Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.0 CrAccepted-AOC ERNAKULAM KERALA 682301 INDIA | ERNAKULAM | KERALA | 682301 | ₹4.0 Cr | 1 | Accepted-AOC Single Bidder approved by CE level committee |
Tender Value
₹4.1 Cr
EMD Value
₹8.3 L
Closing Date
12 Jun 2024, 4:00 pmClosed
O/o the DyCE, Ele. Circle Palakkad,VB Palakkad
DyCE, Ele. Circle Palakkad,VB Palakkad
INSTALLATION OF RMU 11 KV -CTC, INSTALLATION OF RMU 11 KV -Add on C ,INSTALLATION OF RMU 11 KV-Add on T ) UNDER RDSS_Electrical Circle,Palakkad.
2024_KSEB_673167_1
KSEB/EC-PKD/RDSS/ E-TENDER/ 05 /2024-25/ Dtd 21.05.2024
Open Tender
Electrical Works
Turn-key
314 days
Under Electrical Circle Palakkad
Refer tender documents
8 documents required · 8 mandatory
₹8,850
₹8.3 L
O/o the DyCE, Ele. Circle Palakkad,VB Palakkad
16 Aug 2024
21 May 2024
15 Jun 2024
21 May 2024
12 Jun 2024
21 May 2024
21 May 2024 - 24 May 2024
24 May 2024
BOQ - 1 - Installation & Commissioning of SCADA compatible Extensible RMUs of various configarations
11kV 630 A SCADA compatible Extensible RMU CTC - Load break switch 2 nos & VCB 1 No
11kV 630 A SCADA compatible Extensible RMU Add on T - VCB 1 nos
11kV 630 A SCADA compatible Extensible RMU Add on C-Load break switchs 1 nos
CROSS ARM GI CHANNEL 100mmX50 mmx6mm
GI Pipe Earthing set includes 1. GI STRIP 32 X 6 MM 2. Pipe GI 40 mm dia - 2.5 m Length( Earth Pipe) 3. Earth Chamber (RCC) With RCC Covering Slab etc.as required as per technical specification, approved drawings and scope of work.
Bolt & Nut GI of various sizes as per requirement
Cable End Termination Kit 11 kV XLPE 3c x 300 Sq.mm -Heat Shrinkable
RDSS sign Board as per approved spec
Description of Work / Item(s)
BOQ - 2 - RMUs - Installation & Commissioning of SCADA compatible Extensible RMUs of various configarations
RMUs : Installation & Commissioning of SCADA compatible Extensible RMUs of various configurations - Cost of construction of foundation as per approved drawings, base plates, fixing anchor bolts, handling, erection, alignment and allied works for the installation of Data Aquisition compatible Extensible type Ring Main Units with terminal protector boots & extension modules, actuators for remote operations, communicable FPIs, CTs, PTs & relay contacts for SCADA, giving power & control wiring and connections, providing terminal protector, interconnecting RMU bus bar and control cables, providing metered LT supply from nearest LT pole if required, providing earth leads, cable mounting & terminations, giving connections after ascertain proper phase sequence, providing location name & warning boards and RDSS signboards, burying cables & refilling, conducting all pre commissioning tests as required, complete.
11kV 630 A SCADA compatible Extensible RMU CTC - Load break switch 2 nos & VCB 1 No
11kV 630 A SCADA compatible Extensible RMU Add on T - VCB 1 nos
11kV 630 A SCADA compatible Extensible RMU Add on C-Load break switchs 1 nos
Mounting and connecting HT XLPE UG cable ends of all sizes upto and including 3x300 sq mm with special type cable clamps, bolts, nuts, terminal protectors etc.including cost of extra materials if needed and giving necessary jumper connections.
Doing one cable end termination on HT XLPE UG cables of sizes beyond 3x185 sqmm and upto and including 3x300 sq mm using the cable jointing kit after making fencing,caution board and all other safety measures including charges for cable jointer etc. complete as per the direction of the departmental officers.
Providing one Earth as per spec and approved drawing , using GI earth pipe of size 40mm dia,2.5 m length including digging separate pit (0.45X0.45X2.5 m) at standard distance (1.5m) away from the pole/structure in all classes of soil and backfilling the pit with Bentonite powder and other accessories for improving earth resistance and providing earth chamber with covering slab complete.(includes the cost of adeqaute earth enhancing compound- Bentonite powder etc)
Providing RMU fencing using steel work using 40 mm Dia GI pipes for verticals & outer frame of gate, providing gate with locking arrangements, with two horizondal bracings using 40 x 6 mm MS flat & grills with MS rods 8 mm Dia @ 10cm c/c for verticals for the gate, providing danger board & name board, fixing in position, concreting the base with 1:2:4 CC, applying one coat of zinc chromate primer and two coats of aluminium paint for fencing post and gate frame, providing fencing with 4 mm GI chain link fixed to GI post, as per detailed specifications including all charges
Cleaning and levelling of transformer yard/RMU, spreading 40 mm broken stone in yard for a thickness of 10 cm above bed of 10 cm thick 6 mm broken stone, after constructing a curb wall of height 20cm above ground and 10cm below level including cost of all materials and charges for conveying, spreading, consolidating etc.
Description of Work / Item(s)
Total Amount excluding GST of BoQ1 (Plant and Equipment)
Total Amount excluding GST of BoQ2( Installation /Erection charges)
Total Amount excluding GST of BoQ1 +BoQ2
Unconditional Discount Offered by the Bidder (if any) in Rs
Grand TOTAL (Sl.No.3-Sl.No.4)
Grand TOTAL including GST (Sl.no 5 + Total GST of BOQ1 + Total GST of BOQ2)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .