistance rating of 0 as determined by ASTM G21-96. The product shall
be age tested as per Dafstb and DIBT standards.The system shall be UL listed. The gaps
around inaccessible or complicated openings shall be sealed with exapnding firestop foam.
Sub Total 11.....
12 EXTERNAL LIGHT FIXTURE AND POLE
PLANT UPLIGHTER
SITC of Plant Uplighter:
System Wattage : 12W LED,Driver Integral : Constant Current,Operating Voltage : 100-
300Vac,Operating Temperature : -15°C~+50°C,Body : Die-cast Aluminium Alloy,Diffuser :
12.1 Clear Toughened Glass,Mounting : Spike / Die-castAluminium BracketFinish : Powder Each 3,445.40 10.00
coated.Light Source : CITIZEN.CRI (Ra) : ≥80.LED Colour Temperature : 3000K.Driver
Power Supply : Integral.Input Voltage : 230-240Vac.Frequency : 50-60 Hz.Power Factor :
THD : <10%.Surge Protection : 4KV.Efficiency : >80%.Beam Angle : 25°.IP66
Item no. Item Description Unit Rate Total Qty. Amount
Supply of approved make frp/grp pole having followiing specifications :
FRP/GRP pole made by centrifugal moulding process using thermoset resin polyester/epoxy
resin system having minimum glass content 45.0%.The pole should be in one pieceand
tapered round in shape,having smooth outside surface finish and should be totally fre from
corrosion as well as non conductive and shock proof. Pole should be provided with
FRP/GRP base bracket dully fabricated from metal(M.S) and dully claded with FRP/GRP
material to avoid any metal exposer and painted with PU paint.Pole should mechanical
properties i.e 1. Specfic gravity (ASTM D 792) 1.3‐1.8 Kg/m3, 2. Glass Content % by weight
(ASTM D 2584) 45.0 ‐55.0%, 3. Water absorption (ASTM D 570)
<0.5%, 4. Tensile Strength(ASTM D 638) 200+/‐50Mpa, 5. Flexural strength (ASTM D 790)
12.2 250+/‐50Mpa, 6. Compressive Strength (ASTM D 695) 200+/‐50MPa, 7. Yeild Each 9,932.00 20.00
Strength(ASTM D638) 250 +/‐50MPa.Pole should be flame retardant as per IS 6746.Resin
used shall be UV resistance and pigmented. Pole should be painted with first coat of epoxy
primer and then two coat of highly weather resistance polyurethen paint to ensure proper
addhesion of the paint.Minimum thickness shall be 80 to 100 micron.Defelection of the pole
shall not exceed more than 10.0 % of the length of the pole for the given load.Pole should
be generally made as per the dimensional data,performance criteria and some
interchagebility features of poles as per the standard ANSI C123.20 latest version of ASTM
D 923/01 including cable termination box with necessory accessories.The size of pole and
type of installation with foundation , Anchor Base & Internal junction box as per the
manufacturer details and site requirement .
Supply of approved make frp/grp pole having followiing specifications :
FRP/GRP pole made by centrifugal moulding process using thermoset resin polyester/epoxy
resin system having minimum glass content 45.0%.The pole should be in one pieceand
tapered round in shape,having smooth outside surface finish and should be totally fre from
corrosion as well as non conductive and shock proof. Pole should be provided with
FRP/GRP base bracket dully fabricated from metal(M.S) and dully claded with FRP/GRP
material to avoid any metal exposer and painted with PU paint.Pole should mechanical
properties i.e 1. Specfic gravity (ASTM D 792) 1.3‐1.8 Kg/m3, 2. Glass Content % by weight
(ASTM D 2584) 45.0 ‐55.0%, 3. Water absorption (ASTM D 570)
<0.5%, 4. Tensile Strength(ASTM D 638) 200+/‐50Mpa, 5. Flexural strength (ASTM D 790)
12.3 250+/‐50Mpa, 6. Compressive Strength (ASTM D 695) 200+/‐50MPa, 7. Yeild Each 15,488.00 5.00
Strength(ASTM D638) 250 +/‐50MPa.Pole should be flame retardant as per IS 6746.Resin
used shall be UV resistance and pigmented. Pole should be painted with first coat of epoxy
primer and then two coat of highly weather resistance polyurethen paint to ensure proper
addhesion of the paint.Minimum thickness shall be 80 to 100 micron.Defelection of the pole
shall not exceed more than 10.0 % of the length of the pole for the given load.Pole should
be generally made as per the dimensional data,performance criteria and some
interchagebility features of poles as per the standard ANSI C123.20 latest version of ASTM
D 923/01 including cable termination box with necessory accessories.The size of pole and
type of installation with foundation , Anchor Base & Internal junction box as per the
manufacturer details and site requirement .
Providing frp/grp
1:2:4 poleconcrete
cement suitable for base plate
foundation mounting
& 70 % PCC from bottom including
excavation for the pole of size 45 x 45 x 100 cm. Deep in below ground level with plinth of
12.4 45 cm x 45 cm (or 45 cm dia x 45 cm) high upper ground level with necessary curing and Each 801.00 25.00
finishing in approved manner.
( for 4 & 6 mtr pole)
Item no. Item Description Unit Rate Total Qty. Amount
Supplying and erecting LED street light / Flood light fittings with High power White LEDs
wattage of 3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses,
with toughened glass with company mark/name engraved or embossed 160 to 270 V,Power
Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45,
Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.( fittings required LM-79
12.5 & LM-80 certificates)(NOTE: Below description have shown ranges of Wattage capacity of Each 2,815.00 20.00
LED fittings.The Engineer incharge may select any wattage capacity between the ranges
shown.)(A) Street Light (IP-65), Surge protection -4KV integral and ,Light must have
440VAC line supply with over-voltage.
(i) above 36 to 48 watts
Note: All lighting fixture colour to be matched with architecture finishes.
Supply, Installation Testing and Commissioning of Street Light:
Supplying and erecting LED street light / Flood light fittings with High power White LEDs
wattage of 3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses,
with toughened glass with company mark/name engraved or embossed 160 to 270 V,Power
12.6 Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45, Each 4,206.00 5.00
Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.( fittings required LM-79
& LM-80 certificates)(NOTE: Below description have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may select any wattage capacity between the ranges
(A) Street Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC
line supply with over-voltage.
Providing and fixing Terminal board of size 5.0 x 127 x 152.4 mm.bakelite sheet with
12.7 suitable brass studs with nuts, washers and clamps of size 25mm x 3mm suitable for pole Nos 145.00 25.00
painted with one coat of red lead paint.
Supplying and erecting Water tight M.S.Box of size 20 x 15 x 15 cm. to erect suitable kitkat
fuse / MCB to be . erected on polished wooden board inside the box with hinged/sliding
12.8 door with rubber rings and erected on pole with suitable pole clamp, all duly painted with Nos 232.00 1.00
one coat of red oxide and two coats of paints. (Cost of Fuse / MCB shall be taken extra)
Providing & erecting approved make street light / wall mounting junction box
compression moulded from SMC (thermoset plastic) vertical sliding cover having locking
12.9 with square head stud loop in / loop out in built terminal suitable for four core cable, Each 610.00 25.00
waterproof of I.P. 54 protected with clamp or bolt nut & earth bolt of following size
Providing FRP/GRP arm bracket of having 15˚ arm with 50 mm OD pipe *5 mm
12.10 thk,1000mm long from pole centre Each 2,165.00 25.00
(A) Single arm bracket
Providing FRP/GRP arm bracket of having 15˚ arm with 50 mm OD pipe *5 mm
12.11 thk,1000mm long from pole centre Each 2,749.00 1.00
(B) Double arm bracket
Item no. Item Description Unit Rate Total Qty. Amount
Supplying and erecting B class Galvanized iron pipe having smooth finished bore of the pipe
on both ends erected nuts and bolts along the pole / wall shaping the pipe as per site
12.12 requirement. Pipe dia as following. Rmt. 247.00 50.00
Painting of street light pole having post top lantern complete with primer with two coats of
Aluminium paint.
Painting of street light pole with bracket complete with two coats of Aluminium paint for
12.14 following size of pole. Nos 213.00 25.00
(A) up to 4 mtr
Painting of street light pole with bracket complete with two coats of Aluminium paint for
12.15 following size of pole. Nos 263.00 5.00
(B) up to 6 mtr.
SITC of Step Light:
System Wattage : 12W LED,Driver Integral : Constant Current,Operating Voltage : 100-
277Vac,Operating Temperature : -15°C~+50°C,Body : Die-Cast Aluminium,Diffuser : Clear
12.16 Acrylic,Gasket : Silicone,Mounting Sleeve : ABS Plastic,Mounting : Wall - Recess,Finish : Nos 1,611.96 20.00
Powder coated,Light Source : NICHIA,CRI (Ra) : ≥80,LED Colour Temperature :
3000K,Driver Power Supply : Integral,Input Voltage : 230-240Vac,Frequency : 50-60
Hz,Power Factor : ≥0.90,THD : <10%,Surge Protection : 2KV / 2.5KV,Efficiency : >85%,IP65
Sub Total 12.....
13 DWC PIPE AND CHAMBER
Providing & laying. R.C.C. Hume pipe for cable to be laid 90 cm. below ground across the
road crossing or on floor with necessary material in an approved manner and making the
13.1 ground as per original. Mtr. 340.00 10.00
Providing & laying. R.C.C. Hume pipe for cable to be laid 90 cm. below ground across the
road crossing or on floor with necessary material in an approved manner and making the
13.2 ground as per original. Mtr. 261.00 50.00
Providing & laying approved make Double walled corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same
13.3 material at required depth in existing trench for laying of cable. below ground / road Mtr. 62.00 100.00
surface for enclosing cable
(A)50 mm outer dia
Providing & laying approved make Double walled corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same
13.4 material at required depth in existing trench for laying of cable. below ground / road Mtr. 73.00 350.00
surface for enclosing cable
(B)63mm outer dia
Item no. Item Description Unit Rate Total Qty. Amount
Providing & laying approved make Double walled corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same
13.5 material at required depth in existing trench for laying of cable. below ground / road Mtr. 136.00 75.00
surface for enclosing cable
(D)120 mm outer dia
Excavating hard Murrum or Metal road by chiselling for preparing pit for poles or earth
plates or for laying pipes & clearing the site by removing debris & making site good.
Sub Total 13.....
SITC of Vertical Air Termination Solid aluminium with Base- 10 mm dia and 1000 mm long.
Air Termination Base tested for conditioning, Ageing Test & Lightning impulse current
14.1 withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per Nos 9,323.00 18.00
6.3 & 6.4 of IEC 62561-1 2017 protocol with MAST 34mm dia 3000 mm long- Cold
SITC of 16mm Dia Aluminium Air termination 3000mm Long with 2 nos SS Clamp Suitable
14.2 for side mounting on wall;Universal cross and T Connector -SS -for 8mm and 16mm dia Nos 5,484.83 -
SITC of 8 mm dia solid Aluminium Conductor for roof top mesh grid and tested as per IEC
62561- 2 conducted in the Govt. accredited thirty party laboratory to meet the requirement
of IS/IEC 62305 with Required Accessories - Aluminium Holding clamp at every 1 mtr
distance, Aluminium/SS cross splicer at every crossing of Alu. conductor, Expansion piece
with connectors at every 20 mtr distance, Aluminium straight Splicer to connect conductors.
14.3 All Accessories should be tested as per IEC 62561-1 2018 Cl. 6.3 for conditioning & Ageing Mtr. 297.00 575.00
Test & 6.4 for Lightning impulse current withstand test: 100 kA of 10/350µs
waveform(Ageing & Electrical test ) conducted in a sequence manner & tested in the Govt.
accredited Third party laboratory to meet the requirements of IS/IEC
SITC of 10 mm MS Round Solid Conductor having smooth surface Should be tested and
use exclusively for lightning protection (Vertical Riser/Down Conductor which shall be
concealed in Column) to meet the requirement of IS IEC 62305 With Accessories - Earthing
stud of dimension SS-75mm OD plate with 10mm dia tail connector used in structural steel
ring earthing system to meet the requirements of IS/IEC 62305. (For Interconnecting the
Column and the Terrace AL Conductor / Strip/Flat), SS Cross Connector to connect Earth
fixing point to vertical raiser/Down conductor, SS Straight Splicer at every 4 Mtr to connect
MS conductor in column, Bonding /Rebar Clamp at every 3 mtr suitable for interconnecting
round conductor with reinforcement inside the concrete for structural earthing system, SS
connector -To connect external conductor 8- 10 mm with earth fixing point. All Accessories
should be tested as per IEC 62561-1 2018 Cl. 6.3 for conditioning & Ageing Test & 6.4 for
Lightning impulse current withstand test: 100 kA of 10/350µs waveform(Ageing & Electrical
conducted in a sequence manner & tested in the Govt. accredited Third party laboratory to
meet the requirements of IS/IEC
Item no. Item Description Unit Rate Total Qty. Amount
SITC of Galvanized Steel Flat 25x6 mm thickness from earth electrode directly in ground as
14.5 required. Zinc coating: 500 g/m square (Approx:70 micron coating) tested and used Mtr. 153.00 437.00
exclusively for lightning protection earthing system and ring equipotential bonding.
SITC of 14.2 mm dia 3 mtr long Earth electrode of High tensile steel electrode with
micron copper bonding & 1 bag of Carbon fill Based environment friendly backfill tested as
per IEC 62561-7 in NABL accredited Laboratory and suitable stainless Steel double sided
14.6 clamp. Eco Friendly rust proof heavy duty weather proof Polyethylene Earth Pit Chamber set 5,933.00 10.00
with following dimensions :254 mm dia (top), 330 mm dia (bottom) & 260 mm (height).
Sub Total 14.....
15 SERVICE WORK
Liasoning work for power supply procurement (New Service/Load Ext./reduction/Shifting)
with Site Visit, Test Report Submission, Meter Connection in T.P.L/U.G.V.C.L. and Also all
necessary work as per site as and when require.
15.1 Single site more than 10 No. of Service Connection. Per Service 1,500.00 67.00
15.2 Liasoning Work of HIgh Rise NOC Job 25,000.00 1.00
Sub Total 15.....
16 RACEWAY/TRUNKING & JUNCTION BOX
Supplying under floor pregalvanised corrosion proof rectangular sheet steel cable trunking
of 1.6 mm thick having with stand point load up to 1.33 Ton & free from seepage of concrete
of screed water with all accessories,Junction Box,Joints as required and demanded by
engineer-incharge and laying/erecting as per OEM guidelines and as per instruction of
16.1 engineer incharge having following size of dimensions and No of compartments (W x D x T) Mtr. 295.00 10.00
[1] 50mm x 25mm x 1.6 mm with One Compartment
Supplying under floor pregalvanised corrosion proof rectangular sheet steel cable trunking
of 1.6 mm thick having with stand point load up to 1.33 Ton & free from seepage of concrete
of screed water with all accessories,Junction Box,Joints as required and demanded by
engineer-incharge and laying/erecting as per OEM guidelines and as per instruction of
16.2 engineer incharge having following size of dimensions and No of compartments (W x D x T) Mtr. 454.00 20.00
[3] 100mm x 25mm x 1.6 mm with one compartment
Supplying under floor pregalvanised corrosion proof rectangular sheet steel cable trunking
of 1.6 mm thick having with stand point load up to 1.33 Ton & free from seepage of concrete
of screed water with all accessories,Junction Box,Joints as required and demanded by
engineer-incharge and laying/erecting as per OEM guidelines and as per instruction of
16.3 engineer incharge having following size of dimensions and No of compartments (W x D x T) Mtr. 965.00 10.00
[4] 225mm x 25mm x 1.6 mm with Three Compartment
Item no. Item Description Unit Rate Total Qty. Amount
Supply, installation, testing and commissioning of following sizes of Floor junction boxes
having Back Box made from hot-dip pre-galvanized 275 GSM zinc coated steel sheet having
specification as per IS277:2003 with base box thickness not less than 1mm. Back Box
formation should be done by assembling sheared and bent modular parts. Lid of the junction
box should be made from 2.5mm thick, epoxy coated steel sheet. Lid formation should be
done by shearing, bending, and welding steel sheet to form 8mm recess to accommodate
floor tile, stone, or carpet. Trap cover screws should be made from stainless steel for extra
protection. Height adjustable support pillars should be made from high pressure die cast
16.4 aluminum and provided with adjustable height from 55mm to 70mm. Modular side wall of the Each 1,923.27 5.00
box should be provided with knockout suitable to accommodate raceway of 25mm and
mm height. The junction box should be having IP rating of 20 with temperature handling
capacity of -5˚ c to 60˚ c. The junction box should be able to bear load up-to 2.5 Ton/m2 as
per IEC 61084-1:2017 & 61084-2-2:2017 standards. Earth wire connector should be
provided in all the boxes. Throwaway lid should be provided free of cost to protect from
water seepage during cementing/screeding process at site. Size - 150x150x55-70mm
Supply, installation, testing and commissioning of following sizes of Cross over junction
boxes having Back Box made from hot-dip pre-galvanized 275 GSM zinc coated steel sheet
having specification as per IS277:2003 with base box thickness not less than 1mm. Back
Box formation should be done by assembling sheared and bent modular parts. Lid of the
junction box should be made from 2.5mm thick, epoxy coated steel sheet. Lid formation
should be done by shearing, bending, and welding steel sheet to form 8mm recess to
accommodate floor tile, stone, or carpet. Trap cover screws should be made from stainless
steel for extra protection. Height adjustable support pillars should be made from high
pressure die cast aluminum and provided with adjustable height from 55mm to 70mm.
16.5 Modular side wall of the box should be provided with knockout suitable to accommodate Each 2,825.23 5.00
raceway of 25mm and 38 mm height. The junction box should be having IP rating of 20 with
temperature handling capacity of -5˚ c to 60˚ c. The junction box should be able to bear load
up-to 2.5 Ton/m2 as per IEC 61084-1:2017 & 61084-2-2:2017 standards. Crossover junction
box with epoxy powder coated flyover should be available to make crossover of all sizes
required in BOQ and facilitate segregation and 90° crossing between data and power
wherever desired. Earth wire connector should be provided in all the boxes. Throwaway lid
should be provided free of cost to protect from water seepage during cementing/ screeding
process at site. Size - 250x250x55-70mm
Providing and erecting ,Fabricating the box type items made from M.S. Sheet with A.I.
supports, wings, doors, handles other hardware materials as per requirement design with
16.6 finishing by three tank powder coating processed inside and outside painted, erected as Kg. 179.00 2.00
directed including minor civil work.
Supplying and laying UPVC cable trunking system comprising unplasticised polyvinyl,
chloride rigid material with ignition free and flame proof confirming BS with necessary end
caps Internal and external bend, flat bends, coupler, tee etc..All necessary accessories and
16.7 measuring of following sizes Mtr. 1,309.00 60.00
(4)100 mm x 50 mm trunking with TWIN compartment With clip in divider
Item no. Item Description Unit Rate Total Qty. Amount
Supplying and laying UPVC cable trunking system comprising unplasticised polyvinyl,
chloride rigid material with ignition free and flame proof confirming BS with necessary end
caps Internal and external bend, flat bends, coupler, tee etc..All necessary accessories and
16.8 measuring of following sizes Mtr. 187.00 15.00
(3) 50 mm x 50 mm trunking
Providing & Erecting eight module pop up floor box/flushed with table surface Conform to
16.9 IEC 60670-1, IEC 60670-23 & IEC 60884-1 with required items as demanded by engineer in Each 1,529.00 1.00
charge with complete finishing .cat-III
Supply & installation of modular type accessories for U PVC snap-on adaptable
trunking/Pop up Box with required items erected with necessary connection. As desired by
16.10 Engineer In charge Each 204.00 1.00
i) 6 A SP 1 Way Switch cat-III
16.11 ii) 16A SP 1 Way Switch cat-III Each 351.00 2.00
16.12 iii) Bell Push 6 A SP 1 Way cat-III Each 288.00 2.00
16.13 iv) 6A universal socket shuttered cat-III Each 347.00 2.00
16.14 iv) 6/16 A universal socket shuttered cat-III Each 458.00 2.00
16.15 v) RJ-11 Telephone socket cat-III Each 244.00 2.00
16.16 vi) Cat-6 LAN Socket cat-III Each 561.00 2.00
Providing & erecting 16 gauge HGS conduit pipe (as per IS) painted black
surface/concealed of following size complete to be erected on/in wall or ceiling with erected
with necessary saddles, screws, bends, junction boxes etc. with following (Nominal Bore)
16.17 dia of pipes, in approved manner as directed Mtr. 107.00 15.00
Providing & erecting 16 gauge HGS conduit pipe (as per IS) painted black
surface/concealed of following size complete to be erected on/in wall or ceiling with erected
with necessary saddles, screws, bends, junction boxes etc. with following (Nominal Bore)
16.18 dia of pipes, in approved manner as directed Mtr. 138.00 15.00
Providing & erecting 16 gauge HGS conduit pipe (as per IS) painted black
surface/concealed of following size complete to be erected on/in wall or ceiling with erected
with necessary saddles, screws, bends, junction boxes etc. with following (Nominal Bore)
16.19 dia of pipes, in approved manner as directed Mtr. 226.00 15.00
Sub Total 16.....
Total Of Electrical Items Amount in Rs.
17 FIRE DETECTION & ALARM SYSTEM
Item no. Item Description Unit Rate Total Qty. Amount
Supply, Installation, Testing and Commissioning of Intelligent Addressable Fire Alarm
Control Panel. The Fire Alarm Control panel shall have inbuilt 4 loop and expandable upto
8 loops with each supporting 127 devices of any combination, and 127 analog sounder
bases. It shall have UL listed 10th edition, 4 programmable class B NAC circuits rated
Amps each, Class B or 2 Class A with internal synchronization. The user shall have a choice
of using the panel with 5.25 A (charges up to 60 Ah) or 10.25 A (charges up to 100 Ah)
power supply. The Panel shall have 3 voltage-free programmable inputs and
programmable relay outputs 30 V DC 1 Amp, 7 inch full-color resistive touch screen with
intuitive user interface, Up to 24 programmable soft “function keys”, Up to 64 user login
17.1 accounts, Hard-wired fire and trouble routing inputs and outputs, Modular and expandable Each 3,97,804.65 1.00
electronics, 400 sub address points per loop (800 per loop module), Option to “invert” inputs
and outputs. The panel shall support up to 5000 programmable Cause and Effects entries;
over 40,000 inputs and outputs, 10,000 events log @ 1 second resolultion, 2000 software
zones, 5000 software groups, 2 AUX 24V output each rated at 900 mA, Can be networked
with programmable functionality, Programming via USB port to PC or memory stick. The
Panel shall have dedicated RS232 serial port for optional printer, UL approved.
Supply, Installation, Testing & Commissioning of Network Vision Annunciator. The
Annunciator shall have Full color 7” (800 x 480 pixel) interface, Replicates information
17.2 displayed at the FACP, Automatic display brightness adjustment, Internal buzzer, Connects Each 1,22,171.42 1.00
via control panel network terminals, Low current, 24V DC powered, Configurable
functionality, Enable key-switch, Sheet steel enclosure, UL approved
Supply, Installation, Testing and Commissioning of Analog Multi-Criteria Sensor Features,
Low profile - only 2" high including base, variable sensitivity from 0.7 to 4% obs/Ft Simple
and reliable device addressing, Automatic compensation for sensor contamination , Built in
17.3 Fire test feature, Two built-in power/alarm LEDs, programmable non-polling LEDs, Non- Each 5,099.19 137.00
directional Smoke chamber, Vandal resistant security locking feature, Approved by UL and
Supply, Installation, Testing and Commissioning of Fixed Temperature/Rate of Rise
sensor, Low profile-only 2.00" high, including base, simple and reliable device addressing
17.4 method, Rate of rise temperature threshold = 15° F/Min, Adjustable threshold temperature = Each 4,483.94 108.00
135° - 190°, Approved by UL and FM
Supply, Installation, Testing and Commissioning of Multi-Criteria Sensor
(Smoke+Heat+CO) Features, Low profile - only 2" high, Simple and reliable device
addressing, Supports 16 operational modes, Automatic compensation for sensor
17.5 contamination , Built in Fire test feature, Two built-in power/alram LEDs, programmable non- Each 14,624.49 RO
polling LEDs, Non-directional Smoke chamber, Vandal resistant security locking feature,
years CO sensor life span, Approved by UL and FM
Supply, Installation, Testing and commissioning of sensor common mounting base,
17.6 includes stainless steel contacts, slim profile - only 8mm, quick connection via square Each 422.06 RO
cable clamps, facility for remote indicator, Approved by UL
Supply, Installation, Testing and commissioning of sensor common mounting base,
Features integral Short-Circuit isolator, slim profile, Approved by UL
Item no. Item Description Unit Rate Total Qty. Amount
17.8 Supply, Installation, Testing and Commissioning of Isolator module Each 4,482.71 25.00
Supply, Installation, testing and Commissioning of Dual Relay Module 2A @ 30 VDC/.5A @
120 VAC. The Module shall have two independently configurable Form C contacts per
address, Visible Bi-colored LED is software controlled and can be programmed to blink red
17.9 or green when polled. The LED can be latched on when activated, Yellow LED indicates a Each 8,474.45 19.00
short circuit condition, Programming is highly flexible providing 16 priority states plus zoning
capability, operates on Class A or Class b SLC loop, UL 864 Listed. Approved by UL and
Supply, Installation, Testing and Commissioning of Addressable Single Action Manual
Pull Station features including Addressable intergrated design, All metal construction,
17.10 Extremely easy to operate, Bi-colored status LED indicates standby and Alarm conditions, Each 8,264.04 19.00
Address is programmable in EEPROM, Enclosed switch with glass rod, Terminals accept up
to 14AWG wire, ADA compliant. Approved by UL and FM
Supply, Installation, Testing and Commissioning of low profile Horn/Strobe. The device
shall have Nominal voltage 24VDC. The device shall produce 100 dBA @ 10ft and has a
17.11 minimum flash rate of 1Hz regardless of input voltage. The device approved by UL and Each 10,109.79 29.00
Supply, Installation, Testing and Commissioning of Fast Response Contact Monitoring
Module. The Module shall have UL 864 9th Edition Listed, Single Input contact monitor, can
17.12 be programmed to monitor Normally Open (NO) or Normally Closed (NC) contacts, operates Each 5,362.52 19.00
on Class A or Class B SLC loop, Accepts up to 12 AWG wire. Approved by UL and FM
Supply, Installation, Testing and Commissioning of Class A Supervised Output Module.
The Module shall have Flexible application, Quick response to emergency conditions,
17.13 Contacts are rated 2.0 Amps@ 24VDC, Programming is highly flexible providing 16 prioriy Each 8,463.38 19.00
states plus zoning capability, Approved by UL and FM
Supply, Laying and Fixing of Red back box for mounting of detector, MCP and module
Supply, Laying and Fixing of 2 Core X 1.5 Sq.mm FRLS Multistrand PVC insulated
Copper armoured RED cable with all required accessories.
Sub Total 17.....
18 PUBLIC ADDRESS SYSTEM
SITC of Controller Public address and emergency sound system control unit
Control and routing of 4 simultaneous audio channels
One controller supports 12 zones, expandable up-to 492 zones with 24-zone routers
18.1 Four controllers can be networked using OMNEO interface module Nos 2,20,124.00 1.00
EN 54-16 and ISO 7240-16 system certification
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
Item no. Item Description Unit Rate Total Qty. Amount
SITC of Router Expansion of PAVIRO system by 24 zones
Total 4000 W speaker load, max 500W per zone
20 GPI, 24 GPO and 2 control relays
18.2 Up to 20 routers per controller Nos 1,88,860.00 1.00
EN 54-16 and ISO 7240-16 system certification
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of Power amplifier, 2x500W 2 ✕ 500 W class-D power amplifier (70/100 V output)
Low power consumption in standby mode
18.3 Excellent sound quality, high signal-to-noise ratio Nos 2,17,686.00 2.00
EN 54-16 and ISO 7240-16 system certification
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of Call station Call station with soft touch button for PAVIRO system
15 freely programmable buttons
Customization via built-in display and keys
18.4 Provision for installing emergency button and key switch Nos 78,156.00 1.00
EN 54-16 and ISO 7240-16 system certification
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer
SITC of Call station extension Call station extension keypad with 20 freely programmable
Soft-touch selection buttons
18.5 Up to 5 extension keypads can be connected to one call station Nos 46,891.00 1.00
EN 54-16 and ISO 7240-16 system certification
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of Ceiling loudspeaker 6W, ABS with clamps
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of ABS back box
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of Cabinet loudspeaker, 15W, black High-fidelity music and speech reproduction
Selectable 8 ohm, 70 V and 100 V inputs
Compact yet robust ABS enclosure
18.8 Supplied with adjustable mounting bracket Nos 9,288.00 RO
Complies with international installation and safety regulations
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of Horn loudspeaker 30W, circular, ABS
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
Supply, Laying and Fixing of 2 Core X 1.5 Sq.mm FRLS Multistrand PVC insulated Copper
armoured BLUE/BLACK cable with all required accessories.
Supply, Installation, Testing & Commissioning of 17U (600W X 600D)MM floor rack with
PDU, Horizontal Cable manager, self, mounting hardware and cooling fan with standard
18.11 accessories. UL Certified. Racks should be manufactured by ISO9001:2015, Nos 34,536.44 1.00
ISO14001:2004 & OHSAS 18001 : 2007, DIN41494 and Equivalent EIA/ISO/EN /CEA
Certified company and should have proper EHS Policy.
Sub Total 18.....
19 VOICE COMMUNICATION SYSTEM
Item no. Item Description Unit Rate Total Qty. Amount
Supply, Installation, Testing & Commissioning of IP-PBX System having the following
minimum specifications: Built-in Facilities: 4 Analog trunk (CO) port and 2 TDM Ports,
19.1 SIP Extensions,50 SIP IP Subscribers, 8 SIP Trunks, minimum 4 Voice mai Channel, Nos 38,432.21 1.00
Optional Interfaces: GSM Module, Power Supply: External power Adaptor - 24V DC, 2.5A.
Supply, Installation, Testing and Commissioning of SIP-based IP Telephone with PoE
support, supporting standard SIP protocol, dual Ethernet ports, display (minimum 124 ×
19.2 pixels), minimum 3 programmable feature keys, minimum 4 context-sensitive keys, Nos 6,803.43 37.00
dedicated volume control keys, and power support via PoE and 5V DC, 0.6A external power
Sub Total 19.....
Total Of ELV Items Amount in Rs.
20 MAINTENANCE & OPERATION FOR ELECTRICAL & ELV WORK
Provide annual maintenance service (including supply of material) and operation for 3 years
20.1 after handing over of work for electrical and ELV works as per schedule including necessary Year
materials to be given under warantee free of cost, etc.
20.2 1st Year ( From the date of Completion of DLP ) Year 8,41,564.57 1.00
20.3 2nd Year ( From the date of Completion of DLP ) Year 8,41,564.57 1.00
20.4 3rd Year ( From the date of Completion of DLP ) Year 8,41,564.57 1.00
20.5 4th Year ( From the date of Completion of DLP ) Year 8,41,564.57 1.00
Sub Total 20.....
(a) General Features & Special Features of the all lift items shall be taken as below.
(b) for Handicap Lifts, Minimum 10 Passengers Lift Capacity shall be considered.same is to
be informed to architect /civil authority to keep necessary size of lift well.
(c) The lifts of 15/ 16 and above passenger capacity shall be taken for Hospital Lifts; Where
in Description “ Stretcher Lifts” shall be mentioned.
(d) The Rates of the following items are for the lift of Machine room less. For Machine room
Lifts, rate for Rs. 1,50,000/- shall be deducted in Total Cost for the Lifts from 4 to
Passenger Lift. Rs. 2,00,000/- shall be deducted in Total Cost for the Lifts 15 and above
(e) Add Rs.capacity
80,000/-asforextra cost.
the DUPLEX control for the lifts up to 10 floors and add Rs. 10,000/-
for additional each floor above 10 floors.
(A) GENERAL DESCRIPTION OF LIFTS.
[1] GEAR LESS LIFT DRIVE (MRL) comprising of High Starting torque Lift 3 phase 440 V A.
C. Permanent Magnet Synchronous motor of proper rating with high efficiency shall be
used.[2] Micro processor based / PLC, ACVVVF, vector control drive with encoder feedback
closed loop system shall be used for lift car and door operation which shall be full collective
selective operation hall call demand response, UP/DOWN hall stops, Main, Up/ Down
[3] Car with M S platform with bracings of adequate size and to sustain the impact load
cabin + passenger with safety factor of fire for steel and side panels of Stainless steel of
sheet of grade 304 duty. Car ceiling will be S.S. finishes with aesthetic appearance with LED
ceiling lights. Car flooring shall be of s/s 304 chaker plate design sugeested of engineer in
charge. of engineer in charge. Car doors shall be of stainless steel grade 304, hairline finish
with centre opening / telescopic automatic doors. Car panel will also be S.S. 304 finished
with emergency stop device, mechanical door safety device, facility of auto/ attended mode.
Item no. Item Description Unit Rate Total Qty. Amount
[4] All landing doors must be fire rated for 2 hour shall be fully automatic centre opening/
telescopic opening made of hairline finish steel grade of 304 with key holes and infrared
curtains with Unlocking facility from outside
[5] Appropriate battery operated emergency light in the car along with alarm switch shall be
provided. Also, Emergency Light & Fan should start immediately without any Time Delay as
soon as power fails.
[6] Digital scrolling indicator system for up-down arrow along with floor position indicator
shall be provided inside the car and at all floors.
[7] Full height infra red curtain with multiple cross / crossing light beams shall be provided.
[8] Automatic Rescue Device (ARD) shall be provided accordingly of passenger capacity
with Manual Rescue Operation ( Manual Cranking Facility).
[9] Audio visual indication in the lift car showing over loading shall be provided such that
doors kept open till excess load is removed.
[10] Spring buffers/PU Buffers shall be provided.
[11] Car fan as per passenger capacity with automatic sleep timer shall be provided.
[12] Voice annunciator with suitable music shall be provided in lift car.
[13] Self diagnostics system for operational and safety parameters shall be provided in
[14] Mechanical over speed governor with governor calibration as per actual site parameters
and submission of calibration certificate submission, door key holes in the floor doors,
fireman switch shall be provided.
[15] Lift machine hoisting arrangement in the lift machine room and monkey ladder for lift pit
should be provided by the lift agency, along with the other steel structure works, foundations
[17] machine wiring
Permanent etc… with necessary safety devices like RCCB in all circuit, Over Voltage
Under Voltage protection and THD eliminator in circuit for lift machine room and lift well with
proper numbers of light points, with fixtures, exhaust fan and plug points shall be provided
by the agency. Only 3 phase Power Supply shall be made available by department in lift
machine room. Necessary Earthing as per Lift Act/Rules shall be arranged by Lift Agency.
[18] Any civil/ electrical works for additional and alteration in lift shaft and machine room
related to erection of lift shall be made by lift agency without any extra cost. (granite/marble
fixing around all landing door openings are not in lift agency’s scope.)
[19] Agency has to provide all working drawings and documents and liaison services for
obtaining all necessary permission from lift inspector and other authorities.
As pertransparent licence/display
statutory requirement A4 size
of Govt. holder inliftlift&car
Of Gujarat escalator act 2000, lift agency
1. Car top safety barricade
2. Push & talk communication system.
3. Fireman's switch operation at Ground Floor.
4.carrying out third party lift inspection during/after lift erection and provide report by third
party authorized by concern licensing authority 5.agency has to provide third party
insurance upto completion of free maintenance period and submit the document for the
Item no. Item Description Unit Rate Total Qty. Amount
[21] Car Panel Operating Buttons with floor position indicator/buttons must be of Auto Glow
type clearly visible when view from inside cabin.
[22] For Physically Handicapped person Full Length Handrails of hairline finish steel grade
of 304 should be provided at appropriate height on the Rear & Side Wall Panels in Lift Car.
[23] With Necessary KVA rating voltage controlled Stabilizer suitable for your controller,
drive and all equipments of lift.
[24] Necessary rating of DP Elcb and FP Elcb required for lift is in scope of work which
(B) SPECIAL FEATURES DESCRIPTION OF LIFTS for PREMIUM category
1. Advanced control system dual 64 bit embedded microprocessor with CANBUS Serial
Communication mode including Regenerative power efficient operation,on site programming
facility, Anti nuisance, Pte-opening, BMS/RMS with necessary online real time monitoring
system having necessary connectivity for remote monitoring & other suitable supporting
hardware & software devices to fulfil the purpose.
2. Floor Indication LCD Display with call registration & brail mark with arrival gong and hall
lantern & TFT Screen in the car with MP3 Voice Announcer.
3. CAR Panel should be Scratch resistive SS Moonrock finish / Hair Line / Honeycomb for
car and all Doors, All landing doors must have fire rating up to 2 hours and car door must
have multi-level crisscross beam door protection.
4. To & fro communication system & wiring (i.e. car , control room & guard room ) and Each
elevator are equipped with remote monitoring system.agency has to provide mobile app
and user id and password for monitoring
21.1 DESCRIPTION OF LIFT :
Supplying, Erecting, Testing & Commissioning the passenger / stretcher lift having following
8 / 10 Passengers, Ground plus 11 upper floors with Rated Speed of 2.0 / 2.5 m/sec.,
(B) With General PLUS ADDITIONAL SPECIAL FEATURES attached herewith. Prem. Cat.
8 / 10 Passengers,. Ground plus 4 upper floor with Rated Speed of 1.0 m/sec.,
21.1.2 (C) With General PLUS ADDITIONAL SPECIAL FEATURES attached herewith. Prem. Cat. Each 16,59,857.00 2.00
21.2 Additional facilities for lift
Supplying & erecting approved make Lift Announcing solid state system in the Passenger/
Stretcher lifts having AC2/ACVV/ACVF drives & automatic doors only. The system
comprising following features & facilities.
(i) Announcing floor message, message to close period.(ii) Announcing ‘Emergency
21.2.1 Message’ when lift is stuck between floors due to power failure or any other reason. Each 16,950.00 4.00
(iii) Instrumental Music between floor announcing.(iv) Announcement in English / Hindi &
Gujarati Languages..
(v) Flexible to accommodate special per-programmed message such as name of the
Providing/office.(vi)Volume adjustment
& erecting approved control non-start feature & overload warning Indicator
system in the lift with making use of sound isolated floating platform & micro switches on SI
frame to get sensation of live load inside lift cage at any given moment, with provides new
21.2.2 fixtures of overload warning inside lift cage with new relay in the existing control panel to Each 32,205.00 4.00
activate ‘Overload Non-Start Function with carrying out additional wiring including laying of
new travelling cable, include minor civil work & without changing the existing capacity speed
stops, travel & operation of the desired lift
Item no. Item Description Unit Rate Total Qty. Amount
Sub Total 21.....
22 COMPREHENSIVE MAINTENANCE FOR LIFT WORK
Provide Comprehensive Maintenance (After Defect Liability Period) Of All LIFTS including
22.1 all Electromechnical Items / Spare parts, Material and Labour with all respect During DLP-
22.2 1st Year ( From the date of Completion of DLP ) Year 2,97,356.92 1.00
22.3 2nd Year ( From the date of Completion of DLP ) Year 2,97,356.92 1.00
22.4 3rd Year ( From the date of Completion of DLP ) Year 3,39,836.48 1.00
22.5 4th Year ( From the date of Completion of DLP ) Year 3,82,316.04 1.00
Sub Total 22.....
Supply, Installation, Testing and Commissioning of 2MP Bullet Camera having 3.6mm fix
lens, 1/2.8” image sensor, 0Lux with IR LED on, IR Distance up to 50m, H.265/H.264/M-
23.1 JPEG Video Compression, PoE Support, SD Card slot, support triple Stream or higher, 1/1 Nos 20,933.27 34.00
Audio I/O, 1/1 Alarm I/O, Certification: BIS, CE, FCC, IK10, IP67, ONVIF, UL listed, STQC
Supply, Installation, Testing and Commissioning of 2MP Dome Camera 2.8mm fix lens,
1/2.8” image sensor, 0Lux with IR LED on, IR Distance up to 50m, H.265/H.264/M-JPEG
23.2 Video Compression, PoE Support, SD Card slot, support triple stream or higher, 1/1 Audio Nos 20,933.27 61.00
I/O, 1/1 Alarm I/O, Certification: BIS, CE, FCC, IK10, IP67, ONVIF, UL listed, STQC
Supply, Installation, Testing and Commissioning of 64 Channel NVR with 4K Support and
HDD Slots (support up to 18TB capacity per slot), having 4K HDMI, 1/1 Audio I/O and 2/1
Alarm I/O, 12MP, 8MP, 5MP, 4MP, 3MP, 2MP, 720p, D1 and CIF Recording Resolution, 4x
4K/ 10x 3MP/16x 1080p Local Decoding, Save Storage Space with Adaptive Recording and
23.3 Camera-wise Recording Retention, SMS & Email Notification, Video Pop-up, Alarms and Nos 1,17,338.02 2.00
Calling from Mobile Application, Throughput - 512Mbps Uplink, 512Mbps Downlink, ONVIF
and Major Camera Brands Support, Cascading: Create Mutiple NVR Clusters to Monitor and
Control Multiple NVRs Centrally, NDAA Compliant.
Supply, Installation, Testing and Commissioning of 10 TB Surveillance Hard Disk for
days recording at 25 fps on 2 MP resolution
Supply, Installation, Testing and Commissioning of CCTV management work station
Processor: i7-12700-12th Gen OS: Windows 11 Pro DEFAULT STORAGE: 512 GB SSD,
23.5 RAM: 32 GB DDR5, (16 GB DDR5 - 2 nos), NVIDIA T400 4 GB Quadro graphic card, Nos 3,19,051.42 1.00
Additional Storage: 512GB HDD, KEYBOARD - 1 nos, MOUSE - 1 nos
Supply, Installation, Testing & Commissioning of 65-inch Professional Grade Display
suitable for 24/7 usage, with minimum 400 nits brightness, 50,000 hours panel life, HD
23.6 resolution (1920x1080), 20W built-in speakers, Connectivity: 2 x HDMI 2.0 port, 2 x USB Nos 1,42,123.98 2.00
port, 1 x 1G Ethernet ports, 10 mtr HDMI cable.
Sub Total 23.....
24 NETWORKING SYSTEM
Item no. Item Description Unit Rate Total Qty. Amount
Supply, Installation, Testing & Commissioning of 15U (550W X 600D)MM Wall mount closed
rack with PDU, Horizontal Cable manager, self, mounting hardware and cooling fan with
24.1 standard accessories. UL Certified. Racks should be manufactured by ISO9001:2015, Nos 20,615.80 9.00
ISO14001:2004 & OHSAS 18001 : 2007, DIN41494 and Equivalent EIA/ISO/EN /CEA
Certified company and should have proper EHS Policy.
Supply, Installation, Testing & Commissioning of 27U (600W X 600D)MM Wall mount closed
rack with PDU, Horizontal Cable manager, self, mounting hardware and cooling fan with
24.2 standard accessories. UL Certified. Racks should be manufactured by ISO9001:2015, Nos 42,613.45 RO
ISO14001:2004 & OHSAS 18001 : 2007, DIN41494 and Equivalent EIA/ISO/EN /CEA
Certified company and should have proper EHS Policy.
Supply, Installation, Testing & Commissioning of 42U (800W X 1000D)MM floor rack with
PDU, Horizontal Cable manager, self, mounting hardware and cooling fan with standard
24.3 accessories. UL Certified. Racks should be manufactured by ISO9001:2015, Nos 87,583.30 1.00
ISO14001:2004 & OHSAS 18001 : 2007, DIN41494 and Equivalent EIA/ISO/EN /CEA
Certified company and should have proper EHS Policy.
SITC of O. F.Cable 06F Outdoor - Armoured Unitube SM - HDPE Sheath [Approved by
Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of LIU 12 PORT Rack Mount - Loaded (LC) SM
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of PATCH CORD LC-LC SM DUPLEX LENGTH- 3m
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of CAT6 UTP 23AWG Solid: Per Meter
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of Patch Panel Cat 6 UTP Keystone Type- 24 Port-Fully Loaded
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of Jack Cat 6 Keystone UTP
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of Face Plate - Single (Keystone Jack,square)
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of Face Plate - Dual (Keystone Jack,square)
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of CAT6 UTP 24AWG PATCH CORD:1M,Plug 30U' Snag less
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
SITC of CAT6 UTP 24AWG PATCH CORD:2M,Plug 30U' Snag less
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
24.14 SITC of RJ45 Connector Nos 36.92 100.00
SITC of 24 x 10/100/1000BASE-T PoE ports
4 x Gigabit RJ45/SFP Combo ports
Advanced L2 switching and security features
24.15 L2+ Static Routing Nos 31,680.00 12.00
Optional “standard mode” or “surveillance mode” management user interface
193 W PoE budget
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
Item no. Item Description Unit Rate Total Qty. Amount
SITC of 24 x 10/100/1000BASE-T ports
4 x Gigabit RJ45/SFP Combo ports
Advanced L2 switching and security features
24.16 L2+ Static Routing Nos 15,247.00 1.00
Optional “standard mode” or “surveillance mode” management user interface
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
Supply, Installation, Testing and Commissioning of 4X4 Dual Band PoE Multi-Gig Wi-Fi
Access Point, Management: stand alone or cloud controller, security :WPA3, wall\ceiling
24.17 mount (Kit included ), Total users supported: 250, Concurrent Users:75, Including 3 year Nos 50,187.17 3.00
Cloud controller based license
SITC of Maximum distance of up to 10 km
Single-mode fiber
24.18 1000BASE-LX (IEEE 802.3z standard) Nos 4,754.00 20.00
Duplex LC connector
MSA, RoHS-compliant [Approved by Competent Authority i.e. not Below the rank of
Executive Engineer ]
Supply, Laying and Fixing of 25 mm diameter MMS PVC conduit with all required
24.20 Supply, laying and fixing of HDPE pipe 25mm Mtr. 123.05 20.00
24.21 Supply, Laying and Fixing of Flexible Pipe White 32 MM Mtr. 76.29 300.00
24.22 Supply, Laying and Fixing of Flexible Pipe White 50 MM Mtr. 95.98 100.00
24.23 Supply, Installation, testing and commissioning of 100 x 50 mm trunking Mtr. 705.08 25.00
Supply, installation, testing and commissioning of 4KE (WUXGA) Resolution, 5200 lumens
Laser projector,16:10 Aspect ratio, Over 5,000,000:1 Contrast ratio, 127 - 1270 cm (50 -
24.24 500") diagonal image size,Interfaces : HDMI in Nos 2,71,657.49 RO
x2, HDMI out, HDBaseT, RS-232C, USB Type A (2A), USB Type B, with ceiling mount kit
(2feet + 2feet) or as per site requirement technical specification etc. as required.
Supply, installation, testing and commissioning of 135 inch Fiber Glass MW Tubular
24.25 Motorized Screen with RF remote, Aspect Ratio-16:10 as per the technical specifications Nos 34,832.99 RO
etc. as required.
Sub Total 24.....
Total Of CCTV & Networking System Items Amount in Rs.
25 COMPREHENSIVE MAINTENANCE FOR CCTV & NETWORKING SYSTEM
25.1 Provide Comprehensive Maintenance (including supply of material)
and operation for 4 years after handing over of work for CCTV &
Networking System works as per schedule including necessary Year
materials to be given under warantee free of cost, etc.
25.2 1st Year ( From the date of Completion of DLP ) Year 1,47,064.63 1.00
Item no. Item Description Unit Rate Total Qty. Amount
25.3 2nd Year ( From the date of Completion of DLP ) Year 1,47,064.63 1.00
25.4 3rd Year ( From the date of Completion of DLP ) Year 1,47,064.63 1.00
25.5 4th Year ( From the date of Completion of DLP ) Year 1,47,064.63 1.00
Sub Total 25.....
AHMEDABAD MUNICIPAL CORPORATION
Construction of Fire Station and Staff Quarters at Kathwada T.P 117 F.P. 364 at Nikol Ward, East
Zone, Ahmedabad city under Building Project Department.
SUBESTIMATE - 05 : PHE WORK
ITEM DESCRIPTION AMOUNT
1 SANITARY FIXTURES AND FITTINGS
INTERNAL DRAINAGE AND RAIN WATER WORKS (SOIL, WASTE, VENT AND RAIN WATER PIPING &
3 INTERNAL WATER SUPPLY NETWORK
4 EXTERNAL WATER SUPPLY NETWORK
5 EXTERNAL SEWAGE NETWORK
6 EXTERNAL STORM NETWORK
7 PUMP AND EQUIPMENT WORKS
AHMEDABAD MUNICIPAL CORPORATION
Construction of Fire Station and Staff Quarters at Kathwada T.P 117 F.P. 364 at Nikol Ward, East Zone, Ahmedabad city under
SUBESTIMATE - 05 : PHE WORK
Item no. Item Description Unit Rate Total Qty. Amount
SANITARY FIXTURES AND FITTINGS
SPECIAL NEED FOR DISABLED TOILET
Providing and Fixing EWC wall hung, Wash basin, Grab bar, Hinged rail & special
faucet with spachula including seat cover, and concealed cistern body with control plate,
fittings, nuts, bolts and gasket etc complete for disabled toilet of approved make and
conforming to IS Standards. Wash basin with one pair mounting brackets, Waste
coupling 32 mm size full thread with 80 mm heightJaquar make with 7 years warranty:
Chrome plated, Bottle trap Jaquar make with 7 years warranty: Chrome plated etc.,
EWC S Trap & Cistern complete with fittings & seat cover, one no. hinged rail 750 mm
& Two nos of grab rails 600 mm ,etc. complete as per directed by the Engineer's
Representative.
1.01 W.C Wall Hung : Jaquar, Model No. : DIS-WHT- 93955P180UF Set. 1 55,675.00
Concealed Cistern : Jaquar, Model No. : JCS-WHT-2400P
Flush Plate : Jaquar, Model No. : JCP-CHR-152415
Wash Basin : Wall Hung Basin With Fixing Accessories, Size : 650X565X155 Mm
Cat. No. ALD-CHR-573 Hand Shower (Health Faucet) With 8Mm Dia 1 Meter Long
Flexiăle Tuăe And Wall Hook
Cat. No. WAC-SAP- BR0600CSN Wall mounted Grab Bar 680 mm Long
Cat. No.WAC-SAP- BG0800CSN Grab Bar Vertical Swing
Providing and fixing wash down wall mounting EWC-P of approved shade, conforming to
Pattern 2 of IS: 2556 (Part -II), with SWR Self it Soil PVC pipe and plug bend as per
specifications; glazed vitreous / Coloured European Water Closet with Metropole flush
valve, connecting PVC 110mm dia soil pipe with PVC coupling, nuts, mounting cistern
on WC., Ragbolt, Gasket Fitiiing and solid verity heavy duty plastic seat cover as per IS-
2548, of approved make; hole in walls/slab/beam and making good etc. complete as per
directed by the Engineer's Representative.
EWC-P with PP Soft close Seat cover, Cistern with cistern fittings:
W.C Wall Hung : Jaquar, Model No. : ARS-WHT- 39953BIUFSM
Concealed Cistern : Jaquar, Model No. : JCS-WHT-2400FS
Flush Plate : Jaquar, Model No. : JCP-CHR-292415
Item no. Item Description Unit Rate Total Qty. Amount
Providing and fixing in position 15 mm C.P. brass bib cock of best quality including
cutting and making good the wall where required etc. complete as per directed by the
Engineer's Representative.
Bib Cock : Jaquar, Model no.
Providing and fixing 15mm C.P. brass angle valve with wall flange complete, including
cutting and making good the wall where required etc. complete as per directed by the
Engineer's Representative.
Angle Valve :Jaquar, Model No. OPP-CHR-15053PM
Providing and fixing of Hand Shower (Health Faucet), with 8mm Dia,1Rmt Long pvc
Tube and Wall Hook accessories to .complete the item etc. complete as per directed by
the Engineer's Representative.
Health Faucet :Jaquar, Model no.ALD-CHR-565
Providing and fixing White glazed vitreous Oval Wash Basin Under-Counter, size
560x430x195 mm., with supporting M.S. or C.I. Brackets, necessary pipe connection up
to the outside face of the wall, having Telephonic Black / Colour Granite of 180 mm
thick fixed on Black Kadappa Framework, Waste coupling 32 mm size full thread with
mm height Chrome plated, Bottle trap Chrome plated , Pressmatic Pillar Cock including
necessary fittings with wall Flange etc. complete in all respects including cutting and
making good the walls etc. complete as per directed by the Engineer's Representative.
Wash basin : Jaquar, Model No. : FLS-WHT-5701
Waste coupling : Jaquar, Model No. : ALD-CHR-705
Bottle trap : Jaquar, Model No. : ALD-CHR- 769L300X190
Providing and fixing Pressmatic Pillar Cock of best quality necessary fittings with Flange
etc. complete in all respects including cutting and making good the walls etc. complete
as per directed by the Engineer's Representative.
Pressmatic Pillar Cock :FLP-CHR-5031PM
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
AMCFS_Vol_1_Technical_Bid_General_Terms_and_Conditions_KATHWADA.pdf
AMCFS_Vol_2_DTS_and_Drawings_Kathwada-1-250.pdf
AMCFS_Vol_2_DTS_and_Drawings_Kathwada-251-500.pdf
AMCFS_Vol_2_DTS_and_Drawings_Kathwada-501-676.pdf
AMCFS_Vol_3_Financial_Bid_Kathwada.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .