| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 LAccepted-AOC 224 OFFICERS ENCLAVE BEHIND PLV MEMORIAL COLLEGE SHIKARGARH ARMY AREA JODHPUR RAJ 342001 | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC M/S Hariom Construction Company is the Lowest Bidder, hence accepted. | |
| 2 | L2₹4.1 L+₹48,552 (13.5%)Rejected-Finance 77 KAILASH PURI BIKANER RAJ C 15 SWC JAIPUR | BIKANER | RAJASTHAN | 331801 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹4.2 L+₹58,566 (16.3%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | Rejected-Technical 77 KAILASH PURI BIKANER RAJ C 15 SWC JAIPUR | BIKANER | RAJASTHAN | 331801 | - | Rejected-Technical Not enlisted in appropriate category i.e. c (i). Hence, rejected. |
Tender Value
₹4.5 L
EMD Value
₹8,920
Closing Date
28 Mar 2024, 6:00 pmClosed
Shri Nitish Pathak,EE
GE(AF) Phalodi
REPAIR/MAINT OF AIR CONDITIONERS AND CONNECTED ITEMS AT AF STATION PHALODI
2024_MES_643900_1
8554/A/E8
Open Tender
Civil Works
Item Rate
120 days
Air Force Station Phalodi
As per tender documents
7 documents required · 7 mandatory
₹500
GE(AF) Phalodi
₹8,920
Yes
9 Apr 2024
23 Feb 2024
29 Mar 2024
23 Feb 2024
28 Mar 2024
15 Mar 2024
Amount
M&L for servicing and maintenance of split type AC's of capacity 1 TR/ 1.5 TR/ 2.0 TR comprising of the following works & installed at different locations including testing, painting of outdoor unit including writting MES Nos with black synthetic enamel paint (height of letters not less than 10mm) on indoor and outdoor unit complete all as specified and directed :- (i) Checking and rectifying the Indoor/outdoor units for noise free operation. (ii) Checking and rectifying the electrical connection for tightness. (iii) Cleaning the Out-door unit condenser and In-door unit cooling coil with air blower and latest technology cleaning system. (iv) Greasing/Oiling of condenser fan motor and blower motor. (v) Checking and rectifying for any kind of refrigerant leakage. (vi) Checking the serviceability of remote control unit. Note:- (i) Any parts found unserviceable/defective rectified/changed shall be measured and paid separately under respectively item (here-in-after) of BOQ. (ii) Make of parts shall be as per original & Genuine make of AC. (iii) Make(s) of AC's to be repaired are specified in Appx 'B'. (iv) Providing Common tools, Special Tools, latest cleaning devices and Connected accessories is the responsibility of contractor.
All as per Srl Item No 1.00 (here-in-before) but for Vertical/Tower type AC's of capacity 3.0 TR complete all as specified and directed.
S&F in renewal of running capacitor combo 50+6 mfd for split type AC's of capacity 1.5/2.0 TR complete all as specified and directed.
S&F in renewal of running capacitor 50 mfd for split type AC's of capacity 1.5/2.0 TR complete all as specified and directed.
S&F in renewal of indoor blower fan motor, single phase, 230 Volt of split type AC Suitable for 1.5 TR capacity complete all as specified and directed.
S&F in renewal of indoor blower fan motor, single phase, 230 Volt of split type AC Suitable for 2.0 TR capacity complete all as specified and directed.
S&F in renewal of burnt compressor of capacity 2.0 TR of split type AC unit and re-fixing the same after renewal from the company make original compressor as per existing Make & Model of rotary type including gas charging complete all as specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the unit quoted rate. (ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
S&F in renewal of burnt compressor of capacity 1.5 TR of split type ACs unit and re-fixing the same after renewal from the company make original compressor as per existing Make & Model of rotary type including gas charging complete all as specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the unit quoted rate. (ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
M&L for repair to leaking area of split type AC unit of capacity 2.0/1.5 TR including dehydration, gas charging of gas R22/R410A/R-32 as applicable, pressure check & testing complete all as specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the unit quoted rate. (ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
S&F in renewal of air filter of indoor unit for split type AC units of capacity 1.5/2.0 TR as per existing Make & Model complete all as specified and directed.
S&F in renewal of insulation for Split AC Copper Tube 5/8 inch with Nitrile rubber insulation tube of OD thickness 10mm and length 6 ft per piece (minimized heat gain and loss, Good condensation control) followed with clamps complete all as specified and directed.
S&F in renewal of insulation for Split AC Copper Tube 1/2 inch with Nitrile rubber insulation tube of OD thickness 10mm and length 6 ft per piece (minimized heat gain and loss, Good condensation control) followed with clamps complete all as specified and directed.
S&F in renewal of insulation for Split AC Copper Tube 1/4 inch with Nitrile rubber insulation tube of OD thickness 10mm and length 6 ft per piece (minimized heat gain and loss, Good condensation control) followed with clamps complete all as specified and directed.
S&F in renewal of 3 core copper PVC insulated FRLSH cable of size 4.0 Sqmm, flexible cables, 1100 Volts and confirming to IS: 694 complete all as specified and directed.
S&F in renewal of suction line (1/4") copper pipe or suitable size as per existing dia and length with Nitrile Rubber protection as required at site complete all as specified and directed.
S&F in renewal of discharge line (5/8") copper pipe or suitable size as per existing dia and length with Nitrile Rubber protection as required at site complete all as specified and directed.
S&F in renewal of discharge line (1/2") copper pipe or suitable size as per existing dia and length with Nitrile Rubber protection as required at site complete all as specified and directed.
S&F in renewal of PCBs indoor/ outdoor units as per existing Make & model for Split type AC of Capacity 2.0 TR/ 1.5 TR complete all as Specified and Directed.
S&F in renewal of Flexible PVC drain pipe of size 15mm bore & suitable for Split type AC of Capacity 1.5/2.0 TR complete all as specified and directed.
S&F in renewal of outdoor unit fan blade as per existing Make and model suitable for Split type AC of Capacity 1.5 TR complete all as Specified and directed.
S&F in renewal of outdoor unit fan blade as per existing Make and model suitable for Split type AC of Capacity 2.0 TR complete all as Specified and directed.
S&F in renewal of outdoor unit condenser fan motor as per existing Make & model suitable for 1.5 TR capacity air conditioner complete all as specified and directed.
S&F in renewal of outdoor unit condenser fan motor as per existing Make & model suitable for 2.0 TR capacity air conditioner complete all as specified and directed.
M&L for shifting of Split AC's of capacity 1.5/2.0 TR with indoor, outdoor including all connected accessories after pumping down the gas and , refitting, topping up the gas, testing and commissioning complete all as specified and directed.
S F in renewal of brass flare nut 5/8 inch (Pack of 4) for gas pipe line connection both in 1.5/2.0 TR capacity of Split Type AC complete all as specified and directed.
S&F in renewal of brass flare nut 1/2 inch (Pack of 4) for gas pipe line connection both in 1.5/2.0 TR capacity of Split Type AC complete all as specified and directed.
S&F in renewal of brass flare nut 1/4 inch (Pack of 4) for gas pipe line connection both in 1.5/2.0 TR capacity of Split Type AC complete all as specified and directed.
M&L for repair / servicing of existing UPS incuding dismantling electric connection and cleaning of realy junction point, connection & testing of UPS including replacement of U/S part of 05 KVA complete all as specified and directed. Note :- (a) Minor item / spares parts shall deemed to be included in the unit quoted rate & not to be paid separtely .
S&F in renewal of single pole and neutral sheet metal enclosure with a two pin and earth plug and socket and including one MCB SPN 20 Amp, 240 Volt, MCB, 'C' curve type with AC box, rupturing capacity 10 KA complete all as specified and directed.
S&F in renewal of MCB single pole 6 to 32 Amp, 'C' curve having rupturing capacity 10 KA conforming to IS-8828-1996, IEC-60898, complete all as specified & directed.
S&F in renewal of metal clad plug 2P+E for all type of AC's as per existing Make and size complete all as specified & directed.
S&F in renewal of metal clad socket 2P+E for all type of AC's as per existing Make and size complete all as specified & directed.
M/S SOLANKI GENERAL SUPPLIERS
vinayandsons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .