Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.6 LAccepted-AOC B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | L1 | Accepted-AOC BEING THE LOWEST BIDDER | |
| 2 | L2₹32.9 L+₹3.6 L (12.3%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 3 | L3₹33.6 L+₹4.3 L (14.8%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
14 Feb 2024, 6:00 pmClosed
GE (AF) Chiloda
GE (AF) Chiloda, Lekawada Patia, PO CRPF Campus, Gandhinagar (Gujarat)-382042
COMPREHENSIVE DAY TO DAY REPAIR AND MAINTENANCE OF INTERNAL ELECTRIFICATION SERVICES AND REPAIR AND MAINT OF WATER SUPPLY AND ELECTRIC SUPPLY INSTALLATIONS AND ALLIED WORKS AT SECTOR-25 AND 27 OF GANDHINAGAR
2023_MES_632321_2
8983/23-24/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Gandhinagar
As per NIT
7 documents required · 7 mandatory
₹500
GE (AF) Chiloda
₹60,000
Yes
28 Mar 2024
24 Jan 2024
16 Feb 2024
24 Jan 2024
14 Feb 2024
1 Feb 2024
24 Jan 2024 - 31 Jan 2024
Amount
Taking down carefully copper/ aluminum point wiring of any size and description (Light, fan, socket, power and Bell) including fixture and fittings such as switches, sockets, ceiling roses, lamp, holder , regulators, sockets light fittings etc , removing material for taking credit and making good disturbed surface of walls, floors, etc. complete all as specified and directed.
Material and labour for point wiring for one light point or one fan point or one bell point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core,FRLS PVC insulated & unsheathed cable, 1100 volts grade drawn through existing concealed PVC conduit and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, FRLS PVC insulated & unsheathed cable as in earth wire connected to common earth dolly factory made GI sheet sunken box complete all as specified and directed.
All as per Serial item No. 2 here-in-before but point wiring for 3/ 5 pin switch socket outlet combination, 5 amps on same board.
All as per Serial item No. 2 here-in-before but point wiring for 3/ 5 pin switch socket outlet combination, 5 amps on independent board.
All as per Serial item No. 2 here-in-before but point wiring for one 6 pin switch socket outlet combination, 5/15 amps (independent) with using 2.5 sq.mm (nominal area) copper PVC insulated unsheathed stranded copper conductor as continuous earth wire on independent board for one socket outlet 3 pin 15 amps complete all as specified and directed.
Supply & Fixing Modular switch 1 way 10A 1 module complete all as specified and directed.
Supply & Fixing Modular switch 1 way 16A 1 module complete all as specified and directed.
Supply & Fixing Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed.
Supply & Fixing Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed.
Supply & Fixing Fan step regulator, 120W - 2 module complete all as specified and directed.
Supply & Fixing in repair white cover plate with frame, 2 module complete all as specified and directed.
Supply & Fixing in repair white cover plate with frame, 3 module complete all as specified and directed.
Supply & Fixing in repair white cover plate with frame, 6 module complete all as specified and directed.
Supply & Fixing in repair white cover plate with frame, 8 module complete all as specified and directed.
Supply & Fixing in repair white cover plate with frame,12 module complete all as specified and directed.
Supply & Fixing in repair Bell Multi Music type complete all as specified and directed.
S & F in repair switch piano type 230 volts, 5 Amps, single pole complete all as specified and directed.
S & F in repair switch piano type 230 volts, 15 Amps, single pole complete all as specified and directed.
S & F in repair Socket out let 2 in 1, 3 pin, 5 Amps flush type 230 volts complete all as specified and directed.
S & F in repair Switch Socket out let combination 2 in 1, 3 pin, 5 Amps flush type 230 volts complete all as specified and directed.
S & F in repair Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type complete all as specified and directed.
S & F in repair for ceiling rose surface bakelite, three terminals complete all as specified and directed.
S & F in repair fan regulator step type suitable for ceiling fans, prewired 230 volts AC 50Hz supply 60/100Watt complete all as specified & directed. Note for Item No 16 to 22: Unwanted delay in attending/ rectification of day to day complaint if noticed the recovery shall be made Rs 500/- per day from contractor bill till complete the job.
M&L for point wiring for one light or one fan or one bell point controlled by one switch with using 1.5 Sqmm single core FRLS PVC insulated unsheathed multi stranded copper conductor cable 1100V grade drawn through with incl PVC casing in capping /conduit (size of as required at site but not less than 20mm) with accessories like bends tees, junction boxes and terminal boxes for mounting fittings etc. fixed on recessed in wall or ceiling etc including 1.5 Sqmm single core FRLS PVC insulated but unsheathed multistrandard copper conductor cable 1100V grade as earth continuity wire connected to common earth dolly with incl PVC board size as required at site complete all as specified and directed.
All as per Serial item No. 24 here-in-before but point wiring for 3/ 5 pin switch socket outlet combination, 5 amps on same board.
All as per Serial item No. 24 here-in-before but point wiring for 3/ 5 pin switch socket outlet combination, 5 amps on independent board.
All as per Serial item No. 24 here-in-before but point wiring for one 6 pin switch socket outlet combination, 5/15 amps (independent) with using 2.5 sq.mm (nominal area) copper PVC insulated unsheathed stranded copper conductor as continuous earth wire on independent board for one socket outlet 3 pin 15 amps complete all as specified and directed.
Supply and fixing switch piano flush type, 5 amps, single pole, one way, 230 volts AC complete all as specified and directed.
Supply and fixing for Bell push flush type, 5 Amps, single pole, 230 volts AC complete all as specified and directed.
S & F for call bell AC, 230 volts, single pole complete all as specified and directed.
S & F for socket outlet, three pin, 5 amps, flush type, 230 volts AC complete all as specified and directed.
S & F for switch socket outlet combination, three pin, 5 amps, flush type, 230 volts AC complete all as specified and directed.
S & F for switch socket outlet combination, multipurpose, 3 pin, 15 amps and 3 pin 5 amps controlled by one switch, flush type, 230 volts AC complete all as specified and directed.
S & F fan regulator step type suitable for ceiling fans, prewired 230 volts AC 50Hz supply 60/100Watt complete all as specified & directed
M & L for in repair of sub main wiring using two single core FRLS PVC insulated, unsheathed stranded copper conductor cable of size 4 Sq.mm of 1100 Volts voltage rating drawn through and including PVC casing caping of size not less than 25mm with standard accessories, along-with one run of FRLS PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4.0 Sq.mm as earth continuity conductor complete all as specified and directed. Note : Two run of single core FRLS PVC cable with one run of earth conductor and conduit shall be measured as one unit.
All as per Serial item No. 35 here-in-before but sub main wiring with using two single core 6.0 sqmm FRLS PVC insulated stranded copper conductor cable
Supply & Fixing in repair industrial type sheet metal enclosures with a two pin and earth plug and socket, 250 volts with including 20 Amp SP MCB complete all as specified and directed.
S & F in repair for PVC insulated aluminium stranded conductor of size 10.0 sq.mm twin core flat or circular cable 1100 volt grade, heavy duty cable, served with inner sheathed cable complete all as specified and directed.
Supply, fixing, connecting and testing sheet metal enclosures double door type for using MCBs suitable for single pole and neutral, 16 way with having copper bus bars suitable for 200 amps rating including taking down old unserviceable one complete all as specified and directed.
All as per item No 39 above but 12 way
All as per item No 39 above but 8 way
All as per item No 39 above but 4 way
Supply, fixing, connecting and testing sheet metal enclosures double door type for using MCBs suitable for single pole and neutral, 4 way TPN with having copper bus bars suitable for 200 amps rating including taking down old unserviceable one complete all as specified and directed.
S & F in repair MCCB 4 Pole, 415 V, fixed type, 100 Amps with breaking capacity 16 KA with including IP 65 sheet metal encloser complete all as specified and directed.
S & F in repair MCB Triple pole & neutral (TPN), 32 to 63 Amps, 240 volts, 10KA, ‘C’ series, with proper size lugs and connections complete all as specified and directed.
S & F in repair MCB single pole & neutral (SP&N), 16 to 32 Amps, 240 volts, 10KA, ‘C’ series, with proper size lugs and connections complete all as specified and directed.
S & F in repair MCB single pole (SP) 6 to 32 Amps, 240 volts, 10KA, ‘B’ series, with proper size lugs and connections complete all as specified and directed.
S & F in repair Surface and wall mounted high LED light fitting 20 watt, efficiency 100 Lm/watt, 230 volt, decorative polycarbonate housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver CRI >80, Beam Angle 120° complete with all accessories internally pre wired and including connection up with twin core flexible copper conductior cable complete all as specified and directed.
S & F in repair LED light fitting 10 watt, efficiency 100 Lm/watt, 230 volt, 2 feet, decorative polycarbonate. Extruded Thermoplastic body with PC Diffuser in square shape, CRI >80, Beam Angle 120° including connecting up with twin core flexible copper conductor cable of suitable size complete all as specified and directed.
S & F in repair round or Square shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S & F in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S & F in repair LED light fitting 1x9W/1X10W bulkhead luminaires including LED light holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S & F in repair for outdoor type IP66, Energy saving LED street light fitting 30 Watt 230 V AC with PDC Aluminium body & Secondary optical lens for superior light distribution. Efficacy >110 Lm/W. with high pressure die cast aluminum hosing and heat resistant LED street light fitting with driver, complete all as specified and directed.
S & F in repair for outdoor type IP66, Energy saving LED street light fitting 90 Watt 230 V AC with PDC Aluminium body & Secondary optical lens for superior light distribution. Efficacy >110 Lm/W. with high pressure die cast aluminum hosing and heat resistant LED street light fitting with driver, complete all as specified and directed.
S & F in repair for Decorative, wall mounting, brushed nickel finish fixture with dual Opal Glass diffuser suitable for LED lamp B22 Base complete all as specified and directed.
S&F in repair intrigal decorative LED bollard with opal acrylic 9 watt LED 3000K with IP 65 protection as per existing sample complete all as specified and directed.
S& F in repair decorative coloured flood light , suitable for focasing of tree / buildings of capacity 100 watt, 240 volt, 50 HZ complete all as specified and directed.
S&F in repair Post top lanterned 20 watt suitable for 180 volt to 280 volt complete all as specified and directed.
S&F in repair LED strip suitable for decorative 30 meter LED rope light, water proof, RWG colour with adaptor, suitable for 180 volt to 280 volt complete all as specified and directed.
Supply & Fixing in repair Ultra bright polycarbonate LED retrofit tube light rod 18 watt with very high efficiency complete all as specified and directed.
S & F in repair for High light intensity empowered color changing & monochromatic LED under water fountain light with polarized light design & intelligent logarithmic control technology as per existing sample complete all as specified and directed.
S&F in repair water proof led power supply controler (SMPS) of capacity 500 watt, input 230 volt and out voltage DC 12 V, +- 5%, suitable for control fountain LED lights as per sample complete all as specified and directed.
Supply & fixing in repair LED bulb retrofit type 7 watt, efficacy 100 Lm/W suitable for 180 volt to 280 volt E22 & E27 type complete all as specified and directed.
Supply & fixing in repair LED bulb retrofit type 9/10 watt, efficiency 100 Lm/W suitable for 180 volt to 280 volt complete all as specified and directed.
Supply & fixing in repair LED bulb retrofit type 15 watt, efficacy 100 Lm/W suitable for 180 volt to 280 volt complete all as specified and directed.
Supply & fixing in repair LED bulb retrofit type 0.5 watt, Red/ Green colour suitable for 180 volt to 280 volt complete all as specified and directed.
Supply & fixing in repair 9/22 watt LED driver suitable for 180 to 275 volt LED light fitting complete all as specified and directed.
Supply & fixing in repair 15/18 watt LED driver suitable for 180 to 275 volt LED light fitting complete all as specified and directed.
Supply & fixing in repair 36/42 watt LED driver suitable for 180 to 275 volt LED light fitting complete all as specified and directed.
Supply & fixing in repair of Decorative post top lantern doom made up of high grade unbreakable polycarbonate material suitable for retrofit LED lamp B22 base as per existing sample complete all as specified and directed.
S & F in repair of multi stranded copper conductor cable of size 1.0 sq.mm, 3 core including taking down of existing unserviceable one complete all as specified and directed.
S & F in repair Rigid non-metallic PVC conduit/ PVC casing caping inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed.
S & F in repair light fitting 1x30 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as per shown in electrical plate No. 5 of MES Schedule Part-I with connected to earth test point main switch board with including necessary earth work and Pre- cast RCC earth pit with cover and including dismantling/taking out of old unserviceable earthing of any position complete all as specified and directed.
All as per Serial item No. 74 here-in-before but using galvanised iron strip 32×6mm as earthing lead complete all as specified and directed.
M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 2 mm dia galvanised iron or steel wire complete all as specified and directed.
All as per Serial item No 76 here-in-before but using 20x3mm copper strip.
S & F in repair of GI pipe 40 mm dia light grade for earth strip protection complete all as specified and directed.
M & L for replacement of Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hex. head screw complete all as specified and directed.
M & L for colour coding of earthing pit cover with the following colour Red for Chemical earthing and yellow for conventional earth pit complete all as specified and directed.
M&L for recharging of chemical earth pit by using liquid chemical earthing solution (not less than 10 Kg) and mixing with water and filling into the chemical earth pit to achieve result earth value less than 1 Ohm, complete all as specified and directed.
M&L for recharging of conventional earth pit by using salt (not less than 20 Kg) and mixing with water and filling into the earth pit to achieve result earth value less than 5 Ohm, complete all as specified and directed.
S&F Pre- cast RCC earth pit with cover incl watering funel and wire mesh as per sample and including dismantling/taking out of old unserviceable of any position complete all as specified and directed.
Comprehensive maintenance/servicing of RO plant 50 / 60 LPH capacity including washing, cleaning of sedimentation filter, disinfection process, servicing of pressure pumping set, and if any other required minor spare parts i.e RO connection pipe with fixing accessories, RO plug charger, wire , screw, nut, bolts etc at site for smooth functioning of RO plant shall be provided by contractor without any cost . Seting the PH, TDS of water at permissible level including testing of water after repair of RO plant complete the satisfaction of Engr-in-Charge. Note:- (a) Defective major components/spares if required to be replaced shall be measured and paid as supply only under respective item 86 to 98 here-in-after and labour element included in this item for replacement . (b) The rate quoted by the tenderer includes cost of maint / servicing of above said each plant ones in a quaterly visits and emergency callout as when required till the date of completion of work. (c) Servicing should be done by OEM/authorized agency and not by any local mechanic. (d) Unwanted delay in attending/ rectification of complaint if noticed the recovery shall be made Rs 500/- per day from contractor bill till complete the job
Supply only sediment filter 6000 ltr water filtration capcity as per exiting sample for 50/ 60 LPH RO plants.
Supply only PP filter 6000 ltr water filtration capcity as per exiting sample for 50/60 LPH RO plants.
Supply only RO membrane 300 LPD water filtration capcity as per exiting sample for 50/60 LPH RO plant.
Supply only RO membrane 1812 with housing as per exiting sample for 50/60 LPH RO plant.
Supply only RO membrane housing as per exiting sample for 50/60 lts RO plant.
Supply only carbon filter as per exiting sample for 50/60 ltrs RO plant
Supply only low pressure /High pressure DC switch for 60/50 RO plant.
Supply only stainer as per exiting sample for 50/60 Ltrs RO plant.
Supply only SMPS as per exiting sample for 50/60 Ltrs RO plant.
Supply only antiscalant chemical for 50/60 ltrs Plant
Supply only solenoid valve as per exiting sample for 60/50 ltr RO plant.
Supply only TDS adjuster as per exiting sample for 50/60 Ltrs RO plant.
Supply only booster pump 24/48V DC as per exiting sample for 50/60 Ltrs RO plant.
Supply only controler as per exiting sample for 50/60 ltr plant.
Disconnecting electrically, taking down and removing carefully the existing ceiling fans, exhaust fans, wall bracket fans, etc. of any description, and any position for repairs/ servicing/overhauling /painting/numbering, etc. including dismantling and opening of the fans, checking serviceable parts, overhauling by necessary cleaning, oiling, greasing, etc. and fixing the serviceable parts in position, removing and replacement of defective/ unserviceable parts if any with new parts, re-assembling the fans, making necessary adjustment and proper alignment of blades, hanging/fixing the repaired fans in position including provision of suitable three core flexible copper wire upto 1.0m length and providing new safety pins and lock nuts at the same position and testing at site to the entire satisfaction of Engineer-in-Charge complete all as directed. Note : (a) Rewinding, replacement of unserviceable parts such as bearing, GM bush, capacitor shall be measured and paid separately under respective items. (b) Contractor’s quoted rates is deemed to include for inspection/checking the serviceability of the fans in position or by taking down as per site requirement, removing the damaged unserviceable/broken parts, fixing the fans in same position or the other, connecting the fan with electric source and testing complete all as specified and directed.
M & L for rewinding of ceiling fan motor with appropriate size super enameled copper wire including insulating material such as illuminous paper, letherized paper, cotton tape, glass sleeving, insulating varnish, etc. connecting to electric source and testing on full load to the entire satisfaction of Engineer-in-Charge Note:- Taking down & refixing of ceiling fan after winding, painting and replacement of bearing, bush, capacitor etc. will be measured & paid separately.
All as per Serial item No. 100 here-in-before but for desert cooler blower motor 1275 RPM of any capacity
All as per Serial item No. 100 here-in-before but for exhaust fan motor of 300/450mm sweep any type.
All as per Serial item No. 100 here-in-before but for wall fan motor of 400mm sweep any type.
All as per Serial item No. 100 here-in-before but for pedestal or air circulator fan motor of any sweep.
Supply & fixing in repair of Ball bearing suitable size to the existing ceiling fan, Exaust fan, wall fan of any type complete all as specified and directed.
Supply & fixing in repair ceiling fan capacitor of 2.5 MFD capacity complete all as specified and directed.
Supply & fixing in repair Exaust fan capacitor 3.25/ 4.0 MFD capacity complete all as specified and directed.
Supply & fixing in repair of hanging assembly set comprising with rubber reel, MS clamps, nuts, bolts with one lock hole and lock pins suitable to ceiling fans down rods complete all as specified and directed.
M& L for Painting of old ceiling fans/Exhaust fan of any size complete, in situ with synthetic enamel paint by praying including filling cavities with filler, one coat after cleaning all dust etc. writing the fan numbers/MES numbers etc with black paints complete all as specified and directed.
S & F in repair wall/exhaust fan blade any sweep as per existing sample complete all as specified and directed.
S & F in repair ceiling fan blade any sweep as per existing sample complete all as specified and directed.
Supply & fixing in repair ventilation fan PVC 200/300 mm sweep complete all as specified and directed
Supply & fixing in repair MS 600mm long ceiling fan down rod 20mm dia as per sample complete all as specified and directed.
Supply & fixing in repair thermostat for water heater (Geyser) 25/50 Ltrs capacity as per sample complete all as specified and directed.
Supply & fixing in repair heating element for water heater (Geyser) 25/50 Ltrs capacity as per sample complete all as specified and directed.
S & F in repair geysers PVC pipe connection hot/ cold type, 15mm bore 600mm long having brass nuts and washers on both ends complete all as specified and directed.
Testing of Bore well water/ RO water to analysis the following parameter as per IS 10500 : 2000 through Govt. approved agency:- (a) Physicochemical parameters of water/ eflluent sample (b) Bactoriological test of water sample. (c) Metals (Expect Hg, As & Se). (d) Pesticides.
Servicing and non comprehencive annual maintenance of RO plant of 5000 ltr/hr capacity (Make-ion exchange) with authorised service provider of ion exchange. Note:-1- This include visit of the technician of ion excahnge every month in any working days and look the performance, back wash the filter at regular intervals, check the anti scalant and add the chemical as required,cleaning of sediementation filter,cleaning of cartridge and membrane,check of control panel and system pressure and RO element for proper operation of the system, Seting the PH, TDS of water at permissible level including testing of water after repair of RO plant complete the satisfaction of Engr-in-Charge. Note:- (a) Defective major components/spares if required to be replaced shall be measured and paid as supply only under respective item 119 to 130 here-in-after and labour element included in this item for replacement . (b) The rate quoted by the tenderer includes cost of maint / servicing of above said each plant ones in a month visits and emergency callout as when required till the date of completion of work. (c) Servicing should be done by OEM/authorized agency and not by any local mechanic (d) Unwanted delay in attending/ rectification of complaint if noticed the recovery shall be made Rs 1000/- per day from contractor bill till complete the job.
Supply only Jumbo filter 20" for 5000 Ltr RO plant complete all as specified and as directed.
Supply only anti-scalanent chemical for 5000 Ltr RO plant complete all as specified and as directed.
Supply only membrane hydra for 5000 Ltr RO plant complete all as specified and as directed.
Supply only UV lamp for 5000 Ltr RO plant complete all as specified and as directed.
Supply only UV system for 5000 ltr RO plant complete all as specified and as directed.
Supply only multi port valve suitable for existing 5000 Ltr plant complete all as specified and as directed.
Supply only high pressure switch suitable for 5000 ltrs RO plant complete all as specified and as directed.
Supply only low pressure switch suitable for 5000 ltrs RO plant complete all as specified and as directed.
Supply only solenoid valve for 5000 Ltr RO plant complete all as specified and as directed.
Supply only multi filter housing suitable for existing 5000 ltr RO plant complete all as specified and as directed.
Supply only controler suitable to existing 5000 ltr RO plant sample complete all as specified and as directed.
Supply only vessel of existing make suitable for 5000 ltrs RO plant complete all as specified and as directed.
S & F in repair of dosing pump suitable for existing 5000 ltr RO plant complete all as specified and as directed.
M & L for topup and filling of 2mm size quartz sand in pressure water sand filter complete all as specified and directed.
M & L for taking out of old blocked Carbon and filling of new activated carbon as per sample in exiting carbon filter complete all as specified and directed.
S & F in repair of old unserviceable 20 mm bore "medium grade" galvanised iron pipes with all fittings complete to walls and ceilings or laid in floors /trenches complete all as specified and directed. Note:- Excavation/ earth work will be measured and paid separately under respective items.
All description as per item No 134 here-in-before but for 25mm GI bore pipes.
All description as per item No 134 here-in-before but for 50mm GI bore pipes.
All description as per item No 134 here-in-before but for 80mm GI bore pipes.
S & F in repair of old unserviceable 20 mm dia CPVC pipes SDR 11 with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed. Note:- Excavation/ earth work will be measured and paid separately under respective items.
All description as peritem No 138 here-in-before but 25 mm bore CPVC pipes SDR 11 with fittings.
S & F in repair Pressure gauge 4" dial 0-14 kgs rating complete all as specified and directed.
S&F in repair Foot Valve made of cast iron material one side flange end and other side strainer and floating reinforced rubber coated ball as per existing sample for 80/100 mm dia pipe complete all as specified and directed.
Supply only Calcium Hypo Chlorite 65 to 70% (calcium based granular) disinfectant for water treatment is sealed packing of 45 Kg HDPE jars to MES store yard as directed by Engr-in-Charge. Make of product : As per approved by E-in-C Branch or earlier guide line/policy letter.
S & F in repair chlorine dosing FRP service tank 100 Ltr capacity consisting of level gauge, water inlet & outlet line, strainer, drain etc including agitator complete all as directed. (Make : Jesco, Aquafit, Declibac or equivalent as approved by GE.)
Taking out the broken, rusted, valve pit cover of any size and M & L for fixing valve pit cover of suitable size to existing made of 3 mm thick MS sheet/plate including provision of hinges, handle and locking arrangement including 40 x40 x 4mm iron frame fixed or top of valve pit, including two coat of anti-corrosive paint over a coat of red oxide primer complete all as specified and as directed.
M & L of CI/DI fittings upto 250mm bore such as bends (any type radius and angle) Tappers (any type straight, bend, increasing, decreasing or double socket etc),Tee ,single branch, Y junction, double branch, connecting pieces one end flanged and other socket or spigot and bell mouth pieces, Collars, Caps and plugs etc or including dismantling old one complete all as specified and as directed.
S&F in repair 150mm dia DI pipe with DI pipe (spun) 150mm dia class K7 in any length with special fitting laid in trenches/surface complete all as specified and as directed . Note :- Earth work will be measured and paid separately under relevant item of sch.
M&L for disconnecting electrical/ mechanical connection and taking out submersible pump set from existing bore well approx depth varying from 110 m to 130 m with all accessories and transporting to authorized workshop for rewinding and overhauling of sumbermersible pump and after overhauling / rewinding, re-lowering the pump set in bore well with all accessories, including making connection with existing starter and testing to ensure efficient and smooth functioning to obtain required discharge, etc complete all as specified and directed.
M & L for rewinding of 3 Phase, 25/35 HP submersible electric motor with PVC insulated copper winding wire of same gauge including impregnated paper, sleevs, lathorised fibre glass, and tape, thrust bearing, and bush etc. complete all as specified and directed.
M & L for overhauling and repairing of submersible pump assembly of 10 to 16 stage with replacement of defective parts such as gun metal bush, rubber bush, CI neck ring, pump shaft, bowl case & impeller etc as required at site including necessary lath work, metaling, turning, poloshing, and reassemble all the parts and refixing at same position complete all as specified and directed.
S & F in repair 80/100 mm bore heavy grade MS/ GI column pipe in 3 meter length with welded socket complete all as specified and directed.
Comprehensive maintenance and servicing of chlorine dosing equipment self priming, having discharge capacity up to 5 Ltrs/ Hour of any make and carry out repair/replacement of defective minor spares parts i.e. spring, oil seal, pan head screw, circlip, Stroke knob and nut, bolt and washer etc. including cleaning, washing / reassembling the plants and testing after repair complete all as specified and as directed by Engr-in-charge. Note : (i) Defective major components/spares if required to be replaced shall be measured and paid as supply only under respective item 153 to 154 here-in-after and labour element included in this item for replacement. (ii) All items being spare parts as under will be replaced as required as per cat part or as per existing sample to shoot the equipment for smooth functioning. (iii) The rate quoted by the tenderer includes cost of maint / servicing of above said each plant ones in a quarterly visits and emergency callout as when required till the date of completion of work.
Supply only PVC diaphragm with 'O' ring head for chlorine dosing.
Supply only suction/ discharge /non return valve up to 5 ltrs/Hr for chlorine dosing pump.
S & F in repair PVC insulated and FR PVC Round Sheathed, flexible Copper Conductor 0.5 Sqmm, 6/8 core control cable, 1100 Volts, conforming to IS: 694 for water level indicator fixing on wall/floor in PVC conduit or hanging in air with the help of GI wire complete all as specified and directed by Engineer-in-Charge.
S & F in repair for Water Level Indicator with Low & High Water Level Alarm conforming with 4 levels of LED indication representing 25%, 50%, 75% and 100% levels in the tank, Power ON Led indication, Audio & visual Level indication including with 4 Nos moulded silver steel contact type sensor complete suitable to existing sample complete all as specified and as directed.
S&F in repairs Gun-metal, globe or gate valves of size 20 mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S&F in repairs Gun-metal, globe or gate valves of size 25 mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S&F in repairs Gun-metal, globe or gate valves of size 40 mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S&F in repairs for Gun-metal, globe or gate valve of size 50mm dia, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S&F in repairs for sluice valve 100 mm bore cast iron flanged and drilled both ends (ISI marked) Class PN-1.6, Non Rising stainless steel spindle complete all as specified and as directed.
S&F in repairs for sluice valve 150 mm bore cast iron flanged and drilled both ends (ISI marked) Class PN-1.6, Non Rising stainless steel spindle complete all as specified and as directed.
Supply & fixing in repair non return sluice valve suitable for 100 mm dia pipe complete all as specified and as directed.
Supply & fixing in repair butterfly valve (wafer Type), PN-1.6 with S/S Disc, neoprene rubber Lining, lever operated and S.G. Iron body suitable for 100 mm dia pipe complete all as specified and as directed.
Supply & fixing in repair butterfly valve (wafer Type), PN-1.6 with S/S Disc, neoprene rubber Lining, lever operated and S.G. Iron body suitable for 80 mm dia pipe complete all as specified and as directed.
S&F in repair CI air release valve complete all as per existing sample complete all as specified and as directed.
M & L for repair to joint leakage of DI pipe line of 100 mm to 150mm dia, by cocking and inserting extra lead/gasket/ rubber sheet clamp , nut bolts etc. and any other material required at site for making good/ leakless the existing joint, including necessary excavation and earth work, returning filling after testing the joint complete all as specified and directed.
M & L for repair in leakage/ blocked GI water tubing of size 15 mm to 40 mm by using pipe nipple, union, coupling etc. and any other material required at site for making good/ leakless the existing joint, including necessary excavation and earth work, returning filling after testing the joint complete all as specified and directed.
M & L for repair in leakage/ blocked GI water tubing of size 50 mm to 80 mm by using pipe nipple, union, coupling, etc. and any other material required at site for making good/ leakless the existing joint, including necessary excavation and earth work, returning filling after testing the joint complete all as specified and directed. Note for Item Ser No 167 to 169:- If not attending/ rectification of complaint same day if found noticed the recovery shall be made Rs 500/- per day from contractor bill till complete the job.
M & L for making serviceable old UNSV Motor starter of any type carrying out repair and with replacement of defective spare parts except contactor including testing to ensure efficient and smooth functioning of starter complete all as specified and directed.
Cleaning of fire water static water tank of capacity 20000 litre at sector-27 area, by draining out storage water completely with mud pump or throeing out manually with buckets and cleaning of inner surface of bottom and walls of tank by removing complete accumulated sludge/ mud, dirt etc with depositing distance not exceeding 50 metre complete all as specified and as directed.
Cleaning of clear water semi underground sump of capacity 25000 Gln at sector-27 pumphouse, by draining out storage water completely with mud pump or throeing out manually with buckets and cleaning of inner surface of bottom and walls of tank by removing complete accumulated sludge/ mud, dirt etc with wire brush and finally washing with fresh water and disinfecting the reservoir with 2% solution of potassium permaganate including writing date of cleaning with white synthetic enamel paint and removing sludge scale mud etc to a distance not exceeding 50 metre and depostting complete all as specified and as directed.
Cleaning of RCC overhead reservoir of capacity 25000 gallons at 20 metre staging, by draining out storage water completely with mud pump or throwing out manually with buckets and cleaning of inner surface of bottom and walls of tank by removing complete accumulated sludge/ mud, dirt etc with wire brush and finally washing with fresh water and disinfecting the reservoir with 2% solution of potassium permaganate including writing date of cleaning with white synthetic enamel paint and removing sludge scale mud etc to a distance not exceeding 50 metre and depositing complete all as specified and as directed.
M & L for disconnecting and taking up/down 5.0/7.5 HP capacity centrifugal /mono-block pump set of any type from foundation and transporting to authorized workshop carry out repairs such as replacement of pump bearing and overhauling including replacement of minor unserviceable components/spares like 'O' rings, Oil seal, Mechanical seal, pump gland, casing ring, gasket packing and greasing, welding, metaling, turning, polishing, Lathe work etc. along with removing existing burnt/short circuited winding wire complete, cleaning of core grooves and surfaces, rewinding the motor with superior quality enameled copper winding wire of suitable gauge, numbers of turns and coils including insulating material such as sleeves, lathorised fibe glass, cotton/PVC tape varnishing etc, reassembling, refixing and testing the motor at site on full load complete all as specified and directed by Engr-In-Charge.
S & F in repair motor starter with relay range 9-14 Amps in sheet metal enclosure type with Ammeter and voltmeter AC-3 phase, 415V, 50 Hz suitable for 5 HP electric motor complete all as specified and as directed.
S&F in repair of 3 layer borosilicate glass tube with silicon ring suitable to existing sample tube type solar water heaters complete all as specified and as directed.
S&F in repair of 3 KW electric back up heater with thermostat (ISI approved) with pressure release valve 31.75 mm dia complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m width and not exceeding 1.5 m in depth and getting out in soft/ loose soil for taking up/ laying cable/pipe etc complete all as specified and as directed.
Returning, filling including spreding, leveling watering & well ramming in laying not exc. 25cm for soft/ loose soil complete all as specified and as directed.
Removal of excavated material at a distance not exc 50 mtr and dipositing where directed at a level not exc. 1.5 mtr above the starting point for soft/ loose soil complete all as specified and as directed.
M&L for dry sand cushioning to underground cable with screened, washed river sand, including punning gently complete all as specified and as directed. Note:- Thickness after punning will be measured for payment.
Supply and lay burnt brick sub class `B' old size in trenches abouting each other width equal to length of brick etc complete all as specified and as directed.
Laying only burnt bricks (old size) retrieved from respective items, laid in trenches as cable protection complete all as specified and as directed.
Supply and laying in trenches in road cross/ floors tube galvanised iron light grade 40mm bore with all fittings for protection of cable complete all as specified and as directed.
Labour only for boring under road/ drain by manual method for inserting the light grade pipe GI tubing up to 50 mm dia cable protection complete all as specified and as directed by Engineer In Charge.
Disconnecting, taking out and removing old existing unserviceable underground, LT aluminium conductor cable of size 10 to 35 Sqmm of any core complete all as specified and as directed by Engineer In Charge.
Disconnecting, taking out and removing old existing unserviceable underground, LT aluminium conductor cable of size 50 to 95 Sqmm of any core complete all as specified and as directed by Engineer In Charge.
Disconnecting, taking out and removing old existing unserviceable underground, HT aluminium conductor cable of size 95 Sqmm 3 core complete all as specified and as directed by Engineer In Charge.
Laying only serviceable XLPE / P.V.C insulated, armoured, heavy duty, aluminum conductor cable of 1100/11000 volts grade of any description and any make laid in trenches/ducts, floors, on pole, walls etc. complete all as specified and directed by the Engineer-in-charge for the following sizes :- (NOTE : (i) Old retrieved cables received in serviceable condition from taking down shall be used in the work (ii) Additional quantity of cable, if any required, for replacing the defective portion of cable retrieved from dismantling /taking out, shall be measured and paid separately under respective items.
LT U/G cable of 10 Sqmm to 35 Sqmm any core.
LT U/G cable of 50 Sqmm to 95 Sqmm 3½ core
HT U/G cable of 95 Sqmm 3 core
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 sq. mm complete all as specified and as directed.
Supply, laying and testing cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with stranded aluminum conductor, 1100 Volts grade, of size 95 Sqmm 3.5 Core complete all as specified and as directed. Note:- Excavation, earthwork, will be measured and paid separately under respective items of this Schedule.
All description as per Serial item No. 193 here-in-before but cable of size 70 Sqmm 3.5 Core
All description as per Serial item No. 193 here-in-before but cable of size 50 Sqmm 3.5 Core
All description as per Serial item No. 193 here-in-before but cable of size 25 Sqmm 3.5 Core
All description as per Serial item No. 193 here-in-before but cable of size 16 Sqmm 4 Core
All description as per Serial item No. 193 here-in-before but cable of size 10 Sqmm 4 Core
M&L for searching fault by mannualy/machine of 25 sqmm to 185 sqmm unservieable LT underground cable 1100 volt grade by excavating of soil & taking out old bricks, after tracing out defect i.e. cutting and jointing cable with suitable size straight through joint and after testing with megger etc.
M&L for searching fault by mannualy /Machine of 95 sqmm unservieable HT underground cable 11000 volt grade by excavating of soil & taking out old bricks, after tracing out defect i.e. cutting and jointing cable with suitable size straight through joint and after testing with megger etc. Note for Item No. 199 to 200 (a) If extra suitable size cable required for straight through jointing (the extra cable required length upto 3 RM) rate shall be deemed into this item rate. (b) Earth work more than two running meter shall be measured and paid separately . (c) Straight through joints will be measured and paid separately. (d) If not attending complaint within two hours or not rectification of complaint same day if noticed the recovery shall be made Rs 2000/- per day from contractor bill till complete the job.
S & F in repair for epoxy jointing kit for straight through joints of LT armoured aluminium conductor cable size 95/120 Sqmm 3.5 core 1100 volts grade cable with epoxy jointing materials complete all as specified and as directed.
All description as per Serial item No. 201 here-in-before but for LT armoured aluminium conductor cable size 50/70 Sqmm 3.5 core 1100 volts grade cable
All description as per Serial item No. 201 here-in-before but for LT armoured aluminium conductor cable size 25/35 Sqmm 3.5 core 1100 volts grade cable
All description as per Serial item No. 201 here-in-before but for LT armoured aluminium conductor cable size 10/16 Sqmm 4 core 1100 volts grade cable
S & F in repair for Cable jointing kit for 11 KV (Earthed) grade cable for indoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm to 120 sqmm complete all as specified and as directed.
S & F in repair for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm to 120 sqmm complete all as specified and as directed.
S & F in repair for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm to 120 sqmm complete all as specified and as directed.
M&L for preparation of old painted surface of steel tubular pole (upto 9 meter long above coping) with MS clamp and applying two coat of aluminium paint, making of strip of 20 cm width (sky blue and white in alternate band) upto 1400 mm height with one synthetic enamel paint complete all as specified and as directed.
Material & Labour for preparation of old painted surface of LT RCC pole (up to 6.10 metre height above coping), applying two coat snowcem cement base paint, making of strip of 20 cm width (sky blue and white in alternate band) upto 1400 mm height with one synthetic enamel paint, rewriting pole No by painter with enamel paint, and painting the existing MS clamp with one coat aluminum paint complete.
Supply and paste fluorescent type reflective tape of superior quality width 450 mm (three strips, each 150 mm wide and 600 mm long of colour white, sky blue, white), paste on steel tubular pole on outer circumferences including removing old tape complete all as specified and as directed.
M&L for writting of Pole Nos. on existing pole with stencil out with white colour in sky blue colour background of 80 mm hight around the radius of pole and complete all as specified and as directed by Engr in charge.
S&F in repair timer switch Digital type 24 hours with 15 min and 30 min, 30/100 Amp contact rating 230 volts AC 50 Hzs suitable to existing sample for street lights and complete all as specified and as directed by Engr in charge.
S&F in repair 3 pole power contactor AC 3 rating 18/25Amps Aux Contactors 2NO+2NC complete all as per existing sample
S&F in repair 3 pole power contactor AC 3 rating 32/40Amps Aux Contactors 2NO+2NC complete all as per existing sample
Disconnecting the existing unserviceable PVC box and Supply and fix PVC box of outside size 300mm x 200mm x 100mm including 4 Nos. of bus bar strip of aluminium of size 25x4 mm suitable for 440 volts of suitable amps rating including 1 No MCB SPN, 6 to 10 Amps, 250 volts with 'C' curve, to be fixed on pole with clamp complete all as specified and as directed.
S&F in repairs round PVC insulated standed copper conductor wire of 1.5 sqmm dia, 3 core from existing junction box to light fitting complete all as specified and as directed.
S&F in repair 200 Watt High-efficiency IP66 LED floodlight design in aluminium pressure die-cast housing for better heat dissipation. High lumen efficacy LED module with SMD LED package mounted with PC lens , suitable for highlighting architectural facade highmast and general purposelighting with all accessories fixed in existing channel and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and as directed.
S&F in repair LED street light fitting 80/90 watt sealed optic luminaire, indivdual optical lens, MCPCB printed circuit boards with LED driver housing made of die cast aluminium with smooth finish powder coated for better environmental protection complete all as specified and as directed.
S & F in repair of existing LED Street light 80/90 watt by replacing LED drivers or LED chip set etc. as required for making LED light fitting serviceable complete all as specified and as directed.
S & F in repair of existing LED flood light 200 watt by replacing LED drivers or LED chip set etc. as required for making LED light fitting serviceable complete all as specified and as directed.
S & F in repair MCCB of 315-400 Amps, 4 pole, 25 KA with Adjuestable thermal setting suitable for 415 Volt, 50 Hz, in existing panel with suitable size lugs , nuts, bolts and washer etc complete all as specified and as directed.
S & F in repair MCCB of 200-250 Amps, 4 pole, 25 KA with Adjuestable thermal setting suitable for 415 Volt, 50 Hz, in existing panel with suitable size lugs , nuts, bolts and washer etc complete all as specified and as directed.
S & F in repair MCCB of 125-160 Amps, 3 pole, 25 KA with Adjuestable thermal setting suitable for 415 Volt, 50 Hz, in existing panel with suitable size lugs , nuts, bolts and washer etc complete all as specified and as directed.
S & F in repair MCCB of 63-100 Amps, 3 pole, 25 KA with Adjuestable thermal setting suitable for 415 Volt, 50 Hz, in existing panel with suitable size lugs , nuts, bolts and washer etc complete all as specified and as directed.
Disconnecting existing over heated or burnt cable terminal at existing panel/ Junction box and cutting out over heated / burnt portion of cable, stretching / opening cable to suitable required length from available rings and reconnecting cable in position properly with providing new lugs, tapes etc for cable size upto 95 sqmm complete all as directed
M & L for preparation of old painted surface of electrical panel inner and outer surface complete of size length(0.5 to 1 m), Height (1 m to 2 m) and Breadth (upto 0.5 m) by scrubbing old paint and applying two coats of synthetic enamal paint with spray machine complete all as specified and as directed.
M&L for preparation of old painted surface of electrical panel inner and outer surface complete of size length (1 m to 2 m), Height (1 m to 2 m) and Breadth (upto 0.5 m) by scrubbing old paint and applying two coats of synthetic enamal paint with spray machine complete all as specified and as directed.
Replacement of existing unserviceable/damaged part / portion of the existing feeder pillar box / panel boards with supplying and fixing new part or portion fabricated out of 3mm thick MS sheet in position including making necessary adjustments and alignments to make the existing feeder pillar box/ panel board body to required shape(s) and size(s) complete all as specified and as directed. NOTE : (i). The panel board repaired shall be made totally enclosed, weather proof for MCCB & cable etc. (ii) The rates quoted by the contractor are deemed to be with and including necessary cutting, welding, grinding and jointing etc. as directed to match & accommodate with the existing feeder pillar box / panel board . (ii) The replaced portion shall be painted with two coat of synthetic enameled paint over a coat of red oxide primer.
S & F in repair LT panel sliding door lock chromium plated or as per existing sample complete all as specified and as directed.
Comprehensive Maintenance/ Servicing of existing1IC + 3 OG RMU's SF 6, 3 phase, 11 KV, 630/ 400 Amps by authorised dealer only. The scope of work includes:- (a) Calibration of metering system, checking, setting, adjustment of over current relay, earth fault and tripping relay complete all as specified and directed by Engr in charge. The contractor should immediately approach mechanic of authorised dealer as soon as fault occurs/ resetting required. (b) Checking of all incoming and outgoing HT Terminals for any looseness and ensuring the proper tightness for all terminals. (c) Checking the nominsl operating gas presssure as per manufactures standard of RMU and testing for any leakage of insulation gas and rectify the same if found (d) Operating gas pressure should be suitable to satisfy the rated dielectric strength (e) Testing for CT's, PT's, Relays, Breakers and cable glands (f) Anti oxide greasing should be done at all connections of cable and bus bars Note:- (1) The contractor should ensure the proper functioning of RMU's and should approach with authorised dealer for carrying of servicing of breaker periodically & when fault /breakdown occurs. (2) Contractor shall produce all purchase voucher and test certificate before submitting the RAR. (3) The contractor will be responsible for serviceability of RMU's for the entire contract period (4) Unserviceable Spare Part will be paid and measured separately under respective items of schedule.
Servicing of transformer upto 500 KVA/250 KVA at carrying out insulation resistant test (HT-LT, HT-E & LT-E), BDV of Oil (top & bottom sample), Filtration & topping up of oil, test, quaterly resistance check of earth pits, arresting of leakage by proper tightening of terminals & joints, replacement of loose or burnt out gasket & proper sealing of valves etc complete all as specified and as directed by Engineer-in-Charge. Notes:- (i)The cost involved for oil filtration & topping with new mineral oil will be measured & paid separately. (ii) The contractor should produce all testing certificates immediately after testing. Moreover testing should be carried out by authorized OEM only. (iii) The contracted labour manning the substation should immediately inform any oil leakage, change in colour of silica gel, level down of oil in conservator etc.
Dehydration/ filtration of transformer oil of transformers, of various capacities installed in different locations under GE ( AF ) chiloda, by recirculation existing transformer oil with trolley mounted filtration plant till dielectric strength is up to 40 KV to 50 KV. Note:- Quoted rates shall be deem to include for following:- (i) Contractor shall be submite the recorded test results before & after filtration of oil. (ii) Contractor should make his own arrangement for oil filtration plant including transportation complete. (iii) The contractor solely responsible for any damage to the transformer during filtration operations. He is responsible for making good any damage to the transformer at his own cost without any extra cost to the department. (iv) The contractor shall ensure that the conservator tanks are full to its level before starting the dehydration.
Supply, filling and topping up the transformer/Voltage stabilizer with dielectric strength 50 KV new transformer oil duly filtered with filtration plant. Note:- (a) The transformer oil shall be type EHV confirming to IS 3357 of 1983
S&F in repair worn out HT terminal with bush of existing size for transfomers upto 500 KVA capacity to arrest leakage by opening top cover and refixing the same with replacement of worn out gasket complete all as specified and as directed.
S&F in repair worn out LT terminal with bush of existing size for transfomers upto 500 KVA capacity to arrest leackage by opening top cover and refixing the same with replacement of worn out gasket complete all as specified and as directed.
S&F in repair transformer breather silca jel complete all as specified and as directed.
M & L for isolating the HT supply of transformer, disconnecting HT and LT connecting of transformer and isolating the cables from transformer indoor/outdoor of 250 KVA to 500KVA capacities checking of transformer diaphragm oil condition and carrying out necessary tests for finding fault such as megger test, ratio test, magnetic balance test. Short circuit test including opening the lid after draining out oil as required to check the lead connection from winding to bus rods including necessary soldering/ jointing etc and after repair charging of transformer and testing complete all as specified and directed.
Material and labour for preparation of old painted surfaces of floor mounted transformer of 250 to 500 KVA capacity by cleaning/rubbing to remove dust , oil , grease deposits and painting with two coats of synthetic enamel paint complete including writing the SM No / MES No on transformers with white paint in the existing style/pattern complete all as specified and as directed.
Comprehensive maintenance and servicing of DG sets of capacity 75/200 KVA of any Make with general maintenance work such as, checking of controller error, adjustment of fan belt, valve clearance, hose pipe, battery terminal etc. replacement of defective/worn out parts by new spares such as filters, Engine oil, coolent, etc including cleaning, greassing and testing after repair complete all as directed.
All description as per Srl item No 239 above but for DG set of 10 to 20 KVA capacity Note for Item No 239 & 240 :(i) Defective major components/spares if required shall be measured as Supply only under respective item 244 to 251 here-in-after and labour element included in this item for replacement . (ii) All the repair carried out at the concern installation or if required in worksshop and spare parts as under will be replaced as required as per cat part or as per existing sample to shoot the equipment for smooth functioning..
Supply only fuel filter (Primary and baby) element with O rings for 75/200 KVA capacity DG set
Supply only fuel filter element with O rings for 10/20 KVA capacity DG set
Supply only engine oil filter with O rings for 75/200 KVA capacity DG set
Supply only engine oil filter with O rings for 10/20 KVA capacity DG set
Supply only air filter element as per sample
Supply and filling in sump/toping up multi grade engine oil
Supply and filling coolent in DG set radiator
Supply and filling Electrolite of specific gravity in lead acid batteries of DG set
S & F in repair Door lock for canopy type DG set complete all as specified and as directed.
S & F in repair fan belt suitable for 75 to 200 KVA capacity DG set (as per existing sample) complete all as specified and as directed.
S & F in repair radiator ruber hose pipe with clamp suitable for 75 to 250 KVA capacity DG set (as per existing sample) complete all as specified and as directed.
S & F in repair old unsv battery brass terminal (as per existing sample) complete all as specified and as directed.
S & F in repair old unsv DG set battery lead PVC insulated multi stranded copper conductor (as per existing sample) complete all as specified and as directed.
M & L for disconnecting of radiator from 75 to 200 KVA DG set and transporting to authorized workshop to carry out repair i.e cleaning descaling with restore plus solution,removal of leakage, welding brazing and re-fixing it at site and testing after repair complete all as specified and as directed.
M&L for repairing and overhauling of 12/24 volts self starter including replacement of flywheel ring carbon bushes,bearing bushes,re-winding of armature and filled and warnishing complete all as specified and as directed.
S & F in repair AMF panel battery charger of DG set as per existing sample complete all as specified and as directed.
M & L for disconnecting unserviceable fuel injection pump of any type from DG set with disconecting of fuel injector pipe and transporting to authorised work shop for necessary repairing and after repair calibration the fuel injection pump till the required results and fixing the same after repair complete all as specified and directed by Engr-in-charge.
S & F in repair battery 12 volt, 180AH, 2 year warranty complete all as specified and as directed.
Repairs maintenance of APFC panel of capacity 90 KVAR to 250 KVAR including replacement of burned cable with lugs, insulator, MCB etc calibration of relay, digital meter including testing complete all as specified and as directed. Note:- Unserviceable Spare Part will be paid and measured separately under respective items.
S & F in repair APFC panel controller for contactor switching with CT input suitable to existing sample complete all as specified and directed.
S&F in repairs 25 KVAR cylindrical capacitor, 440 volts, 3 phase, 50 Hz complete all as specified and as directed by Engr-in-Charge.
S & F in repair volt meter 0 to 500Amp 3 phase as per existing sample complete all as specified and as directed.
S & F in repair 3 phase Ammeter as per existing sample rating complete all as specified and as directed.
M & L for replacement of indication lamps with LED type indication lamps with showing red, yellow and green colours suitable for 240 Volts AC supply as per existing size complete including connection complete all as specified and as directed.
S & F in repair LT CT as per existing sample rating complete all as specified and as directed.
S & F in repair of RMU HT CT 30/60 ratio as per existing sample complete all as specified and as directed.
UMIYA BUILDCON
Dighard Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .