Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹5.2 LAccepted-Finance | L-1 | Accepted-Finance Admitted | |
| 2 | L-2₹6.4 L+₹1.1 L (21.9%)Accepted-Finance | L-2 | Accepted-Finance Admitted | |
| 3 | L-3₹6.8 L+₹1.5 L (29.4%)Accepted-Finance | L-3 | Accepted-Finance Admitted | |
| 4 | L-4₹8.0 L+₹2.7 L (52.5%)Accepted-Finance | L-4 | Accepted-Finance Admitted | |
| 5 | L-5₹8.3 L+₹3.1 L (58.9%)Accepted-Finance AASHIYANA SECTOR N 304 KILA CHAURAHA KANPUR ROAD AASHIYANA LUCKNOW UTTAR PRADESH 226012 | LUCKNOW | UTTAR PRADESH | 226012 | L-5 | Accepted-Finance Admitted |
Tender Value
₹9.9 L
EMD Value
₹10,000
Closing Date
9 Jan 2023, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Electricity Transmission Circle, 220 KV S/S Campus Natwa, Mirzapur
Shifting of old, damaged and unused 02 Nos. 12.5 MVA T/Fs and 20 MVA T/F from switchyard and erection and commissioning of 2 Nos. 40MVA T/F (New) in place of running 2 Nos. 20 MVA, l32/33KV NGEF make T/F (in terms of increasing capacity) along with a
2022_UPTCL_759306_1
51/2022-23/ETC/Mzp
Open Tender
Electrical Works
Fixed-rate
60 days
Chauri
As per tender specification
2 documents required · 2 mandatory
₹590
Executive Engineer, ETD, Mirzapur
₹10,000
22 Mar 2023
15 Dec 2022
10 Jan 2023
15 Dec 2022
9 Jan 2023
15 Dec 2022
Amount
Shifting of 03 N0s. main tank of Transformers [ 01 No. 20 MVA T/F Bharat Bijlee make (Damaged) and 02 No. 12.5 MVA T/F HHE make (old & used) ] from Switchyard to open store plinth distance 100 mtr (approx.) with the help of rail, pulley device, slippers etc. including turning of tank, if required, including all T&P and work required to complete the job satisfactorily @ 5 Meter/job at 132KV S/S, Chauri. 100»5= 20, 3x20= 60 Job
Opening of jumpers, cutting of earthing and opening of cable connection of RTCC panels, re-termination along with re-glanding and re-ferruling as per new cable schedule etc., of 2 no. 20MVA T/F including all T&P.
Dismantling of 132/33KV 20MVA T/F, drain out T/F oil in to oil drums up to required level, removal of all radiators, conservator tank, oil pipe line, HV/LV and neutral bushing, fan, and marshaling box etc. blanking main tank radiators, oil pipe lines, conservator tank, providing proper gasket along with nut and bolts etc. including all T&P.
Shifting of 02 No. 20 MVA T/F from plinth to safe place (up to 20 Meter Distance approx) including turning of tank if required, including all T&P and work required to complete the job satisfactorily at 132KV S/S, Chauri. @ 5 mtr/Job 20»5=4, 2x4= 8Job
Additional shifting of 02 No. 20 MVA T/F for 80 Meter (@ 5 Meter/job) at l32KV S/S, Chauri, if required. 80»5= 16, 2x16=32 Job
Shifting of main tank of 02 No. 40 MVA T/F from unloading place to plinth (up to 20 Meter Distance) with the help of rail, pulley device, slippers etc. including turning of tank, if required, including all T&P and work required to complete the job satisfactorily at 132KV S/S, Chauri
Additional shifting of 02 No. 40 MVA T/F for 50 Meter (@ 5 Meter/job) at 132KV S/S, Chauri, if required. 50»5=10, 2x10= 20Job
Complete Erection of 02 Nos. 40MVA T/F by erection of radiators, conservator tank, all bushing with their turrets, connecting oil pipe, cooling fans, motor drive mechanism with tap changer, RTCC panel, and associated oil pipe line etc. to complete the job satisfactorily, including first filling of oil and topping up of T/F oil in tank, radiator pipe lines, conservator tank etc. and attending oil leakage, if any and all other associated work for satisfactory completion of work along with arrangement of labours and T&P with operations to complete the job in all respect.
Centrifuging of complete T/F oil in T/F & Tank by connecting Centrifuging pipes, circulating the T/F oil through centrifuging machine to be provided by the contractor & taking the BDV value of the oil periodically till the required value is achieved as per direction of supervising engineer, all T&P, labour, and centrifuging machine shall be provided by the contractor.
Complete earthing of erected 2x40 MVA T/F as per standard practice using 75x10mm. M.S. flat, main tank of the T/F, marshaling box, drive mechanism of cooling fan etc. shall be earthed as per standard practice(MS flat shall be provided by contractor and earthing electrodes shall be provided by the department )
Earthing of 2x40 MVA T/F neutral bushing with using 75x10mm. M.S. flat run old ladder, its grounding, painting connecting with delta with at two points and other associated works (MS flat shall be provided by contractor and earthing electrodes shall be provided by the department), the above also includes painting of earthing strip with one coat of red oxide primer and two coat of bus green synthetic enameled paint.
Delta earthing of 2x40 MVA T/F HV/LV neutral bushing with using 75x10mm. M.S. flat (MS flat shall be provided by contractor and earthing electrodes shall be provided by the department), the above also includes painting of earthing strip with one coat of red oxide primer and two coat of bus green synthetic enameled paint.
Jumpering of 40MVA T/F of HV side with single ACSR Panther Conductor
Jumpering of 40MVA T/F of LV side with single ACSR Moose Conductor
Laying of following size control cables in the cable trenches from control panel to marshaling boxes /equipment / junction boxes etc. in switch-yard for new 40 MVA T/F as per cable schedule along with saddling at every 750 mm distance with MS saddles of size 25x3mm including carriage of cable drums from store to laying site and shifting back to store after completion of work and termination of new control cables for 40 MVA T/F from control and relay panel to marshaling box / equipment / JB etc. for new 40MVA T/F as per cable schedule and inter-connection with control cable at marshaling box and OLTC panel to RTCC panel FCC to each fan with feruling and dressing and associated work to complete the job satisfactorily as per technical specification.
2 core x 2.5mm2 unarmored
4 core x 2.5mm2 unarmored
6 core x 2.5mm2 unarmored
Erection of 132 KV Transformer C&R panel for 40 MVA T/F as per instruction manual including its shifting from store to site of job, termination of control cable inside newly erected and grouted l32KV C&R panel including glanding, feruling etc. as per drawing schedule, including other associated work to complete the job satisfactory.
Proper packing of HV/LV bushing including proper wrapping with potythene /paper sheets in the wooden crated got emptied after taking out bushing of 2x20 MVA T/F.
Dismantling of 120 KV LA, opening of jumpers, cutting of earthing etc., re-erection of l20KV LA and related associated works to complete the job satisfactorily in all respect.
Dismantling of 30 KV LA, opening of jumpers, cutting of earthing etc., re-erection of 30KV LA and related associated works to complete the job satisfactorily in all respect.
Dismantling of 33 KV Old CTs of CTR 400-200/1-1A & erection of new 33 KV new CTs with CTR 800-400/1-1 A, setting the CTR on 800/1A, cable termination, shorting; including earthing of the instrument, shifting of the CTs; to be erected from store to site and dismantled from site to store and all related work to complete the job satisfactorily in all respect.
SHILPA ENTERPRISES
R.K.ENGINEERING SERVICES
M/S ACCURATE ENGINEERING
SMV POWER SOLUTION
Hi-tech power transmission
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .